This federal contract opportunity notice seeks proposals for the construction of an Access Control Point at the Watervliet Arsenal in Watervliet, New York. The project includes constructing a combined gate house and search area building, guard booths, overwatch, truck and POV search canopies, active and passive vehicle barriers, entry gates, traffic arms, crash beams, traffic signals, an anti-ram wall, roads and pavements, a standby generator, uninterrupted power system and automatic transfer switch. Existing buildings and structures will be demolished. Required work elements are earthwork, structures, water and sewer utilities, thermal and moisture protections, finishes, electrical distribution and lighting, fire detection and alarm, and demolition. The solicitation will be posted on the SAM website on or about June 30th, with proposals due approximately 30 days later. The contract is valued between $10-20 million and is set aside for small businesses. Questions must be submitted in writing to the named contracting officer by email.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Watervliet Arsenal, Commercial Access Control Point, Gillespie Gate

Watervliet, New York

PROJECT W912-DS-22-______

Volume 5

Structural Interior Design (SID)

Ready to Advertise

Prepared for:

USACE, New York District

26 Federal Plaza

New York, NY 10278-0090

Prepared By:

KZF Design 700 Broadway Street

Cincinnati, Ohio 45202

W9128-F-17-D-0010

01 April 2022

Gillespie Gate, Watervliet NY Ready to Advertise

Commercial Vehicle Access Control Point April 1, 2022

Interiors Narrative

GENERAL

All work shall be designed and constructed in accordance with the applicable provisions of the documents below. UFC’s are the governing documents unless specifically stated otherwise in the applicable UFC.

• UFC 3-101-01 (Change 5, Sept 2019) Architecture

• ER-1110-345-122 (1989) Interior Design

• IBC 2015

• NFPA

• ABA Architectural Barriers Act Accessibility Guidelines

• ANSI/ASHRAE/USGBC/IES Standard 189.1 (2014) Standard for the Design of High Performance, Green Buildings Except Low Rise Residential Buildings

NEW WORK

Gatehouse

The Gatehouse will contain a Command-and-Control room, Restroom, Inside Storage, Mechanical/Electric, and Communications rooms. Interior partitions are to be metal framing with 5/8” gypsum board. Exterior doors and frames to be hollow metal, painted in semigloss finish.

Porcelain tile floors with coordinating tile wall base will be provided at the Command & Control room, Restroom, and Inside Storage. Sealed concrete floors are to be provided for Communications, and Mech/Elec

Rooms with coordinating rubber wall base.

Provide suspended acoustical tile ceiling with recessed light fixtures, hold down clips and exposed grid in

Command & Control Room. All other rooms to receive painted, gypsum board ceilings with recessed light fixtures.

Walls are to be painted with an eggshell finish, epoxy finish at masonry walls.

All windowsills are to be solid surface material. Provide mop sink and mop holder with shelf for the Inside

Storage room. See drawing I-101 for Finish Specifications.

Search Building

The Search Building will contain an Office, Breakroom, Restroom, Inside Storage, Outside Storage, Mechanical/Electric, and Communications rooms. Interior partitions are to be metal framing with 5/8” gypsum board. Interior doors and frames to be hollow metal, painted in semigloss finish.

Porcelain tile floors with coordinating tile wall base will be provided at the Office, Breakroom, Restroom and

Inside Storage. Sealed concrete floors with coordinating rubber wall base are to be provided for

Communications, Mech/Elec, and Outside Storage.

Provide suspended acoustical tile ceiling in a grid pattern with recessed light fixtures, and an exposed grid in the Office and Breakroom. All other rooms to receive painted gypsum board ceilings with recessed light fixtures.

Gillespie Gate, Watervliet NY Ready to Advertise

Commercial Vehicle Access Control Point April 1, 2022

Walls are to be painted with an eggshell finish, epoxy finish at masonry walls. All windowsills are to be solid surface material. Provide mop sink and mop holder with shelf for the Inside Storage room.

See drawing I-101 for Finish Specifications.

Furnishings consists of the following: For the Office space; an ergonomic task chair, two guest chairs and wardrobe/storage tower for the Office, a round table with four chairs and a recycling unit for the Break room.

Refer to the FFE package for details.

Guard Booth

Guard Booths (2) will be pre-manufactured units 4’-0” wide by 10’-0” long minimum.

An ergonomic task stool is provided, for the Command-and-Control room, in the FFE package.

T

COMMUNICATIONS

MECH / ELEC

INSIDE

STORAGE

RESTROOM

COMMAND AND

CONTROL

F01

F01

F01

F01

F03

N01

INTERIOR FINISH SPECIFICATIONS

FT-1

FLOOR TILE (FT)

P-1

PAINT (P)

RB-1

RESILIENT BASE (RB)

TB-1

TILE BASE (TB)

SS-1

SOLID SURFACE (SS)

ACT-1

ACOUSTICAL CEILING TILE (ACT)

P-2

SC-1

SEALED/STAINED CONCRETE (SC)

MFR: DALTILE

STYLE: HAUT MONDE

COLOR: ELITE GREY

FINISH: MATTE

SIZE: 12" X 24" x 3/8"

INSTALLATION: PATTERN TO RUN

NORTH TO SOUTH

GROUT: MAPEI 47 CHARCOAL

SEE SPECIFICATIONS FOR

DETAILS

MFR: JOHNSONITE

STYLE: COVE

COLOR: CHARCOAL 20

SIZE: 4"

MFR: DALTILE

STYLE: HAUT MONDE S36C9S36C9

COLOR: ELITE GREY

FINISH: MATTE

SIZE: 6" X 12" x 3/8"

INSTALLATION:

GROUT: MAPEI 47 CHARCOAL

MFR: SHERWIN WILLIAMS

COLOR: REPOSE GREY SW7015

FINISH: EGGSHELL

FINISH: EPOXY AT MASONRY WALLS

MFR: SHERWIN WILLIAMS

COLOR: GRIZZLE GREY SW7068

FINISH: SEMIGLOSS

INSTALL: HOLLOW METAL FRAMES

MFR: LG HAUSYS MI-MACS

STYLE: EBONY CONCRETE

THICKNESS: 1/2"

INSTALL: CASEWORK AND WINDOW SILLS

MFR: ARMSTRONG CEILINGS

STYLE: CALLA

COLOR: WHITE

SIZE: 2' X 2' x 1"

GRID: 15/16 EXPOSED GRID

SOUND RATING: 0.85

CP-1

CEILING PAINT (CP)

MFR: SHERWIN WILLIAMS

COLOR: PURE WHITE SW7005

FINISH: FLAT

PL-1

PLASTIC LAMINATE (PL-1)

MFR: FORMICA

STYLE: BRUSH

COLOR: 9319-BH

STAINLESS

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

04-01-2022

I-101

G A

T E

H O

U S

E

F

IN

IS

H

P L A

N

S C

H E

D U

L E

A N

D S

P E

C

IF

IC

A

T

IO

N S

G

IL

L E

S P

IE

G

A T

E

W

A T

E R

V L

IE

T N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

T

H F

L O

O R

N E

W Y

O R

K N

Y

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T C

IN

C

IN

N

A T

I, O

H

K E

L L Y

K E

L L Y

S C

H M

IT

Z

-0

-2

W D

S F

W F

D

F

IR

S T

T

IT

L E

S E

C O

N D

T

IT

L E

04-01-2022 READY TO ADVERTISE SET

C O

M M

E R

C

IA

L V

E H

IC

L E

A C

C E

S S

C O

N T

R O

L P

O

IN

T

1/4" = 1'-0"A7

GATEHOUSE - FINISH PLAN

INTERIOR FINISH SCHEDULE

ROOM

NO

ROOM

NAME FLOOR

FLOOR Base Finish

WALL FINISH CEILING FINISH

REMARKSFIN NORTH EAST SOUTH WEST FIN

100 COMMAND AND CONTROL TOP / SLAB FT-1 TB-1 P-1 P-1 P-1 P-1 ACT-1 EXTERIOR

101 RESTROOM TOP / SLAB FT-1 TB-1 P-1 P-1 P-1 P-1 CP-1

102 INSIDE STORAGE TOP / SLAB FT-1 TB-1 P-1 P-1 P-1 P-1 CP-1

103 MECH / ELEC TOP / SLAB SC-1 RB-1 P-1 P-1 P-1 P-1 CP-1 EXTERIOR

104 COMMUNICATIONS TOP / SLAB SC-1 RB-1 P-1 P-1 P-1 P-1 CP-1 EXTERIOR

A REFERENCE THIS FINISH PLAN I-101

FOR FINISH LOCATIONS AND INTERIOR

FINISH SCHEDULE.

B REFERENCE CEILING PLANS AND

SCHEDULE FOR CEILING TYPES. PAINT

ALL GYP. BD. CEILINGS, SOFFITS AND

BULKHEADS CP-1, UNLESS NOTED

OTHERWISE ON FINISH PLAN AND

FINISH SCHEDULE.

C ALL WALLS ARE TO BE PAINTED P-1

UNLESS NOTED OTHERWISE ON THIS

PLAN OR SCHEDULE. ANY

DISCREPANCIES ARE TO BE BROUGHT

TO THE DESIGNERS ATTENTION PRIOR

TO PAINTING.

D PROVIDE WINDOW SILLS IN SOLID

SURFACING SS-1.

E ALL ACCESS PANELS OR DIFFUSERS

ARE TO BE PAINTED A SEMI-GLOSS

FINISH TO MATCH ADJACENT WALL

FINISH UNLESS NOTED OTHERWISE.

F CONTINUE SPECIFIED PAINT ABOVE

AND BELOW ALL MILLWORK COUNTERS

AND CABINETS.

G ALL FREESTANDING COLUMNS, IF ANY,

ARE TO BE PAINTED P-1 UNLESS

NOTED OTHERWISE.

H ALL BUILDING HOLLOW METAL DOORS

AND DOOR FRAMES TO BE PAINTED P-2

UNLESS NOTED OTHERWISE.

I ALL DOORS CALLED OUT TO BE

PAINTED ARE TO BE PAINTED P-2

UNLES NOTED OTHERWISE.

J PAINT ALL EXPOSED PIPING, CONDUIT,

ELECTRICAL DEVICES, DUCTWORCT,

ETC, TO MATCH P-2 UNLESS NOTED

OTHERWISE.

K INSTALL FLOORING UNDER ALL BASE

CABINETS AND INSTALL SCHEDULED

BASE ON TOEKICK OF ALL BASE

CABINETS, UNLESS NOTED OTHERWISE

ON THE ELEVATION, FINISH PLAN OR

THE DETAIL.

L ALL CHANGES IN FLOORING BETWEEN

ROOMS IS TO OCCUR AT CENTERLINE

OF DOOR.

M ALL TRIM AND BASE TO TERMINATE

INTO NEAREST INSIDE CORNER,

UNLESS NOTED OTHERWISE.

GENERAL NOTES

F01 PROVIDE APPROPRIATE FLOOR TRANSITION TO

EXTERIOR. SEE ARCHITECTURAL DRAWINGS.

F03 SOLID SURFACE COUNTER TOP TO BE SS-1.

DRAWING NOTES

1 REFERENCE FINISH PLANS FOR DRAWING NOTES.

FINISH REMARKS

0 2' 4' 8'

N N

TRUE NORTH PLAN NORTH

N01 TAG: S2, SEE FFE PACKAGE FOR CHAIR DETAILS.

COMMUNICATIONS

MECH / ELEC

INSIDE

STORAGE

RESTROOM

COMMAND AND

CONTROL

S05

S03

S02

S05

S04

S04

S06S06

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

04-01-2022

I-121

G A

T E

H O

U S

E

S

IG

N A

G E

P L A

N A

N D

S C

H E

D U

L E

G

IL

L E

S P

IE

G

A T

E

W

A T

E R

V L

IE

T N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

T

H F

L O

O R

N E

W Y

O R

K N

Y

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T C

IN

C

IN

N

A T

I, O

H

K E

L L Y

K E

L L Y

S C

H M

IT

Z

-0

-2

W D

S F

W F

D

F

IR

S T

T

IT

L E

S E

C O

N D

T

IT

L E

04-01-2022 READY TO ADVERTISE SET

C O

M M

E R

C

IA

L V

E H

IC

L E

A C

C E

S S

C O

N T

R O

L P

O

IN

T

1/4" = 1'-0"1

GATEHOUSE - SIGNAGE PLAN

N N

TRUE NORTH PLAN NORTH

GENERAL NOTES

A ALL SIGNS TO FOLLOW ADAAG GUIDELINES,

CONTRACTORS TO VERIFY THESE GUIDELINES.

REFERENCE SPECIFICATION SECTION 10 14 02 FOR

DETAILS.

B REFERENCE I-511 DRAWING FOR SIGN

GRAPHICS/DETAILS. SIGNAGE DETAILS TO FOLLOW

AIRFORCE SIGN STANDARDS UFC 3-120-01 AND

DEPARTMENT OF ARMY MANUAL 5-807-10, SECTION

4.1.

C CONTRACTOR TO VERIFY WITH BASE ANY FACILITY

STANDARDS OR ORGANIZATIONAL

EMBLEMS/SYMBOLS TO BE USED.

D ALL SIGNS TO BE LOCATED 3" FROM LATCH SIDE OF

DOOR, MOUNTED 60 INCHES A.F.F TO THE

CENTERLINE OF SIGN. IF THERE IS INSUFFICIENT

ROOM ON THE LATCH SIDE OF THE DOORTO INSTALL

THE SIGN, THEN SIGNS ARE TO BE POSITIONED TO

THE NEAREST ADJACENT WALL OF THE DOOR LATCH.

E ANY SIGN PLAQUE MOUNTED TO WINDOW GLAZING IS

TO HAVE A BLANK SIGN PLAQUE WITH MATCHING

FINISHES MOUNTED TO BACK SIDE OF THE GLASS.

F MOUNTING HEIGHTS IDENTIFYING ROOMS MUST BE

MOUNTED SO THAT THE BOTTOM OF THE RAISED

CHARACTERS ARE BETWEEN 48 INCHES AND 60

INCHES ABOVE THE FLOOR.

G ALL SIGNS TO BE LOCATED 3" FROM LATCH SIDE OF

DOOR, MOUNTED 60 INCHES A.F.F TO THE

H INTERIOR SIGN FINISHES - COPY/TEXT TO BE WHITE,

BACKGROUND COLOR TO BE BLACK.

INTERIOR SIGNAGE SCHEDULE

Number Name Sign Type

Sign Quantity

Sign Header Panel Sign Line Text 1

Sign Line Text 2 Mounting Braille Comments

100 COMMAND AND

CONTROL

S5 2 100 COMMAND AND CONTROL EXTERIOR

WALL

NO EXTERIOR

100 COMMAND AND

CONTROL

S6 2 --- (NO SMOKING SYMBOL) NO SMOKING WALL NO

101 RESTROOM S3 1 101 (UNISEX 'GRAPHIC SYMBOL') RESTROOM WALL YES

102 INSIDE STORAGE S2 1 102 STORAGE WALL YES

103 MECH / ELEC S4 1 103 MECHANICAL AND ELECTRICAL EXTERIOR

WALL

NO EXTERIOR

104 COMMUNICATIONS S4 1 104 COMMUNICATIONS EXTERIOR

WALL

NO EXTERIOR

S02 PROVIDE SIGN TYPE S2 AT THIS LOCATION.

S03 PROVIDE SIGN TYPE S3 AT THIS LOCATION.

S04 PROVIDE SIGN TYPE S4 AT THIS LOCATION.

S05 PROVIDE SIGN TYPE S5 AT THIS LOCATION.

S06 PROVIDE SIGN TYPE S6 AT THIS LOCATION.

DRAWING NOTES

BREAK ROOM

OFFICE

COMMUNICATIONS

116 MECH / ELEC

OUTSIDE

STORAGE

INSIDE

STORAGE

RESTROOM

F01

F01

F01

F02

INTERIOR FINISH SPECIFICATIONS

FT-1

FLOOR TILE (FT)

P-1

PAINT (P)

RB-1

RESILIENT BASE (RB)

TB-1

TILE BASE (TB)

SS-1

SOLID SURFACE (SS)

ACT-1

ACOUSTICAL CEILING TILE (ACT)

P-2

SC-1

SEALED/STAINED CONCRETE (SC)

MFR: DALTILE

STYLE: HAUT MONDE

COLOR: ELITE GREY

FINISH: MATTE

SIZE: 12" X 24" x 3/8"

INSTALLATION: PATTERN TO

RUN EAST TO WEST

GROUT: MAPEI 47 CHARCOAL

SEE SPECIFICATIONS FOR

DETAILS

MFR: JOHNSONITE

STYLE: COVE

COLOR: CHARCOAL 20

SIZE: 4"

MFR: DALTILE

STYLE: HAUT MONDE S36C9S36C9

COLOR: ELITE GREY

FINISH: MATTE

SIZE: 6" X 12" x 3/8"

INSTALLATION:

GROUT: MAPEI 47 CHARCOAL

MFR: SHERWIN WILLIAMS

COLOR: REPOSE GRAY SW7015

FINISH: EGGSHELL

FINISH: EPOXY AT MASONRY WALLS

MFR: SHERWIN WILLIAMS

COLOR: GRIZZLE GRAY SW7068

FINISH: SEMIGLOSS

INSTALL: HOLLOW METAL FRAMES

MFR: ARMSTRONG CEILINGS

STYLE: CALLA

COLOR: WHITE

SIZE: 2' x 2' X 1"

GRID: 15/16 EXPOSED GRID

SOUND RATING: 0.85 NRC

CP-1

CEILING PAINT (CP)

MFR: SHERWIN WILLIAMS

COLOR: PURE WHITE SW7005

FINISH: FLAT

PL-1

PLASTIC LAMINATE (PL-1)

MFR: FORMICA

STANDARD HPL

STYLE: BRUSH

COLOR: 9319-BH

STAINLESS

MFR: LG HAUSYS HI-MACS

STYLE: M553 EBONY CONCRETE

THICKNESS: 1/2"

INSTALL: CASEWORK AND WINDOW SILLS

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

04-01-2022

I-102

S E

A R

C H

B L D

G

F

IN

IS

H

P L A

N

S C

H E

D U

L E

A N

D S

P E

C

IF

IC

A

T

IO

N S

G

IL

L E

S P

IE

G

A T

E

W

A T

E R

V L

IE

T N

Y

N E

W Y

O R

K

D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

T

H F

L O

O R

N E

W Y

O R

K N

Y

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

C

IN

C

IN

N

A T

I O

H

ID

K E

L L Y

K E

L L Y

S C

H M

IT

Z

-0

-2

W D

S F

W F

D

O P

T

IO

N A

L F

IE

L D

F

IR

S

T T

IT

L E

S E

C O

N D

T

IT

L E

04-01-2022 READY TO ADVERTISE SET

C O

M M

E R

C

IA

L V

E H

IC

L E

A C

C E

S S

C O

N T

R O

L P

O

IN

T

P R

O J E

C T

O P

T

IO

N A

L F

IE

L D

1/4" = 1'-0"A7

SEARCH BLDG - FLOOR PLAN

USACE_FINISH SCHEDULE

ROOM

NO

ROOM

NAME FLOOR

FLOOR Base Finish

WALL FINISH CEILING FINISH

REMARKSFIN NORTH EAST SOUTH WEST FIN

110 OFFICE TOP / SLAB FT-1 TB-1 P-1 P-1 P-1 P-1 ACT-1 EXTERIOR

111 BREAK ROOM TOP / SLAB FT-1 TB-1 P-1 P-1 P-1 P-1 ACT-1

112 INSIDE STORAGE TOP / SLAB FT-1 TB-1 P-1 P-1 P-1 P-1 CP-1

113 RESTROOM TOP / SLAB FT-1 TB-1 P-1 P-1 P-1 P-1 CP-1

114 OUTSIDE STORAGE TOP / SLAB SC-1 RB-1 P-1 P-1 P-1 P-1 CP-1 EXTERIOR

115 MECH / ELEC TOP / SLAB SC-1 RB-1 P-1 P-1 P-1 P-1 CP-1 EXTERIOR

116 COMMUNICATIONS TOP / SLAB SC-1 RB-1 P-1 P-1 P-1 P-1 CP-1 EXTERIOR

F01 PROVIDE APPROPRIATE FLOOR TRANSITION TO EXTERIOR. SEE

ARCHITECTURAL DRAWINGS.

F02 SOLID SURFACE COUNTER TOP TO BE SS-1. BASE CABINETS, PL-1.

DRAWING NOTES

A REFERENCE THIS FINISH PLAN I-102 FOR FINISH LOCATIONS AND INTERIOR FINISH

SCHEDULE.

B REFERENCE CEILING PLANS AND SCHEDULE FOR CEILING TYPES. PAINT ALL GYP. BD.

CEILINGS, SOFFITS AND BULKHEADS CP-1, UNLESS NOTED OTHERWISE ON FINISH PLAN

AND FINISH SCHEDULE.

C ALL WALLS ARE TO BE PAINTED P-1 UNLESS NOTED OTHERWISE ON THIS PLAN OR

SCHEDULE. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE DESIGNERS ATTENTION

PRIOR TO PAINTING.

D PROVIDE WINDOW SILLS IN SS-1.

E ALL ACCESS PANELS OR DIFFUSERS ARE TO BE PREFABBED WHITE UNLESS NOTED

OTHERWISE.

F CONTINUE SPECIFIED PAINT ABOVE AND BELOW ALL MILLWORK COUNTERS AND CABINETS.

G ALL FREESTANDING COLUMNS, IF ANY, ARE TO BE PAINTED P-1 UNLESS NOTED

OTHERWISE.

H ALL BUILDING HOLLOW METAL DOORS AND DOOR FRAMES TO BE PAINTED P-2 UNLESS

NOTED OTHERWISE.

I ALL DOORS CALLED OUT TO BE PAINTED ARE TO BE PAINTED P-2 UNLES NOTED

OTHERWISE.

J PAINT ALL EXPOSED PIPING, CONDUIT, ELECTRICAL DEVICES, DUCTWORCT, ETC, TO MATCH

P-2 UNLESS NOTED OTHERWISE.

K INSTALL FLOORING UNDER ALL BASE CABINETS AND INSTALL SCHEDULED BASE ON

TOEKICK OF ALL BASE CABINETS, UNLESS NOTED OTHERWISE ON THE ELEVATION, FINISH

PLAN OR THE DETAIL.

L ALL CHANGES IN FLOORING BETWEEN ROOMS IS TO OCCUR AT CENTERLINE OF DOOR.

M ALL TRIM AND BASE TO TERMINATE INTO NEAREST INSIDE CORNER, UNLESS NOTED

OTHERWISE.

GENERAL NOTES

FINISH REMARKS

1 REFERENCE FINISH PLAN FOR DRAWING NOTES.

N

0 4'2' 8'

N

TRUE NORTH PLAN NORTH

1 1/2" TACTILE ROOM NUMBER

WITH BRAILLE, HELVETICA

MEDIUM (38 MM)

1/2" (13 MM) TACTILE

ROOM DESCRIPTION

STORAGE

(PERMANENT ROOM ID SIGN)

REMOVABLE END

CAPS (BOTH SIDES)

8 1/2"

9"

6" (152MM)

APPROPRIATE

SYMBOL PER SIGN

SCHEDULE

UNISEX 1" (25MM) TACTILE ROOM

DESCRIPTION WITH

BRAILLE, HELVETICA

NEUE 65 MEDIUM

REMOVABLE END

CAPS (BOTH SIDES)

OPTIONAL 1 1/2"

(38MM) TACTILE

ROOM NUMBER

WITH BRAILLE

HELVETICA NEUE

65 MEDIUM

(ACCESSIBLE RESTROOM ID SIGNS)

9"

8 1/2"

ROOM NUMBER,

HELVETICA NEUE 65

MEDIUM 38MM FLUSH

LEFT

UPPER CASE

HELVETICA NEUE

19MM CAPITAL

LETTER HEIGHT

FLUSH LEFT.

COMMUNICATIONS

3MM REVEAL

(EXTERIOR GRADE SIGN)

9"

BLDG NUMBER

3/8" (10 MM)

HELVETICA NEUE 75

BOLD UPPER &

LOWER CASE

Gatehouse

Anti-terrorism Perimeter Security Entry Control Facility

(BUILDING ENTRANCE SIGN)

HEADQUARTERS

HELVETICA NEUE

MEDIUM (STREET

ADDRESS MAY BE

USED HERE)

EXTERIOR GRADE

2'-0"

UPPER CASE

HELVETICA

MEDIUM, 4" (100MM)

HEIGHT

LETTERS AND

NUMBERS IN WHITE

TEXT ON BROWN

BACKGROUND, BASE

STANDARD

SYMBOL:

BLACK AND

RED ON WHITE

BACKGROUND

No Smoking

UPPER AND LOWER CASE

HELVETICA NEUE 55 ROMAN,

19MM CAPITAL LETTER

HEIGHT

END CAPS

(MANDATORY & PROHIBITORY SIGNS)

6"

" PAPER INSERT

M

IN

IM

U

M

SIGN

TYPE

0' - 3"

RAISED CHARACTERS SHALL BE 48 INCHES MINIMUM ABOVE

THE FLOOR, MEASURED TO THE BASELINE OF THE LOWEST

RAISED CHARACTER AND 60 INCHES MAXIMUM ABOVE THE

FLOOR, MEASURED TO THE BASELINE OF THE HIGHEST RAISED

CHARACTER. PER ABAAS GUIDE LINES.

M A

X

SIGN TYPE

S5

1'-6"1'-0"

D O

O R

F R

A M

E H

E

IG

H T

BUILDING-MOUNTED ENTRY SIGN PLACEMENTWALL MOUNTED INTERIOR SIGN PLACEMENT

M

IN

IM

U

M

SIGN

TYPE

1' - 3 3/4"0' - 8 1/2"1' - 3 3/4"

M A

X

DOOR MOUNTED INTERIOR SIGN PLACEMENT

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

04-01-2022

I-511

G A

T E

H O

U S

E

S

IG

N A

G E

D E

T A

IL

S

G

IL

L E

S P

IE

G

A T

E

W

A T

E R

V L

IE

T N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

T

H F

L O

O R

N E

W Y

O R

K N

Y

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T C

IN

C

IN

N

A T

I, O

H

K E

L L Y

K E

L L Y

S C

H M

IT

Z

-0

-2

W D

S F

W F

D

F

IR

S T

T

IT

L E

S E

C O

N D

T

IT

L E

04-01-2022 READY TO ADVERTISE SET

C O

M M

E R

C

IA

L V

E H

IC

L E

A C

C E

S S

C O

N T

R O

L P

O

IN

T

1 : 51

SIGN TYPE S2

1 : 52

SIGN TYPE S3

1 : 53

SIGN TYPE S4

1 : 54

SIGN TYPE S5

1 : 55

SIGN TYPE S6

GENERAL NOTES

A REFER TO I-121 FOR SIGNAGE PLAN, SCHEDULE, AND NOTES.

1/2" = 1'-0"6

SIGNAGE MOUNTING HEIGHTS

A

B

C01

C03

C02

9'-4"

8'-0"

9'-4"

9'-4"

9'-4"

C05

C05 C05

C05

C05

C03

C03

C03

C03

EF EF C06

C08

CEILING LEGEND

ACOUSTICAL LAY-IN

CEILING - 2'x2'

SUSPENDED GYPSUM

BOARD CEILING

SURFACE MOUNTED LIGHT FIXTURE

LAY-IN LIGHT FIXTURE - 2x2

AIR DEVICE - SUPPLY

AIR DEVICE - RETURN

EXHAUST FAN

RETURN AIR GRILLE

EF

EMERGENCY LIGHTING

EMERGENCY LIGHTING

TOP / SLAB

0' - 0"

TRUSS BEARING

9' - 4"

1 2

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

04-01-2022

A-105

G A

T E

H O

U S

E R

E F

L E

C T

E D

C E

IL

IN

G P

L A

N

G

IL

L E

S P

IE

G

A T

E

W

A T

E R

V L

IE

T N

Y

N E

W Y

O R

K D

IS

T

R

IC

T

F

E D

E R

A L P

L A

Z A

T

H F

L O

O R

N E

W Y

O R

K N

Y

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T C

IN

C

IN

N

A T

I, O

H

S C

H M

IT

Z

S C

H M

IT

Z

S C

H M

IT

Z

-0

-2

W D

S F

W F

D

F

IR

S T

T

IT

L E

S E

C O

N D

T

IT

L E

04-01-2022 READY TO ADVERTISE SET

C O

M M

E R

C

IA

L V

E H

IC

L E

A C

C E

S S

C O

N T

R O

L P

O

IN

T

1/4" = 1'-0"A6

GATEHOUSE CEILING PLAN

C01 METAL PANEL SOFFIT

C02 PRE-FINISHED GUTTER

C03 PRE-FINISHED DOWNSPOUT

C05 EXTERIOR LIGHT FIXTURE - REFER

ELECTRICAL DRAWINGS

C06 WALL MOUNTED LIGHT FIXTURE - REFER

ELECTRICAL DRAWINGS

C08 DUCTLESS HEAT PUMP - REFER

MECHANICAL DRAWINGS

DRAWING NOTES

0 2' 4' 8'

ENVELOPE AREAS

NORTH WALL 148 SF

SOUTH WALL 148 SF

EAST WALL 462 SF

WEST WALL 462 SF

FLOOR 867 SF

ROOF 1195 SF

1/4" = 1'-0"A1

AIR BARRIER SECTION

SLAB ON GRADE

REINFORCED CONCRETE SLAB ON GRADE OVER

VAPOR BARRIER AND CONTINUOUS RIGID

INSULATION

FINISH FLOOR AS SCHEDULED

EXTERIOR WALLS

EXTERIOR - CONCRETE MASONRY UNITS WITH

CONTINUOUS RIGID INSULATION AND BRICK VENEER

FLUID APPLIED MEMBRANE AIR BARRIER OVER EXTERIOR

FACE OF CMU. PROVIDE CONTINUOUS SEALANT AT ALL

PENETRATIONS

INTERIOR - GYPSUM BOARD OVER METAL STUDS WITH

CLOSED CELL SPRAY FOAM INSULATION PER PLAN.

PROVIDE CONTINUOUS SEALANT AT ALL PENETRATIONS

OPENINGS

STOREFRONT - AS SCHEDULED BALLISTIC RATED

ALUMINUM FRAME / GLAZING. FRAMING ANCHORED

TO CMU WALL AND SEALED ALL AROUND EXTERIOR

AND INTERIOR.

DOORS - AS SCHEDULED. HOLLOW METAL DOORS

AND FRAMES ANCHORED TO CMU WALL OPENING

AND SEALED ALL AROUND EXTERIOR AND

INTERIOR. WEATHER SEALS AT DOOR PERIMETER

MECHANICAL PENETRATIONS - AS INDICATED.

SEAL ALL AROUND EXTERIOR AND INTERIOR.

ROOFS

STANDING SEAM METAL ROOFING OVER RIGID INSULATION

OVER AIR BARRIER OVER ROOF SHEATHING OVER METAL

DECK. CLOSED CELL SPRAY FOAM INSULATION UNDERSIDE

OF DECKING. PROVIDE CONTINOUS SEALANT ALL AROUND

AT ALL ROOF PENETRATIONS

OFFICE

COMMUNICATIONS

116 MECH / ELEC

OUTSIDE

STORAGE

INSIDE

STORAGE

RESTROOM

TOWER

R E

C Y

C L

IN

G

S1

S3(2) S4(4)

PO1

T1

M1

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

04-01-2022

I-112

S E

A R

C H

B L D

G

F U

R N

IT

U

R E

P L A

N

G

IL

L E

S P

IE

G

A T

E

W

A T

E R

V L

IE

T N

Y

N E

W Y

O R

K

D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

T

H F

L O

O R

N E

W Y

O R

K N

Y

K Z

F D

E S

IG

N

B

R O

A D

W A

Y

C

IN

N

A T

I O

H

ID

K E

L L Y

K E

L L Y

S C

H M

IT

Z

-0

-2

W D

S F

W F

D

O P

T

IO

N A

L F

IE

L D

F

IR

S

T T

IT

L E

S E

C O

N D

T

IT

L E

04-01-2022 READY TO ADVERTISE SET

C O

M M

E R

C

IA

L V

E H

IC

L E

A C

C E

S S

C O

N T

R O

L P

O

IN

T

P R

O J E

C T

O P

T

IO

N A

L F

IE

L D

1/4" = 1'-0"1

SEARCH BLDG - FURNITURE PLAN

NN

TRUE NORTH PLAN NORTH

A ALL FURNITURE SHOWN IS REPRESENTATIVE AND DOES NOT NECESSARILY REFLECT ACTUAL

SPECIFICATIONS. REFER TO FFE PACKAGE FOR ALL FURNITURE SPECIFICATIONS AND FINISHES.

B ALL AUDIO VISUAL (A/V) EQUIPMENT BY OTHERS TO BE COORDINATED WITH THE ARCHITECT, GENERAL CONTRACTOR (GC), AND THE A/V CONSULTANT AND/OR CONTRACTOR PRIOR TO ANY

RELATED CONSTRUCTION.

C ALL POWER, DATA AND TELCOM LOCATIONS SHALL BE COORDINATED BETWEEN THE

CONTRACTOR, FURNITURE VENDOR AND GOVERNMENT BASED ON PRODUCT SELECTED.

REFERENCE FURNITURE, ELECTRICAL, DATA AND TELECOM DRAWINGS FOR THE FURNITURE

LOCATION, SIZE, AND TYPE. FURNITURE VENDOR/CONTRACTOR TO COORDINATE QUANTITY OF

CABLES AND ANY WIRING NEEDED PER AWARDED PRODUCT.

GENERAL NOTES

FURNITURE LEGEND

M1 RECYCLE CENTER

PO1 PRIORITY WORKSTATION

S1 ERGONOMIC TASK CHAIR

S2 ERGONOMIC TASK STOOL (GATEHOUSE BUILDING)

S3 GUEST CHAIR WITH ARMS, UPHOLSTERED

S4 STACKABLE POLY CHAIR

T1 MEETING TABLE, 42" ROUND

OFFICE

COMMUNICATIONS

116 MECH / ELEC

OUTSIDE

STORAGE

INSIDE

STORAGE

RESTROOM

S04

S04

S05

S02S03

S01 S06

S06

S04

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

04-01-2022

I-122

S E

A R

C H

B L D

G

S

IG

N A

G E

P L A

N

S C

H E

D U

L E

G

IL

L E

S P

IE

G

A T

E

W

A T

E R

V L

IE

T N

Y

N E

W Y

O R

K

D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

T

H F

L O

O R

N E

W Y

O R

K N

Y

K Z

F D

E S

IG

N

B

R O

A D

W A

Y

C

IN

N

A T

I O

H

ID

K E

L L Y

K E

L L Y

S C

H M

IT

Z

-0

-2

W D

S F

W F

D

O P

T

IO

N A

L F

IE

L D

F

IR

S

T T

IT

L E

S E

C O

N D

T

IT

L E

04-01-2022 READY TO ADVERTISE SET

C O

M M

E R

C

IA

L V

E H

IC

L E

A C

C E

S S

C O

N T

R O

L P

O

IN

T

P R

O J E

C T

O P

T

IO

N A

L F

IE

L D

1/4" = 1'-0"1

SEARCH BLDG - FLOOR PLAN

N

0 4'2' 8'

N

TRUE NORTH PLAN NORTH

A ALL SIGNS TO FOLLOW ADAAG GUIDELINES, CONTRACTORS TO

VERIFY THESE GUIDELINES.REFERENCE SPECIFICATION SECTION 10

14 02 FOR DETAILS.

B REFERENCE DRAWING I-512 FOR SIGN GRAPHICS/DETAILS. SIGNAGE

DETAILS TO FOLLOW THE CURRENT REVISION OF AIRFORCE SIGN

STANDARDS UFC 3-120-01 AND DEPARTMENT OF ARMY 5-807-10

SIGNAGE MANUAL, SECTION 4.1.

C CONTRACTOR TO VERIFY WITH BASE ANY FACILITY STANDARDS OR

ORGANIZATIONAL EMBLEMS/SYMBOLS TO BE USED.

D ALL SIGNS TO BE LOCATED 3" FROM LATCH SIDE OF DOOR, MOUNTED

60 INCHES A.F.F TO THE CENTERLINE OF SIGN. IF THERE IS

INSUFFICIENT ROOM ON THE LATCH SIDE OF THE DOOR TO INSTALL

THE SIGN, THEN SIGNS ARE TO BE POSITIONED TO THE NEAREST

ADJACENT WALL OF THE DOOR LATCH.

E ANY SIGN PLAQUE MOUNTED TO WINDOW GLAZING IS TO HAVE A

BLANK SIGN PLAQUE WITH MATCHING

F MOUNTING HEIGHTS IDENTIFYING ROOMS MUST BE MOUNTED SO

THAT THE BOTTOM OF THE RAISED CHARACTERS ARE BETWEEN 48

INCHES AND 60 INCHES ABOVE THE FLOOR. SEE MOUNTING DETAIL

ON THIS DRAWING.

G SIGNS DESIGNATED FOR THE EXTERIOR OF BUILDING TO BE

EXTERIOR GRADE ALUMINUM .080, POWDER COATED.

H INTERIOR SIGN FINISHES - COPY/TEXT COLOR TO BE WHITE,

BACKGROUND COLOR TO BE BLACK.

I EXTERIOR SIGNS - FINISH TO BE WHITE TEXT ON BROWN

BACKGROUND, TO MATCH BASE STANDARDS

GENERAL NOTES

INTERIOR SIGNAGE SCHEDULE

Number Name Sign Type

Sign Quantity

Sign Header Panel Sign Line Text 1

Sign Line Text 2 MOUNTING BRAILLE Comments

110 OFFICE S5 1 110 SEARCH BUILDING EXTERIOR WALL NO EXTERIOR

110 OFFICE S6 1 --- (SYMBOL 'NO SMOKING') NO SMOKING EXTERIOR WALL NO EXTERIOR

111 BREAK ROOM S1 1 111 BREAK ROOM WALL YES

111 BREAK ROOM S6 1 --- (SYMBOL 'NO SMOKING') NO SMOKING WALL NO

112 INSIDE STORAGE S2 1 112 STORAGE WALL YES

113 RESTROOM S3 1 113 (UNISEX & ADA SYMBOL) RESTROOM WALL YES

114 OUTSIDE STORAGE S4 1 114 STORAGE EXTERIOR WALL NO EXTERIOR

115 MECH / ELEC S4 1 115 MECHANICAL / ELECTRICAL EXTERIOR WALL NO EXTERIOR

116 COMMUNICATIONS S4 1 116 COMMUNICATIONS EXTERIOR WALL NO EXTERIOR

S01 PROVIDE SIGN TYPE S1 AT THIS LOCATION.

S02 PROVIDE SIGN TYPE S2 AT THIS LOCATION.

S03 PROVIDE SIGN TYPE S3 AT THIS LOCATION.

S04 PROVIDE SIGN TYPE S4 AT THIS LOCATION.

S05 PROVIDE SIGN TYPE S5 AT THIS LOCATION.

S06 PROVIDE SIGN TYPE S6 AT THIS LOCATION.

DRAWING NOTES

1 1/2" TACTILE ROOM NUMBER

WITH BRAILLE, HELVETICA

NEUE MEDIUM (38 MM)

PRINTED PAPER INSERT WITH

ROOM DESCRIPTION BEHIND

CLEAR ACRYLIC

3/4" PRINTED MESSAGE HELVETICA NEUE

MEDIUM (19MM), UPPER AND LOWER CASE

BLACK LETTERS ON WHITE BACKGROUND

Office Branch Personnel

(ROOM ID SIGN WITH PAPER INSERT)

REMOVABLE END

CAPS (BOTH SIDES)

8 1/2"

9"

1 1/2" TACTILE ROOM NUMBER

WITH BRAILLE, HELVETICA

NEUE 65 MEDIUM (38 MM)

1/2" (13 MM) TACTILE

ROOM DESCRIPTION

STORAGE

(PERMANENT ROOM ID SIGN)

REMOVABLE END

CAPS (BOTH SIDES)

8 1/2"

9"

6" (152MM)

APPROPRIATE

SYMBOL PER SIGN

SCHEDULE

UNISEX 1" (25MM) TACTILE ROOM

DESCRIPTION WITH

BRAILLE, HELVETICA

NEUE 65 MEDIUM

REMOVABLE END

CAPS (BOTH SIDES)

OPTIONAL 1 1/2"

(38MM) TACTILE

ROOM NUMBER

WITH BRAILLE

HELVETICA NEUE

65 MEDIUM

(ACCESSIBLE RESTROOM ID SIGNS)

9"

8 1/2"

ROOM NUMBER,

HELVETICA NEUE

MEDIUM 38MM FLUSH

LEFT

UPPER CASE

HELVETICA NEUE

19MM CAPITAL

LETTER HEIGHT

FLUSH LEFT.

COMMUNICATIONS

3MM REVEAL

(EXTERIOR GRADE SIGN)

9"

SYMBOL:

BLACK AND

RED ON WHITE

BACKGROUND

No Smoking

UPPER AND

LOWER CASE

HELVETICA NEUE

55 ROMAN, 19MM

CAPITAL LETTER

HEIGHT

END CAPS

(MANDATORY & PROHIBITORY SIGNS)

6"

M

IN

IM

U

M

SIGN

TYPE

0' - 3"

RAISED CHARACTERS SHALL BE 48 INCHES MINIMUM ABOVE

THE FLOOR, MEASURED TO THE BASELINE OF THE LOWEST

RAISED CHARACTER AND 60 INCHES MAXIMUM ABOVE THE

FLOOR, MEASURED TO THE BASELINE OF THE HIGHEST RAISED

CHARACTER. PER ABAAS GUIDE LINES.

