PLANS.pdf
PDF 9 MB Posted
- Attached to
- Colebrook Dam Electrical Upgrades
- Solicitation number
- W912WJ18B0011
About this file
Plans
View the file
Other files
| File | Type | Posted |
|---|---|---|
| BidAbstract.pdf | ||
| W912WJ18B0011_Amnd_2.pdf | ||
| W912WJ18B0011-0001.pdf | ||
| W912WJ18B0011_12Jun18.pdf | ||
| SPECS.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
C O
N C
O R
D
M A
-2
V
IR
G
IN
IA
R
O A
D
N E
W E
N G
L A
N D D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D R
A W
IN
G C
O D
E
S C
A L E
S H
E E
T
F
C
N -C
L -4
C O
L E
B R
O O
K
C O
N N
E C
T
IC
U T
C O
L E
B R
O O
K R
IV
E R L
A K
E D
A M
N E
W T
R A
N S
F O
R M
E R A
N D E
L E
C T
R
IC
A L U
P G
R A
D E
S
W
W J
B
SHEET ID
®of Engineers
US Army Corps
DESIGN FILESHEET NO.
G-001
INDEX TO DRAWINGS
SHEET TITLE
CON-CL-466_G-001.DGN
COLEBROOK, CONNECTICUT
COLEBROOK RIVER LAKE DAM
NEW TRANSFORMER AND ELECTRICAL UPGRADES
A N
S I
D
G-001
:1
ED-601
CON-CL-466_E-101.DGN
CON-CL-466_E-601.DGN
CON-CL-466_ED-601.DGN ELECTRICAL ONE LINE DEMOLITION
E-101
E-601 ELECTRICAL ONE LINE DIAGRAM INSTALLATION
E-602 ELECTRICAL GROUNDING SYSTEM SCHEMATICCON-CL-466_E-602.DGN
NOT TO SCALE
LOCATION PLAN
NOT TO SCALE
VICINITY MAP
MASSACHUSETTS
CONNECTICUT
MASSACHUSETTS
N E
W Y
O R
K
CONNECTICUT
SPRINGFIELD
COLEBROOK
WINSTED
THOMASTON
WATERBURY
HARTFORD
C O
N N E C T
IC
U T R
W912WJ18B0015
of Engineers
US Army Corps
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
New England District
SANDISFIELD
TO NEW BOSTON
TOLLAND
BERKSHIRE COUNTY
LITCHFIELD COUNTY
COLEBROOK
HAMPDEN COUNTY
HARTLAND COUNTY
HARTLAND
GOODWIN DAM
TO WINSTED
PROJECT
LOCATION
PROJECT
LOCATION
L
IT
C H
F
IE
L D C
O U
N T
Y H
A R
T L
A N
D C
O U
N T
Y
RIVER LAKE
COLEBROOK
COVER SHEET AND INDEX TO DRAWINGS
ELECTRICAL PLAN VIEW DEMOLITION AND INSTALLATION
C O
V E
R S
H E
E T A
N D I
N D
E X T
O D
R A
W
IN
G S
B
H E
A D
B
H E
A D
J
C L
IN
E
D
N G
U Y
E N
JUNE 2018
J U
N E
CHANNEL
APPROACH
WEIR
SPILLWAY
C H
A N
N E L
D
IS
C H
A R
G E
O U
T L E
T C
H A
N N
E L
DOWNSTREAM
EMBANKMENT
DAM
UPSTREAM
CHANNEL
APPROACH
OUTLET STRUCTURE
INLET STRUCTURE
INTAKE TOWER
TRANSFORMER
LOCATION OF
NOT TO SCALE
SITE PLAN
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
C O
N C
O R
D
M A
-2
V
IR
G
IN
IA
R
O A
D
N E
W E
N G
L A
N D D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D R
A W
IN
G C
O D
E
S C
A L E
S H
E E
T
N -C
L -4
C O
L E
B R
O O
K
C O
N N
E C
T
IC
U T
C O
L E
B R
O O
K R
IV
E R L
A K
E D
A M
N E
W T
R A
N S
F O
R M
E R A
N D E
L E
C T
R
IC
A L U
P G
R A
D E
S
W
W J
B
SHEET ID
®of Engineers
US Army Corps
B R
IA
N H
E A
D
B R
IA
N H
E A
D
A N
S I
D
ED-601
E L E
C T
R
IC
A L
O N
E L
IN
E
D E
M O
L
IT
IO
N
175A MCB 18 KAIC NORMAL
LOCATION: ENTRY DOOR
CKT# AMPS POLES DESCRIPTION
1 20 1
20 3
20 3
70 3 SPARE
CKT# AMPS POLES DESCRIPTION
FED FROM UTILITY
PANEL N1
GE SPECTRA SERIES
120/208V 3-PHASE 4-WIRE
REMARKS:SERVICE ENTRANCE PANEL
SWITCHGEAR: C.O.E. PAD MOUNTED TRANSFORMER
SUMP PUMP CONTROL PANEL
ELEVATOR LIGHTS
SECURITY & DOOR ALARM
SUMP PUMP
SUMP PUMP
20 1
20 1
70 3
70 3
32014
POWER RECEPTACLE
INSIDE MONORAIL
ELEVATOR MOTOR
OPERATING RM LIGHTS
EQUIPMENT ROOM LIGHTS
TOWER OUTSIDE LIGHTS
175A MCB 18 KAIC NORMAL
LOCATION: ENTRY DOOR
CKT# AMPS POLES DESCRIPTION
1 20 1
15 3
3 PUMP 2
CKT# AMPS POLES DESCRIPTION
PANEL N2
GE SPECTRA SERIES
120/208V 3-PHASE 4-WIRE
20 1
20 1
INTAKE TOWER LIGHTS
20 1
20 1
20 1
20 1
20 1
HEATING ROOM LIGHTS
RECEPTACLE DOWNSTAIRS
PUMP 1125
FUEL PUMP
FURNACE
GATE RM GFCI RCPT & EM LIGHT
SELSYN EMERGENCY
SELSYN SERVO
OUTSIDE RECEPTACLE
EXHAUST FAN
NO LABEL
BRIDGE LIGHTS
RECEPTACLES
CHAMBER LIGHTS
CHAMBER LIGHTS
CHAMBER LIGHTS
REMARKS:BUSS TAPPED OFF ADJACENT PANEL
FED FROM: MAIN BREAKER FED FROM GENERATOR SWITCHGEAR: GENERATOR
KEYED NOTES:
D5
PANEL SCHEDULES DEMOLITION
SCALE: NOT TO SCALE
D1
ELECTRICAL ONE LINE DEMOLITION
A1
EXISTING PAD MOUNTED TRANSFORMER
:1
D
N G
U Y
E N
J .C
L
IN
E
PNL
PNL-N1
12 KVA PNL
PNL-N2
16 KVA
UTILITY
SERV TRANSFORMER
45 KVA
4.8 - 0.208 KV
GENERATOR
69 KVA
PUMP-1
20 HP
PUMP-2
20 HP
BUSS FRN-R(RK-5)
200A
SQD QBL
250/200
OPEN
1.8 Z
UTILITY BUS
CU, 1500'
1-1/C-8 AWG
GENERATOR
PUMP-2
CU, 50'
1-1/C-4/0 AWG
CU, 250'
1-1/C-4/0 AWG
CU, 10'
1-1/C-4/0 AWG
CU, 40'
1-1/C-1 AWG
PUMP-1
CU, 40'
1-1/C-1 AWG
J U
N E
RETAIN GENERATOR FEEDER FOR CONNECTION TO NEW PANELBOARDS.
PANELBOARD TO BE INSTALLED PER SHEET E-601.
RETAIN BRANCH CIRCUIT CONDUCTORS FOR REUSE IN NEW
EACH SECTION OF PANELBOARD.
DEMOLISH PANEL N AND ASSOCIATED CONDUIT AND WIRE BETWEEN
RETAIN CONDUIT FOR REUSE.
AND SERVICE ENTRANCE PANEL IN THE GATE TOWER.
DEMOLISH CONDUCTORS BETWEEN SECONDARY DISCONNECT
DEMOLISH SECONDARY DISCONNECT AND ASSOCIATED FUSES.
FOR USE WITH NEW TRANSFORMER PER SHEETS E-601 AND E-101.
RETAIN PRIMARY CONDUCTORS FOR REUSE. RETAIN CONCRETE PAD
CONDUIT AND CONDUCTORS RUNNING TO SECONDARY DISCONNECT.
DEMOLISH PAD MOUNTED TRANSFORMER AND ASSOCIATED SECONDARY
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
C O
N C
O R
D
M A
-2
V
IR
G
IN
IA
R
O A
D
N E
W E
N G
L A
N D D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D R
A W
IN
G C
O D
E
S C
A L E
S H
E E
T
N -C
L -4
C O
L E
B R
O O
K
C O
N N
E C
T
IC
U T
C O
L E
B R
O O
K R
IV
E R L
A K
E D
A M
N E
W T
R A
N S
F O
R M
E R A
N D E
L E
C T
R
IC
A L U
P G
R A
D E
S
W
W J
B
SHEET ID
®of Engineers
US Army Corps
B R
IA
N H
E A
D
B R
IA
N H
E A
D
A N
S I
D
D2
D1
D7
0 4' 8'2' 0 1' 2'6"SCALE: 1" TO 1'
EL. EQUIPMENT ELEVATION
D1
SCALE: 1/4" TO 1' 0 4' 8'2'D4
SCALE: 1/4" TO 1'
ELECTRICAL PLAN VIEW INSTALLATIONELECTRICAL PLAN VIEW DEMOLITION
SEE SHEET E-601 FOR WIRING DETAIL.
RGS BACK TO PINS 1 AND 2 IN THE GENERATOR CONTROLLER.
SPECIFICATION 26 20 00. PROVIDE (2) #12 AND #12 GND IN 3/4"
ENCLOSURE FOR GENERATOR STARTING CIRCUIT PER
PROVIDE POWER RATED TOGGLE SWITCH IN NEMA-12
SPD TO MINIMIZE WIRE LENGTHS.
COMPLETE THE INSTALLATION. ADJUST THE HEIGHT OF THE
26 20 00. PROVIDE CONDUIT AND WIRE AS REQUIRED TO
PROVIDE SURGE PROTECTIVE DEVICE, SPD, AS SPECIFIED IN
26 20 00.
PROVIDE PANELBOARD PER SHEET E-601 AND AS SPECIFIED IN
JUNCTION BOX TO PANELBOARDS.
PROVIDE (4) #1/0 & #6 GND IN 1.5" RGS FROM THE TAP KIT IN
SQUARE.
00. SIZE JUNCTION BOX PER NFPA 70. BOX SHOWN IS 18"
PROVIDE JUNCTION BOX AND TAP KIT AS SPECIFIED IN 26 20
JUNCTION BOX.
OF THE DOUBLE THROW SAFETY SWITCH TO TAP KIT IN
PROVIDE (4) #1/0 & #6 GND IN 1.5" RGS FROM THE LOAD SIDE
EXTENT POSSIBLE.
REUSE EXISTING CONDUIT AND WIRE TO THE GREATEST
CONTRACTOR'S DISCRETION. MARK AS BUILTS ACCORDINGLY.
FEEDER INTO THE TOP OR SIDE OF THE SWITCH AT
INSTALLED PER THIS SHEET. CONTRACTOR MAY ROUTE
PANELBOARD LOCATION TO DOUBLE THROW SAFETY SWITCH
EXISTING EMERGENCY FEEDER FROM DEMOLISHED
PROVIDE CONDUIT AND WIRE AS REQUIRED TO REROUTE
EXTENT POSSIBLE.
SWITCH. REUSE EXISTING CONDUIT TO THE GREATEST
FEEDER FROM THE PREVIOUS PANEL LOCATION TO THE
TRANSFORMER. PROVIDE CONDUIT AS REQUIRED TO MOVE
DOUBLE THROW SAFETY SWITCH BACK TO SERVICE
PROVIDE CONDUCTORS INDICATED ON SHEET E-601 FROM
LOCATED IN THE TRANSFORMER SECONDARY DISCONNECT.
DISCONNECT TO INDICATE THE SYSTEM BONDING JUMPER IS
SPECIFICATION 26 20 00 AND SHEET E-601. LABEL
PROVIDE DOUBLE THROW SAFETY SWITCH PER
(TVSS), ASSOCIATED DISCONNECT, CONDUIT AND WIRE.
DEMOLISH TRANSIENT VOLTAGE SURGE SUPPRESSOR
CONNECTION TO NEW ELECTRICAL EQUIPMENT.
SHEET IN THE SAME LOCATION. RETAIN FEEDERS FOR
PANELBOARDS TO BE INSTALLED PER SHEET E-601 AND THIS
CONDUIT AND WIRE FOR CONNECTION TO NEW
DEMOLISH PANELBOARDS. RETAIN BRANCH CIRCUIT
:1
E L E
C T
R
IC
A L P
L A
N V
IE
W
D E
M O
L
IT
IO
N A
N D I
N S
T A
L L
A T
IO
N
D
N G
U Y
E N
J
C L
IN
E
D2 D1 D1 I1 I7 I8 I7
I9
I5
I6
I6
I7
I9
I7
I8
I2 I3
I1
I4
J U
N E
E-101
DEMOLITION KEYED NOTES: INSTALLATION KEYED NOTES:
I1
I2
I3
I4
I5
I6
I7
I8
I9
E-101
D7
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
C O
N C
O R
D
M A
-2
V
IR
G
IN
IA
R
O A
D
N E
W E
N G
L A
N D D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D R
A W
IN
G C
O D
E
S C
A L E
S H
E E
T
N -C
L -4
C O
L E
B R
O O
K
C O
N N
E C
T
IC
U T
C O
L E
B R
O O
K R
IV
E R L
A K
E D
A M
N E
W T
R A
N S
F O
R M
E R A
N D E
L E
C T
R
IC
A L U
P G
R A
D E
S
W
W J
B
SHEET ID
®of Engineers
US Army Corps
B R
IA
N H
E A
D
B R
IA
N H
E A
D
A N
S I
D
E L E
C T
R
IC
A L
O N
E L
IN
E D
IA
G R
A M
IN
S
T A
L L
A T
IO
N
NORMAL
LOCATION: ENTRY DOOR
CKT# AMPS POLES DESCRIPTION
20 3
20 3
3 SPARE
CKT# AMPS POLES DESCRIPTION
PANEL N1
175A MCB 18 KAIC
20 1
120/208V 3-PHASE 4-WIRE
REMARKS:SERVICE ENTRANCE PANEL
SWITCHGEAR: C.O.E. PAD MOUNTED TRANSFORMER
SUMP PUMP CONTROL PANEL
ELEVATOR LIGHTS
SECURITY & DOOR ALARM
SUMP PUMP
SUMP PUMP
20 1
POWER RECEPTACLE
INSIDE MONORAIL
ELEVATOR MOTOR
OPERATING RM LIGHTS
EQUIPMENT ROOM LIGHTS
TOWER OUTSIDE LIGHTS
PREPARE SPACE
PREPARE SPACE
PREPARE SPACE
PREPARE SPACE
PREPARE SPACE
PREPARE SPACE
PREPARE SPACE
PREPARE SPACE
PREPARE SPACE
SPARE
SPARE
SPARE1
