STATEMENT OF WORK

Overview: Install chain‐link fencing in accordance with applicable regulations and guidelines to provide a secure perimeter around the upper tactical sites. Fencing will tie into existing fence lines on each end and contain one (1) personnel entry/exit gate with pin‐code locks, two (2) personnel exit‐only gates with pin‐code lock, one (1) sliding vehicle access gate, and one (1) double gate swing vehicle access gate. Refer to drawings SK‐2 thru SK7 for layout and details.

Materials:

The materials shall conform to specifications, applicable industry codes and standards and the manufacturer’s recommendations, whichever is more stringent. Certificates of compliance and Technical Data Sheets are required for all materials supplied. A list of all chemicals to be used shall be provided prior to the start of work. The list shall state the commercial name, manufacturer’s name, chemical name, and quantity to be used or stored on government property (see Attachment 1, 2).

Details:

Fencing: Consists of approximately 550 foot run (including all access gates) connecting the existing inner fence line on the east side of the facility to the existing inner fence line on the west side of the facility. Wire needs to be 8 feet high constructed of 2 inch galvanized mesh. Entire fence line needs to be topped with minimum 7 gauge tension wire and 3 strands of barbed wire. All pipe needs to be galvanized schedule‐40. Line and terminal posts need to be at least 3 inch with slide gate posts at least 4 inch. The fence is to be installed on low shrub, gravel, and paved surfaces. The fence should be located as shown on SK‐2 and SK‐3. Approximately 200 feet of fencing is to be installed on a 25% grade. The fence needs to be 30 feet away from any raised item or building.

Personnel Entry/Exit Gate: Consists of one (1) four foot wide walk through gate with Locknetics® CM‐ series compatible lock(s) to allow controlled entry and exit. This gate is to be located on the south side of building 20 at the stairwell exit. A post with light will need to be installed and wired at this location.

Personnel Exit Only Gates: Consists of two (2) four foot wide walk through gates each with a Locknetics® CM‐series compatible lock to allow exit only from the controlled area. One gate is to be located on the east side of the facility near the existing vehicle access gate. The second gate will be located on the west side of the facility adjacent to the new double gate swing.

Sliding Vehicle Access Gate: This gate consists of one (1) manual opening sliding gate to close an approximately 21 foot wide opening, Contractor responsible for field verification. This gate will be located at edge of the parking lot on the west side of building 20 where it meets the gravel of the tactical site. This gate will normally be chained and locked closed.

Double‐Swing Vehicle Access Gate: This gate consists of two (2) swinging gates that when closed will meet in the center of the existing road on the west side of building 20, just south‐west of the parking lot. This is a manually opening gate that will normally be chained and locked closed.

Existing Utilities: The area contains underground electrical and communication wiring. Contractor is responsible for contacting CALL BEFORE YOU DIG prior to any work.

Submittals: The Contractor shall submit shop drawings (3 sets minimum) of all material to be purchased and installed for this project for approval prior to any construction.