A02_Drawing_files___147078___ARCH.pdf

PDF 1 MB Posted

Attached to
Repair building No. 512, Camp Casey
Solicitation number
W91QVN16R0146
Issued by

About this file

Drawing_Arch

View the file

Other files

File Type Posted
W91QVN16R0146_Final.docx DOCX document
A02_Drawing_files___147078___ELEC.pdf PDF
A02_Drawing_files___147078___Title.pdf PDF
A03_Submittal_Register___147078.xls XLS spreadsheet
A02_Drawing_files___147078___CIVIL.pdf PDF
A02_Drawing_files___147078___MECH.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A-1

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

& GENERAL NOTES

EXISTING / REMOVAL FLOOR PLANS

MANUFACTURES INDICATED.

PURPOSES ONLY. AND NOT INTENDED TO LIMIT SELECTIONS TO PRODUCTS OF THE

COLORS AND PATTERNS LISTED BY MANUFACTURES ARE FOR BIDDING IDENTIFICATION 1.

ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER REPRESENTATIVE (COR).

CAUSED BY THIS PROJECT AND SHALL REPAIR THE DAMAGES TO MATCH UP TO

CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES MADE TO EXISTING AREAS

FOR APPROVAL.

CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITION AND SUBMITED TO COR

CONDITION. IN THAT CASE, SHOP DRAWINGS SHALL BE PREPARED AT THE SITE BY THE

SOME DETAILS SHOWN ON CONTRACT DRAWINGS MAY NOT COINCIDE WITH THE FIELD

8.

FOR APPROVAL.

CONTRACTOR SHALL SUBMIT MANUFACTURER'S INSTALLATION SHOP DRAWINGS TO COR

OFFICE, DPW. PER DIRECTION FROM THE INSPECTOR IN CHARGE OR COR

SALVAGE OR SERVICEABLE MATERIALS SHALL BE RETURNED TO SUPPLY OR STORAGE

2.

3.

4.

5.

6.

7.

AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION OR RENOVATION.

THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION

9.

10.

11.

12.

13.

14.

15.

BE AS A PART OF THE CONTRACT DOCUMENT OF THIS PROJECT.

STANDARD DETAIL DRAWINGS FOR O&MA PROJECT, KOREA, DATED OCTOBER 1, 2003 SHALL

NUMBERS ARE FROM TM-5-807-7 AND FEDERAL STANDARD NO. 595b, COLORS.

COLOR OF MATERIALS & PAINTS SHALL BE SELECTED BY USING AGENCY AND COLOR

COMMENCEMENT OF FLOOR TILE WORK.

ALL CONCRETE FLOOR SURFACES SHALL BE LEVELED AND SMOOTHED PRIOR TO

ADDITIONAL COST TO THE GOVERNMENT.

EQUIPMENT, ETC), ELECTRICAL, TELEPHONE AND FIRE ALARM SYSTEM WITHOUT

THE INSTALLATION AND/OR REPLACEMENT OF MECHANICAL (PLUMBING, HEATING,

ITEMS, CUT, PATCH AND RESTORE WALLS, FLOORS AND CEILING WHERE REQUIRED FOR

THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVE/REINSTALL ANY OBSTRUCTED

GENERAL NOTES

MAINTENANCE/OPERATION IAW THE SECTION 3.1.14, OMA STD SPECIFICATION 15181.

PROVIDE ACCESS DOORS FOR CONCEALED VALVES, CONTROLS AND OTHER ITEMS REQUIRING

SCALE: 1/50

EXISTING/REMOVE GROUND FLOOR PLAN

STORAGE AREA

,7

12,800

,8

3,000

,1

,1

,0

1,1008008,3633,000

SLAB, CURB, RAMP & STOOP

: REMOVE EXST CONC FOUNDATIONS,

REPAIR BLDG S-512

CAMP CASEYYI, SC

147078

WALL : 2.29 SM. DEG K/W

ROOF : 3.34 SM. DEG K/W

R-VALUE FOR INSULATION :

CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER

IF THERE ARE ANY CONFLICTS WITHIN THE CONTRACT DOCUMENT, THE GENERAL

OF THE LOAD BEARING WALLS TO PREVENT COLLAPSE OF THE STRUCTURE

APPROPRIATE TEMPORARY SUPPORTS SHOULD BE CONSTRUCTED PRIOR TO DEMOLITION

DETAILS AND GET APPROVAL FROM COR BEFORE FABRICATION AND INSTALLATION.

CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL DOOR/WINDOW

REPAIR / MAINTENANCE (K) WORK

1.

2.

3.

4.

6.

7.

8.

9.

5.

12.

SCOPE OF WORK (ARCHITECTURAL WORK)

10.

11.

REPLACE FIRE EXTINGUISHER BRACKET WITH NEW AS SHOWN ON FLOOR PLAN AND DETAIL DRAWING.

13.

AND DETAIL DRAWING.

REPLACE DETERIORATED EXISTING STEEL GRATING COVER FOR SUMP PIT WITH NEW AS SHOWN ON FLOOR PLAN

14.

A-2

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

SCALE: 1/50

NEW GROUND FLOOR PLAN

D2

STORAGE AREA

FEB

(TYP)

GUARD POST

D1

7503,2003,2003,2003,200750

14,300

,5

,7

7503,2003,2003,2002,2001,000

,5

,7

,2

,7

,9

2,0001,2002,0001,2002,0001,000

1,200

1,2001,200

12,800

REPAIR BLDG S-512

CAMP CASEYYI, SC

147078

& SCOPE OF WORKS

NEW GROUND FLOOR PLANS

REPLACE DETERIORATED EXISTING GUARD POST WITH NEW AS SHOWN ON FLOOR PLAN AND ELEVATIONS.

FLOOR PLAN, ELEVATIONS & LOUVER SCHEDULE.

REPLACE DETERIORATED EXISTING ALUMINUM LOUVERS WITH NEW INCLUDING INSECT SCREEN AS SHOWN ON

L1 L2 L1 L2 L1 L2 L1 L2

L1 L1L1 L1L1 L1

AND ROOF AS SHOWN ON FLOOR PLAN AND SECTIONS.

REPLACE DETERIORATED EXISTING INSULATION INCLUDING VAPOR RETARDER AND PLASTIC VINYL MESH ON WALL

AS SHOWN ON FLOOR PLAN, ELEVATIONS AND DETAIL DRAWINGS.

REPLACE DETERIORATED EXISTING RAIN GUTTERS AND DOWNSPOUTS WITH NEW INCLUDING CONC SPLASH BLOCK

INCLUDING STRUCTURE SUPPORTINGS, GUIDE RAILS, WEATHER STRIPS, MANUAL OPERATOR AND ACCESSORIES.

REPLACE DETERIORATED EXISTING OVERHEAD COILING DOOR WITH NEW GALVANIZED STEEL THERMAL INSULATED

FLOOR PLANS AND SECTIONS.

REPLACE DETERIORATED EXISTING SEALANT CAULKING FOR EXPANSION JOINT ON CONCRETE SLAB AS SHOWN ON

BEEN CORRECTED.

SUCH AS ROUGH OR SCALING CONCRETE, LOW SPOTS, HIGH SPOTS, PAINTING, AND UNEVEN SURFACE SHALL HAVE

FINISH SCHEDULE. THE EXISTING CONCRETE FLOORING SHALL BE SMOOTH, TRUE, LEVEL PLANE WITH ALL DEFECTS

APPLY EPOXY COATING INCLUDING NON SLIP GRIT ON CONCRETE SLAB AS SHOWN ON FLOOR PLANS & INTERIOR

SCHEDULE AND GENERAL SECTIONS.

PAINT ON ALL EXPOSED INTERIOR STEEL STRUCTURE SURFACES AS SHOWN ON FLOOR PLANS, INTERIOR FINISH

FLOOR PLAN AND DOOR SCHEDULE.

REPLACE DETERIORATED EXISTING DOOR AND DOOR FRAME WITH NEW INCLUDING HARDWARE SET AS SHOWN ON

BAIRRER AND NFSM AS SHOWN ON FLOOR PLANS AND DETAIL.

REPLACE DETERIORATED EXISTING CONCRETE SLAB, RAMP AND STOOP WITH NEW INCLUDING WWF, VAPOR

REPLACE EXTERIOR BUILDING IDENTIFICATION SIGNAGES WITH NEW AS SHOWN ON ELEVATIONS AND DETAIL DRAWING.

PLAN, SECTIONS AND DETAIL DRAWINGS.

METAL SIDING INCLUDING ROOF FRAMING, STEEL COULUMNS AND CONCRETE FOUNDATIONS AS SHOWN ON FLOOR

REPLACE DETERIORATED EXISTING ROOF AND EXTERIOR WALLS WITH NEW PROTECTED METAL ROOF AND PROTECTED

ROOF LINE

A-3

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

SCALE:

ELEVATION-1

SCALE:

ELEVATION-3

1/50

1/50

,4

(TYP)

METAL ROOFING

PROTECTED

SCALE:

ELEVATION-2

1/50

SCALE:

ELEVATION-4

1/50

REPAIR BLDG S-512

CAMP CASEYYI, SC

147078

STRAP HANGER

DOWNSPOUT

.4

OR EXP AHR (TYP)

9.53mm DIA. TOGGLE BOLT

NOTES:

1.

2.

PER 305mm.

SLOPE NOT LESS THAN 1.59mm

DOWNSPOUTS AND SHALL HAVE A

HIGH POINTS EQUIDISTANT FROM

GUTTERS SHALL BE HUNG WITH

TYPE

(SQ.MM.)

AREA

RECTANGULAR

PLAIN

(MM)

NOMINAL SIZE

(MM)

ACTUAL SIZE

DIMENSION OF STANDARD DOWNSPOUT

DOWNSPOUT SHAPE

RECTANGULAR

PLAIN

75x7575

& NUT (TYP)

SCREW W/ WASHER

" CAP4

16.35mm DIA. x 3

DOWNSPOUT HANGER DETAIL

GUTTER DESIGN

RECTANGULAR

SCALE: N/A

SCALE: N/A

GUARD POST (TYP)

DOWNSPOUT

RAIN GUTTER &

CONC SPLASH BLOCK

CONC STOOP

CONC RAMP

(TYP)

CONC SPLASH BLOCK

ELEVATIONS AND DETAILSRAIN GUTTER DETAIL DOWNSPOUT DETAIL

SIDE.

HIGHER THAN THE OPPOSITE

SHALL NOT BE LESS THAN 12.70mm

THE REAR SIDE OF THE GUTTER

(TYP)

METAL ROOFING

PROTECTED

DOWNSPOUT

RAIN GUTTER &

(TYP)

METAL WALL SIDING

PROTECTED

(TYP)

METAL WALL SIDING

PROTECTED

S-512

S-512

IDENTIFICATION

BUILDING

GUARD POST (TYP)

CONC RAMP

A-4

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

SCALE: 1/50

3,2003,2003,2003,200

75012,800750

(TYP)

METAL ROOFING

PROTECTED

METAL FLASING

PROTECTED

STORAGE

(TYP)

METAL WALL SIDING

PROTECTED

V A

R

,0

10mmTHK PEJ

S B

SC1

H150x150x7x10

SC1

WORKING POINT

EL=±3400

WORKING POINT

EL=±4800

6756,700675

,1

,3

,0

,0

,0

,0

,0

7,210

,4

,8

WORKING POINT

EL=±3400

7506,7001,500

7,210

,4

,8

5006005,010600500 5006005,010600500

500600

1,1001,0008,1941,9001,100

EXST CONC SLAB

EPOXY COATING ON

NEW CONC SLAB

EPOXY COATING ON

ON CONC RAMP

EPOXY COATING

W/SEALANT (TYP)

S B

(TYP)

METAL ROOFING

PROTECTED

2,500 1,000 2,500

10MM THK PEJ

SCALE: 1/25

CONC RAMP DETAIL

NFSM 900MM THK

CWB 150MM THK

W/BROOM FINISH(TYP)

