20170830_-_VCC-Revised_dwgs.pdf

PDF 9 MB Posted

Attached to
Construct Visitor Control Center, Fort Drum, NY Federal contract opportunity
Solicitation number
W911S2-17-B-0001
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command Fort Drum

About this file

Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Construct Visitor Control Center, Fort Drum, NY, newest first.
File Type Posted
20170907_-_W911S2-17-B-0001-0003.pdf PDF
20170509_-_Appx_3.2_Revised_VCC_Narrative_Final_Design_For_Construction.pdf PDF
20170830_-_RFIs_VCC_HE-00001-5J.pdf PDF
20170830_-_W911S2-17-B-0001-0002.pdf PDF
20170810_-_W911S2-17-B-0001-0001.pdf PDF
20170509_-_Appx_3.5_VCC_SWPPP_Stormwater_Pollution_Prevention_Plan.pdf PDF
20170705_-_Exhibit_D-CDRLs_D001-D004.pdf PDF
20170721_-_W911S2-17-B-0001.pdf PDF
20140812_-_Exhibit_C_-_Excavation_Permit_Policy.pdf PDF
20170509_-_Appx_3.3_VCC_Construction_Specifications.pdf PDF
20170511_-_Appx_3.4_VCC_Submittal_Register.pdf PDF
20150608_-_Endangered_Species_Act_Requirements.pdf PDF
20170608_-_Exhibit_F_-_Fort_Drum_Endangered_Species_Act_Implementing_Document.pdf PDF
20170705_-_Exhibit_D-CDRLs_D013-D016.pdf PDF
20170511_-_Appx_3.1_VCC_Drawings_Final_Design_For_Construction.pdf PDF
20170705_-_Exhibit_B_-_Sewer_Submittal_Procedures.pdf PDF
20170509_-_Appx_3.2_VCC_Narrative_Final_Design_For_Construction.pdf PDF
20170120_-_Exhibit_E_-_Confined_Space_Entry_Procedures.pdf PDF
20170515_-_Appx_3.7_Proposed_Comm_Tie-in_Location.pdf PDF
20130103_-_Appx_3.6_015_As-Built_Record_Drawings.pdf PDF
20170705_-_Exhibit_D-CDRLs_D009-D012.pdf PDF
20170515_-_Appx_3.7_Proposed_Comm_Tie-in_Location.dwg DWG drawing
20170705_-_Exhibit_D-CDRLs_D005-D008.pdf PDF
20120413_-_Appx_3.8__Access_Control_Points_Army_Standard.pdf PDF
20120530_-_Appx_3.6_002_PWES_Clearing_and_Grubbing.pdf PDF
20170705_-_Exhibit_A_-_Water_Supply_Improvement_Submittal_Procedures.pdf PDF
20120530_-_Appx_3.6_001_PWES_General_Requirements.pdf PDF
20170705_-_Exhibit_D-CDRLs_D017-D018.pdf PDF
Show all 28

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GLAZING TYPE LEGEND AND BLAST RESISTANT DATA:

NOTES:

1. ALL EXTERIOR DOORS THAT ARE GLAZED SHALL HAVE GLASS

TYPE "TLI"

2. ALL EXTERIOR DOORS, WINDOWS AND LOUVERS SHALL HAVE

BLAST RESISTANT FRAMING SECURELY ANCHORED TO THE

WALL.. LEVEL OF PROTECTION HIGH. NO AVAILABLE STANDOFF

DISTANCE.1.SEE SPECIFICATION FOR ADDITIONAL GLASS &

GLAZING REQUIREMENTS. BLAST RESISTANT AT EXTERIOR

GLAZING REFER TO SPECS.

3. INSULATION R-VALUE R-11. REFER TO SPECS.

4. PANIC BAR AT ALL EXIT DOORS

5. ANODIZED FINISH - COLOR GLIDDEN COMORANT 40YY10/101

A, B, C, D

L3

SEE WINDOW TYPES

6"DIAMETER

ALUM

FORMED

ANODIZED

PAINTED

TLI

MARK

SIZE (R.O.)