PREPARE SPACE
PREPARE SPACE
PREPARE SPACE
PREPARE SPACE
PREPARE SPACE
PREPARE SPACE
20 1 SPARE
SPARE120
SPARE120
PREPARE SPACE
PREPARE SPACE
PREPARE SPACE
PREPARE SPACE
PREPARE SPACE
PREPARE SPACE
CKT#
AMPS POLES DESCRIPTION CKT# AMPS POLES DESCRIPTION
PANEL N2
NORMAL
LOCATION: ENTRY DOOR
175A MCB 18 KAIC
120/208V 3-PHASE 4-WIRE
REMARKS:BUSS TAPPED OFF ADJACENT PANEL
20 1
PUMP 2
20 1
EXHAUST FAN
NO LABEL
BRIDGE LIGHTS
RECEPTACLES
CHAMBER LIGHTS
CHAMBER LIGHTS
CHAMBER LIGHTS
20 1
120 INTAKE TOWER LIGHTS
20 1
20 1
HEATING ROOM LIGHTS
RECEPTACLE DOWNSTAIRS
FUEL PUMP
FURNACE
GATE RM GFCI RCPT & EM LIGHT
SELSYN EMERGENCY
SELSYN SERVO
OUTSIDE RECEPTACLE
PUMP 1125
C1
ELECTRICAL ONE LINE DIAGRAM INSTALLATION
B5
ELECTRICAL PANEL SCHEDULES INSTALLATION
20 1 SPARE
SPARE120
SPARE120
SURGE PROTECTIVE DEVICE
20 1 SPARE
SPARE120
SPARE120
FED FROM: SERVICE ENTRANCE MTS
FED FROM: SERVICE ENTRANCE MTS SWITCHGEAR: C.O.E. PAD MOUNTED TRANSFORMER
EATON POWERLINE PRL3A
EATON POWERLINE PRL3A
E-601
:1
D
N G
U Y
E N
J
C L
IN
E
PNL-N1 PNL-N2
PUMP-1
20 HP
PUMP-2
20 HP
GENERATOR
69 KVA
UTILITY
SERV TRANSFORMER
45 KVA
4.8 - 0.208 KV
1.6 Z
SQD QBL
250/200
OPEN
COOPER BAY-O-NET
15A
BUSS FRN-R(RK-5)
150A~
COOPER ELSP
50A
BUSS FRN-R(RK-5)
150A 150A
BUSS FRN-R(RK-5)
OPEN
PANEL PANEL
UTILITY BUS
1-1/C-8 AWG
CU, 1500'
1-1/C-4/0 AWG
CU, 50'
GENERATOR
PIN-2
PIN-1
CONTROLLER
DIGITAL
DGC2020
IN 1/2" RGS
12 AWG WIRE & 12 AWG GND
SWITCH
STARTING
GENERATOR
S.E. MTS
1-1/C-1/0 AWG
CU, 10'
FEEDER TAP
1-1/C-1 AWG
CU, 40'
PUMP-1
1-1/C-1/0 AWG
CU, 10'
1-1/C-1/0 AWG
CU, 10'
1-1/C-1 AWG
CU, 40'
PUMP-2
-1 /C -4 /0 A
W G
C U
J U
N E
KEYED NOTES:
AND WIRE BACK TO EXISTING GENERATOR CONTROLLER.
SPECIFICATION 26 20 00. PROVIDE ASSOCIATED CONDUIT
PROVIDE GENERATOR STARTING SWITCH PER
AND AS SPECIFIED IN 26 20 00.
PROVIDE PANELBOARD AS INDICATED ON THE SCHEDULE
A TAP KIT PER SPECIFICATION 26 20 00.
PROVIDE JUNCTION BOX SIZED PER NFPA 70 CONTAINING
INSTALLED PER KEYED NOTE 6.
INSTALLED PER KEYED NOTE 4 AND IN JUNCTION BOX
PROVIDE TERMINATIONS IN MANUAL TRANSFER SWITCH
PROVIDE (4) 1/0 & #6 GROUND IN 1.5" RIGID STEEL CONDUIT.
TRANSFORMER SECONDARY DISCONNECT.
INDICATE THE SYSTEM BONDING JUMPER IS LOCATED IN THE
26 20 00 WITH FUSES AS INDICATED. LABEL DISCONNECT TO
PROVIDE DOUBLE THROW SAFETY SWITCH PER SPECIFICATION
PER KEYED NOTE 4.
KEYED NOTE 2 AND IN MANUAL TRANSFER SWITCH INSTALLED
PROVIDE TERMINATIONS IN DISCONNECT INSTALLED PER
PROVIDE (4) 4/0 & #3 GROUND IN EXISTING CONDUIT.
TRANSFORMER INSTALLED PER KEYED NOTE 1.
PROVIDE CONDUIT AND WIRE BACK TO PAD MOUNTED
WITH A SPARE SET OF FUSES TO BE LEFT WITHIN ENCLOSURE.
AS SPECIFIED IN 26 20 00. PROVIDE FUSES AS INDICATED
PROVIDE FUSIBLE DISCONNECT IN A NEMA-3R ENCLOSURE
PER SHEET E-602.
PROVIDE CONNECTION TO EXISTING GROUNDING ELECTRODE
IMMERSED FUSES ON THE PRIMARY SIDE OF THE TRANSFORMER.
PROVIDE BAY-O-NET EXPULSION FUSES AND CURRENT LIMITING OIL
CABLE ON THE PRIMARY PER MANUFACTURER'S RECOMMENDATIONS.
PROVIDE TERMINATIONS TO EXISTING MEDIUM VOLTAGE
IN ACCORDANCE WITH SPECIFICATION 26 12 19.
PROVIDE PAD MOUNTED TRANSFORMER AS INDICATED AND
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
C O
N C
O R
D
M A
-2
V
IR
G
IN
IA
R
O A
D
N E
W E
N G
L A
N D D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D R
A W
IN
G C
O D
E
S C
A L E
S H
E E
T
N -C
L -4
C O
L E
B R
O O
K
C O
N N
E C
T
IC
U T
C O
L E
B R
O O
K R
IV
E R L
A K
E D
A M
N E
W T
R A
N S
F O
R M
E R A
N D E
L E
C T
R
IC
A L U
P G
R A
D E
S
W
W J
B
SHEET ID
®of Engineers
US Army Corps
B R
IA
N H
E A
D
B R
IA
N H
E A
D
A N
S I
D
E-602
E L E
C T
R
IC
A L
G R
O U
N D
IN
G S
Y S
T E
M
S C
H E
M A
T
IC
N .T .S
A B C
G
N
PHASE AND NEUTRAL 4/0
STEEL COLUMN
#2 MIN.
SECONDARY
TRANSFORMER
PAD MOUNTED
DISCONNECT
SECONDARY
TRANSFORMER
A B C
A B C
GN
(FUSIBLE)
SAFETY SWITCH
DOUBLE THROW
150A FUSE
150A FUSE
150A FUSE
55 KW GENERATOR SET
(EXISTING)
PHASE AND NEUTRAL 3/0
(NOT EXISTING, CONTRACTOR TO PROVIDE)
#6 EQUIPMENT GROUNDING CONDUCTOR
#2 MIN.
GROUNDING ELECTRODE CONDUCTOR
#2 MIN.
SYSTEM BONDING JUMPER
PHASE AND NEUTRAL 1/0
CONDUCTOR
GROUNDING
#6 EQUIPMENT
SEE PANEL SCHEDULE SHEET E-601.
PANEL-N1
SEE PANEL SCHEDULE SHEET E-601.
PANEL-N2
TAP KIT
CONDUCTOR
GROUNDING
#6 EQUIPMENT
CONDUCTOR
GROUNDING
#6 EQUIPMENT
PHASE AND NEUTRAL 1/0
PHASE AND NEUTRAL 1/0
SYSTEM GROUNDING DETAIL
SCALE: N.T.S.
