Area X Structures Salient Characteristics 8-1-18 2018
1. Quantity: 44 modular structures with a 16’-0” bay width by 32’-0” in length (see figure 1)
(2) US Army graphic logo at entrance
(2) 3’-0” x 7’-0” Personnel Doors with Top Lite, Door Hardware & Closer for installation at each end of structure.
(2) Minimum 39” x 39” aluminum slider windows
(2) Framed openings for window AC unit.
All penetrations thru fabric will be sealed to prevent water intrusion.
2. Product must be delivered to Schofield Barracks Hawaii
3. Minimum 24 oz Fire Resistant, coated polyester fabric. PVC, Kynar, or Tedlar coated exterior, opaque membrane tension fabric structure. Exterior of structure including roof will be Pantone PMS 7526 C Brownstone Red. Interior liner will be white
4. Structure shall be completely clear span with no interior supports.
5. All main structural arches and connecting purlins shall be 100% Aluminum.
6. No exterior guy ropes or cables shall be used for anchoring the structure.
7. The structure shall be supplied with a complete insulation system (fiberglass blanket using formaldehyde free fiberglass insulation) within all roof and wall sections with a minimum R-value rating of R-25.
8. Structure must have corrosion resistant, structural aluminum frames, with concrete anchors.
9. All aluminum used in the structure shall carry a pro-rata guarantee of not less than 25 years.
10. Engineered stamped drawings will be provided with this contract
11. Interior must be capable of supporting light fixtures and duplex outlets with max load of 75 lbs. Electrical work including lighting and duplex electrical outlets will be supplied and installed on a separate contract
12. Both ends of structure will be flat walls.
13. White interior liner with exterior colors to match existing on site structures (see figure 2).
14. Structure will have vertical fabric walls of minimum height of 8’
15. Fabric roof of structure will be sloped for rain drainage.
16. Structure will be designed to meet 100 mph, Exposure C, 3 second gust as defined in ASCE-7-2005 and IBC-2009.
Note: A/C will be supplied by another contract. Opening in fabric will be supplied for the A/Cs
Figure 1 NOTE: Roof will be Brownstone Red, same as walls.