Electric On-Demand Tankless Water Heater
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- W911S225U0955
- Agency
-
MICC Fort Drum
Mission and Installation Contracting Command, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 332510 Hardware Manufacturing
- PSC
- 4520 Space And Water Heating Equipment
- Place of performance
- Usag Ft Hunter Liggett 93928
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Army Materiel Command Mission and Installation Contracting Command Fort Drum is procuring electric on-demand tankless water heaters for point-of-use applications. The solicitation requires commercial-grade water heaters with specific technical specifications including 48,000 watts, 57.8 amps, 480V three-phase power, and a minimum flow activation of 1 gallon per minute. The units must operate within a temperature range of 100 to 140 degrees Fahrenheit, feature 1 1/4 inch NPT water connections, and provide various temperature rise capabilities at different flow rates ranging from 54 degrees at 6.0 GPM to 218 degrees at 1.5 GPM. Additional requirements include vertical mounting orientation, digital display with keypad, maximum flow rate of 40 GPM, and 6AWG wire conductor gauge. The solicitation posted on June 18, 2025, with responses due by June 27, 2025, and successful contractors must provide product brochures and manuals upon award and ship within five business days.
This procurement opportunity is designated as a Total Small Business set-aside, limiting competition to qualified small business entities. The contract falls under NAICS code 332510 for Hardware Manufacturing and PSC code 4520 for Space and Water Heating Equipment. Performance will take place at Fort Hunter Liggett, California 93928. The solicitation does not specify award values, quantities of units required, or identify any incumbent contractors. The tight timeline between posting and response deadline, coupled with the five-day shipping requirement, indicates an urgent operational need for the military installation.
Notice text
3 versions
Update #3 · Latest ·
Amended implemented to change NAICS code from 423720 to 332510 and add another day to solicitation to provide adequate time for the change. Electric Tankless Water Heater Point-of-Use Water Heater Application General Purpose Commercial Watts - Water Heaters 48 000 W Amps - Water Heaters 57.8 A Voltage - Water Heaters 480 Min Flow Activation 1 gpm Phase - Water Heaters 3 Temp Range - Water Heaters 100 Degrees to 140 Degrees F, Water Connection 1 1/4 in NPT Temp Rise @ 1.5 GPM 218 Degrees F Temp Rise @ 6.0 GPM 54 Degrees F Temp Rise @ 2.5 GPM - Water Heaters 131 Degrees F Temp Rise @ 4.0 GPM 81 Degrees F. Operating Voltage 480V AC, Cord Conductor Gauge 6AWG Wire, Amp Per Phase 58, Mounting Orientation Vertical, Digital Display with Keypad. Maximum Flow Rate 40gpm. Cold Inlet Size 1 1/4in, Overall Depth 10.28, Overall Height 17.61in, Overall Width 26.17in, Default Temperature 120 degrees F.Standard ANSI Z358.1; cETLus IntertekPlease provide Brochure and Product Manual once awarded be able to ship within 5 business days
Update #2 ·
Electric Tankless Water Heater Point-of-Use Water Heater Application General Purpose Commercial Watts - Water Heaters 48 000 W Amps - Water Heaters 57.8 A Voltage - Water Heaters 480 Min Flow Activation 1 gpm Phase - Water Heaters 3 Temp Range - Water Heaters 100 Degrees to 140 Degrees F, Water Connection 1 1/4 in NPT Temp Rise @ 1.5 GPM 218 Degrees F Temp Rise @ 6.0 GPM 54 Degrees F Temp Rise @ 2.5 GPM - Water Heaters 131 Degrees F Temp Rise @ 4.0 GPM 81 Degrees F. Operating Voltage 480V AC, Cord Conductor Gauge 6AWG Wire, Amp Per Phase 58, Mounting Orientation Vertical, Digital Display with Keypad. Maximum Flow Rate 40gpm. Cold Inlet Size 1 1/4in, Overall Depth 10.28, Overall Height 17.61in, Overall Width 26.17in, Default Temperature 120 degrees F.Standard ANSI Z358.1; cETLus IntertekPlease provide Brochure and Product Manual once awarded be able to ship within 5 business days
Update #1 ·
Electric Tankless Water Heater Point-of-Use Water Heater Application General Purpose Commercial Watts - Water Heaters 48 000 W Amps - Water Heaters 57.8 A Voltage - Water Heaters 480 Min Flow Activation 1 gpm Phase - Water Heaters 3 Temp Range - Water Heaters 100 Degrees to 140 Degrees F, Water Connection 1 1/4 in NPT Temp Rise @ 1.5 GPM 218 Degrees F Temp Rise @ 6.0 GPM 54 Degrees F Temp Rise @ 2.5 GPM - Water Heaters 131 Degrees F Temp Rise @ 4.0 GPM 81 Degrees F. Operating Voltage 480V AC, Cord Conductor Gauge 6AWG Wire, Amp Per Phase 58, Mounting Orientation Vertical, Digital Display with Keypad. Maximum Flow Rate 40gpm. Please provide Brochure and Product Manual once awarded be able to ship within 5 business days
Notice history
| Notice | Type | Posted |
|---|---|---|
| Electric On-Demand Tankless Water Heater | Award Notice | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Electrically Heated Tank | MICC Fort Drum | Total Small Business | |
| Heater, water, electric | Construction and Equipment | Total Small Business | |
| Heater, water, electric | Construction and Equipment | HUBZone | |
| Heater, water, electric | Construction and Equipment | No set-aside | |
| 657-27-107JC, Replace Select Hot Water Heating System | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business Sole Source |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity