TECH_EXHIBIT_B_-_Drawings.pdf
PDF 32 MB Posted
- Attached to
- Replace HVAC System in Building 1937 Federal contract opportunity
- Solicitation number
- W91151-17-B-0006
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Abstract_of_Bids-17-B-0006_(IFB).pdf | ||
| C-103_Revised_Drawings.pdf | ||
| Asbestos_Survey.doc | DOC document | |
| Approved_Amendment_2.pdf | ||
| Approved_Amendment_1.pdf | ||
| Site_Visit_Sign_in_Sheet.pdf | ||
| TECH_EXHIBIT_A_-_Specifications.pdf | ||
| Approved_Solicitation.pdf | ||
| Attachment_1-_Specifications_Appendix_A_04-Aug-2016.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
·v;
" 0 ,,,1 c:
~3 u::
G I ,._ "' "' <ii cl.
" e 0..
6 z ti'.
w w z (3 z w G
~I z 4
N
A
OKLAHOMA
SANTA FE
MEXICO
VICINITY MAP
100 200
SCALE IN MILES
B
GULF OF
MEXICO
HWY190
FORT HOOD AREA MAP
SCALE IN MILES
TURKEYRUN
FORT HOOD MILITARY RESERVATION
MAIN CANTONMENT AREA
SCALE IN MILES
REPLACE HVAC SYSTEM
FORT HOOD,TEXAS
PROJECT NO: CA093390P
E
BUILDING LEGEND (POINTS OF INTEREST\
CD Ill CORPS HEADQUARTERS
@ DARNALL ARMY HOSPITAL
@ BUILDING 4612 (DIRECTORATE OF PUBLIC WORKS)
@) PROJECT SITE
BLDG 1937
FORT HOOD DIRECTORATE OF PUBLIC WORKS-ENGINEERING DIVISION
SHEET
G-101 C-101 D-101A D-101 B D-102 M-101A M-101 B M-102 M-501 M-502 M-503 M-601 M-602 M-701 M-702 M-703
F
INDEX OF DRAWINGS
SHEET DESCRIPTION
COVER SHEET
SITE PLAN - UTILITIES
DEMOLITION PLAN - MECHANICAL - AREA A
DEMOLITION PLAN - MECHANICAL - AREA B
DEMOLITION PLAN - ENLARGED MECHANICAL
MECHANICAL PLAN - AREA A
MECHANICAL PLAN - AREA B
ENLARGED MECHANICAL PLAN
CHILLED WATER PIPING DIAGRAM
HOT WATER PIPING DIAGRAM
MECHANICAL DETAILS
MECHANICAL SCHEDULE-1
MECHANICAL SCHEDULE-2
BOILER I CHILLER CONTROLS
AHU CONTROLS
MECHANICAL CONTROLS
GENERAL SYMBOLS
DETAIL NUMBER
-----~ REFERENCE TO
NORTH SYMBOL & REVISION NUMBER
NOTE BY SYMBOL ---0 WALL TYPE MARK
WINDOW MARK [QQQJ DOOR MARK s...., ..... ________________________________________________________________________________________________________________________ .,.. ________________________________________________________________________________ ...., ________________________________________ ...
w I C/)
Cf)
I w
::s a_ w 0:::
1-w w I
0:::
w u
Bldg. No.
CA093390P
Project No.
SHEET
REFERENCE
NUMBER
G-101
"' 0
·v;
" 0
,,,' c:
~3 u::
G I ,._ "' "' <ii cl.
" e 0..
6 z ti'.
w w z (3 z w G
~I z 4
A B
---- UGE-----UGE ' I
I I
19035
----9 __
''c.,s -
I
I I r-
19041 /
I I
_ 1
' -"'c,, I I
I I
I
I
,f ss '
'°'>s -
I I
I I
I r-ss -
'°'>s'
I I I I I
I
-"'c,,, I
-"1o I
',f
'Ss
'::._ Ss ..._
- - - ':::· .::::.:-: "::: '. ': Ss \
............ --"'l.. --..., \
'°'>s' -- '°'>s' --
I c
20 40 80
SCALE (FEET)
I I
,f
I I
I
I
D
I I
I I
I
I
J?
I I
I
I
I I
I
I
SS -------~
I I
I I
I
J?
I I
I
J?
I
I I
I I
I
E
----- OHC -----
----- OHE -----·
-----UOE-----UGE- - - - ·
·-----GAS-----
----- SS -----·
SD -----
T -----
------w------w------w----
--41----+---+--
F
LEGEND:
EXISTING OVERHEAD COMMUNICATIONS LINE
EXISTING OVERHEAD ELECTRIC LINE
EXISTING UNDERGROUND ELECTRIC LINE
EXISTING GAS LINE
EXISTING SANITARY SEWER LINE
EXISTING STORM DRAIN LINE
EXISTING TELECOMMUNICATION DUCTBANK
EXISTING WATER LINE
EXISTING FENCE LINE
EXISTING TRAFFIC SIGNAL
EXISTING LIGHT POLE
EXISTING POWER POLE
EXISTING TRANSFORMER - POLE MOUNTED
EXISTING RISER
EXISTING ELECTRIC METER
EXISTING COMMUNICATIONS PEDESTAL
EXISTING GAS REGULATOR
EXISTING GAS VALVE
EXISTING WATER METER
EXISTING WATER VALVE
EXISTING FIRE HYDRANT
EXISTING SANITARY SEWER EQUIPMENT
EXISTING WASTEWATER CLEANOUT
EXISTING WASTEWATER MANHOLE
EXISTING WASTEWATER VALVE
EXISTING TELECOMMUNICATION MANHOLE
s tt::============:::c============::::I:========~~---r~~~~~~---.~~~~~~---,r--~~~~~__J
"' f- >-ii5c:>_J I~B XO en wow ;;;1mgs ()D:'.o._ zOc:t:
Iu_::J () 0..
w f-en ~en~ w:.'.w f-D:'.f- <(O • c:t:S;O
8'28 ()-'I wO'.lf-
Q;i5:~ 0 u.
w I-
(f)
I w ....J a_ w 0::::
"' 0
-t z it'. 27 "'"' w o~ z f- I "O I () <(
~~ Wc:t:
....,O'.l .Q> Ill 0 <( "' <( D:'. . " . 0.. <( 0 <( o<S en ci x 0 w
N f- ~a::w6 ~tl1u.o 0~f"'.O.,.
oc:>zI"'!t ....1Z<(j.-'.~ c:JW(l)LL......_ w I- ....J
I-z ....J a..
w I-
Bldg. No.
CA093390P
Project No.
SHEET
REFERENCE
NUMBER
C-101
"O
6 c ·v;
" 0
,,,' c:
~3 u::
G I ,._ "' "' <ii cl.
" e 0..
6 z ti'.
w w z (3 z w G
~I z 4 lJd
A
•11•11•11•11• I
B
D D 101A 102 c D
: EXISTING )
CONDENSING ~
UNIT ~
~------- l I
•-GAS - - - - GAS - - - - - - - - GAS -
~----1
WALK
IN
COOLER
KITCHEN
02D
I I
EXISTING I
COMPRESSOR 1
1 I
PAD I
I I
L----
EF
FD ILEJ - SNACK BAR FD
~~ ~-~ ~ 1@1 -~ t>\J-- - - - - - t>-z.r~ ---r-z.J---
DINING
OQD
Ml•••••••••••• ll'ff'• • • • • • • • • .n• • • • • • • • • • • • ~ MATCHLINE - SEE D-1018
FD~
MECH ROOM
I I I I
I I
GD
I .- ~-;r - - - - - - - - ~-~ tit¥ _____ -: _ J>\J S~E ~1 ~
• --~r--
1 I II
I I._ __
I I
SALES
OQD
I I I
I I .(---l
~ I I I I ,.
I I I I I I I I
STORAGE
<f> ~;L~~4~~;.10N PLAN - MECHANICAL - AREA A 0--~4 ~~aiiiiiiiiiiiiiiiiiiil12 \fl7 SCALE (FEET)
Ill
E F
NOTES:
1. DEMO ALL EXISTING SUPPLY AIR DIFFUSERS, RETURN AIR GRILLES
AND EXHAUST GRILLES .
2. DEMO EXISTING EXHAUST FANS (EF-4 AND EF-5) AND ASSOCIATED
EXHAUST DUCTS AND GRILLES.
3. DEMO GYPSUM BOARD CEILING IN MEN AND WOMEN RESTROOMS.
(FOR ACCESS TO REMOVE AND REPLACE THE EXHAUST FANS AND
ASSOCIATED ACCESSORIES)
KEY NOTES:
G EXHAUST FAN TO BE DEMO'D
0 EXISTING THERMOSTAT TO BE DEMO'D
0 DEMO THE WALL INSIDE THE MECH ROOM (APPROX 11 ' W IDE X 12' HIGH)
CWR
cws
HWR
HWS
NO.
EF-1
EF-2
EF-3
EF-4
EF-5
SF-1
EQUIPMENT LIST
DESCRIPTION
EXHAUST FAN
EXHAUST FAN
EXHAUST FAN
EXHAUST FAN
EXHAUST FAN
SUPPLY FAN
LEGEND:
EXISTING CONDENSER WATER RETURN LINE
EXISTING CONDENSER WATER SUPPLY LINE
EXISTING HEATING WATER RETURN LINE
·---CD---- --CD---
___ GAS ---
EXISTING HEATING WATER SUPPLY LINE
EXISTING CONDENSATE DRAIN LINE
EXISTING GAS LINE
EXISTING ABANDON GAS LINE
EXISTING 2' X 2' SUPPLY AIR DIFFUSER
EXISTING 2' X 2' RETURN AIR DIFFUSER
AIR FLOW DIRECTION
EXISTING THERMOSTAT
EXISTING ELECTRICAL PANEL WITH 3' CLEARANCE
SPACE - FRONT OF PANEL
EXISTING EXHAUST FAN
EXISTING 18" VENT- OUTSIDE AIR INTAKE
EXISTING FLOOR DRAIN
~KEYPLAN
w I C/)
Cf)
I w
::s a..
w 0::::
Bldg. No.
CA093390P
Project No.
SHEET
REFERENCE
NUMBER
D 101A
"O
Ill
9 c "' " 0
I
"' c
~3 u::
G I ,._ O")
"' <ii 0..
"' O") O")
"' 0 y u·
0..
I
6 z ti'.
w w z (3 z w G
I z lJd
N
" N s
A I B I c I D I
· · ·- .. - .. -.............. ,.. .. - .. - .. - .. -· i-:::__·_ :__~ ~"_ - - _~/~A- -I -------,.-
: - - - - - - - - - - =--74-~ I
• • • • • 1 •••••• ..... H •••••• Ji1-..c.~11.1-mw•~i~•~·1• ~!11 · • • · · • · · • · · • · · • · ··-"' • • • • • •t. ; 1----~" ~ n •11•11•11•11•11•11•1fi:"'
DINING
UP- -up tt __ j
I I I I I ~
I ~ "-;pi~ dFE~~J
I
UP
I I I I I t>~ I I I I I I I I
G(ME:Ot 1 8
1 1 1 I I ~-;;p
\ >I ~
<f> ~;L~~4~~;.10N PLAN - MECHANICAL - AREA B 0--~4 ~~aiiiiiiiiiiiiiiiiiiil12 \fl7 SCALE (FEET)
I I I I
E
-t:J
I F
NOTES:
1. DEMO ALL EXISTING SUPPLY AIR DIFFUSERS, RETURN AIR GRILLES
AND EXHAUST GRILLES.
2. DEMO EXISTING THERMOSTAT TO INCLUDE WIRING AND CONDUIT.
KEY NOTES:
0 DEMO THERMOSTAT
- CWR -
- cws -
- - HWR -
- - HWS - -
----CD------CD----
___ GAS ---
ll ____ J
~:=<1 ~-J
D
FD~
LEGEND:
EXISTING CONDENSER WATER RETURN LINE
EXISTING CONDENSER WATER SUPPLY LINE
EXISTING HEATING WATER RETURN LINE
EXISTING HEATING WATER SUPPLY LINE
EXISTING CONDENSATE DRAIN LINE
EXISTING GAS LINE
EXISTING ABANDON GAS LINE
EXISTING 2' X 2' SUPPLY AIR DIFFUSER
EXISTING 2' X 2' RETURN AIR DIFFUSER
AIR FLOW DIRECTION
EXISTING THERMOSTAT
EXISTING ELECTRICAL PANEL WITH 3' CLEARANCE
SPACE - FRONT OF PANEL
EXISTING EXHAUST FAN
EXISTING 18" VENT- OUTSIDE AIR INTAKE
EXISTING FLOOR DRAIN
,,.-··--· .. - ·-··-··-··-"!II J
I )
~KEYPLAN
I w I- Cf)
Cf)
I w ...J a..
w 0:::
it'.
w
~ z f--I
WQ:'.
., Ill 0 <( D:'. .
0.. <(
"' 0 z
"'"' o~ - "O I
.Q> Ill "' <( " . 0 <(
IIl z<C <(W ...J 0:::
a.. <( z I
0 ...J 1-() ...J -oz
WI
o~
Bldg. No.
CA093390P
Project No.
SHEET
REFERENCE
NUMBER
D
A c::
c 'O N
9 c::
"' " 0
I
"' c::
~3 u::
G I ,._ "' "' <ii 0..
"' "' "' "' 0 y u·
0..
I
6 z ti'.
w w z (3 z w G
I z lJd
"' "' N s
I B I c I
_______ T _______ _ , I ! I ! I ! I
8 ! I r---- GAS --- - -- S --- f-~:-~~AS~-1 : I r-1;~1 -· __,I -,-~~~ I ,- nw~ J- S - ( 2 \-1 : I IT] ~~~1 /---w---~ -!I
,- \I7 I I i- \ 1 I J
~ 6 l.J ; - - - - -1= =:::: .L - '1- 1 Ul ~ - --: 0 / MECH ROOM I 11 -
~ "' 1 Y c'i ~ I , ~ I~~ ,,,..,.D I 1 1 '-v-co..m -.-co-----ce~::... __ -!-! / ~ - - -i : L '--~H i---"-£Er~-~-----:$ ! I //
-i 1\'r11 --i ~iv ~~~r;:; ----- -~ I: : ~ )\ l:1'- l"=--~-
:t I 1\...1../AHUI I HC I _u ---, 1 I, 4 I
HC I' ,
: 1 : 16 11 11 I~) l ~1 Fl'(jf'.IS--i :y 11 i I\.:'.
1 _~J - - - - - I I ' I
I Ula: I 16 a:Ul 11
IH !-,-.---",------\Y H'
I I I IL '-~D------CD---\ J I
STORAGE
O}D
1 11 ~ ~ ---=-~-=--~r-=---=---=-'-fr _'.j r--
~ ~ I I \... _ I ' ' / STORAGE
~ v ~ ~~~~(J-=t_M.-,= ~~~ ~' / GD
I "{ L HC .L HC ' ' I ---- - 2 - 1 3 1--1-------1----
: 10:--1--:-iji--r---1-©i-1 I L I I I I I I - I I I I I I I
., --+-- I s I c:o I ±:::+=± ±::-===+===± I
D I E I F
NOTES:
1. DEMO EXISTING AIR COOLED CONDENSING UNIT (ACC-1) AND ALL ASSOCIATED REFRIGERANT PIPING.
2. DEMO AIR HANDLING UNIT (AHU-1), ALL ASSOCIATED DUCTWORK IN MECH. ROOM, CONTROL AND REFRIGERANT PIPING.
3. DEMO HOT WATER HEATING COILS (HC-1 , 2, 3 &4) IN THE DUCTS AND ALL ASSOCIATED ACCESSORIES.
4. DEMO ALL HOT WATER SUPPLY AND RETURN PIPING FROM COILS TO BOILER. EXISTING BOILER (B-1) AND ASSOCIATED
CIRCULATING PUMP TO REMAIN.
5. DEMO HOT WATER EXPANSION TANK (ET-1).
6. EACH ITEM OF EQUIPMENT SHOWN TO BE DEMOLISHED SHALL HAVE ITS ASSOCIATED ELECTRICAL CIRCUITRY REMOVED BACK TO THE PROTECTIVE DEVICE IN THE PANEL. THE PROTECTIVE DEVICE SHALL REMAIN AS AN INTEGRAL PART OF THE EXISTING PANEL AN D SHALL BE RE-LABELED TO ITS NEW FUNCTION OR LABELED AS SPARE IF IT IS NOT RE-USED.
7. DEMO THE EXISTING HVAC CONTROL SYSTEM IN THE MECH. ROOM AND ALL ASSOCIATED CONTROL COMPONENTS (RELAYS, CURRENT SENSORS, TEMP. SENSORS, ETC ... ).
8. DEMO EXISTING MAKE-UP WATER STATION AND EXISTING BACKFLOW PREVENTER SYSTEM .
9. DEMO THE WALL INSIDE THE MECHAN ICAL ROOM AS SHOWN. DEMO THE RETURN DUCT INSIDE THE WALL.
KEY NOTES:
G
DOMESTIC WATER HEATER TO REMAIN
HW BOILER DISCONNECT TO REMAIN
AIR HANDLER DISCONNECT TO BE DEMO'D
CONDENSER DISCONNECT TO BE DEMO'D
I-LON 600 AND CONTROL PANEL TO REMAIN
DEMO EXISTING THERMOSTAT AND HVAC
CONTROL SWITCH IN OFFICE AREA
DEMO WALL APPROX. 11' WIDE X 12' HIGH.
MAKE-UP WATER & BACKFLOW PREVENTER
SYSTEM TO BE DEMO'D
DEMO THE RETURN DUCT INSIDE THE WALL.
EQUIPMENT LIST
NO. DESCRIPTION
ACC-1 AIR COLD CONDENSER
AH U-1 AIR CONDITIONING UNIT
B-1 BOILER
ET-1 EXPANSION TANK
HC-1 HEATING COIL
HC-2 HEATING COIL
HC-3 HEATING COIL
HC-4 HEATING COIL
WH-1 WATER HEATER
- - HWR -
- - HWS - -
·---CD---- --CD--- ·
--- GAS ---
ll ____ J
FD~
LEGEND:
EXISTING CONDENSER RETURN LINE
EXISTING CONDENSER SUPPLY LINE
EXISTING HEATING WATER RETURN LINE
EXISTING HEATING WATER SUPPLY LINE
EXISTING CONDENSATE DRAIN LINE
EXISTING GAS LINE
EXISTING ABANDON GAS LINE
AIR FLOW DIRECTION
EXISTING THERMOSTAT
EXISTING ELECTRICAL PANEL WITH 3' CLEARANCE
SPACE - FRONT OF PANEL
EXISTING FLOOR DRAIN
- ·-··-··-··-"' J
I )
~ ~;L~~2~~;.10N PLAN - ENLARGED MECHANICAL 0--~2 ~~4--6
L .7 '-!.!./ SCALE (FEET)
~KEYPLAN
I I I I I w I C/)
Cf)
I w
::s a_ w 0::::
it'.
w
~ z f- I
WQ:'.
....,O'.l 0 <( D:'. .
0.. <(
Bldg. No.
"' 0 z
"'"' o~ - 'O I
.Q> Ill "' <( " . 0 <(
CA093390P
Project No.
SHEET
REFERENCE
NUMBER
D
" 0
,,,' c:
~3 u::
G I ,._ "' "' <ii cl.
" e 0..
