W911WN-17-B-8002_-_Plans.pdf
PDF 3 MB Posted
- Attached to
- Braddock Dam Gate Control Upgrade Federal contract opportunity
- Solicitation number
- W911WN-17-B-8002
About this file
Plans
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| BidResults.pdf | ||
| W911WN-17-B-8002_0002.pdf | ||
| 40_95_00.pdf | ||
| braddock_V04.RSS | RSS file | |
| Site_Visit_Sign-Up_Sheet.pdf | ||
| Updated_Specifications_40_95_00.pdf | ||
| Braddock_Water_HMI_Project.zip | ZIP file | |
| W911WN-17-B-8002_0001.pdf | ||
| W911WN-17-B-8002.pdf | ||
| Certified_Final_RTA_W911WN-17-B-8002.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
of Engineers
US Army Corps
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
AND APPROVAL OF ALL DRAWINGS LISTED ON THE INDEX SHEET.
SIGNATURES AFFIXED BELOW INDICATE OFFICIAL RECOMMENDATION
SUBMITTED BY:
SECTION CHIEF
APPROVAL RECOMMENDED BY:
BRANCH CHIEF
APPROVED BY:
CONSTRUCTION DIVISION
CHIEF, ENGINEERING AND
DATE
DATE
DATE
THEIR EMPLOYMENT AS REQUIRED BY ER 1110-1-8152.
APPEAR ON THESE PROJECT DOCUMENTS WITHIN THE SCOPE OF
DESIGNATIONS OF U.S. ARMY CORPS OF ENGINEERS INDIVIDUALS
THIS SHEET. THE INITIALS OR SIGNATURES AND REGISTRATION
U.S. ARMY CORPS OF ENGINEERS AND THE A/E FIRMS IDENTIFIED ON
THIS PROJECT WAS DESIGNED BY THE PITTSBURGH DISTRICT OF THE
Pittsburgh District
W911WN-17-B-8002
12 OCTOBER 2016
12 OCTOBER 2016
12 OCTOBER 2016
/s/ STEPHEN R. STOLTZ, P.E.
MONONGAHELA RIVER BASIN
BRADDOCK LOCKS AND DAM
DAM GATE CONTROL SYSTEM UPGRADE
G-0014
C O
V E
R S
H E
E T
CERTIFIED FINAL DOCUMENTS
/s/ JOHN E. NITES, P.E.
OCTOBER 2016
/s/ MOHAMMED F. IBRAHIM, P.E.
ALLEGHENY COUNTY, PA
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
®of Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G auto_username a u to s h o rt d e s ig n a u to s y ti m e auto_scale
P
IT
T S
B U
R G
H D
IS
T R
IC
T
W
W N -1
-B -8
A N
S I
D
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
M O
N O
N G
A H
E L
A R
IV
E R B
A S
IN
B R
A D
D O
C K L
O C
K S A
N D D
A M
D A
M G
A T
E C
O N
T R
O L S
Y S
T E
M U
P G
R A
R
G A
D O
M S
K I
C
M
IL
L E
R
O
C T
O B
E R
/s J
O H
N E
N
IT
E S P .E
D
N G
U Y
E N
CERTIFIED FINAL DOCUMENTS
INDEX DRAWINGSCONTRACT
NAMEFILE
SHEET
TITLEDRAWING
NO.ID
GENERAL
LBRO37_100_G-0014 G-0014 SHEETCOVER
LBRO37_204_G-1015 G-1015 LIMITS WORKCONTRACTOR
ELECTRICAL
LBRO37_429_E-1040 E-1040 PLAN LOCKSDOWNSTREAM
LBRO37_429_E-3041 E-3041 SECTIONS CROSSOVERDOWNSTREAM
LBRO37_429_E-4042 E-4042 PLANS FLOOR BUILDINGOPERATIONS
LBRO37_556_E-4043 E-4043 PLAN FLOOR 1 PIERDAM
LBRO37_556_E-4044 E-4044 PLAN FLOOR 4 & 2 PIERSDAM
LBRO37_556_E-4045 E-4045 PLAN FLOOR 3 PIERDAM
LBRO37_556_E-4046 E-4046 PLAN FLOOR 5 PIERDAM
LBRO37_556_E-6047 E-6047 ARCHITECTURE NETWORK PLCEXISTING
LBRO37_556_E-6048 E-6048 ARCHITECTURE NETWORK PLCNEW
BUILDING
OPERATIONS
CROSSOVER
BUILDING
ADMINISTRATIVE
BUILDING
EQUIPMENT
LAND WALL
MIDDLE WALL
BRIDGE
SERVICE
GATED DAM
10'-0" 10'-0"
10'-0"
RIVER WALL
FLOW
MONONGAHELA RIVER
N
ESPLANADE
CONTRACTOR WORK LIMITS
LEGEND:
120'0 60'
SCALE: 1"=60'
SCALE: 1"=60'
CONTRACTOR WORK LIMITS
PIER 1
PIER 2
PIER 3
PIER 4
PIER 5
G-1015
O
N T
R A
C T
O R W
O R
K L
IM
IT
S
O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
®of Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDCRM
L B
R O
G -1
.d g n
-O
C T -2
:1
0.083333:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
W
W N -1
-B -8
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
M O
N O
N G
A H
E L
A R
IV
E R B
A S
IN
B R
A D
D O
C K L
O C
K S A
N D D
A M
D A
M G
A T
E C
O N
T R
O L S
Y S
T E
M U
P G
R A
G A
D O
M S
K I
C
M
IL
L E
R
O
C T
O B
E R
/s J
O H
N E
N
IT
E S P .E
D
N G
U Y
E N
CROSSOVER
RIVER CHAMBER
BUILDING
OPERATIONS
CROSSOVER
LAND CHAMBER
CABLE CROSSING
EXISTING ELECTRICAL MANHOLE
TO CROSSOVER SHAFT
UNDERGROUND CONDUIT DUCTBANK
2" CONDUIT
EXISTING UNDERGROUND
OPTIC PATCH PANEL
NEW WALL MOUNTED FIBER
RIVER WALL
MIDDLE WALL
EQUIPMENT BUILDING
LAND WALL
LAND WALL
ESPLANADE
BUILDING
ADMINISTRATIVE
40'10'0 20'
SCALE: 1"=20'
SCALE: 1"=20'
DOWNSTREAM LOCKS PLAN
S T
A
.5
A
56'x360'
RIVER CHAMBER
110'x720'
LAND CHAMBER
FO1 FO2
A E-3041
FLOW
CONDUITS IN DROP CEILING
NEW CABLES IN EXISTING
E-1040
W N
S T
R E
A M L
O C
K S
P L
A N
NEW FIBER OPTIC CABLE
LEGEND:
IF PRESENT, IN THE LAND CHAMBER CROSSOVER.
USACE PROJECT PERSONNEL WILL PUMP OUT WATER,2.
ADMINISTRATIVE BUILDING.
ROUTE CABLES IN EXISTING CONDUITS RISERS ON SIDE OF1.
NOTES:
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
®of Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDCRM
L B
R O
E -1
.d g n
-O
C T -2
:1
0.083333:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
W
W N -1
-B -8
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
M O
N O
N G
A H
E L
A R
IV
E R B
A S
IN
B R
A D
D O
C K L
O C
K S A
N D D
A M
D A
M G
A T
E C
O N
T R
O L S
Y S
T E
M U
P G
R A
G A
D O
M S
K I
C
M
IL
L E
R
O
C T
O B
E R
/s J
O H
N E
N
IT
E S P .E
D
N G
U Y
E N
FO1 FO2
CONDUIT
UTILIZE AN AVAILABLE
GALLERY
RIVER WALL
CROSSOVER
RIVER CHAMBER
TO CROSSOVER SHAFT
UNDERGROUND CONDUIT DUCTBANK
CAN NOT BE USED
4 LOWER CONDUITS
CABLES NOT SHOWN
DUCTBANK, EXISTING
UNDERGROUND CONDUIT
GALLERY
LAND WALL
GALLERY
MIDDLE WALL
MIDDLE WALL
BUILDING
OPERATIONS
SHAFT
CROSSOVER
SHAFT
CROSSOVER
TO CROSSOVER SHAFT
UNDERGROUND CONDUIT DUCTBANK
MANHOLE
SHOWN FOR CLARITY)
(EQUIPMENT BUILDING NOT
ADMINISTRATIVE BUILDING
CROSSOVER
LAND CHAMBER
FLOOR
SLOT TO FIRST
ADMINISTRATIVE BUILDING
EXISTING 2" CONDUITS TO
FOR CONTINUATION
SEE DWG E-4042
FO1 FO2
FO1 FO2
B
ESPLANADE
EL. 691.75
CONDUITS
14-4" ELECTRICAL
PIPES
8-6" HYDRAULIC
FO1 FO2
FO1 FO2
A E-1040
SECTION
SCALE: „"=1'
NEW CHANNELS SHALL BE INSTALLED.
AND CLAMPS. IF EXISTING CHANNELS ARE NOT AVAILABLE,
CABLES SHALL BE SUPPORTED EVERY 3FT WITH CHANNELS2.
SUPPORTED EVERY 5FT DOWN THE SHAFT WITH CLAMPS.
TOP USING STAINLESS STEEL KELLUMS GRIPS AND
THE FIBER OPTIC CABLES SHALL BE SUPPORTED AT THE1.
NOTES:
8'0 4' 16'
SCALE: „"=1'
B
SECTION
SCALE: „"=1'
C
SECTION
SCALE: „"=1'
D
SECTION
SCALE: NTS
C
D
EL. 718.51
EL. 730.50
RIVER WALL
CULVERT
EL. 682.25
CABLE CROSSING
STA. 0+34.50A
EL. 718.51
FO1 FO2
EL. 681.25
CULVERT
EL. 718.50
EL. 706.58
EL. 725.00
EL. 730.50
LAND WALL
CULVERT
EL. 730.50
EL. 718.51
EL. 679.75
EL. 687.75
EL. 682.25
ADMINISTRATIVE BUILDING
EXISTING 2" CONDUITS ON
E-3041
O
W N
S T
R E
A M C
R O
S S
O V
E R
S E
C T
IO
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
®of Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDCRM
L B
R O
E -3
.d g n
-O
C T -2
:1
0.083333:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
W
W N -1
-B -8
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
M O
N O
N G
A H
E L
A R
IV
E R B
A S
IN
B R
A D
D O
C K L
O C
K S A
N D D
A M
D A
M G
A T
E C
O N
T R
O L S
Y S
T E
M U
P G
R A
G A
D O
M S
K I
C
M
IL
L E
R
O
C T
O B
E R
/s J
O H
N E
N
IT
E S P .E
D
N G
U Y
E N
CERTIFIED FINAL DOCUMENTS
NEW FIBER OPTIC CABLE
LEGEND:
GALLERY TO FIRST FLOOR
EXISTING 36"x6" SLOT FROM
SHAFT
CROSSOVER
DESKTOP PC
FURNISHED
GOVERNMENT
ABOVE
OPERATIONS BUILDING
FIRST FLOOR TO GALLERY
EXISTING 36"x6" SLOT FROM
WINSTED V8811, OR EQUAL
NEW 35" VERTICAL RACK CABINET,
EXISTING DVR
BOTTOM OF EQUIPMENT ROOM
PRO 1500 LOCATED IN
APC POWER SAVE BACK-UPS
IN CEILING, TYP
EXISTING CABLE TRAYS
FIRST FLOOR CABLE TRAY
EXISTING CONDUITS FROM
LAPTOP PC
GOVERNMENT FURNISHED
OR EQUAL, SEE DETAIL A
CABINET, WINSTED V8811,
NEW 35" VERTICAL RACK
OR EQUAL
WCH-04P, WALL MOUNTABLE,
NEW CORNING CABLE SYSTEMS
CS0
EXISTING
EXISTING MCC
BACK-UPS PRO 1500
APC POWER SAVING
IN EQUIPMENT RACK
MOUNTED ON SUBPANEL
TO BE REMOVED
EXISTING EQUIPMENT
MOTOR CONTROL CENTER
EXISTING CABLE TRAY ABOVE
N
C A
B L
O S
S O
V E
R
S T
A
.5
A
FO1 FO2
FO1 FO2
UP
DVR
UPS SWITCH
ETHERNET
STRATIX
A
DETAIL
SCALE: 1•"=1'
0 2' 4' 6'
SCALE: …"=1'
3 4
FO1 FO2
1' 2'0 6"
SCALE: 1•"=1'
SCALE: …"=1'
(AT OPERATIONS BUILDING)
GALLERY PLAN
SCALE: …"=1'
(OPERATIONS BUILDING)
FIRST FLOOR PLAN
SCALE: …"=1'
(OPERATIONS BUILDING)
SECOND FLOOR PLAN
E-4042
P
E R
A T
IO
N S B
U
IL
D
IN
G
F L
O O
R P
L A
ON THE SECOND FLOOR.
STRATIX ETHERNET SWITCH IN THE NEW EQUIPMENT RACK
UTILIZED FOR COMMUNICATIONS AND CONNECTED TO THE
A NEW CAT 6a COPPER ETHERNET CABLE SHALL BE
POWERED FROM A NEW UNINTERRUPTIBLE POWER SUPPLY.
THE GOVERNMENT FURNISHED DESKTOP PC SHALL BE5.
POWER SUPPLY IN THE NEW EQUIPMENT RACK.
PLUGGED INTO A 120VAC OUTLET ON THE UNINTERRUPTIBLE
ENGINEERING LAPTOP PC. THE LAPTOP PC SHALL BE
INSTALL NEW RSLOGIX STUDIO 5000 SOFTWARE ON4.
SWITCH VIA A CAT 6a COPPER ETHERNET CABLE.
SHALL BE CONNECTED TO THE NEW STRATIX ETHERNET
THE GOVERNMENT FURNISHED ENGINEERING LAPTOP PC3.
TO THE NEW EQUIPMENT RACK.
EXISTING DAM CONTROL STATION SHALL BE RELOCATED
THE EXISTING RACK MOUNTED VIDEO CONTROLLER IN THE2.
ENCLOSURE MOUNTED ON THE WALL.
BE TERMINATED TO A NEW FIBER OPTIC BREAKOUT
THE EXISTING FIBER OPTIC CABLES FROM THE DAM SHALL1.
NOTES:
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
®of Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDCRM
L B
R O
E -4
.d g n
-O
C T -2
:1
0.083333:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
W
W N -1
-B -8
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
M O
N O
N G
A H
E L
A R
IV
E R B
A S
IN
B R
A D
D O
C K L
O C
K S A
N D D
A M
D A
M G
A T
E C
O N
T R
O L S
Y S
T E
M U
P G
R A
G A
D O
M S
K I
C
M
IL
L E
R
O
C T
O B
E R
/s J
O H
N E
N
IT
E S P .E
D
N G
U Y
E N
CERTIFIED FINAL DOCUMENTS
DOWNUP
DOWNUP
ALONG CEILING
UTILIZE EXISTING CONDUITS
CEILING
ALONG
CONDUIT
EXISTING
NEW PLC ENCLOSURE
NEW (2) 1" CONDUITS
PIER 1 LEFT HPU
EXISTING GATE 1
OPTIC BREAKOUT
EXISTING FIBER
CONTROL STATION
EXISTING GATE #1 LOCAL
PANEL "DPP"
EXISTING POWER
PANEL "LP1"
EXISTING LIGHTING
ROOF DRAIN
EXISTING
PIPE TRENCH
EXISTING
N
CONFIGURATION.
SEE NEW PLC NETWORK ARCHITECTURE FOR HPU PLC5.
ENCLOSURE WITH FIBER OPTIC PATCH CABLES.
ETHERNET SWITCH TO EXISTING FIBER OPTIC BREAKOUT
EXISTING LOCAL CONTROL STATION. CONNECT NEW STRATIX
EXISTING FIBER OPTIC CABLES AND BREAKOUT ENCLOSURE IN4.
IN EXISTING CONDUIT.
1747-AENTR ETHERNET ADAPTER IN HPU REMOTE I/O RACK
INSTALL A NEW CAT 6a COPPER ETHERNET CABLE TO NEW
REMOVE EXISTING REMOTE I/O BLUE HOSE CABLE TO HPU AND3.
IN EACH NEW PLC ENCLOSURE.
A 100W PANEL HEATER WITH THERMOSTAT SHALL BE PROVIDED2.
UNISTRUT.
THE ENCLOSURE SHALL BE MOUNTED ON STAINLESS STEEL
DIMENSIONS FOR THE ENCLOSURE SHALL BE 24"Hx20"Wx8"D.
A HOFFMAN CONCEPT, TYPE 4X, CSD24208SS. MINIMUM
THE NEW PLC ENCLOSURE SHALL BE SIMILAR OR EQUAL TO1.
NOTES:
2' 4'0 1'
SCALE: •"=1'
E-4043
A
M P
IE
R
F L
O O
R P
L A
DAM PIER 1 FLOOR PLAN
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
®of Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDCRM
L B
R O
E -4
.d g n
-O
C T -2
:1
0.083333:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
W
W N -1
-B -8
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
M O
N O
N G
A H
E L
A R
IV
E R B
A S
IN
B R
A D
D O
C K L
O C
K S A
N D D
A M
D A
M G
A T
E C
O N
T R
O L S
Y S
T E
M U
P G
R A
G A
D O
M S
K I
C
M
IL
L E
R
O
C T
O B
E R
/s J
O H
N E
N
IT
E S P .E
D
N G
U Y
E N
CERTIFIED FINAL DOCUMENTS
DOWN
NEW PLC ENCLOSURE
NEW 2-1" CONDUIT
"LP2" ("LP4")
EXISTING LIGHTING PANEL
LEFT HPU)
(GATE 4 PIER 4
PIER 2 LEFT HPU
EXISTING GATE 2
CONTROL STATION
EXISTING GATE #2 (#4) LOCAL
(GATE 3 PIER 4 RIGHT HPU)
EXISTING GATE 1 PIER 2 RIGHT HPU
PIPE TRENCH
EXISTING
CONFIGURATION.
SEE NEW PLC NETWORK ARCHITECTURE FOR HPU PLC5.
ENCLOSURE WITH FIBER OPTIC PATCH CABLES.
ETHERNET SWITCH TO EXISTING FIBER OPTIC BREAKOUT
EXISTING LOCAL CONTROL STATION. CONNECT NEW STRATIX
EXISTING FIBER OPTIC CABLES AND BREAKOUT ENCLOSURE IN4.
IN EXISTING CONDUIT.
1747-AENTR ETHERNET ADAPTER IN HPU REMOTE I/O RACK
INSTALL A NEW CAT 6a COPPER ETHERNET CABLE TO NEW
REMOVE EXISTING REMOTE I/O BLUE HOSE CABLE TO HPU AND3.
IN EACH NEW PLC ENCLOSURE.
A 100W PANEL HEATER WITH THERMOSTAT SHALL BE PROVIDED2.
UNISTRUT.
THE ENCLOSURE SHALL BE MOUNTED ON STAINLESS STEEL
DIMENSIONS FOR THE ENCLOSURE SHALL BE 24"Hx20"Wx8"D.
A HOFFMAN CONCEPT, TYPE 4X, CSD24208SS. MINIMUM
THE NEW PLC ENCLOSURE SHALL BE SIMILAR OR EQUAL TO1.
NOTES:
2' 4'0 1'
SCALE: •"=1'
N
DAM PIERS 2 & 4 FLOOR PLAN
E-4044
A
M P
IE
R S
F L
O O
R P
L
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
®of Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDCRM
L B
R O
E -4
.d g n
-O
C T -2
:1
0.083333:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
W
W N -1
-B -8
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
M O
N O
N G
A H
E L
A R
IV
E R B
A S
IN
B R
A D
D O
C K L
O C
K S A
N D D
A M
D A
M G
A T
E C
O N
T R
O L S
Y S
T E
M U
P G
R A
G A
D O
M S
K I
C
M
IL
L E
R
O
C T
O B
E R
/s J
O H
N E
N
IT
E S P .E
D
N G
U Y
E N
NEW PLC ENCLOSURE
NEW 2-1" CONDUIT
RIGHT HPU
EXISTING GATE 2 PIER 3
PANEL "LP3"
EXISTING LIGHTING
CONTROL STATION
EXISTING GATE #3 LOCALPIER 3 LEFT HPU
EXISTING GATE 3
PIPE TRENCH
EXISTING
CONFIGURATION.
SEE NEW PLC NETWORK ARCHITECTURE FOR HPU PLC5.
ENCLOSURE WITH FIBER OPTIC PATCH CABLES.
ETHERNET SWITCH TO EXISTING FIBER OPTIC BREAKOUT
EXISTING LOCAL CONTROL STATION. CONNECT NEW STRATIX
EXISTING FIBER OPTIC CABLES AND BREAKOUT ENCLOSURE IN4.
IN EXISTING CONDUIT.
1747-AENTR ETHERNET ADAPTER IN HPU REMOTE I/O RACK
INSTALL A NEW CAT 6a COPPER ETHERNET CABLE TO NEW
REMOVE EXISTING REMOTE I/O BLUE HOSE CABLE TO HPU AND3.
IN EACH NEW PLC ENCLOSURE.
A 100W PANEL HEATER WITH THERMOSTAT SHALL BE PROVIDED2.
UNISTRUT.
THE ENCLOSURE SHALL BE MOUNTED ON STAINLESS STEEL
DIMENSIONS FOR THE ENCLOSURE SHALL BE 24"Hx20"Wx8"D.
A HOFFMAN CONCEPT, TYPE 4X, CSD24208SS. MINIMUM
THE NEW PLC ENCLOSURE SHALL BE SIMILAR OR EQUAL TO1.
NOTES:
2' 4'0 1'
SCALE: •"=1'
N
DAM PIER 3 FLOOR PLAN
E-4045
A
M P
IE
R
F L
O O
R P
L
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
®of Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDCRM
L B
R O
E -4
.d g n
-O
C T -2
:1
0.083333:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
W
W N -1
-B -8
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
M O
N O
N G
A H
E L
A R
IV
E R B
A S
IN
B R
A D
D O
C K L
O C
K S A
N D D
A M
D A
M G
A T
E C
O N
T R
O L S
Y S
T E
M U
P G
R A
G A
D O
M S
K I
C
M
IL
L E
R
O
C T
O B
E R
/s J
O H
N E
N
IT
E S P .E
D
N G
U Y
E N
RIGHT HPU
GATE 4 PIER 5
"LP5"
LIGHTING PANEL
PIPE TRENCH
CONFIGURATION.
SEE NEW PLC NETWORK ARCHITECTURE FOR HPU PLC1.
NOTES:
2' 4'0 1'
SCALE: •"=1'
N
DAM PIER 5 FLOOR PLAN
E-4046
A
M P
IE
R
F L
O O
R P
L
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
®of Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDCRM
L B
R O
E -4
.d g n
-O
C T -2
:1
0.083333:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
W
W N -1
-B -8
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
M O
N O
N G
A H
E L
A R
IV
E R B
A S
IN
B R
A D
D O
C K L
O C
K S A
N D D
A M
D A
M G
A T
E C
O N
T R
O L S
Y S
T E
M U
P G
R A
G A
D O
M S
K I
C
M
IL
L E
R
O
C T
O B
E R
/s J
O H
N E
N
IT
E S P .E
D
N G
U Y
E N
DATA INTERFACE MULTIMODE FIBER.
THE EXISTING FIBER OPTIC CABLES ARE 62.5/125 MICRON FIBER DISTRIBUTED5.
ARE NOT SHOWN FOR CLARITY.
FIBER OPTIC BREAKOUT ENCLOSURES IN THE RIGHT HYDRAULIC POWER UNITS (HPU)4.
TO THE NEW FIBER OPTIC BREAKOUT ENCLOSURE.
FIBER OPTIC CABLES SHALL BE REMOVED FROM THE ENCLOSURE AND RECONNECTED
OF THE MIDDLE WALL OPERATIONS BUILDING SHALL BE REMOVED. THE EXISTING
THE EXISTING FIBER OPTIC BREAKOUT ENCLOSURE ON THE SECOND FLOOR3.
EACH DAM GATE HYDRAULIC POWER UNIT AND DATALINER MESSAGE DISPLAY.
EACH DAM GATE PLC PROCESSOR COMMUNICATES VIA REMOTE I/O TO2.
BUILDING AND EACH DAM GATE PLC PROCESSOR.
DATA HIGHWAY PLUS NETWORK BETWEEN THE MIDDLE WALL OPERATIONS
THE EXISTING DAM GATE CONTROL PC COMMUNICATES VIA A FIBER OPTIC1.
NOTES:
GATE 1 - PIER #1
L
H
3 4
G G
5 6
FF
7 8
EB
A J M
PLC
D
J
3 4
G H
5 6
GF
7 8
FC
A J J
J
LEFT HPU
REMOTE I/O
GATE 1 - PIER #2
J
3 4
G H
5 6
GF
7 8
FC
A J D
J
REMOTE I/O
RIGHT HPU
GATE 2 - PIER #2
L
H
3 4
G G
5 6
FF
7 8
EB
A J M
PLC
D
J
3 4
G H
5 6
GF
7 8
FC
A J J
J
LEFT HPU
REMOTE I/O
GATE 2 - PIER #3
J
3 4
G H
5 6
GF
7 8
FC
A J D
J
REMOTE I/O
RIGHT HPU
GATE 3 - PIER #3
L
H
3 4
G G
5 6
FF
7 8
EB
A J M
PLC
D
J
3 4
G H
5 6
GF
7 8
FC
A J J
J
LEFT HPU
REMOTE I/O
GATE 3 - PIER #4
J
3 4
G H
5 6
GF
7 8
FC
A J D
J
REMOTE I/O
RIGHT HPU
GATE 4 - PIER #4
L
H
3 4
G G
5 6
FF
7 8
EB
A J M
PLC
D
J
3 4
G H
5 6
GF
7 8
FC
A J J
J
LEFT HPU
REMOTE I/O
GATE 4 - PIER #5
J
3 4
G H
5 6
GF
7 8
FC
A J D
J
REMOTE I/O
RIGHT HPU
GATE 1 LOCAL CONTROL STATION GATE 2 LOCAL CONTROL STATION GATE 3 LOCAL CONTROL STATION
GATE 4 LOCAL CONTROL STATION
OPERTAIONS BUILDING
MIDDLE WALL
SECOND FLOOR
ENCLOSURE
REMOTE CONTROL
SCALE: NTS
EXISTING PLC NETWORK ARCHITECTURE
DATA HIGHWAY+ FIBER OPTIC MODULEM.
DATALINERL.
FIBER OPTIC PATCH PANELK.
SPARE WITH COVERJ.
ANALOG INPUT/OUTPUT MODULEH.
DIGITAL OUTPUT MODULEG.
DIGITAL INPUT MODULEF.
REMOTE I/O SCANNERE.
REMOTE I/O FIBER OPTIC MODULED.
REMOTE I/O 1747-ASB ADAPTER MODULEC.
SLC 5/O4 PLC PROCESSORB.
POWER SUPPLYA.
KEY:
FIBER OPTIC DATA HIGHWAY+ NETWORK
K
M
K K K
K
A R
C H
IT
E C
T U
E-6047
X
IS
T
IN
G P
L C N
E T
W O
K
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
®of Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDCRM
L B
R O
E -6
.d g n
-O
C T -2
:1
0.083333:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
W
W N -1
-B -8
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
M O
N O
N G
A H
E L
A R
IV
E R B
A S
IN
B R
A D
D O
C K L
O C
K S A
N D D
A M
D A
M G
A T
E C
O N
T R
O L S
Y S
T E
M U
P G
R A
G A
D O
M S
K I
C
M
IL
L E
R
O
C T
O B
E R
/s J
O H
N E
N
IT
E S P .E
D
N G
U Y
E N
CERTIFIED FINAL DOCUMENTS
BLUE HOSE COPPER CABLE
FIBER OPTIC CABLE
LEGEND:
GATE 1 - PIER #1
L
H
3 4
G G
5 6
FF
7 8
JC
A J J
PLC
J
J
3 4
G H
5 6
GF
7 8
FC
A J J
J
LEFT HPU
REMOTE I/O
GATE 1 - PIER #2
J
3 4
G H
5 6
GF
7 8
FC
A J
J
REMOTE I/O
RIGHT HPU
GATE 2 - PIER #2
H
3 4
G G
5 6
FF
7 8
JC
A J
PLC
J
3 4
G H
5 6
GF
7 8
FC
A J J
J
LEFT HPU
REMOTE I/O
GATE 2 - PIER #3
J
3 4
G H
5 6
GF
7 8
FC
A J
J
REMOTE I/O
GATE 3 - PIER #3
H
3 4
G G
5 6
FF
7 8
JC
A J
PLC
J
3 4
G H
5 6
GF
7 8
FC
A J J
J
LEFT HPU
REMOTE I/O
GATE 3 - PIER #4
J
3 4
G H
5 6
GF
7 8
FC
A J
J
REMOTE I/O
GATE 4 - PIER #4
H
3 4
G G
5 6
FF
7 8
JC
A J
PLC
J
3 4
G H
5 6
GF
7 8
FC
A J J
J
LEFT HPU
REMOTE I/O
GATE 4 - PIER #5
J
3 4
G H
5 6
GF
7 8
FC
A J
J
REMOTE I/O
GATE 1 LOCAL CONTROL STATION GATE 2 LOCAL CONTROL STATION GATE 3 LOCAL CONTROL STATION
GATE 4 LOCAL CONTROL STATION
D D
L
D
L
D
L
BUILDING
ADMINISTRATION
LAND WALL
BUILDING
OPERATIONS
MIDDLE WALL
M
ENCLOSURE
NEW PLC
ENCLOSURE
NEW PLC
ENCLOSURE
NEW PLC
ENCLOSURE
NEW PLC
PC
LAPTOP
PC
DESKTOPPC
DESKTOP
SCALE: NTS
NEW PLC NETWORK ARCHITECTURE
N N
N
M
RIGHT HPU
M
RIGHT HPU
M
RIGHT HPU
M
JJ JJ
JJ
J J J
J
ETHERNET NETWORK
F01
F02
CAT6a COPPER ETHERNET CABLE
FIBER OPTIC CABLE
LEGEND:
NOTES:
EQUIPMENT MOUNTED IN THE NEW EQUIPMENT RACK.
SHALL BE PROVIDED BY THE CONTRACTOR FOR USE WITH THE LAPTOP PC AND OTHER
POWER SUPPLY SIMILAR OR EQUAL TO AN APC POWER SAVING BACK-UPS PRO 1500
FOR CONFIGURING FTVIEW SE AND FTVIEW ME TERMINALS. A NEW UNINTERRUPTIBLE
ONE LICENSED COPY OF RSLOGIX5000 AND ONE LICENSED COPY OF RSLOGIX STUDIO
STUDIO 5000 AND COMMUNICATIONS SOFTWARE. THE CONTRACTOR SHALL PROVIDE
THE GOVERNMENT FURNISHED LAPTOP PC SHALL BE CONFIGURED WITH RSLOGIX5000,12.
LOCKMASTER PRIOR TO RECONFIGURING THE CONTROL SYSTEM.
GIVEN TIME. THE CONTRACTOR SHALL COORDINATE THE OUTAGES WITH THE BRADDOCK
ONLY ONE DAM GATE CONTROL SYSTEM CAN BE TAKEN OUT OF SERVICE AT ANY11.
ARE NOT SHOWN FOR CLARITY.
FIBER OPTIC BREAKOUT ENCLOSURES IN THE RIGHT HYDRAULIC POWER UNITS (HPU)10.
ADAPTER PLATE MAY BE REQUIRED FOR MOUNTING.
SHALL BE MOUNTED IN THE SAME LOCATION AS THE EXISTING DATALINER. AN
COVERED WITH STAINLESS STEEL PLATING. THE NEW PANELVIEW PLUS 6 TERMINAL
LEFT CYLINDER DIGITAL DISPLAY SHALL BE REMOVED. UNUSED OPENINGS SHALL BE
BE DISPLAYED. ALL POWER AND SIGNAL WIRING TO THE DATALINER AND RIGHT AND
DATALINER. IN ADDITION, THE LEFT CYLINDER AND RIGHT CYLINDER POSITION SHALL
ALL SYSTEM MESSAGES AND ALARMS CURRENTLY DISPLAYED ON THE EXISTING
TERMINAL, 700 MODEL. THE NEW PANELVIEW PLUS 6 TERMINAL SHALL DISPLAY
EACH LOCAL CONTROL STATION SHALL BE REPLACED WITH A PANELVIEW PLUS 6
THE EXISTING DATALINER AND RIGHT AND LEFT CYLINDER DIGITAL DISPLAY IN9.
ALL EQUIPMENT AS SHOWN.
AND FIBER TO COPPER MEDIA CONVERTERS SHALL BE PROVIDED TO CONNECT
CONNECTION TO THE FIBER OPTIC BREAKOUT ENCLOSURES. ETHERNET CABLES
CONFIGURATION. FIBER OPTIC PATCH CABLES SHALL BE UTILIZED FOR
THE NEW STRATIX ETHERNET SWITCHES SHALL BE CONFIGURED IN A RING8.
BETTER THAN A ROCKWELL AUTOMATION 1769-L30ER.
AND 16 ETHERNET/IP NODES. THE PLC PROCESSOR SHALL BE EQUAL TO OR
USER MEMORY, DUAL PORT ETHERNET COMMUNICATIONS FOR RING TOPOLOGY,
THE NEW 1769 COMPACTLOGIX PROCESSOR SHALL HAVE A MINIMUM OF 1MB
EXISTING PROCESSORS TO THE NEW 1769 COMPACTLOGIX PLC PROCESSORS.
THE EXISTING SLC 500 PLC PROGRAMMING SHALL BE MIGRATED FROM THE7.
THERMOSTAT SHALL BE PROVIDED IN EACH NEW PLC ENCLOSURE.
ENCLOSURE VIA A NEW 1" CONDUIT. A 100 WATT PANEL HEATER WITH
NEW ENCLOSURE SHALL BE POWERED FROM 120VAC FROM THE EXISTING PLC
1769 COMPACTLOGIX PLC PROCESSOR AND A STRATIX ETHERNET SWITCH. THE
EACH LOCAL CONTROL STATION. THE NEW ENCLOSURE SHALL CONTAIN A NEW
A NEW HOFFMAN STAINLESS STEEL ENCLOSURE SHALL BE INSTALLED NEXT TO6.
SHALL BE REPLACED WITH A SLC 1747-AENTR ETHERNET ADAPTER.
REMOVED AND TURNED OVER TO THE GOVERNMENT. EACH REMOTE I/O ADAPTER
THE 1747-ASB REMOTE I/O ADAPTER IN EACH HPU REMOTE I/O RACK SHALL BE5.
COVERED WITH A BLANK PANEL COVER.
REMOVED AND TURNED OVER TO THE GOVERNMENT. THE EMPTY SLOT SHALL BE
THE REMOTE I/O SCANNER IN EACH LOCAL CONTROL ENCLOSURE SHALL BE4.
REPLACED WITH A SLC 1747-AENTR ETHERNET ADAPTER.
REMOVED AND TURNED OVER TO THE GOVERNMENT. EACH PROCESSOR SHALL BE
THE SLC 5/O4 PLC PROCESSOR IN EACH LOCAL CONTROL ENCLOSURE SHALL BE3.
I/O COMMUNICATIONS.
REMOVE ALL EXISTING BLUE HOSE CABLE FOR DATA HIGHWAY PLUS AND REMOTE2.
IN PLC RACKS SHALL BE COVERED WITH A BLANK PANEL COVER.
SHALL BE REMOVED AND TURNED OVER TO THE GOVERNMENT. EMPTY SLOTS
ENCLOSURE ON THE SECOND FLOOR OF THE MIDDLE WALL OPERATIONS BUILDING
STATIONS, THE HYDRAULIC POWER UNITS, AND IN THE REMOTE CONTROL
THE EXISTING PHOENIX DIGITAL FIBER OPTIC MODULES IN THE LOCAL CONTROL1.
ETHERNET SWITCHES AS REQUIRED FROM THE USACE CONTRACTING OFFICER'S REPRESENTATIVE.
THE CONTRACTOR SHALL OBTAIN ALL NECESSARY IP ADDRESSES FOR PLC'S, HMI'S, AND17.
BY ROCKWELL AUTOMATION AS A ROCKWELL AUTOMATION RECOGNIZED SYSTEMS INTEGRATOR.
SOFTWARE AND PLC UPGRADES SHALL SUBMIT EVIDENCE THEY ARE OFFICIALLY RECOGNIZED
SOFTWARE FOR AT LEAST THE PAST FIVE YEARS. THE CONTRACTOR PERFORMING THE
THEY HAVE WORKED WITH AND INSTALLED ROCKWELL AUTOMATION RSLOGIX5000 PROGRAMMING
THE CONTRACTOR'S QUALIFIED CONTROL SYSTEM INTEGRATOR SHALL PROVIDE EVIDENCE16.
FIBER DISTRIBUTED DATA INTERFACE MULTIMODE FIBER.
CONNECTOR HOUSING, WCH-04P. ALL NEW FIBER OPTIC CABLES SHALL BE 62.5/125 MICRON
ENCLOSURES SHALL SIMILAR OR EQUAL TO CORNING CABLE SYSTEMS WALL MOUNTABLE
MODULE IN EACH FIBER OPTIC BREAKOUT ENCLOSURE. THE FIBER OPTIC BREAKOUT
AND FIBER OPTIC CABLE 2 (FO2). ALL FIBERS SHALL BE CONNECTED TO A FIBER OPTIC
TERMINATE 24 FIBERS WITH ST STYLE CONNECTORS IN FIBER OPTIC CABLE 1 (FO1)15.
PROVIDED BY THE CONTRACTOR FOR USE WITH THE DESKTOP PC.
SIMILAR OR EQUAL TO AN APC POWER SAVING BACK-UPS PRO 1500 SHALL BE
IT ON THE LAND WALL DESKTOP PC. A NEW UNINTERRUPTIBLE POWER SUPPLY
THE CONTRACTOR SHALL PROVIDE ONE LICENSED COPY OF FTVIEW SE AND INSTALL
SHALL BE CONFIGURED AS A STANDALONE FTVIEW SE TERMINAL FOR OPERATING THE DAM.
THE GOVERNMENT FURNISHED DESKTOP PC IN THE LAND WALL ADMINISTRATION BUILDING14.
EQUIPMENT IN THE OFFICE.
PROVIDED BY THE CONTRACTOR FOR USE WITH THE DESKTOP PC AND OTHER
SIMILAR OR EQUAL TO AN APC POWER SAVING BACK-UPS PRO 1500 SHALL BE
INSTALLED ON THE NEW DESKTOP PC. A NEW UNINTERRUPTIBLE POWER SUPPLY
CURRENTLY INSTALLED ON THE EXISTING DAM CONTROL PC SHALL BE UPDATED AND
FTVIEW SE TERMINAL FOR OPERATING THE DAM. THE EXISTING FTVIEW SE LICENSE
THE DESKTOP PLC SHALL BE CONFIGURED AS A STANDALONEON THE FIRST FLOOR.
SHALL BE CONNECTED TO THE EXISTING KEYBOARD, MOUSE, AND MONITOR IN THE OFFICE
THE GOVERNMENT FURNISHED DESKTOP PC IN THE MIDDLE WALL OPERATIONS BUILDING13.
GOVERNMENT FURNISHED PC (NEW)N.
ETHERNET MEDIA CONVERTER (NEW)M.
PANELVIEW PLUS 6 TERMINAL (NEW)L.
FIBER OPTIC PATCH PANEL (NEW AND EXISTING)K.
SPARE WITH COVER (NEW AND EXISTING)J.
ANALOG INPUT/OUTPUT MODULE (EXISTING)H.
DIGITAL OUTPUT MODULE (EXISTING)G.
DIGITAL INPUT MODULE (EXISTING)F.
STRATIX MANAGED ETHERNET SWITCH (NEW)D.
ETHERNET MODULE 1747-AENTR (NEW)C.
COMPACTLOGIX PLC PROCESSOR (NEW)B.
POWER SUPPLY (EXISTING)A.
KEY:
K
D
K K K
K
K
B B B
B
A R
C H
IT
E C
T U
E-6048
E
W P
L C N
E T
W O
R K
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
®of Engineers
US Army Corps
1 2 3 4 5 6 7 8 9 10
F
IL
E N
A M
E
P L
O T D
A T
E
A
B
C
D
E
F
G
H4TSDCRM
L B
R O
E -6
.d g n
-O
C T -2
:1
0.083333:1
P
IT
T S
B U
R G
H D
IS
T R
IC
T
W
W N -1
-B -8
A N
S
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
M O
N O
N G
A H
E L
A R
IV
E R B
A S
IN
B R
A D
D O
C K L
O C
K S A
N D D
A M
D A
M G
A T
E C
O N
T R
O L S
Y S
T E
M U
P G
R A
G A
D O
M S
K I
C
M
IL
L E
R
O
C T
O B
E R
/s J
O H
N E
N
IT
E S P .E
D
N G
U Y
E
| LBRO37_100_G-0014 |
| LBRO37_204_G-1015 |
| LBRO37_429_E-1040 |
| LBRO37_429_E-3041 |
| LBRO37_429_E-4042 |
| LBRO37_556_E-4043 |
| LBRO37_556_E-4044 |
| LBRO37_556_E-4045 |
| LBRO37_556_E-4046 |
| LBRO37_556_E-6047 |
| LBRO37_556_E-6048 |
File details come from the government source that posted it. Updated .