INTERLOCKING T-WALL 12FT.pdf

PDF 276 KB Posted

Attached to
laska Barrier Purchase
Solicitation number
W912HZ25Q5940
Issued by

About this file

This image is a technical engineering drawing for an Interlocking T-Wall design, specifically detailing multiple wall types (Types 1-7A/7B) with precise dimensional specifications for lifting eyes and bar configurations. The plan and section views provide detailed schematics showing structural variations, with annotations highlighting key design notes such as:

  1. Minimum 4 cm (1½") clear cover
  2. Counter mobility cable anchorage that can also serve as a lifting eye
  3. A comprehensive table indicating development lengths for #8 bar lifting eyes, with variations for straight and hooked configurations across different lengths (3000-5000 mm) and different bar/eye combinations. The drawing is part of a U.S. Army Corps of Engineers contract opportunity (Solicitation Number W912HZ25Q5940) for barrier purchase, specifically targeting concrete product manufacturing with a small business set-aside.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RDGSLOEM

Polygon Change with a Meadow Burke 8-Ton DB-53 MB Dogbone Eye Anchor and 8-Ton DB-60 #6 Grade 60 rebar.

RDGSLOEM

Polygon See comment for Type 5 above.