C5-36 HOSPITAL PAD CONSTRUCTION DETAILS

View the file

Other files for this federal contract opportunity

Other files attached to Hospital Pad, newest first.
File Type Posted
W91ZRS09B0010-0002.doc DOC document
PreBid Conference.pdf PDF
PreBidSiteVisitsigninRoster.pdf PDF
20081566A10DET01HOSPITALPADC533.pdf PDF
20081566A10DET01HOSPITALPADC534.pdf PDF
20081566A10STP01C511HospitalLayout.pdf PDF
20081566A10STP01C500HospitalOverall.pdf PDF
20081566A10STP01C501HospitalDemo.pdf PDF
W91ZRS09B0010-0001.doc DOC document
20081566A10DET01HOSPITALPADC535.pdf PDF
20081566A10DET01HOSPITALPADC532.pdf PDF
HospitalPadAdd1.pdf PDF
20081566A10STP01C512HospitalGrading.pdf PDF
HospitalPadSpecs.pdf PDF
G5-01_Cover.pdf PDF
W91ZRS09B0010.doc DOC document
HospitalPadCDrawings.pdf PDF
Show all 17

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CULTEC RECHARGER 330 XL HD SPECIFICATIONS

GENERAL

CULTEC RECHARGER 330XL CHAMBERS ARE DESIGNED FOR UNDERGROUND STORMWATER MANAGEMENT. THE CHAMBERS

MAY BE USED FOR RETENTION, RECHARGING, DETENTION, CONTROLLING THE FLOW OF ON-SITE STORMWATER RUNOFF.

CHAMBER PROPERTIES

1. THE CHAMBERS WILL BE MANUFACTURED BY CULTEC, INC. OF BROOKFIELD, CT (203-775-4416).

2. CONTACT CULTEC, INC. AT 203-775-4416 FOR SUBMITTAL PACKAGES AND TO PURCHASE PRODUCT.

3. THE NOMINAL CHAMBER DIMENSIONS OF THE CULTEC RECHARGER 330XL SHALL BE 30.5 INCHES TALL, 52 INCHES WIDE

AND 8.5 FEET LONG. THE INSTALLED LENGTH OF INTERMEDIATE UNITS SHALL BE 7 FEET.

4. MAXIMUM INLET OPENING IS 24 INCHES.

5. THE HEAVY DUTY CHAMBER WILL HAVE 16 CORRUGATIONS.

6. THE NOMINAL STORAGE VOLUME OF THE RECHARGER 330XL WILL BE 7.459 CF/LF.

7. THE CHAMBERS WILL BE VACUUM THERMOFORMED OF HIGH MOLECULAR WEIGHT HIGH DENSITY POLYETHYLENE

(HMWHDPE) IN AN ISO-9001:2000 CERTIFIED FACILITY.

8. THE CHAMBER EXTERIOR IS GREY WITH A COLORED STRIPE. THE CHAMBER INTERIOR IS BLACK.

9. CHAMBERS ARE MANUFACTURED WITH AN OPEN BOTTOM, INTEGRALLY FORMED END WALLS AND PERFORATED

SIDEWALLS.

10. THE CHAMBERS WILL BE JOINED USING AN INTERLOCKING OVERLAPPING RIB METHOD. CONNECTIONS MUST BE FULLY

SHOULDERED OVERLAPPING RIBS, HAVING NO SEPARATE COUPLINGS OR SEPARATE END WALLS.

11. THE CHAMBER'S END WALL WILL BE AN INTEGRAL PART OF THE CONTINUOUSLY FORMED UNIT. SEPARATE INLET OR END

PLATES CANNOT BE USED WITH THIS UNIT.

12. THE RECHARGER 330XLR STAND ALONE UNIT MUST BE FORMED AS A WHOLE CHAMBER HAVING TWO FULLY FORMED

INTEGRAL END WALLS.

13. THE RECHARGER 330XLS STARTER CHAMBER MUST BE FORMED AS A WHOLE CHAMBER HAVING ONE FULLY FORMED INTEGRAL END WALL AND ONE PARTIALLY FORMED INTEGRAL ENDWALL WITH A LOWER TRANSER OPENING OF 40.5 INCHES

X 10.5 INCHES.

14. THE RECHARGER 330XLI INTERMEDIATE CHAMBER MUST BE FORMED AS A WHOLE CHAMBER HAVING AT LEAST ONE FULLY FORMED INTEGRAL END WALL AND ONE PARTIALLY FORMED INTEGRAL ENDWALL WITH A LOWER TRANSER

OPENING OF 40.5 INCHES X 10.5 INCHES.

15. THE RECHARGER 330XLE END CHAMBER MUST BE FORMED AS A WHOLE CHAMBER HAVING ONE FULLY FORMED

INTEGRAL END WALL.

16. ALL CHAMBERS WILL BE ARCHED IN SHAPE. THE HEAVY DUTY CHAMBER WILL HAVE FIFTY-SIX ¾ INCH ROUND DISCHARGE HOLES BORED INTO THE SIDEWALLS OF THE UNIT'S CORE TO PROMOTE INFILTRATION/EXFILTRATION.

17. CHAMBERS MUST HAVE HORIZONTAL STIFFENING FLEX REDUCTION STEPS BETWEEN THE RIBS.

18. RECHARGER 330XLHD HEAVY DUTY CHAMBERS ARE DESIGNED TO WITHSTAND AASHTO H20 LOAD RATING (32,000 LBS./AXLE) WHEN INSTALLED ACCORDING TO CULTEC'S RECOMMENDED INSTALLATION INSTRUCTIONS.

19. POLYETHYLENE CHAMBERS MUST HAVE THE ABILITY TO ACCEPT AND CARRY PIPE THROUGH ITS INTEGRALLY FORMED

VERTICAL SUPPORT WALL WITHOUT THE USE OF SEPARATE PIPE HANGERS.

20. UNITS WILL HAVE A RAISED INTEGRAL CAP AT THE TOP OF THE ARCH IN THE CENTER OF EACH UNIT TO BE USED AS AN

OPTIONAL INSPECTION PORT OR CLEAN-OUT.

21. THE UNITS MAY BE TRIMMED TO CUSTOM LENGTHS BY CUTTING BACK TO ANY CORRUGATION.

22. REPEATING SUPPORT PANELS AND END WALLS OF THE ELONGATED CHAMBER SHALL BE SPACED EVERY 7 FEET.

23. THE UNIT WILL ALSO HAVE TWO SIDE PORTALS TO ACCEPT CULTEC HVLV F-24 FEED CONNECTORS. NOMINAL

DIMENSIONS OF THE SIDE PORTAL ARE 10.5 INCHES HIGH BY 12 INCHES WIDE.

SMALL RIB LARGE RIB

102.0" [2591 mm] 84.0" [2135 mm]5" DIA [127 mm]

52.0" [1321 mm]

23.0" [585 mm] 30.5" [775 mm]

10.5" [267 mm]

52.0" [1321 mm]

MODEL 330XL RHD STAND ALONE

MODEL 330XL SHD STARTER

LARGE RIBSMALL RIB

LARGE RIBSMALL RIB

MODEL 330XL IHD INTERMEDIATE

MODEL 330XL EHD END

LARGE RIBSMALL RIB

LARGE RIBSMALL RIB

CULTEC RECHARGER 330XL HD CHAMBER STORAGE = 7.459 CF/FT

INSTALLED LENGTH ADJUSTMENT = 1.5'

ALL RECHARGER 330XL HD HEAVY DUTY UNITS ARE MARKED

WITH A COLOR STRIPE FORMED INTO THE PART ALONG

THE LENGTH OF THE CHAMBER.

ABLE TO ACCEPT F24x4

FEED CONNECTOR

MODEL 330 XL IHD INTERMEDIATE

UNITS ARE USED AS MIDDLE

SECTIONS TO EXTEND THE

LENGTH OF A LINE.

MODEL 330 XL EHD END UNITS

ARE USED TO END THE LENGTH

OF A LINE.

MODEL 330 XL SHD STARTER

STARTER UNITS ARE USED

TO BEGIN A LINE.

MODEL 330 XL RHD STARTER

UNITS ARE USED TO BEGIN A

LINE OR USED AS SINGLE

STAND ALONE SECTIONS.

MODEL EHD

MODEL SHD

MODEL IHD

MODEL RHD

SMALL RIB

END DETAIL

LARGE RIB

END DETAIL

MODEL 330 XL SHD

MODEL 330 XL IHD

MODEL 330 XL IHD

MODEL 330 XL EHD

BEGINNING OF RUN

END OF RUN

HIDDEN END

HIDDEN END

12.0" [305 mm]

6.0" [152 mm]

30.5" [775 mm]

6.0" [152 mm]

4 OZ. NON-WOVEN FILTER FABRIC

AROUND STONE

95% COMPACTED FILLPAVEMENTRECHARGER 330 XL HD

HEAVY-DUTY CHAMBER

18.0" [457 mm]

MIN.

58.0" [1473 mm] 52.0" [1321 mm]12.0" [305 mm]

ALL RECHARGER 330 XL HD HEAVY DUTY UNITS ARE MARKED

WITH A COLOR STRIPE FORMED INTO THE PART ALONG THE

LENGTH OF THE CHAMBER.

ALL RECHARGER 330 XL HD CHAMBERS MUST BE INSTALLED IN

ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE AND

FEDERAL REGULATIONS.

GENERAL NOTES

RECHARGER 330 XL HD BY CULTEC, INC. OF BROOKFIELD, CT.

STORAGE PROVIDED = 11.32 CF/FT PER DESIGN UNIT.

REFER TO CULTEC, INC.'S CURRENT RECOMMENDED

INSTALLATION GUIDELINES.

USE RECHARGER 330 XL HD HEAVY DUTY FOR TRAFFIC AND/OR

H20 APPLICATIONS.

F 24 FEED

CONNECTOR

30.5" [775 mm]

6.0" [152 mm] MIN.

6.0" [152 mm] MIN.

12.0" [305 mm] MIN.

12.0" [305 mm]

(TYP.)

1 - 2 INCH DIA. WASHED,

CRUSHED STONE

CULTEC CONTACTOR 330 XL HD

HEAVY DUTY CHAMBER

FINISHED GRADE

4 OZ. NON-WOVEN FILTER FABRIC

AROUND STONE

95%

COMPACTED FILL

18.0" [457 mm]

MIN.

CULTEC NO. 20L POLETHYLENE LINER

TO SPAN THE ENTIRE WIDTH OF THE

SYSTEM BELOW THE F-24 FEED

CONNECTORS AND SIDE PORTALS

SIDE PORTAL TO BE CUT

IN FIELD TO ALLOW F-24

FEED CONNECTOR

4 OZ. NON-WOVEN FILTER

FABRIC AROUND STONE

1-2 INCH WASHED CRUSHED

STONE BENEATH AND

AROUND CHAMBER BED

CULTEC NO. 20L POLYETHYLENE

LINER ABOVE STONE BASE AND

BENEATH RECHARGER 330 XL HD

HEAVY DUTY CHAMBER SIDE

PORTALS

FINISHED GRADE

95% COMPACTED FILL

1-2 INCH WASHED CRUSHED

STONE BENEATH AND

AROUND CHAMBER BED

CULTEC RECHARGER 330XL HD

HEAVY DUTY CHAMBER

F-24 FEED CONNECTOR

INLET

STRUCTURE

MANIFOLD FEED PIPE

PER ENGINEER DESIGN

(MAX. INLET = 24 INCHES)

CULTEC RECHARGER

330 XL HD CHAMBER

HEADER PIPE PER

ENGINEER DESIGN

CULTEC F-24

FEED CONNECTOR

FUSS & O'NEILL

Disciplines to Deliver

Fi le

P at h:

H

:\D W

G \P

\1

6\ A

\C iv il\

P la n\

A

_D

E T_

-H

O S

P

IT

A L

P A

D .d w g, L ay ou t:

C 5-

Fr i, S ep

4,

- 4

:3

P M

U se r:

ab el l

HOSPITAL PAD

CONSTRUCTION DETAILS

NTS

DFD

ATB

EMB

C5-36

CONSULTANTS:

NEW ENGLAND DISASTER

TRAINING CENTER

Camp Hartell NEDTC Hospital Pad Windsor Locks, Connecticut

REVISION/SUBMISSIONNO.

KEY PLAN:

DATE

DATE:

SCALE:

EYP PROJECT NO.

DESIGNED BY:

DRAWN BY:

CHECKED BY:

2008905.02

09.04.2009

CULTEC RECHARGER 330 XL HEAVY DUTY END DETAIL INFORMATION

CULTEC RECHARGER 330 XL HEAVY DUTY TYPICAL INTERLOCK

CULTEC RECHARGER 330 XL HEAVY DUTY PLAN VIEW CULTEC MANIFOLD DETAIL

CULTEC RECHARGER 330 XL HEAVY DUTY TYPICAL CROSS SECTIONGENERAL NOTES

CULTEC RECHARGER 330 XL HEAVY DUTY THREE VIEW

CULTEC TYPICAL INLET CONNECTION

CULTEC

CULTEC, Inc.

P.O. Box 280 878 Federal Road Brookfield, CT 06804

PH: (203) 775-4416

PH: (800) 4-CULTEC

FX: (203) 775-1462

NO. DATE REVISIONS CULTEC RECHARGER 330HD HEAVY DUTY CHAMBER DETAIL SHEET

Subsurface Stormwater Management Systems

CULTEC DETAIL SHEET

NON TRAFFIC APPLICATION

RECHARGER 330 XL HEAVY DUTY

CULTEC, INC.

N.T.S.

TECH

C5-36