6 z ti'.
w w z (3 z w G
~I z 4
A
•11•11•11•11• I
~----1
I I
EXISTING I
COMPRESSOR 1
I
PAD I
I I L----
[ff]
B
AC
KITCHEN
02D
FD
~--~--~--~~-~~r I
~ '© WALK II 1 1 I
IN LJ
COOLER ----i [JD I ffi[J
~--- DOD ,, I 1 ' / ________ I \ I
FD '\JJ SNACK BAR FD
13~0 I~=~ - - 1-;~~ 1-~-(-10_1 :J - - -~1 ;M
DINING
OQD
M M 101A 102
..... Ml•••••••••••• ll'ff'• • • • • • • • • .n• • • • • • • • • • • • ~ MATCHLINE - SEE M-101B c D
: EXISTING )
CONDENSING ~
UNIT ~
~------- l I
•-GAS - - - - GAS - - - - - - - - GAS -
I . DU DU
FD~
MECH ROOM
I IJ]QJ 1]§2]
~•~ ~- ~ -~~~~~~S~E
I I I I
I I
GD _,;1.12 1 ~
• --~r-- 1 :1
I I
I I ,.
SALES ii
OQD 111
I I I I I I I I
STORAGE
<f> ~~f:~t=~ ·ICAL PLAN - AREA A 0---4~~S8 iiiiiiiiiiiiiiiiiiil12 \fl7 SCALE (FEET)
E F
GENERAL NOTES:
1. INSTALL NEW SUPPLY AIR DIFFUSSERS I REGISTERS AND RETURN AIR
GRILLES WITH BALANCING DAMPERS.
2. INSTALL NEW EXHAUST FANS (EF-4 &5), DUCTWORK AND EXHAUST
GRILLES. SEE EXHAUST FAN SCHEDULE FOR DETAILS.
3. UTILIZE EXISTING ROOF OPENING FOR INSTALLATION OF NEW ROOF
MOUNTED EXHAUST FANS. (EF-4 &EF5)
4. INSTALL NEW THERMOSTAT FOR EACH ZONE AS SHOWN (PROVIDE
NEW CONDUIT AND W IRING).
5. PROVIDE NEW MOISTURE RESISTANT GYPSUM BOARD AT RESTROOMS CEILINGS.
6. UPON COMPLETION OF INSTALLATION, PROVIDE TAB FOR AIR FLOW AS SHOWN.
KEY NOTES:
NEW THERMOSTAT (LABEL AST-ZONE 1)
NEW THERMOSTAT (LABEL AST-ZONE 3)
NEW C02 SENSOR
HWR
HWS
-- --CD---- --CD---
___ GAS ---
ll ____ J
~-J
D
FD~
EQUIPMENT LIST
NO. DESCRIPTION
AC-1 AIR CONDITION
AC-2 AIR CONDITION
EF-1 EXHAUST FAN
EF-2 EXHAUST FAN
EF-3 EXHAUST FAN
EF-4 NEW EXHAUST FAN
EF-5 NEW EXHAUST FAN
SF-1 SUPPLY FAN
LEGEND:
EXISTING CONDENSER RETURN LINE
EXISTING CONDENSER SUPPLY LINE
EXISTING HEATING WATER RETURN LINE
EXISTING HEATING WATER SUPPLY LINE
EXISTING CONDENSATE DRAIN LINE
EXISTING GAS LINE
EXISTING ABANDON GAS LINE
NEW 2' X 2' SUPPLY AIR DIFFUSER
NEW 2' X 2' RETURN AIR DIFFUSER
AI R FLOW DIRECTION
NEW THERMOSTAT
EXISTING ELECTRICAL PANEL WITH 3' CLEARANCE
SPAC E - FRONT OF PANEL
EXISTING EXHAUST FAN
EXISTING 18" VENT - OUTSIDE AIR INTAKE
EXISTING FLOOR DRAIN
~KEYPLAN
s1-1,__ ........................................................................................................................................................................................ ...., ............................................................................................................................................................................................. ...., w I C/)
Cf)
I w
::s a_ w 0::::
z ....J a_ ....J <( Ow zo::::
I w
Bldg. No.
CA093390P
Project No.
SHEET
REFERENCE
NUMBER
M 101A
"O
"' 0
~ c "' " 0
I
"' c
~3 u::
G I ,._ O")
"' <ii 0..
"' O") O")
"' 0 y u·
0..
I
6 z ti'.
w w z (3 z w G
I z lJd
O") s
A I B I c I D I
· · ·- .. - .. -.............. ,.. .. - .. - .. - .. -· i-:::__·_ :__~ ~"_ - - _~/~A- -I -------,.-
: - - - - - - - - - - =--7 4-~ I
• • • • • 1 • • • • • • •.u•u •..•..• "111H1~1•\tiii'i.~i~~:.1• ~!11 • • • • • • • • • • • • • • • • •··"' • • • • • •t. ;
1----~" ~ n •11•11•11•11•11•11•1fi:"'
DINING
I I I I o;:J
I I l1fili] ~
JF~\
~ I "--= I I I
~ 14~01 14~01 '----~-~:--------'
..L 6 __,---- [~] _______ DWJ_ _ I J H_ _ ,----,,--~- ----,I .
l ____ ~_J_Q _[_J._ __ -:-_____ _J~g ____ :-________ ::: _.__~
I I I I I
I I I I I I I I
G(ME:Ot 1 8
1 1 1 I I
-t:J
1 3~0 1 ~ ' ~--~------~-~~ II ..-'~"'-..----------t:.1 -:.-:.-:.-:.-:.-:.-:.-:.-:.-:.-:.-:.-:.-:.~:~1: ---~
''-., HALL 1
NJQD
t I
UP
UP- -up tt __ j
<f> ~~f:~t=~ ·ICAL PLAN - AREA B 0---4~~S8 iiiiiiiiiiiiiiiiiiil12 \fl7 SCALE (FEET)
I I I I
E I F
GENERAL NOTES:
1. INSTALL NEW SUPPLY AIR DIFFUSSERS/REGISTERS AND RETURN AIR GRILLES
WITH BALANCING DAMPERS.
2. UPON COMPLETION OF INSTALLATION, PROVIDE TAB (TEST AIR AND BALANCE)
FOR AIRFLOW AS SHOWN.
KEY NOTES:
0 NEW THERMOSTAT (LABEL AST-ZONE 2)
0 NEW C02 SENSOR
- - HWR -
- - HWS - -
·---CD------CD---
___ GAS ---
ll ____ J
~:=<1 ~-J
D
FD~
LEGEND:
EXISTING CONDENSER WATER RETURN LINE
EXISTING CONDENSER WATER SUPPLY LINE
EXISTING HEATING WATER RETURN LINE
EXISTING HEATING WATER SUPPLY LINE
EXISTING CONDENSATE DRAIN LINE
EXISTING GAS LINE
EXISTING ABAN DON GAS LINE
NEW 2' X 2' SUPPLY AIR DIFFUSER
NEW 2' X 2' RETURN AI R DIFFUSER
AIR FLOW DIRECTION
NEW THERMOSTAT
EXISTING ELECTRICAL PANEL WITH 3' CLEARANCE
SPACE - FRONT OF PAN EL
EXISTING EXHAUST FAN
EXISTING 18" VENT- OUTSIDE AIR INTAKE
EXISTING FLOOR DRAIN
,,.-··--· .. - ·-··-··-··-"!II J
I )
~KEYPLAN
I w I- Cf)
Cf)
I w ...J a..
w 0:::
it'.
w
~ z f- I
WQ:'.
., "' 0 <( D:'. .
0.. <( z ...J a..
"' 0 z
"'"' o~ - "O I
.Q> Ill "' <( " . 0 <(
...J ca Ow z 0:::
I w
Bldg. No.
CA093390P
Project No.
SHEET
REFERENCE
NUMBER
M
A I
N
~ c "' " 0
I
"' c
~3 u::
G I ,.._
"' "' <ii 0..
"' "' "' "' 0 y u·
0..
I
6 z ti'.
w w z (3 z w G
I z lJd
"' N s
I
B I c I
~ I
~7 lC15J
- t
STORAGE
O}D ~i--r=-=rn~:;J--,, ~ ~,_) __ ] U i----- ~I ' . ; --
.....-------' ~ : I I -
IHW1 ~I ~ WECH ROOM -
~ ~ - ~ 1<2> / /~ IV r\11 r\11 M I 1~/ -_ I _ -
II\ ~ ~ 1/\1 26"X 12"-
f--- 8 x 12" 1
-! I -x +n x I._ __ ~--ri----r--__,I I I I j I
W-1 t I~~
,, t;)
··---rm~i.-- ----
H--t'T"
'\})Q
~~t-----
STORAGE
~E GD
I I I I I 'I '----+-----~1-----:::::::;fl:::::ic::±t====::::F=====±-------i
I .
2 4 6 ~ ENLARGED MECHANICAL PLAN °
'°~•~SCALE: 1/2" = 1' ·--·S·C~A~L~E~(F~E~E~Tm)iiiiiiiiiiiiiiiiiijj
I I
D I E I F
NOTES:
1.
2.
2.
3.
4.
5.
6.
7.
8.
FIELD VERIFY EXISTING SITE CONDITIONS PRIOR TO CONSTRUCTION AND BEFORE ORDERING EQUIPMENT.
INSTALL NEW MULTI ZONE AIR HAN DLING UNIT (AHU-1) WITH VFD AN D H-0-F SWITCH. AH U-1 SHALL BE PLACED
ON NEW CONCRETE PAD.
INSTALL NEW SUPPLY, RETURN AND OUTSIDE AI R DUCTS IN THE MECH. ROOM AND CONNECT TO EXISTING
DUCTWORK AS SHOWN. ALL DUCTWORK SHALL BE INSULATED AS PER SPECS.
INSTALL NEW CHILLED WATER SYSTEM TO INCLUDE NEW AIR COOLED CHILLER WITH PUMP AND CHILLED WATER EXPANSION TANK AS FACTORY ASSEMBLED PACKAGE. PROVIDE PUMP WITH ELECTRIC HEATER AND
INSULATED EXPANSION TANK .
INSTALL NEW CHILLED WATER PIPING, AIR SEPARATOR , CHILLED WATER FEEDER, BUFFER TANK AND ALL ASSOCIATED ACCESSORIES AS SHOW ON M-501. ALL CHILLED WATER PIPING SHALL BE INSULATED PER SPECS.
