W50S9F-20-R-0008 RFI 4.pdf

PDF 90 KB Posted

Attached to
115 Fighter Wing Main Gate Barrier Upgrade Federal contract opportunity
Solicitation number
W50S9F-20-R-0008
Issued by
Department of the Army National Guard

About this file

This document provides details on a federal solicitation for construction services. The 115th Fighter Wing Air National Guard Base in Madison, Wisconsin is seeking a firm fixed-price contract to upgrade main gate barriers at Truax Field, including demolishing and replacing concrete, asphalt, electrical work, and installing two powered drop beam barriers. There are also five options that could be awarded: installing one powered vertical barrier, and one non-powered barrier each at four other bases. The project value is between $500,000 and $1 million, with a 180-day completion schedule. The NAICS code is 236220. This is a total small business set-aside with less than $36.5 million average annual revenue in the past three years. The solicitation closes on August 31, 2020 with a pre-proposal conference on August 18, 2020. Interested parties must register in SAM and check the website for amendments.

View the file

Other files for this federal contract opportunity

Other files attached to 115 Fighter Wing Main Gate Barrier Upgrade, newest first.
File Type Posted
W50S9F-20-R-0008 RFI 3.pdf PDF
W50S9F-20-R-0008 RFI 1.pdf PDF
W50S9F-20-R-0008 RFI 2.pdf PDF
XGFG192006_Addendum-1.pdf PDF
B.07.Site Visit Attendance Sheet.pdf PDF
A.02.SOW XGFG192006 Upgrade Main Gate Barriers no names_specs.pdf PDF
A.03.192006 Upgrade Barriers_Drawing set FINAL.pdf PDF
B.08.W50S9F-20-R-0008 Solicitation.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation W50S9F-20-R-0008 Request For Information #4

Question #1:

What kind of MM fiber? 62.5 or 50 micron?

Question #1 Response:

50 micron

Question #2:

Are we terminating fiber and copper? If so, what kind of ends for fiber? ST, SC or LC? What kind of jacks for Cat5e?

Question #2 Response:

This is dependent upon the manufacturer providing the system. Submit point-to-point wiring diagram of complete interconnected system components including database listing of wire numbers, to and from designations, and wire characteristics.

If you are using a typical back box and jack plate, we typically use a quad plate configuration with both fiber and copper. This includes two Cat5E and Two Cat6 jacks. The Cat6 jacks are colored orange. This is a standard configuration for us with regard to data and phone but all our phones are voice-over-data.

The fiber connectors - SC.

Question #3:

At gates B-1 and B-2, are they to be grounded with rods and #6 bare with hand holes the same as shown for non-powered gates C5#2?

Question #3 Response:

Yes.