Attachment_B-_TurboWash_Check_List.pdf

PDF 184 KB Posted

Attached to
Kitchen Equiptment and Installation - Mujuk
Solicitation number
W91QVN-16-R-0049
Issued by

About this file

W91QVN-16-R-0049 Attachment B - Turbo Wash Check List

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

over

TurboWash Check list

Customer Name‐ ____________________ Location‐_____________________ Salesperson‐_________________

Overall length of unit ‐ _______ Overall wall space ‐ _______ (Room sketch very helpful)

Voltage: 208‐240/60/1 208‐240/60/3 480/60/3

Direction of Operation: L‐R or R‐L

Electric Heat: Yes or No

Weld ‐ Located between Wash and Rinse Sinks: Factory, In‐Field (by others), Joiner Bar (adds 2”)

Scrapper: 20” w/ or w/o drain, 36” w/ or w/o drain, 36” w/ disposer

Disposer Cone: 15” (Min. Soiled drainboard of 36”) or SEF 18” (Min. Soiled drainboard of 42”)

Soiled End Edge type: Rolled Rim (1‐1/2”), End Splash (2‐1/2”), Hemmed (0”), Raw Edge, Connects to Dish machine _________

Soiled End Drainboard: Omit, 12”, 18”, 20”, 24”, 30”, 36”, 42”, 48”, 54”, 60” ( special SEF size ____ )

Disposer Piping‐Requires Hobart Disposer: Scrapper, Cone (15” or 18”) or None

Wash Sink Size: 30”, 32”, 36”, 42”, 48”, 54”, 60”, (SEF 72”)

Sump: Yes or No

Rinse Sink Size: Omit, 15”, 18”, 20”, 24”*, 30”*, 36”* (* requires to two faucets)

Sanitizer Sink Size: Omit, 18.5”, 20”, 24”, 30”, 36”

AutoFill: Yes or No

Drains: without overflows or with overflows

Clean End Drainboard: Omit, 12”, 18”, 20”, 24”, 30”, 36”, 42”, 48”, 54”, 60” (special SEF size ____)

Soiled End Edge type: Rolled Rim (1‐1/2”), End Splash (2‐1/2”), Hemmed (0”), Raw Edge, Connects to Dish machine _________

Separator: Yes or No, (54” or larger sink required)

Mixing Faucets: One, Two (see Rinse sink size), or None (Faucets provided by others – Holes punched)

Pre‐Rinse Spray: Yes, No, or None (provided by others‐Holes punched)

Hobart Disposer: Yes or No

Controls: Standard, Single Point including Disposer (Hobart) or Dual point including Disposer (Hobart)

Timer: Yes or No

Utensil Basket: Yes or No

Sheet Rack: Yes or No

CL-44E

over

Undershelf: Yes or No ((clean end or soiled end)(same size as drain board ‐ 30” min.))

Overshelf: Wall mounted, (SEF ‐ Unit mounted) or (SEF ‐ Unit mounted w/ Pot rack –Single or Double)

Chemical Pump: Yes or No, (Can’t be used if unit has Single or Dual point including Disposer controls)

Special features – L‐shaped, U‐shape, special angles all require a detailed room layout – AutoCad files

File details come from the government source that posted it. Updated .