FCBA__ADVERTISEMENT_-_HALF_SIZE.pdf
PDF 43 MB Posted
- Attached to
- Automated Infantry Platoon Battle Course (IPBC) for Ft. Carson, CO Federal contract opportunity
- Solicitation number
- W9128F17R0078
About this file
Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Am-0006_W9128F-17-R-0078.pdf | ||
| Am-0004_W9128F-17-R-0078.pdf | ||
| Am-0004-DRAWINGS.pdf | ||
| FCBAC-SP2D01.dgn | — | |
| FCBAC-GP0001.dgn | — | |
| FCBAV-SP0002.dgn | — | |
| FCBAV-SP0002.dgn | — | |
| Am-0003-W9128F-17-R-0078.pdf | ||
| FCBAC-GP0001.dgn | — | |
| FCBAC-SP0001.dgn | — | |
| FCBAC-GP2D01.dgn | — | |
| FCBAC-SP0001.dgn | — | |
| FCBAC-SP2D01.dgn | — | |
| Am-0003-DRAWINGS.pdf | ||
| FCBAC-GP2D01.dgn | — | |
| Am-0002_W9128F-17-R-0078.pdf | ||
| Am-0002-DRAWINGS.pdf | ||
| Am-0001_W9128F-17-R-0078.pdf | ||
| FCBA__ADVERTISEMENT.PDF | ||
| RTA-SPECS_W9128F-17-R-0078_AIPBC_Fort-Carson.pdf |
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S-301
S-301
HSS 4x4x1/4 HSS 4x 4x
1/4
S-301
12' - 4"
0' - 8" 0' - 8"
0'
8"
0'
8"
4'
4" 2'
2'
S-301
S-301
S-301
S-301
S-301
4' - 0"
EL: 97' - 0"
T.O.F.
EL: 97' - 0"
T.O.F.
TOP OF PIER BR.
100' - 4"EL:
97' - 0" T.O.F.
(2) #4 BARS SEE
6/S-003
SLAB ON GRADE
SEE NOTES THIS
SHEET
S-504
LI
G
H
TG
AG
E
ST
EE
L
TR
U
SS
ES
'-0
" O .C
12' - 0"
R
ID
G E
600S250-097 @ 4'-0" O.C.
W8X18
W 8X
W 8X
S-504
S-504
S-504
S-504
5' - 6" 5' - 6"0' - 6" 0' - 6"
9'
6"
S-009
TYP. AT
CORNERS
S-504
TO
S.
E L:
'-1 1"
TO
S.
E L:
'-1 1"
TOS. EL: 110'-11"
S-504
S-504
S-504
BETWEEN
TRUSSES
AT
TRUSS
BRG.
BETWEEN
TRUSSES
AT
TRUSS
BRG.
TRUSS BRG.
EL: 110'-11"
2'
0" 0'
6"
2'
0"
S-009 TYP.
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
S-101AB
AM
M
O B
R
EA
KD
O
W N
B U
IL
D
IN
G
F O U
N D
AT
IO
N A
N D
R O
O F
FR
A M
IN
G
P
LA
N
AU
TO
M
AT
ED
I N
FA
N
TR
Y
PL
AT
O O
N B
A T
TL
E C
O U
R
SE
FO
R
T C
AR
SO
N , C
O
LO
R
AD
O
PN
7 2
(F
Y 1 7)
O M
A H A
D
IS
T R
IC
T O
M
AH
A N
EB
R
AS
KA
D . F
R
EN
C H
D . F
R
EN
C H
W . B
O
EC
K
K.
C
H
AN
/2
7/
W
F-
-R
-0
F1
-9 7-
S- 1 0
1A B-
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
1/2" = 1'-0"S-101AB
1 AMMO BREAKDOWN FOUNDATION
1/2" = 1'-0"S-101AB
2 AMMO BREAKDOWN ROOF FRAMING
GENERAL FOUNDATION NOTES: FOUNDATION LEGEND: GENERAL FRAMING NOTES: FRAMING LEGEND:
1. REFER TO SHEETS S-001 THROUGH S-010 FOR GENERAL NOTES, TYPICAL
SCHEDULES AND TYPICAL DETAILS.
2. TOP OF SLAB-ON GRADE REFERENCE ELEVATION EQUALS 100'-0" UNLESS
NOTED OTHERWISE. SEE CIVIL DRAWINGS FOR MSL DATUM.
3. ALL SLABS-ON-GRADE SHALL BE 6" THICK REINFORCED WITH #4 @ 18" O.C.
E.W., U.N.O.
4. TOP OF FOOTING REFERENCE SHALL BE 97'-0" U.N.O.
5. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL DIMENSIONS.
6. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR EQUIPMENT
PADS AND WALL PENETRATIONS.
1. REFER TO SHEETS S-001 THROUGH S-010 FOR GENERAL NOTES,
TYPICAL CONNECTIONS SCHEDULES AND TYPICAL DETAILS.
2. REFER TO ARCHITECTURAL DRAWINGS FOR ADDTIONAL
DIMENSIONS.
3. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR
EQUIPMENTS INFORMATION.
4. REFER TO DETAIL 5 ON SHEET S-008 FOR LIGHT GAUGE TRUSS
LOAD DIAGRAM.
5. TRUSS MANUFACTURER SHALL BE RESPONSIBLE FOR ALL TEMPORARY
AND PERMANENT REQUIRED BRACING.
8" PRECAST CONCRETE WALL 8" PRECAST CONCRETE WALL
1½" DEEP, 18 GAGE WIDE-RIB ROOF
DECK, GALVANIZED (SEE SHEET S-009)
PLAN NORTH
2' 4'1'0
SCALE: 1/2" = 1'-0"
A-300AB
A-300AB
A-200AB
A-200AB
A-200AB
A-200AB
TUBE STEEL COLUMNS, SEE STRUCTURAL
COILING COUNTER
DOOR
CONCRETE SLAB
COUNTER
ROOF ABOVE
100A
B
3' - 0" 6' - 0" 3' - 0"
AMMO
BREAKDOWN
X WALL TYPE SEE SHEETS A-410
SYMBOLS LEGEND
X WINDOW TYPE SEE SHEETS A-600
X MATERIAL COLOR/FINISH LOCATION SEE
SHEETS A-200XX
LOUVER SEE - A-600LX CJ GWB CONTROL JOINT IN INTERIOR WALLS
FEC FIRE EXTINGUISHER CABINET SEE DETAILS A-581
SNOW GUARDS
PERIMETER OF
BUILDING BELOW
RIDGE CAP
/4
2' - 0"
A-520
MTL. RAIN DIVERTER
ABOVE. PERSONNEL DOOR
BELOW SNOW GUARD
-LENGTH SHALL MATCH
SNOW GUARD
2' - 0"
4" / 1'-0"4" / 1'-0"
GENERAL ROOF NOTES:
1. ALL DIMENSIONS ARE NOMINAL, UNLESS NOTED OTHERWISE.
2. SEE ELECTRICAL DRAWINGS FOR LOCATIONS OF LIGHTNING PROTECTIONS
TERMINALS.
3. DO NOT SCALE FROM DRAWINGS.
4. REFER TO CIVIL SITE PLAN FOR BUILDING LOCATION.
5. COORDINATE ALL ROOF PENETRATIONS WITH STANDING SEAM LOCATIONS.
6. ALL ROOFING, FLASHING, & ACCESSORIES TO BE INSTALLED IN ACCORDANCE WITH
SMACNA GUIDELINES.
7. ALL FINISHES TO BE FACTORY PRE-FINISHED.
8. ALL JOINTS, OPENINGS, & PENETRATIONS TO RECEIVE TAPE/FLASHING, CAULK,
GASKETS SEALANTS, AND/OR WEATHER STRIPPING AS REQUIRED.
9. ALL PENETRATIONS THROUGH ROOF SHALL BE INTEGRATED INTO THE CONTINUOUS
AIR BARRIER SYSTEM.
10. REFER TO STRUCTURAL DRAWINGS FOR FRAMING INFORMATION.
PRE-FINISHED METAL
SOFFIT PANELS
OUTLINE OF ROOF
9' - 8"
9' - 5"
2X2 CEILING GRID
GWB CEILING
2X4 LIGHTING FIXTURE
AFFX'-X" CEILING HEIGHT
(ABOVE FINISH FLOOR)
CEILING LEGEND:
PENDANT FIXTURE
MTL. SOFFIT PANEL
ELECTRIC A/C
EXHAUST GRILL
RECESSED FIXTURE
REFLECTED CEILING PLAN NOTES:
1. DO NOT SCALE FROM DRAWINGS.
2. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL LIGHTING INFORMATION
3. REFER TO MECHANICAL DRAWINGS FOR DUCT & DIFFUSER INFORMATION
GENERAL NOTES:
1. ROOM FINISH SCHEDULES MAY BE FOUND ON A-600 SHEET.
2. DOOR SCHEDULES MAY BE FOUND ON A-600 SHEET.
3. WINDOW SCHEDULES MAY BE FOUND ON A-600 SHEETS.
4. DO NOT SCALE FROM DRAWINGS.
5. SEE CIVIL SITE PLAN FOR BUILDING LOCATION
6. CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ALL WINDOW, DOOR, LOUVER,
AND OTHER OPENINGS PRIOR TO MANUFACTURING OR INSTALLING ANY SUCH ITEM.
ALL OPENINGS SIZES ARE NOMINAL. CONTRACTOR SHALL VERIFY THE ACTUAL SIZE
REQUIRED FOR EACH OPENING.
7. DIMENSIONS ARE TO CENTER LINE OF COLUMNS, FACE OF STEEL STUDS AND FACE OF
PRECAST WALLS.
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
A-101AB
A M
M O
B R
E A
K D
O W
N F
L O
O R
C
E
IL
IN
G
R O
O F
P L A
N
A U
T O
M A
T E
D I N
F A
N T
R Y
P L A
T O
O N
B A
T T
L E
C O
U R
S E
O M
A H
A D
IS
T
R
IC
T O
M A
H A
N
E B
R A
S K
A
A M
P
A M
P
B R
G
B R
G
/2
/2
W F
-1 -R
-0
F -9
-0
F O
R T
C A
R S
O N
C
O L O
R A
D O
P N
F
Y
1/4" = 1'-0"A-101AB
1 FLOOR PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
PLAN NORTH
1/4" = 1'-0"A-101AB
2 ROOF PLAN
1/4" = 1'-0"A-101AB
3 CEILING PLAN
4' 8'0 2'
GENERAL ELEVATION NOTES:
1. SEE A-101XX FOR STRUCTURAL GRID DIMENSIONS.
2. SEE A-600 FOR WINDOW TYPES, LOUVER TYPES AND
DOOR NUMBERS NOT SHOWN ON THE ELEVATIONS.
3. SEE ROOF PLANS FOR SIZES AND LOCATIONS OF
OTHER ROOF ELEMENTS.
B.O. SOFFIT - AB
109' - 6"
F.F. - AB
100' - 0"
TUBE STEEL COLUMN
PRECAST CONCRETE PANEL
COILING COUNTER DOOR
MTL. WALL PANEL
SNOW GUARDS
MTL. FASCIA
MTL. ROOF PANEL
STRUCTURAL STOOP (SEE STRUCT.)
DOOR HEAD - AB
107' - 4"
T.O. RIDGE - AB
113' - 5"
3 3
B.O. SOFFIT - AB
109' - 6"
F.F. - AB
100' - 0"
SNOW GUARDS
MTL. FASCIA
MTL. ROOF PANEL
T.O. RIDGE - AB
113' - 5"
B.O. SOFFIT - AB
109' - 6"
F.F. - AB
100' - 0"
PRECAST CONCRETE PANEL
MTL. FASCIA
MTL. ROOF PANEL
TUBE STEEL COLUMN
T.O. RIDGE - AB
113' - 5"
B.O. SOFFIT - AB
109' - 6"
F.F. - AB
100' - 0"
PRECAST CONCRETE PANEL
MTL. FASCIA
MTL. ROOF PANEL
HM DOOR & FRAME
SNOW GUARDS
DR HEAD - AB
107' - 2"
T.O. RIDGE - AB
113' - 5" 3
RED & WHITE LIGHT (TYP.)
1 SMOOTH FACE FAMILIAR BEIGE SHERWIN WILLIAMS SW6093
2 SPLIT FACE 8" x 16" FAMILIAR BEIGE GENERAL SHALE
3 SSMR/SOFFIT/FASCIA COLONIAL RED MBCI
4 METAL PANEL/LOUVERS BROWNSTONE MBCI
5 METAL TRIM (DOORS/FRAMES) FOOTHILLS SHERWIN WILLIAMS SW7514
6 ALUM WINDOWS CLEAR ANODIZED AA-M12C22A41
7 STRUCTURAL STEEL FOOTHILLS SHERWIN WILLIAMS SW7514
MARK: FINISH: PATTERN: COLOR: NOMENCLATURE:
COLOR FINISH LEGEND
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
A-200AB
B U
IL
D
IN
G
E L E
V A
T
IO
N S
A U
T O
M A
T E
D I N
F A
N T
R Y
P L A
T O
O N
B A
T T
L E
C O
U R
S E
O M
A H
A D
IS
T
R
IC
T O
M A
H A
N
E B
R A
S K
A
A M
P
A M
P
B R
G
B R
G
/2
/2
W F
-1 -R
-0
F -9
-0
F O
R T
C A
R S
O N
C
O L O
R A
D O
P N
F
Y
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
1/4" = 1'-0"A-200AB
1 NORTH ELEVATION
1/4" = 1'-0"A-200AB
2 SOUTH ELEVATION
1/4" = 1'-0"A-200AB
3 EAST ELEVATION
1/4" = 1'-0"A-200AB
4 WEST ELEVATION
T ectonic Cop yright 2007
F.F. - AB
100' - 0"
COILING COUNTER DOOR
SST
COUNTER
COUNTER
SUPPORTS
GWB CEILING
SSMR ROOF
PRECAST CONCRETE
PANEL
PAINTED PRECAST
CONCRETE PANEL
4" RESILIENT BASE
BACKSPLASH
PRE-FINISHED METAL
SOFFIT
A-400AB
A-400AB
B.O. SOFFIT- AB
109' - 5"
DOOR HEAD - AB
107' - 4"
METAL FRAMING (TYP.)
SSMR ROOF
SNOW GUARDS
PRECAST CONCRETE
PANELS
HM DOOR AND FRAME
PAINTED PRECAST
CONCRETE PANEL
4" RESILIENT BASE
A-400AB
F.F. - AB
100' - 0"
T.O. COUNTER
103' - 4"
SST COUNTER
B.O. SOFFIT- AB
109' - 5"
STRUCTURAL STOOP
DR HEAD - AB
107' - 2"
GENERAL SECTION NOTES:
1. DO NOT SCALE FROM DRAWINGS.
2. SEE CIVIL SITE PLAN FOR BUILDING LOCATION
3. CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ALL WINDOW,
DOOR, LOUVER, AND OTHER OPENINGS PRIOR TO MANUFACTURING
OR INSTALLING ANY SUCH ITEM.
4. ALL OPENINGS SIZES ARE NOMINAL. CONTRACTOR SHALL
VERIFY THE ACTUAL SIZE REQUIRED FOR EACH OPENING.
5. ALL JOINTS & PENETRATIONS TO RECEIVE FLASHING, CAULK, GASKETS,
SEALANTS, OR WEATHERSTRIPPING AS REQUIRED.
6. SEE STRUCTURAL DRAWINGS FOR BEARING HEIGHTS & FRAMING
INFORMATION.
7. ALL FASTENERS TO BE SELECTED FOR DURABILITY IN LOCAL CLIMATE.
8. SEE STRUCTURAL DRAWINGS FOR CONCRETE FLOOR SLAB AND
FOUNDATION INFORMATION.
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
A-300AB
B U
IL
D
IN
G
S E
C T
IO
N
S
A U
T O
M A
T E
D I N
F A
N T
R Y
P L A
T O
O N
B A
T T
L E
C O
U R
S E
O M
A H
A D
IS
T
R
IC
T O
M A
H A
N
E B
R A
S K
A
A M
P
A M
P
B R
G
B R
G
/2
/2
W F
-1 -R
-0
F -9
-0
F O
R T
C A
R S
O N
C
O L O
R A
D O
P N
F
Y
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
1/4" = 1'-0"A-300AB
1 BUILDING SECTION
1/4" = 1'-0"A-300AB
2 BUILDING SECTION
F.F. - AB
100' - 0"
CONCRETE SLAB
RESILIENT BASE
COILING COUNTER DOOR
SSMR
METAL DECKING
TRUSS
PRE-FINISHED METAL SOFFIT
CEILING AS INDICATED PER ROOM
FINISH SCHEDULE
COUNTER W/BACKSPLASH
FOOTING AND FOUNDATION
-SEE STRUCTURAL
A-501
F.F. - AB
100' - 0"
A-520
CONCRETE SLAB
RESILIENT BASE
SSMR
METAL DECKING
METAL FRAMING
TRUSS
B.O. SOFFIT - AB
109' - 6"
CONCRETE SLAB
RESILIENT BASE
DOOR FRAME
SSMR
METAL DECKING
METAL FRAMING
TRUSS
PRE-FINISHED METAL SOFFIT
PRE-FINISHED METAL FASCIA
CEILING AS INDICATED PER ROOM
FINISH SCHEDULE
COUNTER W/BACKSPLASH
FOOTING AND FOUNDATION
-SEE STRUCTURAL
A-520
DR HEAD - AB
107' - 2"
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
A-400AB
W A
L L S
E C
T
IO
N S
A U
T O
M A
T E
D I N
F A
N T
R Y
P L A
T O
O N
B A
T T
L E
C O
U R
S E
O M
A H
A D
IS
T
R
IC
T O
M A
H A
N
E B
R A
S K
A
A M
P
A M
P
B R
G
B R
G
/2
/2
W F
-1 -R
-0
F -9
-0
F O
R T
C A
R S
O N
C
O L O
R A
D O
P N
F
Y
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
1" = 1'-0"A-400AB
1 WALL SECTION
1" = 1'-0"A-400AB
2 WALL SECTION
1" = 1'-0"A-400AB
3 WALL SECTION 0 1' 2'
G
Panel AB
AB-1
AMMO
BREAKDOWN
AMMO
BREAKDOWN
AB-2
AB-3
A
B
B
B
BA
A
Panel AB
K
F
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
E-101AB
AM
M
O B
R E A
KD
O
W N
P
LA
N S
AU
TO
M
AT
ED
IN
FA
N
TR
Y
PL
AT
O O
N B
A T
TL
E C
O U
R
SE
O M
A H A
D
IS
T R
IC
T O
M
AH
A, N
EB
R
AS
KA
B.
W
LA
SC
H
IN
B.
W
LA
SC
H
IN
S.
O
TT
S.
O
TT
/2
7/
W
F-
-R
-0
F1
-9 7-
FO
R
T C
AR
SO
N , C
O
LO
R
AD
O
PN
7 2
(F
Y 1 7)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
1/4" = 1'-0"E-101AB
1 AMMO BREAKDOWN POWER PLAN
1/4" = 1'-0"E-101AB
2 AMMO BREAKDOWN LIGHTING PLAN
1/4" = 1'-0"E-101AB
3 AMMO BREAKDOWN GROUNDING PLAN
GENERAL NOTES:
1. ALL UNDERGROUND CONDUCTOR BONDS SHALL BE EXOTHERMICALLY
WELDED.
2. LIGHTNING PROTECTION SYSTEM SHALL BE PROVIDED BY A QUALIFIED
CONTRACTOR.
3. REFER TO SHEETS EL501 AND EL502 FOR LUMINAIRE SCHEDULE AND
LUMINAIRE DETAILS.
4. REFER TO SHEET EP602 FOR PANEL SCHEDULES.
5. PROVIDE STRUCTURAL MOUNTING WITH METAL BRACES THAT RIGIDLY
SUPPORT BOXES/FIXTURES.
6. AS A MINIMUM, ALL MATERIALS AND INSTALLATION WITHIN THE AMMO
BREAKDOWN STRUCTURE SHALL BE IN ACCORDANCE WITH NFPA 70,
CLASS II, DIVISION 2, HAZARDOUS (CLASSIFIED) LOCATION. GROUPS E, F &
G, WITH MAXIMUM SURFACE TEMPERATURE OF T3B.
7. NFPA 780, CLASS I MATERIALS SHALL BE PROVIDED FOR THE LIGHTNING
PROTECTION SYSTEM, UNLESS OTHERWISE NOTED. MAIN CONDUCTOR: #
2/0 AWG MIN.
8. EXPOSE CONDUIT WITH SURFACE MOUNTED DEVICES, OUTLETS, AND
PANELS WHENEVER POSSIBLE.
9. ASSURE EQUIPMENT, DEVICES, BOXES, CONDUIT BODIES, AND
HANDHOLE ENCLOSURES ARE ACCESSIBLE AND/OR READILY ACCESSABLE
AS REQUIRED BY NFPA 70.
10. CONNECT LIGHTNING PROTECTION SYSTEM TO SNOW RETENTION
DEVICES WHERE APPLICABLE.
11. MOUNT RECEPTACLES ABOVE FINISHED COUNTERTOPS.
12. REFER TO SHEET EG501 FOR LIGHTNING PROTECTION AND GROUNDING
DETAILS.
KEYED NOTES:
1. EXOTHERMICALLY WELDED CONNECTION. CONNECTIONS WITHIN
GROUND WELLS MUST BE BOLTED. SEE SHEET EG501. TYPICAL.
2. 3/4" DIAMETER X 12' - 0" COPPER CLAD GROUND ROD AND GROUNDING
WELL. SEE SHEET EG501. TYPICAL.
3. #2/0 AWG COPPER BUILDING PERIMETER COUNTERPOISE CONDUCTOR,
RATED NFPA 780 CLASS II, TYPICAL. BURIAL DEPTH SHALL BE 36", MIN.
4. ASSURE ALL GROUNDING MEDIA IN OR ON THE AMMUNITION
BREAKDOWN STRUCTURE IS INTERCONNECTED WITH THE LIGHTNING
PROTECTION SYSTEM TO PROVIDE COMMON GROUND POTENTIAL. THE
DOWN CONDUCTOR SHALL BE RUN DOWN THE COLUMN IN PVC CONDUIT.
TYPICAL.
5. BOND #1/0 AWG CONDUCTOR TO STRUCTURAL STEEL. SEE SHEET
EG501.
6. BOND #1/0 AWG CONDUCTOR TO WALL REINFORCING STEEL. SEE
SHEET EG501.
7. RED AND WHITE LIGHTING SHALL BE SEPARATELY SWITCHED. LABEL
LIGHT SWITCHES PER USE "RED-INTERIOR", "WHITE-INTERIOR", "RED-
EXTERIOR", "WHITE-EXTERIOR". PROVIDE "WHITE" SWITCH
WEATHERPROOF COVERS WITH A LOCKING TAB. SEE SHEET EL501.
8. 24" NICKEL TIPPED, COPPER CLAD AIR TERMINAL. SEE SHEET EG501
FOR MOUNTING. MAIN LIGHTNING PROTECTION CABLE SIZED #2/0 AWG
MIN. TYPICAL.
9. BOND #1/0 AWG CONDUCTOR TO AMMUNITION BREAKDOWN DOOR
FRAME. SEE SHEET EG501.
5 5
PLAN NORTH
S-302
S-302
HSS 6x 6x
5/1
HSS 6x 6x
5/1
HSS 6x6x5/16
HSS 6x6x5/16 HSS 6x 6x
5/1 6HSS 6x6x5/16
C.C.J.
C .C
.J
C .C
.J
C .C
.J
S-301
F3F2 F2
F1 F1F11 BE
2 BE
A BE B BE C BE
32' - 10"
0' - 11" 0' - 11" 15' - 6" 15' - 6"
0'
4'
0"
S-302
S-302
S-302
S-302
100' - 0"
TOP OF
SLAB
EL:
SL
O
PE
/8
PE
R
F T.
4x4x3/16
CHEVERON BRACES
4x4x3/16
CHEVERON BRACES
(2) #4 BARS SEE
6/S-003
S-2013
TOP OF
SLAB
EL: 97'-0"
SLAB ON GRADE
SEE NOTES THIS
SHEET
10C2.5x097
S-502
1 BE
2 BE
A BE B BE C BE
15' - 6" 15' - 6"
31' - 0"
FR
AM
IN
G
M
EM
BE
R
S 3'
-0 " O
.C . M
AX
10C2.5x097TOS EL = 119'-8"
TOS EL = 116'-0"
END OF BEAM
END OF BEAM
W8X18W8X18
W8X18W8X18
W 8X
18 W 8X
W 8X
S-502
ZS
10x3.25x070
ZS
10x3.25x070
ZS
10x3.25x070
ZS
10x3.25x070
ZS
10x3.25x070
ZS
10x3.25x070
ZS
10x3.25x070
S-502
S-502
4x4x3/16 CHEVRON BRACING
4x4x3/16 KNEE
BRACING
S-2013
Sim
1'
2" 2'
5"
S-502
SIM
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
S-101BE
BL
EA
C H
ER
E
N C
LO
SU
R E
FO
U
N D
AT
IO
N A
N D
R O
O F
F R
AM
IN
G
P
LA
N
AU
TO
M
AT
ED
I N
FA
N
TR
Y
PL
AT
O O
N B
A T
TL
E C
O U
R
SE
FO
R
T C
AR
SO
N , C
O
LO
R
AD
O
PN
7 2
(F
Y 1 7)
O M
A H A
D
IS
T R
IC
T O
M
AH
A N
EB
R
AS
KA
D . F
R
EN
C H
D . F
R
EN
C H
W . B
O
EC
K
K.
C
H
AN
/2
7/
W
F-
-R
-0
F1
-9 7-
S- 1 0
1B E-
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
1/4" = 1'-0"S-101BE
1 BLEACHER ENCLOSURE FOUNDATION
GENERAL FOUNDATION NOTES: FOUNDATION LEGEND: GENERAL FRAMING NOTES: FRAMING LEGEND:
1. REFER TO SHEETS S-001 THROUGH S-010 FOR GENERAL NOTES, TYPICAL
SCHEDULES AND TYPICAL DETAILS.
2. TOP OF SLAB-ON GRADE REFERENCE ELEVATION EQUALS 100'-0" UNLESS
NOTED OTHERWISE. SEE CIVIL DRAWINGS FOR MSL DATUM.
3. ALL SLABS-ON-GRADE SHALL BE 6" THICK REINFORCED WITH #4 @ 18" O.C.
E.W., U.N.O.
4. TOP OF FOOTING REFERENCE SHALL BE 97'-0" U.N.O.
5. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL DIMENSIONS.
6. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR EQUIPMENT
PADS AND WALL PENETRATIONS.
7. DIMENSIONS ARE TO THE FACE OF CONCRETE, U.N.O.
1. REFER TO SHEETS S-001 THROUGH S-010 FOR GENERAL NOTES,
TYPICAL CONNECTIONS SCHEDULES AND TYPICAL DETAILS.
2. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL
DIMENSIONS.
3. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR
EQUIPMENT INFORMATION.
1/4" = 1'-0"S-101BE
2 BLEACHER ENCLOSURE ROOF FRAMING
CONSTRUCTION OR CONTROL JOINT
(SEE DETAILS 1 AND 2 ON SHEET S-003)
MARK FOOTING SIZE FOOTING REINFORCING
BLEACHER ENCLOSURER
SPREAD FOOTING SCHEDULE
F1
F2
F3
3'-0"x3'-0"x1'-0"
4'-0"x4'-0"x1'-0"
5'-0"x5'-0"x1'-0"
(4) #4 EACH WAY TOP MAT
(4) #4 EACH WAY BOTTOM MAT
(4) #4 EACH WAY TOP MAT
(4) #4 EACH WAY BOTTOM MAT
(5) #4 EACH WAY TOP MAT
(5) #4 EACH WAY BOTTOM MAT
1½" DEEP, 18 GAGE WIDE-RIB ROOF
DECK, GALVANIZED (SEE SHEET S-009)
PLAN NORTH
SCALE: 1/4" = 1'-0"
/2
32' - 9"
A-200BE
A-200BE
A-200BE
A-200BE
A-300BE
A-300BE
599 SF
BLEACHER ENCLOSURE
L2
PRE-FINISHED
MTL.
WALL PANEL
WALL GIRT
CONCRETE SLAB
MECHANICAL LOUVER
ABOVE (ABOVE)
GALVANIZED METAL
BLEACHERS, BOLT
TO CONCRETE.
MECHANICAL
LOUVER
(ABOVE)
L2
A BE B BE C BE
1 BE
2 BE
OUTLINE OF
BUILDING
SSMR ROOF
A BE B BE C BE
1 BE
2 BE
GENERAL ROOF NOTES:
1. ALL DIMENSIONS ARE NOMINAL, UNLESS NOTED OTHERWISE.
2. SEE ELECTRICAL DRAWINGS FOR LOCATIONS OF LIGHTNING PROTECTIONS
TERMINALS.
3. DO NOT SCALE FROM DRAWINGS.
4. REFER TO CIVIL SITE PLAN FOR BUILDING LOCATION.
5. COORDINATE ALL ROOF PENETRATIONS WITH STANDING SEAM LOCATIONS.
6. ALL ROOFING, FLASHING, & ACCESSORIES TO BE INSTALLED IN ACCORDANCE WITH
SMACNA GUIDELINES.
7. ALL FINISHES TO BE FACTORY PRE-FINISHED.
8. ALL JOINTS, OPENINGS, & PENETRATIONS TO RECEIVE TAPE/FLASHING, CAULK,
GASKETS SEALANTS, AND/OR WEATHER STRIPPING AS REQUIRED.
9. ALL PENETRATIONS THROUGH ROOF SHALL BE INTEGRATED INTO THE CONTINUOUS
AIR BARRIER SYSTEM.
10. REFER TO STRUCTURAL DRAWINGS FOR FRAMING INFORMATION.
MECHANICAL LOUVER
PRE-FINISHED METAL
WALL PANEL
PRE-FINISHED MTL.
SOFFIT PANEL
A BE B BE C BE
1 BE
2 BE
18' - 8"
15' - 6"
REFLECTED CEILING PLAN NOTES:
1. DO NOT SCALE FROM DRAWINGS.
2. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL LIGHTING INFORMATION
3. REFER TO MECHANICAL DRAWINGS FOR DUCT & DIFFUSER INFORMATION
GWB CEILING
AFFX'-X" CEILING HEIGHT
(ABOVE FINISH FLOOR)
CEILING LEGEND:
PENDANT FIXTURE
MTL. SOFFIT PANEL
PENDANT FIXTURE
SYMBOLS LEGEND
X MATERIAL COLOR/FINISH LOCATION SEE
SHEETS A-200XX
LOUVER SEE - A-600LX
GENERAL NOTES:
1. SEE A-101XX FOR STRUCTURAL GRID DIMENSIONING.
2. ROOM FINISH SCHEDULES MAY BE FOUND ON A-600 SHEET.
3. DOOR SCHEDULES MAY BE FOUND ON A-600 SHEET.
4. WINDOW SCHEDULES MAY BE FOUND ON A-600 SHEETS.
5. DO NOT SCALE FROM DRAWINGS.
6. SEE CIVIL SITE PLAN FOR BUILDING LOCATION
7. CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ALL DOOR & LOUVER OPENINGS
PRIOR TO MANUFACTURING OR INSTALLING ANY SUCH ITEM.
ALL OPENINGS SIZES ARE NOMINAL. CONTRACTOR SHALL VERIFY THE ACTUAL SIZE
REQUIRED FOR EACH OPENING.
8. DIMENSIONS ARE TO CENTER LINE OF COLUMNS, FACE OF STEEL STUDS AND FACE OF
PRECAST WALLS.
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
A-101BE
B L E
A C
H E
R E
N C
L O
S U
R E
F L O
O R
C
E
IL
I N G
R O
O F
P L A
N
A U
T O
M A
T E
D I N
F A
N T
R Y
P L A
T O
O N
B A
T T
L E
C O
U R
S E
O M
A H
A D
IS
T
R
IC
T O
M A
H A
N
E B
R A
S K
A
A M
P
A M
P
B R
G
B R
G
/2
/2
W F
-1 -R
-0
F -9
-0
F O
R T
C A
R S
O N
C
O L O
R A
D O
P N
F
Y
1/4" = 1'-0"A-101BE
1 FLOOR PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
PLAN NORTH
1/4" = 1'-0"A-101BE
2 ROOF PLAN
1/4" = 1'-0"A-101BE
3 REFLECTED CEILING PLAN
SSMR ROOF
LOUVER
PRE-FINISHED METAL
WALL PANEL
F.F. - BE
100' - 0"
A BEB BEC BE
T.O. HEAD - BE
114' - 0"
T.O. DR HEAD - BE
106' - 11"
T.O. ROOF - BE
120' - 10"
PRE-FINISHED MTL.
SOFFIT PANEL
LOUVER
GALVANIZED METAL
BLEACHER BOLTED
IN PLACE.
F.F. - BE
100' - 0"
A BE B BE C BE
4 4
T.O. ROOF - BE
120' - 10"
MTL. WALL PANEL
SSMR ROOF
PRE-FINISHED MTL.
WALL PANEL
PRE-FINISHED MTL.
FASCIA PANEL
F.F. - BE
100' - 0"
1 BE2 BE
12" 2"
T.O. ROOF - BE
120' - 10"
SSMR ROOF
PRE-FINISHED MTL.
WALL PANEL
PRE-FINISHED MTL.
FASCIA PANEL
F.F. - BE
100' - 0"
1 BE 2 BE
12" 2"
T.O. ROOF - BE
120' - 10"
GENERAL ELEVATION NOTES:
1. SEE A-101XX FOR STRUCTURAL GRID DIMENSIONS.
2. SEE A-600 FOR WINDOW TYPES, LOUVER TYPES AND
DOOR NUMBERS NOT SHOWN ON THE ELEVATIONS.
3. SEE ROOF PLANS FOR SIZES AND LOCATIONS OF
OTHER ROOF ELEMENTS.
1 SMOOTH FACE FAMILIAR BEIGE SHERWIN WILLIAMS SW6093
2 SPLIT FACE 8" x 16" FAMILIAR BEIGE GENERAL SHALE
3 SSMR/SOFFIT/FASCIA COLONIAL RED MBCI
4 METAL PANEL/LOUVERS BROWNSTONE MBCI
5 METAL TRIM (DOORS/FRAMES) FOOTHILLS SHERWIN WILLIAMS SW7514
6 ALUM WINDOWS CLEAR ANODIZED AA-M12C22A41
7 STRUCTURAL STEEL FOOTHILLS SHERWIN WILLIAMS SW7514
MARK: FINISH: PATTERN: COLOR: NOMENCLATURE:
COLOR FINISH LEGEND
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
A-200BE
B U
IL
D
IN
G
E L E
V A
T
IO
N S
A U
T O
M A
T E
D I N
F A
N T
R Y
P L A
T O
O N
B A
T T
L E
C O
U R
S E
O M
A H
A D
IS
T
R
IC
T O
M A
H A
N
E B
R A
S K
A
A M
P
A M
P
B R
G
B R
G
/2
/2
W F
-1 -R
-0
F -9
-0
F O
R T
C A
R S
O N
C
O L O
R A
D O
P N
F
Y
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
1/4" = 1'-0"A-200BE
1 NORTH ELEVATION 1/4" = 1'-0"A-200BE
2 SOUTH ELEVATION
1/4" = 1'-0"A-200BE
3 EAST ELEVATION
1/4" = 1'-0"A-200BE
SSMR ROOF OVER
PURLINS OVER METAL
DECK
OUTLINE OF BLEACHERS
PRE-FINISHED MTL.
WALL PANEL
A-400BE
F.F. - BE
100' - 0"
1 BE2 BE
T.O. ROOF - BE
120' - 10"
SSMR ROOF
PRE-FINISHED MTL.
WALL PANEL
PRE-FINISHED MTL.
FASCIA PANEL
GALVANIZED METAL
BLEACHERS BOLTED
IN PLACE
F.F. - BE
100' - 0"
A BE B BE C BE
A-400BE
GENERAL SECTION NOTES:
1. DO NOT SCALE FROM DRAWINGS.
2. SEE CIVIL SITE PLAN FOR BUILDING LOCATION
3. CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ALL WINDOW,
DOOR, LOUVER, AND OTHER OPENINGS PRIOR TO MANUFACTURING
OR INSTALLING ANY SUCH ITEM.
4. ALL OPENINGS SIZES ARE NOMINAL. CONTRACTOR SHALL
VERIFY THE ACTUAL SIZE REQUIRED FOR EACH OPENING.
5. ALL JOINTS & PENETRATIONS TO RECEIVE FLASHING, CAULK, GASKETS,
SEALANTS, OR WEATHERSTRIPPING AS REQUIRED.
6. SEE STRUCTURAL DRAWINGS FOR BEARING HEIGHTS & FRAMING
INFORMATION.
7. ALL FASTENERS TO BE SELECTED FOR DURABILITY IN LOCAL CLIMATE.
8. SEE STRUCTURAL DRAWINGS FOR CONCRETE FLOOR SLAB AND
FOUNDATION INFORMATION.
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
A-300BE
B U
IL
D
IN
G
S E
C T
IO
N
S
A U
T O
M A
T E
D I N
F A
N T
R Y
P L A
T O
O N
B A
T T
L E
C O
U R
S E
O M
A H
A D
IS
T
R
IC
T O
M A
H A
N
E B
R A
S K
A
A M
P
A M
P
B R
G
B R
G
/2
/2
W F
-1 -R
-0
F -9
-0
F O
R T
C A
R S
O N
C
O L O
R A
D O
P N
F
Y
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
1/4" = 1'-0"A-300BE
1 BUILDING SECTION
1/4" = 1'-0"A-300BE
F.F. - BE
1 BE
A-520
CONCRETE SLAB
SSMR
METAL DECKING
METAL FRAMING
PRE-FINISHED METAL SOFFIT
PRE-FINISHED METAL FASCIA
PRE-FINISHED METAL WALL PANEL
FOOTING AND FOUNDATION
-SEE STRUCTURAL
BASE FLASHING
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
A-400BE
W A
L L S
E C
T
IO
N S
A U
T O
M A
T E
D I N
F A
N T
R Y
P L A
T O
O N
B A
T T
L E
C O
U R
S E
O M
A H
A D
IS
T
R
IC
T O
M A
H A
N
E B
R A
S K
A
A M
P
A M
P
B R
G
B R
G
/2
/2
W F
-1 -R
-0
F -9
-0
F O
R T
C A
R S
O N
C
O L O
R A
D O
P N
F
Y
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
3/4" = 1'-0"A-400BE
1 WALL SECTION 0 1' 2' 3'
AB-4
AB-7
D
C
C C
D D D
D D D D
C
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
S
U E
D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
E-101BE
BL
EA
C H
ER
E
N C
LO
S U
R
ES
P
LA
N S
AU
TO
M
AT
ED
IN
FA
N
TR
Y
PL
AT
O O
N B
A T
TL
E C
O U
R
SE
O M
A H A
D
IS
T R
IC
T O
M
AH
A, N
EB
R
AS
KA
B.
W
LA
SC
H
IN
B.
W
LA
SC
H
IN
S.
O
TT
S.
O
TT
/2
7/
W
F-
-R
-0
F1
-9 7-
FO
R
T C
AR
SO
N , C
O
LO
R
AD
O
PN
7 2
(F
Y 1 7)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
1/4" = 1'-0"E-101BE
1 BLEACHER ENCLOSURES POWER PLAN
1/4" = 1'-0"E-101BE
2 BLEACHER ENCLOSURES LIGHTING PLAN
1/4" = 1'-0"E-101BE
3 BLEACHER ENCLOSURE GROUNDING PLAN
GENERAL NOTES:
1. ALL UNDERGROUND CONDUCTOR BONDS SHALL BE
EXOTHERMICALLY WELDED.
2. LIGHTNING PROTECTION SYSTEM SHALL BE PROVIDED BY A
QUALIFIED CONTRACTOR.
3. REFER TO SHEETS EL501 AND EL502 FOR LUMINAIRE SCHEDULE
AND LUMINAIRE DETAILS.
4. REFER TO SHEET EP602 FOR PANEL SCHEDULES.
5. PROVIDE STRUCTURAL MOUNTING WITH METAL BRACES THAT
RIGIDLY SUPPORT BOXES/FIXTURES.
6. NFPA 780, CLASS II MATERIALS SHALL BE PROVIDED FOR THE
LIGHTNING PROTECTION SYSTEM. MAIN CONDUCTOR: #2/0 AWG MIN.
7. EXPOSE CONDUIT WITH SURFACE MOUNTED DEVICES, OUTLETS,
AND PANELS WHENEVER POSSIBLE.
8. ASSURE EQUIPMENT, DEVICES, BOXES, CONDUIT BODIES, AND
HANDHOLE ENCLOSURES ARE ACCESSIBLE AND/OR READILY
ACCESSABLE AS REQUIRED BY NFPA 70.
9. CONNECT LIGHTNING PROTECTION SYSTEM TO SNOW RETENTION
DEVICES WHERE APPLICABLE.
10. REFER TO SHEET EG501 FOR LIGHTNING PROTECTION AND
GROUNDING DETAILS.
KEYED NOTES:
1. EXOTHERMICALLY WELDED CONNECTION. CONNECTIONS WITHIN
GROUND WELLS MUST BE BOLTED. SEE SHEET EG501. TYPICAL.
2. 3/4" DIAMETER X 12' - 0" COPPER CLAD GROUND ROD AND
GROUNDING WELL. SEE SHEET EG501. TYPICAL.
3. #2/0 AWG COPPER BUILDING PERIMETER COUNTERPOISE
CONDUCTOR, TYPICAL. BURIAL DEPTH SHALL BE 36", MIN.
4. ASSURE ALL GROUNDING MEDIA IN OR ON THE BLEACHER
ENCLOSURE STRUCTURE IS INTERCONNECTED WITH THE LIGHTNING
PROTECTION SYSTEM TO PROVIDE COMMON GROUND POTENTIAL.
THE DOWN CONDUCTORS SHALL BE RUN DOWN THE COLUMN IN PVC
CONDUIT. TYPICAL.
5. BOND METAL BLEACHERS TO GROUNDING SYSTEM WITH #6 AWG
BARE COPPER CABLE TO PROVIDE COMMON GROUND POTENTIAL.
6. BOND BLEACHER RISERS TOGETHER WITH #6 AWG BARE COPPER.
7. RED AND WHITE LIGHTING SHALL BE SEPARATELY SWITCHED.
LABEL LIGHT SWITCHES PER USE "RED" AND "WHITE". PROVIDE
"WHITE" SWITCH WEATHERPROOF COVER WITH A LOCKING TAB. SEE
SHEET EL501.
8. 24" NICKEL TIPPED, COPPER CLAD AIR TERMINAL. SEE SHEET
EG501 FOR MOUNTING. MAIN LIGHTNING PROTECTION CABLE SIZED #
2/0 AWG MIN. TYPICAL.
1 CM
2 CM
3 CM
4 CM
A CM B CM
S-502
W 8X
W
8X
W 8X
W
8X
W 8X
W 8X
W10X26
W10X26
W10X26
W10X26
W10X26
W10X26
W10X26
W10X26
2'
6"
9' - 6"
24' - 0"
S-502
2'
6"
9' - 6"
S-502
S-502
S-502
2' - 6" 2' - 6"
ZS
x3 .2
5x
S2
-9
S2
-9
ZS
x3 .2
5x
ZS
x3 .2
5x
ZS
x3 .2
5x
ZS
x3 .2
5x
ZS
x3 .2
5x
ZS
x3 .2
5x
ZS
x3 .2
5x
S-201
T.
O
.S . 1
'-8
T.
O .S
. 1
'-8
T.
O
.S . 1
'-8
T.
O .S
. 1
'-8
S-502
S-502
1 CM
2 CM
3 CM
4 CM
A CM B CM
C.C.J.
C.C.J.
C .C
.J
F1 F1
F1 F1
F1 F1
F1 F1
HSS 7x7x1/2 HSS 7x 7x
1/2
HSS 7x7x1/2
HSS 7x7x1/2
HSS 7x 7x
1/2
HSS 7x7x1/2
HSS 7x 7x
1/2
HSS 7x 7x
1/2
S-301
1'
0" 1'
0"
1' - 0"
21' - 0"
19' - 0" 1' - 0"
S-302
S-301
S-301
S-301
100' - 0"
TOP
OF SLAB.
EL:
100' - 4"
TOP OF PIER
EL:
SLAB ON GRADE
SEE NOTES THIS
SHEET
(2) #4 BARS SEE
6/S-003
S-201
TOP OF PIER
100' - 4"EL:
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
S-101CM
C O
VE
R
ED
M
ES
S
F O U
N D
AT
IO
N A
N D
R O
O F
FR
AM
IN
G
P
LA
N
AU
TO
M
AT
ED
I N
FA
N
TR
Y
PL
AT
O O
N B
A T
TL
E C
O U
R
SE
FO
R
T C
AR
SO
N , C
O
LO
R
AD
O
PN
7 2
(F
Y 1 7)
O M
A H A
D
IS
T R
IC
T O
M
AH
A N
EB
R
AS
KA
D . F
R
EN
C H
D . F
R
EN
C H
W . B
O
EC
K
K.
C
H
AN
/2
7/
W
F-
-R
-0
F1
-9 7-
S- 1 0
1C M
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
1/4" = 1'-0"S-101CM
1 COVERED MESS ROOF FRAMING
1/4" = 1'-0"S-101CM
2 COVERED MESS FOUNDATION
GENERAL FOUNDATION NOTES: FOUNDATION LEGEND: GENERAL FRAMING NOTES: FRAMING LEGEND:
1. REFER TO SHEETS S-001 THROUGH S-010 FOR GENERAL NOTES, TYPICAL
SCHEDULES AND TYPICAL DETAILS.
2. TOP OF SLAB-ON GRADE REFERENCE ELEVATION EQUALS 100'-0" UNLESS
NOTED OTHERWISE. SEE CIVIL DRAWINGS FOR MSL DATUM.
3. ALL SLABS-ON-GRADE SHALL BE 6" THICK REINFORCED WITH #4 @ 18" O.C.
E.W., U.N.O.
4. TOP OF FOOTING REFERENCE SHALL BE 97'-0" U.N.O.
5. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL DIMENSIONS.
6. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR EQUIPMENT
PADS AND WALL PENETRATIONS.
1. REFER TO SHEETS S-001 THROUGH S-010 FOR GENERAL NOTES,
TYPICAL CONNECTIONS SCHEDULES AND TYPICAL DETAILS.
2. REFER TO ARCHITECTURAL DRAWINGS FOR ADDTIONAL
DIMENSIONS.
3. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR
EQUIPMENT INFORMATION.
CONSTRUCTION OR CONTROL JOINT
(SEE DETAILS 1 AND 2 ON SHEET S-003)
MARK FOOTING SIZE FOOTING REINFORCING
COVERED MESS
SPREAD FOOTING SCHEDULE
F1 4'-6"x4'-6"x1'-0"
(5) #4 EACH WAY TOP MAT
(5) #4 EACH WAY BOTTOM MAT
1½" DEEP, 18 GAGE WIDE-RIB ROOF
DECK, GALVANIZED (SEE SHEET S-009)
PLAN NORTH
20' - 0"
COVERED MESS
TUBE STEEL COLUMN (TYP.),
SEE STRUCTURAL
EATING TABLE
2' - 0"
2' - 0"
2' - 0"
CONCRETE SLAB EDGE
ROOF OUTLINE
A-200CM
____________________________________________________A-200CM
A-200CM
B CMA CM
4 CM
3 CM
2 CM
1 CM
A-200CM
SERVING TABLE
SSMR ROOF
B CMA CM
4 CM
3 CM
2 CM
1 CM
/4
2' - 0"
A-520
4" / 1'-0" 4" / 1'-0"
REFLECTED CEILING PLAN NOTES:
1. DO NOT SCALE FROM DRAWINGS.
2. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL LIGHTING INFORMATION
3. REFER TO MECHANICAL DRAWINGS FOR DUCT & DIFFUSER INFORMATION
GENERAL ROOF NOTES:
1. ALL DIMENSIONS ARE NOMINAL, UNLESS NOTED OTHERWISE.
2. SEE ELECTRICAL DRAWINGS FOR LOCATIONS OF LIGHTNING PROTECTIONS
TERMINALS.
3. DO NOT SCALE FROM DRAWINGS.
4. REFER TO CIVIL SITE PLAN FOR BUILDING LOCATION.
5. COORDINATE ALL ROOF PENETRATIONS WITH STANDING SEAM LOCATIONS.
6. ALL ROOFING, FLASHING, & ACCESSORIES TO BE INSTALLED IN ACCORDANCE WITH
SMACNA GUIDELINES.
7. ALL FINISHES TO BE FACTORY PRE-FINISHED.
8. ALL JOINTS, OPENINGS, & PENETRATIONS TO RECEIVE TAPE/FLASHING, CAULK,
GASKETS SEALANTS, AND/OR WEATHER STRIPPING AS REQUIRED.
9. ALL PENETRATIONS THROUGH ROOF SHALL BE INTEGRATED INTO THE CONTINUOUS
AIR BARRIER SYSTEM.
10. REFER TO STRUCTURAL DRAWINGS FOR FRAMING INFORMATION.
B CMA CM
4 CM
3 CM
2 CM
1 CM
11' - 0"8' - 8" 8' - 8"
AFFX'-X" CEILING HEIGHT
(ABOVE FINISH FLOOR)
CEILING LEGEND:
MTL. SOFFIT PANEL
SYMBOLS LEGEND
X MATERIAL COLOR/FINISH LOCATION SEE
SHEETS A-200XX
GENERAL NOTES:
1. SEE A-101XX FOR STRUCTURAL GRID DIMENSIONING.
2. ROOM FINISH SCHEDULES MAY BE FOUND ON A-600 SHEET.
3. DOOR SCHEDULES MAY BE FOUND ON A-600 SHEET.
4. DO NOT SCALE FROM DRAWINGS.
5. SEE CIVIL SITE PLAN FOR BUILDING LOCATION
6. DIMENSIONS ARE TO CENTER LINE OF COLUMNS, FACE OF STEEL STUDS AND FACE OF
PRECAST WALLS.
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
A-101CM
C O
V E
R E
D M
E S
S F
L O
O R
C
E
IL
IN
G
R O
O F
P L A
N
A U
T O
M A
T E
D I N
F A
N T
R Y
P L A
T O
O N
B A
T T
L E
C O
U R
S E
O M
A H
A D
IS
T
R
IC
T O
M A
H A
N
E B
R A
S K
A
A M
P
A M
P
B R
G
B R
G
/2
/2
W F
-1 -R
-0
F -9
-0
F O
R T
C A
R S
O N
C
O L O
R A
D O
P N
F
Y
1/4" = 1'-0"A-101CM
1 FLOOR PLAN
GENERAL ELECTRICAL NOTES:
1. WEATHERPROOF RECEPTACLES @ 10'-0" O.C. (SEE PG 149, DESIGN GUIDE)
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
PLAN NORTH
1/4" = 1'-0"A-101CM
2 ROOF PLAN
1/4" = 1'-0"A-101CM
GENERAL ELEVATION NOTES:
1. SEE A-101XX FOR STRUCTURAL GRID DIMENSIONS.
2. SEE A-600 FOR WINDOW TYPES, LOUVER TYPES AND
DOOR NUMBERS NOT SHOWN ON THE ELEVATIONS.
3. SEE ROOF PLANS FOR SIZES AND LOCATIONS OF
OTHER ROOF ELEMENTS.
F.F - CM
100' - 0"
B.O. SOFFIT - CM
108' - 8"
B CM A CM
MTL. FASCIA
SNOW GUARDS
MTL. ROOF PANEL
MTL. SOFFIT
PREFABRICATED
SS TABLES
CONT. RIDGE
A-200CM
12" 4"
T.O. RIDGE - CM
115' - 3"
F.F - CM
100' - 0"
B.O. SOFFIT - CM
108' - 8"
4 CM 3 CM 2 CM 1 CM
MTL. FASCIA
SNOW GUARDS
MTL. ROOF PANEL
MTL. SOFFIT
TUBE STEEL COLUMN
PREFABRICATED
SS TABLES
CONT. RIDGE
T.O. RIDGE - CM
115' - 3"
F.F - CM
100' - 0"
B.O. SOFFIT - CM
108' - 8"
B CMA CM
MTL. FASCIA
SNOW GUARDS
MTL. ROOF PANEL
MTL. SOFFIT
TUBE STEEL COLUMN
PREFABRICATED
SS TABLES
1 1/2" MTL. DECK
12" 4"
T.O. RIDGE - CM
115' - 3"
F.F - CM
100' - 0"
B.O. SOFFIT - CM
108' - 8"
4 CM 3 CM 2 CM 1 CM
MTL. FASCIA
MTL. ROOF PANEL
MTL. SOFFIT
TUBE STEEL COLUMN
PREFABRICATED
SS TABLES
1 1/2" MTL. DECK
T.O. RIDGE - CM
115' - 3"
EATING TABLE
SERVING TABLE
(1
S
H O
R T
T A
B L E
2' - 0"
/2
1 1/4"
12GA SST - NOTE 9
12 GA SST
STIFFENERS @ 48" OC
(WELD CONTINUOUS
TO POST AND
STIFFENERS)
CONT. WELD
2" DIAM. SST POST
EMBED POST IN
CONCRETE
1 SMOOTH FACE FAMILIAR BEIGE SHERWIN WILLIAMS SW6093
2 SPLIT FACE 8" x 16" FAMILIAR BEIGE GENERAL SHALE
3 SSMR/SOFFIT/FASCIA COLONIAL RED MBCI
4 METAL PANEL/LOUVERS BROWNSTONE MBCI
5 METAL TRIM (DOORS/FRAMES) FOOTHILLS SHERWIN WILLIAMS SW7514
6 ALUM WINDOWS CLEAR ANODIZED AA-M12C22A41
7 STRUCTURAL STEEL FOOTHILLS SHERWIN WILLIAMS SW7514
MARK: FINISH: PATTERN: COLOR: NOMENCLATURE:
COLOR FINISH LEGEND
GENERAL SECTION NOTES:
1. DO NOT SCALE FROM DRAWINGS.
2. SEE CIVIL SITE PLAN FOR BUILDING LOCATION
3. CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ALL WINDOW,
DOOR, LOUVER, AND OTHER OPENINGS PRIOR TO MANUFACTURING
OR INSTALLING ANY SUCH ITEM.
4. ALL OPENINGS SIZES ARE NOMINAL. CONTRACTOR SHALL
VERIFY THE ACTUAL SIZE REQUIRED FOR EACH OPENING.
5. ALL JOINTS & PENETRATIONS TO RECEIVE FLASHING, CAULK, GASKETS,
SEALANTS, OR WEATHERSTRIPPING AS REQUIRED.
6. SEE STRUCTURAL DRAWINGS FOR BEARING HEIGHTS & FRAMING
INFORMATION.
7. ALL FASTENERS TO BE SELECTED FOR DURABILITY IN LOCAL CLIMATE.
8. SEE STRUCTURAL DRAWINGS FOR CONCRETE FLOOR SLAB AND
FOUNDATION INFORMATION.
9. TABLES SHALL BE ROLL-FORMED FROM
CONTINUOUS TYPE 304 STAINLESS STEEL 12GA SHEET METAL.
STIFFENERS AND POST SHALL BE WELDED TO TOP OF COUNTER
PIECE AT FACTORY - GRIND SMOOTH W/ ROUNDED EDGES ALL EXPOSED
CORNERS AND EDGES.
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
A-200CM
B U
IL
D
IN
G
E L E
V A
T
IO
N S
S
E C
T
IO
N S
A U
T O
M A
T E
D I N
F A
N T
R Y
P L A
T O
O N
B A
T T
L E
C O
U R
S E
O M
A H
A D
IS
T
R
IC
T O
M A
H A
N
E B
R A
S K
A
A M
P
A M
P
B R
G
B R
G
/2
/2
W F
-1 -R
-0
F -9
-0
F O
R T
C A
R S
O N
C
O L O
R A
D O
P N
F
Y
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
1/4" = 1'-0"A-200CM
1 NORTH ELEVATION
1/4" = 1'-0"A-200CM
2 EAST ELEVATION
1/4" = 1'-0"A-200CM
5 BUILDING SECTION
1/4" = 1'-0"A-200CM
4 BUILDING SECTION
3/4" = 1'-0"A-200CM
3 TABLE DETAIL
B CMA CM
4 CM
3 CM
2 CM
1 CM
COVERED MESS
AB-6
AB-5
WP
G
WP
G
WP
G
WP
G
WP
G
WP
G
WP
G
WP
G
B CMA CM
4 CM
3 CM
2 CM
1 CM
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
E-101CM
C O
VE
R
ED
M
ES
S
PL
A N
S
AU
TO
M
AT
ED
IN
FA
N
TR
Y
PL
AT
O O
N B
A T
TL
E C
O U
R
SE
O M
A H A
D
IS
T R
IC
T O
M
AH
A, N
EB
R
AS
KA
B.
W
LA
SC
H
IN
B.
W
LA
SC
H
IN
S.
O
TT
S.
O
TT
/2
7/
W
F-
-R
-0
F1
-9 7-
FO
R
T C
AR
SO
N , C
O
LO
R
AD
O
PN
7 2
(F
Y 1 7)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
1/4" = 1'-0"E-101CM
1 COVERED MESS POWER PLAN
1/4" = 1'-0"E-101CM
2 COVERED MESS GROUNDING PLAN
GENERAL NOTES:
1. ALL UNDERGROUND CONDUCTOR BONDS SHALL BE EXOTHERMICALLY
WELDED.
2. LIGHTNING PROTECTION SYSTEM SHALL BE PROVIDED BY A QUALIFIED
CONTRACTOR.
3. REFER TO SHEETS EL501 AND EL502 FOR LUMINAIRE SCHEDULE AND
LUMINAIRE DETAILS.
4. REFER TO SHEET EP602 FOR PANEL SCHEDULES.
5. PROVIDE STRUCTURAL MOUNTING WITH METAL BRACES THAT RIGIDLY
SUPPORT BOXES/FIXTURES.
6. NFPA 780, CLASS I MATERIALS SHALL BE PROVIDED FOR THE LIGHTNING
PROTECTION SYSTEM. MAIN CONDUCTOR: #2/0 AWG MIN.
8. EXPOSE CONDUIT WITH SURFACE MOUNTED DEVICES, OUTLETS, AND
PANELS WHENEVER POSSIBLE.
9. ASSURE EQUIPMENT, DEVICES, BOXES, CONDUIT BODIES, AND
HANDHOLE ENCLOSURES ARE ACCESSIBLE AND/OR READILY
ACCESSABLE AS REQUIRED BY NFPA 70.
10. CONNECT LIGHTNING PROTECTION SYSTEM TO SNOW RETENTION
DEVICES WHERE APPLICABLE.
11. REFER TO SHEET EG501 FOR LIGHTNING PROTECTION AND
GROUNDING DETAILS.
KEYED NOTES:
1. EXOTHERMICALLY WELDED CONNECTION. CONNECTIONS WITHIN
GROUND WELLS MUST BE BOLTED. SEE SHEET EG501. TYPICAL.
2. 3/4" DIAMETER X 12' - 0" COPPER CLAD GROUND ROD AND GROUNDING
WELL. SEE SHEET EG501. TYPICAL.
3. #2/0 AWG COPPER BUILDING PERIMETER COUNTERPOISE CONDUCTOR,
TYPICAL. BURIAL DEPTH SHALL BE 36", MIN.
4. ASSURE ALL GROUNDING MEDIA IN OR ON THE COVERED MESS
STRUCTURE IS INTERCONNECTED WITH THE LIGHTNING PROTECTION
SYSTEM TO PROVIDE COMMON GROUND POTENTIAL. THE DOWN
CONDUCTORS SHALL BE RUN DOWN THE COLUMN IN PVC CONDUIT.
TYPICAL.
5. BOND METAL TABLES AND BENCHES TO GROUNDING SYSTEM WITH #6
AWG BARE COPPER CABLE TO PROVIDE COMMON GROUND POTENTIAL.
TYPICAL
6. BOND DISCONTINUOUS TABLES AND BENCHES TOGETHER WITH #6 AWG
BARE COPPER. TYPICAL.
7. 24" NICKEL TIPPED, COPPER CLAD AIR TERMINAL. SEE SHEET EG501 FOR
MOUNTING. MAIN LIGHTNING PROTECTION CABLE SIZED #2/0 AWG MIN.
TYPICAL.
8. MOUNT RECEPTACLES UNDERNEATH TABLE TOP.
5 6
PLAN NORTH
CT 1
CT 2
CT A CT B
HSS 8x8x1/2
HSS 8x8x1/2
HSS 8x 8x
1/2
HSS 8x8x1/2
TOP OF PIER BR.
TYP.1
S-303
S-303
16' - 0" 4' - 6"
HSS4x4x3/16
CHEVERON BRACES
TYP. (4) SIDES
S-504
U P
M C
X3
M C
X3
100' - 6"
SLAB ON GRADE
SEE NOTES THIS
SHEET
S-2021
LI
G
H
TG
AG
E
TR
U
SS
(4
) E Q
U
AL
S
PA
C
ES
R
ID
G E
LI
N
E
CT 1
CT 2
CT A CT B
4' - 6"
16' - 0"
4' - 6"8' - 0" 8' - 0"
4'
6" 4'
6"
600S250-097 OUTRIGGERS
W
X2
W12X26
W
X2
W12X26
S-501
S-501
S-501
S-501
BETWEEN
TRUSSES
AT
TRUSS BRG.
S-2021
128' - 4 1/2"
128' - 4 1/2"
S-009
TYP.
HSS 4x6x3/16
BRACES SEE
S-203
HSS 4x6x3/16
BRACES SEE
S-203
HSS 4x6x3/16
BRACES SEE
S-203
HSS 4x6x3/16
BRACES SEE
S-203
T.O.S.
T.O.S.
CT 1
CT 2
CT A CT B
W
X2
W
X2
W12X26
W12X26
W10X12
W
X1
W10X12
W
X1
W
X1
W
X1
W12X26
W10X22
W10X22
W10X22
W
X1
W
X1
W
X1
W
X1
W
X1
16' - 0"4' - 1" 4' - 1"
4'
1"
M C
X3
M C
X3
L3X3X1/4
L3 X3X
1/4
M C
X3
M C
X3
U P
D N
S-501
S-501
S-501
HSS 4x4x3/16
BRACES SEE
9/S-501
HSS 4x4x3/16
BRACES SEE
9/S-501
S-501
S-501
S-501
S-504
S-504
HSS4x4x3/16
CHEVERON BRACES
TYP. (4) SIDES
S-202
TOS EL: 108'-10"
TO
S
EL
: 1
'-1
0"
TO
S
EL
: 1
'-1
0"
S-2021
CT 1
CT 2
CT A CT B
W12X26
W
X2
W12X26
W
X2
W10X22
W10X22
W10X22
W
X1
W
X1
W
X1
W
X1
W10X12
W
X1
W12X26
W
X1
W
X1
W
X1
16' - 0"4' - 1"
4'
1"
D N
HSS 4x4x3/16
BRACES SEE
9/S-501 HSS 4x4x3/16
BRACES SEE
9/S-501
S-501
S-501
S-501
S-501
S-501
S-501
S-501
S-2021
S-2032
S-203
TOS EL: 117'-10"
TOS EL: 117'-10"
TO
S
EL
: 1
'-1
0" TO
S
EL
: 1
'-1
0"
Sim. HSS 4x6x3/16
BRACES SEE
S-203
HSS 4x6x3/16
BRACES SEE
S-203
HSS 4x6x3/16
BRACES SEE
S-203
CT DRILLED PIER SCHEDULE
DIAMETER
(INCHES)
PIER LENGTH
(FEET)
VERTICAL
REINFORCING
HORIZONTAL
CLOSED TIES
32 30'-0" (11) #8 #3 @12" O.C.
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
S-101CT
C O
N
TR
O L
TO
W
ER
F
O U
N D
AT
IO
N
O
BS
ER
VA
TI
O
N L
E V
EL
, F
LO
O R
A N
D R
O O
F
FR
AM
IN
G P
LA
N
AU
TO
M
AT
ED
I N
FA
N
TR
Y
PL
AT
O O
N B
A T
TL
E C
O U
R
SE
FO
R
T C
AR
SO
N , C
O
LO
R
AD
O
PN
7 2
(F
Y 1 7)
O M
A H A
D
IS
T R
IC
T O
M
AH
A N
EB
R
AS
KA
D . F
R
EN
C H
D . F
R
EN
C H
W . B
O
EC
K
K.
C
H
AN
/2
7/
W
F-
-R
-0
F1
-9 7-
S- 1 0
1C T-
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
1/4" = 1'-0"S-101CT
1 CONTROL TOWER FOUNDATION
1/4" = 1'-0"S-101CT
2 CONTROL TOWER ROOF FRAMING
1/4" = 1'-0"S-101CT
CONTROL TOWER OBSERVATION LEVEL
FRAMING PLAN
1/4" = 1'-0"S-101CT
4 CONTROL TOWER FLOOR FRAMING PLAN
GENERAL FOUNDATION NOTES:
FOUNDATION LEGEND:
GENERAL FRAMING NOTES:
FRAMING LEGEND:
1. REFER TO SHEETS S-001 THROUGH S-010 FOR GENERAL NOTES, TYPICAL
SCHEDULES AND TYPICAL DETAILS.
2. TOP OF DRILLED PIER REFERENCE ELEVATION EQUALS 100'-6" U.N.O.
3. ALL SLABS-ON-GRADE SHALL BE 4" THICK REINFORCED WITH #4 @ 18" O.C.
E.W., U.N.O.
4. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL DIMENSIONS.
5. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR EQUIPMENT
PADS AND WALL PENETRATIONS.
6. REFER TO SHEET S-202 FOR CONTROL TOWER FRAME ELEVATION.
1. REFER TO SHEETS S-001 THROUGH S-010 FOR GENERAL NOTES,
TYPICAL CONNECTIONS SCHEDULES AND TYPICAL DETAILS.
2. REFER TO ARCHITECTURAL DRAWINGS FOR ADDTIONAL
DIMENSIONS.
3. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR
EQUIPMENT INFORMATION.
4. REFER TO SHEET S-202 AND S-203 FOR CONTROL TOWER
FRAME ELEVATION.
5. REFER TO DETAIL 5 ON SHEET S-008 FOR LIGHT GAUGE
TRUSS LOAD DIAGRAM.
6. TRUSS MANUFACTURER SHALL BE RESPONSIBLE FOR ALL TEMPORARY
AND PERMANENT REQUIRED BRACING.
DRILLED PIER, SEE SCHEDULE ON THIS SHEET.
1½" DEEP, 18 GAGE WIDE-RIB ROOF
DECK, GALVANIZED (SEE SHEET S-009)
4" TOTAL DEPTH CONCRETE SLAB WITH #5
AT 18" O.C. OVER 1.0C20 GALVANIZED FORM
DECK (SEE SHEET S-009). TOP OF SLAB
ELEVATION = 118'-2". DO NOT INVERT DECK.
2" DEEP GALVANIZED BAR GRATE w/ 3/16"
BEARING BARS AT 1 3/16" O.C. & TRANSVERSE
BARS AT 4" O.C. TOP OF GRATING ELEVATION
= 109'-0" AND 118'-2".
PLAN NORTH
289 SF
PAD
CT 1
CT 2
CT A CT B
OBSERVATION
CT 1
CT 2
CT A CT B
252 SF
CONTROL ROOM
/2
17' - 0"
A-200CT
A-200CT
A-200CT
A-200CT
A-300CT
A-300CT
D
D
B B B B
D
D
CT 1
CT 2
CT A CT B
WARNING LIGHT
POLE (TYP.)
WARNING LIGHT
POLE (TYP.)
BUILT-IN COUNTER
15' - 6 3/4"
4' - 2" 11' - 4 3/4"
1' - 1 3/8" 3' - 4" 3' - 4" 3' - 4" 3' - 4" 1' - 1 3/8"
SS WINDOW
STOOL (TYP.)
FEH
GENERAL NOTES:
1. SEE A-101XX FOR STRUCTURAL GRID DIMENSIONING.
2. ALL CHANGES IN FLOOR MATERIALS IN DOOR OPENINGS SHALL OCCUR AT THE CENTER
LINE OF THE DOOR PANEL IN THE CLOSED POSITION UNLESS NOTED OTHERWISE.
3. ROOM FINISH SCHEDULES MAY BE FOUND ON A-600 SHEET.
4. DOOR SCHEDULES MAY BE FOUND ON A-600 SHEET.
5. WINDOW SCHEDULES MAY BE FOUND ON A-600 SHEETS.
6. SEE A-410 FOR WALL TYPE DETAILS
7. DO NOT SCALE FROM DRAWINGS.
8. SEE CIVIL SITE PLAN FOR BUILDING LOCATION
9. CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ALL WINDOW, DOOR, LOUVER, AND
OTHER OPENINGS PRIOR TO MANUFACTURING OR INSTALLING ANY SUCH ITEM.
ALL OPENINGS SIZES ARE NOMINAL. CONTRACTOR SHALL VERIFY THE ACTUAL SIZE
REQUIRED FOR EACH OPENING.
10. DIMENSIONS ARE TO CENTER LINE OF COLUMNS, FACE OF STEEL STUDS AND FACE OF
PRECAST WALLS.
CT 1
CT 2
CT A CT B
A-521
2" / 1'-0" 2" / 1'-0"
GENERAL ROOF NOTES:
1. ALL DIMENSIONS ARE NOMINAL, UNLESS NOTED OTHERWISE.
2. SEE ELECTRICAL DRAWINGS FOR LOCATIONS OF LIGHTNING PROTECTIONS
TERMINALS.
3. DO NOT SCALE FROM DRAWINGS.
4. REFER TO CIVIL SITE PLAN FOR BUILDING LOCATION.
5. COORDINATE ALL ROOF PENETRATIONS WITH STANDING SEAM LOCATIONS.
6. ALL ROOFING, FLASHING, & ACCESSORIES TO BE INSTALLED IN ACCORDANCE WITH
SMACNA GUIDELINES.
7. ALL FINISHES TO BE FACTORY PRE-FINISHED.
8. ALL JOINTS, OPENINGS, & PENETRATIONS TO RECEIVE TAPE/FLASHING, CAULK,
GASKETS SEALANTS, AND/OR WEATHER STRIPPING AS REQUIRED.
9. ALL PENETRATIONS THROUGH ROOF SHALL BE INTEGRATED INTO THE CONTINUOUS
AIR BARRIER SYSTEM.
10. REFER TO STRUCTURAL DRAWINGS FOR FRAMING INFORMATION.
CT 1
CT 2
CT A CT B
252 SF
CONTROL ROOM
27' - 5"
27' - 2"
REFLECTED CEILING PLAN NOTES:
1. DO NOT SCALE FROM DRAWINGS.
2. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL LIGHTING INFORMATION
3. REFER TO MECHANICAL DRAWINGS FOR DUCT & DIFFUSER INFORMATION
GWB CEILING
AFFX'-X" CEILING HEIGHT
(ABOVE FINISH FLOOR)
CEILING LEGEND:
PENDANT FIXTURE
MTL. SOFFIT PANEL
ELECTRIC A/C
EXHAUST GRILL
RECESSED FIXTURE
X WALL TYPE SEE SHEETS A-410
SYMBOLS LEGEND
X WINDOW TYPE SEE SHEETS A-600
X MATERIAL COLOR/FINISH LOCATION SEE
SHEETS A-200XX
CJ GWB CONTROL JOINT IN INTERIOR WALLS
FEC FIRE EXTINGUISHER CABINET SEE DETAILS A-581
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
A-101CT
C O
N T
R O
L T
O W
E R
F L O
O R
C
E
IL
IN
G
R O
O F
P L A
N
A U
T O
M A
T E
D I N
F A
N T
R Y
P L A
T O
O N
B A
T T
L E
C O
U R
S E
O M
A H
A D
IS
T
R
IC
T O
M A
H A
N
E B
R A
S K
A
A M
P
A M
P
B R
G
B R
G
/2
/2
W F
-1 -R
-0
F -9
-0
F O
R T
C A
R S
O N
C
O L O
R A
D O
P N
F
Y
1/4" = 1'-0"A-101CT
1 FLOOR PLAN - FIRST FLOOR
1/4" = 1'-0"A-101CT
3 FLOOR PLAN - SECOND FLOOR
1/4" = 1'-0"A-101CT
4 FLOOR PLAN - THIRD FLOOR
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
PLAN NORTH
1/4" = 1'-0"A-101CT
2 ROOF PLAN
1/4" = 1'-0"A-101CT
5 REFLECTED CEILING PLAN
F.F - CT
2ND FLOOR - CT
109' - 0"
3RD FLOOR - CT
118' - 2"
B.O. SOFFIT - CT
127' - 6"
CT ACT B
RIDGE CAP
SSMR
WARNING LIGHT
POLE (TYP.)
(SEE ELEC)
GUARDRAIL
4" TOEBOARD
(TYP.)
STEEL STAIR
CONCRETE SLAB
12" 2"
T.O. RIDGE - CT
130' - 10"
INSUL. MTL. WALL
PANEL
WARNING LIGHT
POLE (TYP.)
ATTACHMENT
(SEE STRUCT)
T Y
P
A-581
RED & WHITE LIGHT
4' - 3 1/2"
4' - 3 1/2"
(TYP.)
3' - 0"
F.F - CT
100' - 0"
2ND FLOOR - CT
109' - 0"
3RD FLOOR - CT
118' - 2"
B.O. SOFFIT - CT
127' - 6"
CT A CT B
RIDGE CAP
SSMR
GUARDRAIL
GUARDRAIL
MTL. GRATE
STEEL STAIR
CONCRETE SLAB
12" 2"
T.O. RIDGE - CT
130' - 10"
4" TOEBOARD
(TYP.)
RED & WHITE
LIGHTS (TYP.)
4' - 3 1/2"
4' - 3 1/2"
F.F - CT
100' - 0"
2ND FLOOR - CT
109' - 0"
3RD FLOOR - CT
118' - 2"
B.O. SOFFIT - CT
127' - 6"
CT 1CT 2
RIDGE CAP
SSMR
INSUL. MTL.
WALL PANEL
GUARDRAIL
4" TOEBOARD
(TYP.)
STEEL STAIR
CONCRETE SLAB
T.O. RIDGE - CT
130' - 10"
A-581
4' - 5"
4' - 2 1/2"
F.F - CT
100' - 0"
2ND FLOOR - CT
109' - 0"
3RD FLOOR - CT
118' - 2"
B.O. SOFFIT - CT
127' - 6"
CT 1 CT 2
RIDGE CAP
SSMR
INSUL. MTL.
WALL PANEL
GUARDRAIL
4" TOEBOARD
(TYP.)
STEEL STAIR
CONCRETE SLAB
T.O. RIDGE - CT
130' - 10"
T Y
P
HVAC UNIT
(SEE MECH.)
4' - 5"
4' - 2 1/2"
GENERAL ELEVATION NOTES:
1. SEE A-101XX FOR STRUCTURAL GRID DIMENSIONS.
2. SEE A-600 FOR WINDOW TYPES, LOUVER TYPES AND
DOOR NUMBERS NOT SHOWN ON THE ELEVATIONS.
3. SEE ROOF PLANS FOR SIZES AND LOCATIONS OF
OTHER ROOF ELEMENTS.
1 SMOOTH FACE FAMILIAR BEIGE SHERWIN WILLIAMS SW6093
2 SPLIT FACE 8" x 16" FAMILIAR BEIGE GENERAL SHALE
3 SSMR/SOFFIT/FASCIA COLONIAL RED MBCI
4 METAL PANEL/LOUVERS BROWNSTONE MBCI
5 METAL TRIM (DOORS/FRAMES) FOOTHILLS SHERWIN WILLIAMS SW7514
6 ALUM WINDOWS CLEAR ANODIZED AA-M12C22A41
7 STRUCTURAL STEEL FOOTHILLS SHERWIN WILLIAMS SW7514
MARK: FINISH: PATTERN: COLOR: NOMENCLATURE:
COLOR FINISH LEGEND
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
A-200CT
B U
IL
D
IN
G
E L E
V A
T
IO
N S
A U
T O
M A
T E
D I N
F A
N T
R Y
P L A
T O
O N
B A
T T
L E
C O
U R
S E
O M
A H
A D
IS
T
R
IC
T O
M A
H A
N
E B
R A
S K
A
A M
P
A M
P
B R
G
B R
G
/2
/2
W F
-1 -R
-0
F -9
-0
F O
R T
C A
R S
O N
C
O L O
R A
D O
P N
F
Y
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
1/4" = 1'-0"A-200CT
1 NORTH ELEVATION
1/4" = 1'-0"A-200CT
2 SOUTH ELEVATION
1/4" = 1'-0"A-200CT
3 EAST ELEVATION
1/4" = 1'-0"A-200CT
4 WEST ELEVATION 4' 8'0 2'
F.F - CT
2ND FLOOR - CT
109' - 0"
3RD FLOOR - CT
118' - 2"
B.O. SOFFIT - CT
127' - 6"
CT 1CT 2
A-400CT
SSMR ROOF
GUARDRAIL
RIDGE CAP
METAL FASCIA
CONCRETE SLAB
METAL SOFFIT
INSULATED METAL
WALL PANEL
STEEL STAIR
HOLLOW TUBE
STEEL COLUMN
- SEE STRUCTURAL
A-580
INSULATED METAL
SOFFIT PANEL
F.F - CT
100' - 0"
2ND FLOOR - CT
109' - 0"
3RD FLOOR - CT
118' - 2"
B.O. SOFFIT - CT
127' - 6"
CT A CT B
A-400CT
T.O. RIDGE - CT
130' - 10"
GENERAL NOTES:
1. DO NOT SCALE FROM DRAWINGS.
2. SEE CIVIL SITE PLAN FOR BUILDING LOCATION
3. CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ALL WINDOW, DOOR, LOUVER, AND
OTHER OPENINGS PRIOR TO MANUFACTURING OR INSTALLING ANY SUCH ITEM.
ALL OPENINGS SIZES ARE NOMINAL. CONTRACTOR SHALL VERIFY THE ACTUAL SIZE
REQUIRED FOR EACH OPENING.
4. ALL JOINTS & PENETRATIONS TO RECEIVE FLASHING, CAULK, GASKETS, SEALANTS,
OR WEATHERSTRIPPING AS REQUIRED.
5. SEE STRUCTURAL DRAWINGS FOR BEARING HEIGHTS & FRAMING
INFORMATION.
6. ALL FASTENERS TO BE SELECTED FOR DURABILITY IN LOCAL CLIMATE.
7. SEE STRUCTURAL DRAWINGS FOR CONCRETE FLOOR SLAB AND
FOUNDATION INFORMATION.
8. ALL WINDOWS & DOORS SHALL BE THERMALLY INSULATED UNITS.
9. ALL INSULATION & VAPOR BARRIERS TO BE INSULATED PER. MFGR INSTRUCTIONS.
ENSURE A TIGHT BUILDING ENVELOPE.
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
A-300CT
B U
IL
D
IN
G
S E
C T
IO
N
S
A U
T O
M A
T E
D I N
F A
N T
R Y
P L A
T O
O N
B A
T T
L E
C O
U R
S E
O M
A H
A D
IS
T
R
IC
T O
M A
H A
N
E B
R A
S K
A
A M
P
A M
P
B R
G
B R
G
/2
/2
W F
-1 -R
-0
F -9
-0
F O
R T
C A
R S
O N
C
O L O
R A
D O
P N
F
Y
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
1/4" = 1'-0"A-300CT
1 BUILDING SECTION
1/4" = 1'-0"A-300CT
3RD FLOOR - CT
118' - 2"
CT 1
SSMR
METAL DECKING
METAL FRAMING
METAL TRUSS
SEE STRUCTURAL
PRE-FINISHED METAL SOFFIT
PRE-FINISHED METAL FASCIA
CEILING AS INDICATED PER ROOM
FINISH SCHEDULE
2" INSUL. MTL.
WALL PANEL
BEAM, SEE STRUCTURAL
RIGID INSULATION
STEEL GALVANIZED
GUARD RAIL (BEYOND)
STEEL GALVANIZED
GRATING
A-522
A-501
OPP.
R-12 BATT INSULATION
3RD FLOOR - CT
118' - 2"
B.O. SOFFIT - CT
127' - 6"
CT B
STEEL COLUMN
- SEE STRUCTURAL
STEEL BEAM
-SEE STRUCTURAL
CONCRETE ON
METAL DECKING
-SEE STRUCTURAL
SSMR
METAL DECKING
METAL FRAMING
METAL TRUSS
SEE STRUCTURAL
PRE-FINISHED METAL SOFFIT
PRE-FINISHED METAL FASCIA
CEILING AS INDICATED PER ROOM
FINISH SCHEDULE
2" INSUL. MTL.
WALL PANEL (TYP.)
BEAM, SEE STRUCTURAL
RIGID INSULATION
SNOW GUARD
A-523
INTERIOR MTL.
WALL PANEL (TYP)
R-12 BATT INSULATION (TYP.)
ALUM. WINDOW (TYP.)
R-18 BATT
INSULATION (TYP.)
2" EXTERIOR INSULATED
METAL PANEL (TYP.)
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
A-400CT
W A
L L S
E C
T
IO
N S
A U
T O
M A
T E
D I N
F A
N T
R Y
P L A
T O
O N
B A
T T
L E
C O
U R
S E
O M
A H
A D
IS
T
R
IC
T O
M A
H A
N
E B
R A
S K
A
A M
P
A M
P
B R
G
B R
G
/2
/2
W F
-1 -R
-0
F -9
-0
F O
R T
C A
R S
O N
C
O L O
R A
D O
P N
F
Y
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
1" = 1'-0"A-400CT
1 WALL SECTION 1 - CT
1" = 1'-0"A-400CT
2 WALL SECTION 2 - CT 0 1' 2'
CONTROL ROOM
CH4
MWC1
MWC1
FURNITURE LEGEND
CH - CHAIRS:
CH1 ERGONOMIC TASK CHAIR
CH2 SIDE CHAIR
CH3 FOLDING CHAIR
CH4 INSTRUCTOR STOOL
D - DESKS:
D1 L-SHAPED DESK
FT - TABLES:
FT1 FOLDING TABLES
M - MISCELLANEOUS ITEMS:
MLE1 LECTERN
MSS1 OPEN INDUSTRIAL SHELVING
MWB1 WORKBENCH
MWC1 WASTEBASKET, SMALL
MWC2 WASTEBASKET, TALL
SC - STORAGE CABINETS:
SC1 METAL STORAGE/WARDROBE CABINET
SC2 LARGE METAL STORAGE CABINET
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
I-101CT
C O
N
TR
O L
TO
W
ER
(T
H
IR
D F
LO
O
R
FU
R
N
IT
U R
E
PL
AN
AU
TO
M
AT
ED
IN
FA
N
TR
Y
PL
AT
O O
N B
A T
TL
E C
O U
R
SE
O M
A H A
D
IS
T R
IC
T O
M
AH
A, N
EB
R
AS
KA
LO
H
LO
H
LO
H
BR
G
/2
7/
W
F-
-R
-0
F1
-9 7-
FO
R
T C
AR
SO
N , C
O
LO
R
AD
O
PN
7 2
(F
Y 1 7)
1/4" = 1'-0"I-101CT
1 CONTROL TOWER FURNITURE PLAN
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
CONTROL ROOM
T
MS-5
MU-5
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
M-103CT
R
AN
G E
C O
N
TR
O L
R O
O M
H
VA
C P
LA
N
AU
TO
M
AT
ED
IN
FA
N
TR
Y
PL
AT
O O
N B
A T
TL
E C
O U
R
SE
O M
A H A
D
IS
T R
IC
T O
M
AH
A, N
EB
R
AS
KA
K.
P
AR
K
K.
P
AR
K
M
IC
H
AE
L T.
S M
IT
H
, P .E
M . S
M
IT
H
/2
7/
W
F-
-R
-0
F1
-9 7-
FO
R
T C
AR
SO
N , C
O
LO
R
AD
O
PN
7 2
(F
Y 1 7)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
1/4" = 1'-0"M-103CT
1 RANGE CONTROL ROOM 105 HVAC PLAN
SPLIT SYSTEM HEAT PUMP OUTDOOR
UNIT MU-5. MOUNT ON
MANUFACTURER'S STANDARD
EQUIPMENT PAD.
PROGRAMMABLE
THERMOSTAT FOR MS-5
TO BE MOUNTED 5 FT
A.F.F ON INSULATED PAD
SPLIT SYSTEM HEAT PUMP INDOOR
UNIT MS-5 TO BE MOUNTED ON WALL
7 FT A.F.F. PROVIDE CONDENSATE
DRAIN PUMP IF NOT PROVIDED WITH
EQUIPMENT. ROUTE CONDENSATE
DRAIN DOWN TO GRADE AND
TERMINATE ON SPLASH BLOCK.
DRAIN PIPING SHALL BE SECURED TO
BUILDING STRUCTURE AT INTERVALS
NOT TO EXCEED 5 FEET WITH
PROTECTIVE COVER. DO NOT
DISCHARGE CONDENSATE DRAIN
ONTO WALKWAYS OR ROUTE PIPING
ACROSS WALKWAYS.
MDP
CT-1
Panel CT
CT-2
CONTROL ROOM
CT-12
COMM
CABINET
,14
CT-4,6
CT-3,5
MS-5
MU-5
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
E-101CT
C O
N
TR
O L
TO
W
ER
P
L A N
S
AU
TO
M
AT
ED
IN
FA
N
TR
Y
PL
AT
O O
N B
A T
TL
E C
O U
R
SE
O M
A H A
D
IS
T R
IC
T O
M
AH
A, N
EB
R
AS
KA
B.
W
LA
SC
H
IN
B.
W
LA
SC
H
IN
S.
O
TT
S.
O
TT
/2
7/
W
F-
-R
-0
F1
-9 7-
FO
R
T C
AR
SO
N , C
O
LO
R
AD
O
PN
7 2
(F
Y 1 7)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
1/4" = 1'-0"E-101CT
1 CONTROL TOWER POWER PLAN - 1ST FLOOR
1/4" = 1'-0"E-101CT
2 CONTROL TOWER POWER PLAN - 3RD FLOOR
1/4" = 1'-0"E-101CT
3 CONTROL TOWER GROUNDING PLAN
GENERAL NOTES:
1. ALL UNDERGROUND CONDUCTOR BONDS SHALL BE EXOTHERMICALLY
WELDED.
2. LIGHTNING PROTECTION SYSTEM SHALL BE PROVIDED BY A QUALIFIED
CONTRACTOR.
3. REFER TO SHEETS EL501 AND EL502 FOR LUMINAIRE SCHEDULE AND
LUMINAIRE DETAILS.
4. REFER TO SHEET EP602 FOR PANEL SCHEDULES.
5. PROVIDE STRUCTURAL MOUNTING WITH METAL BRACES THAT RIGIDLY
SUPPORT BOXES/FIXTURES.
6. NFPA 780, CLASS II MATERIALS SHALL BE PROVIDED FOR THE
LIGHTNING PROTECTION SYSTEM. MAIN CONDUCTOR: #2/0 AWG MIN.
7. EXPOSE CONDUIT WITH SURFACE MOUNTED DEVICES, OUTLETS, AND
PANELS WHENEVER POSSIBLE.
8. ASSURE EQUIPMENT, DEVICES, BOXES, CONDUIT BODIES, AND
HANDHOLE ENCLOSURES ARE ACCESSIBLE AND/OR READILY
ACCESSABLE AS REQUIRED BY NFPA 70.
9. CONNECT LIGHTNING PROTECTION SYSTEM TO SNOW RETENTION
DEVICES WHEN APPLICABLE.
10. REFER TO SHEET EG501 FOR LIGHTNING PROTECTION AND
GROUNDING DETAILS.
KEYED NOTES:
1. EXOTHERMICALLY WELDED CONNECTION. CONNECTIONS WITHIN
GROUND WELLS MUST BE BOLTED. TYPICAL.
2. 3/4" DIAMETER X 12' - 0" COPPER CLAD GROUND ROD AND GROUNDING
WELL. SEE SHEET EG501. TYPICAL.
3. #2/0 AWG COPPER BUILDING PERIMETER COUNTERPOISE CONDUCTOR,
TYPICAL. BURIAL DEPTH SHALL BE…