Questions_and_Answers_Set_1.doc

DOC document 23 KB Posted

Attached to
Task Lighting Federal contract opportunity
Solicitation number
W912GY16B0009
Issued by
Department of the Army Materiel Command Contracting Command Detroit Arsenal

View the file

Other files for this federal contract opportunity

Other files attached to Task Lighting, newest first.
File Type Posted
OF_1419.xls XLS spreadsheet
Questions_and_Answers_Set_6.doc DOC document
Questions_and_Answers_Set_5.doc DOC document
Questions_and_Answers_Set_3.doc DOC document
Site_Visit_Sign_In_Sheet.pdf PDF
Bldg_358_Lighting_Layout_08-Sep-16.pdf PDF
Questions_and_Answers_Set_4.doc DOC document
QUESTIONS_AND_ANSWERS_SET_2.doc DOC document
IMG_9715.JPG JPG image
Existing_LED_lights_4.JPG JPG image
Existing_LED_lights.JPG JPG image
Existing_LED_lights_3.JPG JPG image
Drawing_-_Bldg.306_Lighting_Layout_28-Jul-16.pdf PDF
Drawing_-_Bldg_358_Lighting_Layout_28-Jul-16.pdf PDF
Existing_LED_lights_1.JPG JPG image
Existing_LED_lights_2.JPG JPG image
BLDG_307_Lighting_Layout_08Aug16.pdf PDF
Drawing_Ver_2.pdf PDF
W912GY-16-B-0009.pdf PDF
Drawing_-_Bldg._310_Lighting_Layout_28-Jul-16.pdf PDF
Existing_LED_lights_5.JPG JPG image
Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Questions and Answers Set 1

1. On the scope, it shows panel, device and general wiring for 308 and

307. The pricing breakdown shows all 5 buildings but the description only includes lighting for all 5. How is the power priced?

ANSWER: Install the lights and ice machine as stated in the Statement of Work.

2. 1.3.14 Ice Machine.

a. Where is the water connection for this machine?

b. Is one of the receptacles shown near the restrooms for the machine?

ANSWER: ) Install the stated machine as stated. The location outside the restrooms shown on the drawing. The single outlet shown will power the ice machine. Water is present at the location, 1/2" copper, solder joints.

3. Bldg. 308. Outlet shown next to new panel noted as 3 phase. Do you have the device configuration needed?

ANSWER: See attached photo.

File details come from the government source that posted it. Updated .