Am-0004-DRAWINGS.pdf
PDF 10 MB Posted
- Attached to
- Automated Infantry Platoon Battle Course (IPBC) for Ft. Carson, CO Federal contract opportunity
- Solicitation number
- W9128F17R0078
About this file
Amendment 0004 Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Am-0006_W9128F-17-R-0078.pdf | ||
| Am-0004_W9128F-17-R-0078.pdf | ||
| FCBAC-GP2D01.dgn | — | |
| FCBAV-SP0002.dgn | — | |
| FCBAV-SP0002.dgn | — | |
| Am-0003-W9128F-17-R-0078.pdf | ||
| FCBAC-GP0001.dgn | — | |
| FCBAC-SP0001.dgn | — | |
| FCBAC-SP2D01.dgn | — | |
| FCBAC-GP0001.dgn | — | |
| FCBAC-SP0001.dgn | — | |
| FCBAC-SP2D01.dgn | — | |
| Am-0003-DRAWINGS.pdf | ||
| FCBAC-GP2D01.dgn | — | |
| Am-0002_W9128F-17-R-0078.pdf | ||
| Am-0002-DRAWINGS.pdf | ||
| Am-0001_W9128F-17-R-0078.pdf | ||
| FCBA__ADVERTISEMENT.PDF | ||
| FCBA__ADVERTISEMENT_-_HALF_SIZE.pdf | ||
| RTA-SPECS_W9128F-17-R-0078_AIPBC_Fort-Carson.pdf |
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
A U
T O
M A
T E
D I
N F
A N
T R
Y P
L A
T O
O N
B A
T T
L E C
O U
R S
E
P N
F
Y
F O
R T C
A R
S O
N
C O
L O
R A
D O
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
O M
A H
A
N E
B R
A S
K A
F -9
-0
A N
S I
D
1.
NOTES:
TO BE INSTALLED IN A CONCRETE ENCASED DUCT BANK.
LOCATIONS OTHER THAN DEFINED WILL REQUIRE THE CONDUCTORS
ELECTRICAL OR COMMUNICATION LINES CROSSING ROADS AT
CROSSINGS. ANY DEVIATIONS TO DESIGN THAT RESULT IN
CONCRETE ENCASED DUCT BANK IS REQUIRED AT ALL ROAD
2.SEE SHEET ES301 FOR TRENCHING DETAILS.
3. D W
N B
Y
C K
D B
Y
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
B A
T T
L E C
O U
R S
E
P N
F
Y
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
O M
A H
A
N E
B R
A S
K A
A C
R
C S
N
/2
/2
ES101
ES102
ES103
ES104
ES105
ES106
ES107
ES108
ES109
ES110
ES111
ES112
ES113
ES114
ES115
ES116
ES117ES118ES120
ES119
NN
D E
S
IG
N E
D B
Y
D A
T E
D E
S
IG
N E
D B
Y
D A
T E
®of Engineers
US Army Corps of Engineers
US Army Corps
N
DOWNRANGE KEY PLAN
100'0 50'
SCALE:1"=50'
N
3.
J T
Z
J R
D W
F -1
-R -0
BURIAL. SEE DETAIL 4 AND 5 ON SHEET ES301.
ALL RANGE POWER CABLES BEYOND OBJECTIVE B TO BE BY DIRECT
BE LOCATED IN FRONT OF BERMS OR AREAS SUBJECT TO GUN FIRE.
LOCATION OF DUCT BANK AND HANDHOLES. HANDHOLES SHALL NOT
AND HAND HOLES SHOWN ARE DIAGRAMMATIC. FIELD VERIFY
SHEET ES301 FOR TRENCHING DETAILS. LOCATION OF DUCT BANK
ES403 FOR CONDUIT QUANTITIES AND SIZES. SEE DETAIL 1 AND 3 ON
CONTROL TOWER TO OBJECTIVE B. SEE SHEETS ES401, ES402 AND
PROVIDE NEW DUCT BANK FOR DOWNRAGNE POWER CABLES FROM
UP
TPX
T
US(X)
yF(X)
PAD MOUNTED TRANSFORMER
UNDERGROUND PRIMARY FEEDER DUCT BANK
UNDERGROUND SECONDARY SERVICE
'X' INDICATES SIZE IN AWG
'X' INDICATES No. OF STRANDS
IF 'X' NOT INDICATED 6 STRAND CABLE TO BE INSTALLED
'y' INDICATES No. OF CABLES
IF 'Y' NOT INDICATED ONE CABLE TO BE INSTALLED
Electrical Site Legend
NEW COMMUNICATIONS HANDHOLE REFER TO DETAIL 5/ES302
EHH
THH
PHH NEW PRIMARY HANDHOLE REFER TO DETAIL 1/ES302
DETAIL 5/ES302
NEW SECONDARY ELECTRICAL HANDHOLE REFER TO
FIBER OPTIC CABLE RATED FOR DIRECT BURIAL
UT UNDERGROUND 25-PAIR TELEPHONE CABLE
CONCRETECONCRETECONCRETE
THH
EHH
PHH
T1
UF
UP
US(2)
UP
2F(6)
US(2)
UP
ES580
ES580
TOWER
CONTROL
TOWER
CAMERA
ES101
E L E
C T
R
IC
A L S
IT
E P
L A
N
P N
C A
R S
O N
IP
B C
E
S
A M G
E N
E R
A L R
E V
IS
IO
N S
-9 -2
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
WOOD SHELTER
BRICK BUILDINGR127 AC
BRICK BUILDING
BRICK BUILDINGR127 AB
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T
OMAHA DISTRICT
A U
T O
M A
T E
D I
N F
A N
T R
Y P
L A
T O
O N
B A
T T
L E C
O U
R S
E
N
P N
F
Y
F O
R T C
A R
S O
N
C O
L O
R A
D O
F C
B A
E S .d g n
B .W
L A
S C
H
IN
B .W
L A
S C
H
IN
ES404
S .O
T T
UP
TPX
T
PAD MOUNTED TRANSFORMER
Electrical Site Legend
SEE SHEET ES121
/2
/2
F -9
-0
W F -1
-R -0
40'10'0 20'
E L E
C T
R
IC
A L S
IT
E P
L A
N
R O
C A
T yF(x)
IF "y" IS NOT INDICATED, ONE CABLE TO BE INSTALLED "y" INDICATES THE NUMBER OF CABLES IF "x" IS NOT INDICATED, 6 STRANDS TO BE INSTALLED "x" INDICATES THE NUMBER OF STRANDS
FIBER OPTIC CABLE RATED FOR DIRECT BURIAL
DIRECT BURIAL
UNDERGROUND PRIMARY FEEDER CABLE RATED FOR
EL501 AND EL502.
IN-GRADE LIGHT FIXTURE FOR FLAGPOLE. SEE SHEETS
BANK DETAILS.
2. SEE SHEET ES301 FOR DIRECT BURIAL AND CONCRETE ENCASED DUCT
TO BE INSTALLED IN A CONCRETE ENCASED DUCT BANK.
LOCATIONS OTHER THAN DEFINED WILL REQUIRE THE CONDUCTORS
ELECTRICAL OR COMMUNICATION LINES CROSSING ROADS AT
CROSSINGS. ANY DEVIATIONS TO DESIGN THAT RESULT IN
1. CONCRETE ENCASED DUCT BANK IS REQUIRED AT ALL ROAD
NOTE:
TOWER. SEE SHEETS ES101 AND ES102.
2. SUPPLY POWER FOR A-SIT-1 AND A-SIT-2 FROM CONTROL
PRIMARY SERVICE. SEE SHEETS ES101 AND ES580.
TOWER TO CAMERA TOWER ALONG SAME ROUTE AS
1. DIRECT BURY POWER AND DATA CABLES FROM CONTROL
KEYED NOTES:
SCALE: 1" = 20'
PHH NEW PRIMARY HANDHOLE, SEE SHEET ES302.
THH NEW COMMUNICATIONS HANDHOLE, SEE SHEET ES302.
EHH
ES302.
NEW SECONDARY ELECTRICAL HANDHOLE, SEE SHEET
PHH
EHH
EHH
THH
F
UP
US
SHEET EP601 FOR SIZING
UNDERGROUND SECONDARY FEEDER CABLE SEE
UP
US
2F
US
US
US
US
US
US
US
US
S .O
T T
A M G
E N
E R
A L R
E V
IS
IO
N S
/2
/1
S .O
T T
A M G
E N
E R
A L R
E V
IS
IO
N S
S .O
T T
/0
/1
/0
/1
A
M G
E N
E R
A L R
E V
IS
IO
N S
S .O
T T
F
F
F
TOWER
CONTROL
LATRINE
FIELD
CLASSROOM
OPS/STORAGE
AA
T1
SHEET EP602 FOR PANEL CT SCHEDULE.
SHEETS E-101CT PANELBOARD, E-102CT FOR SWITCH, AND
TOWER ROOM 105 (CONTROL ROOM), THEN TO PANEL 'CT'. SEE
CIRCUIT FLOODLIGHT "AA" TO "FLAGPOLE" SWITCH IN CONTROL
RANGE FLAGPOLE
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
WOOD SHELTER
BRICK BUILDINGR127 AC
BRICK BUILDING
BRICK BUILDINGR127 AB
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T
OMAHA DISTRICT
A U
T O
M A
T E
D I
N F
A N
T R
Y P
L A
T O
O N
B A
T T
L E C
O U
R S
E
N
P N
F
Y
F O
R T C
A R
S O
N
C O
L O
R A
D
UP
TPX
T
PAD MOUNTED TRANSFORMER
Electrical Site Legend
SEE SHEET ES121
40'10'0 20'
T yF(x)
IF "y" IS NOT INDICATED, ONE CABLE TO BE INSTALLED "y" INDICATES THE NUMBER OF CABLES IF "x" IS NOT INDICATED, 6 STRANDS TO BE INSTALLED "x" INDICATES THE NUMBER OF STRANDS
FIBER OPTIC CABLE RATED FOR DIRECT BURIAL
DIRECT BURIAL
UNDERGROUND PRIMARY FEEDER CABLE RATED FOR
EL501 AND EL502.
IN-GRADE LIGHT FIXTURE FOR FLAGPOLE. SEE SHEETS
BANK DETAILS.
2. SEE SHEET ES301 FOR DIRECT BURIAL AND CONCRETE ENCASED DUCT
TO BE INSTALLED IN A CONCRETE ENCASED DUCT BANK.
LOCATIONS OTHER THAN DEFINED WILL REQUIRE THE CONDUCTORS
ELECTRICAL OR COMMUNICATION LINES CROSSING ROADS AT
CROSSINGS. ANY DEVIATIONS TO DESIGN THAT RESULT IN
1. CONCRETE ENCASED DUCT BANK IS REQUIRED AT ALL ROAD
NOTE:
TOWER. SEE SHEETS ES101 AND ES102.
2. SUPPLY POWER FOR A-SIT-1 AND A-SIT-2 FROM CONTROL
PRIMARY SERVICE. SEE SHEETS ES101 AND ES580.
TOWER TO CAMERA TOWER ALONG SAME ROUTE AS
1. DIRECT BURY POWER AND DATA CABLES FROM CONTROL
KEYED NOTES:
SCALE: 1" = 20'
PHH NEW PRIMARY HANDHOLE, SEE SHEET ES302.
THH NEW COMMUNICATIONS HANDHOLE, SEE SHEET ES302.
EHH
ES302.
NEW SECONDARY ELECTRICAL HANDHOLE, SEE SHEET
PHH
EHH
EHH
THH
F
UP
US
SHEET EP601 FOR SIZING
UNDERGROUND SECONDARY FEEDER CABLE SEE
UP
US
2F
US
US
US
US
US
US
US
US
F C
B A
E S
A .d g n
L A
S C
H
IN
B .W
L A
S C
H
IN
ES404A
S .O
T T
O N
E -L
IN
E O
P T
IO
N
R O
C A
S .O
T T
A M N
E W S
H E
E T
/2
/1
S .O
T T
A M G
E N
E R
A L R
E V
IS
IO
N S
S .O
T T
/0
/1
/0
/1
A
M G
E N
E R
A L R
E V
IS
IO
N S
S .O
T T
F
F
F
SHEET EP602 FOR PANEL CT SCHEDULE.
SHEETS E-101CT PANELBOARD, E-102CT FOR SWITCH, AND
TOWER ROOM 105 (CONTROL ROOM), THEN TO PANEL 'CT'. SEE
CIRCUIT FLOODLIGHT "AA" TO "FLAGPOLE" SWITCH IN CONTROL
RANGE FLAGPOLE
TOWER
CONTROL
LATRINE
FIELD
CLASSROOM
OPS/STORAGE
AA
T1
COVERED MESS
AMMO BREAKDOWN
BLEACHER ENCLOSURE
MDP
CT-1
Panel CT
CT-2
CONTROL ROOM
CT-12
COMM
CABINET
,14
CT-4,6
CT-4,6
MS-5
MU-5
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
E-101CT
C O
N
TR
O L
TO
W
ER
P
L A N
S
AU
TO
M
AT
ED
IN
FA
N
TR
Y
PL
AT
O O
N B
A T
TL
E C
O U
R
SE
O M
A H A
D
IS
T R
IC
T O
M
AH
A, N
EB
R
AS
KA
B.
W
LA
SC
H
IN
B.
W
LA
SC
H
IN
S.
O
TT
S.
O
TT
/2
7/
W
F-
-R
-0
FO
R
T C
AR
SO
N , C
O
LO
R
AD
O
PN
7 2
(F
Y 1 7)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
G
EN
ER
AL
R E V
IS
IO
N S
-0
2-
AM
G
EN
ER
AL
R
EV
IS
IO
N S
-0
9-
1/4" = 1'-0"E-101CT
1 CONTROL TOWER POWER PLAN - 1ST FLOOR
1/4" = 1'-0"E-101CT
2 CONTROL TOWER POWER PLAN - 3RD FLOOR
1/4" = 1'-0"E-101CT
3 CONTROL TOWER GROUNDING PLAN
GENERAL NOTES:
1. ALL UNDERGROUND CONDUCTOR BONDS SHALL BE EXOTHERMICALLY
WELDED.
2. LIGHTNING PROTECTION SYSTEM SHALL BE PROVIDED BY A UNITED
LABORATORIES LISTED INSTALLER.
3. REFER TO SHEETS EL501 AND EL502 FOR LUMINAIRE SCHEDULE AND
LUMINAIRE DETAILS.
4. REFER TO SHEET EP602 FOR PANEL SCHEDULES.
5. PROVIDE STRUCTURAL MOUNTING WITH METAL BRACES THAT RIGIDLY
SUPPORT BOXES/FIXTURES.
6. NFPA 780, CLASS I MATERIALS SHALL BE PROVIDED FOR THE LIGHTNING
PROTECTION SYSTEM. MAIN CONDUCTOR: #2 AWG MIN.
7. EXPOSE CONDUIT WITH SURFACE MOUNTED DEVICES, OUTLETS, AND
PANELS WHENEVER POSSIBLE.
8. ASSURE EQUIPMENT, DEVICES, BOXES, CONDUIT BODIES, AND
HANDHOLE ENCLOSURES ARE ACCESSIBLE AND/OR READILY
ACCESSABLE AS REQUIRED BY NFPA 70.
9. CONNECT LIGHTNING PROTECTION SYSTEM TO SNOW RETENTION
DEVICES WHEN APPLICABLE.
10. REFER TO SHEET EG501 FOR LIGHTNING PROTECTION AND
GROUNDING DETAILS.
KEYED NOTES:
1. EXOTHERMICALLY WELDED CONNECTION. CONNECTIONS WITHIN
GROUND WELLS MUST BE BOLTED. TYPICAL.
2. 3/4" DIAMETER X 12' - 0" COPPER CLAD GROUND ROD AND
GROUNDING WELL. SEE SHEET EG501. TYPICAL.
3. #2 AWG COPPER BUILDING PERIMETER COUNTERPOISE
CONDUCTOR, TYPICAL. BURIAL DEPTH SHALL BE 36", MIN.
4. ASSURE ALL GROUNDING MEDIA IN OR ON THE CONTROL TOWER
STRUCTURE IS INTERCONNECTED WITH THE LIGHTNING PROTECTION
SYSTEM TO PROVIDE COMMON GROUND POTENTIAL. THE DOWN
CONDUCTOR SHALL BE RUN DOWN THE COLUMN IN PVC CONDUIT.
TYPICAL.
5. TWO 36" HIGH X 36" WIDE X 12" DEEP WALL MOUNTED
COMMUNICATIONS RACKS, VENTILATED PERFORATED METAL SIDES,
AND FAN MOUNTED AT TOP OF CABINET. MOUNT ONE CABINET 24"
ABOVE THE SECOND CABINET. SEE SHEET TN501.
6. RUN WIREWAY VERTICALLY THROUGH FLOOR AND STUB UP
UNDERNEATH COUNTERTOP AND UNDERNEATH COMM RACK.
7. 24" NICKEL TIPPED, COPPER CLAD AIR TERMINAL. SEE SHEET EG501
FOR MOUNTING. MAIN LIGHTNING PROTECTION CONDUCTOR SIZED #2
AWG MIN. TYPICAL.
8. SPLIT-WIRED 120V RECEPTACLE WITH TWO CIRCUITS MOUNTED IN
COMMUNICATIONS CABINET.
9. 36" W X 48"H X 12"D NEMA 4 CABINET WITH LOCKABLE HASP FOR
COMMUNICATION CABLING. MOUNT TO UNISTRUT STAND.
10. 2 EACH 2" CONDUITS FROM CABINET TO COMMUNICATION RACKS
LOCATED IN CONTROL ROOM.
11. PROVIDE POWER FOR TARGETS A-SIT-1 AND A-SIT-2 FROM PANEL
MDP. SEE SITE SHEETS FOR CIRCUIT ROUTING.
12. DATA JACK FED FROM COMMUNICATIONS CABINET BY FIBER OPTIC
CABLE FROM BUILDING 127AB
13. DATA JACKS FED FROM COMMUNICATIONS CABINET BY FIBER OPTIC
CABLE FROM CAMERA TOWER.
14. 3/4" CONDUIT WITH 6 STRAND OPTIC CABLE TO OPS/STORAGE DATA
SWITCH.
15. GROUND COMM RACK CABINET GROUND BAR TO STRUCTURAL
STEEL USING #6 AWG.
16. PROVIDE 60A AND 20A CIRCUITS (CT-7,9 AND CT-8) TO CAMERA
TOWER FOR POWER AND CONTROLS. USE SAME TRENCH AS PRIMARY
POWER.
17. #4/0 AWG GROUND CONNECTION FROM PANEL MDP TO PERIMETER
COUNTERPOISE.
1 2
11 12
COMM
4' 8'0 2'
PLAN NORTH
MDP
CT 1
CT 2
CT A CT B
CONTROL ROOM
A
A
AA
A
A
B B
BB
B B
K
H
CT-10
F
K
F
CT-11
CT-9
"FLAGPOLE"
CT-10
K
F F
K
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
E-102CT
C O
N
TR
O L
TO
W
ER
P
L A N
S
AU
TO
M
AT
ED
IN
FA
N
TR
Y
PL
AT
O O
N B
A T
TL
E C
O U
R
SE
O M
A H A
D
IS
T R
IC
T O
M
AH
A, N
EB
R
AS
KA
B.
W
LA
SC
H
IN
B.
W
LA
SC
H
IN
S.
O
TT
S.
O
TT
/2
7/
W
F-
-R
-0
FO
R
T C
AR
SO
N , C
O
LO
R
AD
O
PN
7 2
(F
Y 1 7)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
G
EN
ER
AL
R E V
IS
IO
N S
-0
9-
1/4" = 1'-0"E-102CT
2 CONTROL TOWER LIGHTING PLAN - 3RD FLOOR
1/4" = 1'-0"E-102CT
1 CONTROL TOWER LIGHTING PLAN - 1ST FLOOR
GENERAL NOTES:
1. REFER TO SHEETS EL501 AND EL502 FOR LUMINAIRE SCHEDULE AND
LUMINAIRE DETAILS.
2. REFER TO SHEET EP602 FOR PANEL SCHEDULES.
3. PROVIDE STRUCTURAL MOUNTING WITH METAL BRACES THAT RIGIDLY
SUPPORT BOXES/FIXTURES.
4. EXPOSE CONDUIT WITH SURFACE MOUNTED DEVICES, OUTLETS, AND
PANELS WHENEVER POSSIBLE.
5. ASSURE EQUIPMENT, DEVICES, BOXES, CONDUIT BODIES, AND
HANDHOLE ENCLOSURES ARE ACCESSIBLE AND/OR READILY
ACCESSABLE AS REQUIRED BY NFPA 70.
KEYED NOTES:
1. 3-WAY SWITCHES FOR RED AND WHITE EXTERIOR LIGHTS, LOCATED
AT THE BASE OF THE STAIRS AND INSIDE THE DOOR TO THE CONTROL
ROOM.
2. RED AND WHITE LIGHTING SHALL BE SEPARATELY SWITCHED. LABEL
LIGHT SWITCHES PER USE "RED-INTERIOR", "WHITE-INTERIOR", "RED-
EXTERIOR", "WHITE-EXTERIOR". PROVIDE "WHITE" SWITCH
WEATHERPROOF COVERS WITH A LOCKING TAB. SEE SHEET EL501.
3. MOUNT FIXTURES 8' ABOVE WALKWAY OR STAIRS. TYPICAL.
4. SUPPLY FROM PANEL "CT". SEE SHEET E-101CT DETAIL 2 FOR PANEL
LOCATION AND SHEET EP602 FOR SCHEDULE.
5. TO LOAD "AA" FLAGPOLE FLOODLIGHT. SEE SHEET ES404 FOR
LOCATION.
1 2
1 2
4' 8'0 2'
PLAN NORTH
G G
STORAGE
OFFICE
Panel OS
OS-2
OS-3
OS-12
OS-4,6
OS-4,6
OS-12,14
OS-8,10
UH-1
MS-4
MU-4
EF-4
OS-1
WP
G
WP
G
OFFICE
D
D D
D
D
D
D D
D
H
H
F
K
D
OS-11OS-11
F
K
OS-9
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
E-101OS
O
PE
R
AT
IO
N
S /
ST
O R
AG
E
PL
AN
S
AU
TO
M
AT
ED
IN
FA
N
TR
Y
PL
AT
O O
N B
A T
TL
E C
O U
R
SE
O M
A H A
D
IS
T R
IC
T O
M
AH
A, N
EB
R
AS
KA
B.
W
LA
SC
H
IN
B.
W
LA
SC
H
IN
S.
O
TT
S.
O
TT
/2
7/
W
F-
-R
-0
FO
R
T C
AR
SO
N , C
O
LO
R
AD
O
PN
7 2
(F
Y 1 7)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
N
EW
D R
AW
IN
G A
D D
ED
-0 2-
AM
G
EN
ER
AL
R
EV
IS
IO
N
S
-0 9-
1/4" = 1'-0"E-101OS
1 OPERATIONS/STORAGE POWER PLAN
1/4" = 1'-0"E-101OS
2 OPERATIONS/STORAGE LIGHTING PLAN
1/4" = 1'-0"E-101OS
3 OPERATIONS STORAGE GROUNDING PLAN
GENERAL NOTES:
1. ALL UNDERGROUND CONDUCTOR BONDS SHALL BE
EXOTHERMICALLY WELDED.
2. LIGHTNING PROTECTION SYSTEM SHALL BE PROVIDED BY A UNITED
LABORATORIES LISTED INSTALLER.
3. REFER TO SHEETS EL501 AND EL502 FOR LUMINAIRE SCHEDULE AND
LUMINAIRE DETAILS.
4. REFER TO SHEET EP602 FOR PANEL SCHEDULES.
5. PROVIDE STRUCTURAL MOUNTING WITH METAL BRACES THAT
RIGIDLY SUPPORT BOXES/FIXTURES.
6. NFPA 780, CLASS I MATERIALS SHALL BE PROVIDED FOR THE
LIGHTNING PROTECTION SYSTEM. MAIN CONDUCTOR: #2 AWG MIN.
7. EXPOSE CONDUIT WITH SURFACE MOUNTED DEVICES, OUTLETS, AND
PANELS WHENEVER POSSIBLE.
8. ASSURE EQUIPMENT, DEVICES, BOXES, CONDUIT BODIES, AND
HANDHOLE ENCLOSURES ARE ACCESSIBLE AND/OR READILY
ACCESSABLE AS REQUIRED BY NFPA 70.
9. REFER TO SHEET EG501 FOR LIGHTNING PROTECTION AND
GROUNDING DETAILS.
10. SERVICE ENTRANCE FEEDERS WILL ENTER EXPOSED ON THE
EXTERIOR OF THE BUILDING.
KEYED NOTES:
1. EXOTHERMICALLY WELDED CONNECTION. CONNECTIONS WITHIN
GROUND WELLS MUST BE BOLTED. TYPICAL.
2. 3/4" DIAMETER X 12' - 0" COPPER CLAD GROUND ROD AND GROUNDING
WELL. SEE SHEET EG501. TYPICAL.
3. #2 AWG COPPER BUILDING PERIMETER COUNTERPOISE CONDUCTOR,
TYPICAL. BURIAL DEPTH SHALL BE 36", MIN.
4. ASSURE ALL GROUNDING MEDIA IN OR ON THECOVERED MESS
STRUCTURE IS INTERCONNECTED WITH THE LIGHTNING PROTECTION
SYSTEM TO PROVIDE COMMON GROUND POTENTIAL. THE DOWN
CONDUCTOR SHALL BE RUN DOWN THE COLUMN IN PVC CONDUIT.
TYPICAL.
5. RED AND WHITE LIGHTING SHALL BE SEPARATELY SWITCHED. LABEL
LIGHT SWITCHES PER USE "RED EXTERIOR", "WHITE EXTERIOR", WHITE
INTERIOR. PROVIDE "WHITE SWITCH WEATHERPROOF COVERS WITH A
LOCKING TAB. SEE SHEET EL501.
6. 24" NICKEL TIPPED, COPPER CLAD AIR TERMINAL. SEE SHEET EG501
FOR MOUNTING. MAIN LIGHTNING PROTECTION CONDUCTOR SIZED TO #2
AWG MIN. TYPICAL.
7. 3/4" CONDUIT TO CONTROL TOWER FOR PHONE LINE.
8. DATA SWITCH IN WALL-MOUNTED COMM CABINET ON COMM
BACKBOARD. REFER TO COMMUNICATION DETAILS ON SHEET TN501
FOR ADDITIONAL INFORMATION.
9. PROVIDE 4'W X 8'H X 3/4" THICK PLYWOOD COMMUNICATIONS
BACKBOARD AS INDICATED WITH FIRE RESISTANT INSULATING PAINT
FINISH. MOUNT PLYWOOD BACKBOARD VERTICALLY.
1 2
8 9
4' 8'0 2' 8'0 4' 16'
PLAN NORTH
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
®of Engineers
US Army Corps
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T
OMAHA DISTRICT
A U
T O
M A
T E
D I
N F
A N
T R
Y P
L A
T O
O N
B A
T T
L E C
O U
R S
E
P N
F
Y
F O
R T C
A R
S O
N
C O
L O
R A
LED ENCLOSED AND GASKETED
REVISED: APRIL 2016 NL-11LIGHTING PLATE:
LED RECESSED DOWNLIGHT
REVISED: APRIL 2016 NL-19LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - FIBERGLASS OR FIBERGLASS-REINFORCED POLYESTER OUTER HOUSING, WITH
ALUMINUM COMPONENT TRAY AND HEAT SINK. OPTIONAL LENGTHS OF 4FT OR 8FT.
2. LENS - IMPACT-RESISTANT ACRYLIC OR OPTIONAL POLYCARBONATE, WITH CONTINUOUS
CLOSED-CELL POLYURETHANE GASKET, SECURED WITH STAINLESS STEEL OR
POLYCARBONATE LATCHES.
3. LIGHT SOURCE - SOLID STATE LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70,
4000K CCT UON, MINIMUM 80 CRI, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING
TOLERANCE FOR COLOR CONSISTENCY, AND MINIMUM EFFICACY OF 100 LUMENS/WATT.
INITIAL LUMEN OUTPUT AS INDICATED IN LUMINAIRE SCHEDULE.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC
DISTORTION. ON-OFF CONTROL, STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED.
5. CERTIFICATION - UL 1598, WET LOCATION (IP65, IP66, IP67), DLC QUALIFIED, AND ROHS
COMPLIANT. COMPLIES WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN
EQUIPPED WITH EMERGENCY BATTERY BACK-UP.
6. MOUNTING - SURFACE-MOUNTED OR SUSPENDED FROM CEILING.
7. OPTIONS - POWER CORD, INTEGRAL MOTION SENSOR, EMERGENCY BACK-UP.
8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER OR PREFERENCE.
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD-ROLLED STEEL, OR FORGED ALUMINUM WITH HEAT SINK.
DRIVER MUST BE ACCESSIBLE FROM BOTTOM OF LUMINAIRE. PROVIDE T-BAR HANGERS
FOR INSTALLATION IN ACOUSTICAL TILE CEILINGS OR TABS WHEN MOUNTING IN HARD
CEILINGS.
2. REFLECTOR AND TRIM - SPECIFICATION GRADE, LOW IRRIDESCENT, SPECULAR ALUMINUM
REFLECTOR WITH METALLIC OR PAINTED TRIM RING..
3. LIGHT SOURCE - SOLID STATE LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70,
4000K CCT UON, MINIMUM 80 CRI, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING
TOLERANCE FOR COLOR CONSISTENCY, AND MINIMUM EFFICACY OF 90 LUMENS/WATT.
INITIAL LUMEN OUTPUT AS INDICATED IN LUMINAIRE SCHEDULE.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC
DISTORTION. ON-OFF CONTROL, STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED.
5. CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT.
COMPLIES WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN EQUIPPED
WITH EMERGENCY BATTERY BACK-UP.
6. MOUNTING - RECESSED IN HARD OR ACOUSTICAL TILE CEILING.
7. OPTIONS - EMERGENCY BATTERY BACK-UP, WALL-WASH TRIM, IC RATED FOR DIRECT
CONTACT WITH INSULATION, VARIOUS APERTURE DIAMETERS, AND VARIOUS GLASS LENSES.
8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER OR PREFERENCE.
F C
B A
E L .d g n
A B
S .O
T T
S .O
T T
/0
/1
A
M G
E N
E R
A L R
E V
IS
IO
N S
S .O
T T
B .W
L A
S C
H
IN
B .W
L A
S C
H
IN
EL501
L
IG
H T
IN
G S
C H
E D
U L E A
N D L
IG
H T
IN
G D
E T
A
IL
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
®of Engineers
US Army Corps
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T
OMAHA DISTRICT
F C
B A
E L .d g n
A U
T O
M A
T E
D I
N F
A N
T R
Y P
L A
T O
O N
B A
T T
L E C
O U
R S
E
P N
F
Y
F O
R T C
A R
S O
N
C O
L O
R A
LED INDUSTRIAL STRIP
REVISED: APRIL 2016 NL-7LIGHTING PLATE:
HOUSING - DIE-CAST ALUMINUM OR HIGH-IMPACT, UV-STABILIZED, INJECTION-MOLDED
FINISH (ON CAST ALUMINUM HOUSING ONLY) - TEXTURED POWDER COAT FINISH
OPTIONS INCLUDE WHITE, WHITE WITH BRUSHED ALUMINUM FACE, BLACK, OR BLACK
EMERGENCY PACK - SOLID-STATE, CONSTANT-CURRENT TYPE BATTERY CHARGER WITH
MOUNTING - UNIVERSAL MOUNTING KIT FOR CEILING, WALL OR END-OF-FIXTURE
ILLUMINATION - PROVIDED BY RED, GREEN OR WHITE HIGH-OUTPUT LEDS INSIDE
1.
2.
3.
4.
5.
6.
LUMINAIRE REQUIREMENTS:
REVISED: AUGUST 2004 NL-63
MOUNTING.
THERMOPLASTIC. SINGLE OR DOUBLE-FACED AS INDICATED.
MAINTENANCE-FREE, NICKEL-CADMIUM BATTERY, AC-ON INDICATOR LAMP AND
LIGHTING PLATE:
LED EXIT SIGN
13"
NOMINAL
NOMINAL
9"
WITH BRUSHED ALUMINUM FACE.
DIRECTIONS AS INDICATED. CHEVRONS PUNCHED OUT THROUGH HOUSING AS REQUIRED.
TEST SWITCH.
OF FIXTURE HOUSING. PROVIDE POLYSTYRENE DIFFUSER IN COLOR INDICATED WITH
FREQUENCY-MATCHED SILKSCREEN COATING FOR MAXIMUM LED LIGHT OUTPUT.
CERTIFICATION - UL LISTED AND CERTIFIED FOR DAMP LOCATIONS.7.
PRISMATIC LENS LED TROFFER
REVISED: APRIL 2016 NL-3LIGHTING PLATE:
D F, K H
G,J
REVISED: AUGUST 2004 XL-12LIGHTING PLATE:
RECESSED IN-GRADE FLOODLIGHT
NOMINAL
16"
NOMINAL
12"
MOUNTING - DIRECT SET IN GRADE, CONCRETE BASE OR PAVED AREEAS FOLLOWING
OPTIONS - HALF SHIELD FOR WALL WASH, TRIM RING, GROUT MASK FOR CONCRETE
AUTOTRANSFORMER, HIGH POWER FACTOR ( .90), CORE AND COIL TYPE MOUNTED
IN WATERPROOF COMPARTMENT.
CERTIFICATION - UL LISTED AND CERTIFIED FOR WET LOCATIONS.
BALLAST - PREWIRED, ENCASED AND POTTED (ENCAPSULATED), CONSTANT-WATTTAGE
LAMPS - METAL HALIDE, HIGH PRESSURE SODIUM, OR HALOGEN WITH WATTAGES AS
LAMP SOCKET - INTEGRAL, PRE-WIRED PORCELAIN LAMP SOCKET WITH NICKEL-
SEPARATE BALLAST AND WIRING COMPARTMENTS. PROVIDE 2 - 3/4" CONDUIT
HOUSING - COMPRESSION OR INJECTION MOLDED, FIBERGLASS COMPOSITE BODY WITH
7.
10.
8.
9.
LUMINAIRE REQUIREMENTS:
4.
6.
3.
1.
INDICATED. PROVIDE BEAM SPREAD PATTERN AS INDICATED. SEE LIGHTING FIXTURE
PLATED SCREW AND CENTER CONTACT FOR MEDIUM BASE LAMPS.
ENTRANCES IN BOTTOM.
LENS - CLEAR, TEMPERED GLASS (FLAT OR CONVEX) WITH ONE-PIECE SILICONE
INSTALLATIONS, COLORED LENSES, AND PRISMATIC OR SPREAD LENSES.
SCHEDULE.
2. LENS RING - ONE-PIECE CAST ALUMINUM OR BRONZE WITH CAPTIVE STAINLESS STEEL
SCREWS OR TAMPERPROOF FASTENER.
GASKETING.
REFLECTOR - SPUN OR HYDROFORMED SPECULAR (FOR SPOT) OR DIFFUSE (FOR5.
FLOOD OR WASH) ALUMINUM WITH ADJUSTABLE TILT AND 360 DEGREES OF ROTATION
WITH LOCKING SCREWS.
MAUNUFACTURER'S RECOMMENDATIONS.
AA
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-CAST OR EXTRUDED ALUMINUM WITH INTEGRAL PASSIVE COOLING MECHANISM.
HEAT SINK SHALL BE INCORPORATED DIRECTLY INTO HOUSING OR DRIVER COMPARTMENT TO
ENSURE MAXIMUM HEAT TRANSFER AND DISSIPATION.
2. FINISH - MULTI-STAGE PRE-TREATMENT, FINISHED WITH BAKED-ON POLYESTER POWDER COAT.
FINISH SHALL PASS 2500 HOUR SALT SPRAY TEST PER ASTM B117. STANDARD FINISH IS DARK
BRONZE, WITH OTHER CUSTOM COLORS AVAILABLE.
3. POWER SUPPLY/LED DRIVER - CLASS 1 DRIVER SHALL OPERATE AT 120/277 VOLTS, 50/60 HZ, WITH OTHER VOLTAGES OPTIONAL; POWER FACTOR GREATER THAN 0.9 AND THD LESS THAN 20%
AT FULL LOAD. MINIMUM EFFICACY SHALL BE 60 LM/W AT MAXIMUM 600mA OPERATING CURRENT.
4. LED OPTICAL ASSEMBLY - PRECISION MOLDED ACRYLIC LENS PROVIDED FOR MULTIPLE
HIGH-POWERED LEDS PRODUCING NEMA TYPE III DISTRIBUTION OR AS OTHERWISE INDICATED. BUG
UPLIGHT RATING OF U0, WITH GLARE RATING AS DETERMINED BY LIGHTING ZONE INSTALLED.
MINIMUM COLOR RENDERING INDEX (CRI) SHALL BE 70 FOR CORRELATED COLOR TEMPERATURE
(CCT) OF 4000-4500 DEGREES K.
5. CERTIFICATION - UL AND/OR ETL LISTED FOR DAMP OR WET LOCATIONS AS INDICATED, AND
RoHS COMPLIANT.
6. OPTIONS - VARIOUS LUMEN OUTPUT RATING AS INDICATED, PHOTOCELL, AND 0-10 VOLT DIMMING
DRIVER.
7. OTHER - THE ABOVE SKETCH IS A NON-PROPRIETY GRAPHIC REPRESENTATION OF A LUMINAIRE
THAT MAY MEET THE SPECIFICATION REQUIREMENTS AND IS NOT INTENDED TO INDICATE A CERTAIN
MANUFACTURER'S PREFERENCE. ALL DIMENSIONS ARE NOMINAL AND VARY PER MANUFACTURER.
REVISED: MARCH 2013 XL-17LUMINAIRE PLATE:
LED WALL PACK
15 IN
10 IN
5 IN
F, K
PROVIDE CHEVRONS AS INDICATED EITHER LEFT, RIGHT OR BOTH
LETTERS/CHEVRONS - MINIMUM 6" HIGH WITH 3/4" STROKE. RED LETTERS.
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD ROLLED STEEL, PAINTED AFTER FABRICATION. EXTRUDED
ALUMINUM DOOR WITH SPRING-LOADED CAM LATCHES. HIGH REFLECTANCE, WHITE
POLYESTER POWDER-COATED FINISH. OPTIONAL SIZES OF 1FT x 4FT, 2FT x 2FT, AND
2FT x 4FT AVAILABLE.
2. LIGHT SOURCE - LED BOARD OR ARRAY WITH MINIMUM 50K HOURS RATED LIFE AT L70,
4000K COLOR TEMPERATURE UON, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING
TOLERANCE FOR COLOR CONSISTENCY, MINIMUM EFFICACY OF 90 LUMENS/WATT, WITH A
MINIMUM CRI OF 80. INITIAL LUMEN OUTPUT AS INDICATED IN LUMINAIRE SCHEDULE.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC
DISTORTION. STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED IN LUMINAIRE
SCHEDULE.
5. CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT.
COMPLIES WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN EQUIPPED
WITH EMERGENCY BATTERY BACK-UP. IC RATED WHEN INDICATED.
6. MOUNTING - RECESSED IN SUSPENDED ACOUSTICAL TILE OR HARD CEILING.
7. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER OR PREFERENCE.
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD-ROLLED STEEL, WITH REINFORCEMENT RIBS FOR RIGIDITY
AND SPECULAR ALUMINUM OR HIGHLY-REFLECTIVE PAINTED STEEL REFLECTORS.
OPTIONAL LENGTHS OF 4FT OR 8FT.
2. FINISH - MULTI-STAGE PHOSPHATE BONDING TREATMENT FINISHED WITH
HIGH-REFLECTANCE, WHITE POLYESTER POWDER COAT, PAINTED AFTER FABRICATION.
3. LIGHT SOURCE - SOLID STATE LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70,
4000K CCT UON, MINIMUM 80 CRI, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING
TOLERANCE FOR COLOR CONSISTENCY, AND MINIMUM EFFICACY OF 100 LUMENS/WATT.
INITIAL LUMEN OUTPUT AS INDICATED IN LUMINAIRE SCHEDULE.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC
DISTORTION. ON-OFF CONTROL, STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED.
5. CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT.
COMPLIES WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN EQUIPPED
WITH EMERGENCY BATTERY BACK-UP.
6. MOUNTING - SURFACE ON CEILING OR SUSPENDED.
7. OPTIONS - WIRE GUARD, CHAIN, STEM OR SWIVEL STEM HANGERS.
8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER OR PREFERENCE.
L A
S C
H
IN
B .W
L A
S C
H
IN
EL502
S .O
T T
L
IG
H T
IN
G D
E T
A
IL
S
S .O
T T
/0
/1
S .O
T T
A M G
E N
E R
A L R
E V
IS
IO
N
NOTES:
1. SEE COLOR CODE SCHEDULE ON THIS SHEET
FOR CABLE AND JACK COLORS.
2. -- INDICATES BLANK PORT.
3. WHERE BLANK PORT EXISTS (--) PROVIDE ONE
(1) PULL WIRE TO NEAREST TELECOM ROOM.
DATAA
STATION LABEL TYPE
DATA (NIPRNET)
VOICE
LETTER
D
V
JACK
ORANGE
BLUE
WHITE
BLUE
CABLE
COMMUNICATIONS COLOR CODE DESIGNATION SCHEDULE
ALL COMM OUTLETS SHALL BE 8-PIN RJ-45 U.O.N.
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8 T3 R3 T2 R1 T1 R2 T4 R4
W /G
R
G R
W /O
R
BL O
R BRW
/B
L
W /B
R
COLOR
PIN
NUMBER
1 WHITE-GREEN
WHITE-ORANGE3
WHITE-BROWN7
T-568A WIRING
CONFIGURATION
GREEN
BLUE
WHITE-BLUE
ORANGE
BROWN
PAIR 3
PAIR 4
PAIR 1PAIR 2
SYMBOL A
COMMUNICATIONS OUTLET
CONFIGURATIONS
PORT
B C DLABEL
VD VD2D
2V
N/A D
D D2D
D VN/A
VW
DETAIL
(TN502)
D D4D 3D D
TN502
DATA OUTLET
NOT TO SCALE
TN502
T-568A WIRING CONFIGURATION
NOT TO SCALE
B
STATION LABEL
TN502
TYPICAL DATA AND VOICE OUTLET MOUNTING DETAIL
NTS
TN502
TYPICAL OUTLET SURFACE MOUNTING DETAIL
NTS
JUNCTION BOX. SEE
SPECIFICATION 26 20 00
FOR MINIMUM SIZES.
SINGLE GANG COVER WITH
JACKS INDICATED. MOUNT
DEVICE COVER ON SURFACE
BOX REDUCER COVER.
CABLES IN 1" CONDUIT MINIMUM.
WALL
BELL BONDING BUSHING AT END OF
CONDUIT BEFORE CABLE TRAY. PROVIDE
#6 BONDING WIRE FROM BUSHING TO
CABLE TRAY GROUND WIRE.
CABLES IN 1"
CONDUIT
MINIMUM.
JUNCTION BOX. SEE
SPECIFICATION 26 20 00 FOR
MINIMUM SIZES.
SINGLE GANG COVER
WITH JACKS INDICATED.
MOUNT DEVICE COVER
FLUSH ON WALL.
GENERAL TELECOMMUNICATIONS NOTES:
(APPLICABLE TO ALL EG TN### SHEETS)
1. REFER TO SHEET TN501 FOR COMMUNICATIONS LETTER DESINATIONS AND JACK AND CABLE COLOR.
2. ALL CABLES SHALL BE SECURED WITH VELCRO TYPE CABLE RETAINERS. NO RATCHET-TYEP CABLE (ZIP) TIES SHALL
BE SUED ON HORIXONTAL CABLING.
3. FIRE SEAL PENETRATION AFTER CABLE INSTALLATION FOR CONDUIT PENETRATIONS THROUGH AIR BARRIERS.
4. JUNCTION BOXES AND ASSOCIATED CONDUIT LOCATED ON PRECAST CONCRETE WALLS SHALL BE SURFACE
MOUNTED.
5. TELECOMMUNICTIONS PENETRATION OPENINGS THROUGH AIR BARRIERS SHALL COMPLY WITH THE BUILDING AIR BARRIER REQUIRMENTS. CORRECT ALL PENETRATIONS THAT ARE DETERMINED DEFICIENT DURING TESTING. SEE
ARCHITECTURE FOR SEALING PENETRATIONS.
6. DO NOT PENETRATE STRUCTURAL COLUMNS, BEAMS, AND TRUSSES. AFIX DEVICES AND RACEWAY WITH BEAM C- CLAMPS, BRACKETS, CLIPS, UNISTRUT, AND OTHER NON-PENETRATING AND NON-ADHESIVE HARDWARE.
7. COORIDNATE TELECOMMUNICATIONS OUTLETS WITH POWER RECEPTACLES (EP DRAWING SERIES). SPACING SHALL
BE NO GREATER THAN 12" CENTER TO CENTER.
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
TN502
TE
LE
C O
M M
U N
IC
AT
IO
N
S D
ET
AI
LS
AU
TO
M
AT
ED
IN
FA
N
TR
Y
PL
AT
O O
N B
A T
TL
E C
O U
R
SE
O M
A H A
D
IS
T R
IC
T O
M
AH
A, N
EB
R
AS
KA
B.
W
LA
SC
H
IN
B.
W
LA
SC
H
IN
S.
O
TT
S.
O
TT
/2
7/
W
F-
-R
-0
F2
-1 5-
FO
R
T C
AR
SO
N , C
O
LO
R
AD
O
PN
7 2
(F
Y 1 7)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
G
EN
ER
AL
R
EV
IS
IO
N S
-0
2-
AM
G
EN
ER
AL
R
EV
IS
IO
N S
-0
9-
WIRE MANAGEMANT 1U
NETWORK SWITCH SPACE 1U
TN601
WALL-MOUNT COMMUNICATION CABINET
NTS
TN601
COMMUNICATIONS CONNECTION DETAIL
NTS
TN601
COMMUNICATIONS RISER DIAGRAM
NTS
BUILDING
127AB
NEW
CHH
THIRD FLOOR
OSP
4. DUCT STUP-UPS FOR DATA AND COMMUNICATIONS CABLING SHALL
BE SEALED. PROVIDE MECHANICAL PLUGS FOR EMPTY DUCTS ON BOTH
ENDS. TEMPORARY MECHANICAL PLUGS SHALL BE PROVIDED FOR
DUCTS UNTIL CABLING IS INSTALLED AND COMPLETED.
1. RISER IS TYPICAL ONLY. SEE FLOOR PLANS FOR EXACT NUMBER
AND LOCATIONS OF OUTLETS AND RACKS.
2. GROUND TTB's RACKS, CABLE TRAYS, ETC., PER ANSI/TIA/EIA 607A.
3. CABLE WIRING CONFIGURATION SHALL BE T-568A.
WIRE
MANAGER
D RINGS
WIRE
MANAGER
D RINGS
BACKBOARD FIRE-
RATED
A-C PLYWOOD
4"
24" (H)
(D) (W) 24"
26"
CONTROL
ROOM
SMFO
CU
PR
OSP
SINGLE-MODE FIBER OPTIC
COPPER
PAIR
OUTSIDE PLANT
KEYED NOTES
GENERAL NOTES
EQUIPMENT ROOM 103
DATA OUTLET
W/ 1- 4 PR CABLE
54" AFF (TYP)
1. 2" CONDUIT AND 2" SPARE. USE DUCT TO RUN 6-STRAND SINGLE-MODE FIBER
OPTIC OUTSIDE PLANT SERVICE ENTRANCE CABLE.
2. 3/4" CONDUIT TO OPS/STORAGE BUILDING, ROOM 110.
3. PRE-DRILLED 1/4"x2"x12" GROUND BAR.
4. DEDICATED DOUBLE DUPLEX RECEPTACLE.
5. 25 FOOT FIBER MAINTENANCE LOOP. 2 FOOT MINIMUM DIAMETER.
7.WALL MOUNT COMMUNICATION CABINET, SEE DETAIL 1 THIS SHEET.
8. SINGLE-SIDED SIZE ONE RACK UNIT HIGH HORIZONTAL WIRE MANAGER.
9. ONE RACK UNIT HIGH, OPTICAL FIBER TERMINATION ENCLOSURE WITH LC
TYPE CONNECTOR.
10. 24-PORT CATEGORY 6-RATED PATCH PANEL FOR DATA STATION CABLES.
GASKETED FRONT DOOR WITH:
KEY LOCK
MAGNETIC CLOSURE
LIFT-OFF HINDGES
SMOKED PLEXIGLASS WINDOW
FAN
KNOCKOUTS
(2)
TWO SIDE
PANELS
NOTES:
3" O.C. CABLE
ENTRY (2)
1. EVEN THOUGH IT ISN'T SHOWN,
PROVIDE BACK HINGE TO ALLOW
REAR ACCESS. LOCKABLE HASP.
SUPPLEMENTAL LEGEND:
DIRECT BURY,
6 STRAND SMFO.
DIRECT BURY,
6 STRAND SMFO.
NEW
CHH
NEW
CHH
NEW
CHH
NEW
CHH
DIRECT BURY,
6 STRAND SMFO.
DIRECT BURY,
6 STRAND SMFO.
DIRECT BURY,
6 STRAND SMFO.
DIRECT BURY,
6 STRAND SMFO.
6. 3/4" PLYWOOD BOARD FOR MOUNTING OF VOICE AND DATA EQUIPMENT AND
DEVICES. NO PAINT OR ANY SEALER SHALL BE APPLIED THE THE PLYWOOD
BOARD.
CONTROL TOWER
OFFICE
OPS/STORAGE
FIRST FLOOR
3/4" CONDUIT
6 STRAND SMFO.
1. QUANTITY OF COMMUNICATION HANDHOLES FOR DISPLAY PURPOSE ONLY. SEE SHEET ES121.
US Army Corps of Engineers ® Omaha District
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
TN601
TE
LE
C O
M M
U N
IC
A T
IO
N
S R
IS
E R
D
IA
G R
AM
AU
TO
M
AT
ED
IN
FA
N
TR
Y
PL
AT
O O
N B
A T
TL
E C
O U
R
SE
O M
A H A
D
IS
T R
IC
T O
M
AH
A, N
EB
R
AS
KA
B.
W
LA
SC
H
IN
B.
W
LA
SC
H
IN
S.
O
TT
S.
O
TT
/2
7/
W
F-
-R
-0
F2
-1 5-
FO
R
T C
AR
SO
N , C
O
LO
R
AD
O
PN
7 2
(F
Y 1 7)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
G
EN
ER
AL
R
EV
IS
IO
N S
-0
2-
AM
G
EN
ER
AL
R
EV
IS
IO
N S
-0
9-
| FCBAES101 |
| ES101 |
| References |
| FCBAG-BSD 2.dgn |
| FC Elec Layout.dgn |
| Ref-1, FCBAC-RASTER.dgn |
| FCBAES301 |
| FCBAES404 |
| FCBAES404A |
| FCBAE-101CT |
| FCBAE-102CT |
| FCBAE-101OS |
| FCBAEL501 |
| FCBAEL501A |
| FCBAEL502 |
| FCBAEP602 |
| FCBAEP602A |
| FCBATN502 |
| FCBATN601 |
File details come from the government source that posted it. Updated .