APPENDIX B
Applicable Documents and Standards
The following documents are hereby incorporated by reference. The Contractor shall comply with these documents/standards during the performance of the contract requirements.
ANSI/TIA/EIA-606-A Administration Standard for Commercial Telecommunication Standard FGDC-STD-001-1998 - Content Standard for Digital Geospatial Metadata
FGDC-STD-007.3-1998 - Geospatial Positioning Accuracy Standards Part 3: National Standard for Spatial Data Accuracy
FGDC-STD-007.4-2002 - Geospatial Positioning Accuracy Standards Part 4: Standards for Architecture, Engineering, Construction (A/E/C) and Facilities Management
OSHA CFR 29 Part 1910.146 – Permit-Required Confined Spaces
The Contractor shall obtain and comply with any other applicable manuals not identified above that would be required to meet industry standards.
APPENDIX C
Entities, Attributes, and Domain Values for Recording Required Communication Feature Data (BASIC COMM PATH TEMPLATE)
C.1 Feature Attributes for Comm-Path Entities.
C.1.1 GPS_MANHOLE
C.1.1.1 Definition. An enclosed structure (manhole, hand hole). A butterfly layout is used that shows the floor and walls flattened out so that duct openings can be drawn on the walls. This must be represented as one polygon (one row in the table). The point is used to show the center of the manhole/hand hole cover.
C.1.1.2 Geometry type. Site (Point).
C.1.1.3 Attributes.
Column Name
SDSFIE
Common Name
Description Data Type Use Domain
Table
NAME Identifier Name
The standard identifier name (e.g. MH-19).
Char(20) Required
MH_TYPE_D A description for the type of manhole.
Char(16 Required D_MHTYP
MAPSRC_D Map Source Discriminator
DISCRIMINATOR - Used to indicate the source of data for the spatial position of this graphic.
Char(16) Required D_DATSRC
MAPACU Spatial Accuracy in Meters
Describes the spatial accuracy of mapsrc_d. in meters, +/- of where the feature may actually
be. For example, if you are using GPS and it’s only accurate to 1 meter, put a 1 in this field.
Real Required
C1.2 GPS_VAULT
C.1.2.1 Definition. An enclosed structure in a facility, in which the outside plant cables are spliced to the tipping cables
C.1.2.2 Geometry type. Site (Point).
C.1.2.3 Attributes.
Column Name
SDSFIE
Common Name
Description Data Type Use Domain
Table
NAME Identifier Name
The standard identifier name (i.e. V-19).
Char(20) Required
VLT_MAT_D Vault Material Code
Discriminator References D_COSTRM table. Used to describe the material composition of the vault.
Char(16) Required D_COSTRM
MAPSRC_D Map Source Discriminator
DISCRIMINATOR - Used to indicate the source of data for the spatial position of this graphic.
Char(16) Required D_DATSRC
MAPACU Spatial Accuracy in Meters
Describes the spatial accuracy of mapsrc_d. in meters, +/- of where the feature may actually be. For example, if you are using GPS and it’s only accurate to 1 meter, put a 1 in this field.
C.1.3 GPS_GENERAL_CONTAINER
C.1.3.1 Definition. An aboveground, enclosed structure that provides access to buried plant and a place to house splices, terminals.
C.1.3.2 Geometry type. Site (Point).
C.1.3.3 Attributes.
Column Name
SDSFIE
Common Name
Description Data Type Use Domain
Table
NAME Identifier Name
The standard identifier name (i.e. PED-19).
Char(20) Required
Column Name
SDSFIE
Common Name
Description Data Type Use Domain
Table
TYPE_D Type Code A description for the type of General Container.
Char(16) Required D_COPED
MODEL_NO The model number of the General Container.
Char(16) Required
TERMINAL_D Terminal Existence Code
A Boolean indicating the presence of a terminal (Y/N).
Char(16) Recommended D_BOOLEN
BONDED_D Bonded Code A Boolean indicating whether the General Container is bonded.
(Y/N).
Char(16) Recommended D_BOOLEN
MAPSRC_D Map Source Discriminator
DISCRIMINATOR -
Used to indicate the source of data for the spatial position of this graphic.