EXTERIOR CHILLED WATER PIPING SHALL BE PROVIDED WITH HEAT TRACE WIRING, INSULATION AND ALUMINUM
JACKETING.
INSTALL NEW HEATING HOT WATER SYSTEM AND CONNECT TO THE EXISTING HOT WATER BOILER. INSTALL
NEW HOT WATER PIPING AS SHOWN ON M-502 AND INSULATE PER SPECS.
INSTALL NEW HOT WATER PUMP (HWP-1) WITH VFD AND H-0-F SWITCH.
INSTALL NEW HOT WATER FEEDER, EXPANSION TANK AND HYDRONIC SEPARATOR.
UPON COMPLETION OF INSTALLATION, PROVIDE TAB FOR AIR FLOW AN D WATER FLOW OF NEW EQUIPMENT.
KEY NOTES:
NEW 24" X 12" OUTSIDE AIR INTAKE DUCT WITH HOOD AND
BIRD SCREEN. (SAW CUT THE EXISTING ROOF FOR DUCT PENETRATION)
POINT OF CONNECTION TO THE MAIN COLD WATER LINE.
AHU-1 VFD AN D H-0-F SWITCH.
NEW DOC CONTROL PAN EL WITH DISPLAY
EXISTING I-LON 600 W/ PAN EL TO REMAIN
NEW CHILLER DISCONNECT SWITCH.
DICONNECT AND RECONNECT BOILER TO EXISTING GAS
LINE AN D TO EXISTING FLUE STACK.
BUILD BACK THE RETURN DUCT TO MATCH EXISTING .
EQUIPMENT LIST
NO. DESCRIPTION
ACC-1 AIR COOLED CHILLER
AHU-1 AIR HANDLING UNIT
B-1 BOILER
ET-1 EXPANSION TANK-BOILER
ET-2 EXPANSION TANK-CHILLER
HWP-1 HOT WATER PUMP
CWP-1 CHILLED WATER PUMP
BT-1 CHILLED WATER BUFFER TANK
WH-1 WATER HEATER
HS-1 HYDRONIC SEPARATOR- HOT WATER
AS-1 CHILLED WATER AIR SEPARATOR
F-1 HOT WATER FEEDER
F-2 CHILLED WATER FEEDER
I
--- GAS ---
ll ____ J
FD~
LEGEND:
EXISTING DUCTWORK
NEW DUCTWORK
EXISTING ITEM I EQUIPMENT
NEW ITEM I EQUIPMENT
EXISTING GAS LINE
EXISTING ABANDON GAS LINE
AIR FLOW DIRECTION
EXISTING THERMOSTAT
EXISTING ELECTRICAL PANEL WITH 3' CLEARANCE
SPACE - FRONT OF PANEL
EXISTING FLOOR DRAIN
- ·-··-··-··-"' J
I )
~KEYPLAN
I w I- Cf)
Cf)
I w ....J a..
w 0::
it'.
w
~ z f--I
WQ:'.
....,O'.l 0 <( D:'. .
0.. <(
"' 0 z
"'"' o~ - ,, I
.Q> Ill "' <( " . 0 <( z ....J oa..
W....J (.9 <( 0::0 ....Jz z<C wI w
Bldg. No.
CA093390P
Project No.
SHEET
REFERENCE
NUMBER
M
"O
~ c "' Q)
I
"' c
~3 u::
G I O") a>
<ii Q_ a> O") O") a> y u·
Q_ I
6 z ti'.
w w z (3 z w G
I z lJd
"' O")
O")
"' a> s
A I
NEW CHILLER
B
MECHANICAL ROOM\
EXTERIOR WALL \
FACTORY SUPPLIED\
t ! ~A I - I I ~I
I c
-- :c 'u~-_. ~7 'i' :
~ ! ~ -~I I f 2 1/2" 121 - ~ I I ~ I G',:1/2"1211
I D I E I F
GENERAL NOTES:
1. PROVIDE HEAT-TRACE WIRING, INSULATION, AND ALUMINUM JACKETING ON ALL EXTERIOR CHILLED-WATER PIPING.
2. THIS DRAWING IS DIAGRAMMATICAL. CONTRACTOR SHALL INSTALL ALL NEW EQUIPMENT AND PIPING SO AS TO
MAINTAIN CLEARANCES AROUND ELECTRICAL EQUIPMENT, FIRE ALARMS, ETC.
3. INSULATE ALL NEW PIPING AND ACCESSORIES PER SPECS.
4. ISOLATION VALVES SIZE 2" AND UP SHALL BE INSTALLED WITH BUTTERFLY VALVES, ISOLATION VALVES SIZE UNDER 2"
SHALL BE INSTALLED WITH GATE OR BALL VALVES.
KEY NOTES:
G
NEW AIR SEPARATOR, SUSPENDED FROM STRUCTURE.
NEW CHW BUFFER TANK
NEW CHW CHEMICAL FEEDER
NEW MAKE-UP WATER LINE (INCLUDING PRESSURE RELIEF VALVE, PRESSURE REDUCING VALVE AND ISOLATION VALVES)
NEW BACKFLOW PREVENTER, 3/4" SIZE FOR CHILLED WATER SYSTEM (INSTALL PER SPECS)
NEW AIR COOLED CHILLER WITH FACTORY INSTALLED HYDRONIC PACKAGE (INCLUDING NEW CHW PUMP W/ VSD, EXPANSION TANK, STRAINER W/ BLOW DOWN VALVE, AIR VENT VALVES, PIT PLUGS, FLOW SWITCH, BALANCING VALVE W/
DRAIN PLUG, CHECK VALVE)
PROVIDE NEW CHW PUMP WITH ELECTRIC HEATER
RUN TO NEAREST FLOOR DRAIN.
LEGEND
[><] ISOLATION VALVE
N CHECK VALVE
~ STRAINER
IXXI BALANCING VALVE
!i PRESSURE RELIEF VALVE c::J<J PRESSURE REDUCING VALVE
1' AIR VENT
i PIT PLUG
NEWAHU-1 ' THERMOMETER
<? PRESSURE GAUGE
-1lr UNION L
0 AUTOMATIC AIR VENT
' ' - FLEXIBLE CONNECTOR
r:::::.ivi RPZ W/ AIR GAP ' ':8
I-t*:i 2-WAY CONTROL VALVE c!:i 3-WAY CONTROL VALVE l.__~~~--~--111--< ___ ~---~---~---~---~---+-~~~~~~-t~~~t:::l-~--L'~~~.~f---2-1_12_"121~~~~~~--1~ ~~~~-+---o~--+-~~----< rT '----~--r.L~-.. L.: __ r:C><l-1---~-----'
~IH
I . .. . . . . . . I I • . • • . • I
NEW 6" HIGH CONCRETE PAD_/ PIPING THROUGH
_/ ~W 4" HIGH CONCRETE PAD_/ NEW 6" HIGH CONCRETE PAD_/
SEAL AND PATCH WALL
f1\ CHILLED WATER PIPING DIAGRAM
~ NOT TO SCALE
I I I I I w I C/)
Cf)
I w
::s a..
w 0::::
it'.
w
~ z f- I
WQ:'.
"""'O'.l 0 <( D:'. .
Q_ <(
(.9 z a..
"' 0 z
"' a> o~ - "O I
.Q> Ill "' <( Q) • 0 <( a..
o::::~ W<( I- c::
<((_9 S<( oo w _J _J
I
Bldg. No.
CA093390P
Project No.
SHEET
REFERENCE
M-501
"O N
~ c "' " 0
I
"' c
~3 u::
G I ,._ O")
"' <ii 0..
"' O") O")
"' 0 y u·
0..
I
6 z ti'.
w w z (3 z w G
I z lJd
" O") s
I
B
NEW HYDRONIC SEPARATOR
WI AUTOMATIC AIR VENT
SUSPENDED FROM
STRUCTURE
I c r314"0 I
I D t '
ET-1
I E I F
GENERAL NOTES:
1. ALL PIPING SHALL BE FULL SIZE UNLESS OTHERWISE NOTED.
2. THIS DRAWING IS DIAGRAMMATICAL. CONTRACTOR SHALL INSTALL ALL NEW EQUIPMENT AND PIPING SO AS TO
MAINTAIN CLEARANCES AROUND ELECTRICAL EQUIPMENT, FIRE ALARMS , ETC.
3. INSTALL NEW HW HYDONIC PIPING AND EQUIPMENT AS SHOWN. INSULATE ALL NEW PIPING AND EQUIPMENT PER SPECS.
4. ISOLATION VALVES SIZE 2" AND UP SHALL BE INSTALLED WITH BUTTERFLY VALVES, ISOLATION VALVES SIZE UNDER 2"
SHALL BE INSTALLED WITH GATE OR BALL VALVES.
314"0 LEGEND
l t><l ISOLATION VALVE
'N CHECK VALVE
----~'-+---+---------;It- -11r--~-_, (I l)l
~ NEW HW EXPANSION
TANK SUSPENDED FROM
STRUCTURE
~ STRAINER
IXXl BALANCING VALVE
NEWHW
FEEDER
+ii .r::::::J
LJ
NEW HW PUMP--». , \
HWP-1 cr
NEW 4" HIGH CONRETE _j
PAD
I
F-1 '1----11
Ir
\_SUCTION DIFFUSER WI
STRAINER VALVE,
NIPPLE AND CAP
I
2"0\ r2"0
[I I I 9...,10
\ 11
' 11
EXISTING BOILER
() B-1 r:,11
EXISTING CIRC.
PUMP
I I
TO NEAREST _j EXIST. CONCRETE _j
FLOOR DRAIN PAD TO REMAIN
f1\ HOT WATER PIPING DIAGRAM
~ NOT TO SCALE
I r NEW 314" BACKFLOW
PREVENTER FOR HOT
WATER SYSTEM
TIE-IN POINT
r EXISTING GAS LINE
\_ NEW FLEX GAS LINE
WI SHUT OFF VALVE
CONNECT TO EXIST.
GAS LINE
I
!i cKJ
'f 'j'
--111-
0 -
Di<J
I
PRESSURE RELIEF VALVE
PRESSURE REDUCING VALVE
AIR VENT
PIT PLUG
THERMOMETER
PRESSURE GAUGE
UNION
AUTOMATIC AIR VENT
FLEXIBLE CONNECTOR
RPZ WI AIR GAP
2-WAY CONTROL VALVE
3-WAY CONTROL VALVE
w I- Cf)
Cf)
I w _J
0...
w n::
it'.
w
~ z I- I
WQ:'.
--,0'.l 0 <( D:'. .
0.. <(
(,9 z -0...
"' 0 z
"'"' o~ - "O I
.Q> Ill "' <( " . 0 <(
0... ~ n:: <( wll'.:'.
1-<.9 <(<( so I- I
Bldg. No.
CA093390P
Project No.
SHEET
REFERENCE
M-502
Q) c
~3 u::
G I "' a>
<ii cl.
a>
"' "' a>
Q) e Q_
6 z ti'.
w w z (3 z w G
~I z 4 lJd
M M 503 503
M M
503 503
A
OFFSET
NOTE:
USE SCREWED TYPE CONNECTION FOR
PIPE FITTINGS.
CONDENSATE DRAIN DETAIL TYP.
NOTTO SCALE
EQUIPMENT DIMENSIONS
AN D BOLT-HOLE LOCATIONS
2"
B
VARIES
CONCRETE EQUIPMENT PAD. W/
#4 BAR AT 12" 0.C. BOTH WAYS
CONCRETE PAD DETAIL
NOTTO SCALE
c
SECURE FAN TO ROOF CURB
USING SHEETMETAL SCREWS,
MINI. 2 SCREWS PER SIDE,
MAX. SPACING 24" O.C.
BUil T UP ROOF
FLASHING AN D COUNTER
FLASHING
DUCT SIZE AS INDICATED
D
DISCONNECTSWITCH
GALVANIZED BIRD SCREEN
RUBBER MOUNTING
2" X 4" CONTINUOUS BLOCKING
FACTORY FABRICATED
INSULATED ROOF CURB
ROOF DECK
FLEXIBLE CONNECTION
AUTOMATIC (BAROMETRIC) BACKDRAFT DAM PER
2 TYP. ROOF EXHAUST FAN DETAIL EF-3 & 4
I
M M
01 503 NOTTO SCALE
P/TPLUG1 L '"""00"~""
• ~ C-H~ CONTROL VALVE
v; ~ ...... v
L l:OLATION VA
'!.:. BALANCING VALVE
c;::i ~ x
.. THERMOMETER _j As:AINER wt DRAIN
VALVE&CAP
5 TYP. CHILLED WATER COIL PIPING DETAILS
M M
503 503 NOTTO SCALE
c;::i
Q z .rm 2-WAY MODULATING
- • ~ H~ ~ONTROL VALVE
~ :x v ...... - v ....., ~ I I -v" s TYP. HOT WATER COIL PIPING DETAILS s~J dtJ NOT TO SCALE
HWR
LVE
HWS
HWR
HWS
E
EXIST. BRANCH DUCT
(REFER TO PLAN FOR
SIZE)
T-BAR
CLG. TILE
SUPPLY AIR DIFFUSER/ GRILLE
EXHAUST W/ ADJUSTABLE
MANUAL VOLUME DAM PER
F
FLEXIBLE DUCT (INSTALL IF NEEDED
TO RECONNECT NEW DIFFUSER/
GRILLES)
S.S. SCREW CLAMP (TYP.)
3 TYPICAL DIFFUSER/GRILLE CONNECTION
M M
503 503 NOTTO SCALE
S.A.
R.A.
M M
102 503
30" X 48"RETURN
AIR PLENUM
FLEX
36" X 24"GALVANIZED
O.A. HOOD WI BIRD
SCREEN
FLASHING & COUNTER
FLASHING
16" x 28"
FLEX
CONNECTION
16" x 18"
CONNECTION 4" CONG. PAD
AHU-1 SIDE VIEW DETAIL
NOTTO SCALE
w I C/)
Cf)
I w
::s a_ w 0::::
it'.
w
~ z
"' 0 z
"' a> o~ f--I
WQ:'.
....,O'.l 0 <( D:'. .
Q_ <(
'O I Q) <( c D:'.
.Q> a::i "' <( Q) • 0 <(
Cf) ....J w ....J z I w
Bldg. No.
CA093390P
Project No .
SHEET
REFERENCE
M-503
6 z ti'.
w w z (3 z w G in
I z 4 lJd a>
A I B I c I D I E I F
NEW AIR HANDLING UNIT SCHEDULE (AHU-1)
MARK
AHU-1
NOTES:
TYPE
MULTI-ZONE
TOTAL AIRFLOW
(CFM)
FAN DATA
OUTSIDE "XT. STATIC
AIRFLOW PRESSURE
(CFM) (IN W.C.)
1750 1.5
MIN
FAN HP
ELEC. DATA
V/PH/HZ
208-230 I 3 I 60
TOTAL
CAPACITY
(MBH)
1. VERIFY UNIT IS COMPATABLE WITH EXISTING MECHANICAL ROOM SPACE AND CONDITIONS PRIOR TO ORDERING.
2. VERIFY AND MAKE SURE THAT AIR HANDLER HEATING COIL IS COMPATABLE WITH THE EXISTING BOILER.
3. PROVIDE UNIT WITH VARIABLE-FREQUENCY DRIVE AND H-0-A SWITCH.
EAT
(oF)
AIR
HEATING COIL DATA
LAT
(oF)
EWT
(oF)
4. PROVIDE UNIT WITH 2" DOUBLE-WALL, R-13 INJECTED FOAM ISULATION, GALVANIZED STEEL CONTRUCTION WITH HINGED ACCESS DOORS.
5. PROVIDE FILTER SECTION WITH HINGED ACCESS DOOR.
6. COOLING COIL SHALL HAVE A STAINLESS STEEL COIL CASING AND A DRAIN PAN.
MARK
CH-1
NOTES:
NEW AIR-COOLED CHILLER SCHEDULE
CAPACITY AMBIENT MIN. NUMBER
(TONS) AIR TEMP OF
(°F) COMPRESSORS
26 95 2
GPM
WATER
EWT
(oF)
LWT
(oF)
ELEC. DATA
VI PH / HZ
208-230 I 3 I 60
MIN EER
1.
2.
3.
4.
5.
6.
7.
PROVIDE UNIT WITH FACTORY MOUNTED FLOW SWITCH, CHILLED WATER PUMP AND EXPANSION TANK AS SHOWN ON M-501.
PROVIDE UNIT WITH HOT GAS BYPASS.
PROVIDE UNIT WITH LONWORKS INTERFACE CARD
PROVIDE UNIT WITH FULL HAIL GUARDS.
PROVIDE UNIT WITH A SINGLE-POINT POWER CONNECTION.
MINIMUM EER LISTED IS AT AHRI CONDITIONS.
PROVIDE UNIT EQUIVALENT TO CARRIER -AQUASNAP MODELE 30RAP CHILLER.
WATER
LWT
(oF)
GPM
MARK
CWP-1
HWP-1
NOTES:
CAPACITY
(MBH)
TOTAL SENSIBLE
320 230
SYSTEM
COOLING COIL
HEATING COIL
COOLING COIL DATA
EAT
(oF)
AIR
DB I WB
82 I 67
GPM
LAT
(oF)
DB I WB
EWT
(oF)
WATER
LWT
(oF)
NEW PUMP SCHEDULE
HEAD
(FT)
RPM
MOTOR
HP
1/2
1. PROVIDE UNIT WITH PREMIUM, HIGH-EFFICIENCY MOTOR.
GPM
FILTER DATA
TYPE
2" PLEATED (MERV 8)
ELEC. DATA
V / PH I HZ
208-230 I 3 I 60
208-230 I 3 I 60
2. PROVIDE UNIT WITH HAND-OFF-AUTO SWITCH AND MOUNT ON THE WALL INSIDE THE MECH. ROOM.
3. PROVIDE UNIT WITH VARIABLE-FREQUENCY DRIVE AND HAND-OFF-AUTO SWITCH.
NOTES
1, 2
1, 3
EXISTING HOT WATER BOILER SCHEDULE FOR REFERENCE ONLY NEW EXPANSION TANK SCHEDULE NEW CHILLED WATER BUFFER TANK SCHEDULE
MARK
B-1
NOTES:
CAPACITY
OUTPUT
(MBH)
MIN
EFFICIENCY
(%) GPM
1. BOILER'S IN-LINE CIRCULATING PUMP TO REMAIN.
WATER
EWT
(°F)
LWT
(°F)
ELEC. DATA
V/ PH / HZ
208-230 I 3 I 60
SYMBOL SYSTEM
ET-1 HEATING
ET-2 COOLING
NOTES:
TYPE
BLADDER
FACTORY
SUPPLIED
MAX
PRESSURE
(PSI)
VOLUME
(GAL)
1. INSTALL TANK IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
NOTES
1, 2, 3
1, 2, 3
MARK SYSTEM TYPE
BT-1 CHILLED-WATER BLADDER
MAX
PRESSURE
(PSI)
VOLUME
(GAL)
NOTES:
1.
2.
3.
INSTALL TANK IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
INSTALL TANK WITH INTERNAL BAFFLES, AIR VENT VALVE, AND DRAIN.
INSTALL TANK WITH INSULATION AND WRAP WITH ALUMINUM JACKET.
2. BOILER SHALL BE RE-INSTALLED WITH HYDRONIC PIPING AND EQUIPMENT AS SHOWN ON M-502. 2. INSTALL TANK WITH INSULATION AND WRAP WITH ALUMINUM JACKET.
3. TANK SHALL BE PRE-CHARGED TO 30 PSI.
MARK
AS-1
AIR SEPARATOR SCHEDULE
SYSTEM GPM
CHILLED WATER 64
MAX
PRESSURE
(PSI)
INLET/
OUTLET
SIZE
21/2"
NOTES:
1.
2.
INSTALL UNIT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
INSTALL UNIT WITH INSULATION AND WRAP WITH ALUMINUM JACKET.
NOTES
1, 2, 3
MARK
HS-1
HYDRONIC SEPARATOR SCHEDULE
SYSTEM GPM
HOT WATER 24
MAX
PRESSURE
(PSI)
INLET/
OUTLET
SIZE
2"
NOTES:
1.
2.
INSTALL UNIT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
INSTALL UNIT WITH INSULATION AN D WRAP WITH ALUMINUM JACKET.
NOTES
1, 2, 3 s...., ..... _______________________________________ .....-----------------------------------------.---------------------------------------...... ----------------------------------------.----------------------------------------~.-----------------------------------------1 w 1- (j)
(j)
I w
::s a_ w 0::::
"' 0 z it'.
w
"' a> o~ -z f- I
WQ:'.
....,O'.l 0 <( D:'. .
Q_ <(
'O I
.Q> Ill "' <( Q) • 0 <(
"I"""" I w
...J w I u (j)
...J u z I u w
Bldg. No.
CA093390P
Project No.
SHEET
REFERENCE
M-601 c
N 'I' c g
"' Q)
I
"' c
~3 u::
G I "' a>
<ii cl.
u· a.
I
6 z ti'.
w w z (3 z w G in l'J z lJd l'J
I
A I B I
NEW EXHAUST FAN SCHEDULE
STATIC
MARK CFM PRESSURE RPM
MOTOR ELEC. DATA
NOTES
(INW.C.)
HP VI PH I HZ
EF-3 150 0.125 1200 1/100 115 / 1 /60 1, 2, 3
EF-4 300 0.15 1750 1/30 115 / 1 /60 1, 2, 3
NOTES:
1. PROVIDE UNIT WITH DIRECT-DRIVE, ROOF-MOUNTED FAN AND HIGH-EFFICIENCY MOTOR.
2. PROVIDE UNIT WITH BACKDRAFT DAMPER, BIRD SCREEN AN D FACTORY MOUNTED SAFETY
DISCONNECT SWITCH.
3. PROVIDE UNIT WITH A SPEED CONTROLLER AN D INTERLOCK WITH THE DOC CONTROL SYSTEM
TO OPERATE CONTINOUSLY DURING OCCUPIED MODE.
-. I c I D I
AIR DEVICE SCHEDULE
~- MARK (SEE SCHEDULE BELOW)
- CFM
SIZE (IN)
MARK CFM RANGE DESCRIPTION
FACE NECK
A 0-300 24x24 10 4-WAY SUPPLY DIFFUSER
B 301 -450 24 x24 12 4-WAY SUPPLY DIFFUSER c 0-200 12 X 12 6 4-WAY SUPPLY DIFFUSER
D 0-450 24 x 12 SIDE WALLS.A. DIFFUSER
E 0-1500 24x24 RETURN AIR GRILLE
F 0-100 12 x 8 RETURN AIR GRILLE
NOTES:
1. PROVIDE UNIT SUITABLE FOR LAY-IN INSTALLATION.
2. PROVIDE SUPPLY DIFFUSER WITH ADJUSTABLE BALANCING DAM PER.
3. PROVIDE SUPPLY DIFFUSER WITH INSULATED BACKPAN. THE INSULATION SHALL
CONSIST OF 1/2" MINI. FIBERGLASS AND FOIL VAPOR BARRIER.
4. PROVIDE SUPPLY, RETURN AND EXHAUST AIR DEVICES IN GYPSUM BOARD CEILING WITH
MOUNTING FRAME SO THAT THEY CAN BE LIFTED OUT FOR ABOVE CEILING ACCESS.
I I
E I F
' '} ~ t ci1
"' 0 c 0 a ·5 "' "' 0
-t
THROW REFERENCE
NOTES "' 0 (FT) MANUFACTURER f- >- ~ ii5c:>_J z I~B
8 1, 2, 3, 4 TITUS-TMSA-AA it'. 27 XO en "' a> wow w o~ l'J ----8 1, 2, 3, 4 TITUS-TMSA-AA ;;;1mgs <( ()Ct'.a_ z
6 2, 3, 4 TITUS-TMSA-AA zOc:t: <( ::;:
~~ Iu_::J ::;: <(
() a. f- I -o I 10 2, 3, 4 w () <(
~~ f- Wet:
....,O'.l .Q> Ill
- 1, 4 TITUS-355RL
0 <( "' <( Ct'. . Q) •
a. <( 0 <(
- 1, 4 - en ~en~ o<S en w:.'.w <( f-Ct'.f- ci x - <(O - 0 w c:t:$:0 N f-
8'28 ~a::w6 ~tl1u.o ()-'I 0~f"'.O.,. wO'.lf-
Q;i5:~ oc:>zI"'!t ....1Z<(j.-'. ~ 0 u_ c:JW(l)LL......_
N I
~ w w _J
I- ::> Cf) 0 >- w Cf) I <( Cf)
> _J I <( w () <( z
- _J <( a_ I w () 0:::: w
Bldg. No.
CA093390P
Project No.
SHEET
REFERENCE
NUMBER
M-602
'O
~ c <I) Q)
I <I) c
~3 u::
G I "' a>
<ii Q_ a>
"' "' a> y u·
Q_ I
6 z ti'.
w w z (3 z w G
I z lJd
"' "' a> s
I B I c
REMOTE TEMPERATURE~
SENSOR CONNECTED r;:;;:;;::i
TO BOILER'S CONTROLS 1- - - - - - - ~ - - - - - - - - - - -I
r----,-------- I .-~------------1 I I I r _Ir -1 I I
~ - $ IVFol [fil ~ ctJ II I I I HWS --1 : i IL- HW PUMP ,-~ - - - - - - - - - -, : ~1-----r-~--il-1-'-+-~~~~~~~~~~~cti~~-I HWR---1
I I ';\___ EXI;;::-CIRC. PUMP
I L ______ _J ENABLED BY BOILER
I CONTROLS
L----------------------------~----------
(1\HEATING HOT WATER SYS. CONTROL DIAGRAM
~N.T.S .
I
EXISTING I-LON 60011
(IN MECH. ROOM) NEW O.A.
0 REMAIN SENSOR
!;1-160 f-z w
I I
[):'.1 50 w
NEW DOC CONTROL
PANEL W/ DISPLAY
(LONWORK
CONTROLLERS) i b I
20 30 40 50 60 70
OUTSIDE AIR TEMPERATURE °F
@HN~~. WATER RESET SCHEDULE
I
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1oocl- - - - - - - - - 1
FLOW SWITCH- TO CHILLER
----------- CONTROL PAN EL ~ - - - - - - 1 DOC I- - - - - - - - -
I ) I
AIR COOLED
CHILLER
FS r*1
CHWS~~~~~~~+-~~~~~~---·
nCH~'u-+r,.,_1P__ ~ ~7 CHWR•~~~~~-ir-~~~~~~---1, T
[fil ~ I n
LI _J L - - - - - - 1 DOC I- - - - - - - - - I
I I
L - - - - - - - - - - - - - - - - - - - 1oocl- - - - - - - - - _J
{3\CHILLED WATER SYS. CONTROL DIAGRAM
~ N.T.S.
I I
I D
[IJ TEMPERATURE SENSOR
[fil EQUIPMENT ENABLE
~ EQUIPMENT STATUS
§] SAFETY FLOW SWITCH
I DOC I DIRECT DIGITAL CONTROL SYS.
0 EQUIPMENT ALARM
@J DAMPER ACTUATOR
0 PRESSURE SENSOR
I VFD I VERIABLE FREQUENCY DRIVE
I
I E I F
GENERA! NOTES·
1. DEMO AND REPLACE THE EXISTING BUILDING CONTROL SYSTEM WITH NEW DOC CONTROL SYSTEM.
ALL SENSORS, RELAYS, CONTROL PANELS, ACTUATORS, CONTROL DAMPERS AND CONTROL VALVES
SHALL BE REPLACED UNLESS OTHERWISE NOTED.
2. FURNISH AN D INSTALL NEW LONWORKS CONTROLLER PROGRAMMED TO ACCOM PLISH THE SEQUENCE OF OPERATIONS. (NEW CONTROLLERS SHALL HAVE THE CAPABILITIES TO MANUALLY OVERRIDE ALL
CONTROLS POINTS)
3. FURNISH AND INSTALL A NEW CONTROL PANEL WITH LONWORKS DISPLAY AND PLACE IN THE MECHANICAL ROOM.
4. EXISTING I-LON 600 ROUTER TO REMAIN , INSTALL A LON TRUNK CONNECTING THE NEW DOC SYSTEM TO THE l-LON600 ROUTER.
5. PROVIDE ALL SENSORS, RELAYS AND OTHER DEVICES THAT ARE NECESSARY TO ACCOMPLISH THE SPECIFIED SEQUENCE OF OPERATION. ALL COMPONENTS OF THE CONTROL SYS. SHALL BE LONWORKS COMPLIANT.
SEO! !ENCE OF OPERATION FOR HEATING AND COOi ING SYSTEMS-
THE DOC SHALL START THE CHILLED WATER AN D HOT WATER SYSTEMS AUTOMATICALLY.
THE SYSTEMS WILL BE STARTED BASED ON THE FOLLOWING SCHEDULE:
INITIAL SCHEDULE:
MONDAY - FRIDAY 0600 TO 1800
SATURDAY OFF
SUNDAY OFF
HOLIDAY OFF
HOT WATER SYSTEM SEQUENCE OF OPERATION
1. THE HOT WATER SYSTEM WILL BE ENABLED WHENEVER THE SCHEDULE IS IN THE
OCCUPIED MODE AND THE OUTSIDE AIR TEMPERATURE IS BELOW 65°F (ADJ). THE SYSTEM
WI LL BE DISABLED WHENEVER THE OUTSIDE AIR TEMPERATURE IS 3°F ABOVE THE HOT
WATER SYSTEM ENABLE SETPOINT. ONCE THE SYSTEM IS ENABLED, THE HOT WATER PUMP
IS STARTED. AFTER THE HOT WATER PUMP CURRENT SENSING RELAY VERIFIES PUMP, THE
BOILER WILL BE ENABLED. BOTH PUMP AND BOILER OPERATE CONTINUOUSLY UNTIL THE
SYSTEM IS DISABLED. ONCE DISABLED THE BOILER WI LL BE DISABLED FIRST AND AFTER
A 5 MINUTE DELAY THE PUMP WILL BE STOPPED.
2. THE BOILER SHALL MAINTAIN BUILDING HOT WATER SUPPLY TEMPERATURE SETPOINT
BASED ON ITS INTERNAL CONTROLS. THE CONTRACTOR SHALL PROVI DE A REMOTE TEMP.
SENSOR TO BE INSTALLED IN THE SUPPLY HOT WATER PIPING. THE SETPOINT IS
DETERMINED BY THE HOT WATER RESET SCHEDULE.
3. VFD SHALL MODULATE THE HW PUMP TO MAINTAIN THE HOT WATER FLOW.
BOILER'S INTERNAL CONTROLS SHALL CONTROL BOILER CIRCULATING PUMP
OPERATION TO MAINTAIN MINIMUM FLOW TO BOILER.
4) NIGHT SETBACK - WHILE IN UNOCCUPIED MODE, THE HOT WATER SYSTEM SHALL BE
ENABLED IF ANY SPACE SENSOR FALLS BELOW 50°F (ADJ.). WHEN TEMPERATURES
INCREASE TO 5°F ABOVE LOW LIMIT SETPOINT, SYSTEM SHALL BE DISABLED.
CHILLED WATER SYSTEM SEQUENCE OF OPERATION
1. THE CHILLED WATER SYSTEM WILL BE ENABLED WHENEVER THE SCHEDULE IS IN THE
OCCUPIED MODE AND THE OUTSIDE AIR TEMPERATURE IS ABOVE 65°F (ADJ). THE SYSTEM
WILL BE DISABLED WHENEVER THE OUTSIDE AIR TEMPERATURE IS 3°F BELOW THE CHILLED
WATER SYSTEM ENABLE SETPOINT. ONCE THE SYSTEM IS ENABLED, THE CHILLED WATER
PUMP IS STARTED. AFTER THE CHILLED WATER PUMP CURRENT SENSING RELAY VERIFIES
PUMP , THE CHILLER WILL BE ENABLED. THE CHILLER MAINTAINS BUILDING CHILLED
WATER SUPPLY TEMPERATURE BASED ON ITS INTERNAL CONTROLS. BOTH PUMP AND CHILLER
OPERATE CONTINUOUSLY UNTIL THE SYSTEM IS DISABLED BY THE SCHEDULE OR THE
OUTSIDE AIR TEMPERATURE IS BELOW THE SETPOINT. ONCE DISABLED THE CHILLER WILL
BE DISABLED FIRST AND AFTER A 5 MINUTE DELAY THE PUMP WILL BE STOPPED.
2. SAFETY- THE CHILLER SHALL BE PROVIDED WITH FLOW SWITCH IN ITS CHILLED WATER
LOOP. THE CHILLER SHALL OPERATE ONLY IF FLOW IS ESTABLISHED.
3) NIGHT SETBACK - WHILE IN UNOCCUPIED MODE, THE CHILLED WATER SYSTEM SHALL
BE ENABLED IF ANY SPACE SENSOR RISES ABOVE 90°F (ADJ .). WHEN TEMPERATURES
DECREASE BACK TO 5°F BELOW HIGH LIMIT SETPOINT, SYSTEM SHALL BE DISABLED.
I I w I C/)
Cf)
I w
::s a..
w 0::
it'.
w
~ z
"' 0 z
"' a> o~ -f- I
WQ:'.
....,O'.l 0 <( D:'. .
Q_ <(
-oI Q) <( co:'.
.Q>CO
<I)<( Q).
0 <(
Cf) ....J 0::
1-z
0::
w ....J ....J
I () -0::
w ....J
Ill
Bldg. No.
CA093390P
Project No.
SHEET
REFERENCE
M-701
"O N I'-
~ c "' " 0
I
"' c
~3 u::
G I I'- O")
"' <ii 0..
"' O") O")
"' 0 y u·
0..
I
6 z ti'.
w w z (3 z w G
I z lJd
" O")
I'-s
A I
SEOl IENCE OF OPERATION ·
1) THE DOC SHALL START THE AHU-1 AUTOMATICALLY.
THE SYSTEMS WILL BE STARTED BASED ON THE FOLLOWING SCHEDULE:
INITIAL SCHEDULE:
MONDAY - FRIDAY 0600 TO 1800
SATURDAY OFF
SUNDAY OFF
HOLIDAY OFF
AHll-1 SFOllFNCF OF OPERATION
B
THE AHU SHALL BE CONTROLLED THRU ITS ON-OFF-AUTOMATIC CONTROL LOCATED ON THE UNIT AND
SHALL BE INTERLOCKED WITH THE DOC CONTROL SYSTEM IN THE BLDG VIA LONWORKS TRUNK.
UNOCCUPIED MODE
1) THE FAN IS STOPPED.
2) THE OUTSIDE AIR DAM PER IS CLOSED
3) THE RETURN AIR DAMPER IS OPEN
4) THE HOT AND CHILLED WATER VALVES ARE CLOSED.
OCCUPIED MODE
1) THE OUTSIDE AND RETURN AIR DAMPERS ARE PLACED IN AUTOMATIC CONTROL.
2) THE SUPPLY FAN IS PLACED IN AUTOMATIC CONTROL.
3) THE HOT WATER VALVE AND THE CHILLED WATER VALVE ARE PLACED IN AUTOMATIC CONTROL.
SUPPLY FAN CONTROL
I
WHEN THE SUPPLY FAN STARTER IS IN THE AUTO POSITION, THE FAN SHALL STOP WHEN THE DOC IS IN THE UNOCCUPIED MODE AND SHALL START WHEN IT IS IN THE OCCUPIED OR NIGHT LOW LIMIT MODES.
WHILE THE SUPPLY FAN IS OFF, AS DETERMINED BY THE SUPPLY FAN STATUS, THE COOLING COIL VALVE AN D THE OUTSIDE AIR DAM PER ARE CLOSED. THE RETURN AIR DAMPER IS OPEN. THE HEATING COIL VALVE IS MODULATED UNDER THE HOT DECK TEMPERATURE CONTROLLER. ZONE DAM PERS SHALL BE UNDER
THE CONTROL OF THEIR ZONE SENSORS.
WHEN THE DOC RECEIVES AN INPUT PROVING THAT THE SUPPLY FAN IS ON, THE CONTROL DAMPERS ARE POSITIONED FOR FULL RECIRCULATION OF AIR. POSITIONED TO INTRODUCE MINIMUM OUTSIDE AIR, OR MODULATED TO MAINTAIN MIXED AIR TEMPERATURE. THE CHILLED AN D HOT WATER VALVES SHALL BE MODULATED UNDER AUTOMATIC CONTROL TO MAINTAIN HOT DECK AND COLD DECK SETPOINTS.ZONE DAMPERS SHALL BE UNDER
THE CONTROL OF THEIR ZONE SENSORS.
THE VFD SHALL MODULATE THE FAN'S SPEED BASED ON DIFF. PRESSURE SENSOR LOCATED IN THE SUPPLY AIR DUCT TO MAINTAIN THE AIR FLOW REQUIRED. THE VFD SHALL BE CONFIGURED SO AS TO PREVENT THE FAN FROM
OPERATING OUTSIDE OF THE MANUFACTURER'S RECOMMENDATED LI MITS.
SAFETIES
1) FREEZE PROTECTION: WHEN THE MIXED AIR TEMPERATURE FALLS BELOW THE SETPOINT OF 38°F (ADJ .) A SET OF NORMALLY CLOSED FREEZE STAT CONTACTS IN THE AHU FAN STARTER SAFETY CIRCUIT WILL OPEN, PREVENTING THE AHU FAN FROM OPERATING. AN ADDITIONAL SET OF NORMALLY OPEN CONTACTS IN THE FREEZE STAT SHALL CLOSE PROVIDING AN ALARM TO THE DOC. A MANUAL RESET AT THE FREEZE STAT IS REQUIRED
TO RESTART THE FAN AND CLEAR THE ALARM.
c I
CONTROi S I EGEND
Ci] TEMPERATURE SENSOR
I DOC I DIRECT DIGITAL CONTROL SYSTEM
0 EQUIPMENT ENABLE
0 EQUIPMENT STATUS
@] FLOW SWITCH
~ DAMPER ACTUATOR
0 FREEZESTAT
@] STATIC PRESSURE SENSOR
I VFD I VARIABLE FREQUENCY DRIVE
0 EQUIPMENT ALARM
I co2 I CARBON DIOXI DE SENSOR
I DOC I I DOC I
~ D
2) SMOKE DETECTOR: WHEN SMOKE IS SENSED IN THE SUPPLY AIR OR RETURN DUCTS BY THE SMOKE DETECTOR(S), A SET OF NORMALLY CLOSED CONTACTS IN THE AHU FAN STARTER CONTROL CIRCUIT WILL OPEN, PREVENTING RETURN ~)I I
NC
THE AHU FAN FROM OPERATING. THE DOC SYSTEM SHALL ALSO SEND AN ALARM SIGNAL TO THE FIRE ALARM SYSTEM
IN THE BUILDING.
INDOOR AIR QUALITY (IAQ):
CONTRACTOR SHALL INSTALL A CARBON DIOXISE SENSOR IN THE OUTSIDE AIR TO ESTABLISH THE BASELINE C02 LEVEL FOR THE IAQ ALERT. CONTRACTOR SHALL ALSO INSTALL C02 SENSORS AND SHALL PLACE ONE IN THE KITCKEN AREA, ONE IN THE DINNING AREA AND ONE IN THE SALES AREA. WHENEVER THE C02 LEVEL IN THE SPACES EXC EEDS THE BASELINE BY 400 PPM AN ALARM SHALL BE INITIATED. THE ALARM SHALL INDICATE WHICH OF THE C02 SENSORS
INDICATED THE ALARM.
NIGHT SETBACK
WHILE IN UNOCCUPIED MODE, IF ANY SPACE SENSOR FALLS BELOW 60 °F(ADJ .) OR ABOVE 90 °F(ADJ.) THE AHU SHALL BE ENABLE. THE AHU SHALL PLACED IN AUTOMATIC CONTROL UNTIL THE SPACE SENSOR REACHES 65°F OR 85°F
RESPECTIVELY.
I I
AIR
I
OUTSIDE
AIR
z
I ctJ I D~C I
D I E I
GENERAi NOTES·
1. DEMO AND REPLACE EXISTING CONTROLS OF THE EXISTING AHU IN THE MECH. ROOM WITH NEW DOC
CONTROL SYSTEM AS SHOWN.
F
2. PROVIDE NEW CONTROLLERS, SENSORS, ACTUATORS, RELAYS AN D OTHER DEVICES THAT ARE NECESSARY TO ACCOMPLISH
THE SPECIFIED SEQUENCE OF OPERATION.
3. ALL COMPONENTS OF THE CONTROL SYSTEM SHALL BE LONWORKS COMPLIANT.
4. INSTALL NEW CHW CONTROL VALVE WITH 3-WAY MODULATING VALVE AND NEW HW CONTROL VALVE WITH 2-WAY MODULATING
VALVE.
5. INSTALL NEW DOC TEMPERATURE SENSORS, ONE FOR EACH ZONE (TOTAL OF 3 ZONES).
6. CONTRACTOR SHALL INSTALL NEW SMOKE DETECTORS ON SUPPLY AND RETURN DUCTS.
7. CONTRACTOR SHALL INSTALL C02 SENSORS FOR MONITORING C02 LEVEL IN THE SPACES AND CONNECT TO THE DOC SYSTEM.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR TA&B. WORK SHALL INCLUDE BALANCING HYDRONIC FLOWS AND AIR FLOWS
FOR THE NEW AHU.
I D~C I
NEW CONTROL PAN EL
WI DISPLAY AND NEW
DOC CONTROLLERS
EXISTING l-LON-600 @J-D D O.A. SENSOR clJ
TT~ TYPICAL ZONE
(/) a::
s s I I DOC I I I DOC
NO 1
E-fr-1
~ I D~C I ~ D
00 I V~D I SP I NO'
H ["'
HOT ,v
1(@~1 ) c n c z SUPPLY FAN c
I DOC I
<fJ a::NC 1 s s I I I
II~
I
SUPPLY
COLD
I
SUPPLY
I D~C I
,v ' r-- ' r--
}"NC
I
TYPICAL ZONE SPACE
TEMPERATURE SENSOR
I
~TOZONE
w I- Cf)
Cf)
I w _J a..
w 0::
it'.
w
~ z f- I Wa::
....,O'.l 0 <( a:: .
0.. <(
"' 0
I'-z
"'"' o~ - "O I " <( ca::
.Q> a::i "' <( " . 0 <(
Cf) _J
0::
I-z u I
Bldg. No.
CA093390P
Project No.
SHEET
REFERENCE
M-702
A I B I c I D
PANEL
TOGGLE SWITCH---, BASE
~ STD NETWORK I ,,,.- SEE NOTE 7
N- SURGE ...- CAT-6 120 {H-a 120 VAC ~ ~· 'DUPLEX VV VAC G- PROTECTOR ~ c:i CABLE
FUSE-~'~~~~-'
TERM-1( \_L.QN_C6_Bh_E~ - -\ \
/ - - - - --._ \\ /- - - - ~(- - - - -,\ I ~RM-2
ILON I I
II 600 ',1 ',1 '1 '1
(BPOC) I LON NODE I I LON NODE I I '°' ',ooe I I '°'' ,oo' I
(SEE NOTE 8) (SEE NOTES
9 AND 10)
LOCATION OF ILON600 SHALL BE WITHIN
120 VAC ?
THE VICINITY OF THE LAN SWITCH
TYPICAL LON BUS - RISER DIAGRAM 1
NODE NODE NODE
f- f- f- f- f- f-w w w w w w z z z z z z
A <;>.... A <;>.... A <;>.... .. I I I I ( I I I ( I I I 0 0 " " 0 0 " " 0 0 " " w w _J _J w w _J _J w w _J _J
D:'. D:'. O'.l O'.l D:'. D:'. O'.l O'.l D:'. D:'. O'.l O'.l
"' 0
~ RED~-- •• ··••···· .. ···· ...• ) [ 1 1 - ..... ···.,···· .. ···-,) [ 1 1 - ..... ···.,···· .. ····,.) [ 1 1 - .. ._. ···.,···· .. ··~ RED ~@ BLK ~ .. .-••.• ·' .. ........ '-..... ::::____=.i-c:x:::x-... · ............... ::::____=.i-c:x:::x-................... ::::____=.i-c:x:::x-................. ~ BLK ~ 4
CD®@
©I TERM
~ c "' " 0
I c
~3
TYPICAL LON BUS - RISER DIAGRAM 2
u::
G I "' a>
<ii Q_ a>
"' "' a> y u·
Q_ I
6 z ti'.
w w z (3 z w G
I z lJd
"' "' "' a> s
I I I
I
I
E I F
GENERAL NOTES:
1. THIS DIAGRAM IS SHOWN AS A "TYPICAL" LON TRUNK TOPOLOGY IN ACCORDANCE WITH
SPECIFICATION 23 09 23.
2. ALL BUILDINGS SHALL BE EQUIPPED WITH ONE LON TRUNK AN D ONE BUILDING POINT OF
CONNECTION (BPOC).
3. END-OF-LINE (EOL) TERMINATORS SHALL BE LOCATED AT THE BUILDING POINT OF
CONNECTION (BPOC), TYPICALLY AN ILON 600, AND AT THE LAST NODE ON THE BUS, AS SHOWN
ON THIS DRAWING.
4. CONTRACTOR SHALL INSTALL AN ILON 600 (BPOC) WITHIN
THE COMM CLOSET OR WITHIN THE VICINITY OF THE LAN SWITCH IN ACCORDANCE WITH
SPECIFICATION 23 09 23. CONTRACTOR SHALL INSTALL ILON 600 (BPOC) (PER SPECIFICATION 23 09 23) MOUNTED IN A LOCKABLE BOX EQUIPPED WITH A CH751 KEY. INSTALL POWER WIRING
TO THE BPOC. THE BPOC SHALL CONNECT TO THE DOC CONTROLS AN D SERVICE METERS.
PROVIDE CAT-6 CABLE FOR FUTURE CONNECTION TO BUILDING LAN SWITCH.
5. THE CONTRACTOR SHALL PROVIDE AN AS-BUILT RISER DIAGRAM THAT INCLUDES
DESCRIPTION OF DEVICES/NODES ALONG WITH THEIR ORDER ON THE LON TRUNK.
6. THE LON TRUNK IS A DOUBLE TERMINATED TP/FT-10 BUS TOPOLOGY.
7. A CAT-6 CABLE SHALL BE PROVIDED FOR CONNECTION OF THE BPOC WHICH NEEDS TO BE
WITHIN THE BUILDING LAN SWITCH. THE CAT-6 SHALL BE LONG ENOUGH TO REACH
THE SWITCH WITH 3 M TO SPARE. THE CABLE SHALL BE CLEARLY LABELED UMCS AT BOTH ENDS.
THE INSTALLER SHALL NOT PLUG THE CAT-6 INTO THE LAN SWITCH.
8. LON NODES (PER SPECIFICATION 23 09 23) ARE DEVICES THAT COMMUNICATE USING THE
CEA-709.1 B PROTOCOL AND ARE CONNECTED TO A CEA-709.1 B NETWORK. LON NODES VARY
DESCRIBED AS DOC CONTROLS AN D SERVICE METERS.
9. DOC LON NODES ARE DEPICTED IN THE MECHANICAL DESIGN DRAWINGS. DOC CONTROLS AND LON CARDS ON EQUIPMENT SUCH AS, BUT NOT LIMITED TO: CHILLERS, BOILERS, COOLING TOWERS, AND THEIR ASSOCIATED PUMPS, VARIOUS HVAC SYSTEM EQUIPMENT (AHUS, FCUS, SENSORS, VAVS, ETC.), AND CONTROL VALVES.
NOTES:
G) DO NOT ROUTE COMMUNICATION WIRE IN CONDUITS CARRYING AC VOLTAGE LINES. DEDICATED
COMMUNICATION RACEWAY IS REQUIRED IN EMT.
@ COMMUNICATION WIRE MUST BE UNSHIELDED EQUAL TO BELDEN 8461 #18 STRANDED SINGLE
TWISTED PAIR AND BE CONSTANT THROUGHOUT LOOP.
@ DOUBLY TERMINATED TOPOLOGY. LON MAXIMUM DISTANCE 2700 M. ILON 600 CONFIGURED AS
REPEATER REQUIRED AFTER 64 NODES.
@ TERMINATORS DEFINE THE PHYSICAL ENDS OF THE LON. THE TERMINATORS ARE 105 OHM
RESISTORS FOR SUPPORTED BUS ARCHITECTURE.
I w I C/)
Cf)
I w
::s a_ w c:::
"' 0 z it'.
w
"' a> o~ -z f- I
WQ:'.
....,O'.l 0 <( D:'. .
Q_ <(
Cf) _J c:::
1-z _J z I w
Bldg. No.
CA093390P
Project No.
SHEET
REFERENCE
M-703
| G-101 Cover Sheet |
| C-101 |
| D-101A |
| D-101B |
| D-102 |
| M-101A |
| M-101B |
| M-102 |
| M-501 |
| M-502 |
| M-503 |
| M-601 |
| M-602 |
| M-701 |
| M-702 |
| M-703 |
File details come from the government source that posted it. Updated .