M A

X

SIGN TYPE

S5

1'-6"1'-0"

D O

O R

F R

A M

E H

E

IG

H T

BUILDING-MOUNTED ENTRY SIGN PLACEMENTWALL MOUNTED INTERIOR SIGN PLACEMENT

BLDG NUMBER

3/8" (10 MM)

HELVETICA NEUE 75

BOLD UPPER &

LOWER CASE

Gatehouse

Anti-terrorism Perimeter Security Entry Control Facility

(BUILDING ENTRANCE SIGN)

HEADQUARTERS

HELVETICA NEUE

MEDIUM (STREET

ADDRESS MAY BE

USED HERE)

EXTERIOR GRADE

2'-0"

UPPER CASE

HELVETICA

MEDIUM, 4" (100MM)

HEIGHT

LETTERS AND

NUMBERS IN WHITE

TEXT ON BROWN

BACKGROUND, BASE

STANDARD

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

04-01-2022

I-512

S E

A R

C H

B L D

G

S

IG

N A

G E

D E

T A

IL

S

G

IL

L E

S P

IE

G

A T

E

W

A T

E R

V L

IE

T N

Y

N E

W Y

O R

K

D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

T

H F

L O

O R

N E

W Y

O R

K N

Y

K Z

F D

E S

IG

N

B

R O

A D

W A

Y

C

IN

N

A T

I O

H

ID

K E

L L Y

K E

L L Y

S C

H M

IT

Z

-0

-2

W D

S F

W F

D

O P

T

IO

N A

L F

IE

L D

F

IR

S

T T

IT

L E

S E

C O

N D

T

IT

L E

04-01-2022 READY TO ADVERTISE SET

C O

M M

E R

C

IA

L V

E H

IC

L E

A C

C E

S S

C O

N T

R O

L P

O

IN

T

P R

O J E

C T

O P

T

IO

N A

L F

IE

L D

1 : 51

SIGN TYPE S1

1 : 52

SIGN TYPE S2

1 : 53

SIGN TYPE S3

1 : 55

SIGN TYPE S4

1 : 56

SIGN TYPE S6

1/2" = 1'-0"7

SIGNAGE MOUNTING HEIGHTS

1 : 54

SIGN TYPE S5

A REFER TO I-122 FOR SIGNAGE PLAN, SCHEDULE, AND NOTES.

GENERAL NOTES

OS

OS

A

B

C01

C02 C03 A7

A-301

A5

A-301

C05

C05

C05

C05

9'-4"

9'-4"9'-4"9'-4"

8'-0"8'-0"

9'-4"

C03

C03

C03

EF

EF

A1

A-106

C07

C06

CEILING LEGEND

ACOUSTICAL LAY-IN

CEILING - 2'x2'

SUSPENDED GYPSUM

BOARD CEILING

SURFACE MOUNTED LIGHT FIXTURE

LAY-IN LIGHT FIXTURE - 2x2

AIR DEVICE - SUPPLY

AIR DEVICE - RETURN

EXHAUST FAN

RETURN AIR GRILLE

EF

EMERGENCY LIGHTING

EMERGENCY LIGHTING

OCCUPANCY SENSOROS

TOP / SLAB

0' - 0"

TRUSS BEARING

9' - 4"

TOF

-3' - 0"

1 2

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

04-01-2022

A-106

S E

A R

C H

B L D

G R

E F

L E

C T

E D

C E

IL

IN

G P

L A

N

G

IL

L E

S P

IE

G

A T

E

W

A T

E R

V L

IE

T N

Y

N E

W Y

O R

K

D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

T

H F

L O

O R

N E

W Y

O R

K N

Y

K Z

F D

E S

IG

N

B

R O

A D

W A

Y

C

IN

N

A T

I O

H

ID

S C

H M

IT

Z

S C

H M

IT

Z

S C

H M

IT

Z

-0

-2

W D

S F

W F

D

O P

T

IO

N A

L F

IE

L D

F

IR

S

T T

IT

L E

S E

C O

N D

T

IT

L E

04-01-2022 READY TO ADVERTISE SET

C O

M M

E R

C

IA

L V

E H

IC

L E

A C

C E

S S

C O

N T

R O

L P

O

IN

T

P R

O J E

C T

O P

T

IO

N A

L F

IE

L D

1/4" = 1'-0"A5

SEARCH BLDG CEILING PLAN

DRAWING NOTES

C01 METAL PANEL SOFFIT

C02 PRE-FINISHED GUTTER

C03 PRE-FINISHED DOWNSPOUT

C05 EXTERIOR LIGHT FIXTURE - REFER

ELECTRICAL DRAWINGS

C06 WALL MOUNTED LIGHT FIXTURE - REFER

ELECTRICAL DRAWINGS

C07 UNIT HEATER - REFER MECHANICAL

DRAWINGS

0 4'2' 8'

ENVELOPE AREAS

NORTH WALL 220 SF

SOUTH WALL 220 SF

EAST WALL 225 SF

WEST WALL 225 SF

FLOOR 658 SF

ROOF 900 SF

SLAB ON GRADE

REINFORCED CONCRETE SLAB ON GRADE OVER

VAPOR BARRIER AND CONTINUOUS RIGID

INSULATION

FINISH FLOOR AS SCHEDULED

EXTERIOR WALLS

EXTERIOR - CONCRETE MASONRY UNITS WITH

CONTINUOUS RIGID INSULATION AND BRICK VENEER

FLUID APPLIED MEMBRANE AIR BARRIER OVER EXTERIOR

FACE OF CMU. PROVIDE CONTINUOUS SEALANT AT ALL

PENETRATIONS

INTERIOR - GYPSUM BOARD OVER METAL STUDS WITH

CLOSED CELL SPRAY FOAM INSULATION PER PLAN.

PROVIDE CONTINUOUS SEALANT AT ALL PENETRATIONS

OPENINGS

STOREFRONT - AS SCHEDULED BALLISTIC RATED

ALUMINUM FRAME / GLAZING. FRAMING ANCHORED

TO CMU WALL AND SEALED ALL AROUND EXTERIOR

AND INTERIOR.

DOORS - AS SCHEDULED. HOLLOW METAL DOORS

AND FRAMES ANCHORED TO CMU WALL OPENING

AND SEALED ALL AROUND EXTERIOR AND

INTERIOR. WEATHER SEALS AT DOOR PERIMETER

MECHANICAL PENETRATIONS - AS INDICATED.

SEAL ALL AROUND EXTERIOR AND INTERIOR.

ROOFS

STANDING SEAM METAL ROOFING OVER RIGID INSULATION

OVER AIR BARRIER OVER ROOF SHEATHING OVER METAL

DECK. CLOSED CELL SPRAY FOAM INSULATION UNDERSIDE

OF DECKING. PROVIDE CONTINUOUS SEALANT ALL AROUND

AT ALL ROOF PENETRATIONS

1/4" = 1'-0"A1

AIR BARRIER SECTION

Gillespie Gate, Watervliet NY Contract: W9128F17D0010 Commercial Vehicle Access Control Point 90% Submittal January 26, 2021

ROOM TYPE: COMMAND CONTROL / INSIDE STORAGE / OFFICE / BREAK RM / RESTROOM

(Page 1 of 2)

TAG / SPEC

SAMPLES

P-1

SHERWIN WILLIAMS

COLOR: REPOSE GRAY

SW7015

FINISH:

EGGSHELL,;EPOXY

FINISH AT MASONRY

WALLS

Location: Main Wall Paint

P-2

COLOR: GRIZZLE GRAY

SW7068

FINISH: SEMI-GLOSS

Location: Hollow Metal Doors and Frames

P-3

COLOR: PURE WHITE

SW7005

FINISH: FLAT

Location: Ceiling Paint

GT-1

MAPEI

COLOR: 47 CHARCOAL

Location: Floor Tile Grout

FT-1

DALTILE

STYLE: HAUT MONDE

COLOR: ELITE GREY

FINISH: MATTE

SIZE: 12 X 24”

BULLNOSE BASE

GROUT: GT-1

Location: Floor tile and Tile Base

CP-1 FT-1

RTA Submittal April, 1, 2022

SS-1

HI-MACS

COLOR: M553 EBONY

CONCRETE

Location: Casework and Windowsills

PL-1

FORMICA

COLOR: 9319-BH

STAINLESS

FINISH: BRUSH

Location: Casework

ROOM TYPE: OUTSIDE STORAGE / COMMUNICATION / MECHANICAL / ELECTRICAL (Page 1 of 1)

P-1

COLOR: REPOSE GRAY

SW7015

FINISH: EGGSHELL

Location:

Main Wall Paint

P-2

COLOR: GRIZZLE GRAY

SW7068

FINISH: SEMI-GLOSS

Location:

Hollow Metal Doors and Frames

RB-1

JOHNSONITE

COLOR: CHARCOAL 20

STYLE: COVE BASE

SIZE: 4” HIGH

Rubber Base

SC-1

SEALED CONCRETE

Sealed Concrete Floors

CEILING FINISHES (Page 1 of 1)

ACT-1

ARMSTRONG

STYLE: CALLA

COLOR: WHITE

SIZE: 2’ X 2’

EDGE: BEVELED

TEGULAR 9/16”

GRID: PRELUDE XL

15/16” EXPOSED TEE

SOUND RATING: NRC

0.75

Acoustical Ceiling Tile

USACE - ACP - Watervliet NY 653003

SECTION 09 30 10

CERAMIC, QUARRY, AND GLASS TILING

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)

ANSI A137.1 (2012) American National Standards Specifications for Ceramic Tile

ASTM INTERNATIONAL (ASTM)

ASTM C373 (2018)Standard Test Methods for Determination of Water Absorption and Associated Properties by Vacuum Method for Pressed Ceramic Tiles and Glass Tiles and Boil Method for Extruded Ceramic Tiles and Non-tile Fired Ceramic Whiteware Products

ASTM C648 (2004; R 2009) Breaking Strength of Ceramic Tile

ASTM C1027 (2009; R 2017) Standard Test Method for Determining Visible Abrasion Resistance of Glazed Ceramic Tile

ASTM D226/D226M (2017) Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing

ASTM D2103 (2015) Standard Specification for Polyethylene Film and Sheeting

ASTM D4068 (2017) Standard Specification for Chlorinated Polyethylene (CPE) Sheeting for Concealed Water-Containment Membrane

SCIENTIFIC CERTIFICATION SYSTEMS (SCS)

SCS SCS Global Services (SCS) Indoor Advantage

TILE COUNCIL OF NORTH AMERICA (TCNA)

TCNA Hdbk (2017) Handbook for Ceramic, Glass, and Stone Tile Installation

U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)

36 CFR 1191 Americans with Disabilities Act (ADA)

SECTION 09 30 10 Page 1

Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines

UNDERWRITERS LABORATORIES (UL)

UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for Contractor Quality Control approval. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government.

Submit the following in accordance with Section 01 33 00 SUBMITTAL

PROCEDURES:

SD-03 Product Data

Porcelain Tile; G

Recycled Content for Porcelain Tile

Setting-Bed; G

Mortar, Grout, and Adhesive; G

SD-04 Samples

Tile; G

SD-07 Certificates

Indoor Air Quality for Adhesives

Indoor Air Quality for Sealants

SD-08 Manufacturer's Instructions

Maintenance Instructions

SD-10 Operation and Maintenance Data

Installation; G

1.3 CERTIFICATIONS

1.3.1 Indoor Air Quality Certifications

1.3.1.1 Adhesives and Sealants

Provide products certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold or provide certification or validation by other third-party programs that products meet the requirements of this Section. Provide current product certification documentation from certification body.When product does not have certification, provide validation that product meets the indoor air

SECTION 09 30 10 Page 2 quality product requirments cited in this Section.

1.4 QUALITY ASSURANCE

Provide installers having a minimum of two years experience with a company specializing in performing the type of work described. Each type and color of tile to be provided from a single source. Each type and color of mortar, adhesive, and grout to be provided from the same source.

1.5 DELIVERY, STORAGE, AND HANDLING

Ship tiles in sealed packages and clearly marked with the grade, type of tile, producer identification, and country of origin. Deliver materials to the project site in manufacturer's original unopened containers with seals unbroken and labels and hallmarks intact. Protect materials from weather, and store them under cover in accordance with manufacturer's printed instructions.

1.6 ENVIRONMENTAL REQUIREMENTS

Do not perform ceramic tile work unless the substrate and ambient temperature is at least 50 degrees F and rising. Maintain temperature above 50 degrees F while the work is being performed and for at least 7 days after completion of the work. When temporary heaters are used, ventilate the area to the outside to avoid carbon dioxide damage to new tilework.

1.7 WARRANTY

Provide manufacturer's standard performance guarantees or warranties that extend beyond a 1-year period.

1.8 EXTRA MATERIALS

Supply an extra 2 percent of each type tile used in clean and marked cartons.

PART 2 PRODUCTS

2.1 TILE

Provide tiles that comply with ANSI A137.1 and are standard grade tiles.

Provide a minimum breaking strength of 125 lbs. for wall tile and 250 lbs.

for floor tile in accordance with ASTM C648. Provide floor tiles with a wet dynamic coefficient of friction (DCOF) value of 0.42 or greater when tested in accordance with ANSI A137.1 requirements. Provide glazed floor tile with a Class IV-Commercial V-Heavy Commercial classification as rated by the manufacturer when tested in accordance with ASTM C1027 for visible abrasion resistance as related to foot traffic. For materials like tile, submit samples of sufficient size to show color range, pattern. Submit manufacturer's catalog data.

2.1.1 Porcelain Tile

Provide unglazed, rectified porcelain tile, cove base and trim pieces with color extending uniformly through the body of the tile. Blend tiles in factory and in a packages to have same color range and continuous blend for installation. Provide tile size(s) of as indicated on drawings. Provide a

0.50 percent maximum water absorption in accordance with ASTM C373.

SECTION 09 30 10 Page 3

Provide Porcelain Tiling Materials that contain a minimum of 10 percent recycled content. Provide data identifying percentage of recycled content for porcelain tile.

2.2 SETTING-BED

Submit manufacturer's catalog data. Compose the setting-bed manufacturer's instructions.

2.3 WATER

Provide potable water.

2.4 MORTAR, GROUT, AND ADHESIVE

Provide certification or validation of indoor air quality for adhesives.

2.4.1 Latex-Portland Cement Mortar

TCNA Hdbk.

2.4.2 Ceramic Tile Grout

TCNA Hdbk; petroleum-free and plastic-free sand portland cement grout latex-portland cement grout.

2.4.3 Sealants

Comply with applicable regulations regarding toxic and hazardous materials and as specified. Grout sealant must not change the color or alter the appearance of the grout. Refer to Section 07 92 00 JOINT SEALANTS.

Provide certification or validation of indoor air quality for sealants.

2.5 SUBSTRATES

2.6 TRANSITION STRIPS

Provide transitions as required. Provide types as recommended by flooring manufacturer for both edges and transitions of flooring materials specified.

Provide transition strips that comply with 36 CFR 1191requirements.

2.7 MEMBRANE MATERIALS

Conform to ASTM D226/D226M, Type 1 for 15 pound waterproofing membrane, asphalt-saturated building felt. Conform to ASTM D2103 or ASTM D4068 4 mil for polyethylene film.

2.8 COLOR, TEXTURE, AND PATTERN

Provide color and pattern as inidcated on drawings. Color listed is not intended to limit the selection of equal colors from other manufacturers.

Provide floor patterns as specified on the drawings.

PART 3 EXECUTION

3.1 GENERAL INSTALLATION REQUIREMENTS

Do not start tile work until roughing in for mechanical and electrical work

SECTION 09 30 10 Page 4 has been completed and tested, and built-in items requiring membrane waterproofing have been installed and tested. Close space, in which tile is being set, to traffic and other work. Keep closed until tile is firmly set. Do not start floor tile installation in spaces requiring wall tile until after wall tile has been installed. Apply tile in colors and patterns indicated in the area shown on the drawings. Install tile with the respective surfaces in true even planes to the elevations and grades shown. Provide special shapes as required for sills, jambs, recesses, offsets, external corners, and other conditions to provide a complete and neatly finished installation. Solidly back tile bases and coves with mortar. Do not walk or work on newly tiled floors without using kneeling boards or equivalent protection of the tiled surface. Submit manufacturer's preprinted installation instructions.

Do not install building construction materials that show visual evidence of biological growth.

3.2 INSTALLATION OF FLOOR TILE

Install floor tile in accordance with TCNA Hdbk method F122 and with grout joints as recommended by the manufacturer for the type of tile.

3.2.1 Dry-Set and Latex-Portland Cement

Use Latex-Portland cement mortar to install tile directly over properly cured, plane, clean concrete slabs in accordance with TCNA Hdbk.

3.2.2 Ceramic Tile Grout

Prepare and install ceramic tile grout in accordance with TCNA Hdbk.

3.2.3 Waterproofing

Shower pans are specified in Section 22 00 00 PLUMBING, GENERAL PURPOSE.

3.3 INSTALLATION OF TRANSITION STRIPS

Install transition strips where indicated, in a manner similar to that of the ceramic tile floor and as recommended by the manufacturer.

3.4 CLEANING AND PROTECTING

Upon completion, thoroughly clean tile surfaces in accordance with manufacturer's approved cleaning instructions. Do not use acid for cleaning glazed tile. Clean floor tile with resinous grout or with factory mixed grout in accordance with printed instructions of the grout manufacturer. After the grout has set, provide a protective coat of a noncorrosive soap or other approved method of protection for tile wall surfaces. Cover tiled floor areas with building paper before foot traffic is permitted over the finished tile floors. Provide board walkways on tiled floors that are to be continuously used as passageways by workmen.

Replace damaged or defective tiles. Submit copy of manufacturer's printed maintenance instructions.

-- End of Section --

SECTION 09 30 10 Page 5

SECTION 09 65 00

RESILIENT FLOORING

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM D4078 (2002; R 2015) Water Emulsion Floor Polish

ASTM F1861 (2016) Standard Specification for Resilient Wall Base

CALIFORNIA DEPARTMENT OF PUBLIC HEALTH (CDPH)

CDPH SECTION 01350 (2010; Version 1.1) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources using Environmental Chambers

GREEN SEAL (GS)

GS-36 (2013) Adhesives for Commercial Use

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD)

SCAQMD Rule 1168 (2017) Adhesive and Sealant Applications

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00

SUBMITTAL PROCEDURES:

SD-03 Product Data

Accessories; G

Adhesives

Wall Base

SD-04 Samples

Wall Base; G

SD-06 Test Reports

Moisture, Alkalinity and Bond Tests; G

SECTION 09 65 00 Page 1

SD-07 Certificates

Indoor Air Quality for Adhesives

SD-08 Manufacturer's Instructions

Surface Preparation

Installation

SD-10 Operation and Maintenance Data

Accessories; G

1.3 DELIVERY, STORAGE, AND HANDLING

Deliver materials to the building site in original unopened containers bearing the manufacturer's name, style name, pattern color name and number, production run, project identification, and handling instructions. Store materials in a clean, dry, secure, and well-ventilated area free from strong contaminant sources and residues with ambient air temperature maintained above 68 degrees F and below 85 degrees F, stacked according to manufacturer's recommendations. Remove resilient products from packaging to allow ventilation prior to installation. Protect materials from the direct flow of heat from hot-air registers, radiators and other heating fixtures and appliances. Observe ventilation and safety procedures specified in the MSDS. Do not store rubber surface products with materials that have a high capacity to adsorb volatile organic compound (VOC) emissions. Do not store exposed rubber surface materials in occupied spaces.

1.4 ENVIRONMENTAL REQUIREMENTS

Maintain areas to receive resilient flooring at a temperature above 68 degrees F and below 85 degrees F for 3 days before application, during application and 2 days after application, unless otherwise directed by the flooring manufacturer for the flooring being installed. Maintain a minimum temperature of 55 degrees F thereafter. Provide adequate ventilation to remove moisture from area and to comply with regulations limiting concentrations of hazardous vapors.

1.5 SCHEDULING

Schedule resilient application after the completion of other work which would damage the finished surface.

1.6 WARRANTY

Provide manufacturer's standard performance guarantees or warranties that extend beyond a one year period.

1.7 EXTRA MATERIALS

Provide extra wall base material composed of 20 linear feet of each type, color and pattern. Package all extra materials in original properly marked containers bearing the manufacturer's name, brand name, pattern color name and number, production run, and handling instructions. Provide extra materials from the same lot as those installed. Leave extra stock at the

SECTION 09 65 00 Page 2 site in location assigned by Contracting Officer.

PART 2 PRODUCTS

2.1 WALL BASE

Conform to ASTM F1861, Type TP (thermoplastic rubber) Style B (coved -installed with resilient flooring). Provide 4 inch high and a minimum 1/8 inch thick wall base. Provide job formed corners in matching height, shape, and color.

2.2 ADHESIVES

Provide adhesives for base and accessories as recommended by the manufacturer and comply with local indoor air quality standards. Submit manufacturer's descriptive data, documentation stating physical characteristics, and mildew and germicidal characteristics.

Provide non-aerosol adhesive products used on the interior of the building (defined as inside of the weatherproofing system) that meet either emissions requirements of CDPH SECTION 01350 (limit requirements for office spaces regardless of space type) or VOC content requirements of SCAQMD Rule 1168. Provide aerosol adhesives used on the interior of the building that meet either emissions requirements of CDPH SECTION 01350 (use the office or classroom requirements, regardless of space type) or VOC content requirements of GS-36. Provide certification or validation of indoor air quality for adhesives.

2.3 SURFACE PREPARATION MATERIALS

Provide surface preparation materials, such as floor crack fillers as recommended by the flooring manufacturer for the subfloor conditions.

2.4 FINISH

Provide finish as recommended by the manufacturer and conform to ASTM D4078 for polish.

2.5 CAULKING AND SEALANTS

Provide caulking and sealants in accordance with Section 07 92 00 JOINT

SEALANTS.

2.6 MANUFACTURER'S COLOR, PATTERN AND TEXTURE

Provide color, pattern and texture for accessories as indicated on the drawings selected from manufacturer's standard colors. Color listed is not intended to limit the selection of equal colors from other manufacturers.

Submit Data Package 1 in accordance with Section 01 78 23 OPERATION AND

MAINTENANCE DATA.

PART 3 EXECUTION

3.1 EXAMINATION

Examine and verify that site conditions are in agreement with the design package. Report all conditions that will prevent a proper installation.

Do not take any corrective action without written permission from the Government. Work will proceed only when conditions have been corrected and

SECTION 09 65 00 Page 3 accepted by the installer. Submit manufacturer's printed installation instructions for all flooring materials and accessories, including preparation of substrate, seaming techniques, and recommended adhesives.

3.2 GENERAL INSTALLATION

Do not install building construction materials that show visual evidence of biological growth.

3.3 CLEANING

Immediately upon completion of installation of wall base in a room or an area, dry and clean the adjacent surfaces to remove all surplus adhesive.

Clean as recommended in accordance with manufacturer's printed maintenance instructions and within the recommended time frame. As required by the manufacturer, apply the recommended number of coats and type of polish and finish in accordance with manufacturer's written instructions.

3.4 PROTECTION

From the time of installation until acceptance, protect from damage as recommended by the manufacturer. Remove and replace wall base which is not tight to wall or securely adhered.

SECTION 09 65 00 Page 4

SECTION 09 51 00

ACOUSTICAL CEILINGS

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM A489 (2018; E 2018) Standard Specification for Carbon Steel Eyebolts

ASTM A641/A641M (2009a; R 2014) Standard Specification for Zinc-Coated (Galvanized) Carbon Steel Wire

ASTM C635/C635M (2017) Standard Specification for Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-In Panel Ceilings

ASTM C636/C636M (2013) Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels

ASTM C834 (2017) Standard Specification for Latex Sealants

ASTM E580/E580M (2017) Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions

ASTM E795 (2016) Standard Practices for Mounting Test Specimens During Sound Absorption Tests

ASTM E1264 (2014) Acoustical Ceiling Products

ASTM E1414/E1414M (2011a; E 2014) Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling Plenum

ASTM E1477 (1998a; R 2017; E 2018) Standard Test Method for Luminous Reflectance Factor of Acoustical Materials by Use of Integrating-Sphere Reflectometers

CALIFORNIA DEPARTMENT OF PUBLIC HEALTH (CDPH)

CDPH SECTION 01350 (2010; Version 1.1) Standard Method for the Testing and Evaluation of Volatile

SECTION 09 51 00 Page 1

Organic Chemical Emissions from Indoor Sources using Environmental Chambers

SCIENTIFIC CERTIFICATION SYSTEMS (SCS)

SCS SCS Global Services (SCS) Indoor Advantage

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD)

SCAQMD Rule 1168 (2017) Adhesive and Sealant Applications

U.S. DEPARTMENT OF DEFENSE (DOD)

UFC 3-310-04 (2013; with Change 1, 2016) Seismic Design of Buildings

UNDERWRITERS LABORATORIES (UL)

UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00

SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Approved Detail Drawings; G

SD-03 Product Data

Acoustical Ceiling Systems; G

SD-04 Samples

Acoustical Ceiling Tiles; G

SD-06 Test Reports

Ceiling Attenuation Class and Test; G

1.3 CERTIFICATIONS

1.3.1 Indoor Air Quality Certifications

1.3.1.1 Ceiling Tiles

Provide products certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold or provide certification by other third-party programs. Provide current product certification documentation from certification body.

1.4 DELIVERY, STORAGE. AND HANDLING

Deliver materials to the site in the manufacturer's original unopened

SECTION 09 51 00 Page 2 containers with brand name and type clearly marked. Carefully handle and store materials in dry, watertight enclosures. Immediately before installation, store acoustical units for not less than 24 hours at the same temperature and relative humidity as the space where they will be installed in order to assure proper temperature and moisture acclimation.

1.5 ENVIRONMENTAL REQUIREMENTS

Maintain a uniform temperature of not less than 60 degrees F nor more than 85 degrees F and a relative humidity of not more than 70 percent for 24 hours before, during, and 24 hours after installation of acoustical units.

1.6 SCHEDULING

Complete and dry interior finish work such as plastering, concrete and terrazzo work before ceiling installation. Complete mechanical, electrical, and other work above the ceiling line; install and start operating heating, ventilating, and air conditioning systems in order to maintain temperature and humidity requirements.

1.7 WARRANTY

Provide manufacturer's standard performance guarantees or warranties that extend beyond a one…