Thieme Drive Q & A May 27, 2010

Q1. Attached material information for welded wire gabions that are pvc coated. Can you review and let us know if welded wire gabions are acceptable?

A1. Welded wire gabions are NOT an acceptable substitute. Bid as shown in the plans and specifications.

Q2. The stone fill for the gabions under specification 2.1.4.2 requires a Los Angeles machine loss not to exceeed 25. The local quarries have informed me that their stone falls in the 30-32 range. The closest source would be Toledo, OH to meet this specification. Please let me know if the local range of 30-32 would be acceptable?

A2. The upper limit Los Angeles machine value of 32 is acceptable. An amendment will be forthcoming.