Serial #
Installation Date
2 YEAR WARRANTYTHIS PRODUCT IS TO BE INSTALLED AND SERVICED
BY A TRAINED DOOR SYSTEMS TECHNICIAN ONLY.
Operators are shipped in C2 operating mode.
Visit www.liftmaster.com to locate a professional installing dealer in your area.
CONTACT INFORMATION
Logic 5.0 Commercial Door Operator
USER’S GUIDE
Models T, APT, H, J, HJ, GH, and GT
LiftMaster 300 Windsor Drive Oak Brook, IL 60523
LiftMaster.com
FlorS Oval
FlorS Typewritten Text
FlorS Typewritten Text R&S Erection Tri-County Inc.
5265 Jerusalem Ct.
Modesto, CA 95356 Phone (559) 341-9670 Fax (209) 526-9114
Contact: Jason Diers Cell: (209) 652-8047
INTRODUCTION
CYCLE RATINGS
STANDARD DUTY: Models T, APT, J, DJ, Up to 25 cycles/hr. at peak periods. H, DHJ, & SD Up to 80-90 cycles/day.
HEAVY DUTY: Models GT, GH, & GSD 25 cycles/hr. constant high loading in excess of 90 cycles/day.
Congratulations on purchasing a quality LiftMaster Logic 5.0 Commercial Door Operator.
The Logic 5.0 operator provides everything you know and trust in the prior version, plus the new features listed below:
MyQ® Technology
• Enables secure monitoring and control of the operator with a smartphone, tablet or computer (requires a LiftMaster
Internet Gateway) Security+ 2.0®
• Increased security – with every click a new code is sent to the commercial door operator ensuring the door opens only for the individual pressing the remote
• Enhanced radio communicates with tri-band frequency to improve range and reduce interference – assuring the door opens, stops and closes conveniently and reliably every time Dual Voltages
• Single phase operators provide (115V and 230V)
• 3 phase operators provide (208/230V and 460V)
• 575V operator
INTRODUCTION TO PROGRAMMING
PROGRAMMING
Before programming the logic board, set the operator’s open and close limits. LEDs on the logic board are provided to assist setting the limits. As each limit is activated the corresponding LED will light up. The abbreviations are Open Limit Switch (OLS), Close Limit Switch (CLS) and Sensing Limit Switch (SLS).
When power is applied to the operator, the following LED’s will illuminate: STOP, CLOSE, OPEN, LMEP, 24Vac, RADIO, DATA, TIMER ENABLE, OLS MID, SLS, CLS, and MAS. Once the power up process is completed (approximately 2-3 seconds) only the appropriate LED’s will continue to be lit (i.e., STOP, 24Vdc, limit LED(s) if limit(s) is activated).
NOTE: When the power up process is over, the MAS LED will blink a code indicating the version of firmware. If the selector dial is in the DIAG, OPTN, or PROG position, the MAS will not provide this code. After the code has been provided the MAS LED will go out.
Many programmable functions require that a LiftMaster Entrapment Protection (LMEP) Device be installed in order to function.
LOGIC BOARD PUSH BUTTONS (OPEN, CLOSE, STOP)
Open, Close and Stop buttons are mounted directly on the logic board. Thus, making it easy to program as well as having the door control at the electrical box.
Either the stop control or a jumper MUST be wired between terminals 4 and 5 for the push buttons to function.
LOGIC BOARD OVERVIEW
Detección de corriente (trifásica únicamente)
Bloque de terminales de cableado de control
Receptáculos opcionales de tarjetas auxiliares
Conector de antena coaxial
Conector de distribución del sistema (J3)
Puente de dirección del motor
Current Sense (3 Phase ONLY)
Selector Dial (used for programming and selecting wiring type)
Main Motor Control Harness Connection
Maximum Run Timer Button
Optional Auxiliary Card Receptacles
Mid-Stop Learn Button
Timer-To-Close Learn Button
Radio Learn Button
Open Button
Close Button
Stop Button
Control Wiring Terminal Block
System Wiring Connector (J3)
Coaxial Antenna Connector
Motor Direction Jumper
Maintenance Alert System Button for Programming
Single Phase & Three Phase Jumper
DETERMINE AND SET WIRING TYPE
Read the descriptions of the different wiring types to determine which setting will be correct for each application. Once the wiring type is determined, set the selector dial accordingly.
