Asbestos_Floor_Tile_Report_671_Break_room_26_May_16.pdf
PDF 161 KB Posted
- Attached to
- Upgrade Breakroom 671
- Solicitation number
- W912GY16T0035
About this file
Asbestos Floor Tile Report
View the file
Other files
| File | Type | Posted |
|---|---|---|
| BLDG_671_BREAKROOM_CABINET.pdf | ||
| Questions_and_Answers_Set_5.doc | DOC document | |
| QUESTIONS_AND_ANSWERS_SET_4.doc | DOC document | |
| Epoxy_Broadcast_Floor_Coating_system.doc | DOC document | |
| Site_Visit_Sign_In_Sheet.pdf | ||
| Questions_and_Answers_Set_3.doc | DOC document | |
| Questions_and_Answers_Set_2.doc | DOC document | |
| Questions_and_Answers_Set_1.doc | DOC document | |
| Asbestos_Survey.pdf | ||
| Amendment_0001.pdf | ||
| W912GY-16-T-0035.pdf | ||
| Drawing_-_671_Breakroom_Cabinet.pdf |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Report No.
ASBESTOS TEM LABORATORIES, INC.
Analytical Report Polarized Light Microscopy
1350 Freeport Blvd., Unit 104 Sparks, NV 89431
(775) 359-3377
FAX (775) 359-2798
630 Bancroft Way, Berkeley, CA 94710 Ph. (510) 704-8930 Fax (510) 704-8929
With Main Office Located At:
EPA Method 600/R-93/116
131144
ASBESTOS TEM LABORATORIES, INC
Enclosed please find the bulk material analytical results for one or more samples submitted for asbestos analysis.
The analyses were performed in accordance with EPA Method 600/R-93/116 or 600/M4-82-020 for the determination of asbestos in bulk building materials by polarized light microscopy (PLM). Please note that while PLM analysis is commonly performed on non-friable and fine grained materials such as floor tiles and dust, the EPA method recognizes that PLM is subject to limitations. In these situations, accurate results may only be obtainable through the use of more sophisticated and accurate techniques such as transmission electron microscopy (TEM) or X-ray diffraction (XRD).
Prior to analysis, samples are logged-in and all data pertinent to the sample recorded. The samples are checked for damage or disruption of any chain-of-custody seals. A unique laboratory ID number is assigned to each sample. A hard copy log-in sheet containing all pertinent information concerning the sample is generated. This and all other relevant paper work are kept with the sample throughout the analytical procedures to assure proper analysis.
Each sample is opened in a class 100 HEPA negative air hood. A representative sampling of the material is selected and placed onto a glass microscope slide containing a drop of refractive index oil. The glass slide is placed under a polarizing light microscope where standard mineralogical techniques are used to analyze and quantify the various materials present, including asbestos. The data is then compiled into standard report format and subjected to a thorough quality assurance check before the information is released to the client.
Please note all samples will be held for 3 months from the date of receipt unless otherwise requested by client.
Sincerely Yours, Laboratory Analyst
ASBESTOS TEM LABORATORIES, INC.
--- These results relate only to the samples tested and must not be reproduced, except in full, with the approval of the laboratory. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. ---
Mr. Douglas Vittitow
LABORATORY JOB No.
Bldg 671 Breakroom Floor 1Polarized light microscopy analytical results for bulk sample(s) with
Job Site:
Job No.:
RE: 1 sample split(s)
Sierra Army Depot - DPW Bldg 75 'C' Street Herlong, CA 96113
May-26-16
With Main Office in Berkeley, CA (510) 704-8930
Report No.: 131144
1350 Freeport Blvd. Unit 104 . ..Sparks, NV 89431 (775) 359-3377 FAX (775) 359-2798
NVLAP Lab Code 200104-0
LAB
Bldg 75 'C' Street Herlong, CA 96113
Sierra Army Depot - DPW
EPA Method 600/R-93/116 or 600/M4-82-020
POLARIZED LIGHT MICROSCOPY
ANALYTICAL REPORT
Contact:
Address:
Job Site / No.
% TYPE
Laboratory Analyst
Samples Indicated:
Reg. Samples Analyzed:
ASBESTOS
OTHER DATA
SAMPLE ID FIELD
Lab ID #
Lab ID #
Lab ID #
Lab ID #
Lab ID #
Lab ID #
Lab ID #
Lab ID #
Lab ID #
Lab ID #
Date Submitted:
Date Reported:
Bldg 671 Breakroom Floor
May-24-16 May-26-16
Mr. Douglas Vittitow
131144Report No.
834-00065-001A
1. 1-5% Chrysotile None Detected 95-99% Plast, Calc, Qtz, Other m.p.
VCT & Mastic, Main Breakroom
Floor Tile-TanMay-26-16
Split A
834-00065-001B
1. 1-5% Chrysotile 1-5% Cellulose 90-98% Tar, Other m.p.
VCT & Mastic, Main Breakroom
Mastic-BlackMay-26-16
Split B
Limit of quantitation of method is estimated to be 1% asbestos using a visual area estimation technique.
Split samples are inhomogeneous.
DESCRIPTION
1 of 1Page:
ASBESTOS TEM LABORATORIES, INC. 1350 Freeport Blvd., Unit 104, Sparks, NV 89431 (775) 359-3377
Split Layers Analyzed: 1
1) Non-Asbestos Fibers
2) Matrix Materials
3) Date/Time Collected
4) Date Analyzed
1) 2)
3) 4) 1) 2)
3) 4) 1) 2)
3) 4)
1) 2)
3) 4) 1) 2)
3) 4) 1) 2)
3) 4) 1) 2)
3) 4) 1) 2)
3) 4) 1) 2)
3) 4)
1) 2)
3) 4)
With Main Office in Berkeley, CA (510) 704-8930
NVLAP Lab Code 200104-0
Greg Hanes
| *** LABMANAGER *** |
| *** LABMANAGER *** |
| *** LABMANAGER *** |
| COC Sierra Army Depot 131144.pdf |
File details come from the government source that posted it. Updated .