Char(16) Required D_DATSRC
MAPACU Spatial Accuracy in Meters
Describes the spatial accuracy of mapsrc_d.
in meters, +/- of where the feature may actually be. For example, if you are using GPS and it’s only accurate to 1 meter, put a 1 in this field.
C.1.4 GPS_DBSPLICE
C.1.4.1 Definition. An enclosed capsule that represents a splice case (aerial or buried).
C.1.4.2 Geometry type. Site (Point).
C.1.4.3 Attributes.
Column Name
SDSFIE
Common Name
Description Data Type Use Domain
Table
NAME Identifier Name
The standard identifier name (e.g. DBS01.1- 1200_1-900).
Char(20) Required
CAS_MAT_D Case Material Code
Used to describe the material composition of the splice case.
Char(16) Required for aerial splices and exposed DB splices
D_SPCMAT
CAS_TYP_D Case Type Code
Used to describe the type of splice case.
Char(16) Required for aerial splices and exposed DB splices
D_SPCCAS
MAPSRC_D Map Source Discriminator
DISCRIMINATOR - Used to indicate the source of data for the spatial position of this graphic.
Char(16) Required D_DATSRC
MAPACU Spatial Accuracy in Meters
Describes the spatial accuracy of mapsrc_d. in meters, +/- of where the feature may actually be. For example, if you are using GPS and it’s only accurate to 1 meter, put a 1 in this field.
C.1.5 GPS_PATH_SEGMENT
C.1.5.1 Definition. Link that represents an enclosure path of comm items outside of a building, manhole, General Container, or other enclosed structure. For duct banks, comm-path segment can represent the virtual path, duct bank, duct, and inner ducts. For ducts, comm-path segment can represent the virtual path, duct, and inner ducts. For direct-buried cables at road-crossings, comm-path segment can represent the virtual path, road-crossing duct, and direct-buried cables.
It can also represent the path of aerial cable, cable-bridges, and cable-troughs.
C.1.5.2 Geometry type. Polyline.
C.1.5.3 Attributes.
‘Column Name
SDSFIE
Common Name
Description Data Type Use Domain
Table
PATH_TYP_D Comm-Path Type Code
A discriminator field that describes what type of communications path this segment is representing.
Char(16) Required D_COPTHT
COVERDEPTH The minimum depth of this part of the path from grade, in inches.
This is mainly used for digging permits
Real Recommended
MAPSRC_D Map Source Discriminator
DISCRIMINATOR -
Used to indicate the source of data for the spatial position of this graphic.
Char(16) Required D_DATSRC
MAPACU Spatial Accuracy in Meters
Describes the spatial accuracy of mapsrc_d.
in meters, +/- of where the feature may actually be. For example, if you are using GPS and it’s only accurate to 1 meter, put a 1 in this field.
C.2 Domain Values for Attributes of Comm-Path Feature Entities.
C.2.1 D_BOOLEN: type list.
C.2.1.1 What it does. A table of Boolean data types YES and NO. Use for selecting the existence or non-existence of a value, condition, or feature.
C.2.1.2 Referenced by: GPS_GENERAL_CONTAINER
C.2.1.3 Attributes.
Lookup Value Long Description YES The condition is true or the feature does exist NO The condition is not true or the feature does not exist
C.2.2 D_COPED: communications – General Container type.
C.2.2.1 What it does. This table contains information about various communications pedestal types.
C.2.2.2 Referenced by: GPS_GENERAL_CONTAINER.
C.2.2.3 Attributes.
Lookup Value Long Description BD BD - Buried Distribution Closure, size unknown
BOX
BOX - Rectangular box type enclosure, accessed by removing a cover panel
CAB CAB - Cabinet enclosure, accessed through a hinged door CAD CAD - Controlled Access Distribution Closure PED4 4 inch pedestal PED6 6 inch pedestal PED8 8 inch pedestal PED12 12 inch pedestal OTHER Other TBD To Be Determined UNKNOWN Unknown
C.2.3 D_COPTHT: communications - comm path type.
C.2.3.1 What it does. This table contains information about various communications path types.
C.2.3.2 Referenced by: GPS_PATH_SEGMENT.
C.2.3.3 Attributes.
Lookup Value Long Description AERIAL Above ground path between, poles, towers or buildings
CABLE_BRIDGE Bridge only used for cables CABLE_TROUGH Pathway on top of ground for cables DIRECT_BURIED Below ground path where soil has direct contact with cable DUCT Single communications duct DUCTBANK A container for multiple ducts STUB-OUT Short duct used with manholes and vaults SURFACE Path directly on the surface UNDER_ROAD A duct for cables, usually under a road UNKNOWN Faulty Source Data
C.2.4 D_COSTRM: structure – material.
C.2.4.1 What it does. This table contains information about various structure materials.
C.2.4.2 Referenced by: GPS_MANHOLE, GPS_VAULT.
C.2.4.3 Attributes.
Lookup Value Long Description AL Aluminum CIS Concrete Cast inSitu/Cast in Place COMBINATION Combination of materials FIBERGLASS Fiberglass PLASTIC Plastic PRECAST Pre-Cast Concrete STEEL Steel
MASONRY Made from bricks, clay tiles, or block.
C.2.5 D_DATSRC: source list – data.
C.2.5.1 What it does. Allowable input values for data sources.
C.2.5.2 Referenced by: GPS_DBSPLICE, GPS_MANHOLE, GPS_PATH_SEGMENT, GPS_GENERAL_CONTAINER, GPS_VAULT.
C.2.5.3. Attributes.
Lookup Value Long Description AS_BUILT As-built drawings FLDLOC_SURVEY Field location survey GPS_FLDLOC GPS field located and verified data
C.2.6 D_MHTYP: type list - comm manhole.
C.2.6.1 What it does. The type of manhole.
C.2.6.2 Referenced by: GPS_MANHOLE.
C.2.6.3 Attributes.
Lookup Value Long Description 1T1 1T1 4T1 4T1 5T1 5T1 6T1 6T1 6T2 6T2 8T1 8T1 A A Type CEMH Controlled Environment Manhole HH_Type_A Handhole Type A J3 J3 Manhole J4 J4 Manhole JC9C JC9C (2450mm x 1750mm x 1450mm) L L Manhole R2A R2A Manhole T T Manhole V V Manhole OTHER Other
C.2.7 D_SPCCAS: communications - splice case type
C.2.7.1 What it does. Allowable values for the type of splice case
C.2.7.2 Referenced by: GPS_DBSPLICE
C.2.7.3 Attributes.
Lookup Value Long Description 12.5x28SS 12.5 Inch Stainless Steel 12.5x38SS 12.5 Inch Stainless Steel 12.5x45SS 12.5 Inch Stainless Steel 12.5x65SS 12.5 Inch Stainless Steel 2 TYPE 2 Type 2BB 2 Inch Better Buried 3BB 3 Inch Better Buried 4BB 4 Inch Better Buried 4x25.8RS 4 Inch ReddiSeal 4x25SS 4 Inch Stainless Steel 6BB 6 Inch Better Buried 5BB 5 Inch Better Buried 6BB 5 Inch Better Buried
7BB 7 Inch Better Buried 6.5x28.4RS 6.5 Inch ReddiSeal 6.5x38.5RS 6.5 Inch ReddiSeal 6.5x22SS 6.5 Inch Stainless Steel 6.5x28SS 6.5 Inch Stainless Steel 9BB 9 Inch Better Buried 9.5x28.4RS 9.5 Inch ReddiSeal 9.5x38.5RS 9.5 Inch ReddiSeal 9.5x28SS 9.5 Inch Stainless Steel 9.5x38SS 9.5 Inch Stainless Steel 9.5x45SS 9.5 Inch Stainless Steel 9.5x53SS 9.5 Inch Stainless Steel 2178-LS 3M™ Series 2178-LS FO-Splice case 2179-CS 3M™ Series 2179-CS FO-Splice case COR Corning Fiber optic splice closure FOSC_100_B_H Raychem FOSC-100 B/H HS Heat Shrink KBV K&B Vault LEAD Lead OTHER Other READY_ACCESS Ready Access UC_6_9 Siemens UC 6-9 UCN_7_10 Siemens UCN 7-10
C.2.8 D_SPCMAT: communications - splice case mat
C.2.8.1 What it does. Allowable input values for the material of the communications splice case
C.2.8.2 Referenced by: GPS_DBSPLICE
C.2.8.3 Attributes.
