Salient Characteristics - Amendment P0001.doc

DOC document 81 KB Posted

Attached to
Combined Synopsis/Solicitation for Commercial Items - One (1) Vector Network Analyzer (VNA) - Amendment P0001
Solicitation number
W911QX23Q0155
Issued by

About this file

This document outlines the salient technical requirements for a Vector Network Analyzer (VNA) solicitation by the Department of the Army Materiel Command Army Contracting Command Aberdeen Proving Ground. The solicitation requires a four-port VNA with a maximum operating frequency of at least 40 gigahertz, minimum operation frequency of at least ten megahertz, and dynamic range of at least 95 decibels across the entire specified frequency range. Additional requirements include trace noise thresholds, temperature instability limits, output power ranges, power accuracy and linearity specifications, third harmonic and noise floor levels, and on-site support and training provisions. The VNA must integrate with existing Government-owned equipment and include intuitive software with future analysis options. A minimum two-year warranty is also required.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics

Commercial Availability Certification:

I have evaluated the commercial marketplace and determined that all of the salient characteristics documented below are available in products/services offered in the commercial marketplace.

Signature (typed name): Owen Vail Technical Point of Contact (TPOC) or Contracting Officer’s Representative (COR)

Technical Requirements for Vector Network Analyzer (VNA) The Advanced Electronics Branch at the Army Research Laboratory (ARL) in service of the Gordian TOPS program requires one (1) Vector Network Analyzer (VNA) with the following minimum characteristics:

· Four (4) ports

· Maximum operating frequency of at least 40 gigahertz (GHz)

· Minimum operation frequency of at most ten (10) megahertz (MHz)

· Dynamic Range of at least 95 decibels (dB) over the entire frequency range stated above

· Trace noise at zero (0) decibels-milliwatt (dBm) source power and zero (0) dB reflection of less than a hundredth (0.01) dB root mean square (RMS) at 10 kHz Intermediate Frequency Band Width (IFBW) for 40 GHz

· Trace noise at zero (0) dBm source power and zero (0) dB reflection of less than four thousandths (0.004) dB RMS at ten (10) kHz IFBW for ten (10) MHz

· Temperature instability of less than twenty-five thousandths (0.025) decibels per Kelvin (dB/K) at negative (-) ten (10) dBm source power over the entire frequency range stated

· Maximum output power of at least positive (+) two (2) dBm at 40 GHz, with typical operation of at least positive (+) ten (10) dBm over the frequency range between ten (10) MHz and ten (10) GHz

· Minimum output power of at most negative (-) 30 dBm

· Power level inaccuracy of at most two and a half (2.5) dB over the entire frequency range stated

· Power linearity of less than two (2) dB referenced to negative (-) ten (10) dBm over the entire frequency range stated

· Third harmonics at zero (0) dBm of at most negative (-) 17 dBc over the entire frequency range stated

· Typical noise floor of at most negative (-) 115 dBm over the entire frequency range stated

· On-site support for upgrades and software updates, as well as email and phone access to applications experts on an as-needed basis for at least two (2) years

· Instrument fundamentals and operations starter shall be included

· Shall integrate with 2.4 millimeter (mm) SubMiniature version A (SMA) connections of an existing Government-owned Lakeshore vertical field probe station (CRX-VF) located at Adelphi Laboratory Center

· Intuitive user interface core software shall be provided with future options for time domain analysis and harmonic analysis

· Shall include at least two (2) years of warranty

· Shall include at least one (1) day of in-person training for standard users and functionalities of the software, as well as initial setup and standards testing with ground-signal-ground (GSG) probes.

Contracting Officer:

Template last updated 07/28/2016