BARRIER & 150MM CWB

ON GRADE W/ VAPOR

200MM THK. CONC RAMP

(TYP)

HD 13 @300 O.C

(TYP)

HD 13 @300 O.C

SCALE: 1/50

SCALE: 1/50

LONGITUDINAL SECTION

REPAIR BLDG S-512

CAMP CASEYYI, SC

147078

EXST CONC SLAB

EPOXY COATING ON

CROSS SECTION-1 CROSS SECTION-2

A-5

SECTIONS AND DETAIL

(TYP)

W/PLASTIC VINYL MESH

INSULATION & VR

(TYP)

PLASTIC VINYL MESH

INSULATION & VR W/

(TYP)

W/PLASTIC VINYL MESH

INSULATION & VR

(TYP)

PLASTIC VINYL MESH

INSULATION & VR W/

EXST CONC SLAB

SB1

H194x150x6x9

NEW CONC CURB (TYP)

EPOXY COATING ON

A-5

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

SCALE: N/A

SCALE:

GUARD POST

N/A

SCALE:5 N/A

STL GRATING COVER

SC2

H150x150x7x10

10mmTHK PEJ

W/ SEALANT

150THK CONC SLAB

W/ #8-150x150 WWF

3-HD16

4-HD16

2-HD16

HD13 @300 O.C.

600500

1,100

SCALE: 1/20

SB2

SC1

H150x150x7x10

SC1

SCALE:

"SB2" ELEVATION

1/20

T150x150x6.5x9

T150x150x6.5x9

2-L60X60X6

10THK PLATE W/ 2-M20 HSB (TYP.)

9THK

GUSSET PLATE

(TYP.)

T150x150x6.5x9

T150x150x6.5x9

2-L60X60X6

SCALE: 1/10

A-5

SCALE:

1/10

BASE PL W/

200x200x12THK

2-M16 A.B.

(EMBEDDED LG=300)

25THK BEDDING

MORTAR

H150x150x7x10

SCALE: 1/10

10050 50SC1

A-5

(MFR STD)

SUPPORT

STEEL ANGLE

METAL HOODSTRIP

WEATHER

HOUSING (MFR STD)

COILING DOOR

MTL SLATS

INSULATED

GUIDE (PER MFR)

METAL SHUTTER

INTEXT

STRIPPING

WEATHER

METAL SLATS

INSULATED

MFR STD

GUIDE PER

STEEL ANGLE

INT

EXT

1.

2.

OVERHEAD COILING DOOR NOTES

CASING HOOD

GAVANIZED STEEL SLATSTEEL GUIDE RAIL

7A DOOR SECTION 7B HEAD SECTION

7C JAMB

DRAWINGS TO COR FOR APPROVAL.

CONTRACTOR SHALL SUBMIT MANUFACTURER'S INSTALLATION SHOP

(INSIDE OF WALL)

MANUAL CHAIN

OPERATION TYPE INCLUDING WEATHERSTRIPPING.

GALVANIZED STEEL THERMAL INSULATED COILING DOOR WITH MANUAL

OVERHEAD COILING DOOR

@ 30 O.C

32x7x4 BEARING BAR

@ 100 O.C

6x6 CROSS BAR

S B

SC1

H150x150x7x10

FLANGES

BOTH

10THK

STIFFENER

3 SIDES

SB1

H194x150x6x9

W/ 4-M20 HSB

(BOTH SIDE)

6THK COVER PL

6THK PLATE

BENT PLATE

L150x60x6THK

W/ 2-M12 MB

C200x75x25x3.2

P1

W/ 2-M12 MB

L150x90x9

GIRTH

C150x75x25x3.2

L125x75x10x150

W/ 2-M12 MB

W.P.

A

PAINT YELLOW

PAINT BLACK

CONCRETE CAP

GUARD POST

,2

675900

,0

METAL SIDING

PROTECTED

METAL FLASHING

PROTECTED

REPAIR BLDG S-512

CAMP CASEYYI, SC

147078

FLASHING

PROTECTED METAL

FLASHING

PROTECTED METAL

ROOF FRAME DETAIL-1

ROOF FRAME DETAIL-2

COLUMN DETAIL

CLEAN EXST STL ANGLE

DETAILS

CONC FOUNDATION DETAIL

10mmTHK PEJ

W/SEALANT (TYP)

3,200

1,6001,600

A-6

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

NOTES:

1.

INTERIOR FINISH SCHEDULE

FLOOR BASE WALLS CEILING

REMARKS

FINISH COLOR FINISH COLOR FINISH COLOR FINISH COLOR HEIGHT

PAINT VAR

MATERIAL & COLOR SCHEDULE

MAT'L

EXST

MAT'L

NEW

MAT'L

EXST

MAT'L

NEW

MAT'L

EXST

MAT'L

NEW

MAT'L

NEW

MAT'L

EXST

PAINT PT-1

1.

2.

MANUFACTURERS STANDARD MUST APPROACH.

TO INDICATE THE COLOR WHICH THE

IS NOT REQUIRED. THE SELECTIONS SERVE ONLY

AN EXACT MATCH OF THE MANUFACTURERS COLOR

INTENDED TO LIMIT SELECTIONS OF PRODUCTS.

IDENTIFICATION PURPOSES ONLY AND ARE NOT

MANUFACTURERS' COLORS LISTED ARE FOR

3.

FLOOR MATERIAL/COLOR WALL MATERIAL/COLOR CEILING MATERIAL/COLOR

PT-1

FINISH SCHEDULE NOTES

ROOM NAMESROOM NOS

CONC EXP*101 EPOXY EP-1 EXP* --

COLORS SHALL BE APPROVED BY USING AGENCY.

SELECTION OF INTERIOR PAINT AND FACTORY APPLIED

OR APPROVED EQUAL

NOOROO #NR7066 SEMI-GLOSS

PT-1. PAINT ENAMEL

OR APPROVED EQUAL

NOOROO #NR7066 SEMI-GLOSS

PT-1. PAINT ENAMEL

APPROVED BY THE COR OR USING AGENCY.

THE RLFC AREA. EXTERIOR COLOR SCHEME AS

APPLIED COLORS SHALL BE IN ACCORDANCE WITH

SELECTION OF EXTERIOR PAINT AND FACTORY

REMARKS

DOOR DIMENSION

WIDTH

MATERIAL

D1

DOOR

TYPE

DOOR

NOS.

ROUGH OPENING

WIDTH HEIGHT

HDW

SET

THICKHEIGHT NO (HR)

RATED

FIRE

LOUVERGLAZING

CUT

UNDER

FRAME

D2

DOOR

DOOR / WINDOW / LOUVER SCHEDULE

A -21501020 2250 920 44.5 1 - -

B - -- - -3200 3000

METAL METAL

METALMETAL

A

W/ METAL FRAME

B

HDW-1

HINGES A2111, 114x114 (NRP)

WEATHER STRIP & SEAL

1 THRESHOLD J32100

1 DOOR CLOSER C02021

KICK PLATE J102, SST1

1 DOOR STOP & HOLDER

1 LOCKSET 1000-1, F07

(2 EA)

P L A N

DOOR S E C T I O N

STEEL TUBE

CONC STOOP

WELDED TO

STEEL PLATE

50 x 50 x 6THK

FOUNDATION

STEEL PLATE

STEEL TUBE

CONCRETE

170 x 170 x 6THK

WELDED TO

EYEBOLT

HOOK &

DOOR

HOOK & EYEBOLT

STEEL TUBE

CONC)

GALV STEEL

80x80x3.2 THK

50 x 50 x 6 THK STEEL

80x80x3.2 THK

WALL TYPE BUMPER L02101

GALV STEEL TUBE

(FILLED W/CONC)

PLATE WELDED TO

WALL TYPE BUMPER L02101

YELLOW STRIPS

BLACK BACKGROUND

TUBE (FILLED W/

250X250

3.

APPROVAL

AND WINDOW SCHEDULE AND DETAIL DRAWING TO COR FOR

CONTRACTOR SHOULD SUBMIT SHOP DRAWING FOR ALL DOOR

CONNECTED TO STRUCTURE WITH ANCHOR BOLT AND WELDING.

ALL EXTERIOR DOOR FRAME AND WINDOW FRAME SHOULD BE

AND UFC 4-010-01, PAG B-9 & 10, PARA B-3.1 THRU B-3.1.4

ALL EXTERIOR DOOR, GLAZED WINDOW: SEE SEPC SECTION 08391;

1.

2.

FABRICATION AND INSTALLATION

SHALL BE APPROVED BY THE CONTRACTING OFFICER BEFORE

DOORS AND ALUMINUM WINDOWS AS ACTUAL SIZE, AND DRAWINGS

THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL

DOOR & WINDOW NOTES

TO COR.

INSTALL HIGH QUALITY AND GRADE PRODUCTS WITH APPROVAL

COLOR, & QUALITY ARE NOT REQUIRED. BUT CONTRACTOR SHOULD

AN EXACT MATCH OF THE MANUFACTURERS FUNCTION, GRADE,

AND ARE NOT INTENDED TO LIMIT SELECTIONS OF PRODUCTS.

MANUFACTURERS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY

SURFACE

ROOFING

FLASHING

FASCIA

SOFFIT

DOOR & FRAME

HANDRAIL

MATERIAL

ROOF LINER

STEEL

STEEL PIPE

COLOR

CHOCOLATE

COLOR NO.

20095

CHOCOLATE

CHOCOLATE

CHOCOLATE

CHOCOLATE

CHOCOLATE

20095

20095

20095

20095

20095

REMARKS

WALL EIFS

WALL CMU

BEAM/COL CONC

STAIR CONC

SAND-STONE

SAND-STONE

SAND-STONE

SAND-STONE

23617

23617

23617

23617

PROTECTED METAL

PROTECTED METAL

PROTECTED METAL

EXTERIOR COLOR SCHEDULE-1

FS 595B

FS 595B

FS 595B

FS 595B

FS 595B

FS 595B

FS 595B

FS 595B

FS 595B

FS 595B

ELEVATION

SCALE: N/A

BUILDING IDENTIFICATION

SCALE: N/A

DOOR STOP & HOLDER DETAILS

VERIFIED BY COR.

SIZE & LOCATION SHOULD BE

2EA BUILDING IDENTIFICATIONS OF

STORAGE AREA

EP-1

- - - EXP* : EXPOSED STEEL FRAME ONLY

OR APPROVED EQUAL

ABRASIVE GRAIN FINISH

WITH NONSLIP GRIT

TOP: DHDC-6500T

MID: DHDC-6500M

PRIMER: DHDC-6500P

NOROO EPOXY

EPOXY PAINT

METAL DOOR

THERMAL INSULATED

EXT FIELD

IS TO MATCH

LETTER COLOR

WALL COLOR

MATCH

COLOR IS TO

BACKGROUND

ROOF COLOR

7070 760

S-512

8001200ALC - -------ALL1

6501200ALC - -------AL

BUILDING IDENTIFICATION AND DETAIL

W/ BIRD SCREEN

C

& INSECT SCREEN

AL LOUVER OR GRILLE

FFL

DOOR / LOUVER / HARDWARE SCHEDULE

REPAIR BLDG S-512

CAMP CASEYYI, SC

147078

SCHEDULE

LOUVER PER

610X710

2EA

DOOR/LOUVER SCHEDULE & DETAILS

INTERIOR FINISH SCHEDULE,

-/CONC

L2

MANUAL OPERATION

STL FRAME W/

COILING DOOR INCLUDING

INSULATED STL OVERHEAD

10mmTHK PEJ

W/SEALANT (TYP)

147078-Repair Bldg512, Cp Casey-A-1
147078-Repair Bldg512, Cp Casey-A-2
147078-Repair Bldg512, Cp Casey-A-3
147078-Repair Bldg512, Cp Casey-A-4
147078-Repair Bldg512, Cp Casey-A-5
147078-Repair Bldg512, Cp Casey-A-6

File details come from the government source that posted it. Updated .