BB_Pump_Stations_ADV_Plans_split_Part9.pdf
PDF 10 MB Posted
- Attached to
- Bois Brule Pump Stations
- Solicitation number
- W912P9-16-R-0027
About this file
Plans - 9 of 13
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CL
PL
N O
B M
M A
L S
M -B
B -1
W P -X
:1
A N
S I
D
S-001
S T
R U
C T
U R
A L
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
S T L
O U
IS
D
IS
T R
IC
T
S T L
O U
IS
M
IS
S O
U R I
W P -1
-R -0
M -B
B -1
S -0
N T S .d g n
J O
S H
U A S
V E
R D
U G
H T P .E
S T
E V
E N M
H O
B B
S P .E
P E
R R
Y C
O U
N T
Y
M O
G E
N E
R A
L S
T R
U C
T U
R A
L N
O T
E S
A N
D A
B B
R E
V
IA
T
IO
N S
B O
IS
B
R U
L E L
E V
E E A
N D D
R A
IN
A G
E D
IS
T R
IC
T
C
IN
Q U
E H
O M
M E
S P
U M
P S
T A
T
IO
N N
O
L O
W E
R M
IS
S
IS
S
IP
P I
THE CONSTRUCTION JOINTS SHOWN ON THE DRAWINGS INDICATE THE MAXIMUM PERMISSIBLE HEIGHTS OF CONCRETE LIFTS.
GENERAL REGULATIONS AND DESIGN LOADS
GENERAL REGULATIONS:
CONSTRUCTION JOINTS:
DESIGN LOADS:
REINFORCEMENT
SMALLER LIFTS MAY BE PLACED IF APPROVED BY THE CONTRACTING OFFICER. CONTRACTOR MAY SUBMIT ALTERNATE
PUMP STATION BASE SLAB - TOP = 4"
BOTTOM = 4"
PUMP STATION WALLS - BOTH FACES = 4"
FROM 3" TO 6" FROM JOINT, SUBJECT TO THE APPROVAL OF THE CONTRACTING OFFICER.
SEQUENCE OF CONSTRUCTION. AT CONSTRUCTION JOINTS, FIRST AND LAST REINFORCEMENT HORIZONTAL BAR SHALL BE PLACED
LATERAL EARTH PRESSURES - APPLICABLE SOIL PRESSURES BASED ON THE FOLLOWING SOIL PROPERTIES
REGULATIONS:
STRENGTH AND TYPE:
ALL CONCRETE SHALL BE NORMAL WEIGHT AND HAVE A MINIMUM COMPRESSIVE STRENGTH (f’c) of 4000 PSI AT 28 DAYS.
CHAMFERS:
FINISHES:
CONCRETE
SEISMIC:
" UNLESS OTHERWISE NOTED.4
CHAMFER ALL EDGES OF BEAMS, WALLS, AND SLABS EXPOSED TO VIEW
- EM 1110-2-2104, STRENGTH DESIGN FOR REINFORCED CONCRETE HYDRAULIC STRUCTURES, 20 AUG. 2003.
ELEVATED FLOOR SLABS AND BEAMS - TOP, BOTTOM AND SIDES = 2"
COMPACTED PERVIOUS BACKFILL :
- SEE SPECIFICATIONS FOR FINISH REQUIREMENTS FOR ALL CONCRETE SURFACES.
- UNFORMED SURFACE FINISH REQUIREMENTS:
BROOM FINISH - EXTERIOR ELEVATED WALKWAY SLABS, ALL SLAB-ON-GRADES
FLOAT FINISH - INTERIOR PUMP STATION OPERATING FLOOR
REGULATIONS:
- ANCHOR BOLTS - ASTM A307
- HIGH STRENGTH BOLTS - ASTM A325
- ALL ROLLED SECTIONS AND PLATE UNLESS NOTED OTHERWISE - ASTM A36.
- ALL ROLLED WIDE FLANGE SHAPES - ASTM A992.
STRUCTURAL STEEL
MISCELLANEOUS
- WELDING ELECTRODES - E70XX, ALL TYPES OF WELDS
- STEEL H-PILE - ASTM A572, GRADE 50
MATERIAL:
- STEEL PIPE - ASTM A53, TYPE E OR S, GRADE B
FOR THE PROJECT.
ANCHORAGE DETAILS AND LOCATIONS ASSOCIATED WITH STANDARD ARTICLES, WITH ACTUAL ITEMS FURNISHED
- VERIFY DIMENSIONS OF OPENINGS IN SLABS AND WALLS, AND ASSOCIATED SURROUNDING CONSTRUCTION, AND
SHORED AND BRACED TO WITHSTAND LATERAL SOIL PRESSURES UPON APPROVAL OF THE CONTRACTING OFFICER.
BEEN PLACED AND THE SPECIFIED COMPRESSIVE STRENGTH HAS BEEN ATTAINED OR WALLS HAVE BEEN PROPERLY
- BACKFILL AROUND PUMP STATION WALLS SHALL NOT BE PLACED UNTIL OPERATING FLOOR SLAB CONCRETE HAS
PRESSURES.
AND APPROVED. BACKFILL SHALL BE PLACED EVENLY AROUND STRUCTURES TO AVOID UNEQUAL LATERAL
- BACKFILLING AROUND STRUCTURES SHALL NOT BEGIN UNTIL CONSTRUCTION BELOW GRADE HAS BEEN INSPECTED
TYPICAL JOINT DETAILS
ABBREVIATIONS
ALTERNATE
BEAM
BOTTOM
BEARING
BENT
CENTER TO CENTER
CAST IRON PIPE
CONSTRUCTION JOINT
CENTERLINE
CLEAR
CONCRETE
CONTINUOUS
CENTERED
DETAIL
DIMENSION
DRAWING
DOWEL
EACH
EACH FACE
ELEVATION
EQUALLY SPACED
FLOOR
FAR SIDE
GALVANIZED
HORIZONTAL
HIGH POINT
HEIGHT
INSIDE DIAMETER
LEFT HAND
JOINT
LOW POINT
MAXIMUM
MINIMUM
MANUFACTURER
PLATE
NUMBER
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
OPENING
OPPOSITE
POUNDS PER SQUARE INCH
RADIUS
REINFORCED CONCRETE PIPE
REINFORCEMENT
REQUIRED
RIGHT HAND
SCHEDULE
SECTION
SPECIFICATION
SQUARE
STAINLESS STEEL
STANDARD
THREAD
TYPICAL
UNLESS NOTED OTHERWISE
VERTICAL
WORKING POINT
YIELD POINT
FLANGE
ADD’L. ADDITIONAL
FLOOR DRAIN
TOP OF SLAB
ANCHOR BOLT
CONTRACTION
DOWNSTREAM
EXPANSION
UPSTREAM
FIBER REINFORCED PLASTIC
CMP
CONST.
CORRUGATED METAL PIPE
CONNECTION
CONSTRUCTION
EXIST EXISTING
W/ WITH
DIAMETER
A.B.
CONN.
Y.P.
W.P.
VERT.
US
UNO
TYP.
T/S
THD.
STD.
S.S.
SQ.
SPEC.
SECT.
SCHED.
R.H.
REQ’D.
REINF.
RCP
RAD.
PSI
OPP.
OPNG.
O.D.
O.C.
NTS
NO.
MFR.
MIN.
MAX.
L.P.
JT.
L.H.
HT
H.P.
I.D.
GALV.
FS
FRP
FLG.
FL.
F.D.
EXP.
EQ. SPC.
E.F.
EA
DWL.
DWG.
DIM.
DS
DET.
CTRD.
CONTR.
CONT.
CONC.
CL
C.J.
C.I.P
C.C.
BT
BRG.
BOT.
BM.
ALT.
EW EACH WAY
FAR FACE
HD. HEADED
LG LONG
NEAR FACE
NS NEAR SIDE
T&B TOP AND BOTTOM
HORIZ.
NPS NOMINAL PIPE SIZE
SYMM. SYMMETRICAL
EL.
THICKTHK.
F.F.
N.F.
DIA.
GENERAL STRUCTURAL NOTES
115 MPH
0.072g OPERATING BASIS EARTHQUAKE
0.212g MAXIMUM DESIGN EARTHQUAKE
- BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, ACI 318-14.
- ASCE 7-10, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
- EM 1110-2-2906, DESIGN OF PILE FOUNDATIONS, 15 JAN 91.
- EM 1110-2-2502, RETAINING AND FLOOD WALLS, 29 SEP 89.
- EM 1110-2-2100, STABILITY ANALYSIS OF CONCRETE STRUCTURES, 1 DEC 2005.
- EM 1110-2-2902, CONDUITS, CULVERTS AND PIPES, 31 MAR 1998.
- EM 1110-2-3104, STRUCTURAL AND ARCHITECTURAL DESIGN OF PUMP STATIONS, 30 JUN 89.
- ETL 1110-2-584, DESIGN OF HYDRAULIC STEEL STRUCTURES, 30 JUN 2014.
- AISC STEEL CONSTRUCTION MANUAL, 14TH EDITION.
UNLESS OTHERWISE NOTED.
- ELEVATIONS SHOWN ARE REFERENCED FROM THE NORTH AMERICAN VERTICAL DATUM (N.A.V.D) 1988, WELDING CODE AWS D1.5, UNLESS OTHERWISE NOTED.
- WELDING SHALL BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY BRIDGE
- ALL TRASH RACK STEEL- ASTM A709
ALL REINFORCEMENT SHALL HAVE THE FOLLOWING CLEAR CONCRETE COVER UNLESS SHOWN OTHERWISE:
BENDING AND PLACEMENT OF REINFORCEMENT SHALL BE IN ACCORDANCE WITH "ACI DETAILING MANUAL - 2004, SP-66(04).
WHERE NECESSARY TO AVOID OPENINGS, PIPES, EMBEDDED ITEMS AND OTHER OBSTRUCTIONS.
SUBJECT TO THE APPROVAL OF THE CONTRACTING OFFICER, BARS MAY BE SHIFTED SLIGHTLY OR BENT IN THE FIELD
THE SMALLER BAR.
WHERE BARS HAVING DIFFERENT DIAMETERS ARE TO BE SPLICED, THE SPLICE LENGTH SHALL BE GOVERNED BY
ALL HOOKS NOT NOTED ARE STANDARD HOOKS IN ACCORDANCE WITH ACI 318-14.
REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60.
LENGTH
EMBEDMENT
LAP LENGTH
MINIMUM
SIZES
BAR
BARS
TOP**
BARS
TOP**
BARS
OTHER
BARS
OTHER
#3
#4
#5
#6
#7
#8
#9
#10
#11
EMBEDMENTS AND LAPS
TABLE OF REINFORCEMENT
CONCRETE IS CAST BELOW THE BAR.
SO THAT MORE THAN 12" OF FRESH
TOP BAR IS DEFINED AS ANY BAR PLACED
THE VALUES IN THE TABLE MAY BE
SPACED LATERALLY AT 6" ON CENTERS
WITH AT LEAST 3" CLEAR COVER, BUT
VALUES SHALL NOT BE LESS THAN 12".
LENGTH
EMBEDMENT
LAP LENGTH
MINIMUM
SIZES
BAR
BARS
TOP**
BARS
TOP**
BARS
OTHER
BARS
OTHER
#3
#4
#5
#6
#7
#8
#9
#10
#11
AREAS WHERE REINFORCEMENT IS
1915 25
25 2532
31 3124 41
37 3729 49
54 5442 71
62 6248 81
70 7054 91
79 7961 102
87 8767 114
MODIFIED BY MULTIPLYING BY 0.8 IN
WIND SPEED:
CONTROL JOINT
SURCHARGE/ LIVE LOAD = 300 PSF
SOIL WT = 125 PCF
Ø= 35 DEG. C = 0 PSF
WITH SEALANT.
PLACEMENT. FILL JOINT
AFTER CONCRETE
" SLOT 4 TO 12 HRS 4
1SAW
SLAB REINF.
2ND POUR
"H)4 1(MIN. 1"Wx
WATERSTOP
HYDROPHILIC
REINF.
CONTINUOUS
1ST POUR
C.J. LOCATION
CONSTRUCTION JOINT
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R fiof Engineers
US Army Corps
J U
N E
File details come from the government source that posted it. Updated .