GOVERNMENT ESTIMATE
BASE YEAR FY16 - FY17
MUNICIPAL WATER MAIN IDIQ CONTRACT
FORT MCCOY, WISCONSIN
BID SCHEDULE
Furnish all labor, tools, equipment, materials, transportation, and supervision to replace or repair water mains and laterals.
| DESIGNATION | QUANTITY | U/M | UNIT PRICE | AMOUNT | |
| 0001 | Install 6" water main | 1500 | LF | 0.00 | 0.00 |
| 0002 | Install 8" water main | 3000 | LF | 0.00 | 0.00 |
| 0003 | Install 10" water main | 3000 | LF | 0.00 | 0.00 |
| 0004 | Install 12" water main | 4000 | LF | 0.00 | 0.00 |
| 0005 | Install 16" water main | 200 | LF | 0.00 | 0.00 |
| 0006 | Remove hydrants | 50 | EA | 0.00 | 0.00 |
| 0007 | Install new hydrants | 15 | EA | 0.00 | 0.00 |
| 0008 | Install fire hydrant riser extensions | 10 | EA | 0.00 | 0.00 |
| 0009 | Removal of concrete | 100 | SY | 0.00 | 0.00 |
| 0010 | Install concrete | 100 | SY | 0.00 | 0.00 |
| 0011 | Removal of asphalt pavement | 500 | SY | 0.00 | 0.00 |
| 0012 | Installation of asphalt pavement | 500 | SY | 0.00 | 0.00 |
| 0013 | Remove and replace with concrete culvert up to 24" | 350 | LF | 0.00 | 0.00 |
| 0014 | Remove and replace with steel culvert up to 16" | 250 | LF | 0.00 | 0.00 |
| 0015 | Remove and replace with PVC culvert up to 12" | 100 | LF | 0.00 | 0.00 |
| 0016 | Install base coarse material | 350 | CY | 0.00 | 0.00 |
| 0017 | Remove and replace manhole | 5 | EA | 0.00 | 0.00 |
| 0018 | Horizontal boring, 2" thru 6" pipe sizes | 500 | LF | 0.00 | 0.00 |
| 0019 | Horizontal boring, 8" thru 12" pipe sizes | 500 | LF | 0.00 | 0.00 |
| 0020 | Remove Gate valves | 200 | EA | 0.00 | 0.00 |
| 0021 | Install 4-inch Gate valve | 10 | EA | 0.00 | 0.00 |
| 0022 | Install 6-inch Gate valve | 50 | EA | 0.00 | 0.00 |
| 0023 | Install 8-inch Gate Valve | 40 | EA | 0.00 | 0.00 |
| 0024 | Install 10-inch Gate Valve | 30 | EA | 0.00 | 0.00 |
| 0025 | Install 12-inch Gate valve | 20 | EA | 0.00 | 0.00 |
| 0026 | Install 16-inch Gate valve | 5 | EA | 0.00 | 0.00 |
| 0027 | Install 4-inch post indicator valve | 5 | EA | 0.00 | 0.00 |
| 0028 | Install 2-inch lateral | 750 | LF | 0.00 | 0.00 |
| 0029 | Install 4-inch lateral | 400 | LF | 0.00 | 0.00 |
| 0030 | Install 2 inch Tap | 150 | EA | 0.00 | 0.00 |
| 0031 | Install tee fitting, sizes from 4"x 4" thru 8" x 4" | 20 | EA | 0.00 | 0.00 |
| 0032 | Install tee fitting, sizes from 10"x 4" thru 12" x 4" | 20 | EA | 0.00 | 0.00 |
| 0033 | Install tee fitting, sizes from 6"x 6" thru 8" x 6" | 100 | EA | 0.00 | 0.00 |
| 0034 | Install tee fitting, sizes from 10"x 6" thru 12" x 6" | 75 | EA | 0.00 | 0.00 |
| 0035 | Install tee fitting, sizes from 8"x 8" thru 12" x 8" | 75 | EA | 0.00 | 0.00 |
| 0036 | Install tee fitting, sizes from 10"x 10" thru 12" x 12" | 75 | EA | 0.00 | 0.00 |
| 0037 | Install tee fitting, sizes from 16"x 8" thru 16" x 16" | 5 | EA | 0.00 | 0.00 |
| 0038 | Install repair coupling, 2" | 50 | EA | 0.00 | 0.00 |
| 0039 | Install repair coupling, 4" thru 6" | 100 | EA | 0.00 | 0.00 |
| 0040 | Install repair coupling, 8" thru 12" | 150 | EA | 0.00 | 0.00 |
| 0041 | Install 90 degree fitting, 2" | 20 | EA | 0.00 | 0.00 |
| 0042 | Install 90 degree fitting, 4" thru 6" | 50 | EA | 0.00 | 0.00 |
| 0043 | Install 90 degree fitting, 8" thru 12" | 50 | EA | 0.00 | 0.00 |
| 0044 | Install 90 degree fitting, 16" | 2 | EA | 0.00 | 0.00 |
| 0045 | Install 45 degree fitting, 4" thru 6" | 100 | EA | 0.00 | 0.00 |
| 0046 | Install 45 degree fitting, 8" thru 12" | 100 | EA | 0.00 | 0.00 |
| 0047 | Install 45 degree fitting, 16" | 2 | EA | 0.00 | 0.00 |
| 0048 | Install 22.5 degree fitting, 4" thru 6" | 20 | EA | 0.00 | 0.00 |
| 0049 | Install 22.5 degree fitting, 8" thru 12" | 20 | EA | 0.00 | 0.00 |
| 0050 | Install 22.5 degree fitting, 16" | 2 | EA | 0.00 | 0.00 |
| 0051 | Install reducer fitting, sizes from 6"x 4" thru 8" x 4" | 20 | EA | 0.00 | 0.00 |
| 0052 | Install reducer fitting, sizes from 10"x4" thru 12"x 4" | 20 | EA | 0.00 | 0.00 |
| 0053 | Install reducer fitting, sizes from 8"x 6" thru 12" x 6" | 50 | EA | 0.00 | 0.00 |
| 0054 | Install reducer fitting, sizes from 10"x8" thru 12"x 8" | 50 | EA | 0.00 | 0.00 |
| 0055 | Install reducer fitting, sizes from 12"x10" thru 16"x10" | 20 | EA | 0.00 | 0.00 |
| 0056 | Install reducer fitting, 16"x12" | 2 | EA | 0.00 | 0.00 |
| 0057 | Install cross fitting, sizes from 2" thru 6" | 30 | EA | 0.00 | 0.00 |
| 0058 | Install cross fitting, sizes from 8" thru 12" | 15 | EA | 0.00 | 0.00 |
| 0059 | Install cap or plug fitting, 3/4" thru 3" | 50 | EA | 0.00 | 0.00 |
| 0060 | Install cap or plug fitting, 4" thru 12" | 50 | EA | 0.00 | 0.00 |
| 0061 | Removal of chain link fence | 200 | LF | 0.00 | 0.00 |
| 0062 | Installation of chain link fence | 200 | LF | 0.00 | 0.00 |
| 0063 | Remove abandoned ≤ 6" water line | 3000 | LF | 0.00 | 0.00 |
| 0064 | Remove abandoned > 6" water line | 5000 | LF | 0.00 | 0.00 |
| 0065 | Remove abandoned manhole | 10 | EA | 0.00 | 0.00 |
| TOTAL | 0.00 | ||||
| Bidder can input item quantity and cost and the form will self-fill. | |||||
| Base Year | 0.00 | ||||
| Option Year 1 | 0.00 | ||||
| Option Year 2 | 0.00 | ||||
| 6 Month Extention | 0 | ||||
| Total | 0.00 |
Opt 1
GOVERNMENT ESTIMATE
OPTION YEAR 1 FY17-FY18
MUNICIPAL WATER MAIN IDIQ CONTRACT
FORT MCCOY, WISCONSIN
Furnish all labor, tools, equipment, materials, transportation, and supervision to replace or repair water mains and laterals.
| DESIGNATION | QUANTITY | U/M | UNIT PRICE | AMOUNT | |
| 1001 | Install 6" water main | 1500 | LF | 0.00 | 0.00 |
| 1002 | Install 8" water main | 3000 | LF | 0.00 | 0.00 |
| 1003 | Install 10" water main | 3000 | LF | 0.00 | 0.00 |
| 1004 | Install 12" water main | 4000 | LF | 0.00 | 0.00 |
| 1005 | Install 16" water main | 200 | LF | 0.00 | 0.00 |
| 1006 | Remove hydrants | 50 | EA | 0.00 | 0.00 |
| 1007 | Install new hydrants | 15 | EA | 0.00 | 0.00 |
| 1008 | Install fire hydrant riser extensions | 10 | EA | 0.00 | 0.00 |
| 1009 | Removal of concrete | 100 | SY | 0.00 | 0.00 |
| 1010 | Install concrete | 100 | SY | 0.00 | 0.00 |
| 1011 | Removal of asphalt pavement | 500 | SY | 0.00 | 0.00 |
| 1012 | Installation of asphalt pavement | 500 | SY | 0.00 | 0.00 |
| 1013 | Remove and replace with concrete culvert up to 24" | 350 | LF | 0.00 | 0.00 |
| 1014 | Remove and replace with steel culvert up to 16" | 250 | LF | 0.00 | 0.00 |
| 1015 | Remove and replace with PVC culvert up to 12" | 100 | LF | 0.00 | 0.00 |
| 1016 | Install base coarse material | 350 | CY | 0.00 | 0.00 |
| 1017 | Remove and replace manhole | 5 | EA | 0.00 | 0.00 |
| 1018 | Horizontal boring, 2" thru 6" pipe sizes | 500 | LF | 0.00 | 0.00 |
| 1019 | Horizontal boring, 8" thru 12" pipe sizes | 500 | LF | 0.00 | 0.00 |
| 1020 | Remove Gate valves | 200 | EA | 0.00 | 0.00 |
| 1021 | Install 4-inch Gate valve | 10 | EA | 0.00 | 0.00 |
| 1022 | Install 6-inch Gate valve | 50 | EA | 0.00 | 0.00 |
| 1023 | Install 8-inch Gate Valve | 40 | EA | 0.00 | 0.00 |
| 1024 | Install 10-inch Gate Valve | 30 | EA | 0.00 | 0.00 |
| 1025 | Install 12-inch Gate valve | 20 | EA | 0.00 | 0.00 |
| 1026 | Install 16-inch Gate valve | 5 | EA | 0.00 | 0.00 |
| 1027 | Install 4-inch post indicator valve | 5 | EA | 0.00 | 0.00 |
| 1028 | Install 2-inch lateral | 750 | LF | 0.00 | 0.00 |
| 1029 | Install 4-inch lateral | 400 | LF | 0.00 | 0.00 |
| 1030 | Install 2 inch Tap | 150 | EA | 0.00 | 0.00 |
| 1031 | Install tee fitting, sizes from 4"x 4" thru 8" x 4" | 20 | EA | 0.00 | 0.00 |
| 1032 | Install tee fitting, sizes from 10"x 4" thru 12" x 4" | 20 | EA | 0.00 | 0.00 |
| 1033 | Install tee fitting, sizes from 6"x 6" thru 8" x 6" | 100 | EA | 0.00 | 0.00 |
| 1034 | Install tee fitting, sizes from 10"x 6" thru 12" x 6" | 75 | EA | 0.00 | 0.00 |
| 1035 | Install tee fitting, sizes from 8"x 8" thru 12" x 8" | 75 | EA | 0.00 | 0.00 |
| 1036 | Install tee fitting, sizes from 10"x 10" thru 12" x 12" | 75 | EA | 0.00 | 0.00 |
| 1037 | Install tee fitting, sizes from 16"x 8" thru 16" x 16" | 5 | EA | 0.00 | 0.00 |
| 1038 | Install repair coupling, 2" | 50 | EA | 0.00 | 0.00 |
| 1039 | Install repair coupling, 4" thru 6" | 100 | EA | 0.00 | 0.00 |
| 1040 | Install repair coupling, 8" thru 12" | 150 | EA | 0.00 | 0.00 |
| 1041 | Install 90 degree fitting, 2" | 20 | EA | 0.00 | 0.00 |
| 1042 | Install 90 degree fitting, 4" thru 6" | 50 | EA | 0.00 | 0.00 |
| 1043 | Install 90 degree fitting, 8" thru 12" | 50 | EA | 0.00 | 0.00 |
| 1044 | Install 90 degree fitting, 16" | 2 | EA | 0.00 | 0.00 |
| 1045 | Install 45 degree fitting, 4" thru 6" | 100 | EA | 0.00 | 0.00 |
| 1046 | Install 45 degree fitting, 8" thru 12" | 100 | EA | 0.00 | 0.00 |
| 1047 | Install 45 degree fitting, 16" | 2 | EA | 0.00 | 0.00 |
| 1048 | Install 22.5 degree fitting, 4" thru 6" | 20 | EA | 0.00 | 0.00 |
| 1049 | Install 22.5 degree fitting, 8" thru 12" | 20 | EA | 0.00 | 0.00 |
| 1050 | Install 22.5 degree fitting, 16" | 2 | EA | 0.00 | 0.00 |
| 1051 | Install reducer fitting, sizes from 6"x 4" thru 8" x 4" | 20 | EA | 0.00 | 0.00 |
| 1052 | Install reducer fitting, sizes from 10"x4" thru 12"x 4" | 20 | EA | 0.00 | 0.00 |
| 1053 | Install reducer fitting, sizes from 8"x 6" thru 12" x 6" | 50 | EA | 0.00 | 0.00 |
| 1054 | Install reducer fitting, sizes from 10"x8" thru 12"x 8" | 50 | EA | 0.00 | 0.00 |
| 1055 | Install reducer fitting, sizes from 12"x10" thru 16"x10" | 20 | EA | 0.00 | 0.00 |
| 1056 | Install reducer fitting, 16"x12" | 2 | EA | 0.00 | 0.00 |
| 1057 | Install cross fitting, sizes from 2" thru 6" | 30 | EA | 0.00 | 0.00 |
| 1058 | Install cross fitting, sizes from 8" thru 12" | 15 | EA | 0.00 | 0.00 |
| 1059 | Install cap or plug fitting, 3/4" thru 3" | 50 | EA | 0.00 | 0.00 |
| 1060 | Install cap or plug fitting, 4" thru 12" | 50 | EA | 0.00 | 0.00 |
| 1061 | Removal of chain link fence | 200 | LF | 0.00 | 0.00 |
| 1062 | Installation of chain link fence | 200 | LF | 0.00 | 0.00 |
| 0063 | Remove abandoned ≤ 6" water line | 3000 | LF | 0.00 | 0.00 |
| 0064 | Remove abandoned > 6" water line | 5000 | LF | 0.00 | 0.00 |
| 0065 | Remove abandoned manhole | 10 | EA | 0.00 | 0.00 |
| TOTAL | 0.00 | ||||
| Bidder can input item quantity and cost and the form will self-fill. |
Opt 2
GOVERNMENT ESTIMATE
OPTION YEAR 2 FY18-FY19
MUNICIPAL WATER MAIN IDIQ CONTRACT
FORT MCCOY, WISCONSIN
Furnish all labor, tools, equipment, materials, transportation, and supervision to replace or repair water mains and laterals.
| DESIGNATION | QUANTITY | U/M | UNIT PRICE | AMOUNT | |
| 2001 | Install 6" water main | 1500 | LF | 0.00 | 0.00 |
| 2002 | Install 8" water main | 3000 | LF | 0.00 | 0.00 |
| 2003 | Install 10" water main | 3000 | LF | 0.00 | 0.00 |
| 2004 | Install 12" water main | 4000 | LF | 0.00 | 0.00 |
| 2005 | Install 16" water main | 200 | LF | 0.00 | 0.00 |
| 2006 | Remove hydrants | 50 | EA | 0.00 | 0.00 |
| 2007 | Install new hydrants | 15 | EA | 0.00 | 0.00 |
| 2008 | Install fire hydrant riser extensions | 10 | EA | 0.00 | 0.00 |
| 2009 | Removal of concrete | 100 | SY | 0.00 | 0.00 |
| 2010 | Install concrete | 100 | SY | 0.00 | 0.00 |
| 2011 | Removal of asphalt pavement | 500 | SY | 0.00 | 0.00 |
| 2012 | Installation of asphalt pavement | 500 | SY | 0.00 | 0.00 |
| 2013 | Remove and replace with concrete culvert up to 24" | 350 | LF | 0.00 | 0.00 |
| 2014 | Remove and replace with steel culvert up to 16" | 250 | LF | 0.00 | 0.00 |
| 2015 | Remove and replace with PVC culvert up to 12" | 100 | LF | 0.00 | 0.00 |
| 2016 | Install base coarse material | 350 | CY | 0.00 | 0.00 |
| 2017 | Remove and replace manhole | 5 | EA | 0.00 | 0.00 |
| 2018 | Horizontal boring, 2" thru 6" pipe sizes | 500 | LF | 0.00 | 0.00 |
| 2019 | Horizontal boring, 8" thru 12" pipe sizes | 500 | LF | 0.00 | 0.00 |
| 2020 | Remove Gate valves | 200 | EA | 0.00 | 0.00 |
| 2021 | Install 4-inch Gate valve | 10 | EA | 0.00 | 0.00 |
| 2022 | Install 6-inch Gate valve | 50 | EA | 0.00 | 0.00 |
| 2023 | Install 8-inch Gate Valve | 40 | EA | 0.00 | 0.00 |
| 2024 | Install 10-inch Gate Valve | 30 | EA | 0.00 | 0.00 |
| 2025 | Install 12-inch Gate valve | 20 | EA | 0.00 | 0.00 |
| 2026 | Install 16-inch Gate valve | 5 | EA | 0.00 | 0.00 |
| 2027 | Install 4-inch post indicator valve | 5 | EA | 0.00 | 0.00 |
| 2028 | Install 2-inch lateral | 750 | LF | 0.00 | 0.00 |
| 2029 | Install 4-inch lateral | 400 | LF | 0.00 | 0.00 |
| 2030 | Install 2 inch Tap | 150 | EA | 0.00 | 0.00 |
| 2031 | Install tee fitting, sizes from 4"x 4" thru 8" x 4" | 20 | EA | 0.00 | 0.00 |
| 2032 | Install tee fitting, sizes from 10"x 4" thru 12" x 4" | 20 | EA | 0.00 | 0.00 |
| 2033 | Install tee fitting, sizes from 6"x 6" thru 8" x 6" | 100 | EA | 0.00 | 0.00 |
| 2034 | Install tee fitting, sizes from 10"x 6" thru 12" x 6" | 75 | EA | 0.00 | 0.00 |
| 2035 | Install tee fitting, sizes from 8"x 8" thru 12" x 8" | 75 | EA | 0.00 | 0.00 |
| 2036 | Install tee fitting, sizes from 10"x 10" thru 12" x 12" | 75 | EA | 0.00 | 0.00 |
| 2037 | Install tee fitting, sizes from 16"x 8" thru 16" x 16" | 5 | EA | 0.00 | 0.00 |
| 2038 | Install repair coupling, 2" | 50 | EA | 0.00 | 0.00 |
| 2039 | Install repair coupling, 4" thru 6" | 100 | EA | 0.00 | 0.00 |
| 2040 | Install repair coupling, 8" thru 12" | 150 | EA | 0.00 | 0.00 |
| 2041 | Install 90 degree fitting, 2" | 20 | EA | 0.00 | 0.00 |
| 2042 | Install 90 degree fitting, 4" thru 6" | 50 | EA | 0.00 | 0.00 |
| 2043 | Install 90 degree fitting, 8" thru 12" | 50 | EA | 0.00 | 0.00 |
| 2044 | Install 90 degree fitting, 16" | 2 | EA | 0.00 | 0.00 |
| 2045 | Install 45 degree fitting, 4" thru 6" | 100 | EA | 0.00 | 0.00 |
| 2046 | Install 45 degree fitting, 8" thru 12" | 100 | EA | 0.00 | 0.00 |
| 2047 | Install 45 degree fitting, 16" | 2 | EA | 0.00 | 0.00 |
| 2048 | Install 22.5 degree fitting, 4" thru 6" | 20 | EA | 0.00 | 0.00 |
| 2049 | Install 22.5 degree fitting, 8" thru 12" | 20 | EA | 0.00 | 0.00 |
| 2050 | Install 22.5 degree fitting, 16" | 2 | EA | 0.00 | 0.00 |
| 2051 | Install reducer fitting, sizes from 6"x 4" thru 8" x 4" | 20 | EA | 0.00 | 0.00 |
| 2052 | Install reducer fitting, sizes from 10"x4" thru 12"x 4" | 20 | EA | 0.00 | 0.00 |
| 2053 | Install reducer fitting, sizes from 8"x 6" thru 12" x 6" | 50 | EA | 0.00 | 0.00 |
| 2054 | Install reducer fitting, sizes from 10"x8" thru 12"x 8" | 50 | EA | 0.00 | 0.00 |
| 2055 | Install reducer fitting, sizes from 12"x10" thru 16"x10" | 20 | EA | 0.00 | 0.00 |
| 2056 | Install reducer fitting, 16"x12" | 2 | EA | 0.00 | 0.00 |
| 2057 | Install cross fitting, sizes from 2" thru 6" | 30 | EA | 0.00 | 0.00 |
| 2058 | Install cross fitting, sizes from 8" thru 12" | 15 | EA | 0.00 | 0.00 |
| 2059 | Install cap or plug fitting, 3/4" thru 3" | 50 | EA | 0.00 | 0.00 |
| 2060 | Install cap or plug fitting, 4" thru 12" | 50 | EA | 0.00 | 0.00 |
| 2061 | Removal of chain link fence | 200 | LF | 0.00 | 0.00 |
| 2062 | Installation of chain link fence | 200 | LF | 0.00 | 0.00 |
| 0063 | Remove abandoned ≤ 6" water line | 3000 | LF | 0.00 | 0.00 |
| 0064 | Remove abandoned > 6" water line | 5000 | LF | 0.00 | 0.00 |
| 0065 | Remove abandoned manhole | 10 | EA | 0.00 | 0.00 |
| TOTAL | 0.00 | ||||