Lookup Value Long Description AL Aluminum EVA Ethylene Vinyl Acetate (Heat Shrinkable Tubing) FIBER Fiberglass
LEAD LEAD
PE PE - Polyethylene PP PP - Polypropylene PVC PVC - Polyvinyl Chloride SS SS - Stainless Steel OTHER Other
REMAINDER OF PAGE INTENTIONALLY LEFT BLANK
EXAMPLE A – COMMUNICATIONS CONTAINER FIELD DRAWING
12LIOF
FO600-315, 1-12
P30-26FF
01, 1-2750+ A, 2751-3000
2 Type 8-1/2X36
6 ft
4-inch ducts 2x3
3 ea.
1-inch innerducts
4 ea.
1-inch innerducts
6 ft f t
QUEST
P2-24 AIP
48LIOF
FO600-355, 1-24+
FO600-320, 1-12+
FO600-315, 1-12
6 ft
4-inch ducts 2x3
Ground Rod
30 in. dia iron mh cover. No ladder
P2
AIP
36LIOF
Cable Rack
36LIOF
FO 600-1,1-24+
FO600-772,1-12
FO
FO
FO 600-1
4-Inch Stub Out
12LIOF
FO600-320, 1-12
P3-26FF
A,251-300
P30-26FF
P O
HP HO
Manhole 4-inch Knockouts for future duct
P P Plugged duct
4-inch plugged hole 4-inch open hole open duct
O
Container Name MH-3 Bonded Yes_X__No______Alarm Yes___No X Size L 12 ft 6 ft D 6ft Grd.Rod Yes X No___Lid RND X___RET_____ Drainage Type None Duct Plugs Yes___No X Lid Size 30 Inch X Round Lock Present Yes___No X Ladder Yes___No X Lid Material: ( ) Concrete ( X ) Steel Lid Removal Requires Power Equipment Yes__ No X Container Material: Concrete Disposition ( X ) In Service,( ) Abandoned, ( ) Collapsed, ( ) Temporary,( ) Blocked,( ) Plugged, ( ) To Be Determined (TBD), ( ) Unknown Notes__Manhole buried, difficult to find.
48L10F
FO 600-355, 1-24
FO 600-320, 1-12
FO 600-315, 1-12
P2-24PF
09,1-200
3/8-inch minimum from center of hole to edge of tag (typical)
1/4-inch minimum distance from edge of label to edge of tag (typical) 1/8-inch minimum distance from edge of lettering to edge of hole (typical)
Minimum Dimensions of Clearances For ACPI Custom Polyethylene Tags
Not to Scale
Typical ACPI VCT 200 Series Tag with a Label for a Single Copper Cable
EXAMPLE B
EXAMPLE CABLE IDENTIFICATION TAGS
General:
1. Cable Tags are constructed from Avery Heavy Duty, White, Polyester, adhesive labels attached to ACP International (ACPI) VCT-200 and VCT-201 or to ACPI custom-made tags of polyethylene .055-inch thick tag backing with an integral clear laminate flap.
2. Label lettering is 12pt. Arial in permanent black ink printed with a Laser printer process.
3. Cable tags are secured to cable with two 3/16-inch wide, black, Type 6/6 Nylon Cable Ties. Ties are fastened to cable by running tie around cable and through the two holes at each end of tag.
4. Tags for copper cable have black lettering on a white label placed on an orange backing. Tags for fiber cable have black lettering on a white label placed on a yellow backing.
5. Each cable sheath has a single (individual) tag.
P1-24PF
Tag Lettering Example
Not to Scale
Edge of Avery L7992 Polyester Label
Labels for fiber optic cable are placed on a yellow tag backing, copper cable on orange
Labels for copper cable are placed on an orange tag backing, fiber cable on yellow
Label lettering is black Arial bold font, 12 point or larger
Tag has an integral clear plastic laminate flap.
