Q1. Part number 08-06063-001 appears twice under each phase. The description for the first entry is “Antenna Tuner PCB” and the description for the second entry is “Codan Manpack Filter 2110”. Based on the description, we believe the correct part number for the second entry (Codan Manpack filter 2110) should be 08-06064-001. Please confirm. If so, part number 08-06064-001 is also in the parts list. Please advise if the second entry for the 08-06063-001 item should be removed, should be added to the quantity for the 08-06064-001 line item, or other.
A1. Part number 08-06063-001 refers *only* to the Antenna Tuner PCB. The reference to Codan Manpack Filter 2110 is in error and should be disregarded in both the Phase 1 (45 day) and Phase 2 (120 day) delivery lists.
Q2. Both Phase 1 and Phase 2 are listed as 45-day lead-time. Is Phase 2 supposed to be a longer lead-time?
A2. The Phase 2 delivery date is 120 day A.D.C.
Q3. Part number PBC9009-6 (Motorola GP360 Six Bay Battery Charger) has gone end of life. Recommend following Motorola guidance and replace this item with part number WPLN4189AA (220 volt US plug 6 pack battery charger)
A3. The Government CONCURS with this recommendation: Part number PBC9009-6 is DELETED, and REPLACED with part number WPLN4189AA, “220 volt US plug 6 pack battery charger.”
Q4. Part number 08-06185-001 (Codan SSB 2110 Man Pack, Battery Pack, 12V 13Ah NiMH). This part number is for an 8 Amp-hour battery, but the description is for a 13 Amp-hour battery. Please advise which is to be provided.
A4. Should read” 08-06185-001 Battery Pack 12 V 8Ah NiMH Lightweight, robust and waterproof battery pack. Provides for up to 30 hours of continuous operation (Rx/Tx 9:1)”.