B24 Security Upgrade RFI Attachments FINAL.pdf
PDF 2 MB Posted
- Attached to
- Building 24 Security Upgrades
- Solicitation number
- W50S7Z-22-R-0008
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation Amend_R0008.pdf | ||
| 4. SOW - B24 Security Upgrade_05052022 Update.docx | DOCX document | |
| Site Visit Sign In.pdf | ||
| B24 Security Upgrade RFI - Answered_FINAL.docx | DOCX document | |
| Solicitation_B24 Upgrades.pdf | ||
| Solicitation_B24 Upgrades.pdf | ||
| 4. SOW - B24 Security Upgrade.docx | DOCX document | |
| Attachment - B24 Security Upgrade Floor Plan.pdf | ||
| B24 Floor Plan - Security Upgrade.pptx | PPTX presentation |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOUISIANA AIR NATIONAL GUARD
BUILDING 24 HEADQUARTERS
REQUEST FOR INFORMATION
ATTACHMENT 1
CIPHER LOCK
2.4.2 Bullet Resistant Office Door
Contractor shall install cipher lock of Simplex L1021B, equivalent or better. Cipher lock shall be Best compatible inter-changeable key core.
ATTACHMENT 2
METAL DOORS REPLACEMENT
Modification to Original Scope
2.4.4 Exit Only Exterior Doors
2.4.5 Mechanical Double Doors
The modifications are as follows:
Single and Double Metal Doors – Paint and Hardware Install
The following exterior metal doors shall be repainted: Rooms 121, 138, 152, 165, and one metal double doors near Room 121. No room number available to double doors. Reference
B24 Floor Plan above.
The exterior metal doors shall be temporarily removed and repainted. Metal doors and frames shall be properly prepared to receive paint by removing all existing hardware, any existing rust, loose mill scales, and other substrates that could impair bond of paint. Protect all surfaces and surroundings not to received paint. Clean doors using methods recommended in writing by paint manufacturer. Apply paints according to manufacturer’s written instructions and recommendations. After completing painting operations, use workers skilled in the trades involved to reinstall items that were removed. Ensure doors are plumb and true and properly reinstalled and erect in a rigid manner.
In addition, all door shall receive new weather-stripping, door sweep, closers, door stops, and install kick plates (interior side).
Single and Double Metal Doors – Exit Only Doors The following exterior metal doors shall be exit only doors: 121, 138, 152, and one metal double doors near Room 121. No room number available to double doors. Reference B24 Floor Plan.
The Contractor shall also install a commercial door push bar exit device with alarm to the interior side.
Commercial Door Push Bar Exit Device
All exit only doors shall have a Commercial Door Push Bar Exit Device with alarm. New push bar shall be installed to the interior side of door. Alarm will sound when armed when the push bar is depressed. Push bar shall have a keyed cylinder and shall be Best compatible. Push bar shall be ANSI
Grade I approved, exceeds 500,000 cycles; complies with ANSI 117.1 for accessible and usable
Buildings and Facilities Standards; and ADA compliant. Push bar shall have a sign indicating
“Emergency Exit, Push to Open – Alarm will Sound.” Contractor shall install Dynasty Hardware push bar, equivalent or better. See attached push bar product data sheet. Install and place an “Exit Only” sign to the upper portion of the exterior side of the doors. See attachment.
LA ANG does not have records nor drawings on file indicating its specifications including gage, finishes, hardware, pane, and other components.
All new material shall be installed in accordance with manufacturer’s instructions and recommendations.
Contractor shall maintain area secured throughout project. The area shall be cleaned upon completion.
Any additional damage to the work site surrounding shall be repaired at the Contractor’s expense.
Metal Single and Double Doors
Single Metal Door
4 total
Exit Only Sign
Place “Exit Only” sign on the upper area of exterior side of door for all exit only doors
ATTACHMENT 3
CARPET TILE & BASE COVE
PRODUCT DATA
ATTACHMENT 4
ROOM 129 FLOOR PLAN
ADDITION TO SCOPE
2.4.1.1 Room 129: Office Door
Room 129 - Office
Room 129 is currently occupied by the Fighter Wing Command Chief. The office consists of furniture, computer, and personal belongings. This room is approximately 11’-3” x 15’.
Its flooring has 24” x 24” carpet tiles and 4” vinyl wall base.
11’-3”
’-0
Scope
Flooring Replacement
The flooring shown above shall be an addition to the original scope. Existing carpet tiles and base cove shall be fully replaced in the office. All new materials shall match existing and be installed as per manufacturer’s instructions and recommendations. The Contractor shall ensure the new carpet shall be installed in the same pattern as shown above. Please also see Attachment 3 – Carpet Tile &
Base Cove Product Data sheet.
All existing furniture, computer, and personal belongings shall be temporarily removed from area prior to commencing work.
Contractor shall clean the area upon completion. Any additional damage to the work site surrounding shall be repaired at the Contractor’s expense.
Rm 129 Existing Office Flooring – Carpet and Base Cove
ATTACHMENT 5
BULLET RESISTANT
WINDOWS AND DOORS
Bullet-Resistant Metal Windows
The Contractor shall remove existing window units and install new window units located in Rooms
133 and 134. The dimensions shown above are the approximate dimensions from each location.
New fixed windows shall be insulated and double pane. Windows are to match existing windows in style, functionality, dimensions, and appearance. No windows will be removed unless the new windows can be installed the same day.
The Contractor shall fabricate window assemblies from bullet-resistant glazing materials. The glazing material shall have a UL 752 rating of Level 5 as certified by an independent testing laboratory. The glazing shall be “glass clad poly carbonate” (GCP). Its Performance Level shall meet an One Hour Fire Rating Per ASTM E119-98, Class IV Forced Entry Protection Rating per
ASTM F1233-98, and a Sound Insulation Rating Per ASTM E413-87. Glazing material shall also conform to applicable requirements contained in ASTM C1036, ASTM C1048, and ASTM E1300.
Test glazing materials in accordance with the applicable sections of the following testing procedures: ASTM D905, ASTM D1003, ASTM F428, ASTM F548, ASTM D4093, and ASTM
F520.
The Contractor shall inspect the window rough opening and remove any materials, nails, or objects that could interfere with the proper installation. Framing shall be units of sizes and shapes indicated above with minimum frame face dimensions of 2 inches. Window frame color shall be determined through Submittal process. Windows are to be fixed and must be watertight with integral reinforcement. Glass shall be double paned and insulated. All windows shall reduce sunlight.
Ensure wall openings shall meet the requirements of the windows height and width. All windows shall be securely fastened and airtight to wall opening.
Upon completion, remove any labels and thoroughly clean glass surfaces. Remove any protective covering and clean metal surfaces of stains, marks, or other defects per manufacturer’s instructions.
Existing Windows
Bullet-Resistant Storefront Door
The Contractor shall remove existing storefront and install new bullet-resistant Level 5 glass storefront door. Storefront door shall match existing in style, functionality, dimensions, and appearance. Installation shall be in conformance with referenced standards and manufacturer’s written directions and recommendations. The Contractor shall inspect the door rough opening and remove any materials, nails, or objects that could interfere with the proper installation.
Ensure installation shall be leveled, plumbed, straight and aligned with adjacent surfaces with tight joints. Storefront shall also be free of dents, buckles, twists or other imperfections. New threshold shall be set in sealant and secure.
The Contractor shall fabricate storefront door assembly from bullet-resistant glazing materials. New glazing shall single pane. The glazing material shall have a UL 752 rating of Level 5 as certified by an independent testing laboratory. Its Performance Level shall meet an One Hour Fire Rating Per
ASTM E119-98, Class IV Forced Entry Protection Rating per ASTM F1233-98, and a Sound
Insulation Rating Per ASTM E413-87. Glazing material shall also conform to applicable requirements contained in ASTM C1036, ASTM C1048, and ASTM E1300. Test glazing materials in accordance with the applicable sections of the following testing procedures: ASTM D905, ASTM
D1003, ASTM F428, ASTM F548, ASTM D4093, and ASTM F520.
Storefront door shall have a magnetic lock system. Please see Attachment 1 – Cipher Lock.
Upon completion, remove any labels and thoroughly clean glass surfaces. Remove any protective covering and clean metal surfaces of stains, marks, or other defects per manufacturer’s instructions.