Generators and generator sets, electrical.
Award Notice Posted
- Solicitation number
- W56HZV14R0022
- Agency
-
ACC Warren
Army Contracting Command, Department of Defense
- Awarded
- to American Electrical Enterprises Inc.
- Set-aside
- Total Small Business
Opportunity facts
- Contract number
- W56HZV15D0079 Federal IDV award
- NAICS code
- 334515 Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
- PSC
- Not on record
- Place of performance
- U.S. Army Contracting Command, Warren, Michigan 48397 48397 USA
Notice details come from SAM.gov. Updated .
Notice text
6 versions
Update #6 · Latest ·
PLEASE BE ADVISED: THE U.S. ARMY WILL BE REQUESTING PROPOSALS FOR PORTABLE LOAD BANKS TO SUPPORT MILITARY GENERATOR SET MAINTENANCE. THE IDEAL CANDIDATE WILL NOT EXCEED 84 POUNDS IN WEIGHT (DO NOT COUNT CABLES AND SHIPPING CASE). THE LOAD BANK WILL SUPPORT 60HZ, THREE PHASE GENERATORS 5KW THROUGH 60KW.THE LOAD BANKS SHOULD HAVE CONTROLS AND STATUS INDICATORS THAT DISPLAY VOLTAGE, CURRENT, FREQUENCY AND POWER. THE LOAD BANK SHOUD ALSO HAVE A SAFETY SYSTEM THAT PROTECTS FROM OVERLOADING AND OVERHEATING. THE LOAD BANK CAN UTILIZE POWER FROM THE GENERATOR FOR COOLING OR A 120VAC EXTERNAL POWER CIRCUIT. THE LOAD BANK WILL HAVE A QUICK DISCONNECT CABLING SYSTEM THAT DOES NOT REQUIRE TOOLING TO CONNECT OR DISCONNECT. PLEASE REFER TO SOLICITATION NUMBER W56HZV14R0022. THE POINT OF CONTACT IS MS. ROSIE CLAY. THIS SOLICITATION WILL BE RELEASED ON OR ABOUT 2014MAY01. THE SOLICITATION WILL CONTAIN ALL INFORMATION NECESSARY FOR SUBMITTING PROPOSALS. PLEASE DO NOT SUBMIT PROPOSALS ! UNTIL THE SOLICITATION IS RELEASED. THANK YOU..
Update #5 ·
Added: Feb 18, 2014 4:15 pm Modified: Jan 14, 2015 8:42 amTrack Changes PLEASE BE ADVISED: THE U.S. ARMY WILL BE REQUESTING PROPOSALS FOR PORTABLE LOAD BANKS TO SUPPORT MILITARY GENERATOR SET MAINTENANCE. THE IDEAL CANDIDATE WILL NOT EXCEED 84 POUNDS IN WEIGHT (DO NOT COUNT CABLES AND SHIPPING CASE). THE LOAD BANK WILL SUPPORT 60HZ, THREE PHASE GENERATORS 5KW THROUGH 60KW.THE LOAD BANKS SHOULD HAVE CONTROLS AND STATUS INDICATORS THAT DISPLAY VOLTAGE, CURRENT, FREQUENCY AND POWER. THE LOAD BANK SHOUD ALSO HAVE A SAFETY SYSTEM THAT PROTECTS FROM OVERLOADING AND OVERHEATING. THE LOAD BANK CAN UTILIZE POWER FROM THE GENERATOR FOR COOLING OR A 120VAC EXTERNAL POWER CIRCUIT. THE LOAD BANK WILL HAVE A QUICK DISCONNECT CABLING SYSTEM THAT DOES NOT REQUIRE TOOLING TO CONNECT OR DISCONNECT. PLEASE REFER TO SOLICITATION NUMBER W56HZV14R0022. THE POINT OF CONTACT IS MS. ROSIE CLAY. THIS SOLICITATION WILL BE RELEASED ON OR ABOUT 2014MAY01. THE SOLICITATION WILL CONTAIN ALL INFORMATION NECESSARY FOR SUBMITTING PROPOSALS. PLEASE DO NOT SUBMIT PROPOSALS ! UNTIL THE SOLICITATION IS RELEASED. THANK YOU.
Update #4 ·
PORTABLE LOAD BANK, POWER CABLES, AND ACCESSORIES; FIVE YEAR REQUIREMENT CONTRACT WITH QUANTITY OF 2 PRODUCT VERIFICATION TEST UNITS (PVT) AND 2,294 PRODUCTION UNITS; USED BY MILITARY OCCUPATION SPECIALITY (MOS) 91D - POWER GENERATION EQUIPMENT REPAIRER DURING MAINTENANCE AND REPAIR OF TACTICAL ELECTRIC GENERATORS; SMALL BUSINESS SET ASIDE; SOLICITATION WILL CLOSE ON OR ABOUT JANUARY 12, 2015..
