W58RGZ-16-R-0244

26 July 16

Attachment 2 SOW - Appendix A Low Voltage Metering Measurements

Channel Measurement Tolerances for Low Voltage Meter

Channel Description
Scale and Resolution
Accuracy
Generator Voltage (3 Channels)
5-325 VAC@400Hz
+/- 0.5% reading +/- 0.5% range
CT Volts (3 Channels)
0 - 10 VAC
+/- 0.5% reading +/- 0.5% range
Speed Sensor
0 - 10 VAC
+/- 0.5% reading +/- 0.5% range
Field Voltage
+/- 200 VDC
+/- 0.5% reading +/- 0.5% range
Field Current
+/- 10 ADC
+/- 0.5% reading +/- 0.5% range

Appendix B Universal Electrical Adapter

The list of eight different program configurations the new electrical adapter’s capability.

Aircraft Generator Configurations

PROGRAM

WBS LISTING

UNIT UNDER TEST DESCRIPTION
UNIT UNDER TEST PART NUMBER
DMWR

NAVAIR

ADAPTER P/N

B87
UH60 APU GEN
28B262-35B,C
1-6115-502
A26123
THD
CH47 APU GEN
31161-001
55-6115-496
A26127
5G8
UH60 GEN
70550-0231-111 & 28B302-8-DM
1-6115-504

A26129

H30
OH58 10KVA GEN
406-075-803-101
1-6115-508

A23541

E90
UH60 GEN
AGH958-1
1-6115-513
A26125
BXC
CH47 AC GEN
179-60500-11 & AE2152MK2
55-6115-507

A26130

KXH
CH47 GEN
V4015 & AGH942-1
1-6115-511
A26126
4D0
UH1N DC GEN
23046-020
03-5AG-47
A26128

Appendix C

Project Management Milestones Schedule

Project Schedule for Automation Generator Test Stand

MILESTONE
DATE
DELIVERABLE
DESCRIPTION
Contract Awarded
September 30, 2016
Project Preliminary Design Review Kick-Off
January 09, 2017
C.4.4.5, C.5.3.1 Section S. C.5.4.1 Section 1 - 5.
Discuss Concept Design & User Interface Input.
Critical Design Review
February 13, 2017
C.3.3, C.6.2, C.4.4.5
Universal Generator Adapter & Software
Software Design
March 14, 2017
C.5.3.1 Section E C.5.3.2, C.5.3.4 Section 1, C.5.3.5
Universal Generator Control Software (AVR+)
Adapter Production
March 15, 2017
C.5.3.4
Universal Generator Adapter
Shipment
August 15, 2017
C.6.3
Deliver to Bldg 1880
Software Integration
August 29, 2017
C.5.3.2
Debug Software
Acceptance Testing
September 3, 2017
C.6.4. Section 1 C.7.
UUT Test & debug
Manuals
September 3, 2017
C.3.1 Section 6.
Updated Operator & Training Manuals
Drawings
September 3, 2017
C.3.1 Section 7, 8
Updated Equipment Drawing Set with Parts list
Start-up, Training, & Final Acceptance
September 26, 2017
C.3.7., C.3.1 Section 10.
Verify Interface Upgrade is compatible to UUT Configuration & meet requirements.

Appendix D Fault Reporting Sheet

Use this type of format will reporting discrepancies throughout the project.

Appendix E

Change Control Form

Change Control Form

Section A

Project

Change Number

Controlled Item

Item Version

Identification of Aspect to be Change
For Document give section number / page number

For Software give Module, Screen or Report name

Change Details Include indication of importance and urgency

Tick if Continued Overleaf

Requester of Change Print Name

Date Raised

Section B

Investigator of Change

Impact, give details of other items affected

Investigation Outcome Reject / Action at No Cost / Action at Cost Suggested Priority High / Medium / Low Date Investigated

Section C

Implementor

Date Scheduled

Section D

Change Implemented
Signature
Date

Implementator

Project Manager

How to Use this Form Change Requester completes ALL boxes in Section A and passes to Project Manager.

Project Manager arranges investigation of request, depending on outcome request is rejected, or given a priority and cost, and with investigator completes Section B & C, form is then retained in project files. Once change is implemented Section D is signed-off.

Appendix F Equipment Layout Drawing, PDF Format

This is a floor plan layout of the Rotating Electric shop. Engineering has a PDF copy of this floor plan.

Appendix G

Adapters currently owned by CCAD.

A list of currently owned adapters available for re-use.

UUT
UUT PN
DMWR
Avtron

Adapter PN Avtron Software PN

UH60 APU GEN
28B262-35B,C
55-115-502
A26123
686123
CH47 APU GEN
31161-001
55-6115-496
A26127
686119
UH60 GEN
70550-0231-

111 & 28B302- 1-6115-504 &

55-6115-504

A26129
686124
OH58 10KVA GEN
406-075-803-
1-6115-508
A23541
686121
UH60 GEN
AGH958-1
1-6115-513
A26125
686116
CH47 AC GEN
179-60500-11 & AE2152MK2
55-6115-507
A26130
686118
CH47 GEN
V4015 & AGH942-1
1-6115-511
A26126
686120
UH1N DC GEN
23046-020
03-5AG-47
A26128
686122

image2.emf image1.emf

Microsoft_Excel_Worksheet1.xlsx Fault Repor

FAULT REPORT

Project Name => Automation Generator Test Stand Project

Severity Date

Severity Level =>

Resolved Date

Engr/Tech Name =>

Date Problem / Findings Description Severity How Problem was Resolved Engr/Tech Comments

File details come from the government source that posted it. Updated .