A1
JUNCTION BOX
EXISTING AT TRANSFORMER PAD
GROUNDING ELECTRODE
DERIVED SYSTEM.
GROUNDED AS A SEPARATELY
VERIFY GENERATOR IS NOT
208 32.6 2.9
208 33.7 3.0
32.5 3.2
34.3 3.1
18.9 1.3
4800 18.9 4.2
VOLTAGE
(INCHES)
BOUNDARY
APPROACH
(CAL/cm2_
ENERGY
INCIDENT
34.0 3.1
CONDUIT AND CABLE SCHEDULE
VOLTAGE
CONDUCTORS
OF
NUMBER
(AWG)
SIZE
WIRE
(AWG)
SIZE
GROUND
SIZE -TYPE
CONDUIT
LENGTH
APPROX.
CONDUIT AND CABLE SCHEDULE NOTES
SOURCE LOAD
3.0"-RGS
SERVICE ENTRANCE TRANSFORMER
10'
120/208V 250'
120/208V 1.5"-RGS
120/208V 1/0 1.5"-RGS
1 2 15SHED GROUNDING ELECTRODE SHED SERVICE ENTRANCE DISCONNECT 0 N/A 0.75"-RGS
UTILITY SERVICE ENTRANCE TRANSFORMER 4800 8 N/A
1500'
EXISTING
TRANSFORMER SECONDARY DISCONNECT
TRANSFORMER SECONDARY DISCONNECT SERVICE ENTRANCE MTS
SERVICE ENTRANCE MTS FEEDER TAP
FEEDER TAP
FEEDER TAP
PANEL N1
PANEL N2
120/208V
120/208V
120/208V
120/208V
4/0 3.0"-RGS
4/0
EXISTING
4.0"-RGS
1/0 1.5"-RGS
1/0
10'
10'
PANEL N1
PANEL N2
BRANCH CIRCUITS (NOTE 2)
BRANCH CIRCUITS (NOTE 2)
EXISTING EXISTING EXISTING EXISTING
SEE PLANS
AS RQRD
10'
EXISTING EXISTING EXISTING EXISTING
SEE PLANS
AS RQRD
120/208V EXISTING EXISTING EXISTING EXISTING
SEE PLANS
AS RQRD
GENERATOR SERVICE ENTRANCE MTS
2 12120/208VGENERATOR 70'GENERATOR STARTING SWITCH 12 0.75"-RGS
EQUIPMENT
SERVICE ENTRANCE TRANSFORMER
TRANSFORMER SECONDARY DISCONNECT
SERVICE ENTRANCE MTS
FEEDER TAP
PANEL N1
PANEL N2
GENERATOR
CONDUCTOR
GROUNDING
#3 EQUIPMENT
LABELS.
RISK ASSESSMENT AND SUBMIT RESULTS FOR REVIEW PRIOR TO PLACING
CONTRACTOR SHALL SUBMIT AN RFI OR CONDUCT AN IN DEPENDANT ARC FLASH
AND USED OTHER THAN THOSE SPECIFICALLY IDENTIFIED IN THE SPECS,
DIFFERENT WIRE OR OVERCURRENT PROTECTIVE DEVICES WERE APPROVED
PROVIDE ARC FLASH LABELS ON EACH PIECE OF EQUIPMENT PER THIS TABLE. IF
D
N G
U Y
E N
J
C L
IN
E
J U
N E
NOTE:
GN
A B C
N G
CBA
2. REFEED CIRCUITS SHOWN ON PANEL SCHEDULE, SEE SHEET E-601.
1. LENGTH ON THIS SCHEDULE IS APPROXIMATE, CONTRACTOR SHALL CONFIRM LENGTH IN THE FIELD.
| CON-CL-466_G-001 |
| CON-CL-466_ED-601 |
| CON-CL-466_E-101 |
| CON-CL-466_E-601 |
| CON-CL-466_E-602 |
File details come from the government source that posted it.