Attachment_2_-_SOW_Appendices_A_through_G_-_26_July_16.docx
DOCX document 370 KB Posted
- Attached to
- AUTOMATION GENERATOR TEST STAND
- Solicitation number
- W58RGZ16R0244
About this file
Attachment 2
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Pre_Test_DMWR_1-6115-502.pdf | ||
| Leak_Test_DMWR_1-6115-504.pdf | ||
| W58RGZ-16-R-0244_0003_1.pdf | ||
| Preliminary_Test_DMWR_1-6115-513.pdf | ||
| W58RGZ-16-R-0244_02.pdf | ||
| Attachment_1-_CCAD_Security_Requirements_-_26_Jul_16.docx | DOCX document | |
| SOLICITATION_W58RGZ-16-R-0244_GENERATOR_TEST_STAND.pdf | ||
| Exhibit_B_-_DOCUMENT_SUMMARY_LIST_(test_stand)-_5_Jul_16.xlsx | XLSX spreadsheet | |
| CDRLs_A001-A012.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W58RGZ-16-R-0244
26 July 16
Attachment 2 SOW - Appendix A Low Voltage Metering Measurements
Channel Measurement Tolerances for Low Voltage Meter
| Channel Description |
| Scale and Resolution |
| Accuracy |
| Generator Voltage (3 Channels) |
| 5-325 VAC@400Hz |
| +/- 0.5% reading +/- 0.5% range |
| CT Volts (3 Channels) |
| 0 - 10 VAC |
| +/- 0.5% reading +/- 0.5% range |
| Speed Sensor |
| 0 - 10 VAC |
| +/- 0.5% reading +/- 0.5% range |
| Field Voltage |
| +/- 200 VDC |
| +/- 0.5% reading +/- 0.5% range |
| Field Current |
| +/- 10 ADC |
| +/- 0.5% reading +/- 0.5% range |
Appendix B Universal Electrical Adapter
The list of eight different program configurations the new electrical adapter’s capability.
Aircraft Generator Configurations
PROGRAM
WBS LISTING
| UNIT UNDER TEST DESCRIPTION |
| UNIT UNDER TEST PART NUMBER |
| DMWR |
NAVAIR
ADAPTER P/N
| B87 |
| UH60 APU GEN |
| 28B262-35B,C |
| 1-6115-502 |
| A26123 |
| THD |
| CH47 APU GEN |
| 31161-001 |
| 55-6115-496 |
| A26127 |
| 5G8 |
| UH60 GEN |
| 70550-0231-111 & 28B302-8-DM |
| 1-6115-504 |
A26129
| H30 |
| OH58 10KVA GEN |
| 406-075-803-101 |
| 1-6115-508 |
A23541
| E90 |
| UH60 GEN |
| AGH958-1 |
| 1-6115-513 |
| A26125 |
| BXC |
| CH47 AC GEN |
| 179-60500-11 & AE2152MK2 |
| 55-6115-507 |
A26130
| KXH |
| CH47 GEN |
| V4015 & AGH942-1 |
| 1-6115-511 |
| A26126 |
| 4D0 |
| UH1N DC GEN |
| 23046-020 |
| 03-5AG-47 |
| A26128 |
Appendix C
Project Management Milestones Schedule
Project Schedule for Automation Generator Test Stand
| MILESTONE |
| DATE |
| DELIVERABLE |
| DESCRIPTION |
| Contract Awarded |
| September 30, 2016 |
| Project Preliminary Design Review Kick-Off |
| January 09, 2017 |
| C.4.4.5, C.5.3.1 Section S. C.5.4.1 Section 1 - 5. |
| Discuss Concept Design & User Interface Input. |
| Critical Design Review |
| February 13, 2017 |
| C.3.3, C.6.2, C.4.4.5 |
| Universal Generator Adapter & Software |
| Software Design |
| March 14, 2017 |
| C.5.3.1 Section E C.5.3.2, C.5.3.4 Section 1, C.5.3.5 |
| Universal Generator Control Software (AVR+) |
| Adapter Production |
| March 15, 2017 |
| C.5.3.4 |
| Universal Generator Adapter |
| Shipment |
| August 15, 2017 |
| C.6.3 |
| Deliver to Bldg 1880 |
| Software Integration |
| August 29, 2017 |
| C.5.3.2 |
| Debug Software |
| Acceptance Testing |
| September 3, 2017 |
| C.6.4. Section 1 C.7. |
| UUT Test & debug |
| Manuals |
| September 3, 2017 |
| C.3.1 Section 6. |
| Updated Operator & Training Manuals |
| Drawings |
| September 3, 2017 |
| C.3.1 Section 7, 8 |
| Updated Equipment Drawing Set with Parts list |
| Start-up, Training, & Final Acceptance |
| September 26, 2017 |
| C.3.7., C.3.1 Section 10. |
| Verify Interface Upgrade is compatible to UUT Configuration & meet requirements. |
Appendix D Fault Reporting Sheet
Use this type of format will reporting discrepancies throughout the project.
Appendix E
Change Control Form
Change Control Form
Section A
Project
Change Number
Controlled Item
Item Version
| Identification of Aspect to be Change |
| For Document give section number / page number |
For Software give Module, Screen or Report name
Change Details Include indication of importance and urgency
Tick if Continued Overleaf
Requester of Change Print Name
Date Raised
Section B
Investigator of Change
Impact, give details of other items affected
Investigation Outcome Reject / Action at No Cost / Action at Cost Suggested Priority High / Medium / Low Date Investigated
Section C
Implementor
Date Scheduled
Section D
| Change Implemented |
| Signature |
| Date |
Implementator
Project Manager
How to Use this Form Change Requester completes ALL boxes in Section A and passes to Project Manager.
Project Manager arranges investigation of request, depending on outcome request is rejected, or given a priority and cost, and with investigator completes Section B & C, form is then retained in project files. Once change is implemented Section D is signed-off.
Appendix F Equipment Layout Drawing, PDF Format
This is a floor plan layout of the Rotating Electric shop. Engineering has a PDF copy of this floor plan.
Appendix G
Adapters currently owned by CCAD.
A list of currently owned adapters available for re-use.
| UUT |
| UUT PN |
| DMWR |
| Avtron |
Adapter PN Avtron Software PN
| UH60 APU GEN |
| 28B262-35B,C |
| 55-115-502 |
| A26123 |
| 686123 |
| CH47 APU GEN |
| 31161-001 |
| 55-6115-496 |
| A26127 |
| 686119 |
| UH60 GEN |
| 70550-0231- |
111 & 28B302- 1-6115-504 &
55-6115-504
| A26129 |
| 686124 |
| OH58 10KVA GEN |
| 406-075-803- |
| 1-6115-508 |
| A23541 |
| 686121 |
| UH60 GEN |
| AGH958-1 |
| 1-6115-513 |
| A26125 |
| 686116 |
| CH47 AC GEN |
| 179-60500-11 & AE2152MK2 |
| 55-6115-507 |
| A26130 |
| 686118 |
| CH47 GEN |
| V4015 & AGH942-1 |
| 1-6115-511 |
| A26126 |
| 686120 |
| UH1N DC GEN |
| 23046-020 |
| 03-5AG-47 |
| A26128 |
| 686122 |
image2.emf image1.emf
Microsoft_Excel_Worksheet1.xlsx Fault Repor
FAULT REPORT
Project Name => Automation Generator Test Stand Project
Severity Date
Severity Level =>
Resolved Date
Engr/Tech Name =>
Date Problem / Findings Description Severity How Problem was Resolved Engr/Tech Comments
File details come from the government source that posted it. Updated .