Gavins_Pt_drawing_01_06_2017.pdf
PDF 3 MB Posted
- Attached to
- Gavins Point Excitation System Replacement Federal contract opportunity
- Solicitation number
- W9128F-16-T-0044
About this file
Amendment #7 Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment__10_W9128F-16-T-0044.pdf | ||
| Amendment__9_W9128F-16-T-0044.pdf | ||
| Contractor_Questions-Amendment25Oct2016.pdf | ||
| Additonal_Specs.pdf | ||
| Past_Performance_Questionnaire.pdf | ||
| Gavins_Pt_Ref_01_06_2017.pdf | ||
| Amendment__7_Gavins_Point.pdf | ||
| Amendment__6_W9128F-16-T-0044.pdf | ||
| Amendment__5_W9128F-16-T-0044.pdf | ||
| Amendment__4_W9128F-16-T-0044.pdf | ||
| Amendment__3_W9128F-16-T-0044.pdf | ||
| Amendment__2_W9128F-16-T-0044.pdf | ||
| Amendment__1_W9128F-16-T-0044.pdf | ||
| Gavins_Point_reference.pdf | ||
| Gavins_Point_Exciters_Dwgs.pdf | ||
| Gavins_Point_Exciters_Dwgs.7z | 7Z file | |
| 1442_and_clauses.pdf | ||
| Gavins_Point_Exciters_Specs.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NN
X
X
X
X
X
X
X
X
X
XX
X
CAMP LOOP 1
REST ROOM
REST ROOM
CAMP LOOP 2
HOUSE
CHANGE
WELL
PICNIC AREA
WELL
FACILITY
FISH CLEANING
TRAINING DIKE RD
TOE RD.
CREST RD.
SPILLWAY
POWER PLANT
RADIO TOWER
BOUNDARY
PROJECT
MAINT. YARD
STOR. BLDG.
SHOP &
DISPOSAL STA.
SANITARY
LAGOON
AREA 2
PICNIC
ROOM
REST
N
G P
P X .X
X X
G -0
X X
X .D
G N .d g n
S T
E V
E N R
M
IL
E S P .E
A N
S I
D
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T G
H
D C J L
R
R
R E
Y N
O L
D S
P R
O J E
C T L
O C
A T
IO
N
G-001
Omaha District of Engineers
US Army Corps
G A
V
IN
S P
O
IN
T D
A M
LEWIS & CLARK LAKE
NEBRASKA
SOUTH DAKOTA
POINT DAM
GAVINS
SPRINGFIELD
YANKTON
CROFTON
BEAVER
CR.
W E I
G A
N D
C R
C H
A R
L I
E
S N
A T
C H
S A
N D
C R
C R
C R
TABOR
B A
Z I
L E
C R
F L
O W
M
IS
S O
U R I R
IV
E R
NEBRASKA
LEWIS & CLARK LAKE
F L
O W
AREA 1
PICNIC
AREA 3
PICNIC
CENTER
VISITOR
T A
IL
W A
T E
R A
R E
A SWIMMING AREA
RAMP
RAMP
RAMP
S W
Y D
KNOX CO.
CEDAR CO.
AREAPUBLI
C
USE
SOUTH
SHORE
DAKOTA
SOUTH
EXCITATION SYSTEM REPLACEMENT
GAVINS POINT POWERHOUSE
A N
D V
IC
IN
IT
Y M
A P
P O
W E
R H
O U
S E
E X
C
IT
E R R
E P
L A
C E
M E
N
M
IS
S O
U R I
R
IV
E R
MISSOURI RIVER, NEBRASKA
G P
P -1 .0
-0 /1
NTS
PROJECT LOCATION
NTS
VICINITY MAP
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D R
A W
IN
G N
U M
B E
R of Engineers
US Army Corps
P L
O T D
A T
E
54321
D
C
B
A
/6 /2
BORDER VERSION UPDATE [09-2012]
G-001SHEET NAME:g2hdcddw Deborah WilliamsBY USERNAME:ANSI DDRAWING PLOT SIZE: DATE AND TIME PLOTTED: 1/6/2017 1:02:29 PM
D R
A W
N B
Y
C H
E C
K E
D B
Y
OMAHA DISTRICT
G P
P X .X
X X
G -0
X X
X .D
G N .d
E V
E N R
M
IL
E S P .E
A N
S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T G
H
D C J L
R
R
R E
Y N
O L
D
G-002
INDEX TO DRAWINGS
TITLE
GENERAL
NO.
SHEET
TITLE
REFERENCE DRAWINGS
FILE NUMBER
ELECTRICAL REMOVAL
ELECTRICAL INSTALL
IN
D
E X O
F D
R A
W
IN
G S
G A
V
IN
S P
O
IN
T D
A M
REFERENCE DRAWINGS
FILE NUMBER
P O
W E
R H
O U
S E
E X
C
IT
E R R
E P
L A
C E
M E
S O
U R I
R
IV
E R
DRAWING NUMBER
G P
P -1 .0
-0 /2
G-002
G-001
ED101
GPP-1.06 G-002.DGN
GPP-1.06 G-001.DGN
GPP-1.06_ED101XXX.DGN
FILE NAME
GPP-1.06-0/2
GPP-1.06-0/1
GPP-1.06-6-1D11/1
INDEX OF DRAWINGS
PROJECT LOCATION AND VICINITY MAP
EXISTING EXCITATION EQUIPMENT ARRANGEMENT SERVICE BAY EL 1179.5 - REMOVAL
E-903
E-902
E-901
E-601
E-401
E-101
GPP-1.06_E-903XXX.DGN
GPP-1.06_E-902XXX.DGN
GPP-1.06_E-901XXX.DGN
GPP-1.06_E-601XXX.DGN
GPP-1.06_E-401XXX.DGN
GPP-1.06_E-101XXX.DGN
GPP-1.06-6-1D11/7
GPP-1.06-6-1D11/6
GPP-1.06-6-1D11/5
GPP-1.06-6-1D11/4
GPP-1.06-6-1D11/3
GPP-1.06-6-1D11/2
EXISTING FIELD LEAD ROUTING - SHT 2
EXISTING FIELD LEAD ROUTING - SHT 1
UNITS 1, 2 AND 3 EXISTING EQUIPMENT ARRANGEMENT - INSTALL
EXCITATION SYSTEM EXTERNAL CONNECTIONS - INSTALL
GENERATOR SWITCHBOARD ARRANGEMENT ALL UNITS
NEW EXCITATION EQUIPMENT ARRANGEMENT - INSTALL
MG8-82E2.1
MG72-83E118.3
MG72-83E137.2
MG72-83E138.2
MG72-83E139.5
MG72-83E140.6
MG72-83E141.3
MG72-83E143.4
MG72-83E144.6
MG72-83E145.3
MG72-83E146.4
MG72-83E147.2
MG72-83E148.7
MG72-83E149.6
MG72-83E150.8
MG72-83E151.7
MG72-83E152.8
MG72-83E153.7
MG72-83E154.10
MG72-83E155.7
MG-OPN-83E232A
MG-OPN-83E300.7
MG-OPN-83E301.16
MG-OPN-83E2101.3
MG-OPN-83E304.10
MG-OPN-83E307
MG-OPN-83E320A
MG-OPN-83E320B
MG-OPN-83E320E
MG-OPN-83E320F
MG-OPN-83E320G
MG-OPN-83E325A
MG-OPN-83E325B
MG-OPN-83E325C
MG-OPN-83E325D
MG-OPN-83E325E
MG-OPN-83E325F
MG-OPN-83E325G
MG-OPN-83E311.12
MG-OPN-83E311A.6
MG-OPN-83E312.10
MG-OPN-83E312A.5
MG-OPN-83E313.8
MG-OPN-83E313A.5
MG-OPN-83E410.5
POWERHOUSE TRANSVERSE SECTION
ARRANGEMENT OF SWITCHGEAR GENERATOR MAIN LEADS AND CONTROL ROOM
CABLE TRAY ARRANGEMENT SHEET 1
CABLE TRAY ARRANGEMENT SHEET 2
CABLE TRAY ARRANGEMENT SHEET 3
CABLE TRAY ARRANGEMENT SHEET 4
CABLE TRAY ARRANGEMENT SHEET 5
CONDUIT & GROUNDING, GENERATOR FLOOR, EL. 1195.0 SHEET 1
CONDUIT & GROUNDING, GENERATOR FLOOR, EL. 1195.0 SHEET 2
CONDUIT & GROUNDING, GENERATOR FLOOR, EL. 1195.0 SHEET 3
CONDUIT & GROUNDING, GENERATOR FLOOR, EL. 1195.0 SHEET 4
CONDUIT & GROUNDING, CONTROL ROOM, EL. 1195.0
CONDUIT & GROUNDING, ERECTION BAY, EL. 1195.0 SHEET 1
CONDUIT & GROUNDING, ERECTION BAY, EL. 1195.0 SHEET 2
CONDUIT AND GROUNDING TURBINE FLOOR UNIT1 EL.1179.5 SHEET 1
CONDUIT AND GROUNDING TURBINE FLOOR UNIT 1 EL.1179.5 SHEET 2
CONDUIT AND GROUNDING TURBINE FLOOR UNIT 2 EL.1179.5 SHEET 1
CONDUIT AND GROUNDING TURBINE FLOOR UNIT 2 EL.1179.5 SHEET 2
CONDUIT AND GROUNDING TURBINE FLOOR UNIT 3, EL.1179.5 SHEET 1
CONDUIT AND GROUNDING TURBINE FLOOR UNIT 3 EL.1179.5 SHEET 2
POWER HOUSE LIGHTING PANEL SCHEDULES AND RISER DIAGRAM
DEVICE SCHEDULE
SINGLE LINE DIAGRAM SHEET 1
125V DC & 115V AC SINGLE LINE DIAGRAMS
THREE LINE DIAGRAM SHEET 1
STATIC EXCITATION SYSTEM THREE LINE DIAGRAM
UNIT 1 - EXCITATION SYSTEM AC/DC MAIN POWER CIRCUITS
UNIT 1 - EXCITATION SYSTEM DC POWER CIRCUITS
UNIT 1 - EXCITATION SYSTEM PROTECTIVE RELAYS
UNIT 1 - EXCITATION SYSTEM REDUNDANT POWER SUPPLIES
UNIT 1 - EXCITATION SYSTEM REGULATOR INPUT & OUTPUT SIGNALS
UNIT 1 - EXCITATION SYSTEM DC CONTROL SCHEMATIC SHEET 1
UNIT 1 - EXCITATION SYSTEM DC CONTROL SCHEMATIC SHEET 2
UNIT 1 - EXCITATION SYSTEM DC CONTROL SCHEMATIC SHEET 3
UNIT 1 - EXCITATION SYSTEM DC CONTROL SCHEMATIC SHEET 4
UNIT 1 - EXCITATION SYSTEM DC CONTROL SCHEMATIC SHEET 5
UNIT 1 - EXCITATION SYSTEM DC CONTROL SCHEMATIC SHEET 6
UNIT 1 - EXCITATION SYSTEM CUSTOMER TERMINAL BLOCKS WIRING
UNIT 1 CONTROL DIAGRAM
UNIT 1 CONTROL DIAGRAMS SHEET 2
UNIT 2 CONTROL DIAGRAM
UNIT 2 CONTROL DIAGRAMS SHEET 2
UNIT 3 CONTROL DIAGRAM
UNIT 3 CONTROL DIAGRAM SHEET 2
ANNUNCIATOR SCHEDULE SHEET 1
MG-OPN-83E902.5
MG-OPN-83E903.1
MG-OPN-83E904.10
MG-OPN-83E905.3
MG-OPN-83E906.5
MG-OPN-83E921.10
MG-OPN-83E923.11
MG-OPN-83E924.11
MG-OPN-83E928.10
MG-OPN-83E929.11
MG-OPN-83E933.10
MG-OPN-83E934.9
MG-OPN-83E936.9
MG-OPN-83E987.8
MG-OPN-83E115C.1
MG-OPN-83C5001
MG-OPN-83C5008
MG-OPN-83C5010
MG-OPN-83C5012
MG-OPN-83C5027
MG-OPN-83C5028
MG-OPN-83C5029
MG-OPN-83C5030
MG-OPN-83C5031
MG-OPN-83C5032
MG-OPN-83C5033
MG-OPN-83C5034
MG-OPN-83C5035
MG-OPN-83C5044
MG-OPN-83C5053
MG-OPN-83C5062
MG-OPN-83C5095
MG-OPN-83C5100
MG-OPN-83C5103
S4-210-MEC-401 SHEET 6
S4-210-MEC-302
S4-210-MEC-303
S4-210-MEC-401 SHEET 1
S4-210-MEC-401 SHEET 2
S4-210-DDC-140 SHEET 1
S4-210-DDC-140 SHEET 2
S4-210-SCC-401 SHEET 3
S4-210-SCC-401 SHEET 26
E-222-K
INSTRUMENT BOARD ASSEMBLY
INSTRUMENT BOARD NAMEPLATE SCHEDULE AND BILL OF MATERIALS
ACTUATOR AND INSTRUMENT BOARD ANNUNCIATION
INSTRUMENT BOARD SWITCH DEVELOPMENT SHEET 1
RELAY BOARD ASSEMBLY
INSTRUMENT BOARD WIRING PANEL 1IB
INSTRUMENT BOARD WIRING PANEL 2IB
RELAY BOARD WIRING PANEL 2RB
INSTRUMENT BOARD WIRING PANEL 4IB
RELAY BOARD WIRING PANEL 4RB
INSTRUMENT BOARD WIRING PANEL 6IB
RELAY BOARD WIRING PANEL 6RB
INSTRUMENT BOARD WIRING PANEL 7IB
125V DC BOARD WIRING PANELS 5 & 6
TERMINAL DIAGRAM GENERATING UNIT 3
CONDUIT & CABLE SCHEDULE INDEX & LEGEND
CONDUIT & CABLE SCHEDULE
CONDUIT & CABLE SCHEDULE
CONDUIT & CABLE SCHEDULE
CONDUIT & CABLE SCHEDULE
CONDUIT & CABLE SCHEDULE
CONDUIT & CABLE SCHEDULE
CONDUIT & CABLE SCHEDULE
CONDUIT & CABLE SCHEDULE
CONDUIT & CABLE SCHEDULE
CONDUIT & CABLE SCHEDULE
CONDUIT & CABLE SCHEDULE
CONDUIT & CABLE SCHEDULE
CONDUIT & CABLE SCHEDULE
CONDUIT & CABLE SCHEDULE
CONDUIT & CABLE SCHEDULE
CONDUIT & CABLE SCHEDULE
CONDUIT & CABLE SCHEDULE
CONDUIT & CABLE SCHEDULE
BUS ARRANGEMENT
TOP COVER & CUBICLE - REGULATOR & AC BREAKER SECTIONS
REGULATOR / CONTROL SECTION ARRANGEMENT
REGULATOR / CONTROL SECTION ARRANGEMENT
REGULATOR / CONTROL SECTION DOOR DETAIL
SCHEMATIC DIAGRAM - STANDARD DRAWING PRACTICES
SCHEMATIC DIAGRAM - STANDARD DRAWING PRACTICES
SCHEMATIC DIAGRAM - GENERATOR LOCKOUT CONTROL
REAR VIEW OF CUBICLES 4, 5 & 6 OF 13.8KV SWGR. 1 & 2 LOC OF PWR EQUIP & BUS CONNECTION
TOP COVER & CUBICLE - BRIDGE SECTIONS 1 & 2
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D R
A W
IN
G N
U M
B E
R of Engineers
US Army Corps
P L
O T D
A T
E
54321
D
C
B
A
/6 /2
BORDER VERSION UPDATE [09-2012]
G-002SHEET NAME:g2hdcddw Deborah WilliamsBY USERNAME:ANSI DDRAWING PLOT SIZE: DATE AND TIME PLOTTED: 1/6/2017 1:02:36 PM
D R
A W
N B
Y
C H
E C
K E
D B
Y
VOLUME 1
NOTES:
REFERENCE DRAWINGS:
PPT PPT PPT
UNIT 1 UNIT 2 UNIT 3
5' 0 5' 10'
"= 1'-0"8
1SCALE:
UNIT 1 EXCITER FOOTPRINT
UNIT 2 EXCITER FOOTPRINT UNIT 3 EXCITER FOOTPRINT
F L
O W
EXISTING SWITCHGEAR
DRAWINGS, (TYP.)
SEE REFERENCE
EXISTING CABLE TRAYEXISTING SWITCHGEAR
SEE NOTE 2
EXISTING CABLE TRAYS
UNIT 3UNIT 2UNIT 1
TRANSFORMER, (TYP.)
POWER POTENTIAL
1 AND 3
SEE NOTES
1 AND 3
SEE NOTES
G P
P X .X
X X E
D
X X
X .D
G N .d
E V
E N R
M
IL
E S P .E
A N
S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T G
H
D C J L
R
R
R E
Y N
O L
D S
ED101
R E
M O
V A
L
G A
V
IN
S P
O
IN
T D
A M
E X
C
IT
E R R
E P
L A
C E
M E
S O
U R I
R
IV
E R
P O
W E
R H
O U
S E
E X
IS
T
IN
G E
X C
IT
A T
IO
N E
Q U
IP
M E
N T
A R
R A
N G
E M
E N
T S
E R
V
IC
E B
A Y E
L
.5
G P
P -1 .0
-6 -1
D /1
5. SEE NOTE 1 ON SHEET E-101.
EQUIPMENT TO BE REMOVED.
4. BOLD LINES INDICATE FOOTPRINT OF EXISTING
CUBICLES AND ALL WIRE AND CABLE CONNECTED.
3. CONTRACTOR SHALL REMOVE EXISTING EXCITATION
2. FOR CLARITY, NOT ALL COMPONENTS ARE SHOWN.
AND CONDUIT ACCESS FOR EXCITATION WIRING.
1. CONTRACTOR CAN REUSE EXISTING CABLE TRAY
CABLE TRAY ARRANGEMENT SHEET 5MG72-83E141.3
CABLE TRAY ARRANGEMENT SHEET 4MG72-83E140.6
CABLE TRAY ARRANGEMENT SHEET 3MG72-83E139.5
CABLE TRAY ARRANGEMENT SHEET 2MG72-83E138.2
CABLE TRAY ARRANGEMENT SHEET 1MG72-83E137.2
KEY PLAN
SERVICE BAY EL 1179.5
O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D R
A W
IN
G N
U M
B E
R of Engineers
US Army Corps
P L
O T D
A T
E
54321
D
C
B
A
/6 /2
BORDER VERSION UPDATE [09-2012]
ED101SHEET NAME:g2hdcddw Deborah WilliamsBY USERNAME:ANSI DDRAWING PLOT SIZE: DATE AND TIME PLOTTED: 1/6/2017 1:02:44 PM
D R
A W
N B
Y
C H
E C
K E
D B
Y
UNIT 1 UNIT 2 UNIT 3
F L
O W
5' 0 5' 10'
"= 1'-0"8
1SCALE:
EXISTING SWITCHGEAR
SEE REFERENCE DRAWINGS, (TYP.)
EXISTING CABLE TRAY EXISTING SWITCHGEAR
REFERENCE DRAWINGS, (TYP.)
SEE NOTE 2 AND
EXISTING CABLE TRAYS
SEE NOTES 1 AND 3
UNIT 3 EXCITER CABINET FOOTPRINT
FOR EXCITER/PPT (TYP.)
17'-11" X 4'6" MAXIMUM FOOTPRINT
FOOTPRINT. SEE NOTES 1 AND 3
UNIT 1 EXCITER CABINET
FOOTPRINT.SEE NOTES 1 AND 3
UNIT 2 EXCITER CABINET
UNIT 3UNIT 2UNIT 1
REFERENCE DRAWINGS:
NOTES:
1. SEE REFERENCE DRAWING MG72-83E118.3 FOR
LOCATION OF 9' X 9' HATCH NEXT TO UNIT 2 FOR
ACCESS TO THIS ELEVATION.
2. FOR CLARITY, NOT ALL COMPONENTS ARE SHOWN.
3. CONTRACTOR SHALL INSTALL THE PPT AND EXCITATION
CUBICLE WITHIN THE DIMENSIONS OF THE FOOTPRINT.
THE CONTRACTOR CAN UTILIZE THE EXISTING CONDUIT
ACCESS TO THE CABLE TRAY.
4. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN OF THE
EXCITATION SYSTEM.
PROJECT PERSONNEL FOR ASSISTANCE.
BY THE AWNING IN FRONT OF THE POWERHOUSE. CONTACT
7. SERVICE TRAILER LOCATION IS EITHER BY THE SWITCHYARD OR
SERVICE BAY SHOWN.
6. THE CONTRACTOR CAN ESTABLISH A WORK AREA IN THE
5. BOLD LINES INDICATE FOOTPRINT OF EXISTING EQUIPMENT.
SEE NOTE 1
G P
P X .X
X X E -1
X X
X .D
G N .d
E V
E N R
M
IL
E S P .E
A N
S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T G
H
D C J L
R
R
R E
Y N
O L
D S
E-101
IN
S
T A
L L
G A
V
IN
S P
O
IN
T D
A M
E X
C
IT
E R R
E P
L A
C E
M E
S O
U R I
R
IV
E R
P O
W E
R H
O U
S E
N E
W E
X C
IT
A T
IO
N E
Q U
IP
M E
N T
A R
R A
N G
E M
E N
T G
P P -1 .0
-6 -1
D /1
CABLE TRAY ARRANGEMENT SHEET 5MG72-83E141.3
CABLE TRAY ARRANGEMENT SHEET 4MG72-83E140.6
CABLE TRAY ARRANGEMENT SHEET 3MG72-83E139.5
CABLE TRAY ARRANGEMENT SHEET 2MG72-83E138.2
CABLE TRAY ARRANGEMENT SHEET 1MG72-83E137.2
KEY PLAN
SERVICE BAY EL. 1179.5
1 TOP VIEW OF ACCESS HATCH
2 LOOKING UP FROM EL 1179.5
BOTTOM VIEW OF ACCESS HATCH
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D R
A W
IN
G N
U M
B E
R of Engineers
US Army Corps
P L
O T D
A T
E
54321
D
C
B
A
/6 /2
BORDER VERSION UPDATE [09-2012]
E-101SHEET NAME:g2hdcddw Deborah WilliamsBY USERNAME:ANSI DDRAWING PLOT SIZE: DATE AND TIME PLOTTED: 1/6/2017 1:02:52 PM
D R
A W
N B
Y
C H
E C
K E
D B
Y
N7
A
V
W
A
SI
GL
VAR
SLI
N20
N21
N7
A
V
W
A
PF
SI
GL
VAR
SLI
N20
N21
EXISTING LAYOUT-REMOVAL NEW LAYOUT-INSTALL
REMOVE FIELD AMMETER
REMOVE FIELD VOLTMETER
A V
V
A V
V PF
INSTALL NEW AMMETER AND VOLTMETER
NOTES:
AND MG-OPN83E903.5.
1. SEE REFERENCE DRAWINGS MG-OPN-83E902.5
OF PARAGRAPH 3.7.1.4
PER APPLICABLE REQUIREMENTS
FILL HOLE IN SWITCHBOARD
(NULL) METER
REMOVE BALANCE
REMOVE VOLTAGE ADJUST SWITCH
REGULATOR CONTROL SWITCH
REMOVE VOLTAGE
REGULATOR CONTROL SWITCH
INSTALL NEW VOLTAGE
VOLTAGE ADJUST SWITCH
INSTALL NEW
G P
P X .X
X X E -4
X X
X .D
G N .d
E V
E N R
M
IL
E S P .E
A N
S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T G
H
D C J L
R
R
R E
Y N
O L
D S
E-401
G A
V
IN
S P
O
IN
T D
A M
E X
C
IT
E R R
E P
L A
C E
M E
S O
U R I
R
IV
E R
P O
W E
R H
O U
S E
G P
P -1 .0
-6 -1
D /3
G E
N E
R A
T O
R S
W
IT
C H
B O
A R
D
A R
R A
N G
E M
E N
T A
L L U
N
IT
NTS
(TYPICAL FOR ALL UNITS)
GENERATOR SWITCHBOARD
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D R
A W
IN
G N
U M
B E
R of Engineers
US Army Corps
P L
O T D
A T
E
54321
D
C
B
A
/6 /2
BORDER VERSION UPDATE [09-2012]
E-401SHEET NAME:g2hdcddw Deborah WilliamsBY USERNAME:ANSI DDRAWING PLOT SIZE: DATE AND TIME PLOTTED: 1/6/2017 1:03:00 PM
D R
A W
N B
Y
C H
E C
K E
D B
Y
POSITIONS
MANUALREG
X
X
X
X
CONTACTS
MANUAL
OFF REG
OFF
6 X
X
POSITIONS
RAISE
X
X
X
X
CONTACTS
LOWER
NORMAL
LOWER RAISE
TO NORMAL
SPRING RETURN
OVAL HANDLE
MAINTAINED CONTACTS
NOTES:
LEGEND:
EXCITATION CUBICLE EXTERNAL CONNECTIONS
NBFA
CLOSE
CONTACTS
X
X
X
X
CLOSETRIP
POSITIONS
NORMAL
TRIP
1XE EXCITER BREAKER
TO NORMAL
SPRING RETURN
PHASE UNBALANCE
PPT TEMP TRIP
RAISE
FAULT OVER-CURRENT
EMERG. SHUTDOWN
BREAKER
TRIP EXC
LOWEROFF AUTO MANUALON
EXCITATIONON LINE
UNIT100 mV SHUNT
CONTROL
REGULATOR
POWER
CONVENIENCE
SENSING
CURRENTREG. PT's FLASHING
FIELD
STATUS
REGULATOR
ADJUST
VOLTAGE
CONTROL
EXCITER BREAKER
PROTECTION
TRANSFORMER
52E
B U
S
G E
N E
R A
T O
R
PPT
OUTPUTS TO DACS
HARDWIRED ANALOG
120 V
14,400/
2000/5A
120 VAC 125 VDC 125 VDC
S_
N B
F
P B
F
N F
F
P F
F
(S_) (S_)
R E
G
M A
N U
A L
L
IM
IT
U P
P E
R
(SC)
(S_) (S_) (S_)
(SC)
V O
L T
A G
E
R A
T E
D
L
IM
IT
L O
W E
R
(SC)
R W
R
R
A
A
G
G R
(S_) (S_)
G
TO 11G
P C
43LC CONTROL TRANSFER
CENTRAL LOCAL
OVAL HANDLE
MAINTAINED CONTACTS
POSITIONS
CENTRAL LOCALCONTACTS
4 X
X
X
X
HARDWIRED DIGITAL OUTPUTS TO PPCS
VOLTAGE
FIELD
CURRENT
FIELD
CLOSED
EXC. BKR.
OPEN
EXC. BKR.
UNBALANCE
PHASE
TEMP.
PPT OVER
AUTO
REG IN
IN AUTO
REG NOT
OVERTEMP
BRIDGE
SERVICE
PSS IN
OVERCURRENT
FAULT
EXC. TRIP
HIGH OVER
EXC. TRIP
OVER
EXC. LIMIT
UNDER
LIMIT
MAX. EXC.
TROUBLE
EXCITER
TRIP
EXCITER
MANUAL
TRIP TO
REGULATOR
HARDWIRED DIGITAL OUTPUTS TO PPCS
ETHERNET SYSTEM
CONTROL
TO PLANT
RS 485
RS-232 VOLTMETER
GEN. FIELD
(S_)
AMMETER
FIELD
GENERATOR
SX
ALARM
PPT
TRIP
PPT
(S_)
FV FA
F
PBFA
52a
MAN
43RV
AND ABOVE
95% SPEED
CLOSED AT
13X
(S_)
(A)
(S_)
REG
43RV
(S_)
OFF
43RV
(S_)
REG
43RV
(S_)
MAN
43RV
86C 87GX
1XE
LOCAL
LOCAL
1MVL
(S )
1MVR
(S )
1MVL
(SC)
1MVR
(SC)
60L 60R
CENTRAL
L
PPCS
R
PPCS
FOR EXISTING EXCITATION SYSTEM UNTIONALITY.
4. SEE REFERENCE DRAWINGS MB-OPN83E307,
3. RETAIN 64F RELAY.
2. INSERT PANEL NUMBER FOR UNDERLINE, (S_).
1. ITEMS SHOWN IN BOLD ARE TO BE INSTALLED.
SEE NOTE 3
SEE NOTE 2, (TYP.)
LEADS
CALIBRATED
64F
X
(S )
CE1
DACS
87GX
86GC
52a
43RV
43LC
13X
1XE
1MV
(A)
GENERATOR FIELD GROUND
VOLTAGE BALANCE
AUXILIARY
LOCATED ON GENERATOR SWITCHBOARD
125 VDC PANEL
DATA ACQUISITION AND CONTROL SYSTEM
DIFFERENTIAL RELAY
EMERGENCY STOP LOCKOUT RELAY
AC CIRCUIT BREAKER AUX CONTACT
VOLT. REG. TRANSFER (MANUAL/REG)
(LOCAL/CENTRAL)
CONTROL TRANSFER SWITCH
SYNCHRONOUS SPEED SWITCH
EXCITER BREAKER CONTROL SWITCH
VOLTAGE ADJUST CONTROL SWITCH
LOCATED ON ACTUATOR CABINET
43RV VOLT. REG. TRANSFER
1MV VOLTAGE ADJUST
JA
JB
JC
G P
P X .X
X X E -6
X X
X .D
G N .d
E V
E N R
M
IL
E S P .E
A N
S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T G
H
D C J L
R
R
R E
Y N
O L
D S
E-601
E X
C
IT
A T
IO
N S
Y S
T E
M
G A
V
IN
S P
O
IN
T D
A M
E X
C
IT
E R R
E P
L A
C E
M E
S O
U R I
R
IV
E R
P O
W E
R H
O U
S E
E X
T E
R N
A L C
O N
N E
C T
IO
N S
G P
P -1 .0
-6 -1
D /4
O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D R
A W
IN
G N
U M
B E
R of Engineers
US Army Corps
P L
O T D
A T
E
54321
D
C
B
A
/6 /2
BORDER VERSION UPDATE [09-2012]
E-601SHEET NAME:g2hdcddw Deborah WilliamsBY USERNAME:ANSI DDRAWING PLOT SIZE: DATE AND TIME PLOTTED: 1/6/2017 1:03:07 PM
D R
A W
N B
Y
C H
E C
K E
D B
Y
PHOTO 1 PHOTO 2 PHOTO 3
PHOTO 4 PHOTO 5
NOTES:
SYSTEM NO.3 IS ON THE OTHER SIDE OF THE DOOR
EXISTING EXCITATION SYSTEM NO. 1 AND 2, EXCITATION
CABLE TRAY. SEE CABLE TRAY REFERENCE DRAWINGS
ACCESS FROM EXCITATION CUBICLE NO. 2 TO EXISTING
SEE PHOTO 2
TYPICAL CABLE ENTRY INTO CABLE TRAY VIA CONDUIT
AND CONTINUATION FROM PHOTO 4
VIEW OF CONDUITS ABOVE POWER POTENTIAL TRANSFORMER (PPT)
TRAYS. SEE PHOTO 5 FOR CONTINUATION
CONDUITS ABOVE EXCITATION CUBICLE TO EXISTING CABLE
EXCITATION SYSTEM.
2. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN OF THE
FOR ROUTING OF CONDUCTORS.
1. CONTRACTOR MAY USE EXISTING CONDUIT AND CABLE TRAY
G P
P X .X
X X E -9
X X
X .D
G N .d
E V
E N R
M
IL
E S P .E
A N
S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T G
H
D C J L
R
R
R E
Y N
O L
D S
E X
IS
T
IN
G E
Q U
IP
M E
N T A
R R
A N
G E
M E
N T
E-901
G A
V
IN
S P
O
IN
T D
A M
E X
C
IT
E R R
E P
L A
C E
M E
S O
U R I
R
IV
E R
P O
W E
R H
O U
S E
U N
IT
S A
N D
G P
P -1 .0
-6 -1
D /5
O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D R
A W
IN
G N
U M
B E
R of Engineers
US Army Corps
P L
O T D
A T
E
54321
D
C
B
A
/6 /2
BORDER VERSION UPDATE [09-2012]
E-901SHEET NAME:g2hdcddw Deborah WilliamsBY USERNAME:ANSI DDRAWING PLOT SIZE: DATE AND TIME PLOTTED: 1/6/2017 1:03:14 PM
D R
A W
N B
Y
C H
E C
K E
D B
Y
PHOTO 1 PHOTO 2 PHOTO 3
PHOTO 4 PHOTO 5
NOTES:
PHOTO 6
PHOTO 7 PHOTO 8
EXCITATION CUBICLE FOR FIELD LEADS
TRIPLE PARALLELED CABLES INSIDE
PARALLELED CABLES ROUTED IN CONDUIT
CONTINUATION FROM PHOTO 1. TRIPLE
ARE HUNG FROM THE CEILING.
ROUTING CONTINUES. CONDUITS
TOWARD GALLERY WALL.
FIELD LEAD CONDUITS TURN
CABLE TRAY AND TO GALLERY WALL
FIELD LEAD CONDUITS ARE ROUTED ABOVE
GALLERY WALL TOWARD GENERATOR BARREL
FIELD LEAD CONDUITS ARE ROUTED THROUGH
DOWN GENERATOR BARREL
FIELD LEAD CONDUITS ROUTED SEE PHOTO 9, DRAWING E-903
FIELD LEAD CONDUITS ENTER GENERATOR BARREL
EXCITATION SYSTEM.
2. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN OF THE
ROUTING OF CONDUCTORS.
1. CONTRACTOR MAY USE EXISTING PATH AND/OR CONDUIT FOR
E V
E N R
M
IL
E S P .E
A N
S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T G
H
D C J L
R
R
R E
Y N
O L
D S
E-902
G A
V
IN
S P
O
IN
T D
A M
E X
C
IT
E R R
E P
L A
C E
M E
S O
U R I
R
IV
E R
P O
W E
R H
O U
S E
G P
P -1 .0
-6 -1
D /5
G P
P .0
E -9
X X
X .D
G N .d g n
R O
U T
IN
G S
H
.1
IE
L D L
E A
D
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D R
A W
IN
G N
U M
B E
R of Engineers
US Army Corps
P L
O T D
A T
E
54321
D
C
B
A
/6 /2
BORDER VERSION UPDATE [09-2012]
E-902SHEET NAME:g2hdcddw Deborah WilliamsBY USERNAME:ANSI DDRAWING PLOT SIZE: DATE AND TIME PLOTTED: 1/6/2017 1:03:28 PM
D R
A W
N B
Y
C H
E C
K E
D B
Y
PHOTO 9 PHOTO 10 PHOTO 11
PHOTO 13 PHOTO 14
NOTES:
PHOTO 15
PHOTO 16
PHOTO 12
JUNCTION BOX. SEE PHOTO 8, SHT E-902
FIELD LEADS ENTERING GENERATOR BARREL TO INTERNAL VIEW OF FIELD LEAD JUNCTION BOX
UP INSIDE OF GENERATOR BARRELL
FIELD LEADS LEAVING JUNCTION BOX
WALKWAY SHOWN. SEE NOTE 3
FIELD LEADS ARE ROUTED BELOW
SEE NOTE 3 & PHOTO 12
FIELD CONDUCTORS UNDER WALKWAY
TO COLLECTOR RINGS
FIELD LEAD CONNECTION
COLLECTOR RINGS ARE LOCATED
FIELD LEADS ENTERING HOUSING WHERE
SEE NOTE 4
TYPICAL FIELD LEAD ROUTING
PHOTO 17
SLIP RINGS AND BRUSH HOLDERS
4. WHEREVER POSSIBLE, PROTECT FIELD LEADS WITH CONDUIT.
3. ROUTE CONDUCTORS UNDER WALKWAY IN CONDUIT.
EXCITATION SYSTEM.
2. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN OF THE
FOR ROUTING OF CONDUCTORS.
1. CONTRACTOR MAY USE EXISTING CONDUIT AND CABLE TRAY
E V
E N R
M
IL
E S P .E
A N
S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T G
H
D C J L
R
R
R E
Y N
O L
D S
E-903
G A
V
IN
S P
O
IN
T D
A M
E X
C
IT
E R R
E P
L A
C E
M E
S O
U R I
R
IV
E R
P O
W E
R H
O U
S E
G P
P -1 .0
-6 -1
D /5
G P
P .0
E -9
X X
X .D
G N .d g n
R O
U T
IN
G S
H
.2
IE
L D L
E A
D
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
D A
T E
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D R
A W
IN
G N
U M
B E
R of Engineers
US Army Corps
P L
O T D
A T
E
54321
D
C
B
A
/6 /2
BORDER VERSION UPDATE [09-2012]
E-903SHEET NAME:g2hdcddw Deborah WilliamsBY USERNAME:ANSI DDRAWING PLOT SIZE: DATE AND TIME PLOTTED: 1/6/2017 1:03:38 PM
D R
A W
N B
Y
C H
E C
K E
D B
Y
File details come from the government source that posted it. Updated .