J041--Air Balancing Testing WRJ VAMC
Closed Solicitation Posted
- Solicitation number
- 36C24124Q0514
- Agency
-
Veterans Integrated Service Network 1
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- PSC
- J041 Maint/Repair/Rebuild Of Equipment- Refrigeration, Air Conditioning, And Air Circulating Equipment
- Place of performance
- See SOW.
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration is seeking air balancing testing services for the White River Junction VA Medical Center. The contractor will be required to measure supply and return CFM, room pressures, and air changes per industry standards detailed in the Statement of Work. Quotes will be evaluated on price, past performance, and technical approach, with the Government awarding to the responsible offeror whose quote is most advantageous. Quotes are due by May 28, 2024 at 3:00 PM EST and should be emailed to the point of contact, David Valenzuela.
This solicitation is a Service-Disabled Veteran-Owned Small Business set-aside with a NAICS code of 238220 - Plumbing, Heating, and Air-Conditioning Contractors. The government intends to award a firm-fixed price contract for a base year plus up to four option years. The place of performance is the 180 Montgomery St, San Francisco, CA 94104 location of the White River Junction VA Medical Center. No details on potential award values or budget ranges were provided.
Notice text
2 versions
Update #2 · Latest ·
The purpose of this amendment is to:
1. Upload all questions asked and their subsequent answers. Please see attachment labeled Questions and Answers and attachment 405 S Att 1 Room Spreadsheet Critical Highlights .
2. Extend the Quote due date to 28 May 2024 at 3:00 PM EST. Quotes must be emailed to David Valenzuela at david.valenzuela2@va.gov.
Update #1 ·
Please see attachment labeled Combined Synopsis-Solicitation .
Files
| File | Type | Posted |
|---|---|---|
| 405 S Att 1 Room Spreadsheet Critical Highlights.xlsx | XLSX spreadsheet | |
| Questions and Answers.docx | DOCX document | |
| 36C24124Q0514_2.docx | DOCX document | |
| Combined Synopsis-Solicitation.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| J041--Air Balance Testing Services White River Junction VAMC | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| F108--657A4-21-800 - VPIH Services for Remove and Replace End of Life Heating, Ventilation and Air Conditioning Construction | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business | |
| 648-22-104 Correct HVAC Deficiencies (P&V) | Veterans Integrated Service Network 20 | Service-Disabled Veteran-Owned Small Business | |
| 4120--rental of two chillers for one year | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--Local | 460-26- 4-5074-0108 | 460-26-999 | Condenser Water Piping Modification | (VA-26-00077929) | Veterans Integrated Service Network 4 | Service-Disabled Veteran-Owned Small Business | |
| J042--Fire Alarm, Suppression Systems, and Hood Testing, Inspection, and Certification Services - SAVAHCS | Veterans Integrated Service Network 22 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity