INTERLOCKING T-WALL 12FT.pdf
PDF 276 KB Posted
- Attached to
- laska Barrier Purchase
- Solicitation number
- W912HZ25Q5940
About this file
This image is a technical engineering drawing for an Interlocking T-Wall design, specifically detailing multiple wall types (Types 1-7A/7B) with precise dimensional specifications for lifting eyes and bar configurations. The plan and section views provide detailed schematics showing structural variations, with annotations highlighting key design notes such as:
- Minimum 4 cm (1½") clear cover
- Counter mobility cable anchorage that can also serve as a lifting eye
- A comprehensive table indicating development lengths for #8 bar lifting eyes, with variations for straight and hooked configurations across different lengths (3000-5000 mm) and different bar/eye combinations. The drawing is part of a U.S. Army Corps of Engineers contract opportunity (Solicitation Number W912HZ25Q5940) for barrier purchase, specifically targeting concrete product manufacturing with a small business set-aside.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RDGSLOEM
Polygon Change with a Meadow Burke 8-Ton DB-53 MB Dogbone Eye Anchor and 8-Ton DB-60 #6 Grade 60 rebar.
RDGSLOEM
Polygon See comment for Type 5 above.