C-103_Revised_Drawings.pdf
PDF 241 KB Posted
- Attached to
- Replace HVAC System in Building 1937 Federal contract opportunity
- Solicitation number
- W91151-17-B-0006
About this file
Revised Drawing C-103
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Abstract_of_Bids-17-B-0006_(IFB).pdf | ||
| Asbestos_Survey.doc | DOC document | |
| Approved_Amendment_2.pdf | ||
| Approved_Amendment_1.pdf | ||
| Site_Visit_Sign_in_Sheet.pdf | ||
| Approved_Solicitation.pdf | ||
| Attachment_1-_Specifications_Appendix_A_04-Aug-2016.pdf | ||
| TECH_EXHIBIT_A_-_Specifications.pdf | ||
| TECH_EXHIBIT_B_-_Drawings.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOTES:
1EA -3 POLE - 175 AMP (FOR NEW CHILLER)7.
1EA - 1 POLE - 20 AMP (FOR WATT-NODE METER)6.
1EA - 3 POLE - 125 AMP5.
1EA - 2 POLE - 70 AMP4.
1EA - 2 POLE - 100 AMP3.
1EA - 3 POLE - 100 AMP2.
1EA - 3 POLE - 15 AMP1.
PANEL TO SUPPLY NEW AND EXISTING CIRCUITS.
NOTE: BREAKERS THAT WILL NEED TO BE INSTALLED IN NEW
LABEL". LABEL CAN WHERE METER IS TO BE INSTALLED "WATT-NODE METER".
LABEL EXISTING HVAC DISCONNECT SWITCH WITH "ARC FLASH WARNING 9.
AFTER HVAC INSTALLATION HAS BEEN COMPLETED.
LINES AT BUILDING TO ALLOW FOR NEW HVAC INSTALLATION AND REINSTALL
CONTRACTOR SHALL TEMPORARILY DISCONNECT AND DROP COPPER PHONE 8.
OF CONDUIT. RECONNECT NEW WIRING.
3 EA #6 CU CONDUCTORS AND INSTALL WEATHERHEAD AT EACH END
TO THE EAST. INSTALL A 1" EMT CONDUIT UNDER EAVE OF BUILDING W/
RELOCATE #4 TRIPLEX SERVICE SUPPLYING OUT BUILDING TO APP. 20’7.
NECESSARY, CONDUCTOR SIZE SHALL MATCH EXISTING.
WIREWAY OR JUNCTION BOX AND SPLICE CONDUCTORS. IF SPLICING IS
PANEL IS NOT LONG ENOUGH TO TERMINATE, CONTRACTOR SHALL INSTALL
NOTE: IF THE REMAINING EXISTING WIRE FOR CIRCUITS TO BE REINSTALLED IN NEW
#2/0 CU THWN WIRE FROM LOAD SIDE OF DISCONNECT TO NEW UNIT.
CONDUIT TO NEW TERMINATION POINT ON NEW HVAC UNIT. INSTALL 3-PHASE
WIRING TO HVAC UNIT. USE EXISTING CONDUIT AS FEASIBLE AND EXTEND
DISCONNECT SWITCH ON EXTERIOR WALL OF BUILDING. DEMO LOAD SIDE
THE HVAC AND INSTALL 3-PHASE #2/0 CU FROM BREAKER TO EXISTING
SHALL BE A 175A 3-PHASE BREAKER. DEMO WIRE CURRENTLY SUPPLYING
NEW PANEL AND RETERMINATE WIRE. EXCEPTION: NEW HVAC BREAKER
DISCONNECTING. INSTALL SAME PHASE AND SIZE OF BREAKERS IN
NOTE PHASING AND AMPERAGE OF EXISTING BREAKERS PRIOR TO
REINSTALL ALL EXISTING CONDUITS TO NEW PANEL. CONTRACTOR SHALL6.
FROM PANEL TO WATT-NODE METER.
CABINET. INSTALL A 1/2" CONDUIT WITH A 120V CIRCUIT ON A 20A BREAKER
CT’S FOR WATT-NODE SHALL BE INSTALLED ON LINE SIDE WIRING INSIDE
INSTALL WATT-NODE METER INSIDE CABINET WHERE OLD METER WAS. 7.
TYPE CONNECTORS.
HEAD (INSTALL NEW WEATHERHEAD) TERMINATE CONDUCTORS USING CRIMP
EXISTING CONDUIT FROM PANEL THROUGH CABINET AND OUT OF WEATHER-
MAIN BREAKER AND INSTALL 4EA - #350KCMIL THWN CU CONDUCTORS IN
INSTALL 400A 3-PHASE 120/208V PANEL (MINIMUM 24 CIRCUITS WITH 350A 6.
CT’S, METER INSIDED CABINET AND PANEL.
DEMO EXISTING WIRE FROM WEATHERHEAD BACK TO PANEL TO INCLUDE5.
OF 35’ POLE AND TO EXISTING SECONDARY SPOOL AT BUILDING.
INSTALL PARALLEL #2/0 ALUMINUM QUAD FROM TRANSFORMER POLE TO TOP 4.
EXCAVATED DIRT FROM AROUND POLE.
BUILDING AS SHOWN. REPLACE CONCRETE TO POLE AND REMOVE
SAW-CUT CONCRETE AND INSTALL 35’ CL2 WOOD POLE NEAR EXISTING 3.
DEMO EXISTING SINGLE CONDUCTOR 3 - PHASE SERVICE TO BUILDING.2.
ROTATION REMAINS THE SAME.
120/240V - 7200/12470Y CONNECTED FOR 120/208V SECONDARY. ENSURE
DEMO EXISTING 25KVA TRANSFORMERS AND REPLACE WITH 3 EA 37.5 KVA1.
NUMBER
REFERENCE
SHEET
Project No.
D e s ig n e d B y
D a te
M a rk
Bldg. No.
F T
H O
O D T
E X
A S
S A
N T
A F
E E
N G
IN
E E
R D
R
B
L D
G
F O
R T H
O O
D T
E X
A S
P U
B L
IC
W
O R
K S
D
IR
E C
T O
R A
T E O
F
A B C D E F
D a te
D e s c ri p ti o n
DPW
FORT HOOD TEXAS
n oi sivi
D secivreS & gn ir ee ni g n
E
D ir ec to rat eofPublic
W o rk s
P R
O J E
C T M
A N
A G
E R
P U
R P
O S
E S O
N L
Y F
O R B
ID
D
IN
G T
E C
H N
IC
A L E
X H
IB
IT
B
/2
/2
:5
:1
A
M G E
N G
S
V C \P ro j\ C
A P -B
H
V A
C \F lo o rp la n s
D e s ig n \C -1
.d g n
A
A B
R A
H A
M
-J
U L -2
CA093390P
R E
P L
A C
E H
V A
C S
Y S
T E
M
T
SERVICE
DEMO EXISTING
WOOD POLE
35’ CL 2
REPLACE TRANSFORMERS
ROOM
MECH
3 - #6 CU CONDUCTORS
1" CONDUIT W/
(SEE NOTE 7)
SERVICE
RELOCATE
QUAD
PARALLEL #2/0
QUAD
PARALLEL #2/0
(REPLACE)
EXISTING PANEL
File details come from the government source that posted it. Updated .