FD
FD
FDFD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
c c ccc c c
WP
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
WP
WP
W P
WP
TV
TV
T V
T V
TV
T V
T V
T V
T V
T V
TV
TV
TV
T V c c
J J
TV
J J
J
J J
J
J
J c
S c c c
J
AVFL EQUIPMENT
ROOM
SECURE STORAGE
MECHANICAL
OFFICE
OFFICE
MENS
AVFL COMPUTER
LAB
WOMEN
ELECTRICAL
OFFICE
AIS MAINTENANCE
TMDE/AFREP
OFFICE
AIS STORAGE
AVFL SHOP
JAN.
BREAK ROOM
OFFICE
OXYGEN ROOM
ELECTRO SHOP
TOOL ROOM
COMM. ROOM
LOCKER ROOM
VESTIBULE
VESTIBULE
CORRIDOR
ELECTRO SHOP
OFFICE
MDP
P1 P2
TBB/GBB
MONACO
FACP/TRANSCEIVER
LOCATION OF
ROOF ACCESS
LDP
T1
HWP-1
CHP-1
CHP-2
UH-2
CU-1
V-117
V-120
V-121
V-123
V-106A
V-108
V-104
V-107
V-114
V-101
V-124
V-118
V-115
V-110
V-113
AH-1
UH-1
1 2
P1:36
P1:26
P1:6
P1:22
P1:31
P2:9,11,13
P2:15,17,19
P1:4
P1:4
P1:4
P1:5
P1:5
P1:5
P1:6
P1:6
P1:6
P1:7 P1:7
P1:7 P1:7
P1:8 P1:8 P1:8
P1:9 P1:9
P1:9 P1:9
P1:9
P1:10P1:10
P1:10
P1:10
P1:10
P1:11
P1:11
P1:11
P1:11
P1:12
P1:12
P1:13
P1:13
P1:14 P1:14
P1:14
P1:14
P1:15
P1:15
P1:15P1:15
P1:16 P1:17
P1:18
P1:19
P1:20
LP
P1:21 P1:23 P1:24
P1:21
P1:22
P1:22 P1:22
P1:22
P1:28
P1:43
P1:25
P1:25
P1:26 P1:26 P1:26
P1:26
P1:26
P1:27
P1:27
P1:27
P1:28 P1:28
P1:28 P1:22
P1:29
P1:30 P1:30
P1:30
P1:30
P1:31P1:31
P1:31
P1:31
P1:31
P1:32P1:32
P1:32
P1:32
P1:32 P1:33 P1:33 P1:33
P1:33
P1:34 P1:34
P1:34
P1:34
P1:35
P1:35 P1:35
P1:36
P1:36 P1:36
P1:36
P1:36
P1:25
P2:26
P1:35
P2:4
P2:4
P2:4
P2:4
7 P
:1
,1
,1
P
:3 ,5
,7
P2:6,8,10
P2:27,29,31
V-106B
V-119
P1:25
TYP.
EF-4
EF-3
EF-1
P2:4
WH-1
WH-2
AC-1
V-111
LDP: 26,28,30
P2: 20,22,24
P2: 21,23,25
LDP: 23
LDP: 23
LDP: 23
LDP: 8
LDP: 8
LDP: 8
LDP: 10
LDP: 10
LDP: 10
LDP: 10
LDP: 10
LDP: 10
LDP: 10
LDP: 10
LDP: 12
LDP: 12
LDP: 12
LDP: 12
LDP: 12
LDP: 12
LDP: 12
LDP: 14,16,18
LDP: 20,22,24
LDP: 19
LDP: 21
LDP: 27,29
LDP: 31,33
AHU-1
LDP: 25
MDP: 7, 9, 11
ADVANTOR ACCESS
CONTROL PANEL
P2:1
DH
DH
DH
DH
DH
DH
P2:1
P2:1
P2:1
P2:1
P2:1
P2:2
EXISTING
CHILLER
MDP: 8,10,12
P1:12
P1:28
V-126
HWC-1
P1:2 P1:39
P1:41
P1:25
P1:1,3
LP:11
MDP-13,15,17
LDP: 7
LDP: 12
P2:2
UTILITY
TRANSFORMER
LCP
C E R T I F
IC
AT
E O F A U
T H
O R
IZ
A T
IO
N
S
OU
TH
CAROLIN
A
CONSULTING
ENGINEERS
DWG, INC.
