Revised Drawing C3 of 7
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W911S7-16-B-0016_Abstract_of_Offers.pdf | ||
| Questions_and_Answers _UCS_at_TA79 _final.pdf | ||
| 8028_a2v8REV.pdf | ||
| 8028_a3v8REV.pdf | ||
| 8028_c2v8.pdf | ||
| W911S7-16-B-0016-0001_UCS_at_TA_79 _UCS_at_TA79 _Amendment.pdf | ||
| DBA_Wage_Determination _19_August_2016.pdf | ||
| 8028_a1v8REV.pdf | ||
| W911S7-16-B-0016_Sign-In_Sheet_17_Aug_2016.pdf | ||
| W911S7-16-B-0016_UCS_at_TA_79_Solicitation _Final.pdf | ||
| DBA_Wage_Determination_MO160019_29_July_2016.pdf | ||
| Attachment_A _SOW_16-B-0016__Final.pdf | ||
| Attachment_B _Drawings_16-B-0016.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
L O
U
IS
IA
N A
V
E
N
TA 79
0 10 10 20FT
SCALE: 1''= 10'
MOVE TO NEW LOCATION
EXISTING TANK.
N E
W
G
S
I
X I
S T I
N E x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
NEW TA 79 WAREHOUSE
PROJECT NO:
DRAWING NO:
SHEET OF
DATE
SCALE
D E
S I
G N
E D
D R
A W
N
C H
E C
K E
D
S U
B M I
T T
E D
A P
P R
O V
E D
D A
T E
D P
W F
O R
T
O N
A
D
O
M
S S
O U
R I
D A
T E
D E
S C
R I
P T I
O N
M A
D E
A P
P R
D
R E
V I
S I
O N
S
L v
O f
D I
R E
C T
O R
A
F
P U
B L
C
R K
S
C O
O R
D I
N A
T I
O N
D A
T E
D A
T E
D A
T E
ˆ" = 1'
B
S H
S H
S H
J
L E
S
14 OCT 15
C.0004528
HDC 03268-5J
C3
G
B E
R
E N
G
PP
PP
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
MIN. 10 FT FROM THE FENCE
NEW TANK LOCATION
TURF
TA 79 WAREHOUSE
TA 79 WAREHOUSE
BLDG 2136
TURF
ASPHALT PAVEMENT
ASPHALT PAVEMENT
ELECTRIC S
ERVICE
TURF
C U
T T
E R
LINE UNDER IMPROVEMENTS.
AFTER THE VALVE. REMOVE
WATER VALVE. CAP 3" LINE
U T I
L I
Y
P
A N
SEE ELECTRICAL PLAN
POLE T.B.M.
E X I S
T I
N E
OUTSIDE OF THE FENCE
GUY TO BE MOVED
C900 CLASS 235.
NEW 6" WATER LINE
T.B.M. OUTSIDE OF FENCE.
EXISTING TANK AND 6 BOLLARDS
SEE DETAILS SHT C6.
INSTALL CONCRETE BLOCKING.
TAPPING SLEEVE AND VALVE.
WATER LINE SHALL HAVE A
INVERT 94.72
TO ELEV. 99.14
EXISTING MANHOLE
COLLAR (TYP)
W/ CONCRETE
6" CLEAN-OUT
NOTES:
ADDITIONAL TANK FOR NEW BLDG.
FORM THE FENCE. PROVIDE ONE
NEW TANK LOCATION MIN 10 FT
xxxx x x x x x
TURF
SEWER MANHOLE
S E
W
N E
T Y P
BOTH SIDES OF BLDG. DETAIL 15 SHT C7
CONNECT ALL BLDG DOWNSPOUTS ON
6" SDR 35 SOLID DRAIN PIPE.
TO DAYLIGHT
110 FT. OF 6" SOLID SDR 35 DRAIN PIPE
GUY
THRUST BLOCK
TELECOMMUNICATION POLETP
POWER POLEPP
TEMPORARY CONTROL POINTT.C.P.
TO BE REMOVEDT.B.R.
TO BE MOVEDT.B.M.
SHEETSHT
O.C.E.W-ON CENTER EACH WAY
FEETFT.
ELEVATIONELEV.
BUILDINGBLDG
CURB AND GUTTER
EDGE OF HARD SURFACE/ROAD
NEW FENCE
EXISTING FENCE
NEW WATER
EXISTING WATER
NEW SEWER
EXISTING SEWER
NEW GAS LINE
EXISTING GAS LINE
LEGEND
THE POST SPACED 4FT APART.
PLACE 10 BOLLARDS AROUND
MIN. 40 FT FROM THE BLDG.
NEW POST INDICATOR VALVE
SPECIFICATIONS. FINAL GRADES TO MATCH GRADING PLAN SHT C4.
10. ALL TURF AREAS DISTURBED BY THE CONTRACTOR, EXCEPT AS NOTED, SHALL BE SEEDED AND MULCHED ACCORDING TO
INVERT TO PROVIDE A SMOOTH PLASTERED SURFACE FOR PROPERLY CHANNELED DRAINAGE FROM THE NEW CONNECTION.
FLUSHED WITH THE INNER WALL SURFACE EXCEPT AS INDICATED. PROVIDE NECESSARY MODIFICATIONS TO THE EXISTING
PIPE SHALL BE SOLIDLY FILLED WITH MORTAR, AND NEATLY POINTED UP ON THE INSIDE TO PRESENT A SMOOTH JOINT, WHICH SHALL BE COMPLETELY COATED WITH MORTAR BEFORE SETTING THE PIPE, AFTER SETTING, ALL SPACES AROUND THE
TO AVOID UNNECESSARY DAMAGE TO THE MASONRY. ALL LOOSE MATERIAL SHALL BE REMOVED FROM THE CUT SURFACES, SPACE AROUND THE PIPE FOR BEDDING AND FILLING SOLIDLY WITH 1-3 CEMENT-SAND MORTAR. CARE SHALL BE USED
9. MANHOLE CONNECTION: A HOLE SHALL BE CUT IN THE MANHOLE WALL TO PERMIT INSERTING THE PIPE WITH 2" OF
EXCAVATIONS WHILE WORK IS NOT IN PROGRESS.
8. CONTRACTOR SHALL SUPPLY AND MAINTAIN HIGH VISIBILITY FENCING, FOUR FOOT HIGH, AROUND ALL OPEN TRENCHES OR
MAINTENANCE.
SEWER/WATER PIPES. THE THRUST BLOCKS SHALL BE PLACED SO AS TO ALLOW REMOVAL OF MECHANICAL JOINTS FOR FUTURE
7. CONCRETE THRUST BLOCKS SHALL BE PLACED ON THE OUTER SIDE OF ALL BENDS AND AT ALL CONNECTIONS IN
REPRESENTATIVE.
CONTRACTOR SHALL ENSURE ALL TRACER WIRE PASSES A CURRENT. RESULTS OF TESTS SHALL BE PROVIDED TO CONTRACTING
SNAKE PIT BY COPPERHEAD OR APPROVED EQUAL. AFTER INSTALLATION CURRENT SHALL BE PASSED THROUGH TRACER WIRE.
3 FEET INTO THE GROUND AND HAVE A CONCRETE COLLAR LOCATED AT FINISH GRADE. PROVIDE MAGNETIZED TRACER STATION, MINIMUM OF 3 FEET OF TRACER WIRE SHALL BE COILED INSIDE THE TRACER STATION. THE PIPE SHALL EXTEND AT LEAST
WITHIN 10 FEET OF ENTRY INTO BUILDINGS. TRACER STATIONS SHALL BE CONSTRUCTED OF 4 INCH PVC SCH 40 PIPE.
6. TRACER STATIONS SHALL BE INSTALLED ON ALL UTILITIES THAT REQUIRE TRACER WIRE AT TEES, VALVES, HYDRANTS, CIRCUIT AND TEST UNTIL TRACER WIRE WORKS IN ACCORDANCE WITH ITS INTENDED USE.
DEMONSTRATE THAT THE WIRE IS CAPABLE OF LOCATING THE PIPE. IF WIRE WILL NOT PASS CURRENT, LOCATE BREAK IN
STRAPS SUCH THAT WIRE REMAINS IN PLACE DURING EMBEDDING OF PIPE. CURRENT IS TO BE PASSED THROUGH THE WIRE TO
SECURE THE TRACER WIRE TO THE TOP OF THE PIPE, MINIMUM EVERY FIVE FEET WITH ADHESIVE TAPE OR PLASTIC TIE
TRACER WIRE SHALL RUN THE FULL LENGTH OF THE UTILITY LINE AND SHALL BE TERMINATED AT THE BUILDING AND DEAD-ENDS.
AFFIXED TO THE PIPE, AND EXTENDED UP AT RISERS AND EXPOSED IN VALVE BOXES, UTILITY STRUCTURES, ETC. THE
5. ALL UNDERGROUND NON-FERROUS WATER/SEWER PIPE SHALL HAVE NO. 12 AWG INSULATED COPPER TRACER WIRES PERMANENTLY
BEAR A CONTINUOUS PRINTED INSCRIPTION DESCRIBING THE UTILITY LINE.
MARKING AND LOCATING UNDERGROUND UTILITIES. TAPE COLOR TO BE GREEN FOR SEWER AND BLUE FOR WATER AND SHALL
OF 1750 PSI LENGTHWISE AND 1500 PSI CROSSWISE. THE TAPE SHALL BE OF A TYPE SPECIFICALLY MANUFACTURED FOR
POLYETHYLENE FILM, 6-INCHES WIDE WITH MINIMUM THICKNESS OF 0.004 INCH. TAPE SHALL HAVE A MINIMUM STRENGTH
BELOW FINISHED GRADE FOR THE FULL LENGTH OF THE LINE. PLASTIC MARKING TAPE SHALL BE ACID AND ALKALI-RESISTANT
4. PLASTIC MARKING TAPE SHALL BE INSTALLED DIRECTLY ABOVE THE UTILITY LINES. THE TAPE SHALL BE PLACED 12"
CONTRACTOR.
3. MECHANICAL JOINT FITTINGS SHALL BE USED AT ALL TURNS IN SEWER/WATER PIPES. FITTINGS SHALL BE PROVIDED BY
SHALL BE CAST IRON 514 I.D. THE VALVE BOX SHALL BE INCASED IN 8"X8"X18" CONCRETE.
THE EXISTING LINE. GATE VALVE SHALL BE MUELLER A 2361-20 WITH MECHANICAL JTS OR APPROVED EQUAL. VALVE BOXES
2. CONTRACTOR SHALL PROVIDE RESILIENT WEDGE GATE VALVE AND VALVE BOX WITHIN SIX FEET OF THE CONNECTION WITH
FOR AT LEAST 2 FULL DAYS.
STATE APPROVED METHODS. DISINFECTION PROCEDURES SHALL CONTINUE UNTIL TEST INDICATED THE ABSENCE OF POLLUTION
LEAST 1 WATER SAMPLE IN PROPER STERILIZED CONTAINERS AND PERFORM A BACTERIAL EXAMINATION IN ACCORDANCE WITH
THE RESIDUAL CHLORINE IS REDUCED TO LESS THAN 1 PPM. CONTRACTOR'S STATE CERTIFIED LABORATORY SHALL TAKE AT
25 PPM OF FREE CHLORINE RESIDUAL AT THE END OF THAT TIME. THE LINE SHALL BE FLUSHED WITH CLEAN WATER UNTIL
DOSAGE OF NOT LESS THAN 50 PPM. DETENTION TIME SHALL BE AT LEAST 24 HOURS AND SHALL PRODUCE A MINIMUM OF
THOROUGHLY FLUSHED PRIOR TO THE INTRODUCTION OF A SOLUTION OF CHLORINATING MATERIAL WHICH WILL PROVIDE A
BE REPEATED UNTIL TEST RESULTS ARE SATISFACTORY. COMPLETED WATERLINE SHALL BE DISINFECTED. WATERLINE SHALL BE
PRESSURE. DEFECTIVE MATERIALS AND JOINTS SHOWING LEAKAGE SHALL BE REPLACED OR REMADE AS NECESSARY. TEST SHALL
FOR ONE HOUR TO A HYDROSTATIC PRESSURE TEST AT 135 PSI., BUT NO LESS THAN ONE AND A HALF TIMES THE SYSTEM
TO PREVENT PIPE FROM BENDING OUT OF TRENCH, LEAVING THE JOINTS EXPOSED. THE WATER LINE SHALL BE SUBJECTED
SHALL BE BEDDED IN SAND. FOR THE FULL WIDTH AND LENGTH OF THE PIPE. AFTER THE TRENCH IS PARTIALLY BACKFILLED
BE INCASED IN 4" OF CONCRETE ALL AROUND FOR MIN. 10' OF THE INTERSECTION EACH WAY. WATER AND SEWER LINES
AT THE INTERSECTION OF SEWER AND WATER, WATER LINE SHALL BE ABOVE SEWER LINE MINIMUM 18". SEWER LINE SHALL
1. WATER/SEWER LINES SHALL BE MINIMUM 42" BELOW FINISHED GRADE. SEWER LINE SHALL HAVE UNIFORM SLOPE.
C8028.33
S U I T
E
(U
C S
C O
N S
T R
U
I F I
M M
A
HYDRANT
NEW FIRE
CONNECT TO EXISTING MANHOLE
NEW 4" SCH 40 PVC SEWER PIPE
M B
R E
V I
S
8028_c1v8.dgn Default 8/26/2016 3:23:55 PM