8028_a3v8REV.pdf

PDF 247 KB Posted

Attached to
Construct Unified Command Suite (UCS) at TA 79 Federal contract opportunity
Solicitation number
W911S7-16-B-0016
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command Fort Leonard Wood

About this file

Revised Drawing A3 of 3

View the file

Other files for this federal contract opportunity

Other files attached to Construct Unified Command Suite (UCS) at TA 79, newest first.
File Type Posted
W911S7-16-B-0016_Abstract_of_Offers.pdf PDF
Questions_and_Answers _UCS_at_TA79 _final.pdf PDF
8028_c2v8.pdf PDF
W911S7-16-B-0016-0001_UCS_at_TA_79 _UCS_at_TA79 _Amendment.pdf PDF
8028_a2v8REV.pdf PDF
8028_c3v8.pdf PDF
DBA_Wage_Determination _19_August_2016.pdf PDF
8028_a1v8REV.pdf PDF
W911S7-16-B-0016_Sign-In_Sheet_17_Aug_2016.pdf PDF
W911S7-16-B-0016_UCS_at_TA_79_Solicitation _Final.pdf PDF
DBA_Wage_Determination_MO160019_29_July_2016.pdf PDF
Attachment_A _SOW_16-B-0016__Final.pdf PDF
Attachment_B _Drawings_16-B-0016.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCALE: ‚" = 1'0"

TYPICAL DOORS

A

EXTERIOR DOORS TO BE 18 GAUGE AND GALVANIZED WITH FACTORY PRIMER

SECTION

SEE SPECIFICATION SECTION 08700 FOR HARDWARE SCHEDULE

WITH ELECTRIC AND BACK UP CHAIN HOIST OPERATION

UPWARD ACTING SIMILAR TO OVERHEAD DOOR CO. THERMACORE

INSULATED OVERHEAD DOORS SHALL BE EXTRA HEAVY DUTY .016" STEEL

EXTERIOR FRAMES TO BE GALVANIZED WITH FACTORY PRIMER

DOOR FRAMES TO BE HEAVY DUTY STEEL 16 GA

B C

L v

O f

EQUIVALENCY BASED ON VINYL DOOR SEAL AND INTEGRAL RAIN DRIP

SIMILAR TO DORBIN 103DV DARK BROWN ANODIZED FINISH OR EQUAL

ON EXTERIOR DOORS PROVIDE DOOR BOTTOM WITH INTEGRAL RAIN DRIP

SECTION NOTES:

PROVIDE 30# FELT AT SLAB/PIER JUNCTION

SLAB/GRADE BEAM JUNCTION

PROVIDE •" EXPANSION JOINT MATERIAL AT

PROVIDE SEALED CONCRETE FLOOR IN MECHANICAL ROOM

PROVIDE NONSLIP SURFACE

OR APPROVED EQUAL ON CONCRETE FLOOR

PROVIDE 2 COATS OF CRYSTAL SEAL OTC BY DAYTON SUPERIOR

PRIOR TO APPLICATION OF CONCRETE SEALERS

SLAB SHALL BE CLEAN AND CLEAR OF OILS AND OTHER DELETERIOUS MATERIALS

REMARKS

DOOR SCHEDULE

NO.

ROOM NO.

FROM TO

DOOR

TYPE DOOR FRAME

MATERIAL HW

NO.

DOOR SIZE

101 EXT 1 METAL METAL

EXT METAL METAL

METAL

METAL METAL

METAL

METAL

METAL

DETAILS

HEAD

JAMB

SILL

2-3'0" X 7'0" X 1ƒ"

A

A

3'0" X 7'0" X 1ƒ"

3'0" X 7'0" X 1ƒ"

EXT METAL

METAL

METAL

3'0" X 7'0" X 1ƒ"

EXT 101

PROVIDE „" X 4" VINYL BASE AT ALL WALLS

MECHEXT

METAL

METAL

METAL 3

SECTIONAL OVERHEAD DOOR

14'0" X 16'0" INSULATED METAL

C

D

B

LAMINATED GLASS

1" INSULATED

DOOR STOP PLAN DETAIL

SCALE: •" = 1'0"

105 DEGREES - 9•" FROM PERPENDICULAR 90 DEGREE LINE AS SHOWN.

NO POST SHALL BE SET TO ALLOW DOOR TO SWING MORE THAN

CLOSER CATCHES. DOOR SWING VARIES FROM 90 -105 DEGREES

STRIKE STEEL POST SLIGHTLY BEFORE OR AT THE SAME TIME DOOR

SWING OCCURS (LIMITED BY THE DOOR CLOSERS). DOOR MUST

STEEL POST SHELL BE SET AT POINT WHERE MAXIMUM DOOR

8"

GALVANIZED DOOR

FLUSH STEEL INSULATED

3'0" X 7'0"

WITH 3" X 33" GLASS PANEL

GALVANIZED DOOR

FLUSH STEEL INSULATED

3'0" X 7'0"

D

3'0" X 7'0" X 1ƒ" 102

EXT

EXT

14'0" X 16'0" GAR DR

AND TWO FINISH COATS OF GLOSS LATEX ENAMEL

PAINT ALL METAL DOORS AND FRAMES WITH ONE COAT OF PRIMER

14'0" X 16'0" GAR DR

14'0" X 16'0" GAR DR

SCALE: ‚" = 1'0"

24 4 8 16 FT

A P

P R

D M

A D

E

D I

R E

C T

O R

A T

E

O F

P U

B L I

C

W

R K

S

F O

R

L

O N

A

D

W

O

M I

S S

O U

R I

D E

S C

R I

P T I

O N

R E

V I

S I

O N

S

D A

T E

G A

Y

B E

R

S

E D

B

A P

P R

O V

E D

D A

T E

S U

B M I

T T

E D

C H

E C

K E

D

D R

A W

N

D E

S I

G N

E D

C O

O R

D I

N A

T I

O N

D A

T E

D A

T E

D A

T E

SCALE

DATE

PROJECT NO:

DRAWING NO:

OFSHEET

AS SHOWN

A3 3

S E

C T I

N

T A I

L

E L

L E

E L

L E

E L

L E

G

B E

R T

S

C8028.33

GALVANIZED DOORS

FLUSH STEEL INSULATED

DOUBLE 3'0" X 7'0"

2B

METAL EXT 101 METALD14'0" X 16'0" GAR DR 4

D

D

109 102 CORR

METAL METAL 3'0" X 7'0" X 1ƒ" B 6102 103

METAL METAL 3'0" X 7'0" X 1ƒ" A 7CORR 101

METAL METAL 3'0" X 7'0" X 1ƒ" B 8CORR MEN

METAL METAL 3'0" X 7'0" X 1ƒ" B 9CORR JAN

METAL METAL 3'0" X 7'0" X 1ƒ" B 10CORR WOM

INTERIOR METAL PANELS SHALL HAVE SMOOTH OR CORRICATED SURFACE

REFER TO CIVIL

TO STORM SEWER

RUN DOWNSPOUTS INTO SLEEVE

DOOR NOTES:

BE AWARE OF LIGHTS ABOVE AND ADJUST LIGHTS AS NEEDED

OVERHEAD DOOR WILL SLIDE INTO A VERTICAL POSITION

12" X 12" GRILLE

VINYL FACED

INSULATION

R-30 BATT

INSULATION

R-19 BATT

INSULATION

2" RIGID

AWAY FROM BUILDING

SLOPE FINISH GRADE

BEYOND

COLUMN FOUNDATION

& 3" SQ DS

METAL CANOPY

SIZE AND LOCATION

MECHANICAL FOR RADIANT HEAT

REFER TO

SIZE AND LOCATION

MECHANICAL FOR RADIANT HEAT

REFER TO

REFER TO ELECTRICAL

CABLE TRAY

110 109

VERTICAL LIFT POSITION

OVERHEAD DOOR IN

45 MIN. FIRE DR.

45 MIN. FIRE DR.

IN GP ROOM, RESTROOM, AND COMSEC ROOM

OF 2•" METAL STUDS W/ †" TYPE "X" GYPSUM BOARD

EXTERIOR WALLS AND COLUMN FURRING SHALL BE

REFER TO ELECTRICAL

PENDENT MOUNTED LIGHTS

ALSO PROVIDE MINIMUM 50 STC RATING FOR DOOR 110

DOORS 109 AND 110 ARE 45 MINUTE FIRE RATED DOORS

C.0004528

METAL METALEXT 10'0" X 10'0" GAR DR115 EXISTING 4 B2136 ON THE EAST END

DOOR ADDED TO EXISTING

SECTIONAL OVERHEAD DOOR

10'0" X 10'0" INSULATED METAL

E

E

1 2

A

D

B

FE

FE

REFER TO SITE PLAN FOR ACTUAL NORTH

PLAN NORTH

N O

R T

H

SCALE: „" = 1'0"

SCALE: „" = 1'0"

24 4 8 16 FT

SCALE: ‚" = 1'0"

DOOR 115 NOTES:

PROVIDE FENCE TO MATCH IN NEW LOCATION

REMOVE GATE AND FENCE TO EXTENT SHOWN

MOVE FIRE EXTINGUISHER TO NEW LOCATION

REMOVE LINER PANEL AS NEEDED TO PROVIDE FRAMING

ELECTRICAL PANEL

FLOOR PLAN EXISTING B2136

REFER TO CIVIL FOR FLATWORK

MATCH EXISTING DOOR OPENER IN BUILDING AS TO ELECTRICAL FEATURES

FROM SPARE CIRCUIT BREAKER, PHOTO EYE AND PUSHBUTTON STATION

FOR NEW DOOR OPENER, PROVIDE 240 VOLT, 30 AMP NEMA 1 SAFETY SWITCH, DEDICATED 20 AMP, 120 VOLT CIRCUIT

FAN CIRCUIT CURRENTLY UTILIZES A 15 AMP CIRCUIT BREAKER

IF CONTRACTOR PLANS TO USE REMAINING PORTION OF FAN CIRCUIT

IN CONJUNCTION WITH MECHANICAL WORK, REMOVE EXISTING FAN CIRCUIT BACK TO LOCATION OF NEW DOOR OPENER

CONDUIT AND CONDUCTORS BACK TO BOX TO REMAIN.

IN CONJUNCTION WITH ARCHITECTURAL WORK, REMOVE EXISTING RECEPTACLE, BOX(ES),

S U I

T E

U C

C O

N S

T R

U

I

F I

M M

A N

D

FENCE AND GATE

REMOVE EXISTING

NEW FENCE LOCATION

USE EXISTING DUCT AND BUILDING PENETRATION WHERE POSSIBLE.

PROVIDE DUCTWORK AS REQUIRED TO ROUTE COMBUSTION AIR TO INFRARED TUBE HEATER AROUND NEW OVERHEAD DOOR.

IN CONJUNCTION WITH ARCHITECTURAL WORK, REMOVE EXISTING EXHAUST FAN LOCATED ON THE EAST WALL COMPLETE.

WEIGHT 300 LBS

SIZE AND LOCATION

MECHANICAL FOR EXHAUST SYSTEM

REFER TO

14 OCT 15

G

D

Q

2016-08-30T11:05:40-0500
ROBERTS.GARY.L.1231307644

File details come from the government source that posted it. Updated .