PAANG_301_302_Combined_Specs_Vol.1.pdf

PDF 9 MB Posted

Attached to
REPAIR HANGARS B301 & B302 Federal contract opportunity
Solicitation number
W912KC-17-R-0001
Issued by
Department of the Army Pennsylvania Army National Guard

About this file

Specs Vol 1. Updated 8 February 2017

View the file

Other files for this federal contract opportunity

Other files attached to REPAIR HANGARS B301 & B302, newest first.
File Type Posted
AMENDMENT_4_-_W912KC-17-R-0001_-_REPAIR_B301-B302.pdf PDF
AMENDMENT_2_-_W912KC-17-R-0001-0001_-_REPAIR_B301-B302.pdf PDF
20120309-135148.PDF PDF
20120309-140019.PDF PDF
20120314-104233.PDF PDF
20120309-135755.PDF PDF
20120314-111039.PDF PDF
20120309-135905.PDF PDF
20120309-135615.PDF PDF
20120309-133712.PDF PDF
20120314-110802.PDF PDF
20120309-135023.PDF PDF
20120314-104643.PDF PDF
20120309-140829.PDF PDF
AMENDMENT_1_-_W912KC-17-R-0001-J-0001_-_REPAIR_B301-B302.pdf PDF
PA_ANG_301_-_Kitchen.pdf PDF
QA_Master_Document_20170413.pdf PDF
Sign_In_Roster_2_W912KC-R-17-0001.pdf PDF
Q&A_Master_Document_20170407.pdf PDF
AMENDMENT_4_W912KC-17-R-0001.pdf PDF
AMENDMENT_4_W912KC-17-R-0001.pdf PDF
AMENDMENT_3_RFI_FINAL.PDF PDF
ASK-001.pdf PDF
ATFP_Plan.pdf PDF
Ansulite_3__AFFF_(AFC-5-A)_SDS.PDF PDF
Amendment_2_W912KC-R-0001.pdf PDF
171st-AC_Air_Permit_and_Requirements.pdf PDF
07_21_29_-_Sprayed_Insulation.pdf PDF
Site_Visit_20170206.pptx PPTX presentation
Amendment_1__W912KC-17-R-0001.pdf PDF
B302_Part_5_Drawings.pdf PDF
B302_Part_9_Drawings.pdf PDF
B302_Part_10_Drawings.pdf PDF
B301_Part_2_Drawings.pdf PDF
B301_Part_4_Drawings.pdf PDF
B301_Part_9_Drawings.pdf PDF
B301_Part_1_Drawings.pdf PDF
B302_Part_1_Drawings.pdf PDF
B301_Part_5_Drawings.pdf PDF
B301_Part_8_Drawings.pdf PDF
B302_Part_6_Drawings.pdf PDF
B302_Part_7_Drawings.pdf PDF
B302_Part_8_Drawings.pdf PDF
B301_Part_7_Drawings.pdf PDF
BLDG_301_Specs_&_Drawings_Part_2.pdf PDF
BLDG_302_Specs_&_Drawings_Part_2.pdf PDF
BLDG_301_Specs_&_Drawings_Part_1.pdf PDF
EXHIBIT_C_B301_B302_Hangar_Repairs.pdf PDF
BLDG_302_Specs_&_Drawings_Part_1.pdf PDF
Solicitation_W912KC-17-R-0001.pdf PDF
Show all 50

REPAIR HANGARS B301 & B302 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ISSUED FOR RFP

SPECIFICATIONS

VOLUME 1 of 2

REPAIR HANGAR 301 & REPAIR HANGAR 302

Pittsburgh International Airport, PA

W90FYQ-09-D-0004-DL03

Prepared For:

Prepared By:

3500 Parkway Lane, Suite 600

Norcross, Georgia 30092 678.336.7740 www.pondco.com

3 JUNE 2016

Project No. 1140370

171st Air Refueling Wing Pittsburgh International Airport Coraopolis, PA

THIS PAGE INTENTIONALLY LEFT BLANK

PA ANG Repair Hangars 301 and 302

PROJECT TABLE OF CONTENTS

DIVISION 01 - GENERAL REQUIREMENTS

01 11 00 SUMMARY OF WORK

01 14 00 WORK RESTRICTIONS

01 20 00.00 20 PRICE AND PAYMENT PROCEDURES

01 30 00 ADMINISTRATIVE REQUIREMENTS

01 32 17.00 20 NETWORK ANALYSIS SCHEDULES (NAS)

01 33 00 SUBMITTAL PROCEDURES

01 33 29 SUSTAINABILITY REPORTING

01 35 13 SPECIAL PROJECT PROCEDURES

01 35 40.00 20 ENVIRONMENTAL MANAGEMENT

01 42 00 SOURCES FOR REFERENCE PUBLICATIONS

01 45 00.00 10 QUALITY CONTROL

01 45 00.10 10 QUALITY CONTROL SYSTEM (QCS)

01 45 35 SPECIAL INSPECTIONS

01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS

01 52 13 TEMPORARY MODULAR SPACE

01 57 16 TEMPORARY PEST CONTROL

01 57 19.00 20 TEMPORARY ENVIRONMENTAL CONTROLS

01 57 20.00 10 ENVIRONMENTAL PROTECTION

01 62 35 RECYCLED / RECOVERED MATERIALS

01 74 19 CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT

01 75 00 STARTING AND ADJUSTING

01 78 00 CLOSEOUT SUBMITTALS

01 78 23 OPERATION AND MAINTENANCE DATA

01 91 00.00 40 COMMISSIONING

DIVISION 02 - EXISTING CONDITIONS

02 82 16.00 20 ENGINEERING CONTROL OF ASBESTOS CONTAINING MATERIALS

02 82 33.13 20 REMOVAL/CONTROL AND DISPOSAL OF PAINT WITH LEAD

DIVISION 03 - CONCRETE

03 30 00 CAST-IN-PLACE CONCRETE

03 30 10 CONCRETE STRENGTHENING USING FIBER REINFORCED POLYMERS

DIVISION 04 - MASONRY

04 20 00 MASONRY

DIVISION 05 - METALS

05 12 00 STRUCTURAL STEEL

05 21 00 STEEL JOIST FRAMING

05 30 00 STEEL DECKS

05 40 00 COLD-FORMED METAL FRAMING

05 50 13 MISCELLANEOUS METAL FABRICATIONS

05 52 00 METAL RAILINGS

DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES

06 10 00 ROUGH CARPENTRY

06 41 16.00 10 LAMINATE CLAD ARCHITECTURAL CASEWORK

06 61 16 SOLID SURFACING FABRICATIONS

DIVISION 07 - THERMAL AND MOISTURE PROTECTION

PROJECT TABLE OF CONTENTS Page 1

07 11 13 BITUMINOUS DAMPPROOFING

07 13 53 ELASTOMERIC SHEET WATERPROOFING

07 21 13 BOARD AND BLOCK INSULATION

07 22 00 ROOF AND DECK INSULATION

07 41 13 METAL ROOF PANELS

07 42 63 FABRICATED WALL PANEL ASSEMBLIES

07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING

07 60 00 FLASHING AND SHEET METAL

07 84 00 FIRESTOPPING

07 92 00 JOINT SEALANTS

DIVISION 08 - OPENINGS

08 11 13 STEEL DOORS AND FRAMES

08 14 00 WOOD DOORS

08 33 23 OVERHEAD COILING DOORS

08 34 59 DAY GATES

08 41 13 ALUMINUM-FRAMED ENTRANCES, STOREFRONTS AND CURTAINWALL

08 71 00 DOOR HARDWARE

08 81 00 GLAZING

08 91 00 METAL WALL AND DOOR LOUVERS

DIVISION 09 - FINISHES

09 22 00 SUPPORTS FOR PLASTER AND GYPSUM BOARD

09 29 00 GYPSUM BOARD

09 30 13 CERAMIC TILING

09 51 00 ACOUSTICAL CEILINGS

09 62 38 STATIC-CONTROL FLOORING

09 65 00 RESILIENT FLOORING

09 67 23.15 FUEL RESISTIVE RESINOUS FLOORING, 3-COAT SYSTEM

09 67 23.16 FUEL RESISTIVE RESINOUS FLOORING, 5-COAT SYSTEM

09 68 00 CARPETING

09 90 00 PAINTS AND COATINGS

DIVISION 10 - SPECIALTIES

10 10 00 VISUAL COMMUNICATIONS SPECIALTIES

10 14 00.20 INTERIOR SIGNAGE

10 21 13 TOILET COMPARTMENTS

10 22 13 WIRE MESH PARTITIONS

10 22 19 DEMOUNTABLE MOVABLE PARTITIONS

10 22 39 FOLDING PANEL PARTITIONS

10 26 13 WALL AND CORNER GUARDS

10 28 13 TOILET ACCESSORIES

10 44 16 FIRE EXTINGUISHERS

10 51 13 METAL LOCKERS

10 55 00 POSTAL SPECIALTIES

DIVISION 11 - EQUIPMENT

11 06 40.13 FOODSERVICE EQUIPMENT SCHEDULE

DIVISION 12 - FURNISHINGS

12 21 00 WINDOW BLINDS

12 48 13 ENTRANCE FLOOR MATS AND FRAMES

PROJECT TABLE OF CONTENTS Page 2

DIVISION 14 - CONVEYING EQUIPMENT

14 21 23 ELECTRIC TRACTION PASSENGER ELEVATORS

DIVISION 21 - FIRE SUPPRESSION

21 13 13.00 10 WET PIPE SPRINKLER SYSTEM, FIRE PROTECTION

21 13 18.00 10 PREACTION AND DELUGE SPRINKLER SYSTEMS, FIRE PROTECTION

21 13 25.00 HIGH-EXPANSION FOAM FIRE PROTECTION SYSTEM

21 21 03.00 10 WET CHEMICAL FIRE EXTINGUISHING SYSTEM

21 30 00 FIRE PUMPS

DIVISION 22 - PLUMBING

22 00 00 PLUMBING, GENERAL PURPOSE

22 15 13.16 40 HIGH-PRESSURE COMPRESSED-AIR PIPING, PIPING COMPONENTS,

AND VALVES

DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING

23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS

23 03 00.00 20 BASIC MECHANICAL MATERIALS AND METHODS

23 05 15 COMMON PIPING FOR HVAC

23 05 48.00 40 VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND

EQUIPMENT

23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC

23 07 00 THERMAL INSULATION FOR MECHANICAL SYSTEMS

23 08 00.00 10 COMMISSIONING OF HVAC SYSTEMS

23 09 13.34 40 CONTROL VALVES, SELF-CONTAINED

23 09 23.13 20 BACnet DIRECT DIGITAL CONTROL SYSTEMS FOR HVAC

23 11 25 FACILITY GAS PIPING

23 23 00 REFRIGERANT PIPING

23 25 00 CHEMICAL TREATMENT OF WATER FOR MECHANICAL SYSTEMS

23 31 13.00 40 METAL DUCTS

23 37 13.00 40 DIFFUSERS, REGISTERS, AND GRILLS

23 52 43.00 20 LOW PRESSURE WATER HEATING BOILERS (UNDER 800,000 BTU/HR

OUTPUT)

23 64 26 CHILLED, CHILLED-HOT, AND CONDENSER WATER PIPING SYSTEMS

23 65 00 COOLING TOWERS

23 82 00.00 20 TERMINAL HEATING AND COOLING UNITS

23 84 16.00 20 DESICCANT DEHUMIDIFICATION EQUIPMENT

DIVISION 26 - ELECTRICAL

26 00 00.00 20 BASIC ELECTRICAL MATERIALS AND METHODS

26 12 19.10 THREE-PHASE PAD-MOUNTED TRANSFORMERS

26 20 00 INTERIOR DISTRIBUTION SYSTEM

26 23 00 LOW-VOLTAGE SWITCHGEAR

26 28 00.00 10 MOTOR CONTROL CENTERS, SWITCHBOARDS AND PANELBOARDS

26 29 23 VARIABLE FREQUENCY DRIVE SYSTEMS UNDER 600 VOLTS

26 32 14.00 10 DIESEL-GENERATOR SET, STATIONARY 15-300 KW, STANDBY

APPLICATIONS

26 36 00.00 10 AUTOMATIC TRANSFER SWITCH AND BY-PASS/ISOLATION SWITCH

26 51 00 INTERIOR LIGHTING

DIVISION 27 - COMMUNICATIONS

27 05 29.00 10 PROTECTIVE DISTRIBUTION SYSTEM (PDS) FOR SIPRNET

COMMUNICATION SYSTEMS

PROJECT TABLE OF CONTENTS Page 3

27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM

DIVISION 28 - ELECTRONIC SAFETY AND SECURITY

28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM

DIVISION 31 - EARTHWORK

31 00 00 EARTHWORK

31 11 00 CLEARING AND GRUBBING

31 31 16.13 CHEMICAL TERMITE CONTROL

DIVISION 32 - EXTERIOR IMPROVEMENTS

32 01 19 FIELD MOLDED SEALANTS FOR SEALING JOINTS IN RIGID

PAVEMENTS

32 11 16 BASE COURSE FOR RIGID PAVING

32 12 16 HOT-MIX ASPHALT (HMA) FOR ROADS

32 13 13.06 PORTLAND CEMENT CONCRETE PAVEMENT FOR ROADS AND SITE

FACILITIES

32 16 13 CONCRETE SIDEWALKS AND CURBS AND GUTTERS

32 92 19 SEEDING

DIVISION 33 - UTILITIES

33 11 00 WATER DISTRIBUTION

33 16 15 WATER STORAGE STEEL TANKS

33 30 00 SANITARY SEWERS

33 40 00 STORM DRAINAGE UTILITIES

33 71 02 UNDERGROUND ELECTRICAL DISTRIBUTION

33 82 00 TELECOMMUNICATIONS OUTSIDE PLANT (OSP)

DIVISION 41 - MATERIAL PROCESSING AND HANDLING EQUIPMENT

41 22 13 JIB CRANE

-- End of Project Table of Contents --

PROJECT TABLE OF CONTENTS Page 4

SECTION 01 11 00

SUMMARY OF WORK

08/11

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM E2114 (2008) Standard Terminology for Sustainability Relative to the Performance of Buildings

1.2 DEFINITIONS

Definitions pertaining to sustainable development are as defined in ASTM E2114, Section 01 35 40.00 20 ENVIRONMENTAL MANAGEMENT and Section 01 57 20.00 10 ENVIRONMENTAL PROTECTION, and as specified.

a. "Environmentally preferable products" have a lesser or reduced effect on the environment in comparison to conventional products and services. This comparison may consider raw materials acquisition, production, manufacturing, packaging, distribution, reuse, operation, maintenance, or disposal of the product.

b. "Indoor environmental quality" is the physical characteristics of the building interior that impact occupants, including air quality, illumination, acoustics, occupant control, thermal comfort, daylighting, and views.

c. "Operational performance" is the functional behavior of the building as a whole or of the building components.

d. "Sustainability" is the balance of environmental, economic, and societal considerations.

1.3 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. The following shall be submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-01 Preconstruction Submittals

Upon receipt of Government Furnished Equipment, the Contractor shall submit records in accordance with paragraph entitled, "Government Furnished Property," of this section.

Submit the following items to the Contracting Officer or Contracting Officer's Representative :

SECTION 01 11 00 Page 1

Utility Outage Requests Utility Connection Requests Borrow Permits Excavation Permits Welding Permits Burning Permits

SD-07 Certificates

Energy Performance Rating

1.4 WORK COVERED BY CONTRACT DOCUMENTS

1.4.1 Project Description

The work includes renovation/repair of Buildings 301 and 302 . Also included is associated site and utilities and incidental related work.

1.4.2 Location

The work shall be located at Buildings 301 and 302. Pennsylvania Air National Guard Base, Pittsburgh, Pennsylvania International Airport, Coraopolis, PA. approximately as indicated. The exact location will be shown by the Contracting Officer.

1.4.3 Project Phasing & Du rations

The project construction shall be executed in the phasing sequence indicated below. Each phase shall be completed in its entirety before the next phase is started. All close out documents shall be submitted to the Contracting Officer's Representative as prescribed by section 01 78 00, CLOSEOUT SUBMITTALS at the completion of each phase. The contractor is responsible for determining the sequence of work within each described phase. See G-sheet drawings for limits of work for each phase, locations of swing spaces, specific requirements for each user, and lists of specific equipment required to be relocated

At any given time, a minimum of one hangar bay between Buildings 301 and 302 shall be fully operational for military mission activities. A fully operational hangar is defined as a facility that is unimpeded by all construction activities and can be fully accessed and used by the Government. The project phasing indicated herein and on the G-sheet drawings is intended to maintain this requirement throughout the duration of the project

The contracting officer shall provide a written notice to proceed after the completion of each phase to the contractor before work can begin for the subsequent phase. The total project duration shall be 1,000 calendar days from initial written notice to proceed from the beginning of Phase 1 to the end of Phase 7.

1.4.3.1 Descriptions of Phasing and Durations

Phase 1:

a. All of civil site work

b. Construction of fire tanks, pump house, pumps, and lines between

SECTION 01 11 00 Page 2 pumps and HEF room. All fire protection equipment shall installed in the pump house, tested, and accepted.

c. Construction of new Mechanical, Electrical, and HEF room.

d.Move occupants out of Building 302 into fully prepared swing spaces

The contractor shall complete work in Phase 1 within 210 calendar days from the notice to proceed. The contractor shall notify the contracting officer's representative when work is complete and all close out documents have been submitted. The contracting officer's representative shall have a maximum of 14 calendar days to review the submitted close out documents and, if all contractor requirements have been met, a notice to proceed will be provided for phase 2

Phase 2:

a. Move occupants out of Building 302 into fully prepared swing spaces.

The contractor does not need a notice to proceed to continue work for Phase 3.

Phase 3:

a. Abatement of lead and asbestos materials in Building 302.

b. Renovation work of Building 302.

c. Mechanical system shall be tested and balanced. Commissioning and verification shall be performed on mechanical systems.

d. Complete electrical, security and communication systems are to be installed, verified and commissioned for building 302. Including but not limited to new electrical distribution, generator and inverters.

e. Submission of close out documents

The contractor shall complete work in Phases 2 and 3 within 330 calendar days from the notice to proceed for phase 2. The contractor shall notify the contracting officer's representative when work is complete and all close out documents have been submitted. The contracting officer's representative shall have a maximum of 14 calendar days to review the submitted close out documents and, if all contractor requirements have been met, a notice to proceed will be provided for phase 4.

Phase 4:

a. Move occupants into newly renovated Building 302

The contractor does not need a notice to proceed to continue work for Phase 5.

Phase 5:

a. Move occupants out of Building 301 into fully prepared swing

SECTION 01 11 00 Page 3 spaces.

The contractor does not need a notice to proceed to continue work for Phase 6.

Phase 6:

a. Renovation of Building 301

b. Abatement of lead and asbestos materials in Building 301

c. Mechanical system shall be tested and balanced. Commissioning and verification shall be performed on mechanical systems as prescribed by specifications.

d. Complete electrical, security and communication systems are to be installed, verified and commissioned for building 301. The new electrical distribution system for 301 shall be fed from building 302.

e. Demolition of existing fire pump and fire tank and restoration of site.

f. Submission of close out documents

g. Government acceptance of renovated spaces

The contractor shall complete work in Phases 4, 5, and 6 within 360 calendar days from the notice to proceed for Phase 3. The contractor shall notify the contracting officer and contracting officer's representative when work is complete and all close out documents have been submitted. The contracting officer's representative shall have a maximum of 14 calendar days to review the submitted close out documents and, if all contractor requirements have been met, a notice to proceed will be provided for Phase 7.

Phase 7:

a. Move occupants into newly renovated Building 301.

b. Remove temporary trailers from flightline ramp.

c. Remove temporary utilities serving temporary trailers.

d. Clean up of Building 304 after occupants have moved out of swing space.

1.4.3.2 Fire Protection Phasing

The fire protection work was designed to maintain full fire protection of the occupied hangar bay throughout construction. The existing fire pumps, tank, and AFFF system will provide protection to Hangar 301 during phases 1 through 3. The new pumps, tanks, and HEF system will provide protection to Hangar 302 after phase 3. The new pumps, tanks, and HEF system will provide protection to Hangar 301 after phase 6. The existing fire alarm and foam releasing systems are to remain functional throughout construction until the new systems have been tested and accepted

SECTION 01 11 00 Page 4

1.4.3.3 Electrical Distribution Phasing

The electrical work has been design to allow for one hangar and the surrounding spaces to be fully functional and used by the Government at any given time. During phase 1 the new distribution system is to be installed in the new electrical room while the existing electrical system is still being utilized. Once the new electrical service is established the contractor shall temporarily relocate electrical feeds for Building 301 to the new service and build new distribution for Building 302. During Phases 2 through 3, Building 302 and will be fully functional, while building 301 is being renovated. During this renovation the temporary feeds for Building 301 will be demolished along with the existing distribution systems. The new distribution system for Building 301 is to be installed and feed from new service established in phase 1. During phase 4 the entire electrical distribution system shall be fully functional

1.4.3.4 Mechanical Phasing

The mechanical systems are designed to be a full replacement of the existing mechanical systems. The mechanical systems have been designed to allow for one hangar and the surrounding spaces to be fully functional and used by the Government at any given time. If any component of the HVAC systems that is required to be demolished or rendered nonfunctional during a particular phase of the project that will disrupt the service an occupied space, the contractor shall provide temporary HVAC to those spaces. The SIPRNET room shall be remain operational during the entire construction process. Temporary HVAC shall be provided to the SIPRNET area while work on Building 302 is being performed. Connections feeding Building 301 spaces that are constructed during the Building 302 phase shall be isolated by valves and capped during the renovation of Building 302 phase to allow for easy installation and change over.

1.4.3.5 LEED commissioning

LEED commissioning will be performed by a third-party consultant hired by the A-E.

1.4.3.6 Contractor Conditions During Project Phases

Contractor does not need to demobilize and re-mobilize between each phase

The contractor's bond shall remain effective through the construction period between the beginning of Phase 1 and the end of Phase 7.

Contractor shall erect temporary partition wall in all areas between building areas that are occupied and areas under construction. Temporary partition walls shall be used to contain dust., and debris within construction area and to protect occupied areas from construction activities. Temporary partition walls shall be constructed to the satisfaction of the COR.

1.4.4 Requirements for Moving Building Occupants and Items

The contractor is responsible for moving all existing items for building occupants throughout the project. This includes, but not limited to, furniture, equipment, and miscellaneous items placed in boxes by the Government. The contractor is not required to move computers, phones, and other items identified by the Government. Contractor shall quantify all materials to be moved during the pre-proposal walk through; this will be

SECTION 01 11 00 Page 5 the contractor's sole opportunity to quantify materials to be moved.

Larger equipment that shall be moved by the contractor is indicated on sheet G-112. This list is not a comprehensive list of equipment; however, it should be used as general guidance for moving equipment during each phase.

The contractor shall use a specialty subcontractor for all moving work.

This subcontractor shall have experience and appropriate equipment for large scale moving operations similar to what is required for this project.

Equipment that is indicated on sheet G-112 shall be inspected by the Government and the contractor before it is moved and after it is setup.

This inspection shall be documented on form located at the end of this specification section. This form will serve as documentation of the condition of the equipment before and after the move. The condition of the equipment for each move (i.e. from the original location to the swing space location and the swing space location to the final location) will be documented. These forms will be maintained by the Government and the contractor if desired. The contractor is responsible for all damage incurred by the moving operation.

1.4.5 Description of Telecommunications and Electronic Security System Work

There are several base networks that need to be maintained during the renovation of Buildings 301 and 302. If these networks go offline they will disrupt communications in other buildings across the base. Building 302 houses one of the four base Information Transfer Notes (ITN). This ITN is in an Inter-Switch Trunk (IST) configuration with building 310 ITN providing hot standby failover capability and load sharing for the Command Post and Ops Ground and bi-directional routing for the base LAN. Building 302 houses the Base Network Control Center (BNCC) which hosts the primary base share drive, the base file plan server, the HBSS scanner, the wireless network server and client servers such as digital dental, fire department and the OPS PEX server. Building 302 houses the SIPRNET server and the head end CATV system for the base.

All telecommunications work shall be furnished, installed, and tested by the contractor including cabling, connectors, outlets, racks, patch panels, patch cords, fiber and fiber patch panels, labeling and testing.

All cable trays, conduit, patch panels and related items shall be part of the base bid package. The purchase, installation, testing and labeling of all communications equipment and wiring shall be a separate line item "Bid Option".

1.4.6 Work with SIPRNET Area

Power and communication to SIPRNET area shall be fully functional throughout entire project. All work within the SIPRNET Area shall be coordinated with the Contracting Office's Representative. All work shall be observed by the base personnel. If base personnel is not present, no work shall be completed. Access to SIPRNET area will be strictly controlled by the Government throughout the duration of the project.

1.5 PROJECT ENVIRONMENTAL GOALS

Contractor shall distribute copies of the Environmental Goals to each subcontractor and the Contracting Officer. The overall goal for design, construction, and operation is to produce a building that meets the

SECTION 01 11 00 Page 6 functional program needs and incorporates the principles of sustainability. Specifically:

a. Preserve and restore the site ecosystem and biodiversity; avoid site degradation and erosion. Minimize offsite environmental impact.

b. Use the minimum amount of energy, water, and materials feasible to meet the design intent. Select energy and water efficient equipment and strategies.

c. Use environmentally preferable products and decrease toxicity level of materials used.

d. Use renewable energy and material resources.

e. Optimize operational performance (through commissioning efforts) in order to ensure energy efficient equipment operates as intended.

Consider the durability, maintainability, and flexibility of building systems.

f. Manage construction site and storage of materials to ensure no negative impact on the indoor environmental quality of the building.

g. Reduce construction waste through reuse, recycling, and supplier take-back.

1.6 EXISTING WORK

In addition to "FAR 52.236-9, Protection of Existing Vegetation, Structures, Equipment, Utilities, and Improvements":

a. Remove or alter existing work in such a manner as to prevent injury or damage to any portions of the existing work which remain.

b. Repair or replace portions of existing work which have been altered during construction operations to match existing or adjoining work, as approved by the Contracting Officer. At the completion of operations, existing work shall be in a condition equal to or better than that which existed before new work started.

1.7 ON-SITE PERMITS

1.7.1 Utility Outage Requests and Utility Connection Requests

Notify the Contracting Officer 's Representative at least 72 hours prior to starting excavation work. Contractor is responsible for marking and verifying all utilities not marked.

The Contractor shall verify the elevations of existing piping, utilities, and any type of underground obstruction not indicated or specified to be removed. But indicated in locations to be transversed by piping, ducts, and other work to be installed. Verify elevations before installing new work closer than nearest manhole or other structure at which an adjustment in grade can be made.

Work shall be scheduled to hold outages to a minimum.

Utility outages and connections required during the prosecution of work that affect existing systems shall be arranged for at the convenience of

SECTION 01 11 00 Page 7 the Government and shall be scheduled outside the regular working hours or on weekends.

Contracting Officer 's Representative may permit utility outages at his discretion.

Contractor shall not be entitled to additional payment for utility outages and connections required to be performed outside the regular work hours.

Requests for utility outages and connections shall be made in writing to the Contracting Officer 's Representative at least 14 calendar days in advance of the time required. Each request shall state the system involved, area involved, approximate duration of outage, and the nature of work involved.

1.7.2 Borrow, Excavation, Welding, and Burning Permits

ACTIVITY SUBMISSION DATE SUBMISSION FORM

Borrow Permits 15 calendar days prior to work

Coordinate with Base Civil Engineer

Burning Permits 15 calendar days prior to work

Coordinate with Base Civil Engineer

Excavation Permits 15 calendar days prior to work

Coordinate with Base Civil Engineer

Welding Permits 15 calendar days prior to work

Coordinate with Base Civil Engineer

Permits shall be posted at a conspicuous location in the construction area.

Burning of trash or rubbish is not permitted .

1.8 LOCATION OF UNDERGROUND UTILITIES

Obtain digging permits prior to start of excavation by contacting the Contracting Officer 's Representative 15 calendar days in advance . Scan the construction site with Ground Penetrating Radar and electromagnetic or sonic equipment, and mark the surface of the ground, where existing underground utilities or utilities encased in pier structures are discovered. Verify the elevations of existing piping, utilities,and any type of underground or encased obstruction not indicated to be specified or removed but indicated or discovered during scanning in locations to be traversed by piping, ducts, and other work to be conducted or installed.

Verify elevations before installing new work closer than nearest manhole or other structure at which an adjustment in grade can be made.

1.8.1 Notification Prior to Excavation

Notify the Contracting Officer 's Representative at least 15 days prior to starting excavation work.

SECTION 01 11 00 Page 8

1.9 SALVAGE MATERIAL AND EQUIPMENT

Items designated by the Contracting Officer to be salvaged shall remain the property of the Government.

The salvaged property shall be segregated, itemized, delivered, and off-loaded at the Government designated storage area located within 2 miles of the construction site. Soil and rocks must be separated prior to delivery to the storage area.

Contractor shall maintain property control records for material or equipment designated as salvage. Contractor's system of property control may be used if approved by the Contracting Officer. Contractor shall be responsible for storage and protection of salvaged materials and equipment until disposition by the Contracting Officer.

PART 2 PRODUCTS

Not used.

PART 3 EXECUTION

Not used.

-- End of Section --

SECTION 01 11 00 Page 9

SHOP/PERSONNEL -

WING

NOMENCLATURE

POND

NOMENCLATURE

QUANITY ITEM

BLDG./HGR

(CURRENT

LOCATION)

RM. #

(CURRENT

LOCATION)

EQUIPMENT

MOVED TO

Munitions MUNITIONS 4 EA.

DESKS (ONE WITH TOP

BOOKSHELF/FILE CABINET) 302 101 Trailer

Munitions MUNITIONS 1 EA.

FILE CABINET WITH TOP

BOOKSHELF 302 101 Trailer

Munitions MUNITIONS 1 EA. 100LB. SAFE 302 101 Trailer Munitions MUNITIONS 1 EA. SOFA 302 101 Trailer Munitions MUNITIONS 4 EA. CHAIRS 302 101 Trailer Munitions MUNITIONS 3 EA. LOCKERS 302 101 Trailer Munitions MUNITIONS 1 EA. WALL MOUNTED CUPBOARD 302 101 Trailer Munitions MUNITIONS 1 EA. TV 302 101 Trailer Munitions MUNITIONS 1 EA. TV STAND 302 101 Trailer Munitions MUNITIONS 1 EA. PRINTER 302 101 Trailer Munitions MUNITIONS 1 EA. SHREDDER 302 101 Trailer Munitions MUNITIONS 3 EA. COMPUTERS 302 101 Trailer Munitions MUNITIONS 3 EA. NOTEBOOKS 302 101 Trailer Munitions MUNITIONS 1 EA. COAT RACK 302 101 Trailer Munitions MUNITIONS 2 EA. TRASH CANS 302 101 Trailer Munitions MUNITIONS 1 EA. MICROWAVE 302 101 Trailer Munitions MUNITIONS 1 EA. MICROWAVE STAND 302 101 Trailer Munitions MUNITIONS 1 EA. RECYCLING BIN 302 101 Trailer

Flightline MX FLIGHTLINE 1 EA. MAIL CENTER

146 (TOOL

ROOM) 304

Flightline MX FLIGHTLINE 5 EA. PELICAN BOXES

146 (TOOL

ROOM) 304

Flightline MX FLIGHTLINE 7 EA. TOOL BOXES

146 (TOOL

ROOM) 304

Flightline MX FLIGHTLINE 7 EA. SHELVING UNITS

146 (TOOL

ROOM) 304

Flightline MX FLIGHTLINE 4 EA. 4'X8' PPE BOARDS

146 (TOOL

ROOM) 304

Flightline MX FLIGHTLINE 4 EA. LOCKERS ( 3 FLAMMABLE 1 PMEL)

146 (TOOL

ROOM) 304

Flightline MX FLIGHTLINE 2 EA. SHADOW BOARDS

146 (TOOL

ROOM) 304

Flightline MX FLIGHTLINE 1 EA. DESK

146A ( TOOL

ROOM OFFICE) 304

Flightline MX FLIGHTLINE 1 EA. PRINTER

146A ( TOOL

ROOM OFFICE) 304

Flightline MX FLIGHTLINE 2 EA. FILING CABINET

146A ( TOOL

ROOM OFFICE) 304

Flightline MX FLIGHTLINE 1 EA. COMM STORAGE CABINET

146A ( TOOL

ROOM OFFICE) 304

Flightline MX FLIGHTLINE 6EA. COMPUTER DESKS

147 ( FLIGHT

LINE OFFICE) 304

Flightline MX FLIGHTLINE 1 EA. COPIER

147 ( FLIGHT

LINE OFFICE) 304

Flightline MX FLIGHTLINE 1 EA. FAX

147 ( FLIGHT

LINE OFFICE) 304

Flightline MX FLIGHTLINE 1 EA. PRINTER

147 ( FLIGHT

LINE OFFICE) 304

Flightline MX FLIGHTLINE 1 EA. SHREDDER

147 ( FLIGHT

LINE OFFICE) 304

Flightline MX FLIGHTLINE 1 EA. REFRIGERATOR

147 ( FLIGHT

LINE OFFICE) 304

Flightline MX FLIGHTLINE 2 EA. FILING CABINETS

147 ( FLIGHT

LINE OFFICE) 304

Flightline MX FLIGHTLINE 1 EA. BOOK SHELF

147 ( FLIGHT

LINE OFFICE) 304

Flightline MX FLIGHTLINE 1 EA. DRY ERASE BOARD

147 ( FLIGHT

LINE OFFICE) 304

Flightline MX FLIGHTLINE 2 EA. BULLETIN BOARDS

147 ( FLIGHT

LINE OFFICE) 304

Flightline MX FLIGHTLINE 7 EA. PERSONAL LOCKERS

148 ( FLIGHT

LINE OFFICE

PERSONNEL) 304

Flightline MX FLIGHTLINE 6 EA. PERSONAL LOCKERS

151 ( WOMENS

LATRINE) 304

Flightline MX FLIGHTLINE 3 EA. REFRIGERATORS

153 ( FLIGHT

LINE BREAK

ROOM) 304

Flightline MX FLIGHTLINE 6 EA. COUCHES

153 ( FLIGHT

LINE BREAK

ROOM) 304

Flightline MX FLIGHTLINE 46 EA. CHAIRS

153 ( FLIGHT

LINE BREAK

ROOM) 304

Flightline MX FLIGHTLINE 1 EA. COFFEE MAKER

153 ( FLIGHT

LINE BREAK

ROOM) 304

Flightline MX FLIGHTLINE 4 EA. MICROWAVES

153 ( FLIGHT

LINE BREAK

ROOM) 304

Flightline MX FLIGHTLINE 1 EA. COFFEE FUND LOCKER

153 ( FLIGHT

LINE BREAK

ROOM) 304

Flightline MX FLIGHTLINE 1 EA. POP MACHINE

153 ( FLIGHT

LINE BREAK

ROOM) 304

Flightline MX FLIGHTLINE 1 EA. CANDY MACHINE

153 ( FLIGHT

LINE BREAK

ROOM) 304

Flightline MX FLIGHTLINE 1 EA. TELEVISION

153 ( FLIGHT

LINE BREAK

ROOM) 304

Flightline MX FLIGHTLINE 1 EA. TOASTER

153 ( FLIGHT

LINE BREAK

ROOM) 304

Flightline MX FLIGHTLINE 1 EA. TOASTER OVEN

153 ( FLIGHT

LINE BREAK

ROOM) 304

Flightline MX FLIGHTLINE 1 EA. AIRCRAFT STATUS/TRIP BOARD

153 ( FLIGHT

LINE BREAK

ROOM) 304

Flightline MX FLIGHTLINE 1 EA. SAFETY BOARD

153 ( FLIGHT

LINE BREAK

ROOM) 304

Flightline MX FLIGHTLINE 6 EA. COMPUTER STATIONS

155 (COMPUTER

ROOM) 304

Flightline MX FLIGHTLINE 2 EA. PRINTERS

155 (COMPUTER

ROOM) 304

Flightline MX FLIGHTLINE 1 EA. SHREDDER

155 (COMPUTER

ROOM) 304

Flightline MX FLIGHTLINE 1 EA. 2 DRAWER FILING CABINET

155 (COMPUTER

ROOM) 304

Flightline MX FLIGHTLINE 1 EA. CREDENSA'

155 (COMPUTER

ROOM) 304

Flightline MX FLIGHTLINE 9 EA. CHAIRS

155 (COMPUTER

ROOM) 304

Flightline MX FLIGHTLINE 1 EA. DRY ERASE BOARD

155 (COMPUTER

ROOM) 304

Flightline MX FLIGHTLINE 1 EA. BULLETIN BOARD

155 (COMPUTER

ROOM) 304

Flightline MX FLIGHTLINE 48 EA. PERSONAL LOCKERS

156 ( FLIGHT

LINE LOCKER

ROOM) 304

Flightline MX FLIGHTLINE 6 EA. 18 PERSON PPE LOCKERS 157 304

Flightline MX FLIGHTLINE 65 EA. PERSONAL LOCKERS

247 (UPSTAIRS

LOCKER ROOM) 304

Flightline MX FLIGHTLINE 12 EA. BENCHES

247 (UPSTAIRS

LOCKER ROOM) 304

Flightline MX FLIGHTLINE 1 EA. TAIL NUMBER BIN UNIT 302 153 (OUTSIDE) 304 Flightline MX FLIGHTLINE 1 EA. FLAMMABLE LOCKER 302 146 (OUTSIDE) 304 Flightline MX FLIGHTLINE 2 EA. FLAMMABLE LOCKERS 302 153 (OUTSIDE) 304 Flightline MX FLIGHTLINE 3 EA. TELEVISIONS 146, 147, 153 DRMO Flightline MX FLIGHTLINE 2 EA. BULLETIN BOARDS 147 DRMO

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. DESKS 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. ORGANIZERS 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. COMPUTERS 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 4 EA. MONITORS 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. KEYBOARDS 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. MOUSES 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. LAPTOP 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. CHAIRS 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. TV 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. SMALL REFRIGERATOR 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. PHONES 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. MICROWAVE 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. H20 DISPENSER 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. PAPER SHREDDER 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. PRINTER 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. SHELVING UNIT 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. TOP HALF SHELVING UNITS 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. LOCKERS 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. GARBAGE CANS 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) ?

MULTIPLE BINDERS OF ACFT

HISTORY 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) ?

MULTIPLE MX PERFORMANCE

BINDERS 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 6 EA. BOXES OF SUPPLIES 302 235 Trailer

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. COMPUTERS 302 235 Storage

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 3 EA. MONITORS 302 235 Storage

MOF Analysis

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 4 EA. SMALL FILING CABINETS 302 235 Storage

MOF Support/OIC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. WORKSTATION 302 238 Trailer

MOF Support/OIC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. DESK 302 238 Trailer

MOF Support/OIC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. COMPUTERS 302 238 Trailer

MOF Support/OIC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 4 EA. MONITORS 302 238 Trailer

MOF Support/OIC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 3 EA. CHAIRS 302 238 Trailer

MOF Support/OIC

MAINTENANCE

FLIGHT (MOF) 1 EA. TV 302 238 Trailer

MOF Support/OIC

OPERATIONS

FLIGHT (MOF) 1 EA. FILE CABINET 302 238 Trailer

MOF Support/OIC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. LOCKERS 302 238 Trailer

MOF Support/OIC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. SMALL TABLE 302 238 Trailer

MOF Support/OIC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 8 EA. LARGE BOXES 302 238 Storage

MOF P&S

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 3 EA. DESKS 302 236 Trailer

MOF P&S

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 3 EA. COMPUTERS 302 236 Trailer

MOF P&S

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 6 EA. CHAIRS 302 236 Trailer

MOF P&S

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 3 EA. PHONES(7322)(7399)(7304) 302 236 Trailer

MOF P&S

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. TABLE 302 236 Trailer

MOF P&S

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA.

WHOLE FILE PLAN-CABINETS BY

MOC DOOR/BEHIND DESK 302 236 Trailer

MOF P&S

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. TV 302 236 Trailer

MOF P&S

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. COPIER 302 236 Trailer

MOF P&S

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. PRINTER AND IT'S SHELF 302 236 Trailer

MOF P&S

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. SHREDDER 302 236 Trailer

MOF P&S

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 4 EA.

LOCKERS FROM THE LOCKER

ROOM 302 236 Trailer

MOF P&S

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. LOCKER/CABINET TV IS ON 302 236 Trailer

MOF P&S

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. REFRIDGERATOR 302 236 Trailer

MOF RA

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. WORKSTATIONS 301 205 Trailer

MOF RA

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. FILING CABINETS 301 205 Trailer

MOF RA

MAINTENANCE

FLIGHT (MOF) 1 EA. LOCKER 301 205 Trailer

MOF RA

OPERATIONS

FLIGHT (MOF) 4 EA. CHAIRS 301 205 Trailer

MOF RA

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. COMPUTERS/MONITORS 301 205 Trailer

MOF RA

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 6 EA. LARGE BOXES 301 205 Trailer

MOF RA

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. REFRIGERATOR 301 205 Trailer

MOC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 3 EA. WORK STATIONS (DESKS) 302 237 Trailer

MOC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 5 EA. COMPUTERS 302 237 Trailer

MOC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 7 EA. MONITORS 302 237 Trailer

MOC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA.

BACK UP BATTERY FOR

COMPUTERS 302 237 Trailer

MOC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 6 EA. CHAIRS 302 237 Trailer

MOC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. PLASMA TV 302 237 Trailer

MOC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. CREDENZA 302 237 Trailer

MOC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 9 EA. LOCKERS 302 237 Trailer

MOC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. PRINTER 302 237 Trailer

MOC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. TABLE FOR PRINTER 302 237 Trailer

MOC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 4 EA.

PHONES TO INCLUDE THE STE

AND CRASH NET 302 237 Trailer

MOC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. UHF RADIO/SPEAKERS 302 237 Trailer

MOC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. TABLE FOR UHF RADIO 302 237 Trailer

MOC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. GARBAGE CANS 302 237 Trailer

MOC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 1 EA. STORAGE CREDENZA 302 237 Trailer

MOC

MAINTENANCE

FLIGHT (MOF) 25 EA. BINDERS/CHECKLIST 302 237 Trailer

MOC

OPERATIONS

FLIGHT (MOF) 1 EA. SHELTER IN PLACE SUPPLIES 302 237 Trailer

MOC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA.

LARGE BOXES FOR MISC STUFF

(pens, personal items) 302 237 Trailer

MOC

MAINTENANCE

OPERATIONS

FLIGHT (MOF) 2 EA. LARGE BOXES 302 237 Storage

Structural -Decal Room Equip. DECAL ROOM 1 EA. DECAL ROOM EQUIPMENT 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. PPE STORAGE LOCKERS 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. DECAL VIDMAR 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. TRAINING RECORD CABINET 302 162 304 Structural -Decal Room Equip. DECAL ROOM 2 EA. GERBER SUPPLY CABINET 302 162 304 Structural -Decal Room Equip. DECAL ROOM 2 EA. DECAL STORAGE DRAWER UNIT 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. GERBER PLOTTER, LARGE 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. GERBER PRINTER, LARGE 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. GERBER PRINTER, SMALL 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. GERBER PLOTTER, SMALL 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA.

GERBER PC & MONITOR &

SCANNER 302 162 304

Structural -Decal Room Equip. DECAL ROOM 1 EA. GERBER WORKSTATION DESK 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. GERBER EQUIPMENT TABLE 302 162 304 Structural -Decal Room Equip. DECAL ROOM 2 EA. DECAL PREP TABLES 302 162 304 Structural -Decal Room Equip. DECAL ROOM 2 EA. DECAL STORAGE WALL UNIT 302 162 304 Structural -Decal Room Equip. DECAL ROOM 3 EA.

COLD WEATHER GEAR STORAGE

UNIT 302 162 304

Structural -Decal Room Equip. DECAL ROOM 1 EA.

PPE CLEANING EQUIPMENT &

SHELF 302 162 304

Structural -Decal Room Equip. DECAL ROOM 5 EA. NETWORK PC & MONITOR 302 162 304 Structural -Decal Room Equip. DECAL ROOM 2 EA. NETWORK PRINTER 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. SMCO OFFICE EQUIPMENT 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. SHREDDER 302 162 304 Structural -Decal Room Equip. DECAL ROOM 2 EA. FILE CABINET (Supervisor) 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. BOOKSHELF (Supervisor) 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. SUPERVISOR OFFICE FURNITURE 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. STORAGE LOCKER 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. WATER COOLER UNIT 302 162 304

Structural -Decal Room Equip. DECAL ROOM 1 EA. REFRIDGERATOR 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. POP MACHINE 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA.

TRAINING VIDEO STORAGE

CABINET 302 162 304

Structural -Decal Room Equip. DECAL ROOM 1 EA. TV & DVD/VCR 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA.

SHOP EQUIPMENT AND TOOLING

CATALOGS (5bxs) 302 162 304

Structural -Decal Room Equip. DECAL ROOM 1 EA. CLEANING SUPPLY LOCKER 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. PPE STORAGE LOCKERS 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. DECAL VIDMAR 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. TRAINING RECORD CABINET 302 162 304 Structural -Decal Room Equip. DECAL ROOM 2 EA. GERBER SUPPLY CABINET 302 162 304 Structural -Decal Room Equip. DECAL ROOM 2 EA. DECAL STORAGE DRAWER UNIT 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. GERBER PLOTTER, LARGE-110V 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. GERBER PRINTER, LARGE 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. GERBER PRINTER, SMALL-110V 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. GERBER PLOTTER, SMALL-110V 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA.

GERBER PC & MONITOR &

SCANNER-110V 302 162 304

Structural -Decal Room Equip. DECAL ROOM 1 EA. GERBER WORKSTATION DESK 302 162 304 Structural -Decal Room Equip. DECAL ROOM 1 EA. GERBER EQUIPMENT TABLE 302 162 304 Structural -Decal Room Equip. DECAL ROOM 2 EA. DECAL PREP TABLES 302 162 304 Structural -Decal Room Equip. DECAL ROOM 2 EA. DECAL STORAGE WALL UNIT 302 162 304 Structural -Decal Room Equip. DECAL ROOM 3 EA.

COLD WEATHER GEAR STORAGE

UNIT 302 162 304

Structural -Decal Room Equip. DECAL ROOM 1 EA.

PPE CLEANING EQUIPMENT &

SHELF 302 162 304

Structural -Decal Room Equip. DECAL ROOM 5 EA. NETWORK PC & MONITOR-110V 302 162 304 Structural -Decal Room Equip. DECAL ROOM 2 EA. NETWORK PRINTER-110V 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. SANDER-208V&AIR 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. DRILL PRESS-220V 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 5 EA. VACUUMS-110V 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. ENGLISH WHEEL 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. NOTCHER 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. FOOTSHEAR 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. POWERSHEAR-230V 3 PHASE 302 162 304

Shop Equip. METAL SHOP 1 EA.

TUBING BENDER W/TOOLING

VIDMAR 302 162 304

Structural -SMCO Shop Equip. METAL SHOP 1 EA. GRINDER-110V 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. MINI SANDER-110V 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. ROTEX PUNCH 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA.

TUBING FLARING MACHINE-440V

3 PHASE & AIR 302 162 304

Structural -SMCO Shop Equip. METAL SHOP 1 EA. BAND SAW-230V 3 PHASE 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. SM-15 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. DIMPLER-110V & AIR 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. SLIP ROLLER 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. SHRINKER 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. STRETCHER 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. BAR FOLDER 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. SM-12 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. SM-13 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 2 EA. VISE & PEDESTAL 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. SM-25 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 2 EA. WORK TABLES 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. HAZ MAT CABINET 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. TOOL LOCKER 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. CHEMICAL REFRIDGERATOR-110V 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. SHOP SUPPLY VIDMAR 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. SHOP EQUIPMENT CABINET 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. TC MAX PC & MONITOR-110V 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. SM-10 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. LMR STATION 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. FLASHLIGHT BANK-110V 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA.

DRILL BATTERY BANK (11 PCS)-

110V 302 162 304

Structural -SMCO Shop Equip. METAL SHOP 1 EA. SHOP / BENCH STOCK VIDMARS 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 3 EA. BAG ROLL HOLDERS 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. HAZ CHEMICAL LOCKER 302 162 304

Shop Equip. METAL SHOP 1 EA. BOX & PAN BRAKE 302 162 304

Shop Equip. METAL SHOP 2 EA. WYPALL HOLDER 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. PPE CLEANING CABINET 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. SAFETY MIRROR 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 2 EA. SCRAP METAL BARREL 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. METAL STORAGE VIDMAR 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. BROOM RACK 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. LO/TO BOARD 302 162 304 Structural -SMCO Shop Equip. METAL SHOP 1 EA. RECYCLE BATTERY BOX 302 162 304 Structural -SMCO Office Equip. METAL SHOP 1 EA. SHREDDER 302 162 304 Structural -SMCO Office Equip. METAL SHOP 1 EA. FILE CABINET (Supervisor) (2ea) 302 162 304 Structural -SMCO Office Equip. METAL SHOP 1 EA. BOOKSHELF (Supervisor) 302 162 304 Structural -SMCO Office Equip. METAL SHOP 1 EA. SUPERVISOR OFFICE FURNITURE 302 162 304 Structural -SMCO Office Equip. METAL SHOP 1 EA. STORAGE LOCKER 302 162 304 Structural -SMCO Office Equip. METAL SHOP 1 EA. WATER COOLER UNIT-110V 302 162 304 Structural -SMCO Office Equip. METAL SHOP 1 EA. REFRIDGERATOR-110V 302 162 304 Structural -SMCO Office Equip. METAL SHOP 1 EA. POP MACHINE-110V 302 162 304 Structural -SMCO Office Equip. METAL SHOP 1 EA.

TRAINING VIDEO STORAGE

CABINET 302 162 304

Structural -SMCO Office Equip. METAL SHOP 1 EA. TV & DVD/VCR-110V 302 162 304 Structural -SMCO Office Equip. METAL SHOP 1 EA.

SHOP EQUIPMENT AND TOOLING

CATALOGS (5bxs) 302 162 304

Structural -SMCO Office Equip. METAL SHOP 1 EA. CLEANING SUPPLY LOCKER 302 162 304 Structural -SMCO Equip Hangar 302. METAL SHOP 2 EA.

CHEM BAG AND SUPPLY LOCKERS

(from hangar) 302 162 304

Structural -SMCO Equip Hangar 302. METAL SHOP 1 EA. METAL STORAGE RACK 302 162 304 Structural -SMCO Equip Hangar 302. METAL SHOP 1 EA. MOPS & BUCKETS 302 162 304 Structural -SMCO Equip Hangar 302. METAL SHOP 1 EA. HOT BONDER 302 162 304 Structural -SMCO Equip Hangar 302. METAL SHOP 1 EA. CLAYTON VACUUM 302 162 304 Structural -SMCO Equip Hangar 302. METAL SHOP 1 EA. COMPOSITE MATERIAL RACK 302 162 304 Structural -SMCO Equip Hangar 302. METAL SHOP 1 EA. SHOP STOCK OVERFLOW VIDMAR 302 162 304 Structural -SMCO Equip Hangar 302. METAL SHOP 1 EA. TUBING STORAGE 302 162 304 Structural -SMCO Equip Hangar 302. METAL SHOP 1 EA. SM-6 302 162 304 Structural -SMCO Equip Hangar 302. METAL SHOP 1 EA. SM-8 302 162 304

Equip Hangar 302. METAL SHOP 1 EA. CAGE 302 162 304

Equip Hangar 302. METAL SHOP 1 EA. WEIGHT & BALANCE FIXTURE 302 162 304 Structural -SMCO Equip Hangar 302. METAL SHOP 1 EA.

ACCURPRESS MACHINE-208V 3

PHASE 302 162 304

Electrical Environmental E&E 1 EA. VIDMAR, BENCH STOCK 302 139 Engine Shop Electrical Environmental E&E 1 EA. VIDMAR, OXYGEN BENCH STOCK 302 139 Engine Shop Electrical Environmental E&E 1 EA. VIDMAR, WORK ORDER RESIDUE 302 139 Engine Shop Electrical Environmental E&E 1 EA. VIDMAR, IN-SHOP TOOLBOX 302 139 Engine Shop Electrical Environmental E&E 1 EA. LOCKER, WIRE SUPPLIES 302 139 Engine Shop Electrical Environmental E&E 1 EA. LOCKER, TAIL NUMBER BIN 302 139 Engine Shop Electrical Environmental E&E 1 EA. LOCKER, SQUIB 302 139 Engine Shop Electrical Environmental E&E 1 EA.

WORKBENCH, LARGE, W/

ATTACHED VISE 302 139 Engine Shop

Electrical Environmental E&E 2 EA. WORKBENCH, LARGE 302 139 Engine Shop Electrical Environmental E&E 1 EA. WORKBENCH, SMALL 302 139 Engine Shop Electrical Environmental E&E 1 EA. SOLDER STATION 302 139 Engine Shop Electrical Environmental E&E 1 EA. CTK STORAGE RACK 302 139 Engine Shop Electrical Environmental E&E 3 EA. MINI CTKS (DISPATCHABLE) 302 139 Engine Shop Electrical Environmental E&E 1 EA. OXYGEN MAINTENANCE CTK 302 139 Engine Shop Electrical Environmental E&E 1 EA. IDG/ACM CTK 302 139 Engine Shop Electrical Environmental E&E 2 EA. MULTIMETER KITS 302 139 Engine Shop Electrical Environmental E&E 1 EA. HEATING TOOLKIT 302 139 Engine Shop Electrical Environmental E&E 1 EA.

HEATING TOOLKIT RECHARGER

KIT 302 139 Engine Shop

Electrical Environmental E&E 1 EA. WIRE MAINTENANCE KIT 302 139 Engine Shop Electrical Environmental E&E 1 EA. CTK KEY LOCKBOX 302 139 Engine Shop Electrical Environmental E&E 8 EA.

SHOP COMPUTERS (2 DESKTOP, 6

LAPTOP/ETOOL) 302 139 Engine Shop

Electrical Environmental E&E 1 EA.

PPE STORAGE (CURRENTLY A

WALL MOUNTED BOARD) 302 139 Engine Shop

Electrical Environmental E&E 2 EA.

BATTERY CHARGERS,

DEPLOYMENT PACKED/ROTATING

USAGE 302 139 Engine Shop

Electrical Environmental E&E 3 EA.

220VAC, 3 PRONG

ROTATING/LOCKING

RECEPTACLES (TAKE FROM OLD

BATTERY SHOP) 302 139 Engine Shop

Electrical Environmental E&E 1 EA. PERSONAL GEAR LOCKER 302 138 Engine Shop Electrical Environmental E&E 3 EA.

BATTERY CHARGERS, SET UP FOR

USAGE 302 140 Engine Shop

Electrical Environmental E&E 2 EA.

BATTERY CHARGERS,

DEPLOYMENT PACKED/ROTATING

USAGE 302 140 Engine Shop

Electrical Environmental E&E 3 EA.

220VAC, 3 PRONG

ROTATING/LOCKING

RECEPTACLES (TAKE FROM OLD

BATTERY SHOP) 302 140 Engine Shop

Electrical Environmental E&E 1 EA.

CHEMICAL STORAGE FIRE LOCKER

(REQUIRES STATIC GROUNDING) 302 140 Engine Shop

Electrical Environmental E&E 1 EA. BOTTLE SERVICING STAND 302 126 Engine Shop Electrical Environmental E&E 1 EA. BOTTLE STORAGE RACK 302 126 Engine Shop Electrical Environmental E&E 1 EA.

VIDMAR, BOTTLE MAINTENANCE

TOOLS 302 126 Engine Shop

Electrical Environmental E&E 1 EA. AIR VISE, BOTTLE 302 126 Engine Shop Electrical Environmental E&E 1 EA. C02 BOTTLE CRADLE ASSEMBLY 302 126 Engine Shop Electrical Environmental E&E 1 EA. C02 BOTTLE STORAGE RACK 302 126 Engine Shop Electrical Environmental E&E 1 EA.

CHEMICAL GEAR STORAGE (ROLL

AWAY BIN) 302 126 Engine Shop

Electrical Environmental E&E 1 EA. DESK 302 138A Engine Shop Electrical Environmental E&E 1 EA.

COMPUTER STAND

W/COMPUTER AND PRINTER 302 138A Engine Shop

Electrical Environmental E&E 1 EA. OFFICE SUPPLY LOCKER 302 138A Engine Shop Electrical Environmental E&E 1 EA.

PERSONAL RECORDS FILE

CABINET 302 138A Engine Shop

Electrical Environmental E&E 1 EA.

IPAD STORAGE/CHARGING

CABINET 302 138A Engine Shop

Electrical Environmental E&E 2 EA.

This is the start of the file's text. The full file is on GovTribe.