W911SA-16-B-0008_Attachment_3_Drawings.pdf
PDF 1 MB Posted
- Attached to
- Repair Asphalt Roofing IDIQ
- Solicitation number
- W911SA16B0008
About this file
W911SA-16-B-0008 Attachment 3 - Drawings
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W911SA-16-B-0008_Bid_Abstract.pdf | ||
| W911SA-16-B-0008_Site_Visit_Sign_in_Sheet.pdf | ||
| W911SA-16-B-0008_Attachment_5_Wage_Rate_Requirements_Updated_6-20-16.docx | DOCX document | |
| W911SA-16-B-0008_Amendment_1.docx | DOCX document | |
| W911SA-16-B-0008_Attachment_4_Specifications.pdf | ||
| W911SA-16-B-0008_Attachment_6_SF24.pdf | ||
| W911SA-16-B-0008_Attachment_1_Bid_Schedule.xlsx | XLSX spreadsheet | |
| W911SA-16-B-0008_Final_Solicitation.docx | DOCX document | |
| W911SA-16-B-0008_Attachment_2_ATOPSEC_Coversheet.pdf | ||
| W911SA-16-B-0008_Attachment_5_Wage_Rate_Requirements.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL UTILITY NOTES
A. ANY UTILITIES AND STRUCTURES SHOWN ON PLAN DRAWINGS ARE
APPROXIMATE IN LOCATION AND DESCRIPTION AND ARE BASED ON
RECORDS AVAILABLE TO THE GOVERNMENT OR ON SURFACE FEATURES
INDICATING THEIR EXISTENCE. THERE MAY BE OTHER UTILITIES WITHIN
THE PROJECT AREA WHICH ARE NOT SHOWN. THE LACK OF UTILITIES ON
PLAN DRAWINGS IS NOT AN INDICATION OF A UTILITY-FREE PROJECT SITE.
B. NOTIFY ALL AFFECTED UTILITY COMPANIES OF CONSTRUCTION
OPERATIONS AT LEAST THREE WORKING DAYS BEFORE BEGINNING WORK
NEAR THEIR FACILITIES. DO NOT BEGIN EXCAVATION WORK UNTIL
UNDERGROUND UTILITY LOCATIONS HAVE BEEN MARKED OR THE UTILITY
COMPANY HAS SENT NOTICE THAT THE AREA IS CLEAR.
C. SCALES SHOWN ONLY APPLY WHEN THESE DRAWINGS ARE PRINTED
ON 22" x 34" PAPER. SCALES ARE HALF SIZED WHEN PRINTED ON 11" x 17"
PAPER.
Fort McCoy, Wisconsin
SHEET INDEX:
G0.1
ROOFING IDIQ CONTRACT
FY 17 - FY 20
G0.1 - COVER SHEET
A7.1 - FLASHING DETAILS
A7.2 - FLASHING DETAILS
A7.3 - VENTILATION DETAIL
A7.1
NOT TO SCALE
GABLE WALL
A7.1
NOT TO SCALE
WALL FLASHING
A7.1
NOT TO SCALE
CHIMNEY SECTION
A7.1
2 GABLE WALL
5 WALL FLASHING
A7.2
NOT TO SCALE
WALL FLASHING
A7.2
NOT TO SCALE
END WALL FLASHING
WALL FLASHING
A7.2
4 END WALL FLASHING
PATCH AND REPAIR EXISTING ROOF DECK AS NEEDED.
NEW SHINGLES AND
UNDERLAYMENT (TYP.)
PATCH AND REPAIR EXISTING ROOF DECK AS NEEDED.
NEW SHINGLES AND
UNDERLAYMENT (TYP.)
ICE DAM MEMBRANE
66" FROM D-EDGE
(TYP.)
ICE DAM MEMBRANE
66" FROM D-EDGE
(TYP.)
INSTALL NEW RIDGE VENT
NEW GUTTER, DOWNSPOUT
AND SPLASH BLOCK
NEW GUTTER, DOWNSPOUT
AND SPLASH BLOCK
NEW GUTTER, DOWNSPOUT
AND SPLASH BLOCK
NEW GUTTER, DOWNSPOUT
AND SPLASH BLOCK
A7.3
A7.3
NOT TO SCALE
VENTILATION DETAIL CLIN OO2A, H & I
A7.3
NOT TO SCALE
FASTENER DETAIL CLIN OO1U, 2A & 2B
A7.3
NOT TO SCALE
ROOF DETAIL
File details come from the government source that posted it. Updated .