MAT

FRAME

FINISH TYPE

GLAZING

HEAD

JAMB

DETAILS

SILL

FIRE LABEL

& RATING

REMARKS

WINDOW & LOUVER SCHEDULE - VCC

A/A-501VCC B&C/A-501VCC

D/A-501VCC

"TLI"

FRAME TYPE DOOR TYPE

A B C

F G

T = TEMPERED GLASS (INTERIOR/CLEAR)

TLI = INSULATING GLASS AND BLAST RESISTANT GLAZING

6-MM (

" ) HS (2.54 MM SAFLEX HP PVB) 6 MM (

") HS

OWV = ONE WAY VISION GLASS

B

D

C

A

A-601VCC

A-501VCC

A-601VCC

A-501VCC

A-601VCC

A-501VCC

A-601VCC

A-501VCC

LOUVER TYPE

SCALE: 1/4" = 1'-0"

WINDOW TYPES

A-500VCC

F

A

A-502VCC

SIM

B

A-502VCC

SIM

A S

C H

E D

U L

E D

AS

SCHED

6" 6"

AS

SCHED

H

E D

U L

E D

AS

SCHED

2" 2"

SEE SCHEDULE

2" 2"

AS

SCHED

2" 2"

A

4'-9"

EXISTING WINDOWS - TO BE REPLACED

NEW WINDOW TYPE

F

I E

L D

V E

R I F

Y

2'-8"

(FIELD

VERIFY)

4'-9"

(FIELD

VERIFY)

8'-0"

(FIELD

VERIFY)

B C D

SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"

F

I E

L D

V E

R I F

Y

WINDOWS:

LOUVERS:

L4 6'-4"W x 1'-4"H

FORMED PAINTED

A/A-502VCC

B/A-502VCC C/A-502VCC

DOOR SCHEDULE - VCC

DR

NO.

DOOR LOCATION

DOOR SIZE

DOOR

FRAME DETAILS

FIRE LABEL

& RATING

HDWR

REMARKS

SILLJAMBMATTYPEMAT.TYPE

VESTIBULE

WAITING AREA

3'-0" X 7'-0"

PAIR 3'-0" X 7'-0"

PAIR 3'-2" X 7'-2" G

G

H

HM

AL

HM A

B

B P.S.

AL

P.S.

F

HM

C P.S.

SET

C/A-500VCC

J/A-500VCC

A/A-500VCC

K/A-500VCC

D/A-500VCC

G/A-500VCC

HEAD

H/A-500VCC

E/A-500VCC

L/A-500VCC

B/A-500VCC

PROCESSING

JANITOR

3'-0" X 7'-0"

104 MECH/ ELEC

PAIR 3'-0" X 7'-0" B

HM

A

P.S.

C/A-500VCC SIM

F/A-500VCC

E/A-500VCC SIM

F

HM C

P.S.

J/A-500VCC

G/A-500VCC

UNISEX TOILET

3'-0" X 7'-0" H/A-500VCC

BREAK ROOM

F

HM C P.S.

J/A-500VCC

G/A-500VCC

H/A-500VCC

3'-0" X 7'-0"

COMMUNICATIONS

3'-0" X 7'-0" F

HM P.S.

G/A-500VCC

H/A-500VCC

109 OFFICE

F

HM C P.S.

J/A-500VCC

G/A-500VCC H/A-500VCC

3'-0" X 7'-0"

C

TYPE TLI GLAZING

TYPE TLI GLAZING; SIDELIGHT

TYPE TLI GLAZINGC/A-500VCC SIM

"TLI"

H

H

E D

U L

E D

AS

SCHED

6" 6"

L4

H

E D

U L

E D

H

E D

U L

E D

H

E D

U L

E D

HARDWARE SCHEDULE - VCC

HEADING # 1.00:

THE HARDWARE FOR THIS DOOR HAS TO BE PROVIDED BY THE ALUMINUM DOOR MANUFACTURER.

HEADING # 02.00:

NUMBER KEYSET LOCATION FRAME DOOR SIZE LABEL HAND QTY TYPE

103 HM HM 3'-0" x 7'-0 x 1-3/4” B90 1 SNGL

QTY QTY DESCRIPTION FINISH MFGR

ACT/INACT

3 0 4-1/2 STD WT ( .134 ) HINGE TA2714 4-1/2” x 4-1/2” 26D MCKINNEY 101A

1 0 MORTISE LOCKSET L9080GD X 06A X 10-072 626 SCHLAGE 302A

1 0 WALL STOP, CONVEX 409 US32D ROCKWOOD 700A

HEADING # 03.00: DELETED - REFER TO HEADING NO. #07

HEADING # 04.00:

NUMBER KEYSET LOCATION FRAME DOOR SIZE LABEL HAND QTY TYPE

105 HM HM 3'-0" x 7'-0 x 1-3/4” B90 1 SNGL

QTY QTY DESCRIPTION FINISH MFGR

ACT/INACT

3 0 4-1/2 STD WT ( .134 ) HINGE TA2714 4-1/2” x 4-1/2” 26D MCKINNEY 101A

1 0 MORTISE PRIVACY L9040 X 06A X 10-072 X L283-722 626 SCHLAGE 303A

1 0 CLOSER 4040XP x REG x SRT AL LCN 501A

1 0 CONVEX 409 USD32D ROCKWOOD 700A

HEADING # 05.00:

NUMBER KEYSET LOCATION FRAME DOOR SIZE LABEL HAND QTY TYPE

107 HM HM 3'-0" x 7'-0 x 1-3/4” 1 SNGL

QTY QTY DESCRIPTION FINISH MFGR

ACT/INACT

3 0 4-1/2 STD WT ( .134 ) HINGE TA2714 4-1/2” x 4-1/2” 26D MCKINNEY 101A

1 0 MORTISE LOCKSET L9010 X 06A X 10-072 626 SCHLAGE 304A

1 0 CLOSER 4040XP x REG x SRT AL LCN 501A

1 0 WALL STOP, CONVEX 409 USD32D ROCKWOOD 700A

HEADING # 06.00:

NUMBER KEYSET LOCATION FRAME DOOR SIZE LABEL HAND QTY TYPE

108 HM HM 3'-0" x 7'-0" x 1-3/4” 1 SNGL

109 HM HM 3'-0" x 7'-0" x 1-3/4" --

QTY QTY DESCRIPTION FINISH MFGR

ACT/INACT

3 0 4-1/2 STD WT ( .134 ) HINGE TA2714 4-1/2” x 4-1/2” 26D MCKINNEY 101A

1 0 MORTISE LOCKSET L9050GD x 06A x 10-072 626 SCHLAGE 305A

1 0 WALL STOP, CONVEX 409 USD32D ROCKWOOD 700A

HEADING #07.00:

NUMBER 100, 102,& 104

THE HARDWARE FOR THESE THREE EXTERIOR DOORS HAS TO BE PROVIDED BY THE BLAST RESISTANT

MANUFACTURER,AS PART OF THE ENTIRE DOOR ASSEMBLY AND TESTED FOR BLAST RESISTANCE. FRAME IS TO BE THE

SEATED OPTION. EXTERIOR DOORS ARE INSULATED BLAST RESISTANT STEEL.

TYPE TLI GLAZING

TLI TLI TLI TLI

TLI

TLI

1'-0"

(FIELD

VERIFY)

TLI

SIDELIGHT

D O

O R

H

E I G

H T

L3

REFER TO MECH. DWGS. EXHAUST DUCT W/ BIRDSCREEN AND

HOODED WALL CAP

BLAST RESISTANT

BLAST RESISTANT

REFER TO

MECHANICAL

DRAWINGS

BLAST RESISTANT

BLAST RESISTANT

B E

S D

E S

I G

N

B

U I L

D

M V

A Z

Q U

E Z

A P

P R

0 1"

