Changes to the Specifications and Drawings
View the file
Other files
| File | Type | Posted |
|---|---|---|
| B3_IFB_(AM04)_18B0035.pdf | ||
| B3_IFB_(AM03)_18B0035.pdf | ||
| B56_Site_Visit_Sign_In_Sheet.pdf | ||
| B3_IFB_(AM_01)_18B0035.pdf | ||
| B3_IFB_B56_18B0035.pdf | ||
| B3_IFB_(Drawings)_B56_18B0035.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The Solicitation for Renovation Building 56, Fort Sam Houston, San Antonio, Texas is amended as follows.
See SF30 Continuation Sheet(s)
NOTE: Proposal Receipt date is 11 September 2018 at 2:00 PM Central Time.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 2
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X 9A. AMENDMENT OF SOLICITATION NO.
W9126G18B0035
X 9B. DATED (SEE ITEM 11)
23-Aug-2018
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
August 27, 2018
CODE
US ARMY ENGINEER DISTRICT, FORT WORTH
ATTN: CESWF-CT
819 TAYLOR ST, ROOM 2A19
P.O. BOX 17300
FORT WORTH TX 76102-0300
W9126G 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W9126G18B0035
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
Commissioning Authority as required in section 01 35 13.03 44 is not required on this project.
CHANGES TO THE SPECIFICATIONS
1. FURNITURE, FIXTURES AND EQUIPMENT: A FF&E document has been added to the solicitation, bearing the notation W9126G18B0035-0002.
2. Replacement Sections - Replace the following sections with the accompanying new sections of the same number and title, bearing the notation W9126G18B0035-0002.
01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS
CHANGES TO THE DRAWINGS
3. Replacement Drawings.- Replace the drawings listed below with the attached new drawings(s) of the same number, bearing the notation W9126G18B0035-0002.
S-001 STRUCTURAL GENERAL NOTES
End of Summary of Changes
US Army Corps of Engineers
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
Renovate Building 56
Fort Sam Houston, TX
A-E Contract No:
W9126G-11-D-0034, TASK ORDER 0036, MOD 02
FURNITURE, FIXTURES AND
EQUIPMENT
FF&E
Issued For Construction
W9126G18B0035-0002
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
TABLE OF CONTENTS
1. FURNITURE, FIXTURES AND EQUIPMENT
FINISHES
1. Design Narrative
2. Point of Contact List
3. Furniture Cost Estimate
4. Interior Renderings and Order
Information
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
Design Narrative
The project design intent is to follow the Task Order Statement of Work program and building design concept. The team will focus on creating an atmosphere that is environmentally-friendly and ergonomic. The design intent for the furniture layout gives the space adaptability and flexibility to accommodate change over time.
The selection of interior finishes address the functionality of the space and enhance the aesthetic design intent. Colors, finishes and accessories have been selected to contribute to the health and sense of well-being of the building users and to create an identity for the building, while also addressing considerations for durability and life-cycle costs.
Furniture was provided for its functionality, ergonomics, durability and aesthetic features. The systems furniture combines a fence wall (power & data), work surface, personal/file pedestals, privacy panels, triple monitor arm, and CPU holders to create a custom work space. Consideration was given to the chairs by selecting seating for the expected duration of occupancy by one person. Seating that will require at least eight hours occupancy will have fully adjustable seating with multi-directional moving arms that will allow for comfortable seating and also allows full adjustability and movement. All chairs shall have hard wheeled casters to complement the carpeting floor finishes.
The interior design project goal is to provide a well-designed, sustainable, and comfortable environment that enables the users to perform at their best. We recognize the commitment of establishing good sustainable goals early in the stages of programming and design and then carrying these goals forward through the means and methods of construction. Through the selection of appropriate interior material and construction practice these goals can be achieved.
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
Point of Contact List
Architect Exp Federal, Inc.
205 N. Michigan Avenue Suite 3800 Chicago, Illinois 60601 Telephone: 312-616-6192 Paul Zinni, AIA, NCARB, NCIDQ, LEED®AP Paul.Zinni@expfederal.com
Interior Designer Exp. Federal 205 N. Michigan Ave Suite 3800 Chicago, IL 60601 Telephone: 312.616.6192 Paul Zinni, AIA, NCARB, NCIDQ, LEED®AP Paul.Zinni@expfederal.com
Furniture Manufacturer Knoll 222 Merchandise Mart, Floor 11 Chicago, IL 60654 Kim Richey Telephone: 602.304.0100 Tucson Account Manager krichey@cisinphx.com
W9126G18B0035-0002 mailto:Paul.Zinni@expfederal.com mailto:Paul.Zinni@expfederal.com mailto:krichey@cisinphx.com
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
*Estimate based on GSA Pricing
Furniture Cost Estimate
Code Description Qty GSA Cost Per Unit GSA Extended Cost
Private Offices
PO1 PRIVATE OFFICE 6 $4,478.40 $ 26,870.40
Workstations
WS1 (2) 60"W x 24"D WORKSTATIONS 6 $ 7,070.80 $ 42,424.80
WS2 (4) 60"W x 24"D WORKSTATIONS 5 $ 10,921.90 $ 54,609.50
WS3 COLLABORATION WORK TABLE 3 $ 6,713.60 $ 20,140.80
Seating
CH1 TASK CHAIRS 60 $ 711.00 $ 42,660.00
CH2 GUEST CHAIRS 12 $ 588.00 $ 7,056.00
CH3 CAFÉ CHAIR 4 $ 223.50 $ 894.00
Tables
TA1 CAFÉ TABLE 1 $ 671.00 $ 671.00
TA2 CONFERENCE ROOM TABLE 1 $ 982.00 $ 982.00
Equipment
A1 SIDE-BY-SIDE REFRIGERATOR 1 $ 2,544.42 $ 2,544.42
A2 MICROWAVE OVEN 1 $ 577.01 $ 577.01
A3 COFFEE MACHINE 1 $ 779.88 $ 779.88
Total Furnishings
All Furnishings Sub Total $ 200,209.81
Estimated Frieght/Delivery/Installation $ 40,041.96
Power/Communication Hook-Up $ 50,052.45
Grand Total $ 290,304.22
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
Basis of design using KNOLL Systems and Products
PO1
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
PO1
ITEM Number Description Amount Unit GSA
Total GSA Cost
RDSP7230J(A)(F)1(M)(H)(L)(64
4D)(613)(613)
REFF PROFILES SINGLE PEDESTAL
CANTILEVERED DESK, 27 3/4"H
OVERALL; PEDESTAL ON RIGHT HAND
SIDE; 72"W x 30"D; STANDARD
CORNER GROMMET LOCATION;
METAL INTERIOR; OUTLINE PULL;
VENEER FINISH: DOVE GREY 645D;
PAINT: MEDIUM GREY SMOOTH 115;
LOCKS: MATTE SILVER 1 $1,227.20 $1,227.20
RRSP4224K(A)(F)1(M)(H)(L)(64
4D)(613)(613)
SINGLE PEDESTAL RETURN, 24"D; 27
3/4"H OVERALL; PEDESTAL ON LEFT
HAND SIDE; 42"W x 24"D; STANDARD
CORNER GROMMET LOCATION;
METAL INTERIOR; OUTLINE PULL;
VENEER FINISH: DOVE GREY 645D;
PAINT: MEDIUM GREY SMOOTH 115;
LOCKS: MATTE SILVER 1 $889.60 $889.60
3 ROAH72T0(1)-(H)(L)(644D)
OVERHEAD, 26 1/2 PLANNING
OVERDESK UNIT, USE W/ 1 1/4"
WORKSURFACES; HINGE DOOR; 72"W
X 15"D x 44 1/4"H; 2 LOCKS (MATTE
SILVER); 4 DOORS; VENEER FINISH;
OUTLINE PULL
VENEER FINISH: DOVE GREY 645D;
PAINT: MEDIUM GREY SMOOTH 115;
FABRIC: CIRCUIT IN COIL
W17545;LOCKS: MATTE SILVER 1 $1,453.20 $1,453.20
4 RDTGB(111)
DESKTOP GROMMET FOR 1 1/4" THICK
TOP; JET BLACK 2 $14.80 $29.60
5 LED 2 IN 37 I
ANTENNA LED LIGHT SERIES:
HIGHWIRE INTERNATIONAL; 37"
UNDERCABINET LED LIGHT W/ POWER
SOURCE 1 $218.40 $218.40
6 LED PIR UNIVERSAL OCCUPANCY SENSOR 1 $41.60 $41.60
7 XYZ MA D CLMP K (111)
SAPPER XYZ MONITOR ARM SERIES
EASY ORDER DUAL SAPPER XYZ ARM
KIT
COLOR: JET BLACK 1 $331.60 $331.60
8 OA-CPU2-SLNG
ADJUSTABLE SLING CPU HOLDER, 16"
TRACK 2 $143.60 $287.20
TOTAL $4,478.40
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
Basis of design using KNOLL Systems and Products
WS1
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
WS1 ITEM NUMBER DESCRIPTION Amount Unit GSA Total GSA Cost
1 YT6024L
ANTENNA TOPS, 24"D x
60"W RECTANGULAR
LAMINATE WORKSURFACE
W/ GROMMETS
TOP FINISH: FOLKSTONE
GREY 114
EDGE FINISH: FOLKSTONE
GREY
2 $181.00 $362.00
2 YELD24
ANTENNA DESK HEIGHT
END LEGS FOR 24"D TOP;
21"D x 1"W x 27"H
LEG PAINT FINISH:
MEDIUM GREY
CRADLE PAINT FINISH:
MEDIUM GREY 4 $162.50 $650.00
3 YPSI1424F
ANTENNA INTERMEDIATE
SCREENS, FABRIC, FOR
42"H HORIZON; FULL
DEPTH INTERMEDIATE
SCREEN; 1 1/4"W x 24"D x 14"H
FABRIC: CIRCUIT IN COIL
W17545 1 $316.50 $316.50
4 OA-CPU2-SLNG
ADJUSTABLE SLING CPU
HOLDER, 16" TRACK 6 $143.60 $861.60
5 APF 1860
CURRENTS FENCH FRAME
60"W x 5"D x 20 1/2"H 2 $322.50 $645.00
6 AX1LEG6()
CURRENTS FENCE FRAME
LEG W/ GLIDE; 6"H 4 $41.50 $166.00
7 AX1 FF() STABILIZER FEET (SET OF 2) 2 $64.50 $129.00
8 APTA 60()
CURRENTS CROWN
COVERS, COMPACT (PAIR)
INTEGRAL COLOR; 60"W x 5"D 2 $39.00 $78.00
9 YPSF1760F
FENCE SCREENS, FABRIC
FOR 25"H FENCE FRAME,
42"H HORIZON; 60"W x 1 1/4"D x 17"H 2 $414.00 $828.00
10 APR 60 () ()
CURRENTS FENCE
RACEWAY COVERS (PAIR)
W/ OUTLETS; 60"W 2 $22.40 $44.80
11 APC OC ()
9"H x 12"W ACCESS
OUTLETS COVER
FINISH: 4 $17.00 $68.00
12 AR O OUTLET FILLERS (SET OF 10) 1 $19.50 $19.50
13 APC 0948 F ()
9" H x 48"W UPHOLSTERED
WALL COVERS
FABRIC: 2 $58.00 $116.00
14 APC 0960 C ()
9"H x 60"WCABLE TRAY
COVERS
FINISH: 2 $93.50 $187.00
15 YSMPDF18(L)L
ANTENNA MOBILE
PERSONAL/FILE PEDESTAL,
FULL TOP; LAMINATE
FRONT; 18"D x 15"W x 22"H
LAMINATE: FOLKSTONE
GREY ; PAINT: FOLKSTONE
GREY SMOOTH 2 $674.50 $1,349.00
16 YAPTN
PENCIL TRAY, BLACK
FINISH; 13 1/4" x 5 7/8" x 7/8" 4 $22.00 $88.00
17 OA-CPU2-SLNG
ADJUSTABLE SLING CPU
HOLDER, 16" TRACK 2 $287.20 $574.40
18 SAP MA 3 CLMP K 111
SAPPER TRIPLE MONITOR
ARM, TWO-PIECE TABLE
CLAMP
FINISH: BLACK 2 $294.00 $588.00
TOTAL $7,070.80
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
Basis of design using KNOLL Systems and Products
WS2
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
WS2 ITEM NUMBER DESCRIPTION Amount Unit GSA Total GSA Cost
1 YT6024L
ANTENNA TOPS, 24"D x
60"W RECTANGULAR
LAMINATE WORKSURFACE
W/ GROMMETS
TOP FINISH: FOLKSTONE
GREY 114
EDGE FINISH: FOLKSTONE
GREY
4 $181.00 $724.00
2 YELD24
ANTENNA DESK HEIGHT
END LEGS FOR 24"D TOP;
21"D x 1"W x 27"H
LEG PAINT FINISH: MEDIUM
GREY
CRADLE PAINT FINISH:
MEDIUM GREY 8 $162.50 $1,300.00
3 YPSI1424F
ANTENNA INTERMEDIATE
SCREENS, FABRIC, FOR 42"H
HORIZON; FULL DEPTH
INTERMEDIATE SCREEN; 1
1/4"W x 24"D x 14"H
FABRIC: CIRCUIT IN COIL
W17545 2 $316.50 $633.00
4 OA-CPU2-SLNG
ADJUSTABLE SLING CPU
HOLDER, 16" TRACK 12 $143.60 $1,723.20
5 APF 1860
CURRENTS FENCH FRAME
60"W x 5"D x 20 1/2"H 2 $322.50 $645.00
6 AX1LEG6()
CURRENTS FENCE FRAME
LEG W/ GLIDE; 6"H 4 $41.50 $166.00
7 AX1 FF() STABILIZER FEET (SET OF 2) 2 $64.50 $129.00
8 APTA 60()
CURRENTS CROWN
COVERS, COMPACT (PAIR)
INTEGRAL COLOR; 60"W x 5"D 2 $39.00 $78.00
9 YPSF1760F
FENCE SCREENS, FABRIC
FOR 25"H FENCE FRAME,
42"H HORIZON; 60"W x 1 1/4"D x 17"H
FABRIC: CIRCUIT IN COIL
W17545 2 $414.00 $828.00
10 APR 60 () ()
CURRENTS FENCE
RACEWAY COVERS (PAIR)
W/ OUTLETS; 60"W 2 $28.00 $56.00
11 APC OC ()
9"H x 12"W ACCESS
OUTLETS COVER
FINISH: FOLKSTONE GREY 4 $17.00 $68.00
12 AR O OUTLET FILLERS (SET OF 10) 1 $19.50 $19.50
13 APC 0948 F ()
9" H x 48"W UPHOLSTERED
WALL COVERS
FABRIC: CIRCUIT IN COIL
W17545 2 $58.00 $116.00
14 APC 0960 C ()
9"H x 60"WCABLE TRAY
COVERS
FINISH: 2 $93.50 $187.00
15 YSMPDF18(L)L
ANTENNA MOBILE
PERSONAL/FILE PEDESTAL,
FULL TOP; LAMINATE
FRONT; 18"D x 15"W x 22"H
LAMINATE: FOLKSTONE
GREY; PAINT: FOLKSTONE
GREY 4 $674.50 $2,698.00
16 YAPTN
PENCIL TRAY, BLACK FINISH;
13 1/4" x 5 7/8" x 7/8" 4 $22.00 $88.00
17 OA-CPU2-SLNG
ADJUSTABLE SLING CPU
HOLDER, 16" TRACK 2 $143.60 $287.20
18 SAP MA 3 CLMP K 111
SAPPER TRIPLE MONITOR
ARM, TWO-PIECE TABLE
CLAMP
FINISH: BLACK 4 $294.00 $1,176.00
TOTAL $10,921.90
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
Basis of design using KNOLL Systems and Products
WS3
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
WS3 ITEM NUMBER DESCRIPTION Amount Unit Cost Total Cost
1 YELDD50
Antenna Desk Height End Leg for Dual Big Tables; For 24"D Dual Sided Big Table; 50 1/2"D x 1"W x 27"H
PAINT: MEDIUM GREY 6 $ 234.00 $ 1,404.00
2 YT4224
Antenna Tops, 24"D Rectangular;
42"W x 24"D x 1 1/4" TH Laminate: FOLKSTONE GREY 114 Edgeband: FOLKSTONE GREY 6 $ 133.60 $ 801.60
3 YBRS39
Starter Rails w/o End Caps, For Use w/ Antenna Tops w/ Two Extension Tops (Pair); For 42"W Desk; 39" x 1" x 1" Paint: MEDIUM GREY 1 $ 54.40 $ 54.40
4 YBRE42
Extended Rails (pair), For 42"W Desk;
42"W x 1"D x 1"H Paint: MEDIUM GREY 2 $ 45.20 $ 90.40
5 YCBT42
Center Beam (Drilled for T-Light Cable), For 42"W Big Table Top; 42"W x 3"D x 3 1/4"H 3 $ 121.60 $ 364.80
6 YCBPE
Center Beam End Caps (Full Height Shown), Partial Height For Use w/ Extension Top or Cabinets 2 $ 13.00 $ 26.00
7 YR1EDPI 2+2 Modular Base Infeed 1 $ 85.20 $ 85.20
8 YR1CP
Covers for Exposed End of Power Harness (Package of 10) 1 $ 78.80 $ 78.80
9 YRCE Raceway End Cap (Package of 2) 1 $ 7.20 $ 7.20
10 YR1C18D
Raceway Covers (pair), For 12"W Power Harness, Outlets b/ Sides 3 $ 42.00 $ 126.00
11 YRPHE12
Power Harness; 2+2, (2) Duplex Outlets per Side; 12"W x 2"D x 2"H 3 $ 77.20 $ 231.60
12 YRPHA30
Power Harness Mounting Brackets for Desks, For Desk Mounted 12"W Power Harness and Communications Mounting Box 3 $ 39.20 $ 117.60
13 YR1CMB Communications Mounting Box 1 $ 17.20 $ 17.20
14 YR1DA Duplex Receptacles, Circuit A, Black 3 $ 44.00 $ 132.00
15 YR1DB Duplex Receptacles, Circuit B, Black 3 $ 44.00 $ 132.00
16 YR1DX Duplex Receptacles, Circuit X, Black 3 $ 44.00 $ 132.00
17 YR1DY Duplex Receptacles, Circuit Y, Black 3 $ 44.00 $ 132.00
18 YROF Outlet Fillers (Package of 10) 1 $ 38.00 $ 38.00
19 YR1CB3912B
Upper Cable Baskets (39" x 12" w/ 4"H Mount) 3 $ 66.80 $ 200.40
20 YR1CBC66
Antenna Wire Basket Cover (Pair), Attaches to both Lower and Upper Cable Basket of the same depth;
66"W x 1/12"D x 3 3/4"H 1 $ 86.40 $ 86.40
21 YR1CBE12
Antenna Wire Basket End Cap (Pair);
12"D x 1 1/8"W x 3 3/4"H 1 $ 62.80 $ 62.80
22 YR1VWM323
Vertical Infeed/Wire Manager, For Desk Height Table 1 $ 164.40 $ 164.40
24 YSMPDF18(L)L
ANTENNA MOBILE PERSONAL/FILE
PEDESTAL, FULL TOP; LAMINATE
FRONT; 18"D x 15"W x 22"H
LAMINATE: FOLKSTONE GREY 114;
PAINT: FOLKSTONE GREY 4 $ 1,349.00 $ 2,158.40
25 YAPTN
PENCIL TRAY, BLACK FINISH; 13 1/4" x 5 7/8" x 7/8" 4 $ 44.00 $ 70.40
Total $6,713.60
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
Product Specification:
Item Name: Task Chair
Item Number: CH1
Manufacturer: Knoll
Style Name/Number: Generation 11-1-HP-2-S-X-HC-DK-04-USF-GENU06
Description: Frameless flex back w/ multidimensional movement and continuous lumbar support, high performance arms, and a flex seat that offers 270 degrees of unobstructed seat edge flex & 3” of seat depth adjustment, and dynamic suspension;
hard casters; 28.5”W x 26”D (excluding base) x 39.25-44.5”H x 16.5-21.75”SH x
22.75-32.5” Arm Height
Finishes: Base: Polished Aluminum; Frame: Light; Casters: Hard Wheel; Back Net:
Espresso; Seat: Espresso
SEATING
Quantity 60
Price per unit $711.00
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
Product Specification:
Item Name: Guest Chair
Item Number: CH2
Manufacturer: Knoll
Style Name/Number: Krusin Arm Chair / MK01A-J-K1925/14
Description: Marc Krusin Arm Chair; 18 1/3”SH x 24 ½” AH x 23 ½”W x 21 ¾”D x 30
½”H
Finishes: Beech Frame Finish: Ebonized; Fabric: Prairie in Coyote
SEATING
Quantity 12
Price per unit $588.00
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
Product Specification:
Item Name: Café Chair
Item Number: CH3
Manufacturer: Knoll
Style Name/Number: Gigi Chair / 87C-(014)
Description: Armless Chair, Stacking; Polypropylene shell on a chrome-plated base;
18”SH x 19 ¾”W x 20”D x 34 ¼”H
Color: Black 014
SEATING
Quantity 4
Price per unit $223.50
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
Product Specification:
Item Name: Café Table
Item Number: TA1
Manufacturer: Knoll
Style Name/Number: Dividends Horizon X Base Table / DT1ACX48
Description: 28” High Round X Base Table; 48”Dia.
Color: Base Paint: Medium Grey – Smooth 115; Top: Bright White 118; Edge:
TABLES
Quantity 1
Price per unit $671.00
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
Product Specification:
Item Name: Conference Room Table
Item Number: TA2
Manufacturer: Knoll
Style Name/Number: Dividends Horizon Y Leg Table/ DT1ARY7236E
Description: 36”D Rectangular Table w/ (2) Y-Legs; w/Grommet
Color: Textured Paint: Medium Grey 115T; Top: Graphite Pear; Edge: Graphite Pear
TABLES
Quantity 1
Price per unit $982.00
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
Product Specification:
Item Name: Side-By-Side Refrigerator
Item Number: EQ1
Manufacturer: Samsung
Style Name/Number: RH22H9010SR/AA
Description: 22 Cu Ft. stainless steel side-by-side food showcase refrigerator w/ metal cooling S.S. paneling 36”W x 28 11/32”D x 69 27/32”H
Finishes: Stainless Steel
EQUIPMENT
Quantity 1
Price per unit $2,544.42
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
Product Specification:
Item Name: Microwave oven
Item Number: EQ2
Manufacturer: GE
Style Name/Number: PEB9159SFSS
Description: 20”L x 22.635”W
Finishes: Stainless Steel/ Black
EQUIPMENT
Quantity 1
Price per unit $577.01
Fort Worth District
Furniture, Fixtures & Equipment
(FF&E)
6/15/2018
Product Specification:
Item Name: Coffee Machine
Item Number: EQ3
Manufacturer: Bunn
Style Name/Number: VLPF Brewer 07400.0005
Description: One Brewer, Two Warmers w/ Hot Water Feature; Plumbing Required;
23.5”W x 13.1”D x 17.4”H
Finishes: Stainless Steel/ Black
EQUIPMENT
Quantity 1
Price per unit $779.88
Bldg 56 Renovation FSH18ANB56
SECTION 01 50 00
TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN WATER WORKS ASSOCIATION (AWWA)
AWWA C511 (2007) Standard for Reduced-Pressure Principle Backflow Prevention Assembly
FOUNDATION FOR CROSS-CONNECTION CONTROL AND HYDRAULIC RESEARCH
(FCCCHR)
FCCCHR List (continuously updated) List of Approved Backflow Prevention Assemblies
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 241 (2013; Errata 2015) Standard for Safeguarding Construction,Alteration, and Demolition Operations
NFPA 70 (2014; AMD 1 2013; Errata 1 2013; AMD 2 2013; Errata 2 2013; AMD 3 2014; Errata 3-4 2014; AMD 4-6 2014) National Electrical Code
U.S. FEDERAL AVIATION ADMINISTRATION (FAA)
FAA AC 70/7460-1 (2015; Rev L) Obstruction Marking and Lighting
U.S. FEDERAL HIGHWAY ADMINISTRATION (FHWA)
MUTCD (2009) Manual on Uniform Traffic Control Devices
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-01 Preconstruction Submittals
Construction Site Plan; G
SECTION 01 50 00 Page 1
Traffic Control Plan; G
SD-06 Test Reports
Backflow Preventer Tests
SD-07 Certificates
Backflow Tester Certification
Backflow Preventers Certificate of Full Approval
1.3 CONSTRUCTION SITE PLAN
Prior to the start of work, submit a site plan showing the locations and dimensions of temporary facilities (including layouts and details, equipment and material storage area (onsite and offsite), and access and haul routes, avenues of ingress/egress to the fenced area and details of the fence installation. Identify any areas which may have to be graveled to prevent the tracking of mud. Indicate if the use of a supplemental or other staging area is desired. Show locations of safety and construction fences, site trailers, construction entrances, trash dumpsters, temporary sanitary facilities, and worker parking areas.
1.4 BACKFLOW PREVENTERS CERTIFICATE
Certificate of Full Approval from FCCCHR List, University of Southern California, attesting that the design, size and make of each backflow preventer has satisfactorily passed the complete sequence of performance testing and evaluation for the respective level of approval. Certificate of Provisional Approval will not be acceptable.
1.4.1 Backflow Tester Certificate
Prior to testing, submit to the Contracting Officer certification issued by the State or local regulatory agency attesting that the backflow tester has successfully completed a certification course sponsored by the regulatory agency. Tester must not be affiliated with any company participating in any other phase of this Contract.
1.4.2 Backflow Prevention Training Certificate
Submit a certificate recognized by the State or local authority that states the Contractor has completed at least 10 hours of training in backflow preventer installations. The certificate must be current.
PART 2 PRODUCTS
2.1 TEMPORARY SIGNAGE
2.1.1 Bulletin Board
Immediately upon beginning of work, provide a weatherproof glass-covered bulletin board not less than 36 by 48 inches in size for displaying the Equal Employment Opportunity poster, a copy of the wage decision contained in the contract, Wage Rate Information poster, and other information approved by the Contracting Officer.
SECTION 01 50 00 Page 2
2.1.2 Project and Safety Signs
The requirements for the signs, their content, and location are as specified in Section 01 58 00 PROJECT IDENTIFICATION. Erect signs within 15 days after receipt of the notice to proceed. Correct the data required by the safety sign daily, with light colored metallic or non-metallic numerals.
2.2 TEMPORARY TRAFFIC CONTROL
2.2.1 Haul Roads
Construct access and haul roads necessary for proper prosecution of the work under this contract. Construct with suitable grades and widths; sharp curves, blind corners, and dangerous cross traffic are be avoided. Provide necessary lighting, signs, barricades, and distinctive markings for the safe movement of traffic. The method of dust control, although optional, must be adequate to ensure safe operation at all times. Location, grade, width, and alignment of construction and hauling roads are subject to approval by the Contracting Officer. Lighting must be adequate to assure full and clear visibility for full width of haul road and work areas during any night work operations.
2.2.2 Barricades
Erect and maintain temporary barricades to limit public access to hazardous areas. Whenever safe public access to paved areas such as roads, parking areas or sidewalks is prevented by construction activities or as otherwise necessary to ensure the safety of both pedestrian and vehicular traffic barricades will be required. Securely place barricades clearly visible with adequate illumination to provide sufficient visual warning of the hazard during both day and night.
2.2.3 Fencing
Provide fencing along the construction site at all open excavations and tunnels to control access by unauthorized people.
a. The safety fencing must be a high visibility orange colored, high density polyethylene grid or approved equal, a minimum of 48 inches high and maximum mesh size of 2 inches, supported and tightly secured to steel posts located on maximum 10 foot centers, constructed at the approved location. Install fencing to be able to restrain a force of at least 250 pounds against it.
2.2.4 Temporary Wiring
Provide temporary wiring in accordance with NFPA 241 and NFPA 70. Include frequent inspection of all equipment and apparatus.
2.2.5 Backflow Preventers
Reduced pressure principle type conforming to the applicable requirements AWWA C511. Provide backflow preventers complete with 150 pound flanged , bronze or brass mounted gate valve and strainer, 304 stainless steel or bronze, internal parts.
SECTION 01 50 00 Page 3
PART 3 EXECUTION
3.1 EMPLOYEE PARKING
Contractor employees will park privately owned vehicles in an area designated by the Contracting Officer. This area will be within reasonable walking distance of the construction site. Contractor employee parking must not interfere with existing and established parking requirements of the government installation.
3.2 TEMPORARY BULLETIN BOARD
Locate the bulletin board at the project site in a conspicuous place easily accessible to all employees, as approved by the Contracting Officer.
3.3 AVAILABILITY AND USE OF UTILITY SERVICES
3.3.1 Temporary Utilities
Provide temporary utilities required for construction. Materials may be new or used, must be adequate for the required usage, not create unsafe conditions, and not violate applicable codes and standards.
3.3.2 Payment for Utility Services
a. The Government will make all reasonably required utilities available to the Contractor from existing outlets and supplies, as specified in the contract. Unless otherwise provided in the contract, the amount of each utility service consumed will be charged to or paid for by the Contractor at prevailing rates charged to the Government or, where the utility is produced by the Government, at reasonable rates determined by the Contracting Officer. Carefully conserve any utilities furnished without charge.
b. Reasonable amounts of the following utilities will be made available to the Contractor at the prevailing rates.
c. The point at which the Government will deliver such utilities or services and the quantity available is as indicated. Pay all costs incurred in connecting, converting, and transferring the utilities to the work. Make connections, including providing backflow-preventing devices on connections to domestic water lines; and providing transformers; and make disconnections.
3.3.3 Meters and Temporary Connections
At the Contractors expense and in a manner satisfactory to the Contracting Officer, provide and maintain necessary temporary connections, distribution lines, and meter bases (Government will provide meters) required to measure the amount of each utility used for the purpose of determining charges.
Notify the Contracting Officer, in writing, 5 working days before final electrical connection is desired so that a utilities contract can be established. The Government will provide a meter and make the final hot connection after inspection and approval of the Contractor's temporary wiring installation. The Contractor will not make the final electrical connection.
SECTION 01 50 00 Page 4
3.3.4 Advance Deposit
An advance deposit for utilities consisting of an estimated month's usage or a minimum of $50.00 will be required. The last monthly bills for the fiscal year will normally be offset by the deposit and adjustments will be billed or returned as appropriate. Services to be rendered for the next fiscal year, beginning 1 October, will require a new deposit. Notification of the due date for this deposit will be mailed to the Contractor prior to the end of the current fiscal year.
3.3.5 Final Meter Reading
Before completion of the work and final acceptance of the work by the Government, notify the Contracting Officer, in writing, 5 working days before termination is desired. The Government will take a final meter reading, disconnect service, and remove the meters. Then remove all the temporary distribution lines, meter bases, and associated paraphernalia.
Pay all outstanding utility bills before final acceptance of the work by the Government.
3.3.6 Sanitation
a. Provide and maintain within the construction area minimum field-type sanitary facilities approved by the Contracting Officer and periodically empty wastes into a municipal, district, or station sanitary sewage system, or remove waste to a commercial facility.
Obtain approval from the system owner prior to discharge into any municipal, district, or commercial sanitary sewer system. Any penalties and / or fines associated with improper discharge will be the responsibility of the Contractor. Coordinate with the Contracting Officer and follow station regulations and procedures when discharging into the station sanitary sewer system. Maintain these conveniences at all times without nuisance. Include provisions for pest control and elimination of odors. Government toilet facilities will not be available to Contractor's personnel.
3.3.7 Telephone
Make arrangements and pay all costs for telephone facilities desired.
3.3.8 Obstruction Lighting of Cranes
Provide a minimum of 2 aviation red or high intensity white obstruction lights on temporary structures (including cranes) over 100 feet above ground level. Light construction and installation must comply with FAA AC 70/7460-1. Lights must be operational during periods of reduced visibility, darkness, and as directed by the Contracting Officer.
3.3.9 Fire Protection
Provide temporary fire protection equipment for the protection of personnel and property during construction. Remove debris and flammable materials daily to minimize potential hazards.
3.4 TRAFFIC PROVISIONS
3.4.1 Maintenance of Traffic
a. Conduct operations in a manner that will not close any thoroughfare or
SECTION 01 50 00 Page 5 interfere in any way with traffic on railways or highways except with written permission of the Contracting Officer at least 15 calendar days prior to the proposed modification date, and provide a Traffic Control Plan detailing the proposed controls to traffic movement for approval.
The plan must be in accordance with State and local regulations and the MUTCD, Part VI. Make all notifications and obtain any permits required for modification to traffic movements outside Station's jurisdiction..
Contractor may move oversized and slow-moving vehicles to the worksite provided requirements of the highway authority have been met.
b. Conduct work so as to minimize obstruction of traffic, and maintain traffic on at least half of the roadway width at all times. Obtain approval from the Contracting Officer prior to starting any activity that will obstruct traffic.
c. Provide, erect, and maintain, at contractors expense, lights, barriers, signals, passageways, detours, and other items, that may be required by the Life Safety Signage, overhead protection authority having jurisdiction.
3.4.2 Protection of Traffic
Maintain and protect traffic on all affected roads during the construction period except as otherwise specifically directed by the Contracting Officer. Measures for the protection and diversion of traffic, including the provision of watchmen and flagmen, erection of barricades, placing of lights around and in front of equipment the work, and the erection and maintenance of adequate warning, danger, and direction signs, will be as required by the State and local authorities having jurisdiction. Protect the traveling public from damage to person and property. Minimize the interference with public traffic on roads selected for hauling material to and from the site. Investigate the adequacy of existing roads and their allowable load limit. Contractor is responsible for the repair of any damage to roads caused by construction operations.
3.4.3 Rush Hour Restrictions
Do not interfere with the peak traffic flows preceding and during normal operations without notification to and approval by the Contracting Officer.
3.4.4 Dust Control
Dust control methods and procedures must be approved by the Contracting Officer. Treat dust abatement on access roads with applications of calcium chloride, water sprinklers, or similar methods or treatment.
3.5 CONTRACTOR'S TEMPORARY FACILITIES
3.5.1 Safety
Protect the integrity of any installed safety systems or personnel safety devices. If entrance into systems serving safety devices is required, the Contractor must obtain prior approval from the Contracting Officer. If it is temporarily necessary to remove or disable personnel safety devices in order to accomplish contract requirements, provide alternative means of protection prior to removing or disabling any permanently installed safety devices or equipment and obtain approval from the Contracting Officer.
SECTION 01 50 00 Page 6
3.5.2 Administrative Field Offices
Provide and maintain administrative field office facilities within the construction area at the designated site. Government office and warehouse facilities will not be available to the Contractor's personnel.
3.5.3 Storage Area
Construct a temporary 6 foot high chain link fence around trailers and materials. Include plastic strip inserts, colored brown, so that visibility through the fence is obstructed. Fence posts may be driven, in lieu of concrete bases, where soil conditions permit. Do not place or store Trailers, materials, or equipment outside the fenced area unless such trailers, materials, or equipment are assigned a separate and distinct storage area by the Contracting Officer away from the vicinity of the construction site but within the installation boundaries. Trailers, equipment, or materials must not be open to public view with the exception of those items which are in support of ongoing work on any given day. Do not stockpile materials outside the fence in preparation for the next day's work. Park mobile equipment, such as tractors, wheeled lifting equipment, cranes, trucks, and like equipment within the fenced area at the end of each work day.
3.5.4 Supplemental Storage Area
Upon Contractor's request, the Contracting Officer will designate another or supplemental area for the Contractor's use and storage of trailers, equipment, and materials. This area may not be in close proximity of the construction site but will be within the installation boundaries. Fencing of materials or equipment will not be required at this site; however, the Contractor is responsible for cleanliness and orderliness of the area used and for the security of any material or equipment stored in this area.
Utilities will not be provided to this area by the Government.
3.5.5 Appearance of Trailers
a. Trailers utilized by the Contractor for administrative or material storage purposes must present a clean and neat exterior appearance and be in a state of good repair. Trailers which, in the opinion of the Contracting Officer, require exterior painting or maintenance will not be allowed on installation property.
b. Paint using suitable paint and maintain the temporary facilities.
Failure to do so will be sufficient reason to require their removal.
3.5.6 Maintenance of Storage Area
a. Keep fencing in a state of good repair and proper alignment. Grassed or unpaved areas, which are not established roadways, will be covered with a layer of gravel as necessary to prevent rutting and the tracking of mud onto paved or established roadways, should the Contractor elect to traverse them with construction equipment or other vehicles; gravel gradation will be at the Contractor's discretion. Mow and maintain grass located within the boundaries of the construction site for the duration of the project. Grass and vegetation along fences, buildings, under trailers, and in areas not accessible to mowers will be edged or trimmed neatly.
SECTION 01 50 00 Page 7
3.5.7 New Building
In the event a new building is constructed for the temporary project field office, it will be a minimum 12 feet in width, 16 feet in length and have a minimum of 7 feet headroom. Equip the building with approved electrical wiring, at least one double convenience outlet and the required switches and fuses to provide 110-120 volt power. Provide a work table with stool, desk with chair, two additional chairs, and one legal size file cabinet that can be locked. The building must be waterproof, supplied with a heater, have a minimum of two doors, electric lights, a telephone, a battery operated smoke detector alarm, a sufficient number of adjustable windows for adequate light and ventilation, and a supply of approved drinking water. Approved sanitary facilities must be furnished. Screen the windows and doors and provide the doors with dead bolt type locking devices or a padlock and heavy duty hasp bolted to the door. Door hinge pins will be non-removable. Arrange the windows to open and to be securely fastened from the inside. Protect glass panels in windows by bars or heavy mesh screens to prevent easy access. In warm weather, furnish air conditioning capable of maintaining the office at 50 percent relative humidity and a room temperature 20 degrees F below the outside temperature when the outside temperature is 95 degrees F. Any new building erected for a temporary field office must be maintained by the Contractor during the life of the contract and upon completion and acceptance of the work become the property of the Contractor and removed from the site.
3.5.8 Security Provisions
Provide adequate outside security lighting at the Contractor's temporary facilities. The Contractor will be responsible for the security of its own equipment; in addition, the Contractor will notify the appropriate law enforcement agency requesting periodic security checks of the temporary project field office.
3.5.9 Weather Protection of Temporary Facilities and Stored Materials
Take necessary precautions to ensure that roof openings and other critical openings in the building are monitored carefully. Take immediate actions required to seal off such openings when rain or other detrimental weather is imminent, and at the end of each workday. Ensure that the openings are completely sealed off to protect materials and equipment in the building from damage.
3.5.9.1 Building and Site Storm Protection
When a warning of gale force winds is issued, take precautions to minimize danger to persons, and protect the work and nearby Government property.
Precautions must include, but are not limited to, closing openings;
removing loose materials, tools and equipment from exposed locations; and removing or securing scaffolding and other temporary work. Close openings in the work when storms of lesser intensity pose a threat to the work or any nearby Government property.
<AM#0002>3.6 GOVERNMENT FIELD OFFICE
3.6.1 Resident Engineer's Office
Provide the Government Resident Engineer with an office, approximately 200 square feet in floor area, located where directed and providing space heat, electric light and power, and toilet facilities consisting of one lavatory
SECTION 01 50 00 Page 8 and one water closet complete with connections to water and sewer mains.
Provide a mail slot in the door or a lockable mail box mounted on the surface of the door. Include a 4 by 8 foot plan table, computer work space a standard size office desk and chair, and telephone. At completion of the project, the office will remain the property of the Contractor and be removed from the site. Utilities will be connected and disconnected in accordance with local codes and to the satisfaction of the Contracting Officer.
3.6.2 Quality Control Manager Records and Field Office
Provide on the jobsite an office with approximately 100 square feet of useful floor area for the exclusive use of the QC Manager. Provide a weathertight structure with adequate heating and cooling, toilet facilities, lighting, ventilation, a 4 by 8 foot plan table, a standard size office desk and chair, computer station, and working communications facilities. Provide a door with a cylinder lock and windows with locking hardware. Make utility connections. Locate as directed. File quality control records in the office and make available at all times to the Government. After completion of the work, remove the entire structure from the site.
3.6.3 Trailer-Type Mobile Office
The Contractor may, at its option, furnish and maintain a trailer-type mobile office acceptable to the Contracting Officer and providing as a minimum the facilities specified above. Securely anchor the trailer to the ground at all four corners to guard against movement during high winds.
</AM#0002>
3.6 PLANT COMMUNICATION
Whenever the Contractor has the individual elements of its plant so located that operation by normal voice between these elements is not satisfactory, the Contractor must install a satisfactory means of communication, such as telephone or other suitable devices and made available for use by Government personnel.
3.7 TEMPORARY PROJECT SAFETY FENCING
As soon as practicable, but not later than 15 days after the date established for commencement of work, furnish and erect temporary project safety fencing at the work site. Maintain the safety fencing during the life of the contract and, upon completion and acceptance of the work, will become the property of the Contractor and be removed from the work site.
3.8 CLEANUP
Remove construction debris, waste materials, packaging material and the like from the work site daily. Any dirt or mud which is tracked onto paved or surfaced roadways must be cleaned away. Store any salvageable materials resulting from demolition activities within the fenced area described above or at the supplemental storage area. Neatly stack stored materials not in trailers, whether new or salvaged.
3.9 RESTORATION OF STORAGE AREA
Upon completion of the project remove the bulletin board, signs, SECTION 01 50 00 Page 9 barricades, haul roads, and any other temporary products from the site.
After removal of trailers, materials, and equipment from within the fenced area, remove the fence that will become the property of the Contractor.
Restore areas used by the Contractor for the storage of equipment or material, or other use to the original or better condition. Remove gravel used to traverse grassed areas and restore the area to its original condition, including top soil and seeding as necessary.
-- End of Section --
SECTION 01 50 00 Page 10
F S
H B
S
D
W G
S-001
S T
R U
C T
U R
A L
G E
N E
R A
L
N
O T
E S
A
U
R B
A N
E K
A
U
R B
A N
E K
J
P
F I T
Z I N
G E
R
A N
S I
D
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
J U
N E
W G
D
B U
I L
D I N
G
M
U S
E U
M
A
N N
X
R
N
O V
A T
I O
N
F O
T
A M
H
O U
S T
O N
T
X
SHEET ID
ISSUED FOR CONSTRUCTION
F I L E
N A
M E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
C
US Army Corps of Engineers
C A
T E
G O
Y
C
D
E
U S
A
R M
Y
C
O R
P
F
E
N G
I N
E E
R S
T
A Y
L O
R
S
T R
E E
T
D E
S C
R I P
T I O
N
M
I C
H I G
V E
S U
I T
E
C H
I C
A G
O
I L
T w w w e x p f e d e r a l c o m p r o j n o
C
H I
A
F O
W
R
H
D
I S
T R
I C
T
F O
W
R
T H
T
E X
A S
P
Z
I N
N I
GENERAL REQUIREMENTS
1. "DRAWINGS" MEANS LATEST STRUCTURAL DESIGN DRAWINGS, UNO., "SPECIFICATIONS"
MEANS LATEST PROJECT SPECIFICATIONS, UNO.
2. THE SPECIFICATIONS ARE AN INTEGRAL PART OF THE CONTRACT DOCUMENTS AND SHALL
BE USED IN CONJUNCTION WITH THE STRUCTURAL DRAWINGS. IN CASES, IF ANY, WHERE
REQUIREMENTS INDICATED ON THE STRUCTURAL DRAWINGS DIFFER FROM THE
SPECIFICATIONS, NOTIFY THE DESIGNER OF RECORD. FOR PRICING, ASSUME THAT THE
MORE STRINGENT REQUIREMENT TAKES PRECEDENCE.
3. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL
AND SHALL BE CONSTRUED TO APPLY TO SIMILAR CONDITIONS ELSEWHERE.
4. THE CONTRACTOR SHALL FIELD CHECK AND VERIFY ALL EXISTING CONDITIONS AND
REPORT ANY DISCREPANCIES TO THE GOVERNMENT'S REPRESENTATIVE BEFORE
PROCEEDING WITH THE WORK.
5. NO OPENINGS SHALL BE MADE IN ANY STRUCTURAL MEMBER WITHOUT THE PRIOR
WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER.
6. NO CHANGE IN SIZE OR DIMENSION OF ANY STRUCTURAL MEMBER SHALL BE MADE
WITHOUT THE PRIOR WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LIMITING THE AMOUNT OF CONSTRUCTION
LOADS IMPOSED ON THE STRUCTURAL FRAMING. CONSTRUCTION LOADS SHALL NOT
EXCEED THE LESSER OF THE ALLOWABLE CONSTRUCTION LIVE LOAD AS INDICATED ON
THE CONTRACT DRAWINGS, OR THE CAPACITY OF THE FRAMING.
8. THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. AS A RESULT
OF THE CONSTRUCTION MEANS, METHODS, AND/OR SEQUENCES CHOSEN BY THE
CONTRACTOR, THE CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGNING AND
FURNISHING ALL TEMPORARY BRACING AND/OR SUPPORT THAT MAY BE REQUIRED TO
MAINTAIN STRUCTURAL INTEGRITY DURING CONSTRUCTION.
9. DO NOT SCALE DRAWINGS, USE DIMENSIONS. CENTERLINES OF COLUMNS AND
FOUNDATIONS COINCIDE WITH GRID LINE INTERSECTIONS, UNO. CENTERLINES OF FLOOR
FRAMING BEAMS AND GIRDERS COINCIDE WITH COLUMN CENTERLINES, UNO. ASSUME
EQUAL SPACING BETWEEN ESTABLISHED DIMENSIONS, IF NOT INDICATED ON DRAWINGS.
10. THE CONTRACTOR SHALL PROTECT EXISTING FACILITIES, STRUCTURES AND UTILITIES
FROM DAMAGE.
11. THE CONTRACTOR SHALL INFORM THE CONSTRUCTION MANAGER OR THE GOVERNMENT'S
ON-SITE REPRESENTATIVE IN WRITING OF ANY DEVIATION FROM THE CONTRACT
DOCUMENTS. THE CONTRACTOR SHALL NOT BE RELIEVED OF THE RESPONSIBILITY FOR
SUCH DEVIATION BASED UPON THE REVIEW OF SHOP DRAWINGS, PRODUCT DATA, ETC.,
UNLESS THE CONTRACTOR SPECIFICALLY INFORMED THE GOVERNMENT'S
REPRESENTATIVE OF SUCH DEVIATION AT THE TIME OF SUBMISSION, AND HAS BEEN
GIVEN WRITTEN APPROVAL FOR THE SPECIFIC DEVIATION.
12. SEE ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL, PLUMBING AND OTHER DESIGN
DRAWINGS FOR SCOPE OF WORK AND COORDINATION OF TRADES.
13. SEE CIVIL DRAWINGS FOR LOCATION OF CITY BENCHMARK WITH RESPECT TO BUILDING
LOCATION. SEE CIVIL DRAWINGS FOR SITE ELEMENTS AWAY FROM BUILDING FOOTPRINT.
14. PRINCIPAL OPENINGS ARE INDICATED ON THE DRAWINGS. SEE ARCHITECTURAL,
MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL OPENINGS,
BLOCK-OUTS AND SLEEVES. CONTRACTOR SHALL SUBMIT A COORDINATED PLAN
SHOWING ALL SLAB AND WALL OPENINGS, BLOCK-OUTS, AND SLEEVES TO THE
GOVERNMENT FOR REVIEW AND APPROVAL WITH EACH FLOOR AND WALL REINFORCING
SHOP DRAWING.
15. SEE ARCHITECTURAL DRAWINGS FOR LINTELS, SHELF ANGLES, HANDRAILS, GUARDRAILS,
PARTITION SUPPORT, COLUMN COVERS, EMBEDMENTS, EXPANSION JOINT ASSEMBLIES,
DOOR JAMBS, AND SIMILAR COMPONENTS.
16. SEE ARCHITECTURAL DRAWINGS FOR PARTITION ATTACHMENTS AND CURBS.
17. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH ALL APPLICABLE CITY, COUNTY, STATE AND FEDERAL LAWS, INCLUDING THE OCCUPATIONAL SAFETY AND HEALTH
ACT (OSHA) AND REGULATIONS ADOPTED PURSUANT THERETO.
18. CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT STRUCTURE,
WORKERS OR OTHER PERSONS DURING CONSTRUCTION. SUCH MEASURES SHALL
INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING FOR CONSTRUCTION EQUIPMENT,
SHORING FOR BUILDING, SHORING FOR EARTH BANKS, FORMS, SCAFFOLDING, PLANKING,
SAFETY NETS, SUPPORT AND BRACING FOR CRANES AND GIN POLES, ETC.
19. ELEVATION 0'-0" (IF INDICATED ON DRAWINGS) IS AT THE TOP OF SLAB-ON-GRADE
CONCRETE. REFER TO CIVIL DRAWINGS FOR CORRESPONDING ACTUAL SITE ELEVATIONS.
MINIMUM GRAVITY LOADS
SUPERIMPOSED DEAD LOADS (IN ADDITION TO SELF-WEIGHT OF STRUCTURAL SYSTEMS)
ROOF
METAL ROOF WITH INSULATION 6.0 PSF
SUB-BOARD W/ WATER PROTECTION 2.0 PSF
HVAC ALLOWANCE 1.0 PSF
LIGHTING / ELECTRICAL ALLOWANCE 1.0 PSF
ACOUSTICAL SUSPENDED CEILING ALLOWANCE 1.0 PSF
EXTERIOR ENCLOSURES
BRICK, LOAD-BEARING, 3 WYTHES WIDE (PER FT OF HT) 120 PSF
LIVE LOADS (LOADS GREATER OR EQUAL TO 100 PSF SHALL NOT BE REDUCED, UNO)
FLOOR
OFFICE 50 PSF
LOBBIES & CORRIDORS 100 PSF
LAVATORIES 75 PSF
PARTITIONS
UNIFORM LOAD UNLESS LIVE LOAD 80 PSF OR GREATER 15 PSF
ROOF
MINIMUM LIVE LOAD, L
r
(NON-REDUCIBLE) 20 PSF
GUARDRAIL/HANDRAIL
VERTICAL & HORIZONTAL THRUST TOP OF RAILING 50 PLF
CONCENTRATED LOAD ANY DIRECTION 200 LBS
MINIMUM ENVIRONMENTAL LOADS
SNOW LOADS
GROUND SNOW, Pg = 5 PSF
MINIMUM SNOW LOAD (Pg*I for Pg<20, 20*I for Pg>20) 5 PSF (LOW SLOPE)
IMPORTANCE FACTOR (RISK CATEGORY II), I
s
= 1.0
EXPOSURE FACTOR, "C" TERRAIN CATEGORY, C
e
= 0.9 (FULLY EXPOSED)
THERMAL FACTOR, ALL STRUCTURES, C
t
= 1.0
SLOPE FACTOR, UNOBSTRUCTED SLIPPERY, C
s
= 0.8 (4:12 SLOPE)
SNOW DRIFTS (PER ASCE 7-10, Ch. 7.7 & 7.8) SEE DIAGRAMS
RAIN-ON-SNOW SURCHARGE (ON BALANCED SNOW ONLY) 5 PSF
WIND LOADS
BASIC ULTIMATE WIND SPEED, v = 115 MPH
IMPORTANCE FACTOR (RISK CATEGORY II), I
W
= 1.0
EXPOSURE CATEGORY C
TOPOGRAPHIC FACTOR, K
zt
= 1.0
DIRECTIONALITY FACTOR, K
d
= 0.85
ENCLOSURE CLASSIFICATION ENCLOSED
INTERNAL PRESSURE COEFFICIENT, GC
pi
= +/- 0.18
COMPONENTS & CLADDING (PER ASCE 7-10, Ch. 26) SEE DIAGRAMS
BUILDING HEIGHT "H" DRIFT LIMIT H/600
SEISMIC LOADS
S s
(S ds
) 0.081 (0.086) g
S
(S d1
) 0.030 (0.048) g
SOIL SITE CLASSIFICATION D (ASSUMED)
IMPORTANCE FACTOR (RISK CATEGORY II), I
e
= 1.0
SEISMIC DESIGN CATEGORY, SDC A
SEISMIC FORCE RESISTANCE SYSTEM (SFRS)
BUILDING 259: A.11 ORDINARY PLAIN MASONRY SHEAR WALLS
SEISMIC ANALYSIS PROCEDURE EQ. LATERAL FORCE
ATFP REQUIREMENTS
BUILDING
DESIGNATION
CONTROL
PERIMETER
BUILDING
CATEGORY
LEVEL OF
PROTECTION
STANDOFF
DISTANCE
BLDG 56 WITHIN INHABITED VLLOP 23 FT
LOOSE MASONRY LINTELS
1. UNLESS OTHERWISE SHOWN ON DRAWINGS, STEEL LINTELS FOR NON-LOAD BEARING
MASONRY WALLS ONLY SHALL HAVE A MINIMUM SIZE AND END BEARING AS…