6515--504-20-1-981-0005 Medivators

Closed Solicitation Posted

Solicitation number
36C25720Q0251
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

NAICS code
339112 Surgical and Medical Instrument Manufacturing
PSC
6515 Medical And Surgical Instruments, Equipment, And Supplies
Place of performance
Department of Veterans Affairs Amarillo Vahcs 6010 Amarillo Blvd., W Amarillo, TX 79106

Notice details come from SAM.gov. Updated .

Notice text

The Department of Veterans Affairs, Amarillo, TX is posting this combined Synopsis/Solicitation for Medivators Advantage Plus Automatic Endoscope Preprocessors, through the Contracting Officer in San Antonio, Texas. The government intends to make a contract award to the Lowest Price Technically Acceptable vendor that can provide the required items in accordance to the attached documents, as a result of this solicitation for quotes.

This action is a total small business set-aside for service-disabled veteran owned small business (SDVOSB) only. The NAICS is 339112. Responses to this notice will be used by the Government to make appropriate evaluations and award decisions. Please submit all required information to Ognian Ivanov via e-mail: ognian.ivanov@va.gov by Wednesday , January 29, 2020.

General Requirements : Vendor shall provide 2 each Medivators Advantage Plus Automatic Endoscope Preprocessors as described in the technical requirements below for the Amarillo VA Medical Center at 6010 Amarillo Blvd. West. in Amarillo, TX.

Technical Requirements:

2 each Medivators Advantage Plus Automatic Endoscope Preprocessors that are compatible with current model Medivators Advantage Plus Automatic Endoscope Preprocessors on station.

Asynchronous, dual reprocessing basins

Individual channel connectivity and channel blockage monitoring

Extensive cycle data management for scope-specific cycle programming, operation and cycle data documentation

Utilizes current chemicals Rapicide PA high level disinfectant with Acid and Buffer

Barcode reader and hands free lid operation

Utilizes Advantage Hookup Connector Blocks

Visual display monitor for real-time reprocessing information

Dimensions: 59H x 45W x 36D, Weight: 400lbs, Electrical 100-240 VAC ± 10%: single phase, 50/60HZ; 1000 watts

Water Supply: Minimum flow rate: 1.32 GPM (5 LPM) at 35 -87PSI (2.4-6 bar)

Water Temperature: 35°C ± 2°C; Water hardness: less than 12 gpg (200ppm)

Pre-filter water filters

Basin Size 19W x 17L x 7D inch

Each AER will have an independent air compressor and vapor management system

De-install of current AER s and install of replacement AER s.

The vendor must provide a staff inservice following installation and validation of the system.