The Department of Veterans Affairs Veterans Integrated Service Network 22 is issuing a Sources Sought Notice and Request for Information on a Roam 2-Compartment Aluminum Supply Cart, with responses due by May 15, 2026; this is market research only and does not constitute a solicitation. The VA seeks information from potential sources capable of providing four units designed for Endoscopic Retrograde Cholangiopancreatography (ERCP) procedure supplies and accessories.

The solicitation will be unset. NAICS code 339113 (Surgical Appliance and Supplies Manufacturing) applies, with a size standard of 800 employees. Delivery is to VA San Diego Healthcare System, 3350 La Jolla Village Drive, San Diego, California 92161.

Required specifications include lightweight aluminum composite construction, adjustable shelves, dividers, and bins, a hutch and pegboard with a minimum of twelve 4–6" hooks, compatibility with 3", 6", and 9" height trays, a roll-top door with key lock, lockable casters, powder coat paint finish, and non-porous surfaces cleanable with CaviWipes. The cart must fit through standard 43"W x 82"H doorways and provide clear forward visibility with ergonomic access for staff.

Prospective vendors must address 19 specific questions regarding manufacturing or distribution role, business size status, compliance with limitations on subcontracting, commercial-off-the-shelf applicability, Buy American Act conformance, lead times, FDA clearance, leasing options, and existing federal contracts (FSS/GSA/BPA). Pricing information is requested for market research purposes only. Responses should be submitted via email to Hestia.Sim@va.gov. This notice is issued solely for information and planning purposes; responses will inform future acquisition decisions and potential subsequent solicitations.

Notice text

THIS REQUEST FOR INFORMATION (RFI) /Â SOURCES SOUGHT NOTICE IS ISSUEDÂ SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.

SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).

DISCLAIMER

This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

SOURCES SOUGHT/RFI DESCRIPTION

This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 339113 (size standard of 800 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.

The Department of Veterans Affairs (VA) is seeking sources capable of providing four (4) of Roam-2 Compartment Aluminum Supply Cart that have following salient characteristics:

Deliverables:

CLIN

DESCRIPTION

QTY

UOM

0001

ERCP Roll-Top Door Cart w/ Hutch & Pegboard,2-3", 4-6", 2-9" trays with 12-6" Hooks

4

EA

Salient Characteristics

Must be designed for Endoscopic Retrograde Cholangiopancreatography (ERCP) procedure supplies and accessories.

Must be lightweight Aluminum composite construction

Must have adjustable shelves, dividers, and bins that can be repositioned to match specific ERCP sets, such as cannulas, sphincterotomes, stents, balloons, guidewires, contrast, lead aprons, etc.

Must have hutch & pegboard design for ERCP storage needs.

Pegboard must have a minimum of twelve (12) units hooks that are 4 to 6 length.

Pegboard must be the range of 36 to 36 Width and 12 to 16 Height.

Must be customizable so the end users can customize based on procedure needs.

Must be compatible with trays measuring 3 , 6 , and 9 height.

Must come with two (2) 3" height trays

Must come with four (4) 6" height trays

Must come with two (2) 9" height trays with dividers

Must have Roll-top door with a key lock.

Must have casters that are lockable but also allow easy maneuvering in clinic spaces.

Must have a handle to navigate the cart.

Must be with a height that allows staff to maintain clear forward visibility while pushing the cart and enable access to store items without requiring excessive bending or reaching.

Must have overall length and width dimensions that allow it pass through standard facility 43 W x 82 H doorways and hallways and maneuver within treatment rooms, including adequate turning radius clearance

Must be fabricated with all non-porous surfaces.

Must be powder coat paint for easy cleaning and durability.

Must be able to clean with CaviWipes.

Standard Dock Delivery

Place of Performance:

VA San Diego Healthcare System

3350 La Jolla Village Drive

San Diego, CA 92161

The list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required.

If your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:

(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of salient characteristics requirements. For instances where your company cannot meet the salient characteristics requirement(s), please explain. For instances where your company can meet the salient characteristics requirement(s), please show how your company meets/exceeds each requirement.

(2) Please review the list of salient characteristics requirements and provide any additional feedback or suggestions. If none, please reply as N/A.

(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.

(4) Is your company considered small under the NAICS code identified in this RFI?

(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of salient characteristics?

(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).

(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.

(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6?

(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?

(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?

(11) Please indicate whether your product conforms to the requirements of the Buy American Act?

(12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate.

(13) What is estimated life span of your solution? What support/services does that entail?

(14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained.

(15) Does your organization offer a leasing solution? Please elaborate.

(16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).

(17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.

(18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.

(19) Please provide your SAM.gov Unique Entity ID/Cage Code number.

Responses to this notice shall be submitted via email to Hestia.Sim@va.gov. Telephone responses will not be accepted. Responses must be received no later than Friday, May 8, 2026, by 10AM Pacific Local Time.

All responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.

Files

File Type Posted
36C26226Q0780.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
J065--Copy of FY26: MBC Sternudrive LiteTM; Model MBC 709-Modular Department of Veterans Affairs VA Caribbean Healthcare System San Juan PR 00921 · NAICS 339112 Veterans Integrated Service Network 8 No set-aside
6515--Sterilizer Valley Coastal Bend South Texas Veterans Affairs VA Harlingen Healthcare Center Harlingen TX 78550 · NAICS 339112 Veterans Integrated Service Network 17 No set-aside
6515--Smart Hospital Stretchers for the ambulatory procedural unit at the Hudson Valley, Castle Point VAMC. VA Hudson Valley Healthcare System Castle Point VA Medical Center Wappingers Falls NY 12590, United States · NAICS 339113 Veterans Integrated Service Network 2 No set-aside
6670--Gravimetric Scales VA Loma Linda Healthcare System Loma Linda CA 92357, United States · NAICS 334519 Veterans Integrated Service Network 22 No set-aside
6515--Inventory Management System Department of Veterans Affairs VA Phoenix Healthcare System Phoenix AZ 85012 · NAICS 334519 Veterans Integrated Service Network 22 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity