Asbestos_Floor_Tile_Report_671_Break_room_26_May_16.pdf

PDF 161 KB Posted

Attached to
Upgrade Breakroom 671
Solicitation number
W912GY16T0035
Issued by

About this file

Asbestos Floor Tile Report

View the file

Other files

File Type Posted
BLDG_671_BREAKROOM_CABINET.pdf PDF
Questions_and_Answers_Set_5.doc DOC document
QUESTIONS_AND_ANSWERS_SET_4.doc DOC document
Epoxy_Broadcast_Floor_Coating_system.doc DOC document
Site_Visit_Sign_In_Sheet.pdf PDF
Questions_and_Answers_Set_3.doc DOC document
Questions_and_Answers_Set_2.doc DOC document
Questions_and_Answers_Set_1.doc DOC document
Asbestos_Survey.pdf PDF
Amendment_0001.pdf PDF
W912GY-16-T-0035.pdf PDF
Drawing_-_671_Breakroom_Cabinet.pdf PDF
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Report No.

ASBESTOS TEM LABORATORIES, INC.

Analytical Report Polarized Light Microscopy

1350 Freeport Blvd., Unit 104 Sparks, NV 89431

(775) 359-3377

FAX (775) 359-2798

630 Bancroft Way, Berkeley, CA 94710 Ph. (510) 704-8930 Fax (510) 704-8929

With Main Office Located At:

EPA Method 600/R-93/116

131144

ASBESTOS TEM LABORATORIES, INC

Enclosed please find the bulk material analytical results for one or more samples submitted for asbestos analysis.

The analyses were performed in accordance with EPA Method 600/R-93/116 or 600/M4-82-020 for the determination of asbestos in bulk building materials by polarized light microscopy (PLM). Please note that while PLM analysis is commonly performed on non-friable and fine grained materials such as floor tiles and dust, the EPA method recognizes that PLM is subject to limitations. In these situations, accurate results may only be obtainable through the use of more sophisticated and accurate techniques such as transmission electron microscopy (TEM) or X-ray diffraction (XRD).

Prior to analysis, samples are logged-in and all data pertinent to the sample recorded. The samples are checked for damage or disruption of any chain-of-custody seals. A unique laboratory ID number is assigned to each sample. A hard copy log-in sheet containing all pertinent information concerning the sample is generated. This and all other relevant paper work are kept with the sample throughout the analytical procedures to assure proper analysis.

Each sample is opened in a class 100 HEPA negative air hood. A representative sampling of the material is selected and placed onto a glass microscope slide containing a drop of refractive index oil. The glass slide is placed under a polarizing light microscope where standard mineralogical techniques are used to analyze and quantify the various materials present, including asbestos. The data is then compiled into standard report format and subjected to a thorough quality assurance check before the information is released to the client.

Please note all samples will be held for 3 months from the date of receipt unless otherwise requested by client.

Sincerely Yours, Laboratory Analyst

ASBESTOS TEM LABORATORIES, INC.

--- These results relate only to the samples tested and must not be reproduced, except in full, with the approval of the laboratory. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. ---

Mr. Douglas Vittitow

LABORATORY JOB No.

Bldg 671 Breakroom Floor 1Polarized light microscopy analytical results for bulk sample(s) with

Job Site:

Job No.:

RE: 1 sample split(s)

Sierra Army Depot - DPW Bldg 75 'C' Street Herlong, CA 96113

May-26-16

With Main Office in Berkeley, CA (510) 704-8930

Report No.: 131144

1350 Freeport Blvd. Unit 104 . ..Sparks, NV 89431 (775) 359-3377 FAX (775) 359-2798

NVLAP Lab Code 200104-0

LAB

Bldg 75 'C' Street Herlong, CA 96113

Sierra Army Depot - DPW

EPA Method 600/R-93/116 or 600/M4-82-020

POLARIZED LIGHT MICROSCOPY

ANALYTICAL REPORT

Contact:

Address:

Job Site / No.

% TYPE

Laboratory Analyst

Samples Indicated:

Reg. Samples Analyzed:

ASBESTOS

OTHER DATA

SAMPLE ID FIELD

Lab ID #

Lab ID #

Lab ID #

Lab ID #

Lab ID #

Lab ID #

Lab ID #

Lab ID #

Lab ID #

Lab ID #

Date Submitted:

Date Reported:

Bldg 671 Breakroom Floor

May-24-16 May-26-16

Mr. Douglas Vittitow

131144Report No.

834-00065-001A

1. 1-5% Chrysotile None Detected 95-99% Plast, Calc, Qtz, Other m.p.

VCT & Mastic, Main Breakroom

Floor Tile-TanMay-26-16

Split A

834-00065-001B

1. 1-5% Chrysotile 1-5% Cellulose 90-98% Tar, Other m.p.

VCT & Mastic, Main Breakroom

Mastic-BlackMay-26-16

Split B

Limit of quantitation of method is estimated to be 1% asbestos using a visual area estimation technique.

Split samples are inhomogeneous.

DESCRIPTION

1 of 1Page:

ASBESTOS TEM LABORATORIES, INC. 1350 Freeport Blvd., Unit 104, Sparks, NV 89431 (775) 359-3377

Split Layers Analyzed: 1

1) Non-Asbestos Fibers

2) Matrix Materials

3) Date/Time Collected

4) Date Analyzed

1) 2)

3) 4) 1) 2)

3) 4) 1) 2)

3) 4)

1) 2)

3) 4) 1) 2)

3) 4) 1) 2)