Hotbox Testing for Additively Constructed Reinforced Concrete Structures with Integrated Energy Efficiency

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
W9132T24Q0011
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Champaign, Illinois 61826, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Army Engineer Research and Development Center (ERDC) Construction Engineering Research Laboratory (CERL) seeks hotbox testing services for an additively constructed reinforced concrete wall specimen measuring approximately 68 inches wide by 60 inches tall by 15 inches deep and weighing 3,500 pounds. The contractor must test the upright specimen in a hotbox apparatus according to ASTM C1224 standards to evaluate its thermal performance. Responses for this request for quotation are due by February 20, 2024.

There is no set-aside designation for this requirement. The NAICS code is 541380 for testing laboratories and services. The specimen must be tested in a hotbox apparatus at the CERL location in Champaign, Illinois. Key numerical details include the specimen dimensions of 68 inches wide by 60 inches tall by 15 inches deep and weight of 3,500 pounds.

Notice text

This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. 

The solicitation number is W9132T24Q0011 and is being issued as a Request for Quotation (RFQ).

The U.S. Army Engineer Research and Development Center (ERDC), Construction Engineering Research Laboratory (CERL) has a requirement to conduct thermal testing by Means of a Hot Box Apparatus and ASTM C1224 Standard Test for thermal performance of building materials and envelope assemblies on an additively constructed wall specimen that is roughly 68 inches wide by 60 inches tall by no more than 15 inches in depth. The specimen weight will be approximately 3,500 lbs. and must be tested standing upright in the Hotbox Apparatus. The specimen will contain steel reinforcement, air gaps, and foam insulation in addition to concrete.

The associated North American Industry Classification System (NAICS) code is 541380 — Testing Laboratories and Services, Size Standard: $19.0 Million. 

Please reference the attached written RFQ for full detail of the requirement as well as all applicable provisions and clauses.

Please provide responses to this notice no later than the date and time listed above to:

CERL-CT-QUOTES@usace.army.mil

Telephone responses will not be accepted.

Files

File Type Posted
W9132T24Q0011.pdf PDF

Notice history

Notice Type Posted
Hotbox Testing for Additively Constructed Reinforced Concrete Structures with Integrated Energy Efficiency Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Request for Information for On-Site Fabrication and Assembly of a Three-Bay High-Performance Magazine (HPM) Structure Fort Polk, Louisiana 71459, United States · NAICS 238120 Engineer Research and Development Center No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity