Purchase Description - Magnetic Particle Inspection Bench and Demagnetizer
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Summary_of_Questions_Asked.docx | DOCX document | |
| A2-3_-_REVISION__2_-_Purchase_Description_-_Magnetic_Particle_Inspection_Bench_and_Demagnetizer.docx | DOCX document | |
| Questions.docx | DOCX document | |
| Combined_Synopsis_-_Solicitation_.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLIN 0001) Magnetic Particle Inspection Bench - Quantity 1 EA Meet or exceed the following Essential Physical Characteristics:
· Required to support a minimum of a 54 inch part length capacity
· Required to have a minimum of a 16 inch inside diameter coil for smaller components that require current applied circumferentially
· Must have a digital Ammeter with a 1% accuracy or less, and a reading hold function
· Must be large enough to support two technicians working at the same time
· Ability to connect and operate off the buildings power supply of
· 3 Phase, 480v, 60 Hertz electrical connection
· Must have an AC and DC function
· Stationary Magnetic Bench must have 500 to 3,500 AMPs range DC capability
· Stationary Magnetic Bench must have 500 to 1,500 AMPs range AC capability
· Must be of commercial grade, ability to handle high use daily operations.
· Unit shall include a minimum of 1 year warranty.
· Vendor shall provide installation and set-up
· Unit must include training for up to 5 individuals on the installed system Recommend Systems
· MAGWERKS – PSF-546
· Gould-Bass – Model 3504
· MAGNAFLUX – AD-2045
CLIN 0002) Demagnetizer - Quantity 1 EA Meet or exceed the following Essential Physical Characteristics:
· Required to have a Free Standing Intermittent Duty Demagnetizer with a minimum of a 14 X 16 inch opening so all components can fit through
· AC Demagnetizer with a range at least up to 8,000 Ampere-Turn Rating
· Ability to connect and operate off the buildings power supply of
· 240 VAC, 60 HZ, 1 phase power requirements
· Non Ferrous Coil Core
· Control Unit mounted on Demagnetizer
· Must be of commercial grade, ability to handle high use daily operations.
· Unit shall include a minimum of 1 year warranty.
· Vendor shall provide installation and set-up
· Unit must include training for up to 5 individuals on the installed system
Recommended Systems that meet characteristics
| MAGWERKS - FM-1416 |
| Gould-Bass – 3534B |
| MAGNAFLUX – SB-1416 |
File details come from the government source that posted it.