Base

CONTRACTOR BID SCHEDULE

BASE YEAR FY18-FY19

HVAC IDIQ FY18-FY21

FORT MCCOY, WISCONSIN

Provide all labor, tools, equipment, materials, transportation, work, and supervision to replace or install new heating, ventilating, and air conditioning systems for various locations at Fort McCoy, Wisconsin in compliance with specifications and drawings. See Note at bottom of page.

BASE YEAR FY18-FY19

DESIGNATIONQUANTITYU/MUNIT PRICEAMOUNT
00012 ton air cooled condensing units including power, concrete pad with disconnect switch, and piping2EA$0.00
00023 ton air cooled condensing units including power, concrete pad with disconnect switch, and piping1EA$0.00
00034 ton air cooled condensing units including power, concrete pad with disconnect switch, and piping1EA$0.00
00045 ton air cooled condensing units including power, concrete pad with disconnect switch, and piping1EA$0.00
00052 ton evaporator cooling coil including cabinet, power, refrigerant & condensate piping, ductwork transitions & modifications2EA$0.00
00063 ton evaporator cooling coil including cabinet, power, refrigerant & condensate piping, ductwork transitions & modifications1EA$0.00
00074 ton evaporator cooling coil including cabinet, power, refrigerant & condensate piping, ductwork transitions & modifications1EA$0.00
00085 ton evaporator cooling coil including cabinet, power, refrigerant & condensate piping, ductwork transitions & modifications1EA$0.00
0009Replace motor and blower fan for existing furnace including power1EA$0.00
0010Ceiling suspension mount circulation fans (3 per maintenance bldg)1Bldg$0.00
0011External insulation on existing supply ductwork in building400SF$0.00
0012Remove and re-install T-bar ceilings to facilitate the insulation of supply ductwork500SF$0.00
0013Master programmable thermostat, room sensors & power complete for each cooling system5EA$0.00
0014Replace existing furnace with new 95% high efficiency or better, sealed combustion furnace unit2EA$0.00
0015Demolition of existing heating or cooling system and complete preparation for new system10EA$0.00
0016Single zone, 3/4 ton ductless split system air conditioner with one exterior condensing unit, one fan coil unit, concrete pad & disconnect switch, separate refrigerant lines piped to fan coil unit & power1EA$0.00
0017Single zone, 1 ton ductless split system air conditioner with one exterior condensing unit, one fan coil unit, concrete pad & disconnect switch, separate refrigerant lines piped to fan coil unit & power1EA$0.00
0018Single zone, 1-1/2 ton ductless split system air conditioner with one exterior condensing unit, one fan coil unit, concrete pad & disconnect switch, separate refrigerant lines piped to fan coil unit & power1EA$0.00
0019Single zone, 2 ton ductless split system air conditioner with one exterior condensing unit, one fan coil unit, concrete pad & disconnect switch, separate refrigerant lines piped to fan coil unit & power1EA$0.00
0020Single zone, 2-1/2 ton ductless split system air conditioner with one exterior condensing unit, one fan coil unit,concrete pad & disconnect switch, separate refrigerant lines piped to fan coil unit & power1EA$0.00
0021Multi zone, 1-1/2 ton ductless split system air conditioner with one exterior condensing unit, two fan coil units, concrete pad & disconnect switch, separate refrigerant lines piped to two fan coil units & power1EA$0.00
0022Multi zone, 2 ton ductless split system air conditioner with one exterior condensing unit, two fan coil units, concrete pad & disconnect switch, separate refrigerant lines piped to two fan coil units & power1EA$0.00
0023Multi zone, 2-1/2 ton ductless split system air conditioner with eone exterior condensing unit, four fan coil units, concrete pad & disconnect switch, separate refrigerant lines piped to four fan coil units & power1EA$0.00
0024Insulated spiral round galvanized ductwork, 6" to 10" diameter250LF$0.00
0025Louvered ceiing diffuser, 24" x 24" including installation in T-bar ceiling, balancing damper, and fittings40EA$0.00
00262 ton evaporator uncased coil with power, refrigerant & condensate piping, ductwork transitions & modifications, valves, fittings, and access panel1EA$0.00
00273 ton evaporator uncased coil with power, refrigerant & condensate piping, ductwork transitions & modifications, valves, fittings, and access panel1EA$0.00
00284 ton evaporator uncased coil with power, refrigerant & condensate piping, ductwork transitions & modifications, valves, fittings, and access panel1EA$0.00
00295 ton evaporator uncased coil with power, refrigerant & condensate piping, ductwork transitions & modifications, valves, fittings, and access panel1EA$0.00
0030Package Terminal Air Conditioning unit (PTAC, interior type) with exterior condensing unit including power, piping, rough ins, repair of finishes, connections and terminations2EA$0.00
0031Packaged HVAC unit (exterior type) including connections to existing gas piping & disconnect switch, new gas valve and regulator, new exterior rated duct insulation for exterior duct, and power2EA$0.00
0032Airflow testing, adjusting, and balancing (TAB) verification test for each new heating / cooling system serving a building (applies when there are not any modifications to existing ductwork) including balancing airflows to meet design airflow, adjusting furnace blower speed, and final TAB results. Minimum 2 tests for each new system.36Test$0.00
0033Complete TAB and duct air leakage testing (DALT) for each new heating / cooling system serving a building (applies when there are modifications to existing ductwork) including balancing airflows to meet design airflow, adjusting furnace blower speed, and final TAB and DALT reports. Minimum of 2 tests for each new system, 2 tests for each adjustable damper, and 2 tests per zone (each area with a separate thermostat).2EA$0.00
BID SCHEDULE (CLIN 0001) TOTAL$0.00

Note: Bidders must insert their values in Column G, the form will self fill and total the sheet.

Base Year Total (CLIN 0001)$0.00
Option 1 Total (CLIN 1001)$0.00
Option 2 Total (CLIN 2001)$0.00
Base + Option 1 + Option 2$0.00
FAR 52.217-6 30% Increase$0.00
Total Bid Price$0.00

Opt 1

CONTRACTOR BID SCHEDULE

OPTION YEAR 1 FY19-FY20

Provide all labor, tools, equipment, materials, transportation, work, and supervision to replace or install new heating, ventilating, and air conditioning systems for various locations at Fort McCoy, Wisconsin in compliance with specifications and drawings. See Note at bottom of page.

OPTION YEAR 1 FY19-FY20

DESIGNATIONQUANTITYU/MUNIT PRICEAMOUNT
00012 ton air cooled condensing units including power, concrete pad with disconnect switch, and piping2EA$0.00
00023 ton air cooled condensing units including power, concrete pad with disconnect switch, and piping1EA$0.00
00034 ton air cooled condensing units including power, concrete pad with disconnect switch, and piping1EA$0.00
00045 ton air cooled condensing units including power, concrete pad with disconnect switch, and piping1EA$0.00
00052 ton evaporator cooling coil including cabinet, power, refrigerant & condensate piping, ductwork transitions & modifications2EA$0.00
00063 ton evaporator cooling coil including cabinet, power, refrigerant & condensate piping, ductwork transitions & modifications1EA$0.00
00074 ton evaporator cooling coil including cabinet, power, refrigerant & condensate piping, ductwork transitions & modifications1EA$0.00
00085 ton evaporator cooling coil including cabinet, power, refrigerant & condensate piping, ductwork transitions & modifications1EA$0.00
0009Replace motor and blower fan for existing furnace including power1EA$0.00
0010Ceiling suspension mount circulation fans (3 per maintenance bldg)1Bldg$0.00
0011External insulation on existing supply ductwork in building400SF$0.00
0012Remove and re-install T-bar ceilings to facilitate the insulation of supply ductwork500SF$0.00
0013Master programmable thermostat, room sensors & power complete for each cooling system5EA$0.00
0014Replace existing furnace with new 95% high efficiency or better, sealed combustion furnace unit2EA$0.00
0015Demolition of existing heating or cooling system and complete preparation for new system10EA$0.00
0016Single zone, 3/4 ton ductless split system air conditioner with one exterior condensing unit, one fan coil unit, concrete pad & disconnect switch, separate refrigerant lines piped to fan coil unit & power1EA$0.00
0017Single zone, 1 ton ductless split system air conditioner with one exterior condensing unit, one fan coil unit, concrete pad & disconnect switch, separate refrigerant lines piped to fan coil unit & power1EA$0.00
0018Single zone, 1-1/2 ton ductless split system air conditioner with one exterior condensing unit, one fan coil unit, concrete pad & disconnect switch, separate refrigerant lines piped to fan coil unit & power1EA$0.00
0019Single zone, 2 ton ductless split system air conditioner with one exterior condensing unit, one fan coil unit, concrete pad & disconnect switch, separate refrigerant lines piped to fan coil unit & power1EA$0.00
0020Single zone, 2-1/2 ton ductless split system air conditioner with one exterior condensing unit, one fan coil unit,concrete pad & disconnect switch, separate refrigerant lines piped to fan coil unit & power1EA$0.00
0021Multi zone, 1-1/2 ton ductless split system air conditioner with one exterior condensing unit, two fan coil units, concrete pad & disconnect switch, separate refrigerant lines piped to two fan coil units & power1EA$0.00
0022Multi zone, 2 ton ductless split system air conditioner with one exterior condensing unit, two fan coil units, concrete pad & disconnect switch, separate refrigerant lines piped to two fan coil units & power1EA$0.00
0023Multi zone, 2-1/2 ton ductless split system air conditioner with eone exterior condensing unit, four fan coil units, concrete pad & disconnect switch, separate refrigerant lines piped to four fan coil units & power1EA$0.00
0024Insulated spiral round galvanized ductwork, 6" to 10" diameter250LF$0.00
0025Louvered ceiing diffuser, 24" x 24" including installation in T-bar ceiling, balancing damper, and fittings40EA$0.00
00262 ton evaporator uncased coil with power, refrigerant & condensate piping, ductwork transitions & modifications, valves, fittings, and access panel1EA$0.00
00273 ton evaporator uncased coil with power, refrigerant & condensate piping, ductwork transitions & modifications, valves, fittings, and access panel1EA$0.00
00284 ton evaporator uncased coil with power, refrigerant & condensate piping, ductwork transitions & modifications, valves, fittings, and access panel1EA$0.00
00295 ton evaporator uncased coil with power, refrigerant & condensate piping, ductwork transitions & modifications, valves, fittings, and access panel1EA$0.00
0030Package Terminal Air Conditioning unit (PTAC, interior type) with exterior condensing unit including power, piping, rough ins, repair of finishes, connections and terminations2EA$0.00
0031Packaged HVAC unit (exterior type) including connections to existing gas piping & disconnect switch, new gas valve and regulator, new exterior rated duct insulation for exterior duct, and power2EA$0.00
0032Airflow testing, adjusting, and balancing (TAB) verification test for each new heating / cooling system serving a building (applies when there are not any modifications to existing ductwork) including balancing airflows to meet design airflow, adjusting furnace blower speed, and final TAB results. Minimum 2 tests for each new system.36Test$0.00
0033Complete TAB and duct air leakage testing (DALT) for each new heating / cooling system serving a building (applies when there are modifications to existing ductwork) including balancing airflows to meet design airflow, adjusting furnace blower speed, and final TAB and DALT reports. Minimum of 2 tests for each new system, 2 tests for each adjustable damper, and 2 tests per zone (each area with a separate thermostat).2EA$0.00
BID SCHEDULE (CLIN 1001) TOTAL$0.00

Note: Bidders must insert their values in Column G, the form will self fill and total the sheet.

Opt 2

CONTRACTOR BID SCHEDULE

OPTION YEAR 2 FY20-FY21

Provide all labor, tools, equipment, materials, transportation, work, and supervision to replace or install new heating, ventilating, and air conditioning systems for various locations at Fort McCoy, Wisconsin in compliance with specifications and drawings. See Note at bottom of page.

OPTION YEAR 2 FY20-FY21

DESIGNATIONQUANTITYU/MUNIT PRICEAMOUNT
00012 ton air cooled condensing units including power, concrete pad with disconnect switch, and piping2EA$0.00
00023 ton air cooled condensing units including power, concrete pad with disconnect switch, and piping1EA$0.00
00034 ton air cooled condensing units including power, concrete pad with disconnect switch, and piping1EA$0.00
00045 ton air cooled condensing units including power, concrete pad with disconnect switch, and piping1EA$0.00
00052 ton evaporator cooling coil including cabinet, power, refrigerant & condensate piping, ductwork transitions & modifications2EA$0.00
00063 ton evaporator cooling coil including cabinet, power, refrigerant & condensate piping, ductwork transitions & modifications1EA$0.00
00074 ton evaporator cooling coil including cabinet, power, refrigerant & condensate piping, ductwork transitions & modifications1EA$0.00
00085 ton evaporator cooling coil including cabinet, power, refrigerant & condensate piping, ductwork transitions & modifications1EA$0.00
0009Replace motor and blower fan for existing furnace including power1EA$0.00
0010Ceiling suspension mount circulation fans (3 per maintenance bldg)1Bldg$0.00
0011External insulation on existing supply ductwork in building400SF$0.00
0012Remove and re-install T-bar ceilings to facilitate the insulation of supply ductwork500SF$0.00
0013Master programmable thermostat, room sensors & power complete for each cooling system5EA$0.00
0014Replace existing furnace with new 95% high efficiency or better, sealed combustion furnace unit2EA$0.00
0015Demolition of existing heating or cooling system and complete preparation for new system10EA$0.00
0016Single zone, 3/4 ton ductless split system air conditioner with one exterior condensing unit, one fan coil unit, concrete pad & disconnect switch, separate refrigerant lines piped to fan coil unit & power1EA$0.00
0017Single zone, 1 ton ductless split system air conditioner with one exterior condensing unit, one fan coil unit, concrete pad & disconnect switch, separate refrigerant lines piped to fan coil unit & power1EA$0.00
0018Single zone, 1-1/2 ton ductless split system air conditioner with one exterior condensing unit, one fan coil unit, concrete pad & disconnect switch, separate refrigerant lines piped to fan coil unit & power1EA$0.00
0019Single zone, 2 ton ductless split system air conditioner with one exterior condensing unit, one fan coil unit, concrete pad & disconnect switch, separate refrigerant lines piped to fan coil unit & power1EA$0.00
0020Single zone, 2-1/2 ton ductless split system air conditioner with one exterior condensing unit, one fan coil unit,concrete pad & disconnect switch, separate refrigerant lines piped to fan coil unit & power1EA$0.00
0021Multi zone, 1-1/2 ton ductless split system air conditioner with one exterior condensing unit, two fan coil units, concrete pad & disconnect switch, separate refrigerant lines piped to two fan coil units & power1EA$0.00
0022Multi zone, 2 ton ductless split system air conditioner with one exterior condensing unit, two fan coil units, concrete pad & disconnect switch, separate refrigerant lines piped to two fan coil units & power1EA$0.00
0023Multi zone, 2-1/2 ton ductless split system air conditioner with eone exterior condensing unit, four fan coil units, concrete pad & disconnect switch, separate refrigerant lines piped to four fan coil units & power1EA$0.00
0024Insulated spiral round galvanized ductwork, 6" to 10" diameter250LF$0.00
0025Louvered ceiing diffuser, 24" x 24" including installation in T-bar ceiling, balancing damper, and fittings40EA$0.00
00262 ton evaporator uncased coil with power, refrigerant & condensate piping, ductwork transitions & modifications, valves, fittings, and access panel1EA$0.00
00273 ton evaporator uncased coil with power, refrigerant & condensate piping, ductwork transitions & modifications, valves, fittings, and access panel1EA$0.00
00284 ton evaporator uncased coil with power, refrigerant & condensate piping, ductwork transitions & modifications, valves, fittings, and access panel1EA$0.00
00295 ton evaporator uncased coil with power, refrigerant & condensate piping, ductwork transitions & modifications, valves, fittings, and access panel1EA$0.00
0030Package Terminal Air Conditioning unit (PTAC, interior type) with exterior condensing unit including power, piping, rough ins, repair of finishes, connections and terminations2EA$0.00
0031Packaged HVAC unit (exterior type) including connections to existing gas piping & disconnect switch, new gas valve and regulator, new exterior rated duct insulation for exterior duct, and power2EA$0.00
0032Airflow testing, adjusting, and balancing (TAB) verification test for each new heating / cooling system serving a building (applies when there are not any modifications to existing ductwork) including balancing airflows to meet design airflow, adjusting furnace blower speed, and final TAB results. Minimum 2 tests for each new system.36Test$0.00
0033Complete TAB and duct air leakage testing (DALT) for each new heating / cooling system serving a building (applies when there are modifications to existing ductwork) including balancing airflows to meet design airflow, adjusting furnace blower speed, and final TAB and DALT reports. Minimum of 2 tests for each new system, 2 tests for each adjustable damper, and 2 tests per zone (each area with a separate thermostat).2EA$0.00
BID SCHEDULE (CLIN 2001) TOTAL$0.00

Note: Bidders must insert their values in Column G, the form will self fill and total the sheet.