SOL_Amendment_W911N2-18-R-0025_0001.pdf
PDF 387 KB Posted
- Attached to
- Firefighting Personal Protective Equipment
- Solicitation number
- W911N2-18-R-0025
About this file
Solicitation Amendment
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SOL_W911N2-18-R-0025.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RYAN T. POE
LETTERKENNY CONTRACTING OFFICE
1 OVERCASH AVENUE CCAM-ALK
717-267-9481
CHAMBERSBURG PA 17201-4150
W25G1Q8130R008
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of this amendment is to change the "equal to" Part number in CLINS 0003, 1003, 2003, 3003, and 4003 and also revised the salient characteristics. See Summary of Changes. All other terms and conditions remain the same.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 5
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 19-Jul-2018
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W911N218R0025
X 9B. DATED (SEE ITEM 11)
17-Jun-2018
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
19-Jul-2018
CODE
LETTERKENNY ARMY DEPOT
LETTERKENNY CONTRACTING OFFICE - ACC
1 OVERCASH AVENUE, ATTN: CCAM-ALK, BLDG 2S
CHAMBERSBURG PA 17201-4150
W911N2 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE W911N2
FACILITY CODECODE
EMAIL:TEL:
W911N218R0025
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 1449 - CONTINUATION SHEET
SUPPLIES OR SERVICES AND PRICES
CLIN 0003
The CLIN extended description has changed from:
Structural Firefighting Protective Hood: Majestic PAC II (P84 BLK PAC II), Lenzing P-84 Natural, or equivalent shoulder length bibbed hood. (See Salient Characteristics)
To:
Structural Firefighting Protective Hood: Majestic PAC II (P84 PAC II), Lenzing P-84 Natural, or equivalent
CLIN 1003
Structural Firefighting Protective Hood: Majestic PAC II (P84 BLK PAC II), Lenzing P-84 Natural, or equivalent
Structural Firefighting Protective Hood: Majestic PAC II (P84 PAC II), Lenzing P-84 Natural, or equivalent
CLIN 2003
Structural Firefighting Protective Hood: Majestic PAC II (P84 BLK PAC II), Lenzing P-84 Natural, or equivalent
Structural Firefighting Protective Hood: Majestic PAC II (P84 PAC II), Lenzing P-84 Natural, or equivalent
CLIN 3003
Structural Firefighting Protective Hood: Majestic PAC II (P84 BLK PAC II), Lenzing P-84 Natural, or equivalent
Structural Firefighting Protective Hood: Majestic PAC II (P84 PAC II), Lenzing P-84 Natural, or equivalent
CLIN 4003
Structural Firefighting Protective Hood: Majestic PAC II (P84 BLK PAC II), Lenzing P-84 Natural, or equivalent
Structural Firefighting Protective Hood: Majestic PAC II (P84 PAC II), Lenzing P-84 Natural, or equivalent
The following have been modified:
PURCHASE DESCRIPTION
SPECIFICATIONS
SPECIFICATIONS
Letterkenny Army Depot (LEAD) A3H30020870001—Turn Out Gear
1.0 REQUIREMENT: The contractor shall provide the structural firefighting protective gear, wildland firefighting protective gear and other equipment specified below to the requirements of NFPA 1971, NFPA 1977 or to OSHA/NIOSH and generally accepted industry standards where no NFPA standard exists. Vendor to provide onsite measuring of garments for coat and pant ensemble. Vendor shall deliver custom items (Coat and Pants) within 75 days of order and all other items with 30 days of order. The purpose of the clothing is to provide protection during structural firefighting operations where there is a threat of fire or when certain physical hazards are likely to be encountered, such as during non-fire-related rescue operations, emergency medical operations, and victim extrication. All components and composites used in the construction of structural firefighting garments shall be third party tested, certified and listed for compliance to NFPA 1971. The label of the third party tester shall denote certification. The manufacturer shall be registered to the ISO Standard 9001 to assure a satisfactory level of quality.
The manufacturer shall not sub-contract the sewing of any garment component unless the sub-contractor is also certified to the requirements of ISO 9001 and has been listed as a sub-contractor. The garment composite, consisting of the outer shell, moisture barrier and thermal liner, shall provide a Thermal Protective Performance (TPP) of not less than 35 when tested, and a Total Heat Loss (THL) of not less than 205 when tested in accordance with NFPA 1971 standard. There shall be a bar code label permanently affixed to each garment for tracking purposes. The bar code shall contain a minimum of the following information:
Unique serial number
Item description (brand, model, material color) Lot information (date of mfg., size, etc.)
Material description The standard to which the garment is compliant The bar code shall be able to withstand customary wash and wear cycles.
Each garment shall include a User Information Guide with information required by NFPA 1971.
Each garment shall have a limited lifetime warranty against defects in material and workmanship which should be registered using the internet address on the provided sticker with each garment.
DESCRIPTION:
1.1 Coat Requirements: LION Super Deluxe (Janesville # CSTM-35), “Traditional Style” Turn out Coat, or equivalent Thirty Five (35) inch length.
-6.5 ounce Armor AP Gold outer shell -K4 Glide Ice Liner system, completely detachable from shell. Glide ice face cloth quilted to 2.3 oz. Nomex/Kevlar spunlace and 1.5 oz. Araflo and a Stedair 4000 Nomex/pajama check laminated membrane. Equivalent system meeting THL/TPP values acceptable.
-Wristlets to extend over hand with thumb tab or hole and be of a Kevlar/Nomex/Spandex material.
-Coat to have an inner yoke reinforcement. Specify type provided on bid.
-Coat storm flap closure system with inner zipper and hook and loop closure.
-Elbows, cuffs and shoulders to be reinforced with self-material.
- 9X9X2 semi bellows reinforced hand warmer pockets to be provided on each side of coat.
-Radio pocket of reinforced self-material with Velcro closure to be provided on left chest.
Dimensions approximately 3.5X7.5X2. With a self-material mic tab mounted above the pocket.
-Self fabric with Velcro closure and tab for holding a Survivor Streamlight on the right chest. Provide a second self-material tab or reinforced riveted reverse snap hook above the holder for the light.
-Provide 3 inch Lime/Yellow Scotchlite reflective Triple Trim in a New York City pattern.
-Provide a lettering patch at rear hem of coat. Patch to be attached securely by snaps, Velcro or combination. Patch to be approximately 5 X 18. Letters to be 3” Lime Yellow sewn on. Name to be provided on order.
-Sewn on 4” Lime Yellow Scotchlite number “13” located on the upper back.
-Coats provided in even chest sizes with corresponding sleeve lengths (short to extra-long).
1.2 Pants with Suspender Requirement: LION Super Deluxe pant (Janesville PSDM) with low rise waist, or equivalent “traditional” pant.
-6.5 ounce Armor AP gold outer shell.
- K4 Glide Ice Liner system, completely detachable from shell. Glide ice face cloth quilted to 2.3 oz. Nomex/Kevlar spun lace and 1.5 oz. Araflo and a Stedair 4000 Nomex/pajama check laminated membrane. Equivalent system meeting THL/TPP values acceptable.
-3” lime/yellow Scotchlite triple trim applied around circumference of legs 2”-3” from the bottom of the cuff.
-Pants shall be available in even waist sizes with leg inseam lengths ranging from short to long.
-Suspenders or suspender system to be provided with pants.
-The pants closure system will be of the storm fly design, closed by a zipper and retained closed by a Velcro closure and snap or/hook and D ring system.
-Knees will be reinforced and designed to enhance knee flex, as well as provide padding for crawling.
-An integrated Class II rescue harness system meeting NFPA 1983, latest edition will be incorporated into the pants design or closure system.
-Pant cuffs will be reinforced and design will incorporate features to prevent the rear of the cuff from riding under the boots.
-Full bellows style pockets will be provided on both pant legs, be approximately 10X10by 2 and closed by a flap secured with hook and loop tape.
1.3 Structural Firefighting Protective Hood: Majestic PAC II (P84 PAC II), Lenzing P-84 Natural, or equivalent shoulder length bibbed hood.
1.4 Structural firefighting boot: Globe 1201400 14” leather structural boots, or equivalent. Sizes 5-14 men or women, available in narrow, wide and Extra Wide, OR equivalent boot and size range.
1.5 Traditional style firefighter helmet and identification front piece: Cairns 1044XDY Deluxe configuration helmet, yellow with Defender visor, or equivalent. Identification front to be “New York City” style six and one quarter inch (6.25) high with a top and bottom lettering panel and pinned insert type as described:
- Black body color, with White stitching color, Red panel color, Reflective White panel lettering color, Top Panel will be specified to read “ENGINE” or “INSPECTOR”, Bottom panel to read “LETTERKENNY”, Insert body color to be Black, Color of insert characters to be White Sunken Reflective and read “13”
1.6 Cairns 1044XDY Deluxe helmet, white with Defender visor, or equivalent. Identification front to be of insert style New York City type as described:
- White body color, with White stitching color, Red panel color, Reflective White panel lettering color, Top Panel will be specified to read “CAPTAIN”, “ASST CHIEF”, or “FIRE CHIEF”, Bottom panel to read “LETTERKENNY”, Insert body color to be White, Color of insert characters to be Red Sunken Reflective and read “13”
1.7 Structural Firefighting Glove: Pro-Tech 8 Fusion (PT-8 SC) NFPA structural firefighting glove or equivalent.
Glove to be available in size ranges small- 2XL in a short cuff design to accommodate extended coat wristlets.
1.8 Personal Firefighter Light: Right angle design, LED light source, rechargeable with no included charger, with spring loaded clip and D-ring system to secure to coat, color orange. Survivor Streamlight (W-90500) or equivalent.
1.9 Extrication/rescue gloves, short cuff, reinforced palm and fingers, padded back and knuckles, Lion Mechflex or equivalent style glove in small through 2-XL.
1.10 Eight (8) inch NFPA 1977 Wildland/station boot. Military grade AB leather with Vibram lug sole, puncture resistant bottom plate, full wrap around Goodyear welt and molded heel counter, zipper closure system, and Cambrelle lining. Pro Warrington model 3003, or equivalent.
(End of Summary of Changes)
File details come from the government source that posted it.