RFI__4.pdf

PDF 259 KB Posted

Attached to
Cleveland Drydocking Services Federal contract opportunity
Solicitation number
W912P4-16-R-0001
Issued by
Department of the Army Corps of Engineers Engineering District Buffalo

About this file

Please see attached response to question in attachment.

View the file

Other files for this federal contract opportunity

Other files attached to Cleveland Drydocking Services, newest first.
File Type Posted
Bid_Abstract_19Nov2015_.xlsx XLSX spreadsheet
Amendment_05_16Nov2015.pdf PDF
Amendment_04_13Nov2015.pdf PDF
RFI__5.pdf PDF
McCauley_Additional_Drawings_09Nov_2015.pdf PDF
CORRECTED_Amendment_03_09Nov2015.pdf PDF
McCauley_Additional_Drawings_09Nov_2015.pdf PDF
Amendment_03_09Nov2015.pdf PDF
Amendment_02_06Nov2015.pdf PDF
Amendment_01_05Nov2015.pdf PDF
Final_Solicitation_03Nov2015.pdf PDF
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RFI #3, Received Monday, November 09, 2015 4:50 PM.

Question 1: I am inquiring about item 9: “Replace the 12” diameter Schedule 80 split steel pipe fendering that protects the joints between the side plating and the bottom plate, and between the side plating and the underside of the rake (refer to Drawing Detail S).” Can you tell me if the 12” pipe wall is a .500 or .688?

Answer 1: This question points out that there is a difference between Extra Strong (0.500” wall thickness) and Schedule 80 (0.688” wall thickness) for 12” Nominal Pipe Size. The record drawings show

Extra Strong for the original pipe fendering. The language of Item 5 and Item 9 requires the new 12” pipe fendering to be Schedule 80 (0.688” wall).