GSU_Transformer_Supply_Dwgs_W9128F19R0015.pdf

PDF 30 MB Posted

Attached to
Ft. Randall GSU Station Service Transformers
Solicitation number
W9128F19R0015
Issued by

About this file

Drawings

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

D R

A W

IN

G N

O

F

IL

E N

A M

E

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IC

T

W

IT

C H

Y A

R D

M

IS

S O

U R I

R

IV

E R

F O

R T R

A N

D A

L L D

A M A

N D R

S V

R

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

W E

R T

R A

N S

F O

R M

E R S

U P

P L

Y

V

IC

IN

IT

Y M

A P

S

P R

O J E

C T L

O C

A T

IO

N A

N D

C O

V E

R S

H E

E T

G-001

A N

S I

D

D F

IL

E R

D F

IL

E R

B

B O

U W

M A

N

FORT RANDALL DAM AND RESERVOIR

F R

F .0

G -0

.d g n

F R

F -5 .0

-0 -0 /1

W F -1

-R -0

SOLICITATION NUMBER: W9128F-19-R-0015

LOCATION

PROJECT

PROJECT PHOTO

PROJECT LOCATION MAP

PROJECT VICINITY MAP

FORT RANDALL DAM AND RESERVOIR

GENERATOR STEP-UP (GSU) TRANSFORMERS SUPPLY

90/120 MVA 230 KV GSU TRANSFORMERS (QTY. 3)

90/120 MVA 115 KV GSU TRANSFORMER (QTY. 1)

Omaha District of Engineers

US Army Corps

DATE: MAR 2019

M A

R

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

D R

A W

IN

G N

O

F

IL

E N

A M

E

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

P

R

T L

A N

D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IT

C H

Y A

R D

M

IS

S O

U R I

R

IV

E R

F O

R T R

A N

D A

L L D

A M A

N D R

S

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

W E

R T

R A

N S

F O

R M

E R S

U P

P L

Y

IN

D

E X O

F D

R A

W

IN

G S

A N

S I

D

D F

IL

E R

D F

IL

E R

B

B O

U W

M A

N

INDEX OF DRAWINGS

CONTRACT DRAWINGS

GENERAL

MECHANICAL

TITLE TITLESHEET NUMBER DRAWING NUMBER

REFERENCE DRAWINGS

FILE NUMBER

STRUCTURAL

ELECTRICAL - TRANSFORMER LAYOUTS

FRF7-5.001-0-0/6

FRF7-5.001-0-0/5

FRF7-5.001-0-0/4

FRF7-5.001-0-0/3

FRF7-5.001-0-0/2

FRF7-5.001-0-0/1

G-006

G-005

G-004

G-003

G-002

G-001

GSU TRANSFORMERS, CONCRETE PAD STEEL PLATES AND MOUNTING DETAILSFRF7-5.001-5-0/1S-101

ELECTRICAL - TRANSFORMER CONTROL SCHEMATICS AND PLANT INTERFACES

E-108

E-107

E-106

E-105

E-104

E-103

E-102

E-101

TRANSFORMER MOUNTED DEVICES, LAYOUT AND DETAILS

480 VAC POWER CABINET LAYOUT

CONTROL CABINET LAYOUT

POWER AND CONTROL CABINETS

MISCELLANEOUS DETAILS

GSU TRANSFORMERS, EQUIPMENT INSTALLATION AND LAYOUT ON MOUNTING PAD

GSU TRANSFORMERS, LAYOUT AND LIMITING DIMENSIONS, SHEET 2

GSU TRANSFORMERS, LAYOUT AND LIMITING DIMENSIONS, SHEET 1

G-002

E-607

E-606

E-605

E-604

E-603

E-602

E-601

SWITCHYARD STORAGE LOCATIONS AND STAGING

115 KV GSU TRANSFORMER, REQUIREMENTS SUMMARY SHEET

230 KV GSU TRANSFORMERS, REQUIREMENTS SUMMARY SHEET

SITE LOCATION PHOTOGRAPHS

INDEX OF DRAWINGS

COVER SHEET, PROJECT LOCATION AND VICINITY MAPS

CONTROL AND POWER CABINETS EXTERNAL CONNECTIONS

ANNUNCIATOR, FUNCTIONAL REQUIREMENTS, SHEET 2

ANNUNCIATOR, FUNCTIONAL REQUIREMENTS, SHEET 1

TRANSFORMER TEMPERATURE MONITOR, FUNCTIONAL REQUIREMENTS, SHEET 2

TRANSFORMER TEMPERATURE MONITOR, FUNCTIONAL REQUIREMENTS, SHEET 1

125VDC CONTROL SCHEMATIC

480 VAC COOLING AND CONTROL SCHEMATIC

F R

F .0

G -0

.d g n

F R

F -5 .0

-0 -0 /2

FRF7-5.001-6-9A4/4

FRF7-5.001-6-9A4/3

FRF7-5.001-6-9A4/2

FRF7-5.001-6-9A4/1

FRF7-5.001-6-9A40/4

FRF7-5.001-6-9A40/3

FRF7-5.001-6-9A40/2

FRF7-5.001-6-9A40/1

FRF7-5.001-6-9A24/7

FRF7-5.001-6-9A24/6

FRF7-5.001-6-9A24/5

FRF7-5.001-6-9A24/4

FRF7-5.001-6-9A24/3

FRF7-5.001-6-9A24/2

FRF7-5.001-6-9A24/1

MR-OPN-93E127

MR-OPN-93E126

MR-OPN-93E125

MR-OPN-83E303.10

MR6-84E56.9

MR6-84E55.7

MR6-83E811.4

MR6-83E803.4

MR6-83E802.3

MR6-83E801.3

MR6-83E800.4

MR6-83E227.5

MR6-83E221.7

MR6-83E206.2

MR6-83E205.4

MR6-81E801.7

MR6-81E450.5

MR6-81E436.3

MR6-81E427.3

MR6-81E426.2

MR6-81E401.8

MR6-81E400.7

230KV SWITCHYARD, TRANSFORMER BANK D, PLAN, SECTIONS & DETAILS

230KV SWITCHYARD, TRANSFORMER BANK C, PLAN, SECTIONS & DETAILS

230KV SWITCHYARD, TRANSFORMER BANK B, PLAN, SECTIONS & DETAILS

OPERATING DIAGRAM

SWITCHYARD ARCHITECTURAL, UNTANKING HOUSE, ELEVATIONS AND DETAILS

SWITCHYARD ARCHITECTURAL, UNTANKING HOUSE, PLANS AND SECTIONS

SWITCHYARD ELECTRICAL, UNITS 5 THRU 8, 230KV EQUIPMENT LAYOUT

SWITCHYARD ELECTRICAL, UNITS 5 THRU 8, EQUIPMENT LAYOUT

SWITCHYARD ELECTRICAL, UNITS 5 THRU 8, 230KV STRUCTURE - SECTIONS, SHEET 2

SWITCHYARD ELECTRICAL, UNITS 5 THRU 8, 230KV STRUCTURE - SECTIONS, SHEET 1

SWITCHYARD ELECTRICAL, UNITS 5 THRU 8, GENERAL PLAN

SWITCHYARD ELECTRICAL, GROUND NETWORK AND DETAILS

SWITCHYARD ELECTRICAL, POWER AND CONTROL CONDUIT, SHEET 1

SWITCHYARD ELECTRICAL, 115KV STRUCTURE SECTIONS, SHEET 2

SWITCHYARD ELECTRICAL, 115KV STRUCTURE SECTIONS, SHEET 1

SWITCHYARD, GENERAL FOUNDATION PLAN ADDITIONS, UNITS 5 TO 8 INCL.

SWITCHYARD SURFACING, DRAINAGE, TRANSFER TRACK AND FENCE PLAN

SWITCHYARD UNTANKING HOUSE, REINFORCEMENT, EL. 1272.75 FLOOR - PLAN

SWITCHYARD UNTANKING HOUSE, CONCRETE, SUPERSTRUCTURE WALLS, ELEVATIONS

SWITCHYARD UNTANKING HOUSE, CONCRETE, EL. 1272.75 FLOOR

SWITCHYARD CONCRETE, GENERAL FOUNDATION PLAN, SHEET 2

SWITCHYARD CONCRETE, GENERAL FOUNDATION PLAN, SHEET 1

W F -1

-R -0

M

R

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

D R

A W

IN

G N

O

F

IL

E N

A M

E

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

R

T L

A N

D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IT

C H

Y A

R D

M

IS

S O

U R I

R

IV

E R

F O

R T R

A N

D A

L L D

A M A

N D R

S

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

W E

R T

R A

N S

F O

R M

E R S

U P

P L

ENTRANCE TO FORT RANDALL DAM

POWERHOUSE ROAD

ENTRANCE TO FORT RANDALL DAM

POWERHOUSE ROAD

VIEW FROM PARKING LOT

TRANSFORMER UNTANKING HOUSE

ENTRANCE TO SWITCHYARD

TRANSFORMER UNTANKING HOUSE ACCESS GATE INTO SWITCHYARD

GSU TRANSFORMER BANK LAYOUT

TYPICAL EXISTING SINGLE-PHASE

VIEW FROM UNTANKING HOUSE EQUIPMENT DOOR

ACCESS CORRIDOR FOR TRANFORMER MOVEMENT

AND STORAGE AREA ADJACENT TO UNTANKING HOUSE

EXISTING BANK A 115 KV TRANSFORMERS

TRANSFORMER UNTANKING HOUSE

OVERHEAD BRIDGE CRANE INSIDE

S

IT

E L

O C

A T

IO

N P

H O

T O

G R

A P

H S

G-003

A N

S I

D

F R

F -5 .0

-0 -0 /3

D F

IL

E R

D F

IL

E R

B

B O

U W

M A

N

F R

F .0

G -0

.d g n

W F -1

-R -0

R

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

D R

A W

IN

G N

O

F

IL

E N

A M

E

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

R

T L

A N

D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IT

C H

Y A

R D

M

IS

S O

U R I

R

IV

E R

F O

R T R

A N

D A

L L D

A M A

N D R

S

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

W E

R T

R A

N S

F O

R M

E R S

U P

P L

Y

R E

Q U

IR

E M

E N

T S S

U M

M A

R Y S

H E

E T

K

V T

R A

N S

F O

R M

E R

S

A N

S I

D

D F

IL

E R

D F

IL

E R

B

B O

U W

M A

N

NAMEPLATE DATA:

TANK AND CONSTRUCTION:

ACCESSORIES:

BUSHINGS:

SURGE ARRESTERS:

INSULATING OIL:

SEPARATE CONTROL AND POWER CABINETS:

SPARE PARTS:

FACTORY ASSEMBLY AND PAINT:

FACTORY ACCEPTANCE TESTS (F.A.T.):

REQUIREMENTS SUMMARY SHEET

FORT RANDALL DAM 230 KV GSU TRANSFORMERS

(REFERENCE SPECIFICATION SECTION 48 19 23.04 26)

NAPTHENIC BASE - ASTM D 3487 TYPE II; 0.3% BY MASS OF OXIDATION INHIBITORTYPE:∙

(4) COMPLETELY ASSEMBLED AND WITNESSING OF FACTORY ACCEPTANCE TESTS

(3) COMPLETED CORE/COIL ASSEMBLY, BUT PRIOR TO TANKING

(2) AFTER COMPLETION OF WINDINGS BUT PRIOR TO LANDING ON CORE

(1) DESIGN REVIEW MEETING

GOVERNMENT INSPECTIONS PERFORMED DURINGINSPECTIONS:∙

FOR ONE WEEK PRIOR TO OIL FILLING.

PRIMER COAT, OIL-RESISTANT FINISH COAT - WHITE. ALLOW TO CUREINTERIOR PAINT:∙

CABINETS, SHALL REMAIN UNPAINTED. COVER TO RECEIVE A NON-SLIP COATING.

5BG 7/0.4 HIGH-GLOSS. CORROSION RESISTANT SURFACES, AND STAINLESS STEEL

PRIMER COAT, EPOXY BASE COAT, POLYURETHANE TOP COAT - MUNSELLEXTERIOR PAINT:∙

MATCH-MARKED FOR EASE OF REASSEMBLY.

TRANSFORMER TO BE FULLY ASSEMBLED, WITH REMOVABLE COMPONENTSASSEMBLY:∙

60 HZFREQUENCY:∙

200 KWMAXIMUM LOAD LOSSES:∙

100 KWMAXIMUM NO-LOAD LOSSES:∙

68 DBMAXIMUM SOUND LEVEL (ONAF):∙

CONSTANT OIL PRESSURE SYSTEM (COPS) TANKOIL PRESERVATION SYSTEM:∙

65 ºCTEMPERATURE RISE:∙

5 TAPS; 2 @ +2.5%, 2 @ -2.5% OF NOMINAL 230 KV TAPSECONDARY WINDING (H) DETC:∙

9.0% @ 90,000 KVA (H-X)IMPEDANCE:∙

THREE-PHASEPHASING:∙

825 (H) / 110 (X) / 150 (H0)BIL LEVELS, KV:∙

230,000 GRDY (H) - 13,800 DELTA (X)VOLTAGE RATINGS:∙

90,000 / 120,000KVA RATING:∙

ONAN/ONAFCOOLING CLASS:∙

CLASS II GSU POWER TRANSFORMERTYPE:∙

AT TRANSFORMER BASE.

THE DISCHARGE COUNTERS, AND FROM THE DISCHARGE COUNTERS TO A GROUND PAD

#4/0 AWG INSULATED GROUNDING CONDUCTORS FROM ARRESTERS TOGROUNDING:∙

48 19 23.04 26, PARAGRAPH 2.10.1)

OF THE EXISTING ARRESTERS (NAMEPLATE INFORMATION INCLUDED IN SECTION

REMOVABLE BRACKETS ON TOP OF TRANSFORMER, DESIGNED FOR MOUNTINGMOUNTING: ∙

∙ NO SURGE ARRESTERS TO BE PROVIDED (TO BE INSTALLED UNDER SEPARATE CONTRACT)

∙ ANALOG TEMPERATURE GAGE FUNCTIONAL VERIFICATION

∙ BUSHING CURRENT TRANSFORMER ROUTINE TESTS

AND POWER FACTOR TESTS DURING TRANSFORMER F.A.T.

∙ EACH HIGH-VOLTAGE AND HIGH-VOLTAGE NEUTRAL BUSHING SHALL UNDERGO CAPACITANCE

∙ ALL ELECTRICAL AND ELECTO-MECHANICAL DEVICES SHALL BE FUNCTIONALLY TESTED

∙ DE-ENERGIZED TAP CHANGER MECHANICAL OPERATIONAL TEST (5 COMPLETE CYCLES)

SHIPPING CONFIGURATION

- ONE SFRA TEST TO BE PERFORMED WITH THE TRANSFORMER IN THE

OIL FILLED

- ONE SFRA TEST TO BE PERFORMED WITH THE TRANSFORMER FULLY ASSEMBLED AND

- CABLE INTEGRITY TEST REQUIRED

∙ SWEEP FREQUENCY RESPONSE ANALYSIS (WITH ELECTRONIC DATA FILES)

∙ LEAKAGE REACTANCE (WITH ELECTRONIC DATA FILES)

ONE HOUR LEVEL: 300 PC

∙ INDUCED VOLTAGE TEST ACCEPTANCE CRITERIA: 7,200 CYCLE ENHANCEMENT LEVEL: 500 PC;

∙ AUDIBLE SOUND LEVEL TESTS SHALL BE PERFORMED ON ONE 230 KV TRANSFORMER

∙ LIGHTNING IMPULSE TESTS

230 KV TRANSFORMER

∙ TEMPERATURE RISE TESTS SHALL BE PERFORMED AT EACH COOLING STAGE ON ONE

∙ ALL 'ROUTINE' TESTS (IEEE C57.12.00, TABLE 17)

G-004

INSTALLATION OF ARRESTERS.

ARRESTER SUPPORTS AND GROUND CONDUCTORS FOR FUTUREARRESTER MOUNTS:∙

: VERTICAL-DRAFTCOOLING FANS∙

HOT-DIP GALVANIZED.RADIATORS:∙

STEEL. MAXIMUM DESIGN FLUX DENSITY OF 1.75 TESLA. STEP-LAP CONSTRUCTION.

LAMINATIONS MAXIMUM THICKNESS OF 0.270MM, COLD-ROLLED, GRAIN-ORIENTEDCORE:∙

SEISMIC CALCULATIONS REQUIRED FOR MAIN TANK AND ALL MAJOR COMPONENTS.SEISMIC:∙

DESIGN LOADS FOR EACH EYE SHALL BE TWO TIMES THE ACTUAL LOAD.LIFTING EYES:∙

DESIGNED FOR PAD MOUNTING WITH SEISMIC WELDING TO STEEL PLATES.BASE:∙

AND LOCKABLE LADDER GUARD, POWDER-COATED YELLOW.

FIXED STEEL LADDER WITH WALK-THRU HANDRAIL ACCESS, SAFETY CAGEACCESS LADDER:∙

POST.

DBI-SALA MODEL 8517412, DESIGNED FOR USE WITH THE DBI-SALA FALL ARREST ANCHOR

UNI-ANCHOR PLATE AND LUG,PORTABLE FALL ARREST ANCHOR POST MOUNTING PLATE: ∙

GROUND PAD AT BASE OF TANK.

#4/0 INSULATED COPPER CONDUCTOR FROM NEUTRAL BUSHING TO TANKGROUNDING:∙

STAINLESS STEEL BALL-TYPE (RADIATORS MAY USE BUTTERFLY-TYPE)VALVES:∙

BE USED FOR GASKET GROOVES OF RECTANGULAR CROSS-SECTION.

THAT THE LOW-VOLTAGE BUSHING GASKETS WILL BE VITON. O-RING GASKETS SHALL NOT

NITRILE NBR (BUNA-N), DURO 50-60, 25% COMPRESSION, WITH THE EXCEPTIONGASKETS:∙

24-INCH DIAMETER (MINIMUM TWO)MAN-HOLE:∙

230 KV TRANSFORMER SPECIFIC

COMMON FOR 230 KV AND 115 KV TRANSFORMERS

F R

F .0

G -0

.d g n

F R

F -5 .0

-0 -0 /4

∙ (QTY 1): BUSHING CURRENT TRANSFORMER OF EACH TYPE AND RATING

∙ (QTY 3): SET OF GASKETS FOR TRANSFORMER REASSEMBLY

∙ (QTY 1): COMPLETE GASKET SET

∙ (QTY 1): 25 KV HIGH-VOLTAGE NEUTRAL BUSHING

∙ (QTY 2): 230 KV HIGH-VOLTAGE WINDING BUSHING

∙ (QTY 1): VALVE OF EACH SIZE AND TYPE

∙ (QTY 1): FUSE OF EACH TYPE AND RATING

PLATE TO THE TRANSFORMER TEMPERATURE MONITOR FIBER-OPTIC MODULE

∙ (QTY 10): FIBER OPTIC EXTENSION CABLE THAT CONNECTS THE FEED-THROUGH WALL

∙ (QTY 3): COOLING FAN COMPLETE WITH MOTOR

∙ (QTY 1): GAS DETECTOR RELAY

∙ (QTY 1): OIL TEMPERATURE INDICATOR

∙ (QTY 1): WINDING TEMPERATURE INDICATOR

∙ (QTY 1): LIQUID LEVEL INDICATOR

∙ (QTY 1): TRANSFORMER TEMPERATURE MONITOR MODULE OF EACH TYPE

∙ (QTY 1): ELECTRONIC PRESSURE MONITOR AND TWO PRESSURE TRANSDUCERS

∙ (QTY 1): PRESSURE RELIEF DEVICE

∙ (QTY 1): RELAY AND CONTACTOR OF EACH TYPE AND RATING

∙ (QTY 1): ANNUNCIATOR

∙ (QTY 2): 25 KV LOW-VOLTAGE WINDING BUSHING

OR STAINLESS STEEL WITH ENGRAVED BLACK LETTERING.

NAMEPLATES WITHIN THE CONTROL AND POWER CABINETS SHALL BE ANODIZED ALUMINUM

LOW-VOLTAGE BUSHINGS MADE OF STAINLESS STEEL WITH BLACK LETTERING. DEVICE

EQUIPMENT NAMEPLATES SHALL BE PROVIDED FOR THE HIGH-VOLTAGE BUSHINGS AND

DIAGRAM NAMEPLATE FOR SLING LOCATIONS AND LIFT POSITIONS SHALL ALSO BE PROVIDED.

AND VACUUM THE TANK WILL WITHSTAND, AND CALCULATED X/R RATIO. AN ADDITIONAL

MANUFACTURING DATE, PLANT LOCATION, GOVERNMENT CONTRACT NUMBER, PRESSURE

CAST BRONZE OR STAINLESS STEEL; IEEE C57.12.00, TABLE 7, INCLUDINGNAMEPLATES:∙

- FOLD-DOWN MAINTENANCE TRAY ON INSIDE OF CONTROL CABINET DOOR.

GRADE HUMIDISTAT / THERMOSTAT CONTROL.

- PTC RESISTOR DESIGN ENCLOSURE HEATERS WITH INTEGRAL FANS, AND INDUSTRIAL

CABINET.

- 120 V AC, 20 A HOSPITAL GRADE GFCI RECEPTACLE MOUNTED INSIDE THE CONTROL

- 120 V AC, 1,000 LUMEN LED TYPE A19 LAMPS WITH DOOR-ACTUATED SWITCH.

IN POWER CABINET.

- ALL CIRCUITS, WIRING AND EQUIPMENT RATED GREATER THAN 120 V AC TO BE MOUNTED

PROVIDED IN CABINET DOOR FOR VIEWING.

ON SWING PANEL WITHIN CONTROL CABINET, WITH WEATHERPROOF WINDOW

- TRANSFORMER TEMPERATURE MONITOR (QUALITROL QTMS), WITH HMI MODULE MOUNTED

CABINET, WITH WEATHERPROOF WINDOW PROVIDED IN CABINET DOOR FOR VIEWING.

- TWO 10 PT. ANNUNCIATORS (SEL MODEL 2533) MOUNTED ON SWING PANEL WITHIN CONTROL

SERIES 24)

- LOCKOUT RELAY WITH TRIP COIL MONITORING AND INDICATORS (ELECTROSWITCH

SPECIAL FEATURES:∙

- 125 AND 250 V DC CIRCUITS - RATED 125/250 OR 250 V DC, AND 10,000 A INTERRUPTING

- 120 V AC CIRCUITS - RATED 250 V DC AND 120/240 OR 240 V AC, AND 10,000 A INTERRUPTING

- 480 V AC CIRCUITS - RATED 600 V AC AND 35,000 A INTERRUPTING AT 480 VAC

MOLDED-CASE CIRCUIT BREAKERS:∙

120 V AC CIRCUITS - 10 A

- SINGLE-BREAK INDUCTIVE LOAD INTERRUPTING RATING: 125 V DC CIRCUITS - 1.5 A;

- RATED FOR 600 V AC OR 250 V DC

SWITCHES:∙

120 V AC CIRCUITS - 6.0 A

- SINGLE-CONTACT INDUCTIVE LOAD INTERRUPTING CAPACITY: 125 V DC CIRCUITS - 1.0 A;

- RATED FOR 125 V DC OR 120 V AC; MEETS REQUIREMENTS OF NEMA ICS5; 10 A CONTACTS

AUXILIARY RELAYS:∙

600 V, 30 A MINIMUM, 90 ºC RATED TERMINATIONS.TERMINAL BLOCKS:∙

WITH CAST COVERS AND LIQUID-TIGHT HUBS.

JOINT COMPOUND APPLIED. OUTLET AND JUNCTION BOXES SHALL BE CAST ALUMINUM

CHANNELS NOT ALLOWED. ALL CONDUIT THREADED JOINTS SHALL HAVE A CONDUCTIVE

ALL WIRING TO BE RUN IN CONDUIT. WIRE RUNS THROUGH TANK REINFORCINGCONDUIT:∙

GROUND - GREEN/YELLOW

PHASE B - ORANGE; PHASE C - YELLOW; GROUNDED NEUTRAL - WHITE; INSULATED

XLPE; 3-PHASE POWER CONDUCTORS COLOR CODED: PHASE A - BROWN;WIRING:∙

POWER - 125 V DC; COOLING FANS - 480 V AC, 3-WIRE, 3-PHASE, 60 HZ

CONTROL POWER - 125 V DC; ANNUNCIATIONGOVERNMENT-FURNISHED POWER:∙

IN CONTROL CABINET. SOLAR SHIELDING ON TOP, FRONT AND SIDE PANELS OF ENCLOSURES.

PROVISIONS. WINDOWS FOR VIEWING THE TEMPERATURE MONITOR AND ANNUNCIATOR

WEATHER-PROOF TYPE 304 STAINLESS STEEL WITH LOCKINGCABINET MATERIAL:∙

(DBI-SALA, MODEL 8516691)

∙ PORTABLE FALL ARREST SYSTEM ANCHOR POST WITH DAVIT ARM

∙ MAINTENANCE-FREE DEHYDRATING BREATHER (MESSKO, MODEL DB200G GAMMA)

∙ ELECTRONIC PRESSURE MONITOR, WITH THREE SENSORS ON MAIN TANK (QUALITROL,MODEL 930)

WINDING TEMPERATURE MEASUREMENT (QUALITROL, MODEL QTMS)

∙ TRANSFORMER TEMPERATURE MONITOR WITH COOLING CONTROLS AND FIBER-OPTIC

∙ ON-LINE DISSOLVED GAS AND MOISTURE CONTENT MONITOR (SERVERON, MODEL TM8)

∙ DIRECTED-FLOW PRESSURE RELIEF DEVICE WITH METAL DISCHARGE PIPING (QUALITROL, MODEL XPRD)

∙ GAS DETECTOR RELAY ON TOP OF CONSERVATOR TANK (ABB, MODEL 12)

∙ OIL LEVEL INDICATOR ON CONSERVATOR TANK (MESSKO, MODEL MTO)

∙ WTI AND OTI GAUGES WITH RTDS (MESSKO TRASY2, MODEL MT-ST160)

2.5 KV CLASS, 45 KV BIL, 100 AMPSFRA TEST SHIPPING BUSHING:∙

2.5 KV CLASS, 45 KV BIL, 100 AMPCORE GROUNDS:∙

METERING ACCURACY, C400 MINIMUM RELAYING ACCURACY)

IMPREGNATED SYNTHETIC (RIS) CONDENSER CORE DESIGN (ONE 800:5 CT, 0.3B-1.8

25 KV CLASS, 200 KV BIL, 400 AMP, COMPOSITE EXTERIOR WITH RESIN-NEUTRAL (H0):∙

INDICATING EQUIPMENT OR TRANSFORMER TEMPERATURE MONITOR SYSTEM)

(BUSHING CURRENT TRANSFORMERS AS REQUIRED FOR THE WINDING TEMPERATURE

BULK-TYPE, LOW-CORONA, LIGHT CONTAMINATION, 125 ºC TEMPERATURE RISE RATING

25 KV CLASS, 150 KV BIL, 6,000 AMP, PORCELAIN CONSTRUCTION,PRIMARY WINDING (X):∙

0.3B-1.8 METERING ACCURACY, C400 RELAYING ACCURACY)

RESIN-IMPREGNATED SYNTHETIC (RIS) CONDENSER CORE DESIGN (TWO 600:5 MRCT,

230 KV CLASS, 900 KV BIL, 400 AMP, COMPOSITE EXTERIOR WITHSECONDARY WINDING (H):∙

W F -1

-R -0

R

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

D R

A W

IN

G N

O

F

IL

E N

A M

E

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

R

T L

A N

D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IT

C H

Y A

R D

M

IS

S O

U R I

R

IV

E R

F O

R T R

A N

D A

L L D

A M A

N D R

S

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

W E

R T

R A

N S

F O

R M

E R S

U P

P L

Y

R E

Q U

IR

E M

E N

T S S

U M

M A

R Y S

H E

E T

K

V G

S U T

R A

N S

F O

R M

E R

A N

S I

D

D F

IL

E R

D F

IL

E R

B

B O

U W

M A

N

NAMEPLATE DATA:

TANK AND CONSTRUCTION:

ACCESSORIES:

BUSHINGS:

SURGE ARRESTERS:

INSULATING OIL:

SEPARATE CONTROL AND POWER CABINETS:

FACTORY ASSEMBLY AND PAINT:

FACTORY ACCEPTANCE TESTS (F.A.T.):

(REFERENCE SPECIFICATION SECTION 48 19 23.04 26)

NAPTHENIC BASE - ASTM D 3487 TYPE II; 0.3% BY MASS OF OXIDATION INHIBITORTYPE:∙

(4) COMPLETELY ASSEMBLED AND WITNESSING OF FACTORY ACCEPTANCE TESTS

(3) COMPLETED CORE/COIL ASSEMBLY, BUT PRIOR TO TANKING

(2) AFTER COMPLETION OF WINDINGS BUT PRIOR TO LANDING ON CORE

(1) DESIGN REVIEW MEETING

GOVERNMENT INSPECTIONS PERFORMED DURINGINSPECTIONS:∙

FOR ONE WEEK PRIOR TO OIL FILLING.

PRIMER COAT, OIL-RESISTANT FINISH COAT - WHITE. ALLOW TO CUREINTERIOR PAINT:∙

CABINETS, SHALL REMAIN UNPAINTED. COVER TO RECEIVE A NON-SLIP COATING.

5BG 7/0.4 HIGH-GLOSS. CORROSION RESISTANT SURFACES, AND STAINLESS STEEL

PRIMER COAT, EPOXY BASE COAT, POLYURETHANE TOP COAT - MUNSELLEXTERIOR PAINT:∙

MATCH-MARKED FOR EASE OF REASSEMBLY.

TRANSFORMER TO BE FULLY ASSEMBLED, WITH REMOVABLE COMPONENTSASSEMBLY:∙

∙ ANALOG TEMPERATURE GAGE FUNCTIONAL VERIFICATION

∙ BUSHING CURRENT TRANSFORMER ROUTINE TESTS

AND POWER FACTOR TESTS DURING TRANSFORMER F.A.T.

∙ EACH HIGH-VOLTAGE AND HIGH-VOLTAGE NEUTRAL BUSHING SHALL UNDERGO CAPACITANCE

∙ ALL ELECTRICAL AND ELECTO-MECHANICAL DEVICES SHALL BE FUNCTIONALLY TESTED

∙ DE-ENERGIZED TAP CHANGER MECHANICAL OPERATIONAL TEST (5 COMPLETE CYCLES)

SHIPPING CONFIGURATION

OIL FILLED - ONE SFRA TEST TO BE PERFORMED WITH THE TRANSFORMER IN THE

- ONE SFRA TEST TO BE PERFORMED WITH THE TRANSFORMER FULLY ASSEMBLED AND

- CABLE INTEGRITY TEST REQUIRED

∙ SWEEP FREQUENCY RESPONSE ANALYSIS (WITH ELECTRONIC DATA FILES)

∙ LEAKAGE REACTANCE (WITH ELECTRONIC DATA FILES)

ONE HOUR LEVEL: 300 PC

∙ INDUCED VOLTAGE TEST ACCEPTANCE CRITERIA: 7,200 CYCLE ENHANCEMENT LEVEL: 500 PC;

∙ AUDIBLE SOUND LEVEL TESTS

∙ LIGHTNING IMPULSE TESTS

∙ TEMPERATURE RISE TESTS SHALL BE PERFORMED AT EACH COOLING STAGE

∙ ALL 'ROUTINE' TESTS (IEEE C57.12.00, TABLE 17)

REQUIREMENTS SUMMARY SHEET

FORT RANDALL DAM 115KV GSU TRANSFORMER

60 HZFREQUENCY:∙

200 KWMAXIMUM LOAD LOSSES:∙

60 KWMAXIMUM NO-LOAD LOSSES:∙

68 DBMAXIMUM SOUND LEVEL (ONAF):∙

CONSTANT OIL PRESSURE SYSTEM (COPS) TANKOIL PRESERVATION SYSTEM:∙

65 ºCTEMPERATURE RISE:∙

5 TAPS; 2 @ +2.5%, 2 @ -2.5% OF NOMINAL 115 KV TAPSECONDARY WINDING (H) DETC:∙

8.5% @ 90,000 KVA (H-X)IMPEDANCE:∙

THREE-PHASEPHASING:∙

550(H) / 110 (X) / 150 (H0)BIL LEVELS, KV:∙

115,000 GRDY (H) - 13,800 DELTA (X)VOLTAGE RATINGS:∙

90,000 / 120,000KVA RATING:∙

ONAN/ONAFCOOLING CLASS:∙

CLASS II GSU POWER TRANSFORMERTYPE:∙

AT TRANSFORMER BASE

THE DISCHARGE COUNTERS, AND FROM THE DISCHARGE COUNTERS TO A GROUND PAD

#4/0 AWG INSULATED GROUNDING CONDUCTORS FROM ARRESTERS TOGROUNDING:∙

48 19 23.04 26, PARAGRAPH 2.10.1)

OF THE EXISTING ARRESTERS (NAMEPLATE INFORMATION INCLUDED IN SECTION

REMOVABLE BRACKETS ON TOP OF TRANSFORMER, DESIGNED FOR MOUNTINGMOUNTING: ∙

∙ NO SURGE ARRESTERS TO BE PROVIDED (TO BE INSTALLED UNDER SEPARATE CONTRACT)

OR STAINLESS STEEL WITH ENGRAVED BLACK LETTERING.

NAMEPLATES WITHIN THE CONTROL AND POWER CABINETS SHALL BE ANODIZED ALUMINUM

LOW-VOLTAGE BUSHINGS MADE OF STAINLESS STEEL WITH BLACK LETTERING. DEVICE

EQUIPMENT NAMEPLATES SHALL BE PROVIDED FOR THE HIGH-VOLTAGE BUSHINGS AND

DIAGRAM NAMEPLATE FOR SLING LOCATIONS AND LIFT POSITIONS SHALL ALSO BE PROVIDED.

AND VACUUM THE TANK WILL WITHSTAND, AND CALCULATED X/R RATIO. AN ADDITIONAL

MANUFACTURING DATE, PLANT LOCATION, GOVERNMENT CONTRACT NUMBER, PRESSURE

CAST BRONZE OR STAINLESS STEEL; IEEE C57.12.00, TABLE 7, INCLUDINGNAMEPLATES:∙

- FOLD-DOWN MAINTENANCE TRAY ON INSIDE OF CONTROL CABINET DOOR.

HUMIDISTAT / THERMOSTAT CONTROL.

- PTC RESISTOR DESIGN ENCLOSURE HEATERS WITH INTEGRAL FANS, AND INDUSTRIAL GRADE

CABINET.

- 120 V AC, 20 A HOSPITAL GRADE GFCI RECEPTACLE MOUNTED INSIDE THE CONTROL

- 120 V AC, 1,000 LUMEN LED TYPE A19 LAMPS WITH DOOR-ACTUATED SWITCH.

IN POWER CABINET.

- ALL CIRCUITS, WIRING AND EQUIPMENT RATED GREATER THAN 120 V AC TO BE MOUNTED

PROVIDED IN CABINET DOOR FOR VIEWING.

ON SWING PANEL WITHIN CONTROL CABINET, WITH WEATHERPROOF WINDOW

- TRANSFORMER TEMPERATURE MONITOR (QUALITROL QTMS), WITH HMI MODULE MOUNTED

CABINET, WITH WEATHERPROOF WINDOW PROVIDED IN CABINET DOOR FOR VIEWING.

- TWO 10 PT. ANNUNCIATORS (SEL MODEL 2533) MOUNTED ON SWING PANEL WITHIN CONTROL

SERIES 24)

- LOCKOUT RELAY WITH TRIP COIL MONITORING AND INDICATORS (ELECTROSWITCH

SPECIAL FEATURES:∙

- 125 AND 250 V DC CIRCUITS - RATED 125/250 OR 250 V DC, AND 10,000 A INTERRUPTING

- 120 V AC CIRCUITS - RATED 250 V DC AND 120/240 OR 240 V AC, AND 10,000 A INTERRUPTING

- 480 V AC CIRCUITS - RATED 600 V AC AND 35,000 A INTERRUPTING AT 480 VAC.

MOLDED-CASE CIRCUIT BREAKERS:∙

120 V AC CIRCUITS - 10 A

- SINGLE-BREAK INDUCTIVE LOAD INTERRUPTING RATING: 125 V DC CIRCUITS - 1.5 A;

- RATED FOR 600 V AC OR 250 V DC

SWITCHES:∙

120 V AC CIRCUITS - 6.0 A

- SINGLE-CONTACT INDUCTIVE LOAD INTERRUPTING CAPACITY: 125 V DC CIRCUITS - 1.0 A;

- RATED FOR 125 V DC OR 120 V AC; MEETS REQUIREMENTS OF NEMA ICS5; 10 A CONTACTS

AUXILIARY RELAYS:∙

600 V, 30 A MINIMUM, 90 ºC RATED TERMINATIONS.TERMINAL BLOCKS:∙

WITH CAST COVERS AND LIQUID-TIGHT HUBS.

JOINT COMPOUND APPLIED. OUTLET AND JUNCTION BOXES SHALL BE CAST ALUMINUM

CHANNELS NOT ALLOWED. ALL CONDUIT THREADED JOINTS SHALL HAVE A CONDUCTIVE

ALL WIRING TO BE RUN IN CONDUIT. WIRE RUNS THROUGH TANK REINFORCINGCONDUIT:∙

GROUND - GREEN/YELLOW

PHASE B - ORANGY; PHASE C - YELLOW; GROUNDED NEUTRAL - WHITE; INSULATED

XLPE; 3-PHASE POWER CONDUCTORS COLOR CODED: PHASE A - BROWN;WIRING:∙

POWER - 125 V DC; COOLING FANS - 480 V AC, 3-WIRE, 3-PHASE, 60 HZ

CONTROL POWER - 125 V DC; ANNUNCIATIONGOVERNMENT-FURNISHED POWER:∙

IN CONTROL CABINET. SOLAR SHIELDING ON TOP, FRONT AND SIDE PANELS OF ENCLOSURES.

PROVISIONS. WINDOWS FOR VIEWING THE TEMPERATURE MONITOR AND ANNUNCIATOR

WEATHER-PROOF TYPE 304 STAINLESS STEEL WITH LOCKINGCABINET MATERIAL:∙

SPARE PARTS:

115 KV TRANSFORMER SPECIFIC

F R

F .0

G -0

.d g n

F R

F -5 .0

-0 -0 /5

G-005

COMMON FOR 230 KV AND 115 KV TRANSFORMERS

∙ (QTY 1): VALVE OF EACH SIZE AND TYPE

∙ (QTY 1): FUSE OF EACH TYPE AND RATING

PLATE TO THE TRANSFORMER TEMPERATURE MONITOR FIBER-OPTIC MODULE

∙ (QTY 10): FIBER OPTIC EXTENSION CABLE THAT CONNECTS THE FEED-THROUGH WALL

∙ (QTY 3): COOLING FAN COMPLETE WITH MOTOR

∙ (QTY 1): GAS DETECTOR RELAY

∙ (QTY 1): OIL TEMPERATURE INDICATOR

∙ (QTY 1): WINDING TEMPERATURE INDICATOR

∙ (QTY 1): LIQUID LEVEL INDICATOR

∙ (QTY 1): TRANSFORMER TEMPERATURE MONITOR MODULE OF EACH TYPE

∙ (QTY 1): ELECTRONIC PRESSURE MONITOR AND TWO PRESSURE TRANSDUCERS

∙ (QTY 1): PRESSURE RELIEF DEVICE

∙ (QTY 1): RELAY AND CONTACTOR OF EACH TYPE AND RATING

∙ (QTY 1): ANNUNCIATOR

∙ (QTY 2): 25 KV LOW-VOLTAGE WINDING BUSHING

∙ (QTY 1): BUSHING CURRENT TRANSFORMER OF EACH TYPE AND RATING

∙ (QTY 1): SET OF GASKETS FOR TRANSFORMER REASSEMBLY

∙ (QTY 1): COMPLETE GASKET SET

∙ (QTY 1): 25 KV HIGH-VOLTAGE NEUTRAL BUSHING

∙ (QTY 1): 138 KV HIGH-VOLTAGE WINDING BUSHING

INSTALLATION OF ARRESTERS.

ARRESTER SUPPORTS AND GROUND CONDUCTORS FOR FUTURE∙ ARRESTER MOUNTS:

VERTICAL-DRAFT∙ COOLING FANS:

HOT-DIP GALVANIZED.RADIATORS:∙

STEEL. MAXIMUM DESIGN FLUX DENSITY OF 1.75 TESLA. STEP-LAP CONSTRUCTION.

LAMINATIONS MAXIMUM THICKNESS OF 0.270MM, COLD-ROLLED, GRAIN-ORIENTEDCORE:∙

SEISMIC CALCULATIONS REQUIRED FOR MAIN TANK AND ALL MAJOR COMPONENTS.SEISMIC:∙

DESIGN LOADS FOR EACH EYE SHALL BE TWO TIMES THE ACTUAL LOAD.LIFTING EYES:∙

DESIGNED FOR PAD MOUNTING WITH SEISMIC WELDING TO STEEL PLATES.BASE:∙

AND LOCKABLE LADDER GUARD, POWDER-COATED YELLOW.

FIXED STEEL LADDER WITH WALK-THRU HANDRAIL ACCESS, SAFETY CAGE∙ ACCESS LADDER:

POST.

DBI-SALA MODEL 8517412, DESIGNED FOR USE WITH THE DBI-SALA FALL ARREST ANCHOR

UNI-ANCHOR PLATE AND LUG,PORTABLE FALL ARREST ANCHOR POST MOUNTING PLATE: ∙

GROUND PAD AT BASE OF TANK.

#4/0 INSULATED COPPER CONDUCTOR FROM NEUTRAL BUSHING TO TANKGROUNDING:∙

STAINLESS STEEL BALL-TYPE (RADIATORS MAY USE BUTTERFLY-TYPE)VALVES:∙

BE USED FOR GASKET GROOVES OF RECTANGULAR CROSS-SECTION.

THAT THE LOW-VOLTAGE BUSHING GASKETS WILL BE VITON. O-RING GASKETS SHALL NOT

NITRILE NBR (BUNA-N), DURO 50-60, 25% COMPRESSION, WITH THE EXCEPTIONGASKETS:∙

24-INCH DIAMETER (MINIMUM TWO)MAN-HOLE:∙

(DBI-SALA, MODEL 8516691)

∙ PORTABLE FALL ARREST SYSTEM ANCHOR POST WITH DAVIT ARM

∙ MAINTENANCE-FREE DEHYDRATING BREATHER (MESSKO, MODEL DB200G GAMMA)

∙ ELECTRONIC PRESSURE MONITOR, WITH THREE SENSORS ON MAIN TANK (QUALITROL, MODEL 930)

WINDING TEMPERATURE MEASUREMENT (QUALITROL, MODEL QTMS)

∙ TRANSFORMER TEMPERATURE MONITOR WITH COOLING CONTROLS AND FIBER-OPTIC

∙ ON-LINE DISSOLVED GAS AND MOISTURE CONTENT MONITOR (SERVERON, MODEL TM8)

∙ DIRECTED-FLOW PRESSURE RELIEF DEVICE WITH METAL DISCHARGE PIPING (QUALITROL, MODEL XPRD)

∙ GAS DETECTOR RELAY ON TOP OF CONSERVATOR TANK (ABB MODEL 12)

∙ OIL LEVEL INDICATOR ON CONSERVATOR TANK (MESSKO, MODEL MTO)

∙ WTI AND OTI GAUGES WITH RTDS (MESSKO TRASY2, MODEL MT-ST160)

2.5 KV CLASS, 45 KV BIL, 100 AMPSFRA TEST SHIPPING BUSHING:∙

2.5 KV CLASS, 45 KV BIL, 100 AMPCORE GROUNDS:∙

C400 RELAYING ACCURACY)

IMPREGNATED SYNTHETIC (RIS) CONDENSER CORE (ONE 800:5 CT, 0.3B-1.8 METERING ACCURACY, 25 KV CLASS, 200 KV BIL, 800 AMP, COMPOSITE EXTERIOR WITH RESIN-NEUTRAL (H0):∙

INDICATING EQUIPMENT OR TRANSFORMER TEMPERATURE MONITORING SYSTEM)

(BUSHING CURRENT TRANSFORMERS AS REQUIRED FOR THE WINDING TEMPERATURE

BULK-TYPE, LOW-CORONA, LIGHT CONTAMINATION, 125 ºC TEMPERATURE RISE RATING

25 KV CLASS, 150 KV BIL, 6,000 AMP, PORCELAIN CONSTRUCTION,PRIMARY WINDING (X):∙

ACCURACY, C400 RELAYING ACCURACY)

RESIN-IMPREGNATED SYNTHETIC (RIS) CONDENSER CORE (TWO 1200:5 MRCT, 0.3B-1.8 METERING

138 KV CLASS, 650 KV BIL, 800 AMP, COMPOSITE EXTERIOR WITHSECONDARY WINDING (H):∙

W F -1

-R -0

R

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

D R

A W

IN

G N

O

F

IL

E N

A M

E

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

R

T L

A N

D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IT

C H

Y A

R D

M

IS

S O

U R I

R

IV

E R

F O

R T R

A N

D A

L L D

A M A

N D R

S

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

W E

R T

R A

N S

F O

R M

E R S

U P

P

(APPROX. 25'x25')

STORAGE AREA

ACCESSORY CRATE

NOTES:

REASSEMBLY AND MOVEMENT, AND FOR STAGING PURPOSES.

TEMPORARY STORAGE OF MATERIALS DURING TRANSFORMER SITE

THE LOCATION AS INDICATED MAY BE USED BY THE CONTRACTOR FOR1.

A N

D S

T A

G

IN

G

S W

IT

C H

Y A

R D S

T O

R A

G E L

O C

A T

IO

N S

G-006

A N

S I

D

D F

IL

E R

D F

IL

E R

B

B O

U W

M A

N

W F -1

-R -0

F R

F .0

G -0

.d g n

F -5 .0

-0 -0 /6

M A

R

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

D R

A W

IN

G N

O

F

IL

E N

A M

E

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IT

C H

Y A

R D

M

IS

S O

U R I

R

IV

E R

F O

R T R

A N

D A

L L D

A M A

N D R

S

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

W E

R T

R A

N S

F O

R M

E R S

U P

P

SEGMENT

3 HIGH-VOLTAGE (H) BUSHING

NOTES:

QTY

BILL OF MATERIALS

ITEM DESCRIPTION

JACK PAD (TYPICAL)

3-INCH VACUUM VALVE

BRACKETS FOR WELDING BASE TO PAD (SHEET S-101)

RADIATOR (TYPICAL)

ANALOG TEMPERATURE GAUGES

RADIATOR ISOLATION VALVE

LIFTING EYE (TYPICAL)

SKID-TYPE STRUCTURAL BASE

HIGH-VOLTAGE NEUTRAL (H0) BUSHING

LOW-VOLTAGE (X) BUSHING

SURGE ARRESTER MOUNTING BRACKET

CONSTANT OIL PRESSURE SYSTEM (COPS) TANK

3 - COVER

2 - COVER

1 - COVER

OIL LEVEL INDICATOR

AS DES.

AS DES.

CONTROL CABINET

AS DES. THERMOWELLS

AS DES. TRANSFORMER NAMEPLATE LOCATION1

COVER

3-INCH MAIN OIL DRAIN VALVE

COVER

1-INCH COPS TANK DRAIN VALVE

1.5-INCH ELECTRONIC PRESSURE MONITOR SENSORS VALVE

GAS-IN-OIL MONITORING EQUIPMENT MOUNTING UNISTRUTAS DES.

1,3

1,3

1,2,3,4

6 1 3 SURGE ARRESTER DISCHARGE COUNTER

ELEVATION - SEGMENT 1

NOT TO SCALE

NOT TO SCALE

PLAN - COVER

(SEE NOTE 7)

S

E E N

O T

E

M A

X

375" (MAX.)

BUSHING SIDE)

(HIGH-VOLTAGE

SEGMENT 3

SEGMENT 2 SEGMENT 4

BUSHING SIDE)

(LOW-VOLTAGE

SEGMENT 1

FIGURE 1

IDENTIFICATION (TOP VIEW)

TRANSFORMER TANK SEGMENT

264" (MAX.)

BRAND NAME OR EQUAL MODEL NUMBER

1 POWER CABINET

29 1

30 2-INCH GAS-IN-OIL MONITOR VALVE

33 1, COVER

25 26

30 21

G S

U T

R A

N S

F O

R M

E R

L A

Y O

U T A

N D L

IM

IT

IN

G D

IM

E N

S

IO

N S

S H

E E

T

B

B O

U W

M A

N

D F

IL

E R

D F

IL

E R

A N

S I

D

F R

F -5 .0

-6 -9

A /1

MOSER GLASER

MOSER GLASER

ABB

QUALITROL XPRD

SERVERON TM8

930QUALITROLELECTRONIC PRESSURE MONITOR

GAS-IN-OIL MONITORING EQUIPMENT

PRESSURE RELIEF DEVICE WITH DISCHARGE PIPING

FIXED LADDER WITH SAFETY CAGE AND LOCKABLE LADDER GUARD

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

COTTERMAN TYPE FWC

SERIES MTO

H2 H3

X1 X2 X3

H1

X1

H1

X2 X3

H3H2

SURGE ARRESTER (NOTE 6)

NORMANDY MACHINE CO. 82-8001

TYPE LCRJ

BOWTHORPE TYPE SC13

TRAVESCA, TYPE RIS

TRAVESCA, TYPE RIS

114 1 MAINTENANCE-FREE DEHYDRATING BREATHER1

M A

X

IM

U M

NOTES:

35 AS DES. COVER MANHOLE ACCESS COVER

45 AS DES. COVER FALL ARREST SYSTEM MOUNTING BASE DBI-SALA 854712

24"24"

2-INCH LOWER FILTER VALVE

2-INCH UPPER FILTER VALVE

36 1 3 LOW-VOLTAGE BUSHING HANDHOLE ACCESS COVER

L(TANK)C

L C

MESSKO TRASY2, SERIES MT-ST160

MESSKO

MESSKO MTRAB, DB200G

47 COVER1 GAS DETECTOR RELAY ABB MODEL 12

E-101

F R

F .0

E -1

.d g n

RECOMMENDED BY THE DEVICE MANUFACTURER.

QUALTROL THREE-PORT TRANSDUCER MANIFOLD, IN A LOCATION AS

SHALL BE INSTALLED ON A fLANGED VALVE ON THE TANK UTILIZING A

A TOTAL OF THREE ELECTRONIC PRESSURE MONITOR TRANSDUCERS5.

INDICATE THE ACTUAL QUANTITY OF RADIATORS OR FANS.

THE DIRECTION OF FAN AIR FLOW, AND ARE NOT INTENDED TO

THE RADIATORS AS DEPICTED INDICATE THE PERMISSIBLE LOCATIONS AND4.

HAVE BEEN INDICATED WITH DASHED LINES.

FOR THE PURPOSES OF DRAWING CLARITY, SOME EQUIPMENT LOCATIONS3.

F. JACKING PADS AND STRUCTURAL BASE CHANNELS

E. ANCILLARY DEVICES

D. CONTROL AND POWER CABINETS

C. COPS TANK

B. SURGE ARRESTERS

A. HIGH-VOLTAGE AND LOW-VOLTAGE BUSHINGS

CONSIDERED CRITICAL TO ASSURE PROPER INTERCONNECTION:

THE LOCATIONS OF THE FOLLOWING ANCILLARY EQUIPMENT ARE

APPLICABLE TO BOTH THE 115 KV AND 230 KV TRANSFORMER DESIGNS.

POWER PLANT. THE LIMITING DIM ENSIONS INDICATED ARE

TRANSFORMERS FOR PROPER INTERCONNECTION TO THE EXISTING

PROVIDED FOR THE MANUFACTURER'S USE IN DESIGNING THE

THE TRANSFORMER LAYOUT AND LIMITING DIMENSIONS HAVE BEEN2.

INDICATED.

230 KV TRANSFORMER DESIGNS, UNLESS OTHERWISE SPECIFICALLY

ALL ASPECTS OF THIS DRAWING ARE APPLICABLE TO BOTH THE 115 KV AND1.

CENTERLINE OF THE ACCESS DOOR.

DOOR, WITH THE CENTERLINE OF THE TANK ALIGNED WITH THE

TRANSFORMER THROUGH THE UNTANKING HOUSE ACCESS

TRANSFORMER IS TO ALLOW MOVEMENT OF THE

THE MAXIMUM ALLOWABLE WIDTH OF THE ASSEMBLED8.

TAKEOFF TOWER SUPPORT COLUMNS.

PERMANENT LOCATION MOUNTING PAD, BETWEEN THE

OF THE TRANSFORMER FROM THE UNTANKING HOUSE TO THE

ASSOCIATED MOUNTING BRACKETS, IS TO ALLOW MOVEMENT

TRANSFORMER, NOT INCLUDING THE CONSERVATOR TANK AND

THE MAXIMUM ALLOWABLE LENGTH OF THE ASSEMBLED7.

ARRESTER MOUNTS.

SHALL BE PROVIDED AND COORDINATED WITH THE SURGE

HARDWARE, INSULATING SUB-BASES AND GROUND CONDUCTORS

CONTRACTOR. THE MOUNTING BRACKETS, MOUNTING

BE REUSED AND INSTALLED BY THE SEPARATE INSTALLATIONS

SPECIFICATIONS SECTION 48 19 23.04 26, PARAGRAPH 2.10) WILL

EXISTING INSTALLED POWER TRANSFORMERS (SEE

THE SURGE ARRESTERS WHICH ARE PRESENTLY IN USE ON THE6.

GAS-IN-OIL MONITORING EQUIPMENT HELIUM CYLINDER

CORE & CORE FRAME GROUND BUSHINGS (SEE SHEET E-103)

W F -1

-R -0

R

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

D R

A W

IN

G N

O

F

IL

E N

A M

E

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IT

C H

Y A

R D

M

IS

S O

U R I

R

IV

E R

F O

R T R

A N

D A

L L D

A M A

N D R

S

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

W E

R T

R A

N S

F O

R M

E R S

U P

P L

Y

S H

E E

T

L A

Y O

U T A

N D L

IM

IT

IN

G D

IM

E N

S

IO

N S

G S

U T

R A

N S

F O

R M

E R

E-102

A N

S I

D

F R

F -5 .0

-6 -9

A /2

D F

IL

E R

D F

IL

E R

B

B O

U W

M A

N

SEGMENT

3 HIGH-VOLTAGE (H) BUSHING

NOTES:

QTY

BILL OF MATERIALS

ITEM DESCRIPTION

JACK PAD (TYPICAL)

3-INCH VACUUM VALVE

BRACKETS FOR WELDING BASE TO PAD (SHEET S-101)

RADIATOR (TYPICAL)

RADIATOR ISOLATION VALVE

LIFTING EYE (TYPICAL)

SKID-TYPE STRUCTURAL BASE

HIGH-VOLTAGE NEUTRAL (H0) BUSHING

LOW-VOLTAGE (X) BUSHING

SURGE ARRESTER MOUNTING BRACKET

CONSTANT OIL PRESSURE SYSTEM (COPS) TANK

3 - COVER

2 - COVER

1 - COVER

OIL LEVEL INDICATOR

AS DES.

AS DES.

CONTROL CABINET

3-INCH MAIN OIL DRAIN VALVE

COVER

1-INCH COPS TANK DRAIN VALVE

1.5-INCH ELECTRONIC PRESSURE MONITOR SENSORS VALVE

1,3

1,3

1,2,3,4

SURGE ARRESTER (GOVERNMENT FURNISHED EQUIPMENT) (NOTE 5)

FIGURE 1

IDENTIFICATION (TOP VIEW)

TRANSFORMER TANK SEGMENT

BRAND NAME OR EQUAL MODEL NUMBER

1 POWER CABINET

29 1

30 2-INCH GAS-IN-OIL MONITOR VALVE

33 1, COVER

MOSER GLASER

MOSER GLASER

ABB

QUALITROL XPRDPRESSURE RELIEF DEVICE WITH DISCHARGE PIPING

FIXED LADDER WITH SAFETY CAGE AND LOCKABLE LADDER GUARD

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

MILWAUKEE VALVE F20SS, CLASS 150

COTTERMAN TYPE FWC

QUALITROL SERIES 042

ELEVATION - SEGMENT 2

NOT TO SCALE

ELEVATION - SEGMENT 4

NOT TO SCALE

ELEVATION - SEGMENT 3

NOT TO SCALE

AS DES.10 3 VERTICAL DRAFT COOLING FAN

10 9

KRENZ-VENT SERIES F26

114 2 MAINTENANCE FREE DEHYDRATING BREATHER QUALITROL STB-100

14 1617

16 17

30 31

1 DETC HANDWHEEL

BUSHING SIDE)

(HIGH-VOLTAGE

SEGMENT 3

BUSHING SIDE)

(LOW-VOLTAGE

SEGMENT 1

SEGMENT 4 SEGMENT 2

TYPE LCRJ

TRAVESCA, TYPE RIS

TRAVESCA, TYPE RIS

40 1 4 DETC CONTACTS HANDHOLE ACCESS COVER

16 6 SURGE ARRESTER DISCHARGE COUNTERS BOWTHORPE SC13

46 1

2-INCH LOWER FILTER VALVE

2-INCH UPPER FILTER VALVE

2 AUXILIARY POWER TRANSFORMER DONGAN SERIES ES-11

47 1 COVER GAS DETECTOR RELAY ABB MODEL 12

F R

F .0

E -1

.d g n

GAS-IN-OIL MONITORING EQUIPMENT HELIUM CYLINDER

THE SURGE ARRESTER MOUNTS.

GROUND CONDUCTORS SHALL BE PROVIDED AND COORDINATED WITH

BRACKETS, MOUNTING HARDWARE, INSULATING SUB-BASES AND

THE SEPARATE INSTALLATIONS CONTRACTOR. THE MOUNTING

48 19 23.04 26, PARAGRAPH 2.10) WILL BE REUSED AND INSTALLED BY

INSTALLED POWER TRANSFORMERS (SEE SPECIFICATIONS SECTION

THE SURGE ARRESTERS WHICH ARE PRESENTLY IN USE ON THE EXISTING5.

INDICATE THE ACTUAL QUANTITY OF RADIATORS OR FANS.

THE DIRECTION OF FAN AIR FLOW, AND ARE NOT INTENDED TO

THE RADIATORS AS DEPICTED INDICATE THE PERMISSIBLE LOCATIONS AND4.

HAVE BEEN INDICATED WITH DASHED LINES.

FOR THE PURPOSES OF DRAWING CLARITY, SOME EQUIPMENT LOCATIONS3.

F. JACKING PADS AND STRUCTURAL BASE CHANNELS

E. ANCILLARY DEVICES

D. CONTROL AND POWER CABINETS

C. COPS TANK

B. SURGE ARRESTERS

A. HIGH-VOLTAGE AND LOW-VOLTAGE BUSHINGS

INTERCONNECTION:

EQUIPMENT ARE CONSIDERED CRITICAL TO ASSURE PROPER

POWER PLANT. THE LOCATIONS OF THE FOLLOWING ANCILLARY

TRANSFORMERS FOR PROPER INTERCONNECTION TO THE EXISTING

PROVIDED FOR THE MANUFACTURER'S USE IN DESIGNING THE

THE TRANSFORMER LAYOUT AND LIMITING DIMENSIONS HAVE BEEN2.

INDICATED.

230 KV TRANSFORMER DESIGNS, UNLESS OTHERWISE SPECIFICALLY

ALL ASPECTS OF THIS DRAWING ARE APPLICABLE TO BOTH THE 115 KV AND1.

W F -1

-R -0

R

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

D R

A W

IN

G N

O

F

IL

E N

A M

E

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

E

P O

R T

L A

N D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IT

C H

Y A

R D

M

IS

S O

U R I

R

IV

E R

F O

R T R

A N

D A

L L D

A M A

N D R

S

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

W E

R T

R A

N S

F O

R M

E R S

U P

P L

Y

L A

Y O

U T O

N M

O U

N T

IN

G P

A D

E Q

U

IP

M E

N T I

N S

T A

L L

A T

IO

N A

N D

G S

U T

R A

N S

F O

R M

E R

S

E-103

A N

S I

D

F R

F -5 .0

-6 -9

A /3

D F

IL

E R

D F

IL

E R

B

B O

U W

M A

N

SUPPORT STRUCTURE

LOW-VOLTAGE BUS AND

C/L TRANSFORMER

TAKEOFF TOWER COLUMNS

C/L

12"

TOWER STRUCTURE

TOWER STRUCTURE

SWITCHYARD AUXILIARY BUS

A-PHASE

B-PHASE

C-PHASE

PLAN VIEW

PLACEMENT ON NEW MOUNTING PAD

TYPICAL EQUIPMENT INSTALLATION AND

THREE-PHASE GSU TRANSFORMER BANK

MOUNTING PAD

TRANSFORMER

NEW THREE-PHASE

CONDUCTOR (TYPICAL)

1000 KCMIL HIGH-VOLTAGE

SYSTEM (ESTIMATED)

NEW OIL CONTAINMENT

NOTES:

CONTRACTOR.

PADS SHALL BE COORDINATED WITH THE SEPARATE INSTALLATIONS

POSITIONING OF EACH NEW GSU TRANSFORMER ON THE NEW MOUNTING3.

SEPARATE INSTALLATIONS CONTRACTOR.

TRANSFORMERS TO THE POWER PLANT WILL BE PERFORMED BY A

VOLTAGE BUS STRUCTURE, AND ALL INTERCONNECTIONS FROM THE NEW

THE NEW MOUNTING PAD, MODIFICATIONS TO THE EXISTING LOW-2.

LAYOUT OF THE 115 KV TRANSFORMER BANK A IS SIMILAR.

IS FOR THE 230 KV GSU TRANSFORMER BANKS B, C AND D, AND THE

ON THEIR NEW MOUNTING PADS. THE LAYOUT SHOWN ON THIS DRAWING

REPLACEMENT THREE-PHASE GSU TRANSFORMERS AFTER PLACEMENT

THIS DRAWING SHOWS THE INTENDED LAYOUT AND POSITIONING OF THE1.

F R

F .0

E -1

.d g n

W F -1

-R -0

R

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

D R

A W

IN

G N

O

F

IL

E N

A M

E

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

R

T L

A N

D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IT

C H

Y A

R D

M

IS

S O

U R I

R

IV

E R

F O

R T R

A N

D A

L L D

A M A

N D R

S

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

W E

R T

R A

N S

F O

R M

E R S

U P

P L

Y

(#4 AWG)

GROUNDING CABLE

BUSHING

CORE GROUND

GROUND BUSHING

CORE FRAME

TANK COVER

(#4 AWG)

GROUNDING CABLE

TANK COVER

CORE FRAME

H2

H1 H3

X1

X2

X3

H0

CORE

PROTECTIVE COVER

M

IS

C E

L L

A N

E O

U S D

E T

A

IL

S

G S

U T

R A

N S

F O

R M

E R

S

E-104

A N

S I

D

F R

F -5 .0

-6 -9

A /4

D F

IL

E R

D F

IL

E R

B

B O

U W

M A

N

NOTES:

AND CORE FRAME GROUND BUSHINGS.

SEE SHEET 101, PLAN VIEW OF THE COVER, ITEM 7 FOR LOCATION OF THE CORE2.

TRANSFORMER DESIGNS, UNLESS OTHERWISE SPECIFICALLY INDICATED.

ALL ASPECTS OF THIS DRAWING ARE APPLICABLE TO BOTH THE 115 KV AND 230 KV1.

F R

F .0

E -1

.d g n

FIGURE 1

CORE AND CORE FRAME GROUNDING

VOLTAGE - PHASOR DIAGRAM

GSU TRANSFORMERS

W F -1

-R -0

R

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

D R

A W

IN

G N

O

F

IL

E N

A M

E

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

R

T L

A N

D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IT

C H

Y A

R D

M

IS

S O

U R I

R

IV

E R

F O

R T R

A N

D A

L L D

A M A

N D R

S

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

W E

R T

R A

N S

F O

R M

E R S

U P

P L

Y

D F

IL

E R

B

B O

U W

M

LEGEND:

NOTES:

SIDE VIEW

DETAIL OF VIBRATION ISOLATION MOUNTSPOWER AND CONTROL CABINETS

CABINET DOOR SEAL

DETAIL OF TYPICAL

CONNECTIONS AND GROUNDING

DETAIL OF ENCLOSURE CONDUIT

WINDOWS SEAL

TYPICAL CLAYTONRITE-TYPE

DETAIL "A"

CABINETS

POWER AND CONTROL

120 VAC & 125 VDC CONTROL CABINET480 VAC POWER CABINET

43TF 86T

TTM

TO POWER PLANT

CONNECTIONS

EXTERNAL CONDUIT

FUTURE

DOOR)

(INSIDE CABINET

DRAWING POCKET

O&M MANUAL

DOOR)

(INSIDE CABINET

COMPUTER TRAY

FOLD-DOWN

TERMINAL BOX

TO GAS-IN-OIL MONITOR

FRAMEWORK

CABINET MOUNTING

(SEE DETAIL 'A')

WINDOW SEAL

MOUNTS (TYPICAL)

VIBRATION ISOLATION

SIDEWALL

TRANSFORMER TANK

TEMPERED GLASS

RUBBER SEAL

ENCLOSURE PANEL

SECURING STRIP

DRIP SHIELD

RAIN AND

GASKET SEAL

DRIP CHANNEL

CABINET DOOR

SOLAR SHIELDING

GROUND WIRE

AND GROUNDING SCREW

WITH A CAPTIVE O-RING GASKET

SHALL BE A MYERS SCRU-TITE

ALL CONDUIT HUB FITTINGS

EQUIPMENT ENCLOSURE

C O

N T

R O

L C

A B

IN

E T S

P O

W E

R A

N D

E-105

A N

S I

D

D F

IL

E R

TRANSFORMER TEMPERATURE MONITORTTM

LOCKOUT RELAY86T

COOLING GROUP ON-OFF-AUTO SELECTOR SWITCH43TF

TRANSFORMER TEMPERATURE MONITOR30

SHALL HAVE A POCKET SIZED TO HOLD THE O&M MANUAL DRAWINGS.

AND A MEANS FOR LATCHING THE TRAY WHEN STOWED. THE LEFT DOOR

WHICH SECURE THE TRAY IN A HORIZONTAL POSITION WHEN LOWERED,

THE INSIDE OF THE DOOR. THE TRAY SHALL INCLUDE FOLDING HINGES

THE RIGHT DOOR SHALL HAVE A DROP DOWN LAPTOP TRAY MOUNTED ON8.

VIBRATION ISOLATORS.

STRUCTURE WHICH IS MOUNTED TO THE TRANSFORMER TANK USING

THE CONTROL AND POWER CABINETS SHALL BE MOUNTED TO A FRAME7.

APPROXIMATELY 60 INCHES ABOVE THE BASE OF THE TRANSFORMER.

MOUNTED ON THE SWING PANELS SO THAT THE DEVICES ARE

THE TRANSFORMER TEMPERATURE MONITOR AND ANNUNCIATOR SHALL BE6.

THROUGH THE BASE.

CONTROL AND POWER CABINETS SHALL ONLY ENTER EACH CABINET

ALL CONDUIT ROUTING FROM THE TRANSFORMER DEVICES TO THE5.

PLATES FOR THE PURPOSES OF FIELD FITTING OF CONDUIT.

VARY. THE BASE OF EACH CABINET SHALL HAVE GASKETED REMOVABLE

REPRESENTATIVE PURPOSES ONLY. ACTUAL QUANTITIES AND SIZES MAY

EXTERNAL CONDUIT CONNECTIONS TO THE POWER PLANT ARE SHOWN FOR4.

SPACE FOR ARC FLASH LABEL (PROVIDED BY THE GOVERNMENT).3.

AND BUILT IN ACCORDANCE WITH UL STANDARD 508A.

THE TRANSFORMER CONTROL AND POWER CABINTES ARE TO BE DESIGNED2.

INDICATED.

230 KV TRANSFORMER DESIGNS, UNLESS OTHERWISE SPECIFICALLY

ALL ASPECTS OF THIS DRAWING ARE APPLICABLE TO BOTH THE 115 KV AND1.

SEE NOTE 3

F R

F .0

E -1

.d g n

F R

F -5 .0

-6 -9

A /1

W F -1

-R -0

R

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

D R

A W

IN

G N

O

F

IL

E N

A M

E

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

R

T L

A N

D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IT

C H

Y A

R D

M

IS

S O

U R I

R

IV

E R

F O

R T R

A N

D A

L L D

A M A

N D R

S

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

W E

R T

R A

N S

F O

R M

E R S

U P

P L

Y

C O

N T

R O

L C

A B

IN

E T

E-106

A N

S I

D

D F

IL

E R

D F

IL

E R

B

B O

U W

M A

N

DESCRIPTION BRAND NAME OR EQUAL MODEL NUMBER

QUALITROL QTMS

MOLDED-CASE CIRCUIT BREAKERS

AUXILIARY RELAYS

INTERPOSING RELAY FOR LOCKOUT RELAY GENERAL ELECTRIC

LOCKOUT RELAY ELECTROSWITCH SERIES 24, MODEL 78PB02E

TERMINAL BLOCKS - CONTROL SIGNAL TYPE

TERMINAL BLOCKS - POWER DISTRIBUTION TYPE

FUSES

FUSE HOLDERS

CABINET HEATER

ELECTROSWITCH SERIES 24

UNDERVOLTAGE RELAY

RECEPTACLE WITH GROUND FAULT HUBBELL GFR8300SGW

MARATHON SERIES 142

TIME MARK

BUSSMAN

BUSSMAN

WAUKESHA PTC2

FAL

C26(XX)

HMA

LPJ

JTN600(XX)

TIME DELAY RELAY AGASTAT SERIES 7000

TRANSFORMER TEMPERATURE MONITOR

LOCAL ANNUNCIATOR PANELS (DEVICE 30) SEL 2533

ITEM

COOLING GROUP SELECTOR SW. (DEVICE 43TF)

TERMINAL BLOCKS - SHORT CIRCUIT

GROUND BUS BAR - -

QTY

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

NOTES:

LH BACK PANEL RH BACK PANEL RH SIDE PANEL

(FRONT VIEW)

RIGHT SWING PANEL

BLOCKS

TERMINAL

RESISTORS

CALIBRATION

ANALOG WTI

BLOCKS

TERMINAL

BLOCKS

TERMINAL

BLOCKS

TERMINAL

TRANSFORMER

CURRENT

BLOCKS

TERMINAL

BREAKERS

CIRCUIT

DEVICES

RELAYS AND

AUXILIARY

BOTTOM PANEL

CONTROL CABINET LAYOUT

DEVICES

ASSOCIATED

TTM AND

QTMS

TRANSFORMER MONITORING SYSTEM

TEST

MENU

RESET

ENTER

B

A

C D E

F

G

HEATERHEATER

(FRONT VIEW)

LEFT SWING PANEL

LH SIDE PANEL

CABINET LIGHT

WIRING TO POWER CABINET

BUSHING FOR 120 VAC

WIREWAY HOLE WITH

5453 55 56

6352 64

59 62

(NOTE 2)

OUTLET

TRANSFORMER MOUNTED CONDUIT

AREA FOR INSTALLATION OF

INSTALLATION TO POWER PLANT

PLATE FOR CONDUIT

AND GASKETED BOTTOM

REMOVABLE BOLTED

CONTROL CABINET TOP VIEW

A F

B EC

G

D

BILL OF MATERIALS - CONTROL CABINET COMPONENTS

58 57

65 67

L A

Y O

U T

HUMIDISTAT / THERMOSTAT (DEVICE 23-1) HAMMOND MFG SKTH012009-C

59 62

59 62

STATES TYPE NT, CLASS 250

STATES TYPE NT, CLASS 251-G

SQUARE D

SQUARE D 8501, TYPE X

59 62

THE REMOVABLE BOTTOM PLATE THICKNESS SHALL BE 10 GAUGE, MINIMUM.6.

CABINET.

THE GFCI OUTLET SHALL BE ACCESSIBLE ONLY FROM INSIDE THE CONTROL5.

IN THE CONTROL CABINET DOOR.

THE FRONT IS VISIBLE THROUGH A WATERPROOF CONTROL VIEWING GLASS

THE RACK CHASSIS AND REMOTELY MOUNTED ON A SWING PANEL SO THAT

CHASSIS IN THE CONTROL CABINET, WITH HMI MODULES MOUNTED AT BOTH

THE TEMPERATURE MONITOR SHALL BE INSTALLED IN A REAR MOUNT4.

ONLY. THE ACTUAL LAYOUT MAY BE MODIFIED BY THE CONTRACTOR.

THE CONTROL CABINET LAYOUT AS SHOWN IS FOR ILLUSTRATIVE PURPOSES3.

ACCORDANCE WITH US STANDARD 508A.

THE TRANSFORMER CONTROL CABINET IS TO BE DESINGED AND BUILT IN2.

INDICATED.

230 KV TRANSFORMER DESIGNS, UNLESS OTHERWISE SPECIFICALLY

ALL ASPECTS OF THIS DRAWING ARE APPLICABLE TO BOTH THE 115 KV AND1.

F R

F .0

E -1

.d g n

F R

F -5 .0

-6 -9

A /2

W F -1

-R -0

R

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

D R

A W

IN

G N

O

F

IL

E N

A M

E

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

R

T L

A N

D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IT

C H

Y A

R D

M

IS

S O

U R I

R

IV

E R

F O

R T R

A N

D A

L L D

A M A

N D R

S

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

W E

R T

R A

N S

F O

R M

E R S

U P

P L

Y

BOTTOM PANEL

POWER CABINET LAYOUT

POWER CABINET - TOP VIEW

D

A C

B

D

AND FAN CONTROL)

LIGHTS, HEATER

(WIRING FOR

BLOCKS

TERMINAL

120 VAC

TRANSFORMER

POWER

AUXILIARY

52 71

CONTACTORS

FAN MOTOR

BREAKERS AND

CIRCUIT

BLOCKS

TERMINAL

BLOCKS

TERMINAL

LH SIDE PANEL RH SIDE PANELBACK PANELA B C

HEATER

CABINET LIGHT

INSTALLATION TO POWER PLANT

PLATE FOR CONDUIT

GASKETED BOTTOM

REMOVABLE BOLTED AND

TRANSFORMER MOUNTED CONDUIT

AREA FOR INSTALLATION OF

CABINET

WIRING TO CONTROL

BUSHING FOR 120 VAC

WIREWAY HOLE WITH

NOTES:

DESCRIPTION BRAND NAME OR EQUAL MODEL NUMBER

MAGNETIC CONTACTORS

MOLDED-CASE CIRCUIT BREAKERS

TERMINAL BLOCKS - CONTROL SIGNAL TYPE

TERMINAL BLOCKS - POWER DISTRIBUTION TYPE

FUSES

FUSE HOLDERS

CABINET HEATER

MARATHON SERIES 142

BUSSMAN

BUSSMAN

WAUKESHA PTC2

KHL

LPJ

JTN600(XX)

QTYITEM

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

AS REQ'D

1 GROUND BUS BAR - -

AUXILIARY POWER TRANSFORMER - -

BILL OF MATERIALS - POWER CABINET COMPONENTS

V

A C P

O W

E R C

A B

IN

E T

E-107

A N

S I

D

D F

IL

E R

D F

IL

E R

B

B O

U W

M A

N

L A

Y O

U T

HUMIDISTAT / THERMOSTAT (DEVICE 23-2) HAMMOND MFG SKTH012009-C

SQUARE D

STATES TYPE NT, CLASS 250

59 62

59 62

59 62

SQUARE D

THE REMOVABLE BOTTOM PLATE THICKNESS SHALL BE 10 GAUGE, MINIMUM.5.

CABINET.

AND POWER TERMINAL BLOCKS SHALL BE MOUNTED IN THE 480 VAC POWER

FANS, INCLUDING THE MOLDED-CASE CIRCUIT BREAKERS, CONTACTORS

ALL 480 VAC PROTECTIVE AND CONTROL EQUIPMENT FOR THE COOLING4.

MAY BE MODIFIED BY THE CONTRACTOR.

THE LAYOUT SHOWN IS FOR ILLUSTRATIVE PURPOSES ONLY. THE LAYOUT3.

ACCORDANCW WITH UL STANDARD 508A.

THE TRANSFORMER POWER CABINET IS TO BE DESIGNED AND BUILT IN2.

INDICATED.

230 KV TRANSFORMER DESIGNS, UNLESS OTHERWISE SPECIFICALLY

ALL ASPECTS OF THIS DRAWING ARE APPLICABLE TO BOTH THE 115 KV AND1.

F R

F -5 .0

-6 -9

A /3

F R

F .0

E -1

.d g n

W F -1

-R -0

R

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

D R

A W

IN

G N

O

F

IL

E N

A M

E

C H

E C

K E

D B

Y

®of Engineers

US Army Corps ®of Engineers

US Army Corps

D R

A W

IN

G N

O

F

IL

E N

A M

R

T L

A N

D

O R

E G

O N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IT

C H

Y A

R D

M

IS

S O

U R I

R

IV

E R

F O

R T R

A N

D A

L L D

A M A

N D R

S

E V

E N R

M

IL

E S P .E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

P O

W E

R T

R A

N S

F O

R M

E R S

U P

P L

Y

L A

Y O

U T A

N D D

E T

A

IL

S

T R

A N

S F

O R

M E

R M

O U

N T

E D D

E V

IC

E S

A N

S I

D

D F

IL

E R

D F

IL

E R

B

B O

U W

M A

N

E-108

(110 C)

SW. #2

(UNUSED)

SW. #1

(125 C)

SW. #3

(LOW LEVEL)

SW. #1

(UNUSED)

SW. #2

(UNUSED)

SW. #1

BULB

HEATER

WELL

BULB

HEATER

WELL

TB5:1 TB5:2 TB5:3 TB5:4 TB5:5 TB5:6

OUTPUT RELAY

GAS ALARM

T X

T X

R X

R X

S G

N D

LEGEND:

NOTES:

(BELOW)

DIAGRAM

SEE CT

(DEVICE 49Q1)

THERMOWELL

HEATED

TOP OIL THERMOWELLS

(DEVICE 49Q2)

WITH NPT PLUG

THERMOWELL

SPARE HEATED

(DEVICE 26Q1)

THERMOWELL

(DEVICE 26Q2)

THERMOWELL

(WITH NPT PLUG)

THERMOWELL

SPARE

(DEVICE 49WTI)

WINDING TEMPERATURE INDICATOR

(DEVICE 26Q)

OIL TEMPERATURE INDICATOR

BOTTOM OIL THERMOWELL

MODULE

INPUT

ANALOG

TTM

(DEVICE 30)

ANNUNCIATION

(DEVICE 94X)

TRANS. TRIP

(DEVICE 95Q)

GAS-IN-OIL MONITOR

(DEVICE 30)

ANNUNCIATION

(DEVICE 30)

ANNUNCIATION

(DEVICE 94X)

TRANSFORMER TRIP

SENSOR #1

PRESSURE

SENSOR #2

PRESSURE

SENSOR #3

PRESSURE

(DEVICE 63PM)

ELECTRONIC PRESSURE MONITOR

RISE

FAST PRESSURE

RISE

SLOW PRESSURE

(DEVICE 30)

ANNUNCIATION

TO TTM (TB2)

COMMUNICATIONS

RS-485

(49WTI)

HEATER

THERMOWELL

(SPARE)

HEATER

THERMOWELL

(SEE NOTE 2)

ANALOG INPUT MODULE

TTM

HEATED THERMOWELLS

CURRENT TRANSFORMERS AND

WINDINGS ASSEMBLY

TRANSFORMER CORE AND

(TYPICAL)

SEE NOTE 3

BCT-H1

BCT-H4

BCT-H2

BCT-H5

BCT-H3

BCT-H6

BCT-H0 CT-X2 49R

49Q1

49Q2

(BELOW)

DIAGRAM

SEE CT

H1 H2 H3

H0 X1 X2 X3

H1

H0

H3

H2

X1

X3

X2

INPUT 4

INPUT 1

RTD1

2 31

95Q-CT

TTM-CT

TERMINALS

LOADGUIDE

TERMINATED ON SHORTING TERMINAL BLOCKS.

SECONDARY WIRING IS TO BE ROUTED TO THE CONTROL CABINET AND

ALL BUSHING CURRENT TRANSFORMERS AND CURRENT TRANSFORMER3.

CONNECTION DETAILS.

SEE DRAWING E-603 FOR TRANSFORMER TEMPERATURE MONITOR2.

INDICATED.

230 KV TRANSFORMER DESIGNS, UNLESS OTHERWISE SPECIFICALLY

ALL ASPECTS OF THIS DRAWING ARE APPLICABLE TO BOTH THE 115 KV AND1.

(DEVICE 63PR)

PRESSURE RELIEF DEVICE

(DEVICE 30)

ANNUNCIATION

(ALARM)

SW. #1

(DEVICE 94X)

TRANS. TRIP

(TRIP)

SW. #2

(DEVICE 71Q)

OIL LEVEL INDICATOR

(CRITICAL-LOW LEVEL)

SW. #2

TS

(DEVICE 30)

ANNUNCIATION

(ALARM)

SW. #1

(TRIP)

SW. #2

(DEVICE 63GDR)

GAS DETECTOR RELAY

LOW VOLTAGE BUSHINGSX1,2,3

TRANSFORMER TEMPERATURE MONITORTTM

TEST SWITCHTS

TERMINAL BLOCKTB_

SWITCHSW

RESISTANCE TEMPERATURE DETECTORRTD

HIGH VOLTAGE BUSHINGSH1,2,3

HIGH VOLTAGE NEUTRAL BUSHINGH0

FAN CURRENT TRANSFORMERFCT

CURRENT TRANSFORMERCT

MULTI-RATIO BUSHING CURRENT TRANSFORMERBCT

GAS-IN-OIL MONITOR95Q

TRIP AUXILIARY RELAY94X

TRANSFORMER LOCKOUT RELAY86T

OIL LEVEL INDICATOR71Q

ELECTRONIC PRESSURE MONITOR63PM

PRESSURE RELIEF DEVICE63PR

GAS DETECTOR RELAY63GDR

ANALOG WINDING TEMPERATURE INDICATOR49WTI

CALIBRATION RESISTOR49R

HEATED THERMOWELLS49Q1,2

ANNUNCIATOR30

THERMOWELL26Q1,2,3

ANALOG OIL TEMPERATURE INDICATOR26Q

AMBIENT AIR TEMPERATURE26A

(NOT USED)

CABINET

WIRED TO

(NOT USED)

CABINET

WIRED TO

(NOT USED)

CABINET

WIRED TO

(NOT USED)

CABINET

WIRED TO

(NOT USED)

CABINET

WIRED TO

F R

F .0

E -1

.d g n

F R

F -5 .0

-6 -9

A /4

(DEVI…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.