ADV_PLANS_PN80773_Vol2.pdf
PDF 47 MB Posted
- Attached to
- PN80773 SOF Battalion Operations Facility Federal contract opportunity
- Solicitation number
- W912PM-16-R-0020
About this file
PLANS - Volume 2
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_0005_PN80773.pdf | ||
| Amd4_PN80773_W912PM-16-R-0020.pdf | ||
| AMD0003_PN80773_PLANS_Vol1.pdf | ||
| AMD0003_PN80773_PLANS_Vol2.pdf | ||
| AMD0003_PN80773_PLANS_Vol1_CADDfiles.zip | ZIP file | |
| PN_80773_-_Amendment_0003.pdf | ||
| W912PM-16-R-0020-0002__PN80773.pdf | ||
| AMD0002_PLANS_PN80773_VOL1_Caddfiles.zip | ZIP file | |
| AMD0002_PLANS_PN80773_VOL1.pdf | ||
| AMD0002_PLANS_PN80773_VOL2.pdf | ||
| AMD0001_PLANS_PN80773_V1.pdf | ||
| Amendment_0001_-_PN_80773.pdf | ||
| AMD0001_PLANS_PN80773_V1_Caddfiles.zip | ZIP file | |
| AMD0001_PLANS_PN80773_V2.pdf | ||
| Site_Visit_Sign-In.pdf | ||
| BR80773vol2.pdf | ||
| BR80773vol4-FF E.pdf | ||
| ADV_PLANS_PN80773_Vol1.pdf | ||
| BR80773vol1.pdf | ||
| BR80773vol3.pdf |
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET ID. TITLE
INDEX OF DRAWINGS - VOLUME
SHEET ID. SHEET ID.TITLE TITLE
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
F:\Revit Local\FY16PN80773BOF_PROJECT_R15_K6ENDKRW.rvt
7/1/2016 6:50:30 AM
JU
LY
- W
2P M
-1 6-
R -0
1-
-2
GI001
IN
D
EX
O
F D
R A W
IN
G
S
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
6 9 D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
, N O
R
TH
C
AR
O
LI
N A
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SA
VA
N N
AH
D
IS
TR
IC
T
W
ES
T O
G
LE
TH
O
R
PE
A
VE
N U
E
SA
VA
N
N
AH
, G
EO
R G
IA
FO
R
T
BR
AG
G
, N O
R T H
C
AR
O
LI
N A
S O F
BA
T T
AL
IO
N O
PE
R
A T
IO
N S
F A C
IL
IT
Y P N
VO
L U M
E
O F
RTA SUBMITTAL
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
FA111 FIRE ALARM AND MNS FLOOR PLAN - FIRST FLOOR - PART A
FA112 FIRE ALARM AND MNS FLOOR PLAN - FIRST FLOOR - PART B
FA113 FIRE ALARM AND MNS FLOOR PLAN - FIRST FLOOR - PART C
FA114 FIRE ALARM AND MNS FLOOR PLAN - FIRST FLOOR - PART D
FA115 FIRE ALARM AND MNS FLOOR PLAN - FIRST FLOOR - PART E
FA121 FIRE ALARM AND MNS FLOOR PLAN - SECOND FLOOR - PART A
FA122 FIRE ALARM AND MNS FLOOR PLAN - SECOND FLOOR - PART B
FA123 FIRE ALARM AND MNS FLOOR PLAN - SECOND FLOOR - PART C
FA124 FIRE ALARM AND MNS FLOOR PLAN - SECOND FLOOR - PART D
FA125 FIRE ALARM AND MNS FLOOR PLAN - SECOND FLOOR - PART E
FA601 FIRE ALARM AND MNS DIAGRAM
FX001 FIRE PROTECTION LEGEND AND GENERAL NOTES
FX111 FIRE PROTECTION - 1ST FLOOR - PART A
FX112 FIRE PROTECTION - 1ST FLOOR - PART B
FX113 FIRE PROTECTION - 1ST FLOOR - PART C
FX114 FIRE PROTECTION - 1ST FLOOR - PART D
FX115 FIRE PROTECTION - 1ST FLOOR - PART E
FX121 FIRE PROTECTION - 2ND FLOOR - PART A
FX122 FIRE PROTECTION - 2ND FLOOR - PART B
FX123 FIRE PROTECTION - 2ND FLOOR - PART C
FX124 FIRE PROTECTION - 2ND FLOOR - PART D
FX125 FIRE PROTECTION - 2ND FLOOR - PART E
FX501 FIRE PROTECTION DETAILS I
FX502 FIRE PROTECTION DETAILS II
FX503 FIRE PROTECTION DETAILS III
P-001 PLUMBING LEGEND
PL111 PLUMBING FLOOR PLAN - DOMESTIC - 1ST FLOOR - PART A
PL112 PLUMBING FLOOR PLAN - DOMESTIC - 1ST FLOOR - PART B
PL113 PLUMBING FLOOR PLAN - DOMESTIC - 1ST FLOOR - PART C
PL114 PLUMBING FLOOR PLAN - DOMESTIC - 1ST FLOOR - PART D
PL115 PLUMBING FLOOR PLAN - DOMESTIC - 1ST FLOOR - PART E
PL121 PLUMBING FLOOR PLAN - DOMESTIC - 2ND FLOOR - PART A
PL122 PLUMBING FLOOR PLAN - DOMESTIC - 2ND FLOOR - PART B
PL123 PLUMBING FLOOR PLAN - DOMESTIC - 2ND FLOOR - PART C
PL124 PLUMBING FLOOR PLAN - DOMESTIC - 2ND FLOOR - PART D
PL125 PLUMBING FLOOR PLAN - DOMESTIC - 2ND FLOOR - PART E
PL131 PLUMBING FLOOR PLAN - SANITARY - 1ST FLOOR - PART A
PL132 PLUMBING FLOOR PLAN - SANITARY - 1ST FLOOR - PART B
PL133 PLUMBING FLOOR PLAN - SANITARY - 1ST FLOOR - PART C
PL134 PLUMBING FLOOR PLAN - SANITARY - 1ST FLOOR - PART D
PL135 PLUMBING FLOOR PLAN - SANITARY - 1ST FLOOR - PART E
PL141 PLUMBING FLOOR PLAN - SANITARY - 2ND FLOOR - PART A
PL142 PLUMBING FLOOR PLAN - SANITARY - 2ND FLOOR - PART B
PL143 PLUMBING FLOOR PLAN - SANITARY - 2ND FLOOR - PART C
PL144 PLUMBING FLOOR PLAN - SANITARY - 2ND FLOOR - PART D
PL145 PLUMBING FLOOR PLAN - SANITARY - 2ND FLOOR - PART E
PL401 PLUMBING ENLARGED PLANS
PL402 PLUMBING ENLARGED PLANS
PL403 PLUMBING ENLARGED PLANS
PL404 PLUMBING ENLARGED PLANS
PL501 PLUMBING DETAILS
PL502 PLUMBING DETAILS
PL503 PLUMBING DETAILS
PL504 PLUMBING DETAILS
PL601 PLUMBING SCHEDULES
PL701 PLUMBING RISER DIAGRAMS
PL702 PLUMBING RISER DIAGRAMS
PL703 PLUMBING RISER DIAGRAMS
PL704 PLUMBING RISER DIAGRAMS
PL705 PLUMBING RISER DIAGRAMS
A-410 ENLARGED PLANS & INTERIOR ELEVATIONS
A-411 ENLARGED PLANS & INTERIOR ELEVATIONS
A-412 ENLARGED PLANS & INTERIOR ELEVATIONS
A-420 ENLARGED PLANS & INTERIOR ELEVATIONS
A-421 ENLARGED PLANS & INTERIOR ELEVATIONS
A-422 INTERIOR ELEVATIONS
A-501 DETAILS I
A-502 DETAILS II
A-503 DETAILS III
A-504 DETAILS IV
A-505 DETAILS V
A-510 SECTION DETAILS
A-511 SECTION DETAILS
A-512 EXTERIOR DETAILS
A-520 EXTERIOR DETAILS
A-521 EXTERIOR DETAILS
A-522 EXTERIOR DETAILS
A-523 EXTERIOR DETAILS
A-530 STAIR DETAILS
A-531 COLUMN DETAIL SCHEDULE
A-532 COLUMN DETAILS
A-533 COLUMN DETAILS
A-534 COLUMN DETAILS
A-535 INTERIOR DETAILS
A-536 INTERIOR DETAILS
A-537 INTERIOR DETAILS
A-601 DOOR SCHEDULE AND DOOR & FRAME TYPES
A-602 DOOR SCHEDULE AND DOOR & FRAME TYPES
A-603 DOOR & WINDOW DETAILS
A-604 DOOR & WINDOW DETAILS
A-605 WINDOW DETAILS
A-606 WINDOW DETAILS
A-607 WINDOW & OPENING DETAILS
A-608 STOREFRONT & LOUVER DETAILS
A-611 FIRST FLOOR FINISH SCHEDULE
A-612 SECOND FLOOR FINISH SCHEDULE
A-701 LIFE SAFETY NOTES
A-702 LIFE SAFETY NOTES
A-710 FIRST FLOOR LIFE SAFETY PLAN
A-720 SECOND FLOOR LIFE SAFETY PLAN
A-801 FIRST FLOOR BUILDING AIR BARRIER PLAN
A-802 SECOND FLOOR AIR BARRIER PLAN
A-803 AIR BARRIER BOUNDARY SECTIONS
A-804 AIR BARRIER BOUNDARY SECTIONS
A-805 AIR BARRIER DETAILS
I-001 FURNITURE LEGEND
I-110 FURNITURE PLAN - FIRST FLOOR - COMPOSITE
I-111 FURNITURE PLAN - FIRST FLOOR - PART A
I-112 FURNITURE PLAN - FIRST FLOOR - PART B
I-113 FURNITURE PLAN - FIRST FLOOR - PART C
I-114 FURNITURE PLAN - FIRST FLOOR - PART D
I-115 FURNITURE PLAN - FIRST FLOOR - PART E
I-120 FURNITURE PLAN - SECOND FLOOR - COMPOSITE
I-121 FURNITURE PLAN - SECOND FLOOR - PART A
I-122 FURNITURE PLAN - SECOND FLOOR - PART B
I-123 FURNITURE PLAN - SECOND FLOOR - PART C
I-124 FURNITURE PLAN - SECOND FLOOR - PART D
I-125 FURNITURE PLAN - SECOND FLOOR - PART E
I-131 FINISH PLAN - FIRST FLOOR - PART A
I-132 FINISH PLAN - FIRST FLOOR - PART B
I-133 FINISH PLAN - FIRST FLOOR - PART C
I-134 FINISH PLAN - FIRST FLOOR - PART D
I-135 FINISH PLAN - FIRST FLOOR - PART E
I-141 FINISH PLAN - SECOND FLOOR - PART A
I-142 FINISH PLAN - SECOND FLOOR - PART B
I-143 FINISH PLAN - SECOND FLOOR - PART C
I-144 FINISH PLAN - SECOND FLOOR - PART D
I-145 FINISH PLAN - SECOND FLOOR - PART E
I-501 SIGNAGE SCHEDULE & DETAILS 1
I-502 SIGNAGE SCHEDULE & DETAILS 2
I-503 SIGNAGE SCHEDULE & DETAILS 3
I-504 SIGNAGE TYPICALS 1
I-505 SIGNAGE TYPICALS 2
I-506 SIGNAGE TYPICALS 3
I-507 SIGNAGE TYPICALS 4
I-601 FINISH LEGEND
I-602 ROOM FINISH SCHEDULE & DETAILS 1
I-603 ROOM FINISH SCHEDULE & DETAILS 2
I-604 ROOM FINISH SCHEDULE & DETAILS 3
I-605 ROOM FINISH SCHEDULE & DETAILS 4
I-606 ROOM FINISH SCHEDULE & DETAILS 5
FA001 FIRE ALARM LEGEND AND OPERATIONS MATRIX
G-001 COVER SHEET
GI001 INDEX OF DRAWINGS
GI002 INDEX OF DRAWINGS
GI003 ABBREVIATIONS & PROJECT INFORMATION
S-001 GENERAL STRUCTURAL NOTES
S-002 DESIGN DATA
SB101 FOUNDATION PLAN - COMPOSITE
SB102 FOUNDATION PLAN - PART A
SB103 FOUNDATION PLAN - PART B
SB104 FOUNDATION PLAN - PART C
SB105 FOUNDATION PLAN - PART D
SB106 FOUNDATION PLAN - PART E
SB501 FOUNDATION DETAILS
SB502 FOUNDATION DETAILS
SB503 FOUNDATION DETAILS
SB601 FOUNDATION SCHEDULES
SB602 FOUNDATION SCHEDULES
SF101 SECOND FLOOR FRAMING PLAN - COMPOSITE
SF102 SECOND FLOOR FRAMING PLAN - PART A
SF103 SECOND FLOOR FRAMING PLAN - PART B
SF104 SECOND FLOOR FRAMING PLAN - PART C
SF105 SECOND FLOOR FRAMING PLAN - PART D
SF106 SECOND FLOOR FRAMING PLAN - PART E
SF107 ROOF FRAMING PLAN - COMPOSITE
SF108 ROOF FRAMING PLAN - PART A
SF109 ROOF FRAMING PLAN - PART B
SF110 ROOF FRAMING PLAN - PART C
SF111 ROOF FRAMING PLAN - PART D
SF112 ROOF FRAMING PLAN - PART E
SF201 FRAME ELEVATIONS
SF202 FRAME ELEVATIONS
SF203 FRAME ELEVATIONS
SF204 FRAME ELEVATIONS
SF205 FRAME ELEVATIONS
SF206 FRAME ELEVATIONS
SF301 BUILDING SECTIONS
SF302 BUILDING SECTIONS
SF501 FRAMING SECTIONS
SF502 FRAMING DETAILS
SF503 FRAMING DETAILS
SF504 FRAMING DETAILS
SF505 FRAMING DETAILS
SF506 FRAMING DETAILS
SF507 FRAMING DETAILS
SF508 TRUSS PROFILES
SF509 TRUSS PROFILES
SF601 SCHEDULES
A-110 FIRST FLOOR PLAN - OVERALL
A-111 FIRST FLOOR PLAN - PART A
A-112 FIRST FLOOR PLAN - PART B
A-113 FIRST FLOOR PLAN - PART C
A-114 FIRST FLOOR PLAN - PART D
A-115 FIRST FLOOR PLAN - PART E
A-120 SECOND FLOOR PLAN - OVERALL
A-121 SECOND FLOOR PLAN - PART A
A-122 SECOND FLOOR PLAN - PART B
A-123 SECOND FLOOR PLAN - PART C
A-124 SECOND FLOOR PLAN - PART D
A-125 SECOND FLOOR PLAN - PART E
A-130 ROOF PLAN - OVERALL
A-140 FIRST FLOOR REFLECTED CEILING PLAN - OVERALL
A-141 FIRST FLOOR REFLECTED CEILING PLAN - PART A
A-142 FIRST FLOOR REFLECTED CEILING PLAN - PART B
A-143 FIRST FLOOR REFLECTED CEILING PLAN - PART C
A-144 FIRST FLOOR REFLECTED CEILING PLAN - PART D
A-145 FIRST FLOOR REFLECTED CEILING PLAN - PART E
A-150 SECOND FLOOR REFLECTED CEILING PLAN - OVERALL
A-151 SECOND FLOOR REFLECTED CEILING PLAN - PART A
A-152 SECOND FLOOR REFLECTED CEILING PLAN - PART B
A-153 SECOND FLOOR REFLECTED CEILING PLAN - PART C
A-154 SECOND FLOOR REFLECTED CEILING PLAN - PART D
A-155 SECOND FLOOR REFLECTED CEILING PLAN - PART E
A-201 EXTERIOR ELEVATIONS
A-202 ENLARGED NORTH ELEVATION
A-203 ENLARGED EAST & WEST ELEVATIONS
A-204 ENLARGED SOUTH ELEVATION
A-301 BUILDING SECTIONS
A-303 WALL SECTIONS
A-304 WALL SECTIONS
A-401 ELEVATOR PLANS & ELEVATIONS
A-403 INTERIOR ELEVATIONS
A-404 STAIR SECTIONS
SHEET ID. TITLE
INDEX OF DRAWINGS - VOLUME
SHEET ID. SHEET ID.TITLE TITLE
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
F:\Revit Local\FY16PN80773BOF_PROJECT_R15_K6ENDKRW.rvt
7/1/2016 6:50:45 AM
JU
LY
- W
2P M
-1 6-
R -0
D es ig ne r
Au th or
Ap pr ov er
1-
-2
GI002
IN
D
EX
O
F D
R A W
IN
G
S
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
6 9 D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
, N O
R
TH
C
AR
O
LI
N A
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SA
VA
N N
AH
D
IS
TR
IC
T
W
ES
T O
G
LE
TH
O
R
PE
A
VE
N U
E
SA
VA
N
N
AH
, G
EO
R G
IA
FO
R
T
BR
AG
G
, N O
R T H
C
AR
O
LI
N A
S O F
BA
T T
AL
IO
N O
PE
R
A T
IO
N S
F A C
IL
IT
Y P N
VO
L U M
E
O F
C he ck er
RTA SUBMITTAL
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
EP124 RECEPTACLE PLAN - 2ND FLOOR - PART D
EP125 RECEPTACLE PLAN - 2ND FLOOR - PART E
EP131 EQUIPMENT AND PANELBOARD PLAN - 1ST FLOOR - PART A
EP132 EQUIPMENT AND PANELBOARD PLAN - 1ST FLOOR - PART B
EP133 EQUIPMENT AND PANELBOARD PLAN - 1ST FLOOR - PART C
EP134 EQUIPMENT AND PANELBOARD PLAN - 1ST FLOOR - PART D
EP135 EQUIPMENT AND PANELBOARD PLAN - 1ST FLOOR - PART E
EP141 EQUIPMENT AND PANELBOARD PLAN - 2ND FLOOR - PART A
EP142 EQUIPMENT AND PANELBOARD PLAN - 2ND FLOOR - PART B
EP143 EQUIPMENT AND PANELBOARD PLAN - 2ND FLOOR- PART C
EP144 EQUIPMENT AND PANELBOARD PLAN - 2ND FLOOR - PART D
EP145 EQUIPMENT AND PANELBOARD PLAN - 2ND FLOOR - PART E
EP401 POWER PLAN - ENLARGED
EP601 POWER SINGLE LINE DIAGRAM
EP602 PANEL SCHEDULES
EP603 PANEL SCHEDULES
EP604 PANEL SCHEDULES
EP605 PANEL SCHEDULES
EP606 PANEL SCHEDULES
EP607 PANEL SCHEDULES
EP608 PANEL SCHEDULES
EP609 PANEL SCHEDULES
EP610 PANEL SCHEDULES
EP611 PANEL SCHEDULES
EP612 PANEL SCHEDULES
EP613 PANEL AND FEEDER AND TRANSFORMER SCHEDULES
EP614 MECHANICAL EQUIPMENT FEEDER SCHEDULE
ESS111 FIRST FLOOR SECURITY PLAN - PART A
ESS112 FIRST FLOOR SECURITY PLAN - PART B
ESS113 FIRST FLOOR SECURITY PLAN - PART C
ESS114 FIRST FLOOR SECURITY PLAN - PART D
ESS115 FIRST FLOOR SECURITY PLAN - PART E
ESS121 SECOND FLOOR SECURITY PLAN - PART A
ESS122 SECOND FLOOR SECURITY PLAN - PART B
ESS123 SECOND FLOOR SECURITY PLAN - PART C
ESS124 SECOND FLOOR SECURITY PLAN - PART D
ESS125 SECOND FLOOR SECURITY PLAN - PART E
ESS501 SECURITY DETAILS
ESS502 SECURITY DETAILS
ESS503 SECURITY DETAILS
ESS601 ACCESS CONTROL RISER
ESS602 VIDEO SURVEILANCE RISER
ESS701 SECURITY ELEVATIONS
T-001 COMMUNICATIONS LEGEND AND GENERAL NOTES
T-111 COMMUNICATIONS PLAN - 1ST FLOOR - PART A
T-112 COMMUNICATIONS PLAN - 1ST FLOOR - PART B
T-113 COMMUNICATIONS PLAN - 1ST FLOOR - PART C
T-114 COMMUNICATIONS PLAN - 1ST FLOOR - PART D
T-115 COMMUNICATIONS PLAN - 1ST FLOOR - PART E
T-121 COMMUNICATIONS PLAN - 2ND FLOOR - PART A
T-122 COMMUNICATIONS PLAN - 2ND FLOOR - PART B
T-123 COMMUNICATIONS PLAN - 2ND FLOOR - PART C
T-124 COMMUNICATIONS PLAN - 2ND FLOOR - PART D
T-125 COMMUNICATIONS PLAN - 2ND FLOOR - PART E
T-401 COMMUNICATIONS PLAN - ENLARGED
T-501 COMMUNICATIONS DETAILS
T-502 COMMUNICATIONS DETAILS
T-503 COMMUNICATIONS DETAILS
T-601 COMMUNICATIONS RISER DIAGRAMS
T-602 COMMUNICATIONS RISER DIAGRAMS
T-603 COMMUNICATIONS WALL ELEVATIONS
T-604 COMMUNICATIONS WALL ELEVATIONS
AV114 FIRST FLOOR AUDIO VISUAL PLAN - PART D
AV115 FIRST FLOOR AUDIO VISUAL PLAN - PART E
AV121 SECOND FLOOR AUDIO VISUAL PLAN - PART A
AV122 SECOND FLOOR AUDIO VISUAL PLAN - PART B
AV123 SECOND FLOOR AUDIO VISUAL PLAN - PART C
AV124 SECOND FLOOR AUDIO VISUAL PLAN - PART D
AV125 SECOND FLOOR AUDIO VISUAL PLAN - PART E
AV501 AUDIO VISUAL DETAILS
AV502 AUDIO VISUAL DETAILS
AV601 AUDIO VISUAL RISER DIAGRAM
AV602 AUDIO VISUAL RISER DIAGRAM
AV603 AUDIO VISUAL RISER DIAGRAM
AV604 AUDIO VISUAL RISER DIAGRAM
AV701 AUDIO VISUAL ELEVATIONS
AV702 AUDIO VISUAL ELEVATIONS
AV703 AUDIO VISUAL ELEVATIONS
AV704 AUDIO VISUAL ELEVATIONS
AV710 AUDIO VISUAL ELEVATIONS - RACKS
M-001 HVAC LEGEND
MH111 HVAC PLAN - 1ST FLOOR - PART A
MH112 HVAC PLAN - 1ST FLOOR - PART B
MH113 HVAC PLAN - 1ST FLOOR - PART C
MH114 HVAC PLAN - 1ST FLOOR - PART D
MH115 HVAC PLAN - 1ST FLOOR - PART E
MH121 HVAC PLAN - 2ND FLOOR - PART A
MH122 HVAC PLAN - 2ND FLOOR - PART B
MH123 HVAC PLAN - 2ND FLOOR - PART C
MH124 HVAC PLAN - 2ND FLOOR - PART D
MH125 HVAC PLAN - 2ND FLOOR - PART E
MH301 HVAC SECTIONS
MH302 HVAC SECTIONS
MH303 HVAC SECTIONS
MH401 ENLARGED HVAC PLAN MECH RM G153
MH402 ENLARGED PIPING PLAN MECH RM G153
MH403 ENLARGED HVAC PLAN MECH RM G248
MH404 ENLARGED PIPING PLAN MECH RM G248
MH501 HVAC DETAILS
MH502 HVAC DETAILS
MH503 HVAC DETAILS
MH504 HVAC DETAILS
MH505 HVAC DETAILS
MH601 HVAC SCHEDULES
MH602 HVAC SCHEDULES
MH603 HVAC SCHEDULES
MI001 HVAC CONTROLS LEGEND
MI002 HVAC CONTROLS GENERAL NOTES
MI003 HVAC CONTROLS GENERAL NOTES
MI801 AHU CONTROL SCHEMATIC
MI802 AHU SEQUENCE OF OPERATION
MI803 AHU POINTS SCHEDULE
MI804 DOAS CONTROL SCHEMATIC
MI805 DOAS SEQUENCE OF OPERATION
MI806 DOAS POINTS SCHEDULE
MI807 FAN COIL UNIT CONTROL SCHEMATIC, SEQUENCE, AND POINTS SCHEDULE
MI808 HYDRONIC CONTROL SCHEMATICS
MI809 HYDRONIC SEQUENCE OF OPERATION
MI810 HYDRONIC POINTS SCHEDULES
MI811 MISC CONTROLS SCHEMATICS AND SEQUENCES OF OPERATION
MI812 MISC CONTROLS POINTS
MI813 MISC CONTROL POINTS
MI814 DOMESTIC HOT WATER CONTROL SCHEMATIC, SEQUENCE, AND POINTS SCHEDULE
MP111 HVAC HYDRONIC PIPING PLAN - 1ST FLOOR - PART A
MP112 HVAC HYDRONIC PIPING PLAN - 1ST FLOOR - PART B
MP113 HVAC HYDRONIC PIPING PLAN - 1ST FLOOR - PART C
MP114 HVAC HYDRONIC PIPING PLAN - 1ST FLOOR - PART D
MP115 HVAC HYDRONIC PIPING PLAN - 1ST FLOOR - PART E
MP121 HVAC HYDRONIC PIPING PLAN - 2ND FLOOR - PART A
MP122 HVAC HYDRONIC PIPING PLAN - 2ND FLOOR - PART B
MP123 HVAC HYDRONIC PIPING PLAN - 2ND FLOOR - PART C
MP124 HVAC HYDRONIC PIPING PLAN - 2ND FLOOR - PART D
MP125 HVAC HYDRONIC PIPING PLAN - 2ND FLOOR - PART E
E-001 LEGEND AND NOTES
EG111 LIGHTNING PROTECTION PLAN - WEST
EG112 LIGHTNING PROTECTION PLAN - EAST
EG501 LIGHTNING PROTECTION DETAILS
EG502 LIGHTNING PROTECTION AND GROUNDING DETAILS
EL111 LIGHTING PLAN - 1ST FLOOR - PART A
EL112 LIGHTING PLAN - 1ST FLOOR - PART B
EL113 LIGHTING PLAN - 1ST FLOOR - PART C
EL114 LIGHTING PLAN - 1ST FLOOR - PART D
EL115 LIGHTING PLAN - 1ST FLOOR - PART E
EL121 LIGHTING PLAN - 2ND FLOOR - PART A
EL122 LIGHTING PLAN - 2ND FLOOR - PART B
EL123 LIGHTING PLAN - 2ND FLOOR - PART C
EL124 LIGHTING PLAN - 2ND FLOOR - PART D
EL125 LIGHTING PLAN - 2ND FLOOR - PART E
EL501 LIGHT FIXTURE SCHEDULE AND DETAILS
EL502 LIGHT FIXTURE DETAILS
EL503 LIGHT FIXTURE DETAILS
EL601 LIGHTING CONTROL STRATEGIES
EL602 LIGHTING CONTROL DETAILS
EL603 LIGHTING CONTROL DETAILS
EP111 RECEPTACLE PLAN - 1ST FLOOR - PART A
EP112 RECEPTACLE PLAN - 1ST FLOOR - PART B
EP113 RECEPTACLE PLAN - 1ST FLOOR - PART C
EP114 RECEPTACLE PLAN - 1ST FLOOR - PART D
EP115 RECEPTACLE PLAN - 1ST FLOOR - PART E
EP121 RECEPTACLE PLAN - 2ND FLOOR - PART A
EP122 RECEPTACLE PLAN - 2ND FLOOR - PART B
EP123 RECEPTACLE PLAN - 2ND FLOOR - PART C
SHEET LOGICMATERIALS
EARTH
DRAWING ABBREVIATIONS GENERAL NOTES
C (cont) ---------------------
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE, CONTINUOUS
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABEL CLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION
AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE
BOARD (INSULATION)
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED, EXPANSION
EXT EXTERIOR, EXTINGUISHER
EXT GR EXTERIOR GRADE
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR
PANEL
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER
CABINET
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED
GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED
PLASTIC
FRTW FIRE RETARDANT TREATED
WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GEJ GUTTER EXPANSION JOINT
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GFRG GLASS-FIBER-
REINFORCED GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GWB GYPSUM WALL BOARD
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H -------------
HB HOSE BIBB
HC HANDICAPPED
HDPE HIGH DENSITY
POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY
PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING
CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
JT JOINT
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LG LIGHT GAUGE
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTD MOUNTED
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE
WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE
PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION
COEFFICIENT
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PREFIN PREFINISHED
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE
FOOT
PSI POUNDS PER SQUARE
INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER
AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK
MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
R (cont) --------------------
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL SHEET METAL
FLASH (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS STAINLESS STEEL
SSMR STANDING SEAM METAL ROOF
ST STAIRS
STC SOUND TRANSMISSION
COEFFICIENT
STD STANDARD
STL STEEL
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
STRUC STRUCTURAL
SUB FL SUBFLOOR
SUSP SUSPENDED
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
TH THICK
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
TYP TYPICAL
U --------------------
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITER
LABORATORIES
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER
SYSTEM
V --------------------
VAV VARIABLE AIR VOLUME/UNIT
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VTR VENT THRU ROOF
W --------------------
W/ WITH
WC WATER CLOSET
WD WOOD
WDW WINDOW
W/O WITHOUT
WWF WELDED WIRE FABRIC
X --------------------
XFMR TRANSFORMER
A ---------------------
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABV ABOVE
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL
SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH
DISABILITIES ACT
ADJ ADJACENT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED
CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AWT ACOUSTICAL WALL
TREATMENT
B ---------------------
B LABEL CLASS B DOOR
BALC BALCONY
BD BOARD
BDRY BOUNDARY
BEJ BRICK EXPANSION JOINT
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE
MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C LABEL CLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER)
BOARD
CD CONSTRUCTION
DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CFCI CONTRACTOR
FURNISHED/CONTRACTOR
INSTALLED
CFE CONTRACTOR FURNISHED
EQUIPMENT
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL
FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
0 GRID/COLUMN
LINE
DESIGNATOR
INTERIOR ELEVATION
SECTION
ROOM
NAME/NUMBER
REVISION
TAG
PLAN, BLOW-UP DETAIL
PLAN NORTH
NORTH ARROW
w/ TRUE NORTH
INDICATION
SPOT ELEVATION
Name Elevation
REFERENCE LEVEL
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
A-101
SIM
A-101
Ref
R ef
R ef
Ref
A101
Ref
R ef
Ref
R ef
EXTERIOR ELEVATION
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
A-101
SYMBOLS
INTERIOR ELEVATION SYMBOL
EXTERIOR ELEVATION SYMBOL
SECTION SYMBOL
CALLOUT SYMBOL
ELEVATION SYMBOL
LEVEL SYMBOL
GENERAL SYMBOLS
Room name
Room name
150 SF
ROOM
NAME/NUMBE
R W/ AREA
CENTERLINE
INDICATOR
1/2 1 21
SCALE: 1"=1'-0"
SCALE BAR
1 View Name 1/8" = 1'-0"R101
MATCHLINE INDICATOR
VIEW TITLE BAR
1 / A-101
1 / A-102
REFERENCE SHEETS
SAND
CONCRETE/ PRECAST
CONCRETE
STONE
BRICK
CMU
PLYWOOD
RIGID INSULATION
FIBERGLASS BATT
INSULATION
GYPSUM BOARD,
PLASTER
EIFS
1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO THE CONDITIONS
ON THIS SET OF DRAWINGS TO THE EXTENT APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR ABBREVIATIONS MAY APPEAR IN THIS SET OF DRAWINGS TO INDICATE
SPECIFIC CONDITIONS IN LIEU OF SYMBOLS SHOWN ON THIS SHEET.
AE201
DISCIPLINE*:
G - GENERAL
C - CIVIL
L - LANDSCAPE
S - STRUCTURAL
A - ARCHITECTURE
DISCIPLINE
DESIGNATOR
SHEET TYPE
DESIGNATOR
SHEET SEQUENCE
NUMBER (FLOOR*
FOR PLAN VIEWS)
SHEET SEQUENCE
NUMBER (KEY PLAN*
FOR PLAN VIEWS)
F- FIRE PROTECTION
P - PLUMBING
M - MECHANICAL
E - ELECTRICAL
T- TELECOMMUNICATIONS
*ADDITIONAL DISCIPLINES MAY BE USED IN
THIS DRAWING SET.
DRAWING NAMING CONVENTION
SHEET ID
KEY PLAN
PART A PART B PART C PART D
PART E
FLOORS:
0- UNDERSLAB
1- FIRST FLOOR
2- SECOND FLOOR
3-9- ADD'L PLANS AND/OR LEVELS AS NEEDED*
*SOME DISCIPLINES CONTAIN MULTIPLE PLAN
TYPES (e.g. PL111-115/PL121-125 IS DOMESTIC
PLUMBING AND PL131-135/PL141-145 IS
SANITARY PLUMBING)
KEY PLAN:
0- OVERALL (IF APPLICABLE)
1- PART A
2- PART B
3- PART C
4- PART D
5- PART E
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
F:\Revit Local\FY16PN80773BOF_PROJECT_R15_K6ENDKRW.rvt
7/1/2016 6:50:57 AM
JU
LY
- W
2P M
-1 6-
R -0
1-
-2
GI003
AB
BR
EV
IA
TI
O
N S
PR
O J E
C T
IN
FO
R M
AT
IO
N
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
6 9 D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
, N O
R
TH
C
AR
O
LI
N A
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SA
VA
N N
AH
D
IS
TR
IC
T
W
ES
T O
G
LE
TH
O
R
PE
A
VE
N U
E
SA
VA
N
N
AH
, G
EO
R G
IA
FO
R
T
BR
AG
G
, N O
R T H
C
AR
O
LI
N A
S O F
BA
T T
AL
IO
N O
PE
R
A T
IO
N S
F A C
IL
IT
Y P N
VO
L U M
E
O F
RTA SUBMITTAL
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
GENERAL NOTES:
G-1. USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH ALL OTHER DRAWINGS. COORDINATE THE WORK OF OTHER TRADES INCLUDING, BUT NOT LIMITED TO, THE REQUIREMENTS FOR SLEEVES, INSERTS, HOLES, HANGERS, AND ANCHORS.
G-2. REPORT DISCREPANCIES IN DIMENSIONS BETWEEN DIFFERENT DRAWINGS TO CONTRACTING
OFFICER PRIOR TO BEGINNING WORK IN AREAS THAT WILL BE AFFECTED.
G-3. DETAILS TITLED OR NOTED AS "TYPICAL" APPLY NOT ONLY WHERE SPECIFICALLY INDICATED OR
REFERENCED, BUT ALSO IN ALL OTHER CASES WHERE THE NATURE OF THE CONSTRUCTION
REQUIRES THEIR USE. DETERMINE APPLICABILITY OF TYPICAL DETAILS FROM DESCRIPTIVE TITLES OR FROM THE SIMILARITY OF A CONSTRUCTION CONDITION TO ANOTHER CONDITION WHERE THE
DETAIL IS SPECIFICALLY INDICATED OR REFERENCED.
G-4. PROVIDE TEMPORARY BRACING AND SHORING OF THE STRUCTURE AND COMPONENTS UNTIL ALL COMPONENTS ARE ERECTED AND ALL CONNECTIONS ARE FULLY MADE, AS NECESSARY, TO ENSURE
STABILITY DURING CONSTRUCTION. BRACE ALL WALLS DURING CONSTRUCTION AGAINST WIND
AND/OR CONSTRUCTION LOADS.
G-5. ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS [±X'-X"] REFERENCED TO THE FINISHED FIRST FLOOR ELEVATION DATUM [0'-0"]. SEE CIVIL DRAWINGS FOR ACTUAL DATUM
ELEVATION.
G-6. REPRODUCTION OF CONTRACT DRAWINGS SHALL NOT BE USED AS SHOP DRAWINGS UNDER ANY
CIRCUMSTANCE.
FOUNDATION AND SLAB NOTES:
F-1. FOUNDATIONS FOR THIS PROJECT HAVE BEEN DESIGNED IN ACCORDANCE WITH THE
RECOMMENDATIONS IN THE GEOTECHNICAL REPORT PREPARED BY THE SAVANNAH DISTRICT TITLED "SUBSURFACE EXPLORATION AND GEOTECHNICAL ENGINEERING REPORT, BATTALION OPERATIONS
FACILITY, FY 16, LI 80773,FT BRAGG, NC", DATED JANUARY 2016.
F-2. FOUNDATIONS HAVE BEEN DESIGNED TO BEAR ON SOIL CAPABLE OF SUPPORTING AN ALLOWABLE BEARING PRESSURE OF 2000 PSF AS STATED IN THE GEOTECHNICAL REPORT REFERENCED ABOVE.
F-3. THE CONTRACTOR SHALL HIRE AN INDEPENDENT TESTING LABORATORY AND GEOTECHNICAL ENGINEER, REGISTERED AND LICENSED IN THE STATE WHERETHE WORK WILL BE ACCOMPLISHED, TO VERIFY THAT ALL OF THE REQUIREMENTS CONTAINED IN SPECIFICATION 31 00 00, EARTHWORK, HAVE BEEN FOLLOWED AND ACCOMPLISHED.
F-4. ALL EXCAVATIONS SHALL BE PERFORMED SO THAT THE SITE AND THE AREA IMMEDIATELY SURROUNDING THE SITE WHICH AFFECTS CONSTRUCTION OPERATIONS WILL BE CONTINUALLY AND
EFFECTIVELY DRAINED. THE CONTRACTOR SHALL PROVIDE DRAINAGE AND DEWATERING AS
REQUIRED TO ENSURE THAT ALL FOOTING EXCAVATIONS ARE ACCOMPLISHED WITH THE SUBGRADE SOILS REMAINING DRY AND FIRM UNTIL AFTER FOOTINGS ARE PLACED AND BACKFILLED. REMOVAL
OF SURFACE WATER, GROUNDWATER, AND ANY PERCHED WATER CONDITIONS WHICH MIGHT BE
ENCOUNTERED DURING EXCAVATIONS, SHALL BE ACCOMPLISHED BY APPROVED MEANS. REFER TO SPECIFICATION SECTION 31 00 00, EARTHWORK, AND TO SHEET B-301 FOR ADDITIONAL EXCAVATION
REQUIREMENTS.
F-5. DO NOT PLACE FOUNDATION CONCRETE ON FROZEN OR SATURATED SUBGRADES.
F-6. ENSURE THAT EARTH-FORMED FOOTINGS CONFORM TO THE SHAPE, LINES, AND THICKNESSES INDICATED ON THE FOUNDATION PLAN, SECTIONS, AND FOOTING SCHEDULES. EXCAVATION WIDTHS
SHALL BE A MINIMUM OF 4" GREATER THAN DIMENSIONS INDICATED.
F-7. DO NOT INSTALL FOUNDATIONS UNTIL FOUNDATION WORK HAS BEEN COORDINATED WITH
ADJACENT UNDERGROUND UTILITIES.
F-8. FOOTINGS SHALL BE LOWERED AS REQUIRED TO PASS UNDER UTILITY LINES. STEP CONTINUOUS FOOTINGS DOWN AS SHOWN IN THE "TYPICAL STEPPEDFOOTING DETAIL" ON SHEET SB502. IN LIEU
OF STEPPED FOOTINGS, PIPE SLEEVES THROUGH FOOTINGS MAY BE PROVIDED AS NECESSARY
ACCORDING TO TYPICAL DETAILS.
F-9. PLACE 10 MIL VAPOR RETARDER AND 4" CAPILLARY WATER BARRIER UNDER ALL INTERIOR SLABS-
ON-GRADE (TYPICAL).
CONCRETE CONSTRUCTION NOTES:
C-1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF THE "BUILDING CODE REQUIREMENTS FOR REINFORCEDCONCRETE" (ACI 318-11) AND THE SPECIFICATIONS FOR
STRUCTURAL CONCRETE (ACI 301-11) OF THE AMERICAN CONCRETE INSTITUTE (ACI).
C-2. ALL CAST-IN-PLACE CONCRETE SHALL ATTAIN MINIMUM 28-DAY COMPRESSIVE STRENGTH (f'c)
OF 4000 PSI.
C-3. CONCRETE DENSITY SHALL BE NORMAL WEIGHT WITH A DENSITY OF 140 PCF TO 150 PCF UNLESS
NOTED OTHERWISE ON PLANS. CONCRETE NOTED TO BE LIGHTWEIGHT SHALL HAVE DENSITY OF
105 PCF TO 115 PCF.
C-4. CONCRETE REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615/A615M, GRADE 60 AND SHALL HAVE FABRICATION TOLERANCES IN ACCORDANCE WITH ACI 315. SHOP
FABRICATE REINFORCING BARS WHICH ARE INDICATED TO BE BENT OR HOOKED.
C-5. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 OR ASTM A497. PROVIDE SHEET-TYPE WELDED
WIRE FABRIC. SHEET LAPS SHALL BE TIED AND LAPPED ONE FULL MESH SPACING PLUS 2".
C-6. CONCRETE REINFORCING STEEL SHALL BE CONTINUOUS UNLESS OTHERWISE INDICATED.
CONTINUOUS REINFORCING STEEL SHALL BE SPLICED AS SHOWN INSCHEDULE ON S-601 UNO ON PLANS. REINFORCING STEEL SHALL BE PLACED SO THAT SPACING IS GREATER THAN OR EQUAL TO 2X
BAR DIAMETER.
C-7. MINIMUM CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS INDICATED. IN NO CASE SHALL
REINFORCEMENT COVER BE LESS THAN THE REQUIREMENTS OF ACI 301.
A. CONCRETE DEPOSITED AGAINST THE GROUND 3"
B. CONCRETE EXPOSED TO EARTH OR WEATHER 2"
C. SLABS AND WALLS 1"
C-8. CONCRETE REINFORCING STEEL MARKED STANDARD HOOK SHALL HAVE A 90° HOOK A MINIMUM OF 12 BAR DIAMETERS IN LENGTH, UNLESS OTHERWISE NOTED. STIRRUPS, TIES, AND 180° HOOKS SHALL
CONFORM TO THE REQUIREMENTS OF ACI 318.
C-9. PROVIDE 1/2" THICK PRE-MOLDED JOINT FILLER MATERIAL WHERE SLABS ON GRADE ABUT VERTICAL
SURFACES.
C-10. ALL EMBEDDED ITEMS SHALL BE PROPERLY PLACED, ACCURATELY POSITIONED AND MAINTAINED
SECURELY IN PLACE PRIOR TO AND DURING CONCRETE PLACEMENT.
C-11. REINFORCING STEEL SHALL BE SPREAD AT SLEEVES, ANCHORS, RECESSES AND OTHER EMBEDDED
ITEMS UNLESS OTHERWISE INDICATED. REINFORCEMENT SHALL NOT BE CUT TO FACILITATE
PLACEMENT OF EMBEDDED ITEMS, UNLESS INDICATED.
C-12. NO CONCRETE SHALL BE PLACED UNTIL THE OWNER OR THE CONTRACTING OFFICER'S DESIGNATED
REPRESENTATIVE HAS INSPECTED ALL EMBEDDED WORK, INCLUDING REINFORCEMENT.
C-13. ALL EXPOSED CONCRETE EDGES SHALL BE CHAMFERED 3/4" OR AS INDICATED.
C-14. ALUMINUM SHALL NOT BE PLACED IN DIRECT CONTACT WITH CONCRETE UNLESS EFFECTIVELY
COATED OR COVERED TO PREVENT ALUMINUM-CONCRETE REACTION AND ELECTROLYTIC ACTION
BETWEEN ALUMINUM AND STEEL.
C-15. CONCRETE SLAB ON GRADE JOINTS INDICATED ARE DIAGRAMMATIC AND DO NOT REPRESENT ALL OF THE JOINTS REQUIRED FOR SLAB-ON-GRADE CONSTRUCTION. SLAB PANELS BETWEEN JOINTS SHALL BE SQUARE OR NEARLY SO AND SHALL NOT EXCEED AN ASPECT RATIO WITH PANEL LENGTH GREATER
THAN 1.5 TIMES THE PANEL WIDTH.
C-16. CONTRACTOR SHALL PROVIDE JOINTS AT ALL RE-ENTRANT CORNERS INCLUDING, BUT NOT LIMITED
TO, COLUMNS AND SLAB RECESSES.
C-17. IN ADDITION, CONTRACTOR SHALL COORDINATE SLAB ON GRADE JOINT REQUIREMENTS WITH SLAB-
ON-GRADE CONSTRUCTION SEQUENCING. CONTRACTOR SHALL SHOW JOINT LAYOUT ON
REINFORCING SHOP DRAWING SUBMITTAL FOR APPROVAL.
STEEL CONSTRUCTION NOTES:
S-1. FABRICATION AND ERECTION OF STRUCTURAL STEEL AND DESIGN OF CONNECTIONS SHALL BE IN ACCORDANCE WITH AISC 360-10, "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" DATED JUNE 22, 2010 AND AISC 303-10, "CODE OF STANDARD PRACTICE FOR BUILDING AND BRIDGES" DATED
APRIL 14, 2010. THE STRUCTURAL STEEL MEMBERS SHOWN IN THESE DRAWINGS HAVE BEEN
ANALYZED AND DESIGNED USING AISC 360-10, LRFD METHOD.
S-2. UNLESS OTHERWISE NOTED, STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE ABOVE-LISTED
AISC SPECIFICATION AND THE FOLLOWING:
A. WIDE FLANGE SHAPES (50 KSI) ASTM A992, GRADE B
B. HSS HOLLOW SHAPES (46 KSI) ASTM A500, GRADE B
B. PLATES AND ANGLES ASTM A36
C. HIGH STRENGTH BOLTS ASTM A325
D. ANCHOR RODS W/ NUT AND WASHER ASTM F1554, GRADE 36
S-3. IT IS THE INTENTION OF THESE DESIGN DOCUMENTS TO DELEGATE THE DESIGN OF ALL STRUCTURAL STEEL CONNECTIONS TO A QUALIFIED REGISTERED ENGINEER. SIGNED AND SEALED CALCULATIONS
FOR CONNECTION DESIGNS SHALL BE SUBMITTED FOR SIMULTANEOUSLY WITH FABRICATION
DRAWINGS FOR REVIEW. UNLESS NOTED OTHERWISE ON PLANS, ALL SHEAR CONNECTIONS FOR
SIMPLY SUPPORTED BEAMS SHALL BE DESIGNED TO DEVELOP THE REACTION OF THE MAXIMUM
ALLOWABLE UNIFORM LOAD CAPACITY FOR THE BEAM SIZE AND SPAN SHOWN, ASSUMING FULL
LATERAL SUPPORT, AS TABULATED IN THE ALLOWABLE UNIFORM LOAD TABLES OF THE AISC MANUAL, 14TH EDITION.
S-4. "STEEL ORDINARY MOMENT FRAMES" ARE USED IN THE LATERAL FORCE RESISTING SYSTEM. THE
MOMENT CONNECTIONS FOR THE FRAMING MEMBERS SHALL BE DESIGNED BY THE FABRICATOR
BASED ON THE MOMENTS AND LOADS SHOWN ON THE DRAWINGS. THE CONNECTION DETAILS FOR
THE MOMENT FRAMES ARE FOR ILLUSTRATION ONLY. THE FABRICATOR MAY MODIFY THE
CONNECTIONS AS NEEDED CONTINGENT THAT THEY MEET THE CRITERIA SET IN THE CURRENT AISC
CODE FOR SEISMIC CONNECTIONS.
S-5. ALL SHEAR CONNECTIONS BETWEEN WIDE FLANGE BEAMS AND HSS HOLLOW COLUMNS SHALL UTILIZE WT SECTIONS OFFSET SUCH THAT THE CENTERLINE OF THE BEAM AND CENTERLINE OF THE
COLUMN ALIGN.
S-6. ALL SHOP AND FIELD WELDING SHALL BE BY CERTIFIED WELDERS AND SHALL CONFORM TO AWS
STANDARDS. USE E70XX ELECTRODES UNLESS OTHERWISE NOTED. MINIMUM WELD SIZE FOR
STRUCTURAL STEEL IS 3/16 IN FILLET, UNLESS OTHERWISE NOTED. CURRENT AWS CERTIFICATIONS
SHALL BE AVAILABLE AT THE JOB SITE FOR REVIEW BY THE OWNERS' REPRESENTATIVE.
S-7. ALL BOLTED CONNECTIONS, UNLESS OTHERWISE NOTED, SHALL USE 3/4" DIAMETER HIGH STRENGTH
BOLTS WITH HARDENED CARBON STEEL WASHERS AS REQUIRED FOR THE CONNECTION LOADS.
BEAM CONNECTIONS SHALL CONSIST OF ALL-BOLTED DOUBLE-ANGLE CONNECTIONS UNLESS NOTED
OTHERWISE.
S-8. FIELD CUTTING OF STRUCTURAL STEEL MEMBERS BY ANY TRADE IS NOT PERMITTED. BOLT HOLES
SHALL NOT BE CUT OR ENLARGED BY FLAME CUTTING IN THE FIELD.
S-9. ALL FIELD-BOLTED SHEAR CONNECTIONS SHALL BE SNUG TIGHT BEARING-TYPE CONNECTIONS, THREADS INCLUDED IN THE SHEAR PLANE.
S-10. THE CONTRACTOR SHALL SUBMIT FOR APPROVAL DRAWINGS AND DESIGN CALCULATIONS FOR ANY
ALTERNATE DETAILS AND MEMBER SPLICES.
S-11. SHOP OR FIELD SPLICES OF STRUCTURAL STEEL MEMBERS ARE PROHIBITED EXCEPT AS DETAILED ON THE DRAWINGS, PERMITTED IN THE SPECIFICATIONS, AS INDICATED ON APPROVED SUBMITTALS, AND
AS SPECIFICALLY APPROVED ON SHOP DRAWINGS PRIOR TO FABRICATION.
S-12. PAINT ALL STEEL BELOW GRADE WITH BITUMINOUS COATING.
S-13. ALL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIPPED GALVANIZED IN ACCORDANCE WITH ASTM A123 FOR MEMBERS AND ASTM A153 FOR CONNECTION ELEMENTS, EXCEPT THAT ARCHITECTURALLY EXPOSED STRUCTURAL STEEL SHALL BE BLAST CLEANED AND COATED IN ACCORDANCE WITH THE
STRUCTURAL STEEL AND PAINT SPECIFICATIONS. COORDINATE ALL STEEL FINISHES WITH
ARCHITECTURAL DRAWINGS AND SPECIFICATIONS
S-14. REFER TO SPECIFICATION 05 12 00 FOR ADDITIONAL INFORMATION.
LIGHT GAUGE STEEL NOTES:
LG-1. ROOF LAYOUT AND COMPONENTS SHOWN ON THE DRAWINGS ARE FOR GENERAL CONFIGURATION ONLY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DIMENSIONS, ELEVATIONS, CONNECTION DETAILS, QUANTITIES, ETC. NECESSARY FOR THE COMPLETE DESIGN, FABRICATION, AND ERECTION
OF THE METAL FRAMING SYSTEM. THE CONTRACTOR SHALL COORDINATE THE DESIGN WITH THE
ARCHITECTURAL PLANS, ELEVATIONS, AND DETAILS. TRUSS DESIGN SHALL BE COORDINATED WITH
THE MECHANICAL CONTRACTOR AND WEB MEMBERS SHALL BE COORDINATED TO ACCOMODATE
EQUIPMENT, DUCTS, AND PIPES, AS REQUIRED. COORDINATE MEP LAYOUTS WITH EQUIPMENT
SUPPLIERS.
LG-2. LIGHT GAUGE FRAMING MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH THE AMERICAN IRON AND STEEL INSTITUTE (AISI) SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL
MEMBERS.
LG-3. ALL CALCULATIONS AND DRAWINGS USED IN THIS DESIGN MUST BE SIGNED AND STAMPED BY A PROFESSIONAL ENGINEER AND SUBMITTED FOR APPROVAL. IN ADDITION TO THE CALCULATIONS, THE SUBMITTAL SHALL INCLUDE DETAILS OF THE CONNECTIONS, ERECTION PLAN, LAYOUT, OUTRIGGERS, HEADERS, BRIDGING, AND BOTH TEMPORARY AND PERMANENT BRACING.
LG-4. THE CONTRACTOR SHALL SUBMIT COMPLETE PRODUCT CATALOGS FROM THE MATERIAL
MANUFACTURER FOR REVIEW PRIOR TO FABRICATION. THE CATALOGS SHALL INDICATE
QUALIFICATION, MATERIAL SPECIFICATIONS, DESIGN REFERENCES, ETC.
LG-5. ALL COLD-FORMED STEEL MEMBERS, THEIR COMPONENTS, AND CONNECTION MATERIAL SHALL BE
GALVANIZED. PREPARE AND REPAIR DAMAGED GALVANIZED COATINGS ON FABRICATED AND
INSTALLED LIGHT GAUGE METAL FRAMING WITH GALVANIZING REPAIR PAINT ACCORDING TO ASTM
A780 AND/OR THE MANUFACTURER'S RECOMMENDATIONS.
LG-6. COLD-FORMED STEEL MEMBERS SHALL BE Fy=33KSI FOR MEMBERS 43 MILS (18 GA) AND Fy=50KSI FOR MEMBERS 54 MILS (16 GA) AND HEAVIER. USE MIN 6" WIDE STUDS AT TRUSSES AND EXTERIOR WALLS
UNO.
LG-7. ALL WELDING OF LIGHT GAUGE STEEL SHALL COMPLY WITH AWS D1.1 AND AWS D1.3 FOR WELDING
BASE MATERIAL LESS THAN 1/8" THICK.
LG-8. FALL PROTECTION ANCHORS SHALL BE INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS. FALL
PROTECTION ANCHORS SHALL BE LOCATED PER THE MANUFACTURER'S RECOMMENDATIONS.
LOCATION OF FALL PROTECTION ANCHORS ON THE PLAN SHEETS ARE ILLUSTRATIVE ONLY. FALL
PROTECTION ANCHOR DESIGN LOAD IS 5000 LB (WORKING).
LG-9. TRUSS DEFLECTION LIMITS SHALL BE IN ACCORDANCE WITH IBC 2012; EXCEPT THAT MAXIMUM
DEFLECTION SHALL BE 1" FOR TRUSSES SUPPORTING OPERABLE PARTITION WALL.
LG-10. BRIDGING AND BRACING OF TRUSS COMPRESSION MEMBERS SHALL BE INSTALLED IN ACCORDANCE
WITH THE TRUSS MANUFACTURERS DESIGN AND DIRECTIONS. TRUSSES SHALL BE BRACED
SECURELY BOTH DURING ERECTION AND AFTER PERMANENT INSTALLATION BY THE CONTRACTOR.
ERECTION BRACING SHALL HOLD TRUSSES STRAIGHT AND PLUMB UNTIL DECKING AND PERMANENT TRUSS BRACING HAVE BEEN INSTALLED. ALL BRACING SHALL BE INSTALLED PRIOR TO THE LOADING OF THE TRUSSES. THE BOTTOM CHORD SHALL NOT BE ASSUMED TO BE LATERALLY SUPPORTED BY
THE CEILING CONSTRUCTION.
STEEL DECK NOTES:
SD-1. ROOF DECK SHALL BE GALVANIZED STEEL CONFORMING TO ASTM A653 WITH A MINIMUM YIELD
STRENGTH OF 33 KSI. STEEL ROOF DECK SHALL BE AS SHOWN ON DRAWINGS. FASTENERS FOR
ROOF DECK SHALL UTILIZE A MINIMUM OF #12 SELF TAPPING SCREWS AT A 36/7 PATTERN TO
SUPPORT STRUCTURE AND A MINIMUM OF (10) #10 SELF TAPPING SCREWS AT SIDE LAP
CONNECTIONS.
SD-2. COMPOSITE FLOOR DECK FOR SHALL BE GALVANIZED STEEL CONFORMING TO ASTM 653 WITH A MINIMUM YIELD STRENGTH OF 33 KSI. COMPOSITE STEEL FLOOR DECK SHALL BE AS SHOWN ON DRAWINGS. COMPOSITE FLOOR DECK SHALL BE FASTENED TO THE SUPPORTING STRUCTURE WITH 5/8" DIAMETER PUDDLE WELDS AT A 36/4 PATTERN AND WELDED SIDELAPS AT A MINIMUM OF 6 LOCATIONS. FASTEN DISCONTINUOUS SIDE OF FORM DECK TO SUPPORTING STRUCTURE WITH 5/8"
DIAMETER PUDDLE WELDS UNLESS OTHERWISE NOTED.
SD-3. PROVIDE ALL RIDGE PLATES, VALLEY PLATES, CLOSURE PLATES, POUR STOPS, AND ALL OTHER
ACCESSORIES REQUIRED FOR COMPLETE INSTALLATION IN ACCORDANCE WITH THE DECK
MANUFACTURER'S RECOMMENDATIONS.
SD-4. CONTRACTOR SHALL COORDINATE OPENINGS IN STEEL DECK WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS PRIOR TO DECK PLACEMENT.
SD-5. HANGING LOADS DIRECTLY FROM ROOF DECK IS PROHIBITED.
SD-6. STEEL DECK SHALL SPAN CONTINUOUSLY OVER A MINIMUM OF 4 SUPPORTS (3 SPANS) UNO.
SHEAR STUD CONNECTOR NOTES:
SS-1. SHEAR STUD CONNECTORS SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH AWS D1.1
"STRUCTURAL WELDING CODE", SECTION 7 - STUD WELDING.
SS-2. ATTACHMENT OF STUDS SHALL BE SUFFICIENT TO DEVELOP THE FULL CAPACITY OF EACH INDIVIDUAL
STUD.
SS-3. STUDS SHALL BE TYPE 'B', HEADED STUDS HAVING A MINIMUM TENSILE STRENGTH OF 65,000 PSI AND
SHALL BE OF LENGTH AND DIAMETER SHOWN ON STRUCTURAL DRAWINGS.
SS-4. FABRICATOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW AND APPROVAL WHICH INDICATES THE
SIZE, LENGTH, AND LOCATION OF SHEAR CONNECTOR STUDS.
STEEL JOIST NOTES:
SJ-1. DESIGN, FABRICATION AND ERECTION OF JOISTS, JOIST EXTENSIONS AND JOIST SUBSTITUTES SHALL
BE IN ACCORDANCE WITH SJI SPECIFICATIONS.
SJ-2. JOISTS, JOIST EXTENSIONS AND JOIST SUBSTITUTES SHALL BE DESIGNED TO THE SIZE, SPACING AND SLOPES INDICATED ON THE STRUCTURAL DRAWINGS. JOIST SIZES SHOWN ON PLANS ARE MINIMUM SIZES BASED ON SJI STANDARD UNIFORM GRAVITY LOAD TABLES. THE JOIST MANUFACTURER MAY INCREASE THE SIZE OF THE JOISTS, WITHIN THE SAME DEPTH CLASS, AS REQUIRED TO ACCOUNT FOR
UPLIFT LOADS OR OTHER NON-STANDARD LOADS.
SJ-3. ALL JOISTS, JOIST EXTENSIONS AND JOIST SUBSTITUTES SHALL BE DESIGNED BY THE STEEL JOIST
MANUFACTURER FOR THE DESIGN LOADS NOTED ON THE DRAWINGS INCLUDING:
1. ROOF DEAD LOAD OF 15 PSF
2. CONCENTRATED DEAD LOAD OF 500 LB PLACED AT TOP CHORD OF ANY PANEL POINT
ALONG THE LENGTH OF THE JOIST.
3. ROOF LIVE LOAD OF 20 PSF WITH LIVE LOAD DEFLECTION LESS THAN L/360
4. NET UPLIFT PRESSURES, GROSS UPLIFT PRESSURES INDICATED ON S-002.
5. POSITIVE WIND PRESSURES INDICATED ON S-002.
6. MECHANICAL AND ELECTRICAL EQUIPMENT, COORDINATE WITH MECHANICAL AND
ELECTRICAL DRAWINGS.
SJ-4. WHERE ROOF JOISTS ARE USED TO BRACE STEEL ROOF BEAMS (AS SHOWN IN DETAILS), DESIGN
JOISTS TO RESIST A 500 LB AXIAL BRACE LOAD AT EACH BRACE. THIS LOAD SHALL ACT
CONCURRENTLY WITH ALL WIND LOAD CASES AND COMBINATIONS.
SJ-5. WHERE JOIST SPANS EXCEED 30'-0", THE 3 JOISTS CLOSEST TO THE PERIMETER OF THE BUILDING
SHALL BE DESIGNED TO LIMIT LIVE LOAD DEFLECTION TO 1".
SJ-6. HANGERS FOR SUPPORT OF EQUIPMENT OR MEMBER SUPPORTING SUCH HANGERS, SHALL BE LOCATED AT PANEL POINTS OF JOISTS, AND SHALL BE HUNG FROM THE TOP CHORD OF JOISTS.
SJ-7. JOIST DESIGN SHALL INCLUDE ALL REQUIRED JOIST BRIDGING. BRIDGING SHALL BE SIZED, SPACED, AND INSTALLED IN ACCORDANCE WITH SJI SPECIFICATIONS.
SJ-8. JOISTS SHALL BE CONNECTED TO THE SUPPORTING STEEL IN ACCORDANCE WITH SJI
SPECIFICATIONS AND PROJECT CRITERIA NOTED ON DRAWINGS.
SJ-9. PROVIDE TOP AND BOTTOM CHORD EXTENSIONS WHERE NOTED ON DRAWINGS.
SJ-10. CALCULATIONS AND DRAWINGS PREPARED AND SIGNED BY A REGISTERED ENGINEER SHALL BE
SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW PRIOR TO FABRICATION OF JOISTS.
STRUCTURAL ABBREVIATIONS
SYMBOL DESCRIPTION
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
BOC BOTTOM OF CONCRETE
BOF BOTTOM OF FOOTING
BOM BOTTOM OF MASONRY
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
CJ CONSTRUCTION JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONN CONNECTION
CONC CONCRETE
CONT. CONTINUOUS
CONSTR CONSTRUCTION
DCJ DOWELED CONSTRUCTION JOINT
DEG DEGREE
DIA DIAMETER
DN DOWN
DWG(S) DRAWING(S)
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
EOS EDGE OF SLAB
EQ EQUAL
ERV ENERGY RECOVERY VENTILATOR
E.W. EACH WAY
FF FINISHED FLOOR
FTG FOOTING
GA GAGE
GALV GALVANIZED
GFGI GOVT
HORIZ HORIZONTAL
KIP (k) 1000 POUNDS
LG LONG
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
MAX MAXIMUM
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL, PLUMBING
MFR MANUFACTURER
MIN MINIMUM
NTS NOT TO SCALE
O.C. ON CENTER
OPP OPPOSITE
PEMB PRE-ENGINEERED METAL BUILDING
PJF PREMOLDED JOINT FILLER
PL PLATE
PLF POUNDS PER LINEAR FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
REINF REINFORCEMENT
REQD REQUIRED
SCHED SCHEDULE
SJ SAWED CONTRACTION JOINT
SJI STEEL JOIST INSTITUTE
SIM SIMILAR
SL SLOPE(D)
SOG SLAB ON GRADE
STD STANDARD
T&B TOP AND BOTTOM
TO TOP OF
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOS TOP OF SLAB
TS THICKENED SLAB
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VEF VEHICLE EXHAUST FAN
VERT VERTICAL
WP WORKING POINT
WWF WELDED WIRE FABRIC
SUPPORT FASTENERS
LAP FASTENERS
METAL DECK
METAL DECK
GAUGE
MOMENT OF INERTIA OF
STEEL SECTION, Ip (IN4)
SECTION MODULUS OF
STEEL SECTION
POSITIVE BENDING, Sp (IN3)
(ROOF DECK) - 1.5B18 (FLOOR DECK) - 1.5VL20
MINIMUM PROPERTIES OF METAL DECK
MOMENT OF INERTIA OF
STEEL SECTION, In (IN4)
SECTION MODULUS OF
STEEL SECTION
POSITIVE BENDING, Sn (IN3)
0.289
0.318
0.295
0.327
0.186
0.224
0.222
0.231
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
E C
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
S I
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXCTA\Documents\Revit 2015 Project Files\FY16PN80773BOF_STRUC_R15_K6ENXCTA.rvt
6/30/2016 5:03:35 PM
JU
LY
W
2P M
-1 6-
R -0
C . A tk in s
TJ
D
FY
PN
3B
O F_
S-
1.
D
G N
1-
-2
S-001
G
EN
ER
AL
S T R
U C
T U R
AL
N
O
TE
S
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
6 9 D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
, N O
R
TH
C
AR
O
LI
N A
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SA
VA
N N
AH
D
IS
TR
IC
T
W
ES
T O
G
LE
TH
O
R
PE
A
VE
N U
E
SA
VA
N
N
AH
, G
EO
R G
IA
FO
R
T
BR
AG
G
, N O
R T H
C
AR
O
LI
N A
S O F
BA
T T
AL
IO
N O
PE
R
A T
IO
N S
F A C
IL
IT
Y P N
RTA SUBMITTAL
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
INDEX OF DRAWINGS - STRUCTURAL
SHEET NUMBER SHEET NAME
S-001 GENERAL STRUCTURAL NOTES
S-002 DESIGN DATA
SB101 FOUNDATION PLAN - COMPOSITE
SB102 FOUNDATION PLAN - PART A
SB103 FOUNDATION PLAN - PART B
SB104 FOUNDATION PLAN - PART C
SB105 FOUNDATION PLAN - PART D
SB106 FOUNDATION PLAN - PART E
SB501 FOUNDATION DETAILS
SB502 FOUNDATION DETAILS
SB503 FOUNDATION DETAILS
SB601 FOUNDATION SCHEDULES
SB602 FOUNDATION SCHEDULES
SF101 SECOND FLOOR FRAMING PLAN - COMPOSITE
SF102 SECOND FLOOR FRAMING PLAN - PART A
SF103 SECOND FLOOR FRAMING PLAN - PART B
SF104 SECOND FLOOR FRAMING PLAN - PART C
SF105 SECOND FLOOR FRAMING PLAN - PART D
SF106 SECOND FLOOR FRAMING PLAN - PART E
SF107 ROOF FRAMING PLAN - COMPOSITE
SF108 ROOF FRAMING PLAN - PART A
SF109 ROOF FRAMING PLAN - PART B
SF110 ROOF FRAMING PLAN - PART C
SF111 ROOF FRAMING PLAN - PART D
SF112 ROOF FRAMING PLAN - PART E
SF201 FRAME ELEVATIONS
SF202 FRAME ELEVATIONS
SF203 FRAME ELEVATIONS
SF204 FRAME ELEVATIONS
SF205 FRAME ELEVATIONS
SF206 FRAME ELEVATIONS
SF301 BUILDING SECTIONS
SF302 BUILDING SECTIONS
SF501 FRAMING SECTIONS
SF502 FRAMING DETAILS
SF503 FRAMING DETAILS
SF504 FRAMING DETAILS
SF505 FRAMING DETAILS
SF506 FRAMING DETAILS
SF507 FRAMING DETAILS
SF508 TRUSS PROFILES
SF509 TRUSS PROFILES
SF601 SCHEDULES
DESIGN CODE NOTES:
D-1. STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE FOLLOWING CODES AND
SPECIFICATIONS:
A. IBC 2012, INTERNATIONAL BUILDING CODE
B. ASCE 7-10, MINIMUM DESIGN LOADS FOR BUILDINGS AND STRUCTURES
C. ACI 318-11, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
D. ACI 530-11, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES
E. AISC 360-10, SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
F. AISI S100-07/S2-10, NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD
FORMED STEEL STRUCTURAL MEMBERS, WITH SUPPLEMENT 2, DATED 2010.
G. SDI, STEEL DECK INSTITUTE: DESIGN MANUAL FOR COMPOSITE DECK,
FORM DECK, & ROOF DECK
H. UFC 1-200-01, GENERAL BUILDING REQUIREMENTS, (1 JULY 2013)
I. UFC 3-301-01, STRUCTURAL ENGINEERING, (15 MAY 2014)
J. UFC 3-310-04, SEISMIC DESIGN OF BUILDINGS, (1 JUNE 2013)
K. UFC 4-010-01, DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, (9
JANUARY 2015)
DESIGN LOAD CRITERIA:
D-2. FIRST FLOOR LIVE LOADS:
FIRST FLOOR SLAB ON GRADE U.N.O. 150 PSF
MECHANICAL/ELECTRICAL ROOMS 150 PSF
STORAGE ROOMS 125 PSF
CORRIDOR, STAIRS 100 PSF
D-3. SECOND FLOOR LIVE LOADS:
PARTITION LIVE LOAD 15 PSF
ELEVATED SLABS U.N.O. 80 PSF
LOBBY 100 PSF
CLASSROOMS 100 PSF
MECHANICAL ROOM 150 PSF
STORAGE ROOMS 125 PSF
CENTRAL FILES 250 PSF
D-4. ROOF LIVE LOAD: 20 PSF
D-5. SNOW LOADS:
RISK CATEGORY II
SNOW IMPORTANCE FACTOR, Is 1.0 MINIMUM GROUND SNOW LOAD, Pg 10 PSF SNOW EXPOSURE FACTOR, Ce 0.9 SNOW THERMAL FACTOR, Ct 1.0 ROOF SLOPE FACTOR, Cs 1.0 FLAT ROOF SNOW LOAD, Pf 10 PSF SLOPED ROOF SNOW LOAD, Ps 10 PSF
RAIN ON SNOW LOAD 5 PSF
D-6. WIND LOADS:
RISK CATEGORY II
WIND IMPORTANCE FACTOR, Iw 1.0
BASIC WIND SPEED, V 119 MPH
WIND EXPOSURE CATEGORY C
GUST EFFECT FACTOR, G 0.85
INTERNAL PRESSURE COEFFICIENTS, GCpi +/- 0.18
D-7. SEISMIC LOADS:
RISK CATEGORY II
SEISMIC IMPORTANCE FACTOR, Ie 1.0 MAPPED SPECTRAL RESPONSE ACCELERATION, Ss 0.21
MAPPED SPECTRAL RESPONSE ACCELERATION, S1 0.10
SITE CLASS D
DESIGN SPECTRAL RESPONSE ACCELERATION, Sds 0.224 DESIGN SPECTRAL RESPONSE ACCELERATION, Sd1 0.160
SEISMIC DESIGN CATEGORY C
SEISMIC-FORCE RESISTING SYSTEM STEEL ORDINARY CONCENTRICALLY BRACED FRAMES,
STEEL ORDINARY MOMENT FRAMES
SEISMIC ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE
D-8. ANTI-TERRORISM/FORCE PROTECTION CRITERIA:
NEW BUILDING LOCATION PARKING AND ROADWAYS WITHIN
A CONTROLLED PERIMETER
BUILDING CATEGORY PRIMARY GATHERING BUILDING
DESIGN LEVEL OF THREAT LOW
DESIGN LEVEL OF PROTECTION (LOP) LOW (VLOP)
CONVENTIONAL CONSTR STANDOFF DISTANCE 82 FT
APPLICABLE EXPLOSIVE WEIGHT CLASS II
STEEL DOORS AND FRAMES SPEC 08 11 13
ALUMINUM DOORS AND FRAMES SPEC 08 11 16
ALUMINUM WINDOWS SPEC 08 51 13
GLAZING SPEC 08 81 00
PROGRESSIVE COLLAPSE CRITERIA APPLIES NO (<3 STORIES)
+22 / -35
ZONE
ROOF
BATTALION OPERATIONS FACILITY
COMPONENT AND CLADDING WIND PRESSURES (PSF)
10 SF
EFFECTIVE
WIND
AREA 1
WALLOVERHANG
1. GROSS WIND PRESSURES SHOWN ABOVE CORRESPOND TO WIND PRESSURE DIAGRAMS SHOWN
BELOW.
2. EDGE ZONES 'a' = 12'-0" 2-STORY 5-12 ; 'a' = 6'-0" 1-STORY 1/2-12
3. WIND PRESSURES SHOWN SHALL BE USED IN CONJUNCTION WITH LOAD COMBINATIONS
SPECIFIED IN SECTIONS 2.3 AND 2.4 OF ASCE 7-10.
4. NEGATIVE WIND PRESSURES REPRESENT GOVERNING WIND PRESSURES ACTING AWAY FROM
THE COMPONENT AND CLADDING SURFACES.
5. PARAPET WIND PRESSURES INDICATED ARE THE COMBINATION OF THE POSITIVE WALL
PRESSURE PLUS THE ADJACENT NEGATIVE ROOF PRESSURE.
20 SF
50 SF
100 SF
+20 / -34
+17 / -32
+15 / -31
+22 / -60
+20 / -55
+17 / -49
+15 / -44
+22 / -89
+20 / -83
+17 / -76
+15 / -70
+38 / -41
+36 / -39
+34 / -38
+31 / -34
+38 / -51
+36 / -47
+34 / -43
+31 / -41
-76
-76
-76
-76
-124
-113
-97
-86
ZONE 2 ZONE 3 ZONE 4 ZONE 5ZONE 2 ZONE 3
+13 / -31
ZONE
ROOF
LOW SLOPE - LEAN TO PORTION
COMPONENT AND CLADDING WIND PRESSURES (PSF)
10 SF
EFFECTIVE
WIND
AREA 1
WALL PARAPET
20 SF
50 SF
100 SF
+11 / -30
+10 / -29
+10 / -28
+13 / -52
+11 / -47
+10 / -39
+10 / -34
+13 / -78
+11 / -65
+10 / -47
+10 / -34
+31 / -34
+29 / -32
+28 / -31
+26 / -28
+31 / -41
+29 / -39
+28 / -35
+26 / -34
+/- 83
+/- 76
+/- 67
+/- 60
+/- 109
+/- 94
+/- 75
+/- 60
ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 4 ZONE 5
OVERHANG
-62
-62
-62
-62
-102
-93
-79
-70
ZONE 2 ZONE 3
'a'=12' (TYP)'a'=12'
(TYP)
'a'=6'
(TYP)
1 1
3 3 3
3 3 3
This is the start of the file's text. The full file is on GovTribe.