SHEET

REFERENCE

NUMBER

D E

S I G

N E

D

B

Y

D W

N

B

Y

C K

D

B

Y

S U

B M

I T

T E

D

B

Y

F I L

E

N

A M

E

S I Z

E

P L

O T

T E

D

B

Y

S C

A L

E

C O

N T

R A

T

N

U M

B E

R S

W O

K

D

M

B E

R

D A

T E

M A

R K

D E

S C

R I P

T I O

N D

A T

E A

P P

R

M A

R K

D E

S C

R I P

T I O

N D

A T

E

Ft. Drum

Public Works

Engineering Branch

54321

D

C

B

A

C O

N T

R A

C T

O R

DESIGN/BUILD

BES DESIGN/BUILD, LLC

766 Middle St, Fairhope, AL 36532

Phone: 251.990.5778

Fax: 251.990.3716

P r o j e c t

W o r k

O r d e r

N o

H

E J A

A

E

D e s i g n

W P

P

F o r

V i s i t o r

C o n t r o l

C e n t e r

A n d

L T

G

P a u l

G

C e r j a n

A

C P

F o r t

D r u m

N e w

Y r k

F I N

A L

D

E S

I G

N

F

N

S T

R U

C T

I O

N

N o

H

E

J A

N o

W

S

D

M

V

A Z

Q U

E Z

M

V

A Z

Q U

E Z

M

V

A Z

Q U

E Z

A N

S I

D

S C

H E

D U

L E

S

D O

O R

S

W

I N

D O

L

U V

E R

S

AE601

4' 8' 16'

SCALE 1/4 in. = 1 ft

BASE DESIGN

I N

F O

R M

A T

I O

N

U

P D

A T

E D

GLAZING TYPE LEGEND AND BLAST RESISTANT DATA:

NOTES:

1. ALL EXTERIOR DOORS THAT ARE GLAZED SHALL HAVE GLASS

TYPE "TLI"

2. ALL EXTERIOR DOORS, WINDOWS AND LOUVERS SHALL HAVE

BLAST RESISTANT FRAMING SECURELY ANCHORED TO THE

WALL.. LEVEL OF PROTECTION HIGH. NO AVAILABLE STANDOFF

DISTANCE.1.SEE SPECIFICATION FOR ADDITIONAL GLASS &

GLAZING REQUIREMENTS. BLAST RESISTANT AT EXTERIOR

GLAZING REFER TO SPECS.

3. INSULATION R-VALUE R-11. REFER TO SPECS.

4. PANIC BAR AT ALL EXIT DOORS

5. ANODIZED FINISH - COLOR GLIDDEN COMORANT 40YY10/101

A, B, C, D

L3

SEE WINDOW TYPES

6"DIAMETER

ALUM

FORMED

ANODIZED

PAINTED

TLI

MARK

SIZE (R.O.)

MAT

FRAME

FINISH TYPE

GLAZING

HEAD

JAMB

DETAILS

SILL

FIRE LABEL

& RATING

REMARKS

WINDOW & LOUVER SCHEDULE - VCC

A/A-501VCC B&C/A-501VCC

D/A-501VCC

"TLI"

FRAME TYPE DOOR TYPE

A B C

F G

T = TEMPERED GLASS (INTERIOR/CLEAR)

TLI = INSULATING GLASS AND BLAST RESISTANT GLAZING

6-MM (

" ) HS (2.54 MM SAFLEX HP PVB) 6 MM (

") HS

OWV = ONE WAY VISION GLASS

B

D

C

A

A-601VCC

A-501VCC

A-601VCC

A-501VCC

A-601VCC

A-501VCC

A-601VCC

A-501VCC

LOUVER TYPE

SCALE: 1/4" = 1'-0"

WINDOW TYPES

A-500VCC

F

A

A-502VCC

SIM

B

A-502VCC

SIM

H

E D

U L

E D

AS

SCHED

6" 6"

AS

SCHED

H

E D

U L

E D

AS

SCHED

2" 2"

SEE SCHEDULE

2" 2"

AS

SCHED

2" 2"

A

4'-9"

EXISTING WINDOWS - TO BE REPLACED

NEW WINDOW TYPE

F

I E

L D

V E

R I F

Y

2'-8"

(FIELD

VERIFY)

4'-9"

(FIELD

VERIFY)

8'-0"

(FIELD

VERIFY)

B C D

SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"

F

I E

L D

V E

R I F

Y

WINDOWS:

LOUVERS:

L4 6'-4"W x 1'-4"H

FORMED PAINTED

A/A-502VCC

B/A-502VCC C/A-502VCC

DOOR SCHEDULE - VCC

DR

NO.