Update #3 ·
Added: Feb 18, 2014 4:15 pm Modified: Nov 21, 2014 9:51 amTrack Changes PORTABLE LOAD BANK, POWER CABLES, AND ACCESSORIES; FIVE YEAR REQUIREMENT CONTRACT WITH QUANTITY OF 2 PRODUCT VERIFICATION TEST UNITS (PVT) AND 2,294 PRODUCTION UNITS; USED BY MILITARY OCCUPATION SPECIALITY (MOS) 91D - POWER GENERATION EQUIPMENT REPAIRER DURING MAINTENANCE AND REPAIR OF TACTICAL ELECTRIC GENERATORS; SMALL BUSINESS SET ASIDE; SOLICITATION WILL CLOSE ON OR ABOUT JANUARY 12, 2015.
Update #2 ·
PLEASE BE ADVISED: THE U.S. ARMY WILL BE REQUESTING PROPOSALS FOR PORTABLE LOAD BANKS TO SUPPORT MILITARY GENERATOR SET MAINTENANCE. THE IDEAL CANDIDATE WILL NOT EXCEED 84 POUNDS IN WEIGHT (DO NOT COUNT CABLES AND SHIPPING CASE). THE LOAD BANK WILL SUPPORT 60HZ, THREE PHASE GENERATORS 5KW THROUGH 60KW.THE LOAD BANKS SHOULD HAVE CONTROLS AND STATUS INDICATORS THAT DISPLAY VOLTAGE, CURRENT, FREQUENCY AND POWER. THE LOAD BANK SHOUD ALSO HAVE A SAFETY SYSTEM THAT PROTECTS FROM OVERLOADING AND OVERHEATING. THE LOAD BANK CAN UTILIZE POWER FROM THE GENERATOR FOR COOLING OR A 120VAC EXTERNAL POWER CIRCUIT. THE LOAD BANK WILL HAVE A QUICK DISCONNECT CABLING SYSTEM THAT DOES NOT REQUIRE TOOLING TO CONNECT OR DISCONNECT. PLEASE REFER TO SOLICITATION NUMBER W56HZV14R0022. THE POINT OF CONTACT IS MS. ROSIE CLAY. THIS SOLICITATION WILL BE RELEASED ON OR ABOUT 2014MAY01. THE SOLICITATION WILL CONTAIN ALL INFORMATION NECESSARY FOR SUBMITTING PROPOSALS. PLEASE DO NOT SUBMIT PROPOSALS ! UNTIL THE SOLICITATION IS RELEASED. THANK YOU..
Update #1 ·
Added: Feb 18, 2014 4:15 pm PLEASE BE ADVISED: THE U.S. ARMY WILL BE REQUESTING PROPOSALS FOR PORTABLE LOAD BANKS TO SUPPORT MILITARY GENERATOR SET MAINTENANCE. THE IDEAL CANDIDATE WILL NOT EXCEED 84 POUNDS IN WEIGHT (DO NOT COUNT CABLES AND SHIPPING CASE). THE LOAD BANK WILL SUPPORT 60HZ, THREE PHASE GENERATORS 5KW THROUGH 60KW.THE LOAD BANKS SHOULD HAVE CONTROLS AND STATUS INDICATORS THAT DISPLAY VOLTAGE, CURRENT, FREQUENCY AND POWER. THE LOAD BANK SHOUD ALSO HAVE A SAFETY SYSTEM THAT PROTECTS FROM OVERLOADING AND OVERHEATING. THE LOAD BANK CAN UTILIZE POWER FROM THE GENERATOR FOR COOLING OR A 120VAC EXTERNAL POWER CIRCUIT. THE LOAD BANK WILL HAVE A QUICK DISCONNECT CABLING SYSTEM THAT DOES NOT REQUIRE TOOLING TO CONNECT OR DISCONNECT. PLEASE REFER TO SOLICITATION NUMBER W56HZV14R0022. THE POINT OF CONTACT IS MS. ROSIE CLAY. THIS SOLICITATION WILL BE RELEASED ON OR ABOUT 2014MAY01. THE SOLICITATION WILL CONTAIN ALL INFORMATION NECESSARY FOR SUBMITTING PROPOSALS. PLEASE DO NOT SUBMIT PROPOSALS ! UNTIL THE SOLICITATION IS RELEASED. THANK YOU.
Files
| File | Type | Posted |
|---|---|---|
| ATT0002.doc | DOC document | |
| ATT0004.doc | DOC document | |
| ATT0005.doc | DOC document | |
| ATT0001.doc | DOC document | |
| ATT0010.xlsx | XLSX spreadsheet | |
| ATT0007.doc | DOC document | |
| ATT0006.doc | DOC document | |
| ATT0008.pdf | ||
| ATT0009.pdf | ||
| ATT0003.doc | DOC document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Miscellaneous electric power and distribution equipment | Award Notice | |
| This notice | Award Notice | |
| Load Banks to support military generator set maintenance. | Award Notice |