PN79439_RTA_PLANS_4of4.pdf
PDF 28 MB Posted
- Attached to
- SOF Advanced Skills Training Facility
- Solicitation number
- W912PM-18-R-0004
About this file
Plans - Volume 4 of 4
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C O
V E
R S
H E
E T
ISSUE DATE:
of Engineers
US Army Corps
Wilmington District
F
IL
E N
A M
E
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S U
B M
IT
T E
D B
Y
D A
T E
C H
E C
K E
D B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
®of Engineers
US Army Corps
"x
S
IZ
E
J
M
IT
C H
E L L
J
M
IT
C H
E L L
W
IL
M
IN
G T
O N
N O
R T
H C
A R
O L
IN
A
D
A R
L
IN
G T
O N A
V E
N U
E W
IL
M
IN
G T
O N D
IS
T R
IC
T U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
G-001
T B
D C
O N
T R
A C
T N o
F E
S C
L U
S A
O F
R E
E M
A N
RFP No.: W912PM18R0004
W P
M
R
R F P N o of Engineers
US Army Corps
Savannah District
ADVANCED SKILLS TRAINING FACILITY
PN: 79439
FORT BRAGG, NORTH CAROLINA
VOLUME 4 OF 4
S
A V
A N
N A
H
G E
O R
G
IA
W
E S
T O
G L E
T H
O R
P E A
V E
N U
E S
A V
A N
N A
H D
IS
T R
IC
T U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
V O
L U
M E O
F
F O
R T B
R A
G G
N O
R T
H C
A R
O L
IN
A P
N
A D
V A
N C
E D S
K
IL
L S T
R A
IN
IN
G F
A C
IL
IT
Y
APRIL 2018
CONTRACT No.: TBD
C A
T E
G O
R Y C
O D
E
-1
-0
P N
C S .d g n
A P
R
IL
SHEET ID. TITLE
INDEX OF DRAWINGS - VOLUME 3
SHEET ID. SHEET ID.TITLE TITLE
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDKRW\Documents\FY16PN79439ITF_PROJECT_R15_K6ENDKRW.rvt
3/21/2018 7:00:52 AM
M
AR
C H
W
2P M
-1 8-
R -0
D es ig ne r
Au th or
Ap pr ov er
1-
-0
GI002
IN
D
EX
O
F D
R A W
IN
G
S
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
6 9 D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
, N C
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
N U
E
SA
VA
N
N
AH
, G A
FO
R
T
BR
AG
G
, N O
R T H
C
AR
O
LI
N A
P N
AD
VA
N C
ED
S
KI
LL
S
TR
A I N
IN
G
F
AC
IL
IT
Y
C he ck er
ISSUED FOR CONSTRUCTION
TN141 SIPRNET PLAN - FIRST FLOOR - PART A
TN142 SIPRNET PLAN - FIRST FLOOR - PART B
TN151 SIPRNET PLAN - SECOND FLOOR - PART A
TN152 SIPRNET PLAN - SECOND FLOOR - PART B
TN161 SIPRNET PLAN - THIRD FLOOR - PART A
TN162 SIPRNET PLAN - THIRD FLOOR - PART B
TN501 COMMUNICATIONS DETAILS
TN502 COMMUNICATIONS DETAILS
TN503 COMMUNICATIONS DETAILS
TN602 CATV RISER DIAGRAM
TN603 FIBER DISTRIBUTION ONE-LINE DIAGRAM
TN604 TELECOMMUNICATIONS CONDUIT ONE-LINE DIAGRAM
TA001 AUDIO VISUAL LEGEND AND NOTES
TA111 FIRST FLOOR ENLARGED AV PLAN-AREA A
TA112 FIRST FLOOR ENLARGED AV PLAN-AREA B
TA121 SECOND FLOOR ENLARGED AV PLAN-AREA A
TA122 SECOND FLOOR ENLARGED AV PLAN-AREA B
TA131 THIRD FLOOR ENLARGED AV PLAN-AREA A
TA132 THIRD FLOOR ENLARGED AV PLAN-AREA B
TA211 FIRST FLOOR ENLARGED AV RCP-AREA A
TA212 FIRST FLOOR ENLARGED AV RCP-AREA B
TA221 SECOND FLOOR ENLARGED AV RCP-AREA A
TA222 SECOND FLOOR ENLARGED AV RCP-AREA B
TA231 THIRD FLOOR ENLARGED AV RCP-AREA A
TA232 THIRD FLOOR ENLARGED AV RCP-AREA B
TA311 ENLARGED AV PLANS
TA401 DISPLAY ELEVATIONS
TA402 DISPLAY ELEVATIONS
TA501 PLATE & BACK BOX MOUNTING DETAILS
TA502 FLOOR BOX DETAIL
TA503 MOUNTING DETAILS
TA504 CREDENZA DETAILS
TA541 SIGHT LINE DETAILS
TA561 RACK DETAILS
TA562 RACK DETAILS
TA563 RACK DETAILS
TA564 RACK DETAILS
TA601 101 & 105 SIGNAL FLOW
TA602 120, 121, 122 AV SIGNAL FLOW
TA603 120, 121, 122 CONTROL SIGNAL FLOW
TA604 142 AV SIGNAL FLOW
TA605 142 CONTROL SIGNAL FLOW
TA606 145, 146, 147 SIGNAL FLOW
TA607 148 AV SIGNAL FLOW
TA608 148 CONTROL SIGNAL FLOW
TA609 152 & 155 SIGNAL FLOW
TA610 202, 205, 211 SIGNAL FLOW
TA611 216 & 217 AV SIGNAL FLOW
TA612 216 & 217 CONTROL SIGNAL FLOW
TA613 227 AV SIGNAL FLOW
TA614 227 CONTROL SIGNAL FLOW
TA615 232 & 241 SIGNAL FLOW
TA616 242 & 243 SIGNAL FLOW
TA617 244 AV SIGNAL FLOW
TA618 244 CONTROL SIGNAL FLOW
TA619 245, 246, 247 SIGNAL FLOW
TA620 248, 249, 250 SIGNAL FLOW
TA621 258 AV SIGNAL FLOW
TA622 258 CONTROL SIGNAL FLOW
TA623 302, 304, 305 SIGNAL FLOW
TA624 310, 311, 313 SIGNAL FLOW
TA625 321 AV SIGNAL FLOW
TA626 321 CONTROL SIGNAL FLOW
TA627 322 SIGNAL FLOW
TA628 328 AV SIGNAL FLOW
TA629 328 CONTROL SIGNAL FLOW
TA630 333,342, 344 SIGNAL FLOW
TA631 345, 346, 347 SIGNAL FLOW
TA632 348, 349, 350 SIGNAL FLOW
TA633 351 & 352 SIGNAL FLOW
MI814 MISC CONTROL POINTS SCHEDULES
MI815 MISC CONTROL POINTS SCHEDULES
MI816 MISC CONTROL POINTS SCHEDULES
MI817 MISC CONTROL POINTS
MI819 VALVE SCHEDULES
MP110 HVAC HYDRONIC PIPING COMPOSITE PLAN FIRST FLOOR
MP111 HVAC HYDRONIC PIPING PLAN - FIRST FLOOR - AREA A
MP112 HVAC HYDRONIC PIPING PLAN - FIRST FLOOR - AREA B
MP120 HVAC HYDRONIC PIPING COMPOSITE PLAN SECOND FLOOR
MP121 HVAC HYDRONIC PIPING PLAN - SECOND FLOOR - AREA A
MP122 HVAC HYDRONIC PIPING PLAN - SECOND FLOOR - AREA B
MP130 HVAC HYDRONIC PIPING COMPOSITE PLAN THIRD FLOOR
MP131 HVAC HYDRONIC PIPING PLAN - THIRD FLOOR - AREA A
MP132 HVAC HYDRONIC PIPING PLAN - THIRD FLOOR - AREA B
E-001 LEGEND AND NOTES
EG111 LIGHTNING PROTECTION PLAN - AREA A
EG112 LIGHTNING PROTECTION PLAN - AREA B
EG501 LIGHTNING PROTECTION DETAILS
EG502 LIGHTNING PROTECTION DETAILS
EG503 LIGHTNING PROTECTION DETAILS
EL111 LIGHTING PLAN - FIRST FLOOR - AREA A
EL112 LIGHTING PLAN - FIRST FLOOR - AREA B
EL121 LIGHTING PLAN - SECOND FLOOR - AREA A
EL122 LIGHTING PLAN - SECOND FLOOR - AREA B
EL131 LIGHTING PLAN - THIRD FLOOR - AREA A
EL132 LIGHTING PLAN - THIRD FLOOR - AREA B
EL501 LIGHT FIXTURE SCHEDULE AND DETAILS
EL502 LIGHT FIXTURE DETAILS
EL503 LIGHT FIXTURE DETAILS
EL504 LIGHTING FIXTURE DETAILS
EL601 LIGHTING CONTROL SCHEDULES AND DIAGRAMS
EL602 LIGHTING CONTROL DIAGRAMS
EP111 POWER PLAN - FIRST FLOOR - AREA A
EP112 POWER PLAN - FIRST FLOOR - AREA B
EP121 POWER PLAN - SECOND FLOOR - AREA A
EP122 POWER PLAN - SECOND FLOOR - AREA B
EP131 POWER PLAN - THIRD FLOOR - AREA A
EP132 POWER PLAN - THIRD FLOOR - AREA B
EP501 POWER PLAN - MISC DETAILS
EP601 POWER RISER DIAGRAM
EP602 PANEL SCHEDULES
EP603 PANEL SCHEDULES
EP604 PANEL SCHEDULES
EP605 PANEL SCHEDULES
EP606 PANEL SCHEDULES
EP607 PANEL SCHEDULES
EP608 PANEL SCHEDULES
EP609 PANEL SCHEDULES
EP610 PANEL SCHEDULES
EP611 PANEL SCHEDULES
EP612 PANEL SCHEDULES
EP613 TR ENLARGED PLANS
EP614 TR ENLARGED PLANS
EX111 ESS AND EXIT SIGN PLAN - FIRST FLOOR- AREA A
EX112 ESS AND EXIT SIGN PLAN - FIRST FLOOR- AREA B
EX121 ESS AND EXIT SIGN PLAN - SECOND FLOOR- AREA A
EX122 ESS AND EXIT SIGN PLAN - SECOND FLOOR- AREA B
EX131 ESS AND EXIT SIGN PLAN - THIRD FLOOR- AREA A
EX132 ESS AND EXIT SIGN PLAN -THIRD FLOOR- AREA B
ESS111 FIRST FLOOR SECURITY PLAN - AREA A
ESS112 FIRST FLOOR SECURITY PLAN - AREA B
ESS121 SECOND FLOOR SECURITY PLAN - AREA A
ESS122 SECOND FLOOR SECURITY PLAN - AREA B
ESS131 THIRD FLOOR SECURITY PLAN - AREA A
ESS132 THIRD FLOOR SECURITY PLAN - AREA B
ESS501 SECURITY CONDUIT PENETRATION DETAILS
ESS502 SECURITY CAMERA DETAILS
ESS503 SECURITY DETAILS
ESS504 SECURITY DETAILS
ESS601 ACCESS CONTROL RISER - MAIN
ESS602 ACCESS CONTROL RISER - SECURE SPACE
ESS603 IDS RISER - MAIN
ESS604 IDS RISER - SECURE SPACE
ESS605 VIDEO SURVEILANCE RISER
ESS701 SECURITY ELEVATIONS
T-001 COMMUNICATIONS LEGEND AND GENERAL NOTES
TN111 COMMUNICATIONS PLAN - FIRST FLOOR - PART A
TN112 COMMUNICATIONS PLAN - FIRST FLOOR - PART B
TN121 COMMUNICATIONS PLAN - SECOND FLOOR - PART A
TN122 COMMUNICATIONS PLAN - SECOND FLOOR - PART B
TN131 COMMUNICATIONS PLAN - THIRD FLOOR - PART A
TN132 COMMUNICATIONS PLAN - THIRD FLOOR - PART B
G-002 COVER SHEET
GI002 INDEX OF DRAWINGS
GI004 ABBREVIATIONS & SYMBOLS
P-001 PLUMBING LEGEND
P-501 PLUMBING DETAILS I
P-502 PLUMBING DETAILS II
P-503 PLUMBING DETAILS III
P-601 PLUMBING SCHEDULES
P-901 PLUMBING ISOMETRIC - SANITARY COMPOSITE
P-902 PLUMBING ISOMETRICS - SANITARY
P-903 PLUMBING ISOMETRIC - WATER COMPOSITE
P-904 PLUMBING ISOMETRICS- DOMESTIC WATER
PL110 SANITARY COMPOSITE PLAN FIRST FLOOR
PL111 SANITARY PLAN FIRST FLOOR - AREA A
PL112 SANITARY PLAN FIRST FLOOR AREA B
PL113 DOMESTIC COMPOSITE FIRST FLOOR PLAN
PL114 DOMESTIC WATER PLAN FIRST FLOOR - AREA A
PL115 DOMESTIC WATER PLAN FIRST FLOOR - AREA B
PL120 SANITARY COMPOSITE PLAN SECOND FLOOR
PL121 SANITARY PLAN SECOND FLOOR - AREA A
PL122 SANITARY PLAN SECOND FLOOR - AREA B
PL123 DOMESTIC WATER COMPOSITE PLAN SECOND FLOOR
PL124 DOMESTIC WATER PLAN SECOND FLOOR - AREA A
PL125 DOMESTIC WATER PLAN SECOND FLOOR - AREA B
PL130 SANITARY COMPOSITE PLAN THIRD FLOOR
PL131 SANITARY PLAN THIRD FLOOR - AREA A
PL132 SANITARY PLAN THIRD FLOOR - AREA B
PL133 DOMESTIC WATER COMPOSITE PLAN THIRD FLOOR
PL134 DOMESTIC WATER PLAN THIRD FLOOR - AREA A
PL135 DOMESTIC WATER PLAN THIRD FLOOR - AREA B
PL401 SANITARY ENLARGED PLAN - FIRST FLOOR MECH ROOM
PL402 SANITARY ENLARGED PLANS - FIRST FLOOR TOILETS & LACTATION 110
PL403 SANITARY ENLARGED PLANS - SECOND FLOOR
PL404 SANITARY ENLARGED PLANS - THIRD FLOOR
PL405 DOMESTIC WATER ENLARGED PLAN - FIRST FLOOR MECH ROOM
PL406 DOMESTIC WATER ENLARGED PLANS - FIRST FLOOR TOILETS & LACTATION 110
PL407 DOMESTIC WATER ENLARGED PLANS - SECOND FLOOR
PL408 DOMESTIC WATER ENLARGED PLANS - THIRD FLOOR
M-001 HVAC LEGEND
M-501 HVAC DETAILS I
M-502 HVAC DETAILS II
M-503 HVAC DETAILS III
M-504 HVAC DETAILS IV
M-505 HVAC DETAILS
M-601 HVAC SCHEDULES I
M-602 HVAC SCHEDULES II
M-603 HVAC SCHEDULES III
M-604 HVAC SCHEDULES IV
M-701 LOW TEMPERATURE WATER PIPING SCHEMATIC
M-702 CHILLED WATER PIPING SCHEMATIC
MH110 HVAC COMPOSITE PLAN FIRST FLOOR
MH111 HVAC PLAN - FIRST FLOOR - AREA A
MH112 HVAC PLAN - FIRST FLOOR - AREA B
MH120 HVAC COMPOSITE PLAN SECOND FLOOR
MH121 HVAC PLAN - SECOND FLOOR - AREA A
MH122 HVAC PLAN - SECOND FLOOR - AREA B
MH130 HVAC PLAN - THIRD FLOOR OVERALL
MH131 HVAC PLAN - THIRD FLOOR - AREA A
MH132 HVAC PLAN - THIRD FLOOR - AREA B
MH301 HVAC SECTIONS I
MH302 HVAC SECTIONS II
MH303 HVAC SECTION III
MH401 HVAC ENLARGED MECHANICAL ROOM PLAN & ELEVATIONS - FIRST FLOOR
MH402 HVAC ENLARGED MECHANICAL ROOM PLAN AND ELEVATIONS - SECOND FLOOR
MH403 HVAC ENLARGED MECHANICAL ROOM PLAN AND ELEVATIONS - THIRD FLOOR
MH404 ENLARGED MECHANICAL ROOM CLEARANCE PLANS
MI001 HVAC CONTROLS LEGEND
MI002 HVAC CONTROLS STSTEM - NETWORK SCHEMATIC
MI003 HVAC CONTROLS POINTS - SCHEDULING INSTRUCTIONS
MI801 AHU-1, AHU-2, & AHU-5 CONTROL SCHEMATIC
MI802 AHU-3, AHU-4 & AHU-6 SCHEMATIC AND LADDER DIAGRAM
MI803 ERV-1, 2 & 3 CONTROL SCHEMATIC
MI804 HYDRONIC CONTROL SCHEMATIC
MI805 HX-1 CONTROL SCHEMATIC
MI806 DHWG-1 CONTROL SCHEMATIC & PUMP LADDER DIAGRAMS
MI807 MISC CONTROL SCHEMATICS
MI808 AHU-1 THRU AHU-6 CONTROL SEQUENCE
MI809 ERV-1 THRU 3 CONTROL SEQUENCE
MI810 HYDRONIC SYSTEMS CONTROL SEQUENCES
MI811 MISC CONTROL SEQUENCES
MI812 AHU-1 THRU 6 CONTROL POINTS SCHEDULE
MI813 ERV-1 THRU 3 CONTROL POINTS SCHEDULE
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
DRAWING ABBREVIATIONS GENERAL NOTES
C (cont) ---------------------
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE, CONTINUOUS
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABEL CLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION
AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE
BOARD (INSULATION)
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED, EXPANSION
EXT EXTERIOR, EXTINGUISHER
EXT GR EXTERIOR GRADE
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR
PANEL
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER
CABINET
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED
GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED
PLASTIC
FRTW FIRE RETARDANT TREATED
WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GEJ GUTTER EXPANSION JOINT
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GFRG GLASS-FIBER-
REINFORCED GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GWB GYPSUM WALL BOARD
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H -------------
HB HOSE BIBB
HC HANDICAPPED
HDPE HIGH DENSITY
POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY
PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING
CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
JT JOINT
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LG LIGHT GAUGE
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTD MOUNTED
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE
WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE
PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION
COEFFICIENT
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PREFIN PREFINISHED
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE
FOOT
PSI POUNDS PER SQUARE
INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER
AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK
MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
R (cont) --------------------
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL SHEET METAL
FLASH (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS STAINLESS STEEL
SSMR STANDING SEAM METAL ROOF
ST STAIRS
STC SOUND TRANSMISSION
COEFFICIENT
STD STANDARD
STL STEEL
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
STRUC STRUCTURAL
SUB FL SUBFLOOR
SUSP SUSPENDED
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
TH THICK
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
TYP TYPICAL
U --------------------
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITER
LABORATORIES
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER
SYSTEM
V --------------------
VAV VARIABLE AIR VOLUME/UNIT
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VTR VENT THRU ROOF
W --------------------
W/ WITH
WC WATER CLOSET
WD WOOD
WDW WINDOW
W/O WITHOUT
WWF WELDED WIRE FABRIC
X --------------------
XFMR TRANSFORMER
A ---------------------
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABV ABOVE
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL
SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH
DISABILITIES ACT
ADJ ADJACENT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED
CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AWT ACOUSTICAL WALL
TREATMENT
B ---------------------
B LABEL CLASS B DOOR
BALC BALCONY
BD BOARD
BDRY BOUNDARY
BEJ BRICK EXPANSION JOINT
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE
MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C LABEL CLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER)
BOARD
CD CONSTRUCTION
DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CFCI CONTRACTOR
FURNISHED/CONTRACTOR
INSTALLED
CFE CONTRACTOR FURNISHED
EQUIPMENT
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL
FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
0 GRID/COLUMN
LINE
DESIGNATOR
INTERIOR ELEVATION
SECTION
ROOM
NAME/NUMBER
REVISION
TAG
PLAN, BLOW-UP DETAIL
PLAN NORTH
NORTH ARROW
w/ TRUE NORTH
INDICATION
SPOT ELEVATION
Name Elevation REFERENCE LEVEL
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
A-101
SIM
A-101
Ref
R ef
R ef
Ref
A101
Ref
R ef
Ref
R ef
EXTERIOR ELEVATION
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
A-101
SYMBOLS
INTERIOR ELEVATION SYMBOL
EXTERIOR ELEVATION SYMBOL
SECTION SYMBOL
CALLOUT SYMBOL
ELEVATION SYMBOL
LEVEL SYMBOL
GENERAL SYMBOLS
Room name
Room name
150 SF
ROOM
NAME/NUMBE
R W/ AREA
CENTERLINE
INDICATOR
1/2 1 21
SCALE: 1"=1'-0"
SCALE BAR
1 View Name 1/8" = 1'-0"R101
MATCHLINE INDICATOR
VIEW TITLE BAR
1 / A-101
1 / A-102
REFERENCE SHEETS
1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO THE CONDITIONS
ON THIS SET OF DRAWINGS TO THE EXTENT APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR ABBREVIATIONS MAY APPEAR IN THIS SET OF DRAWINGS TO INDICATE
SPECIFIC CONDITIONS IN LIEU OF SYMBOLS SHOWN ON THIS SHEET.
SHEET LOGICMATERIALS
EARTH
SAND
CONCRETE/ PRECAST
CONCRETE
STONE
BRICK
CMU
PLYWOOD
RIGID INSULATION
FIBERGLASS BATT
INSULATION
GYPSUM BOARD,
PLASTER
EIFS AE201
DISCIPLINE*:
G - GENERAL
C - CIVIL
L - LANDSCAPE
S - STRUCTURAL
A - ARCHITECTURE
DISCIPLINE
DESIGNATOR
SHEET TYPE
DESIGNATOR
SHEET SEQUENCE
NUMBER (FLOOR*
FOR PLAN VIEWS)
SHEET SEQUENCE
NUMBER (KEY PLAN*
FOR PLAN VIEWS)
F- FIRE PROTECTION
P - PLUMBING
M - MECHANICAL
E - ELECTRICAL
T- TELECOMMUNICATIONS
*ADDITIONAL DISCIPLINES MAY BE USED IN
THIS DRAWING SET.
DRAWING NAMING CONVENTION
SHEET ID
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDKRW\Documents\FY16PN79439ITF_PROJECT_R15_K6ENDKRW.rvt
3/21/2018 7:01:04 AM
M
AR
C H
W
2P M
-1 8-
R -0
D es ig ne r
Au th or
Ap pr ov er
1-
-0
GI004
AB
BR
EV
IA
T I O
N S
SY
M
BO
LS
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
6 9 D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
, N C
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
N U
E
SA
VA
N
N
AH
, G A
FO
R
T
BR
AG
G
, N O
R T H
C
AR
O
LI
N A
P N
AD
VA
N C
ED
S
KI
LL
S
TR
A I N
IN
G
F
AC
IL
IT
Y
C he ck er
ISSUED FOR CONSTRUCTION
M
AR
K D
ES
C
R
IP
TI
O
N D
PO
W
ER
VO
IC
E/
DA
TA
TE
LE
PH
ON
E
SW
IT
CH
/S
EN
SO
R
FA
P
UL
L
ST
AT
IO
N
ID
S
DU
RE
SS
S W
IT
CH
ID
S
KE
YP
AD
TV
P
OW
ER
CA
TV
SW
IT
CH
HO
RN
ST
RO
BE
SW
IT
CH
W
AL
L
PH
ON
E
EDGE OF
DOOR FRAME
(OR DOOR
SIDELIGHT
WHERE
APPLICABLE)
ALIGN DEVICE
CENTERLINE WITH DOOR
CENTERLINE
MOUNTING HEIGHT OF EXIT SIGNS
NOT SHOWN ABOVE DOORWAY
SHALL MATCH OTHER EXIT SIGNS
WITHIN ROOM UNLESS OTHERWISE
NOTED
2" ABOVE BACKSPLASH
(COORDINATE WITH
ARCHITECTURAL)
EXIT EXIT
MARKER BOARD/
WHITE BOARD/
CHALK BOARD
MTD OS
WALL
9'6" AFF
(MAX UOI)
6" UOI
6"
U O
N
U O
N
W
AL
L C
O R
N
ER
O R
E D
G E
BACKSPLASH
COUNTER/SINK
4"
4"
4"
CEILING PLANE
FLOOR PLANE
4" TYP
TYPICAL MOUNTING HEIGHTS
LED LIGHTING FIXTURE, CEILING OR PENDENT MOUNTED AS INDICATED
LED LIGHTING FIXTURE WITH INTEGRAL
EMERGENCY BATTERY BALLAST
LED LIGHTING FIXTURE WALL MOUNTED
MOUNTING HEIGHT AS INDICATED
LED LIGHTING FIXTURE WITH INTEGRAL
EMERGENCY BATTERY BALLAST
LED WALL MOUNTED LIGHT FIXTURE
LIGHTING FIXTURE
LIGHTING FIXTURE WITH INTEGRAL
EMERGENCY BATTERY BALLAST OR
EMERGENCY DRIVER (TYPICAL)
LIGHTING FIXTURE
LIGHTING FIXTURE WITH INTEGRAL
EMERGENCY BATTERY BALLAST
LIGHTING FIXTURE
LIGHTING FIXTURE
LIGHTING FIXTURE WITH INTEGRAL
EMERGENCY BATTERY BALLAST
EXIT LIGHT, CEILING MOUNTED, SHADING INDICATES FACES
DIRECTIONAL ARROWS WHERE INDICATED
EXIT LIGHT, WALL MOUNTED, SHADING INDICATES FACES,
DIRECTIONAL ARROWS WHERE INDICATED. MOUNT BOTTOM OF
FIXTURE 6" ABOVE TOP OF DOOR UNLESS OTHERWISE NOTED
WALL SWITCH, LINE VOLTAGE,TOGGLE,WHERE NO SUBSCRIPT PRESENT,
SINGLE POLE 20A SWITCH. WHERE SUBSCRIPT IS PRESENT,
SUBSCRIPT DENOTES THE FOLLOWING:
3 - THREE WAY SWITCH, (LINE VOLTAGE, 20A)
4 - FOUR WAY SWITCH, (LINE VOLTAGE, 20A)
a - SINGLE LOWER CASE LETTER (EXCEPT LETTERS 'd' AND 'm') DENOTES
THE SWITCH THAT CONTROLS THE FIXTURES (LINE VOLTAGE, 20A)
d -WALL SWITCH, DIMMING, DIMMING PADDLE, LOW VOLTAGE
D_ - RELAY OVERRIDE MULTI-SCENE DIMMING SWITCH (LOW VOLTAGE,
SEE EL 600 SERIES PLATES
DK - MULTI SCENE, DIMMING KEY PAD,LV
DC - MULTI-SCENE DIMMING CONTROL , LV
LV_ -LOW VOLTAGE RELAY OVERRIDE SWITCH (LOW VOLTAGE,
SEE EL600 SERIES PLATES)
WP - WEATHERPROOF (GASKETED)
WALL SENSOR SWITCH, LINE VOLTAGE WALL SWITCH OCCUPANCY
SENSOR SET FOR MANUAL ON AND AUTO/MANUAL OFF, DUAL TECHNOLOGY
(PIR/US)
DIGITAL TIME SWITCH WITH MANUAL-ON/TIMED-OFF OPERATION
AND MANUAL-OFF OVERRIDE. TIME-OUT SETTING SHALL BE SET
FOR 30 MINUTES UNLESS OTHERWISE NOTED
SINGLE STATION CONTROL FOR MOTORIZED PROJECTION SCREEN
(UP-OFF-DOWN)
DUAL TECHNOLOGY (ULTRASONIC AND PASSIVE INFRARED) LOW
VOLTAGE SENSOR, WALL MOUNTED
ULTRASONIC LOW VOLTAGE OCCUPANCY SENSOR, CEILING MOUNTED
UNLESS OTHERWISE INDICATED
LIGHTING CONTROL PANEL
SYSTEM GROUND, SIZE IN ACCORDANCE WITH NEC ARTICLE 250
GROUND ROD, TW INDICATES TEST WELL
LIGHTNING PROTECTION CONDUCTORS. SEE EG DRAWINGS
AIR TERMINAL
PANELBOARD - MH IN ACCORDANCE WITH NEC
DRY TYPE TRANSFORMER
SURGE PROTECTIVE DEVICE
20 AMP DUPLEX RECEPTACLE, SUBSCRIPT DENOTES THE
FOLLOWING:
AFCI - DENOTES ARC FAULT CIRCUIT INTERRUPTER
WP - DENOTES WEATHER PROOF HOUSING, UOI
GFCI - DENOTES GROUND FAULT CIRCUIT INTERRUPTER
EWC - DENOTES FOR ELECTRIC WATER COOLER.
COORDINATE MOUNTING WITH EQUIPMENT PROVIDED
TV - DENOTES FOR TELEVISION. COORDINATE MOUNTING
WITH TV OUTLET
P - CEILING PROJECTOR
20 AMP QUAD RECEPTACLE, MH 1'-6", UON OR UOI
20 AMP QUAD FLOOR RECEPTACLE
20 AMP CEILING MOUNTED RECEPTACLE OUTLET
VGA CEILING OUTLET FOR CONNECTING THE USER'S
PROJECTOR
JUNCTION BOX, WALL MTD. MH 1'-6" U.O.N.
MOTOR RATED SWITCH
MOTOR DISCONNECT/SAFETY SWITCH SHALL BE RATED
30/3/NF/1 UNLESS OTHERWISE INDICATED.
'30' DENOTES SWITCH AMPERE RATING;
'3' DENOTES NUMBER OF POLES;
'NF' DENOTES NON-FUSED ('F' DENOTES FUSED);
'1' DENOTES SWITCH ENCLOSURE'S RATING;
FUSE RATING SHALL BE IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS.
MOTOR STARTER, FURNISHED BY OTHER SECTIONS
BOILER EMERGENCY SHUT-OFF
FIRE-RETARDANT PLYWOOD BACKBOARD WITH NO ADDED
UREA FORMALDEHYDE. SEE SPECIFICATIONS 01 33 29
FOR FSC CERTIFICATION REQUIREMENTS.
A AMPERS
AFF ABOVE FINISHED FLOOR
ATS AUTOMATIC TRANSFER SWITCH
C CONDUIT
CATV CABLE TELEVISION
CB CIRCUIT BREAKER
CKT CIRCUIT
COR CONTRACTING OFFICER'S REPRESENTATIVE
CU COPPER
EF EXHAUST FAN
ELU EMERGENCY LIGHT UNIT
EWC ELECTRIC WATER COOLER
FACP FIRE ALARM CONTROL PANEL
GFGI GOVERNMENT FURNISHED, GOVERNMENT INSTALLED
G GROUND
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GFP GROUND FAULT INTERRUPTER
GND GROUND
HACR HEATING AND AIR CONDITIONING REFRIGERATION
HP HORSEPOWER
HZ HERTZ
IDS INTRUSION DETECTION SYSTEM
IMC INTERMEDIATE METAL CONDUIT
KWH KILOWATT HOUR
LED LIGHT EMITTING DIODE
LT LIGHT
LVS LOW VOLTAGE SWITCH
MCB MOLDED CASE BREAKER
MD MOUNTING DISTANCE
MFR MANUFACTURER
MH MOUNTING HEIGHT
MLO MAIN LUGS ONLY
MNS MASS NOTIFICATION SYSTEM
MTD MOUNTED
NEC NATIONAL ELECTRICAL CODE
NF NON FUSED
NO NUMBER
NTS NOT TO SCALE
OS OCCUPANCY SENSOR
PAF PAINTED AFTER FABRICATION
PH PHASE
PIR PASSIVE INFRARED
R/W RACEWAY
SER SERVICE ENTRANCE RATED
SPD SURGE PROTECTIVE DEVICE
TR TRANSFORMER
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR
TYP TYPICAL
UL UNDERWRITERS LABORATORY
UOI UNLESS OTHERWISE INDICATED
UON UNLESS OTHERWISE NOTED
V VOLT
VT VARIABLE AIR VOLUME TERMINAL UNIT
W, WP WEATHERPROOF
1. SEE PLATE G-002 TO G-002A FOR ABBREVIATIONS AND GENERAL LEGEND.
2. MOUNTING HEIGHT, UNLESS OTHERWISE NOTED, IS TO CENTER LINE OF EQUIPMENT.
3. MOUNT OUTLET BOXES SO THAT NONE OCCUR BACK TO BACK IN WALLS.
4. MECHANICAL EQUIPMENT IS SHOWN IN APPROXIMATE LOCATIONS. FOR EXACT
LOCATIONS OF MECHANICAL EQUIPMENT AND PIPING, SEE MECHANICAL DRAWINGS.
PROVIDE DISCONNECT SWITCHES AS REQUIRED BY THE NATIONAL ELECTRICAL CODE
EVEN IF NOT INDICATED ON THE ELECTRICAL DRAWINGS.
5. COORDINATE THE LOCATIONS AND MOUNTING HEIGHTS OF LIGHTING FIXTURES IN
MECHANICAL AND ELECTRICAL ROOMS WITH THE FINAL LOCATIONS OF PIPES, DUCTS
AND OTHER EQUIPMENT FOR BEST ARRANGEMENT. FIXTURES SHALL BE EASILY
ACCESSIBLE FOR RELAMPING.
6. CONDUCTOR AND CONDUIT SIZES ARE BASED ON COPPER CONDUCTORS WITH THWN
INSULATION IN EMT CONDUIT. CIRCUIT BREAKERS, TERMINALS, ETC. SHALL BE RATED
AND MARKED FOR 75 DEGREES MINIMUM. THE CONTRACTOR SHALL ADJUST CONDUIT
SIZES BASED ON ACTUAL TYPE OF CONDUCTORS AND CONDUIT INSTALLED.
7. CIRCUIT NUMBERS ARE SHOWN ADJACENT TO ELECTRICAL DEVICES. WIRING SHALL
BE IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS AND/OR
REQUIREMENTS.
8. ALL WIRING SHALL BE CONCEALED UNLESS EXPLICITLY INDICATED OTHERWISE.
CONDUITS SHALL NOT BE RUN IN ANY UL RATED SLAB.
9. REVISE PANELBOARD SCHEDULES ON AS-BUILT-DRAWING AND PANEL DIRECTORIES
TO REFLECT FINAL INSTALLATION CONDITIONS.
10. SEAL PENETRATIONS THROUGH ROOFS, CEILINGS, FLOORS, WALLS AND FIRE
WALLS TO MAINTAIN THE INTEGRITY OF THE AIR BARRIER, FIRE AND ACOUSTIC
RATINGS OF THE ROOF, CEILINGS, WALLS AND FLOORS.
11. COMPONENTS WHICH CONSTITUTE AN ELECTRICAL SYSTEM SHALL BE FULLY
COMPATIBLE WITH ONE ANOTHER AND SHALL BE APPROVED BY THE VARIOUS
MANUFACTURERS FOR USE WITH ALL OTHER COMPONENTS WITHIN THE SYSTEM. (ONE
EXAMPLE OF AN ELECTRICAL SYSTEM IS THE BUILDING LIGHTING SYSTEM COMPRISED
OF FIXTURES, LAMPS, SWITCHES, BALLASTS, OCCUPANCY SENSORS AND DIMMING
EQUIPMENT).
12. LOCATE ALL RACEWAYS TO AVOID INTERFERENCE WITH DUCTS, PIPES,
MECHANICAL EQUIPMENT, WITH REMOVAL OF CEILING TILES, OR WITH ACCESS TO
EQUIPMENT WHICH REQUIRES PERIODIC ADJUSTMENT OR MAINTENANCE.
13. PROVIDE NAMEPLATES ON THE EXTERIOR OF ALL
ELECTRICAL PANELS AND ENCLOSURES AS FOLLOWS: DEVICE
ID, DEVICE RATING, POWER SOURCE, ARC FAULT DATA.
14. FOR DISCONNECT SWITCHES AND MOTOR STARTERS THE
TOP LINE SHALL BE THE NAME/DESIGNATIONOF THE
EQUIPMENT BEING FED BY THE SWITCH/STARTER.
15. PROVIDE SEPARATE NEUTRALS FOR EACH CIRCUIT
UTILIZING A NEUTRAL CONDUCTOR (DO NOT COMBINE
NEUTRALS).
16. PROVIDE EQUIVALENT CONDUIT PATHWAYS WHERE CABLE
TRAY IS INTERRUPTED BY NONACCESSIBLE CEILINGS.
17. THE INTERRUPTING RATING OF THE PANELBOARDS AND
ELECTRICAL EQUIPMENT SHALL BE INCREASED TO THE NEXT
AVAILABLE RATING WHERE THERE IS NOT A RATING THAT IS
EQUAL TO THE EQUIPMENTS LISTED SHORT CIRCUIT RATING.
18. PROVIDE GROUNDING CONDUCTORS IN ALL CONDUITS.
19. RACEWAYS CROSSING STRUCTURAL EXPANSION JOINTS OR
SEISMIC JOINTS SHALL BE PROVIDED WITH SUITABLE
EXPANSION FITTINGS OR OTHER SUITABLE MEANS TO
COMPENSATE FOR THE BUILDING EXPANSION AND
CONTRACTION AND TO PROVIDE FOR CONTINUITY OF
GROUNDING.
20. RECEPTACLES THAT HAVE GFI PROTECTION ARE TO BE
WIRED SUCH THAT THE LOSS OF POWER ON ONE RECEPTACLE
DOES NOT AFFECT DOWNSTREAM RECEPTACLES.
21. UNLESS OTHERWISE NOTED, EMT CONDUIT SHALL BE
INSTALLED IN EXPOSED DRY AREAS WITH COMPESSION
FITTINGS. CONDUIT SHALL BE INSTALLED IN ACCORDANCE WITH
THE SPECIFICATIONS. EXPOSED OUTLET BOXES SHALL BE CAST
METAL WITH THREADED FITTINGS AND COVERS THAT FIT FLUSH
WITH THE EDGES OF THE OUTLET BOXES. EXPOSED
CONDUITAND OUTLET BOXES SHALL BE PAINTED TO MATCH THE
WALLS OR WIRE MESH.
22. CONTRACTOR SHALL MAINTAIN A MINIMUM OF 6"
SEPARATION BETWEEN POWER OUTLETS PATHWAYS AND
TELECOMMUNICATIONS OUTLETS PATHWAYS.
LOWER CASE DENOTES THE SWITCH THAT CONTROLS FIXTURE
LUMINAIRE TYPE DESIGNATION
SYMBOL DENOTES GENERAL TYPE OF LUMINAIRE
UNSWITCHED NIGHT LIGHT (ON 24 HOURS)
a A2
NT
ELECTRICAL LEGEND
ABBREVIATIONS
GENERAL NOTES
(NOT TO SCALE)
M
OS
T
PS
LCP
OS
OS
TW
TR#
C
J
B
TTB
CTB
V
SPD
SP
IR
NE
T
U O
N
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
FOR OFFICIAL USE ONLY (FOUO)
FOR OFFICIAL USE ONLY (FOUO)
FO
R
O
FF
IC
IA
L U
SE
O
N
LY
(F O
U O
C:\Users\K6ENDRB9\Documents\FY16PN79439ITF_MEP_R15_K6ENDRB9.rvt
3/19/2018 3:14:15 PM
M
AR
C H
W
2P M
-1 8-
R -0
XX
XX
X-
XX
-X -X
XX
X
R . B
R
IT
O
- J.
S
TE
IN
1-
-0
E-001
LE
G
EN
D
A N
D N
O
TE
S
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
6 9 D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
, N C
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
N U
E
SA
VA
N
N
AH
, G A
FO
R
T
BR
AG
G
, N O
R T H
C
AR
O
LI
N A
P N
AD
VA
N C
ED
S
KI
LL
S
TR
A I N
IN
G
F
AC
IL
IT
Y
R . D
AV
IS
ISSUED FOR CONSTRUCTION
M
AR
K D
ES
C
R
IP
TI
O
N D
UP
FD
GFCIGFCI
1 2 3 4 5
E
F
G
H
1. SEE SHEET E-001 FOR ELECTRICAL LEGEND & NOTES AND
SHEETS EG501 FOR LIGHTNING PROTECTION & GROUNDING
DETAILS.
2. ENSURE THAT ALL CONDUCTOR BENDS HAVE AT LEAST
AN 8" RADIUS AND NOT LESS THAN 90 DEGREE BEND ANGLE.
3. NOT USED.
4. ROOF CONDUCTORS SHALL BE CONCEILED. PENETRATIONS
SHALL BE IN ACCORDANCE WITH ROOF MANUFACTURER'S
RECOMMENDATIONS AND WARRANTY.
5. ALL DOWN CONDUCTORS SHALL BE CONCEALED WITHIN WALLS.
EXCEPT ON THE SCIFF ARE. GROUNDING IN THE SCIFF AREA SHALL
BE SURFACES MOUNTED
6. THE LIGHTNING PROTECTION INSTALLERS SHALL COORDINATE
WITH THE ROOF INSTALLERS CONCERNING REQUIREMENTS FOR
DIFFERING METALS.
7. CONNECTIONS TO THE STRUCTURAL STEEL FRAMEWORK SHALL
BE MADE AT AREAS THAT HAVE BEEN CLEANED TO THE BASE
METAL BY USE OF BONDING PLATES (HAVING A SURFACE
CONTACT AREA OF NOT LESS THAN 8 SQ-IN) OR BY WELDING OR
BRAZING. WHERE RUST-PROTECTIVE COATING OF PAINT IS
REMOVED, THE BASE STEEL SHALL BE PROTECTED WITH A
CONDUCTIVE, CORROSION-INHIBITING COATING.
8. PROVIDE PVC SLEEVE WHEREVER GROUNDING CONDUCTOR
MUST PASS THROUGH EXTERIOR WALL, CONCRETE PAD, SLAB,
OR FOUNDATION GRADE BEAM.
9. PROVIDE A COUNTERPOISE CONSISTING OF A #4/0 AWG BARE
COPPER CONDUCTOR A MINIMUM OF 30" BELOW FINISHED
GRADE AND 5'-0" FROM THE BUILDING'S EXTERIOR WALL.
10. GROUND RODS SHALL BE INSTALLED MINIMUM 2'-6" BELOW
GRADE AND MINIMUM 2'-0" FROM FOUNDATION WALL. GROUND
RODS SHALL PENETRATE EARTH AT LEAST 10'-0".
11. INTERCONNECT LIGHTNING PROTECTION SYSTEM TO THE
ELECTRICAL SERVICE GROUND, COMMUNICATIONS GROUND,
AND ALL UNDERGROUND METALLIC PIPING SYSTEMS IN
ACCORDANCE WITH THE NEC, ARTICLE 250.
12, SEE SHEET EG502 FOR ADDITIONAL REQUIRED CONNECTIONS
TO THE COUNTERPOISE.
13. ALL METALLIC ROOF PENETRATIONS WITH METAL EQUAL TO
OR GREATER THAN 0.1875-INCHES THICK SHALL BE BONDED
TO THE LIGHTNING PROTECTION SYSTEM, UNLESS LOCATED
UNDER THE ZONE OF PROTECTION. ALL NON-METALLIC ROOF
PENETRATIONS AND ALL METALLIC ROOF PENETRATIONS WITH
METAL LESS THAN 0.1875-INCHES THICK SHALL BE PROVIDED
WITH AIR TERMINALS CONNECTED TO THE ROOF CONDUCTORS,
UNLESS LOCATED UNDER THE ZONE OF PROTECTION.
COORDINATE WITH OTHER TRADES FOR ROOF PENETRATION
LOCATIONS.
14. BOND ALL ANTENNAS AND SUPPORTS TO THE LIGHTNING
PROTECTION SYSTEM.
GENERAL NOTES:
DOWN CONDUCTOR
(TYPICAL)
COUNTERPOISE
(TYPICAL)
1 2 4 5
F
G
H
GROUND ROD
WITH TEST WELL
TW
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
FOR OFFICIAL USE ONLY (FOUO)
FOR OFFICIAL USE ONLY (FOUO)
FO
R
O
FF
IC
IA
L U
SE
O
N
LY
(F O
U O
C:\Users\K6ENDRB9\Documents\FY16PN79439ITF_MEP_R15_K6ENDRB9.rvt
3/19/2018 3:14:26 PM
M
AR
C H
W
2P M
-1 8-
R -0
XX
XX
X-
XX
-X -X
XX
X
R . B
R
IT
O
- J.
S
TE
IN
1-
-0
EG111
LI
G
H
TN
IN
G
P R
O T E
C
TI
O N
P
LA
N
AR
EA
A
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
6 9 D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
, N C
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
N U
E
SA
VA
N
N
AH
, G A
FO
R
T
BR
AG
G
, N O
R T H
C
AR
O
LI
N A
P N
AD
VA
N C
ED
S
KI
LL
S
TR
A I N
IN
G
F
AC
IL
IT
Y
R . D
AV
IS
ISSUED FOR CONSTRUCTION
Roof_Lightning Protection_WORK -AREA A1
KEY PLAN
A
B
PLAN NORTH
M
AR
K D
ES
C
R
IP
TI
O
N D
1 2 3 4 5
B
D
C
GROUND ROD
WITH TEST WELL
AIR TERMINAL
(TYPICAL)
ROOF CONDUCTOR
(TYPICAL)
DOWN CONDUCTOR
(TYPICAL)
1. SEE SHEET E-001 FOR ELECTRICAL LEGEND & NOTES AND
SHEETS EG501 FOR LIGHTNING PROTECTION & GROUNDING
DETAILS.
2. ENSURE THAT ALL CONDUCTOR BENDS HAVE AT LEAST
AN 8" RADIUS AND NOT LESS THAN 90 DEGREE BEND ANGLE.
3. CONDUIT CONTAINING THE LIGHTNING PROTECTION SHALL BE
SURFACED MOUNTED WITHIN CONTROLLED SPACE AS IT PASSES
THROUGH.
4. ROOF CONDUCTORS SHALL BE CONCEILED. PENETRATIONS
SHALL BE IN ACCORDANCE WITH ROOF MANUFACTURER'S
RECOMMENDATIONS AND WARRANTY.
5. ALL DOWN CONDUCTORS SHALL BE CONCEALED WITHIN WALLS.
EXCEPT IN THE CONTROLLED AREA.
6. THE LIGHTNING PROTECTION INSTALLERS SHALL COORDINATE
WITH THE ROOF INSTALLERS CONCERNING REQUIREMENTS FOR
DIFFERING METALS.
7. CONNECTIONS TO THE STRUCTURAL STEEL FRAMEWORK SHALL
BE MADE AT AREAS THAT HAVE BEEN CLEANED TO THE BASE
METAL BY USE OF BONDING PLATES (HAVING A SURFACE
CONTACT AREA OF NOT LESS THAN 8 SQ-IN) OR BY WELDING OR
BRAZING. WHERE RUST-PROTECTIVE COATING OF PAINT IS
REMOVED, THE BASE STEEL SHALL BE PROTECTED WITH A
CONDUCTIVE, CORROSION-INHIBITING COATING.
8. PROVIDE PVC SLEEVE WHEREVER GROUNDING CONDUCTOR
MUST PASS THROUGH EXTERIOR WALL, CONCRETE PAD, SLAB,
OR FOUNDATION GRADE BEAM.
9. PROVIDE A COUNTERPOISE CONSISTING OF A #4/0 AWG BARE
COPPER CONDUCTOR A MINIMUM OF 30" BELOW FINISHED
GRADE AND 5'-0" FROM THE BUILDING'S EXTERIOR WALL.
10. GROUND RODS SHALL BE INSTALLED MINIMUM 2'-6" BELOW
GRADE AND MINIMUM 2'-0" FROM FOUNDATION WALL. GROUND
RODS SHALL PENETRATE EARTH AT LEAST 10'-0".
11. INTERCONNECT LIGHTNING PROTECTION SYSTEM TO THE
ELECTRICAL SERVICE GROUND, COMMUNICATIONS GROUND,
AND ALL UNDERGROUND METALLIC PIPING SYSTEMS IN
ACCORDANCE WITH THE NEC, ARTICLE 250.
12, SEE SHEET EG502 FOR ADDITIONAL REQUIRED CONNECTIONS
TO THE COUNTERPOISE.
13. ALL METALLIC ROOF PENETRATIONS WITH METAL EQUAL TO
OR GREATER THAN 0.1875-INCHES THICK SHALL BE BONDED
TO THE LIGHTNING PROTECTION SYSTEM, UNLESS LOCATED
UNDER THE ZONE OF PROTECTION. ALL NON-METALLIC ROOF
PENETRATIONS AND ALL METALLIC ROOF PENETRATIONS WITH
METAL LESS THAN 0.1875-INCHES THICK SHALL BE PROVIDED
WITH AIR TERMINALS CONNECTED TO THE ROOF CONDUCTORS,
UNLESS LOCATED UNDER THE ZONE OF PROTECTION.
COORDINATE WITH OTHER TRADES FOR ROOF PENETRATION
LOCATIONS.
14. BOND ALL ANTENNAS AND SUPPORTS TO THE LIGHTNING
GENERAL NOTES:
1 2 4 5
A
B
C
D
E
TW
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
FOR OFFICIAL USE ONLY (FOUO)
FOR OFFICIAL USE ONLY (FOUO)
FO
R
O
FF
IC
IA
L U
SE
O
N
LY
(F O
U O
C:\Users\K6ENDRB9\Documents\FY16PN79439ITF_MEP_R15_K6ENDRB9.rvt
3/19/2018 3:14:34 PM
M
AR
C H
W
2P M
-1 8-
R -0
XX
XX
X-
XX
-X -X
XX
X
R . B
R
IT
O
- J.
S
TE
IN
1-
-0
EG112
LI
G
H
TN
IN
G
P R
O T E
C
TI
O N
P
LA
N
AR
EA
B
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
6 9 D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
, N C
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
N U
E
SA
VA
N
N
AH
, G A
FO
R
T
BR
AG
G
, N O
R T H
C
AR
O
LI
N A
P N
AD
VA
N C
ED
S
KI
LL
S
TR
A I N
IN
G
F
AC
IL
IT
Y
R . D
AV
IS
ISSUED FOR CONSTRUCTION
Roof_Lightning Protection_WORK - AREA B1
KEY PLAN
A
B
PLAN NORTH
M
AR
K D
ES
C
R
IP
TI
O
N D
SEE ARCHITECT FOR
WALLS DETAILS
FINISHED FLOOR
VA
R
IE
S
FINISHED GRADE
8'-0" MAX
3'-0" MIN
3'-0" MIN
GROUND ROD
2' -0
" M
IN
EXOTHERMIC WELD COUNTERPOISE AND
DOWN CONDUCTOR TO GROUND ROD.
CLASS 1 BARE COPPER
DOWN CONDUCTOR PROVIDE 1-1/4"
DIA. HOLE IN
BASEPLATE
STEEL
COLUMN
EXOTHERMIC WELD
TO STEEL
3/4" SCHEDULE 80
PVC CONDUIT
8" RADIUS
MIN
COUNTER-
PIOSE
GROUND CONNECTION TO STRUCTURE
BARE STRANDED COPPER CABLE
GROUND COUNTERPOISE &
LEAD CONDUCTORS
EXOTHERMICLY CONNECT CABLES
TO GROUND ROD
3/4"x10' COPPER CLAD
STEEL GROUND ROD
RATED FOR USE IN TRAFFIC AREAS
LIFTING EYE REINFORCED CONCRETE
COVERGRADE
BOLTED CABLE CONNECTOR
6" LAYER SAND
GROUND ROD
8" CLAY PIPE
36" LONG
GROUND COUNTERPOISE &
LEAD CONDUCTORS
N G
TMGB
1. GROUNDING SHALL BE IN
ACCORDANCE WITH NEC
ARTICLE 250. VARIATIONS
TO GROUNDING SHOWN
SHALL BE APPROVED
BY THE CONTRACTING
OFFICER'S REPRESENTATIVE.
2. CONDUCTORS SHALL BE
SIZED BASED ON THE
REQUIREMENTS OF NEC
ARTICLE 250.
STRUCTURAL
STEEL
METALLIC
(WHEN USED)
ENTRANCE
WATER PIPE
FOOTING REINFORCEMENT
(CONCRETE-ENCASED
ELECTRODE)
FOOTING
GROUND ROD
(MADE ELECTRODE)
SEE LIGHTNING
PROTECTION
SYSTEM
COUNTERPOISE
SEE T-DRAWINGS
FOR ADDITIONAL
GROUNDING
REQUIREMENTS
METALLIC
(WHEN USED)
ENTRANCE
GAS PIPE
MGB
MDP
COPPER GROUNDING
BUSBAR
GROUNDING LUG
MOUNTING HOLES
STANDOFF
MOUNTING
BRACKET
INSULATOR
GROUNDING
LUG
MAIN GROUND BUS (TMGB)
1.FOR ELECTRICAL NOTES, ABBREVIATIONS, AND SYMBOLS
REFER TO DRAWING E-001.
2. GROUNDING BUSBARS SHALL BE A MINIMUM 1/4" THICK, (2"
WIDE - TGB) AND (4" WIDE - TMGB) WITH LENGTH AS REQUIRED
AND SHALL BE INSULATED FROM
ITS SUPPORTS BY A MINIMUM OF 2”. THE COPPER BUSBARS
SHALL BE A PRE-DRILLED WITH STANDARD NEMA BOLT HOLE
SIZING AND SPACING FOR THE TYPE AND SIZE OF CONDUCTOR
BEING USED. THE BUSBARS SHALL BE CLEANED PRIOR
TO FASTENING OF CONDUCTORS AND AN ANTI-OXIDANT
SHOULD BE APPLIED TO THE CONTACT AREA TO CONTROL
CORROSION AND REDUCE CONTACT RESISTANCE. THE
BUSBARS SHALL BE MOUNTED AT 18 INCH ABOVE FINISHED
FLOOR UNLESS
OTHERWISE INDICATED.
3. POWER SYSTEM BONDING CONDUCTORS SHALL BE SIZED IN
ACCORDDANCE WITH NFPA 70 AND NFPA 780.
* ARE NOT SHOWN. SEE PLANS AND SPECIFICATIONS FOR
ADDITIONAL GROUNDING CONDUCTORS OR REQUIREMENTS.
NOTES:
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
FOR OFFICIAL USE ONLY (FOUO)
FOR OFFICIAL USE ONLY (FOUO)
FO
R
O
FF
IC
IA
L U
SE
O
N
LY
(F O
U O
C:\Users\K6ENDRB9\Documents\FY16PN79439ITF_MEP_R15_K6ENDRB9.rvt
3/19/2018 3:14:42 PM
M
AR
C H
W
2P M
-1 8-
R -0
XX
XX
X-
XX
-X -X
XX
X
R . B
R
IT
O
- J.
S
TE
IN
1-
-0
EG501
LI
G
H
TN
I N G
P R
O
TE
C
TI
O N
D
ET
A I
LS
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
6 9 D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
, N C
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
N U
E
SA
VA
N
N
AH
, G A
FO
R
T
BR
AG
G
, N O
R T H
C
AR
O
LI
N A
P N
AD
VA
N C
ED
S
KI
LL
S
TR
A I N
IN
G
F
AC
IL
IT
Y
R . D
AV
IS
ISSUED FOR CONSTRUCTION
#TYPICAL COLUMN GROUNDING DETAIL1 #TYPICAL GROUND ROD CONNECTION DETAIL2 #TYPICAL GROUND ROD TEST WELL DETAIL3
#TYPICAL SYSTEM GROUND AT MDP4 TELECOMMUNICATIONS GROUND BUS5
M
AR
K D
ES
C
R
IP
TI
O
N D
VERTICALLY MOUNTED AIR TERMINAL ON PARAPET.
HORIZONTALLY MOUNTED AIR TERMINAL ON FLAT ROOF.
AIR TERMINALS MOUNTED ON MECHANICAL EQUIPMENT
ENCLOSURE.
AIR TERMINAL MOUNTED ON EXHAUST FAN (`DEAD-END'
METHOD).
AIR TERMINAL MOUNTED ON GUARDRAIL WITH PIPE
RAILING BASE.
BOND WINDOW, DOOR FRAMES, ROOF ACCESS HATCHES,
LADDERS, ANTENNAS AND OTHER METALLIC OBJECTS WITH
BONDING LUGS AND SECONDARY CONDUCTOR.
CABLE CLIP WITH STAINLESS STEEL SCREWS EVERY 3 FEET
MAXIMUM SPACING.
AIR TERMINAL ON SKYLIGHT WITH SADDLE TYPE AIR
TERMINAL BASE (WHERE APPLICABLE).
1. PROVIDE CERTIFICATION FROM A COMMERCIAL THIRD-PARTY INSPECTION COMPANY WHOSE
SOLE WORK IS LIGHTNING PROTECTION, STATING THAT THE LIGHTNING PROTECTION SYSTEM
COMPLIES WITH NFPA 780. THE THIRD PARTY INSPECTION COMPANY CANNOT BE THE SYSTEM
INSTALLER OR THE SYSTEM DESIGNER. ALTERNATIVELY, PROVIDE A UL LIGHTNING PROTECTION
INSPECTION MASTER LABEL CERTIFICATE FOR EACH FACILITY INDICATING COMPLIANCE TO
NFPA 780.
2. ALUMINUM LIGHTNING PROTECTION SYSTEM COMPONENTS SHALL NOT BE MOUNTED TO
COPPER SURFACES. COPPER COMPONENTS SHALL BE USED TO AVOID ELECTROLYTIC CORROSION.
3. METAL BODIES WITHIN 6' - 0" OF THE LIGHTNING PROTECTION SYSTEM SHALL BE BONDED
TO THE SYSTEM IN ACCORDANCE WITH UL96A. METAL PARTS FURTHER THAN 6 FEET SHALL
ALSO BE BONDED IF THEY ARE WITHIN 6 FEET OF A METAL PART THAT IS BONDED TO THE
LIGHTNING PROTECTION SYSTEM.
4. UNDERGROUND METALLIC PIPING ENTERING THE BUILDING SHALL BE BONDED TO THE
NEAREST DOWN CONDUCTOR OR GROUND ELECTRODE.
5. AIR TERMINALS SHALL BE LOCATED ON THE ROOF TOP EQUIPMENT. (AN EXCEPTION IS
ALLOWABLE IF THE METAL THICKNESS OF AN OBJECT IS 3/16" OR GREATER AND THE OBJECT
IS PROPERLY CONNECTED TO THE SYSTEM.)
6. ALL LIGHTNING CONDUCTORS ARE TO MAINTAIN A HORIZONTAL OR DOWNWARD PATH.
ALL BENDS IN THE CONDUCTOR SHALL HAVE A RADIUS BEND OF 8 INCHES OR GREATER,
AND SHALL HAVE AN ANGLE BEND OF 90 DEGREES OR GREATER.
7. ROOF PADS, PAVERS, FLASHINGS OR ANY OTHER SPECIAL ROOFING MATERIALS REQUIRED
FOR THE INSTALLATION OF THE LIGHTNING PROTECTION SYSTEM SHALL BE FURNISHED AND
INSTALLED BY THE ROOFING CONTRACTOR.
8. FLEXIBLE EPDM PIPE FLASHING WITH PLEATED BOOT AND BONDED ALUMINUM REINFORCING
RING SHALL BE PROVIDED AT THRU-ROOF PENETRATIONS. FLASHING BOOT SHALL BE SET IN
SEALANT AND REINFORCING RING SHALL BE SCREWED ATTACHED TO RIDGE CAP OR ROOF PANEL
AS INDICATED. FLASHING BOOTS SHALL BE INSTALLED BY THE ROOFING CONTRACTOR.
9. AIR TERMINALS SHALL BE CENTERED ON RIDGE AT RIDGE CAP.
GENTLY TAPERED
AIR TERMINAL
UNIVERSAL FLAT
SURFACE AIR
TERMINAL BASE
MOUNTED
HORIZONTALLY
THRU-ROOF CONNECTOR.
LIGHTNING DOWN CONDUCTOR.MAIN LIGHTNING CONDUCTOR.
CABLE CONNECTOR.
CABLE FASTENER.
NOT TO SCALE
UNIVERSAL FLAT
SURFACE AIR TERMINAL
BASE MOUNTED
VERTICALLY
CABLE FASTENER
AIR TERMINAL
BASE EXTENSION
GENTLY TAPERED
AIR TERMINAL
ROOF RIDGE AIR TERMINAL - CONCEALED CONDUCTOR
THRU-ROOF PENETRATION
THRU-ROOF
CONNECTOR THRU-WALL
CONNECTOR
THRU-WALL PENETRATION
RIDGE SADDLE
AIR TERMINAL
BASE
CABLE FASTENER
RIDGE ROOF AIR TERMINAL - EXPOSED CONDUCTOR
GENTLY TAPERED
AIR TERMINAL
CABLE FASTENER
CONCEALED RIDGE
AIR TERMINAL BASE
AIR TERMINAL
ADAPTER
GENTLY TAPERED
AIR TERMINAL
FLAT ROOF AIR TERMINAL - EXPOSED CONDUCTOR PARAPET WALL AIR TERMINAL - EXPOSED CONDUCTOR
MISCELLANEOUS LIGHTNING PROTECTION SYSTEM CONNECTIONS
NOTE: BONDING DETAILS AND AIR TERMINAL
LOCATIONS SHOWN ARE TYPICAL, GENERAL
EXAMPLES ONLY. FINAL EXTENT OF BONDING
AND SPECIFIC FITTING APPLICATIONS TO BE
DETERMINED IN FIELD BASED ON ACTUAL
SITE CONDITIONS.
LIGHTNING PROTECTION SYSTEM NOTES
LIGHTNING PROTECTION
DOWN CONDUCTOR
EXOTHERMIC WELD TO
CLEANED BARE STEEL
SURFACE
EXOTHERMIC WELD TO
CLEANED BARE STEEL
SURFACE
LIGHTNING PROTECTION
CONDUCTOR
1" SCH 40 PVC SLEEVE
THROUGH FLOOR FOR
CONNECTION OF PERIMETER
STEEL COLUMN GROUND.
SEAL SLEEVE AS REQUIRED
AFTER INSTALLATION OF
GROUND CONDUCTOR.LIGHTNING
PROTECTION
CONDUCTOR TO LOOP
CONDUCTOR AND GROUND ROD
COLUMN CONNECTION - TOP
COLUMN CONNECTION - BOTTOM
CABLE FASTENER
(ADHESIVE WHERE
INSTALLED ON EPDM
TYPE ROOF)
LIGHTNING
PROTECTION
MAIN CONDUCTOR
LIGHTNING
PROTECTION
MAIN CONDUCTOR
LIGHTNING
PROTECTION
MAIN CONDUCTOR
LIGHTNING
PROTECTION
MAIN CONDUCTOR
LIGHTNING
PROTECTION
MAIN CONDUCTOR
LIGHTNING PROTECTION
MAIN CONDUCTOR
LIGHTNING
PROTECTION
MAIN CONDUCTOR
LIGHTNING
PROTECTION
MAIN CONDUCTOR
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
FOR OFFICIAL USE ONLY (FOUO)
FOR OFFICIAL USE ONLY (FOUO)
FO
R
O
FF
IC
IA
L U
SE
O
N
LY
(F O
U O
C:\Users\K6ENDRB9\Documents\FY16PN79439ITF_MEP_R15_K6ENDRB9.rvt
3/19/2018 3:14:48 PM
M
AR
C H
W
2P M
-1 8-
R -0
XX
XX
X-
XX
-X -X
XX
X
R . B
R
IT
O
- J.
S
TE
IN
1-
-0
EG502
LI
G
H
TN
I N G
P R
O
TE
C
TI
O N
D
ET
A I
LS
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
6 9 D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
, N C
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
N U
E
SA
VA
N
N
AH
, G A
FO
R
T
BR
AG
G
, N O
R T H
C
AR
O
LI
N A
P N
AD
VA
N C
ED
S
KI
LL
S
TR
A I N
IN
G
F
AC
IL
IT
Y
R . D
AV
IS
ISSUED FOR CONSTRUCTION
M
AR
K D
ES
C
R
IP
TI
O
N D
ADJUSTABLE
BONDING STRAP
NON-METALLIC
PLUMBING
VENT PIPE
BONDING
CONDUCTOR
10" MIN
AIR TERMINAL
AIR TERMINAL
MOUNTING
BRACKET
NON-METALLIC
PLUMBING
VENT PIPE
MAIN
CONDUCTOR
AIR TERMINAL
10"
MIN
BONDING PLATE
PARALLEL
CLAMP
MAIN
CONDUCTOR
SIDE MOUNT
MECHANICALLY
FASTENED AIR
TERMINAL BASE
PROVIDE REINFORCED CONCRETE
GROUND INSPECTION WELL WITH CAST
IRON LID MARKED "GROUND". MOUNT
WELL FLUSH WITH FINISHED GRADE.
COPPER CLAD GROUND ROD. THE
POINT SHALL BE MADE AT A POINT
NOT LESS THAN 18" BELOW GRADE
AND A MINIMUM OF 24" AWAY FROM
FOOTINGS OR FOUNDATION WALLS.
GROUND CONNECTION
TO STRUCTURE
MAIN CONDUCTOR (COUNTERPOISE
LOOP)
MECHANICAL CLAMPING
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
FOR OFFICIAL USE ONLY (FOUO)
FOR OFFICIAL USE ONLY (FOUO)
FO
R
O
FF
IC
IA
L U
SE
O
N
LY
(F O
U O
C:\Users\K6ENDRB9\Documents\FY16PN79439ITF_MEP_R15_K6ENDRB9.rvt
3/19/2018 3:14:54 PM
M
AR
C H
W
2P M
-1 8-
R -0
XX
XX
X-
XX
-X -X
XX
X
R . B
R
IT
O
- J.
S
TE
IN
1-
-0
EG503
LI
G
H
TN
I N G
P R
O
TE
C
TI
O N
D
ET
A I
LS
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
6 9 D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
, N C
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
N U
E
SA
VA
N
N
AH
, G A
FO
R
T
BR
AG
G
, N O
R T H
C
AR
O
LI
N A
P N
AD
VA
N C
ED
S
KI
LL
S
TR
A I N
IN
G
F
AC
IL
IT
Y
R . D
AV
IS
ISSUED FOR CONSTRUCTION
METALLIC VENT PIPE DETAIL11 NON-METALLIC VENT PIPE12 FLUE VENT CAP AIR TERMINAL13 GROUND ROD TEST WELL14
M
AR
K D
ES
C
R
IP
TI
O
N D
FD
LV
osos os
LV
LV
OS
OS
OS
OSOS
OS
OS
OS
OS
OS OS
OS
OS OS
OSOS
OS
OS
LV
LV
LV
DK
D
KD
K
LV
LV
LV
os
DC
OS
OS
OS
OS
O S
MS
OS
O S
LV
dc db da
D C D
C
OS
OS
1 2 3 4 5
E
F
G
H
DISINTEGRATOR
SUPPLY
OFFICE
SUPPLY / FILES
CORRIDOR
RECEIVING /
LOADING
LACTATION
LOBBY
ESS TR
BADGING
CORRIDOR
STOR
SIPR TR
STOR
ELEV 1
ELEV 2
R2H
R2H
R2H
R2H
R2H
R2He
R2H
R2H
R2H
R2H
R2He
R2H
R2He
R2H
R2He
R2H
R2HR2He V4Le
V4L
T1
T1 T3e T3e
T3e T3
R2L
T3
V4L
V4Le
V4L V4L
R2L
R2L
R2Le R2L
R2Le
R2L
T1
FM OFC &
SUPPLY
STORAGE
T1 T1e
T1 T1
V4Le
V4Le V4LV4L
V4HV4H
R2H R2H
R2HR2He
T3e
T3
T3e
T3T3
T3
V2Ae
V2Ae
R 8L
E-
V2Ae
V2Ae
V2A V2Ae
V2Ae
V2A V2A
V2A
V2A
V2A
V2Ae
V2A
V2A
V2A
V2A T3
V2L V2Le
LP1 -12
LP1 -15
LP1 -3
LP1 -5
ELP-1
-7LP1 -9
ELP-1
-4
N2e
S9 VP1
VP1
LP1 -10
V4H V4H
V4H V4H
S1
S1
S1
S2S2
S1
S1
S9
S9
S9
S15
S15
S15
S3S3 S3
S1
S1
S5
S1
S4S1
S1
S1
S1
S16
S5
S14
S5
S3S4 a b c f f
LP1 -6T2
R 8L
-8
FIRE PUMP
ELECTRICAL
WAITING /
CELLPHONE
SECURITY
A CO STORAGE
VEST
ELEVATOR
LOBBY
STORAGE
STAIR 1
EL EQ RM
CORRIDOR
CLASSROOM
CLASSROOM
122CORRIDOR
CLASSROOM
R2H
R2L R2L
S4
S14
S9
S9
V2L
V2L V2L V2L
V2L V2Le V2L
V2L V2L V2L
V2L V2Le V2L
V2Le V2L
V2L V2L
V2L V2L
V2L V2L
V2L V2L
V2L V2L V2L
V2L V2Le V2L
V2L V2L V2L
V2L V2Le V2L
V2L V2Le
LP1 -8
V2Le
V4LV4L
V4LV4L
V4L
V4L
V4L
LP1 -2
f
D12
D12 D12
D12
D12
LP1 -16
V2L
V2L
V2Le
V2L
V2Le
V2L
LP1 -17
S14
S14
S14
S14
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
FOR OFFICIAL USE ONLY (FOUO)
FOR OFFICIAL USE ONLY (FOUO)
FO
R
O
FF
IC
IA
L U
SE
O
N
LY
(F O
U O
C:\Users\K6ENDRB9\Documents\FY16PN79439ITF_MEP_R15_K6ENDRB9.rvt
3/19/2018 3:15:09 PM
M
AR
C H
W
2P M
-1 8-
R -0
XX
XX
X-
XX
-X -X
XX
X
R . B
R
IT
O
- J.
S
TE
IN
1-
-0
EL111
LI
G
H
TI
N G
P
LA
N
FI
R
ST
F
LO
O
R
AR
EA
A
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
6 9 D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
, N C
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
N U
E
SA
VA
N
N
AH
, G A
FO
R
T
BR
AG
G
, N O
R T H
C
AR
O
LI
N A
P N
AD
VA
N C
ED
S
KI
LL
S
TR
A I N
IN
G
F
AC
IL
IT
Y
R . D
AV
IS
ISSUED FOR CONSTRUCTION
KEY PLAN
A
B
PLAN NORTH
NOTES:
1. SEE DRAWING E001 FOR ELECTRICAL LEGEND, GENERAL NOTES AND
TYPICAL MOUNTING HEIGHTS AND SEPARATION DISTANCES.
2. SEE DRAWINGS EL500 SERIES FOR LIGHTING FIXTURES SCHEDULES
AND DETAILS.
3. SEE DRAWINGS EL600 SERIES FOR LIGHTING CONTROL STRATEGIES
AND NOTES.
4. SEE A-PLATES FOR REFLECTED CEILING PLANS SHOWING LOCATIONS
OF FIXTURES AND DEVICES IN CEILING GRID.
5. HOMERUN (CIRCUIT) DESIGNATIONS INDICATED IN SPACES APPLY TO
ALL LIGHTING FIXTURES WITHIN THOSE SPACES UNLESS OTHERWISE
INDICATED.
1st Floor Lighting Plan -AREA A1
M
AR
K D
ES
C
R
IP
TI
O
N D
FD FD
FD
FDFD
FD
FD FD
FD FD
FD
FD
FD os os
LV LV
os
OS
OS
OSOS
OS
OS
OS OS
OS
OS OS
OS
OSOS
OS OSOS
OS OS
OS
OS
OS
OS
OS
O S
O S
OS
OS
O S
O S
LV
LV
LV LV LV
D K
D K
LV
LV LV
MS
OSOS
os
OS
OS
OS
LV
O S O S
OS
DC
LV
LV
O S
1 2 3 4 5
A
B
D
E
C
CONFERENCE /
VTC
OTD 3
OTD 2
OTD 1
VEST
CLASSROOM
CORRIDOR
CORRIDOR
CORRIDOR
STOR
NOIC OFFICE
OPEN OFFICE
SERVER ROOM
VEST.
SSR OFFICE
MECHANICAL
NIPR TR
SIPR TR
UPS
JAN
RECYCLE
STORAGE
MEN
WOMEN
PM OFFICE
OIC OFFICE
STAIR 2
STORAGE
STORAGE
V4L V4L
V4L V4L
V4L V4Le
R8Ld-4
R8Ld-4
R8Ld-4
R8Ld-4
R8Ld-4 R8Ld-4e
R8Ld-4
R8Ld-4
R8Ld-4
R8Ld-4
R1Hd R1Hd
R1Hd R1Hd
R1Hd R1Hde
V2L
V2Le V2LV2L
T3 T2e T2e T2e
T2e T2e T2e
V4L V4L
R2He
R2H
R2H
R2H
R2H
R2H
R2He
R2H
R2H
R2He
R2H
R2H
R2H
R2H
R2H
R2He
R2H
R2H
R2H
R2H
R2H
V4H V4H V4H V4H
R7Le R7Le R7Le
R7L
R7Le
R7L
R7L R7Le
R7L
R7LeR7L
R7LR7L
R7L R7Le
R7L
R7L
R7Le
D1 D1 D1
D1D1D1D1D1D1
R7Le
T3e
T3e
T3eT3e
T3e
T3e
T3
T3
T3
T3
T3
T3
T3e T3e
T3 T3
T3 T3T3T3
T3
T3
T3
T3e
T3e
T3e
T3e T3e
T3e
T3e
V2Ae
V2Ae
V2Ae
V2Ae
V2Ae V2Ae
V2Ae
T1
V2Ae V2A
V2Ae
V2Ae
V2Ae V2Ae V2A
V2A
V2A
V2A
V2A V2A
V2A
V2A
V2Ae
V2A
V2A
V2A
V2AV2AeV2A
V2A-3e
V2A-3 V2A-3 V2A-3 V2A-3
V2A-3 V2A-3 V2A-3e
V2A-3 V2A-3 V2A-3V2A-3V2A-3
V2A-3
V2A-3e V2A-3V2A-3V2A-3e
V2A-3 V2A-3 V2A-3
V2A-3V2A-3
V2A-3 V2A-3 V2A-3e
V2A-3V2A-3e
V2A-3 V2A-3 V2A-3V2A-3
LP1 -1
LP1 -11
LP1 -21
LP1 -19 LP1 -18
ELP-1
-1
LP1 -22 ELP-1
-2
V2A V2Ae
LP1 -23
LP1 -24
ELP-1
-5
LP1 -7
AV
STOR
S1
S1
S1
S1
S7
S5
S8
S8
S5 S5
S3
S5 S5
S1
S1
S4 S4
S10
S9
S9
S9
S13
S13
S3
S3
S3
S1
S9
LP1 -22
LP1 -20
LP1 -14
LP1 -13
V2L
S14
T2
T2
S9
V2A-3
V2A-3 V2A-3 V2A-3V2A-3
V2L V2L
S1
S1
S1
S1
V4L V4L
V4L V4L
V4L V4L
V4L V4L
V4LV4Le
V4L V4L
V4L V4L
V4L V4L
V4L V4L
V4L V4Le
V4L V4L
V4L V4L
R7L
LP1 -18
V2A-3
V2A-3
V2A-3
S14
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
FOR OFFICIAL USE ONLY (FOUO)
FOR OFFICIAL USE ONLY (FOUO)
FO
R
O
FF
IC
IA
L U
SE
O
N
LY
(F O
U O
C:\Users\K6ENDRB9\Documents\FY16PN79439ITF_MEP_R15_K6ENDRB9.rvt
3/19/2018 3:15:19 PM
M
AR
C H
W
2P M
-1 8-
R -0
XX
XX
X-
XX
-X -X
XX
X
R . B
R
IT
O
- J.
S
TE
IN
1-
-0
EL112
LI
G
H
TI
N G
P
LA
N
FI
R
ST
F
LO
O
R
AR
EA
B
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
6 9 D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
, N C
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
N U
E
SA
VA
N
N
AH
, G A
FO
R
T
BR
AG
G
, N O
R T H
C
AR
O
LI
N A
P N
AD
VA
N C
ED
S
KI
LL
S
TR
A I N
IN
G
F
AC
IL
IT
Y
R . D
AV
IS
ISSUED FOR CONSTRUCTION
KEY PLAN
A
B
PLAN NORTH
NOTES:
1. SEE DRAWING E001 FOR ELECTRICAL LEGEND, GENERAL NOTES AND
TYPICAL MOUNTING HEIGHTS AND SEPARATION DISTANCES.
2. SEE DRAWINGS EL500 SERIES FOR LIGHTING FIXTURES SCHEDULES
AND DETAILS.
3. SEE DRAWINGS EL600 SERIES FOR LIGHTING CONTROL STRATEGIES
AND NOTES.
4. SEE A-PLATES FOR REFLECTED CEILING PLANS SHOWING LOCATIONS
OF FIXTURES AND DEVICES IN CEILING GRID.
5. HOMERUN (CIRCUIT) DESIGNATIONS INDICATED IN SPACES APPLY TO
ALL LIGHTING FIXTURES WITHIN THOSE SPACES UNLESS OTHERWISE
INDICATED.
1st Floor Lighting Plan -AREA B1
M
AR
K D
ES
C
R
IP
TI
O
N D
UP
FD
UP
UP
PS
T
PS
T
PS
T
PS
T
PS
T
PS
T
PS
T
PS
T
PS
T
PS
T
W
PS
T
W
W
W
W
W
W
LV
LV
LV
LV
LV
LV
LV
LV
D K
D K
D K
D K os
LV
LV LV LV
OS
OS
OS
OS
OS
OS
OSOS
OS
OS
OS
OS
OS
OS
OS
OSOS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
O S
O S O S
OS
OS
OS
O S
LV
OS
OS
DC
DC
DC
OSOS
LV
1 2 3 4 5
E
F
G
H
CLASSROOM
ELECTRICAL
CORRIDOR
CORRIDOR
UWCEI /
UWODC / UNDC
/ OPEN OFFICE
STORAGE
CMDR OFFICE
TOILET
XO OFFICE
1SG OFFICE
SUPPLY
OFFICE
SUPPLY
STORAGE
B CO HQ OPEN
OFFICE /
WAITING
STAIR 1
SIPR TR
NIPR TR
AV
STORAGE
CORRIDOR
ELEV 1
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.