Not to Scale
Avery L7060 Polyester Label
EXAMPLE B – SPECIFICATIONS AND DETAILS FOR CABLE IDENTIFICATION TAGS
TWISTED PAIR CABLE
TAGS
DESCRIPTION OF TAG NOMENCLATURE
CVC EDITOR
ADD NEW CABLE
SHEATH SELECTION
Goto TAB
DESIGNATION
CVC CABLE TAG
SEE NOTES BELOW FOR DESIGNATION
OF TWISTED PAIR CABLE TYPES
TYPE OF OUTER PROTECTION
FOR CABLE.
NUMBER OF CABLE PAIRS IN CABLE,
FOR 100 PAIR CABLES AND UP, DO
NOT INCLUDE “00’S” WHEN LABELING
CABLES.
FOR 24 PAIR CABLES AND LESS USE
AN “X” FOR 25 PAIR CABLES AND UP
USE A “-“.
CABLE GAUGE
TYPE OF CONDUCTOR PROTECTION
CABLE NUMBER
CABLE COUNT
A “+ ALPHA” TO IDENTIFY DEAD
PAIRS
DEAD PAIR COUNT
TWISTED PAIR
FIBER OPTIC CABLE
TAG
ADD NEW CABLE
SHEATH SELECTION
Goto TAB CABLE
OR
OF FIBER OPTIC CABLE TYPES
“A” IF ARMORED, “F” IF FLAME RETARDANT
NUMBER OF FIBERS IN CABLE SHEATH
SHEATH STRUCTURE/TYPE DESIGNATORS
“C” CENTER SUPPORT
“L” LOOSE TUBE
“T” TIGHT TUBE
“B” BLOWN FIBER
“R” RIBBON
CORE OR CLADDING DIAMETER MICRONS)
8.3 CORE FOR SINGLE MODE*
50 OR 62.5 CORE FOR MULTIMODE**
200 CORE
125 CLADDING
140 CLADDING
FILLED, OTHERWISE BLANK
LOCALLY ASSIGNED CABLE NUMBER
“1242/678” FROM/TO BUILDING NUMBERS
COMPLEMENT COUNT
FIBER OPTIC
FO1242/678,1-12
FO1242/688,1-12
FO1242/702,1-12
FO1242/744,1-12
COAXIAL CABLE
(SERVICE TO ATCALS
EQUIPMENT) TAG
ADD NEW CABLE
SHEATH
SELECTION
CVC Goto TAB
OF COAXIAL CABLE TYPES
COXIAL CABLE
“-AIR”, AIR DIELECTRIC
“-FF” FOAM DIELECTRIC
“-FIGURE 8”, FOAM SELF-SUPPORT/FIGURE 8
“-QUAD” , QUAD FOAM DIELECTRIC
“-SOLID” , SOLID DIELECTRIC
“-TWINAX” , TWINAX DIELECTRIC
DESIGNATOR OF METEROROLOGICAL OR ATC
EQUIPMENT TRANMITTING SIGNAL.
COMMON NAME OF COAXIAL CABLE TYPE
CABLE NUMBER
COAXIAL
AN GPN-20 [RG216,
#4]
FIBER OPTIC/TWISTED
PAIR CABLE TAG
ADD NEW CABLE
SHEATH SELECTION
OF FIBER OPTIC/TWISTED PAIR CABLE TYPES. (ALSO,
REFER TO INDIVIDUAL DESCRIPTIONS FOR FIBER OPTIC
AND TWISTED PAIR CABLES)
SHEATH STRUCTURE/TYPE DESIGNATORS
CORE OR CLADDING DIAMETER (MICRONS)
NUMBER OF TWP IN CABLE SHEATH
TWP GAUGE
FIBER OPTIC CABLE DESIGNATOR
LOCALLY ASSIGNED CABLE NUMBER
COMPLEMENT COUNT
TWP DESIGNATOR AND CABLE NUMBER
FIBER OPTIC
/TWISTED PAIR
CA04
F0, 10/634
NUMBER OF PAIRS IN THE TWP CABLE
FIBER OPTIC/COAXIAL
CABLE TAG
CABLE TAG DESIGNATION
OF FIBER OPTIC/TWISTED PAIR CABLE
TYPES. (ALSO, REFER TO INDIVIDUAL
DESCRIPTIONS FOR FIBER OPTIC AND
COAXIAL CABLES)
NUMBER OF FIBERS IN
CABLE SHEATH
SHEATH STRUCTURE/TYPE
DESIGNATORS
CORE OR CLADDING DIAMETER
(MICRONS)
COAXIAL DESIGNATOR
MIL TYPE OF COAXIAL CABLE
FIBER OPTIC CABLE
DESIGNATOR
LOCALLY ASSIGNED
CABLE NUMBER
NUMBER OF FIBERS IN CABLE
SHEATH COMPLEMENT COUNT
FIBER OPTIC/COAXIAL
RG-177U/FO, 167/765
TWISTED PAIR/COAXIAL
CABLE TAG
ADD NEW CABLE
SHEATH
SELECTION
CVC Goto TAB CABLE
OF TWISTED PAIR/COAXIAL CABLE TYPES
TYPE OF OUTER PROTECTION
FOR CABLE.
