Notice text
Added: May 09, 2017 8:16 am
Source Sought Notification
The Regional Health Contracting Office - Central is issuing this Sources Sought Notice on behalf of San Antonio Military Medical Center, JBSA - Fort Sam Houston, Texas. Any responses to this Sources Sought Notice will be used for planning purposes only. Based on the responses to this notice, the requirement may be set-aside for small businesses, procured through full-and-open competition, or result in a sole-source contract. This notice is not a solicitation of offers, nor is it a notice to proceed.
The San Antonio Military Medical Center (SAMMC) Cardiovascular Procedures Services have a requirement for Biosense Webster catheters which are compatible with the CARTO3 System and Software currently owned by BAMC, Cardiovascular Procedures Service, at San Antonio Military Medical Center Main Cardiovascular Department (on JBSA - Fort Sam Houston)
1) Organization name, address, e-mail address, Web site address, telephone number, and size (small versus large business, and any other socio-economic categories) and type of ownership for the organization;
2) Tailored capability statements addressing the salient characteristics listed, with appropriate documentation supporting capability.
a. The catheters must interface directly with the existing Biosense Webster CARTO3
System
b. The catheters must allow the operator to perform fast anatomical mapping (FAM) and
allow for instantaneous catheter localization with accuracy of +/- 1mm. All catheters
manufactured by Biosense Webster are proprietarily manufactured for compatibility and
use with the CARTO3 System for diagnostic, ultrasound, and therapeutic purposes.
c. The catheters must be sensor based and allow for fast anatomical map development with
map activation and voltage data collection.
d. These catheters are regular expendable proprietary items which are fundamentally
designed to interface via direct connection with the Biosense Webster CARTO3 System
Patient Interface Unit (PIU).
e. The inherent design of the Multi electrode mapping catheters must be linked to CARTO
MEM proprietary software of the CARTO3 system, which allows for the simultaneous
acquisition of up to 20 highly accurate activation points (point-to-point map) for
maximized speed, accuracy and efficiency in mapping complex atrial and ventricular
circuits.
f. The Soundstar ultrasound catheters must provide the ability to visualize and mark cardiac
anatomy through the CARTO3 System and afford the ability to visualize the tip of the
ablation catheter via the ultrasound image using the tip to tissue overlay feature.
g. The ablation catheters must be capable of a direct interface with the CARTO SmartTouch
Catheter ablation System and able to receive continuous peristaltic pumping heparinized irrigation solution, and variable power delivery in conjunction with this proprietary system.
h. The SmartTouch Catheters must provide force contact parameters and visitag integration
with the CARTO3 System reflecting real time force contact information and ablation characteristics
that better inform the physician's ablation strategy and delivery of lesion set which are
designed for use with the CARTO3 System and SmartAblate Generator System.
THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this notice is purely voluntary; the Government assumes no financial responsibility for any costs incurred.
Submission Instructions: Interested parties who consider themselves qualified to provide the above listed catheters are invited to submit a response to this Sources Sought Notice by 12:00 p.m. CST,
May 19 2017. All responses must be emailed to roland.jasso.civ@mail.mil and michelle.m.bartkowski.civ@mail.mil.
Notice history
| Notice | Type | Posted |
|---|---|---|
| Cardiaxx Catherters Compatible with the Carto XP EP System | Award Notice | |
| catheters that are compatible with the CARTO3 System and Software | Award Notice | |
| This notice | Award Notice |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity