This technical drawing is a detailed engineering plan for security fence posts and cable anchorage structures, prepared by the US Army Corps of Engineers. The document (Identification Number C1-02) provides comprehensive architectural specifications for seven different post types (Type 1-7), including plan, section, and elevation views. Key technical details include:
The drawing specifies precise dimensional measurements for each post type, reinforcement configurations, and structural components. Notable specifications include a minimum 4 cm clear cover, counter mobility cable anchorage that can also function as a lifting eye, and a development length table for #8 bar lifting eyes with varying straight and hooked configurations. The technical drawing includes precise measurements in both imperial and metric units, with specific notes about main reinforcement positioning and structural requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C
E
I
I
I
:i:7 0.3m 0.24m
11718 " _:\_97/16"7.
0.3m
117/8
� I /�� 0.3m I " I�-!<----+-+
11718"-"' 7
15 DIA. @20 cm O.C. (#4 @8" O.C.J
I'\. o.am ! � J Lo.��
0.16m 97/18" 65/16"
PLAN
,,r- 25 DIA. (#8) LIFTING EYE
V (TYPES)
� I=::. � 15 DIA @20cm O.C. (#4@8" O.C.)
(TYPE4)
�15DIA.@20 cmO.C. (#4@8"0.C.)
(TYPE6)
� i /
(TYPE 1)
,,,,,,-1s □1A.@20cmO.C (#4@8"0.C.)
(TYPES)
I
_, __ riJ '"'I ---.,.,;
m --l � � 2'-10 1/2 " d It)
TYPE2
1. 1.39m
4'-63/4 " .1
TYPE 1
CABLEANCORAGE
(NOTE2)
I
I
I
I
I
I
I
I
I
I
I
I
I
I r�,·�-
SECURITY FENCE POST
£1.38m 1' f 15/18" u I
I
I
I
I
I
I
I I
I
I
I
I
I
I
25 DIA. (#8 BAR) CABLE ANCHORAGE (NOTE 2)
15DIA.@20�-�-
(#4@
"'1'
8"
0.
C )
_ \-;,l,I'/
TYPE
) \N ;'$..-E���l �: �JE�
0�
15 DIA. @20 cm O.C. (#4 @8" O.C.)
(TYPE 2)
SECTION
I
4'-113/16"
ELEVATION
I
I
TYPE4
TYPES
h E •
I
I
0.48m
TYPE6 TYPE ?A
NOTES
0.48m
, ,•-e314•
I
0.4m I 1'-3 3}4"
TYPE 78
1. MAIN REINFORCEMENT NOT SHOWN IN PLAN
AND ELEVATION FOR CLARITY.
2. COUNTER MOBILITY CABLE ANCHORAGE
THAT CAN ALSO BE USED AS A LIFTING EYE .
3. MINIMUM 4 cm (1 1/2") CLEAR COVER.
4. SEE TABLE FOR Le VALUES.
I m
US ARMY CORPS
OF ENGINEERS
a:
w ii:
f z wen i5 :::!
�ffi �Cl
QO
a:z <C <C o en zz
� :s en o..
IDENTIFICATION
NUMBER
C1-02