No.C03649
A R C H I T E C T S
1 2 3 4 5 6
D
E
C
B
A
D
E
C
B
A
1122 LADY STREET, SUITE 810 COLUMBIA, SOUTH CAROLINA 29201
PHONE (803) 799-6502 www.cdacolumbia.com FAX (803) 799-2014
2 3 4
5 6
This document is the property of Curt Davis & Associates, Inc., Architects. The unauthorized reproduction, copying or otherwise use of this document is strictly prohibited and any infringement thereupon may be subject to legal action. Copyright 2012 Curt Davis & Associates, Inc., Architects
McENTIRE PROJECT NO.: PSTE112022
/2
/2
:3 :2
P
M C
U s e rs
\d w ill s \D o c u m e n ts
\1 M
E P
C E
N T
R A
L d w ill s .r v t
E1.1
12-107
MAR
02/02/15
POWER AND DATA PLAN
EASTOVER, SOUTH CAROLINA
McENTIRE JOINT NATIONAL GUARD
BASE
REPAIR AVIONICS FACILITY,
BUILDING 216
B-2 SUBMITTAL
SCALE: 1/8" = 1'-0"E1.1
1 POWER AND DATA PLAN
SCALE: 1/8" = 1'-0"
0' 16' 32'
1 MINIMUM 12" CABLE TRAY
KEYED NOTES
GENERAL NOTES
2 PROVIDE 12" LADDER RACK
3 L5-30 TWIST LOCK RECEPTACLES MOUNTED ABOVE LADDER RACK
4 PAINT 3/4" PLYWOOD WITH FIRE RETARDED PAINT AND MOUNT IN COMM ROOM
FOR BACKBOARD
5 (1) FIBER IN 1" CONDUIT TO JUNCTION BOX.
6 PROVIDE POWER, CATV OUTLET AND DATA FOR TV 18" BFC
7 PROVIDE EXPLOSION PROOF RECEPTACLE
8 PV SYSTEM INVERTER. PV SYSTEM IS ALTERNATIVE BID ITEM #1.
COORDINATE EXACT LOCATION WITH OWNER.
PROVIDE (3) 1" CONDUITS FROM ALARM CONTROL PANEL TO ABOVE CORRIDOR CEILING.
11 FOR CONNECTION TO SMART METER. PROVIDE 1" CONDUIT TO COMMUNICATION ROOM.
12 PROVIDE TWO 4" CONDUITS FROM EXISTING DEMARC IN MECHANICAL 105 TO NEW
COMMUNICATION ROOM 125.
13 ATTACH OMNI-DIRECTIONAL ANTENNA TO SIDE OF BUILDING NEAR ROOF LINE.
COORDINATE EXACT LOCATION.
14 PROVIDE NEW RECEPTACLE AND CONDUCTOR USING EXISTING RACEWAY IN CMU WALL TO
REMAIN.
15 PROVIDE NEW RECEPTACLE IN EXISTING DEVICE BOX AND IN-WALL RACEWAY TO REMAIN.
PROVIDE BOX EXTENSION TO FLUSH MOUNTED RECEPTACLE IN NEW WALL FURRING.
EMERGENCY STOP BUTTON IN KNOX-BOX CONNECTED TO SHUNT TRIP MAIN BREAKER.
COORDINATE FINAL LOCATION WITH AHJ.
PROVIDE JUNCTION BOX WITH 3/4" CONDUIT BACK TO HWC-1 MOTOR CONTROLLER FOR
MANUAL OVERRIDE SWITCH OF HWC-1.
REV# DATE
1. CONTRACTOR SHALL PROVIDE ELECTRICAL CONNECTIONS TO TEMPORARY
TRAILER FROM NEAREST OVERHEAD POLE. GOVERNMENT SHALL FURNISH
POLE MOUNTED TRANSFORMERS FOR TRAILER CONNECTION.
18 TEMPORARY GENERATOR DISCONNECT AND CONNECTOR(S).