DOOR LOCATION

DOOR SIZE

DOOR

FRAME DETAILS

FIRE LABEL

& RATING

HDWR

REMARKS

SILLJAMBMATTYPEMAT.TYPE

VESTIBULE

WAITING AREA

3'-0" X 7'-0"

PAIR 3'-0" X 7'-0"

PAIR 3'-2" X 7'-2" G

G

H

HM

AL

HM A

B

B P.S.

AL

P.S.

F

HM

C P.S.

SET

C/A-500VCC

J/A-500VCC

A/A-500VCC

K/A-500VCC

D/A-500VCC

G/A-500VCC

HEAD

H/A-500VCC

E/A-500VCC

L/A-500VCC

B/A-500VCC

PROCESSING

JANITOR

3'-0" X 7'-0"

104 MECH/ ELEC

PAIR 3'-0" X 7'-0" B

HM

A

P.S.

C/A-500VCC SIM

F/A-500VCC

E/A-500VCC SIM

F

HM C

P.S.

J/A-500VCC

G/A-500VCC

UNISEX TOILET

3'-0" X 7'-0" H/A-500VCC

BREAK ROOM

F

HM C P.S.

J/A-500VCC

G/A-500VCC

H/A-500VCC

3'-0" X 7'-0"

COMMUNICATIONS

3'-0" X 7'-0" F

HM P.S.

G/A-500VCC

H/A-500VCC

109 OFFICE

F

HM C P.S.

J/A-500VCC

G/A-500VCC H/A-500VCC

3'-0" X 7'-0"

C

TYPE TLI GLAZING

TYPE TLI GLAZING; SIDELIGHT

TYPE TLI GLAZINGC/A-500VCC SIM

"TLI"

H

H

E D

U L

E D

AS

SCHED

6" 6"

L4

H

E D

U L

E D

H

E D

U L

E D

H

E D

U L

E D

HARDWARE SCHEDULE - VCC

HEADING # 1.00:

THE HARDWARE FOR THIS DOOR HAS TO BE PROVIDED BY THE ALUMINUM DOOR MANUFACTURER.

HEADING # 02.00:

NUMBER KEYSET LOCATION FRAME DOOR SIZE LABEL HAND QTY TYPE

103 HM HM 3'-0" x 7'-0 x 1-3/4” B90 1 SNGL

QTY QTY DESCRIPTION FINISH MFGR

ACT/INACT

3 0 4-1/2 STD WT ( .134 ) HINGE TA2714 4-1/2” x 4-1/2” 26D MCKINNEY 101A

1 0 MORTISE LOCKSET L9080GD X 06A X 10-072 626 SCHLAGE 302A

1 0 WALL STOP, CONVEX 409 US32D ROCKWOOD 700A

HEADING # 03.00: DELETED - REFER TO HEADING NO. #07

HEADING # 04.00:

NUMBER KEYSET LOCATION FRAME DOOR SIZE LABEL HAND QTY TYPE

105 HM HM 3'-0" x 7'-0 x 1-3/4” B90 1 SNGL

QTY QTY DESCRIPTION FINISH MFGR

ACT/INACT

3 0 4-1/2 STD WT ( .134 ) HINGE TA2714 4-1/2” x 4-1/2” 26D MCKINNEY 101A

1 0 MORTISE PRIVACY L9040 X 06A X 10-072 X L283-722 626 SCHLAGE 303A

1 0 CLOSER 4040XP x REG x SRT AL LCN 501A

1 0 CONVEX 409 USD32D ROCKWOOD 700A

HEADING # 05.00:

NUMBER KEYSET LOCATION FRAME DOOR SIZE LABEL HAND QTY TYPE

107 HM HM 3'-0" x 7'-0 x 1-3/4” 1 SNGL

QTY QTY DESCRIPTION FINISH MFGR

ACT/INACT

3 0 4-1/2 STD WT ( .134 ) HINGE TA2714 4-1/2” x 4-1/2” 26D MCKINNEY 101A

1 0 MORTISE LOCKSET L9010 X 06A X 10-072 626 SCHLAGE 304A

1 0 CLOSER 4040XP x REG x SRT AL LCN 501A

1 0 WALL STOP, CONVEX 409 USD32D ROCKWOOD 700A

HEADING # 06.00:

NUMBER KEYSET LOCATION FRAME DOOR SIZE LABEL HAND QTY TYPE

108 HM HM 3'-0" x 7'-0" x 1-3/4” 1 SNGL

109 HM HM 3'-0" x 7'-0" x 1-3/4" --

QTY QTY DESCRIPTION FINISH MFGR

ACT/INACT

3 0 4-1/2 STD WT ( .134 ) HINGE TA2714 4-1/2” x 4-1/2” 26D MCKINNEY 101A

1 0 MORTISE LOCKSET L9050GD x 06A x 10-072 626 SCHLAGE 305A

1 0 WALL STOP, CONVEX 409 USD32D ROCKWOOD 700A

HEADING #07.00:

NUMBER 100, 102,& 104

THE HARDWARE FOR THESE THREE EXTERIOR DOORS HAS TO BE PROVIDED BY THE BLAST RESISTANT

MANUFACTURER,AS PART OF THE ENTIRE DOOR ASSEMBLY AND TESTED FOR BLAST RESISTANCE. FRAME IS TO BE THE

SEATED OPTION. EXTERIOR DOORS ARE INSULATED BLAST RESISTANT STEEL.

TYPE TLI GLAZING

TLI TLI TLI TLI

TLI

TLI

1'-0"

(FIELD

VERIFY)

TLI

SIDELIGHT

D O

H

I G

H T

L3

REFER TO MECH. DWGS. EXHAUST DUCT W/ BIRDSCREEN AND

HOODED WALL CAP

BLAST RESISTANT

BLAST RESISTANT

REFER TO

MECHANICAL

DRAWINGS

BLAST RESISTANT

BLAST RESISTANT

B E

S D

E S

I G

N

B

U I L

D

M V

A Z

Q U

E Z

A P

P R

0 1"

SHEET

REFERENCE

NUMBER

D E

S I G

N E

D

B

Y

D W

N

B

Y

C K

D

B

Y

S U

B M

I T

T E

D

B

Y

F I L

E

N

A M

E

S I Z

E

P L

O T

T E

D

B

Y

S C

A L

E

C O

N T

R A

T

M

B E

R S

W O

K

D

M

B E

R

D A

T E

M A

R K

D E

S C

R I P

T I O

N D

A T

E A

P P

R

M A

R K

D E

S C

R I P

T I O

N D

A T

E

Ft. Drum

Public Works

Engineering Branch

54321

D

C

B

A

C O

N T

R A

C T

O R

DESIGN/BUILD

BES DESIGN/BUILD, LLC

766 Middle St, Fairhope, AL 36532

Phone: 251.990.5778

Fax: 251.990.3716

P r o j e c t

W o r k

O r d e r

N o

H

E J A

A

E

D e s i g n

P

F r

V i s i t o r

C o n t r o l

C e n t e r

A n d

L T

G

P a u l

G

C e r j a n

A

C P

F o r t

D r u m

N e w

Y r k

F I N

A L

D

E S

I G

N

F

N

S T

R U

C T

I O

N

N o

H

E

J A

N o

W

S

D

M

V

A Z

Q U

E Z

M

V

A Z

Q U

E Z

M

V

A Z

Q U

E Z

A N

S I

D

S C

H E

D U

L E

S

D O

O R

S

W

I N

D O

L

U V

E R

S

AE601

4' 8' 16'

SCALE 1/4 in. = 1 ft

BASE DESIGN

I N

F O

R M

A T

I O

N

U

P D

A T

E D

16008R2 - OD1 - AE800 POV CANOPY, PLANS, ELEV, SECT
16008R - OD1 - AE802- POV CANOPY
16008R - OD1 - AE803- POV CANOPY
16008R - VCC - AE101- FLOOR PLAN
16008R - VCC - AE102 - REFLECTED CEILNG PLAN
16008R - VCC - AE200- BUILDING EXTERIOR ELEVATIONS
16008R - VCC - AE401 WALL PARTITIONS

File details come from the government source that posted it. Updated .