NUMBER OF CABLE PAIRS IN
CABLE
CABLE GAUGE
TYPE OF CONDUCTOR
PROTECTION
COAXIAL CABLE DESIGNATOR
FOR COMBINATION CABLE
TWP CABLE NUMBER
TWP CABLE COUNT
EQUIPMENT SERVED BY COAXIAL CABLE
TYPE OF COAXIAL CABLE
TWISTED
PAIR/COAXIAL
CA06/AN GPN-20 [RG-216]
SPECIAL OSP CABLE
TYPES-TAGS
ADD NEW CABLE
SHEATH SELECTION
FROM EXAMPLES IN
STANDARD SYMBOLS
FOR TELEPHONE
OUTSIDE PLANT
DRAWINGS
ENGINEERING DATA,
SKETCH 1, SHEET 1
OF SPECIALTYPES OF CABLE
2-19 +8C16 200 PAIR LEAD SHEATH, 19 GAUGE PLUS 8
CONDUCTOR 16 GAUGE
(2) 124 OHM CCTV…TWO 124 OHM CLOSED CIRCUIT TV
CABLES
PAIRS 1-25 LOADED H-88 LOADING
PAIRS 26-100 NOT LOADED
VIDEO PAIRED CABLE, 50 PAIR #22 GAUGE PLUS 6 PAIRS #16
GAUGE
UNKNOWN OR AIP
2-19 + 8C16
(2) 124 OHM CCTV
VCP
SPECIAL OSP CABLE
FROM EXAMPLES IN
STANDARD SYMBOLS
FOR TELEPHONE
OUTSIDE PLANT
DRAWINGS
ENGINEERING DATA,
SKETCH 1, SHEET 1
(2)-RG-177/U
OF SPECIALTYPES OF CABLE
SINGLE PLASTIC SHEATH, 52PAIR, SCREEN (FOR CARRIER
APPLICATION, PLASTIC INSULATED , FILLED
72 QUAD 19 GAUGE SUBMARINE
(2)-RG-177/U TWO RG-177/U COAXIAL CABLES
COAXIAL
P52-S22PF
Unknown or AIP
SUBM72QD-19
(2)-RG-177/U
ATCALS OSP CABLE
ADD NEW CABLE
SHEATH SELECTION
Goto TAB DESIGNATION
CVC CABLE TAG
DESIGNATION
FROM EXAMPLES IN
38MSS Guide to CSIR Drawing Record Maintenance distributed 28 May 97
OF ATCALS CABLE(METEOROLOGICAL AND ATC
CABLES)
NUMBER OF CONDUCTORS AND WIRE GAUGE
FOLLOWED BY THE EQUIPMENT THE CABLE
SERVES.
12C12 AN/TRN-6 TACAN
| C.1 Feature Attributes for Comm-Path Entities. |
| C.1.1 GPS_MANHOLE |
| C.1.1.2 Geometry type. Site (Point). |
| C1.2 GPS_VAULT |
| C.1.2.1 Definition. An enclosed structure in a facility, in which the outside plant cables are spliced to the tipping cables |
| C.1.2.2 Geometry type. Site (Point). |
| C.1.2.3 Attributes. |
| C.1.3 GPS_GENERAL_CONTAINER |
| C.1.3.1 Definition. An aboveground, enclosed structure that provides access to buried plant and a place to house splices, terminals. |
| C.1.3.2 Geometry type. Site (Point). |
| C.1.3.3 Attributes. |
| C.1.4 GPS_DBSPLICE |
| C.1.4.1 Definition. An enclosed capsule that represents a splice case (aerial or buried). |
| C.1.4.2 Geometry type. Site (Point). |
| C.1.4.3 Attributes. |
| C.1.5 GPS_PATH_SEGMENT |
| C.1.5.2 Geometry type. Polyline. |
| C.2 Domain Values for Attributes of Comm-Path Feature Entities. |
| C.2.1 D_BOOLEN: type list. |
| C.2.1.1 What it does. A table of Boolean data types YES and NO. Use for selecting the existence or non-existence of a value, condition, or feature. |
| C.2.1.2 Referenced by: GPS_GENERAL_CONTAINER |
| C.2.1.3 Attributes. |
| C.2.2 D_coped: communications – General Container type. |
| C.2.2.1 What it does. This table contains information about various communications pedestal types. |
| C.2.2.2 Referenced by: GPS_GENERAL_CONTAINER. |
| C.2.2.3 Attributes. |
| C.2.3 D_coptht: communications - comm path type. |
| C.2.3.1 What it does. This table contains information about various communications path types. |
| C.2.3.2 Referenced by: GPS_PATH_SEGMENT. |
| C.2.3.3 Attributes. |
| C.2.4 D_costrm: structure – material. |
| C.2.4.1 What it does. This table contains information about various structure materials. |
| C.2.4.2 Referenced by: GPS_MANHOLE, GPS_VAULT. |
| C.2.4.3 Attributes. |
| C.2.5 D_datsrc: source list – data. |
| C.2.5.1 What it does. Allowable input values for data sources. |
| C.2.5.3. Attributes. |
| C.2.6 D_mhtyp: type list - comm manhole. |
| C.2.6.1 What it does. The type of manhole. |
| C.2.6.2 Referenced by: GPS_MANHOLE. |
| C.2.6.3 Attributes. |
| C.2.7 d_spccas: communications - splice case type |
| C.2.7.1 What it does. Allowable values for the type of splice case |
| C.2.7.2 Referenced by: GPS_DBSPLICE |
| C.2.7.3 Attributes. |
| C.2.8 d_spcmat: communications - splice case mat |
| C.2.8.1 What it does. Allowable input values for the material of the communications splice case |
| C.2.8.2 Referenced by: GPS_DBSPLICE |
| C.2.8.3 Attributes. |
| Lock Present Yes___No X Ladder Yes___No X Lid Material: ( ) Concrete ( X ) Steel |
| Lid Removal Requires Power Equipment Yes__ No X Container Material: Concrete Disposition ( X ) In Service,( ) Abandoned, ( ) Collapsed, ( ) Temporary,( ) Blocked,( ) Plugged, |
| EXAMPLE B – SPECIFICATIONS AND DETAILS FOR CABLE IDENTIFICATION TAGS |
| EXAMPLE B – SPECIFICATIONS AND DETAILS FOR CABLE IDENTIFICATION TAGS |
| EXAMPLE B – SPECIFICATIONS AND DETAILS FOR CABLE IDENTIFICATION TAGS |
| EXAMPLE B – SPECIFICATIONS AND DETAILS FOR CABLE IDENTIFICATION TAGS |
| EXAMPLE B – SPECIFICATIONS AND DETAILS FOR CABLE IDENTIFICATION TAGS |
| EXAMPLE B – SPECIFICATIONS AND DETAILS FOR CABLE IDENTIFICATION TAGS |
| EXAMPLE B – SPECIFICATIONS AND DETAILS FOR CABLE IDENTIFICATION TAGS |
| EXAMPLE B – SPECIFICATIONS AND DETAILS FOR CABLE IDENTIFICATION TAGS |
File details come from the government source that posted it.