C1DA--402-22-750 A/E Renovate Sterile Processing
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 36C24122R0077
- Agency
- Veterans Integrated Service Network 1 Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 541330 Engineering Services
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration VISN 1 is soliciting proposals from architectural and engineering firms for renovation services at the VA Maine Healthcare System facility in Togus, Maine. The solicitation seeks design and construction phase support to renovate 8,400 square feet of the Sterile Processing Department and modernize two connecting dumbwaiters. Proposals will be evaluated based on professional qualifications, healthcare facility experience, past performance, and proximity to Togus. The submission deadline for responses is May 31, 2022.
There is no set-aside designation for this procurement. The primary NAICS code is 541310 and PSC code R425. The budget for the project is estimated between $5-10 million. Key requirements include following all applicable building codes and VA design standards, with a 240 day period of performance for design and a 510 day period for construction administration. The place of performance will be the VA facility located in Togus, Maine.
Notice text
Scope of Work: 402-22-750 Date: Dec. 3, 2021
VAME Togus ME Sterile Processing Department Renovation
Project Summary: VAME Togus ME Sterile Processing Department (SPD) renovation consist of 8,400 GSF in building 200E on the first floor, and two dumbwaiters which transport SPD carts from/to the third floor Surgical Services. Please see Enclosure (1) for the location map. For the renovation no additional area is available. This is an upgrade of all parts of the space and services. Some of the systems and equipment shall be re-used as they are very new, also the dumb waiter locations shall not be changed. The air handling unit AH-6 is new, the AE firm to confirm capacity for use. The design of the SPD shall meet all VA SPD requirements including the Sterile Processing Service and Logistics Service Design Guide, and VA TIL requirements. The total product flow utilizing this GSF shall be determined and compared to the VA requirements. SPD Presently uses Centrak for temp/humidity monitoring. Users have indicated this is useful for trending data, but not ideal for alerting for out-of-range parameters; desire is to have display screen showing room pressure, temp, humidity, and issue live alarms for out-of-range parameters possible link to BMS to notify HVAC personnel. Spaces use ball in wall pressure indications and request continuation of the Ball in Wall indications as back up to the monitoring system.
Attachments
| File | Type | Posted |
|---|---|---|
| 36C24122R0077_1.docx | DOCX document | |
| 402-22-750 AE Supplement C.doc | DOC document | |
| 402-22-750 AE Supplement B.doc | DOC document | |
| 402-22-750 AE Supplement A.doc | DOC document | |
| 402-22-750 AE SOW.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| C1DA--402-22-750 A/E Renovate Sterile Processing | Award Notice | |
| C1DA--402-22-750 A/E Renovate Sterile Processing | Solicitation | |
| C1DA--402-22-750 A/E Renovate Sterile Processing | Special Notice | |
| C1DA--402-22-750 A/E Renovate Sterile Processing | Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity