Text version

CLIN 0001) Magnetic Particle Inspection Bench - Quantity 1 EA Meet or exceed the following Essential Physical Characteristics:

· Required to support a minimum of a 54 inch part length capacity

· Required to have a minimum of a 16 inch inside diameter coil for smaller components that require current applied circumferentially

· Must have a digital Ammeter with a 1% accuracy or less, and a reading hold function

· Must be large enough to support two technicians working at the same time

· Ability to connect and operate off the buildings power supply of

· 3 Phase, 480v, 60 Hertz electrical connection

· Must have an AC and DC function

· Stationary Magnetic Bench must have 500 to 3,500 AMPs range DC capability

· Stationary Magnetic Bench must have 500 to 1,500 AMPs range AC capability

· Must be of commercial grade, ability to handle high use daily operations.

· Unit shall include a minimum of 1 year warranty.

· Vendor shall provide installation and set-up

· Unit must include training for up to 5 individuals on the installed system Recommend Systems

· MAGWERKS – PSF-546

· Gould-Bass – Model 3504

· MAGNAFLUX – AD-2045

CLIN 0002) Demagnetizer - Quantity 1 EA Meet or exceed the following Essential Physical Characteristics:

· Required to have a Free Standing Intermittent Duty Demagnetizer with a minimum of a 14 X 16 inch opening so all components can fit through

· AC Demagnetizer with a range at least up to 8,000 Ampere-Turn Rating

· Ability to connect and operate off the buildings power supply of

· 240 VAC, 60 HZ, 1 phase power requirements

· Non Ferrous Coil Core

· Control Unit mounted on Demagnetizer

· Must be of commercial grade, ability to handle high use daily operations.

· Unit shall include a minimum of 1 year warranty.

· Vendor shall provide installation and set-up

· Unit must include training for up to 5 individuals on the installed system

Recommended Systems that meet characteristics

MAGWERKS - FM-1416
Gould-Bass – 3534B
MAGNAFLUX – SB-1416