SELECTOR DIAL
IMPORTANT NOTES:
1. External interlocks may be used with all functional modes.
2. Auxiliary devices are any devices that have only dry contacts.
Examples: loop detector, pneumatic or electrical treadles, radio controls, one button stations, pull cords, etc.
3. Open override means that the door may be reversed while closing by activating an opening device without the need to use the stop button first.
4. When the door is in a stopped position other than fully closed, and an LMEP or EDGE input is activated, the Restricted Close (RC) feature will allow a close command when the close button is pressed and held. The operator will begin closing after 5 seconds. If the close button is released the door will stop.
When in E2 mode, the door will move to the fully open position.
LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP)
DEVICE IS REQUIRED
A LiftMaster Entrapment Protection (LMEP) Device is required for the following wiring types.
LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP)
DEVICE IS RECOMMENDED
A LiftMaster Entrapment Protection (LMEP) Device is recommended for the following wiring types.
B2 Momentary contact to open, close and stop, plus wiring for sensing device to reverse and auxiliary devices to open and close with open override. Programmable mid stop available with this wiring type. Compatible with 3-Button Station, 1-Button Station, 1 and 3-Button Remote Control.
TS (TIMER SECURE)
This mode will attempt to close the door from any position except when fully closed, or when a safety input is present.
The stop button will not disable the Timer-To-Close at any position. To disable the Timer-To-Close in this mode, installation of a defeat switch is required (see wiring diagram on the inside cover of operator).
Momentary contact to open, close, and stop with open override and Timer-To-Close. Every device that causes door to open, including a reversing device, activates the Timer-To-Close. Auxiliary controls can be connected to open input to activate the Timer-To-Close. If the timer has been activated, the open button and radio control can recycle the timer. The Timer-To-Close will function from the programmable mid stop with this wiring type. Compatible with 3-Button Station, 1-Button Station and 1 and 3-Button Remote Control.
NOTE: A Programmable “Car Dealer Mode” available.
T Momentary contact to open, close, and stop, with open override and Timer-To-Close. Every device that causes the door to open, except any sensing edge input device, activates the Timer-To-Close. Auxiliary controls can be connected to open input to activate the Timer-To-Close.
If the Timer-To-Close has been activated, the open button and radio control can recycle the timer. The stop button will deactivate the timer until the next command input. The Timer-To-Close will function from the programmable mid stop with this wiring type. Compatible with 3-Button Station,1-Button Station and 1 and 3-Button Remote Control.
NOTE: Programmable “Car Dealer Mode” available.
FSTS Momentary button contact for open, close and stop programming. User set mid stop. User set Timer-To-Close.
The single button station opens the door to the full open limit bypassing the mid stop and activates the Timer-To-Close, putting the operator in TS mode until the door reaches the down limit, or is stopped in travel. At which time the operator enters the B2 mode.
Compatible with 3-Button Station, 1-Button Station, 1 and 3-Button Remote Control. A 1-Button remote control in FSTS mode will open only with the Timer-To-Close, bypassing a programmed mid stop. The Timer-To-Close will reset and reverse when closing.
C2 Momentary contact to open and stop with constant pressure to close, open override plus wiring for sensing device to reverse. Programmable mid stop available with this wiring type. Compatible with 3-Button Station and 1-Button Station.
E2 Momentary contact to open with override and constant pressure to close. Release of close button will cause door to reverse (roll-back feature) plus wiring for sensing device to reverse. Compatible with 3-Button Station.
D1 Constant pressure to open and close with wiring for sensing device to stop. Compatible with 2 or 3-Button Station.
PROGRAMMING
RADIO
SLS
MRT MID TTC TIM
ENA
1 2 3
CLS
O T
O R
E C
T
IO
N
TTC
LMEP:
EDGE:
OPEN
CLOSE
STOP
COMMON
TIMER
ENABLE
FSTS
DIAG
OPTN
PROG
RADIO
SLS
MRT MID TTC TIM
ENA
1 2 3
FSTS
T TS
E2
CLS
MID
M O
T O
R D
IR
E
C T
IO
N
A S
E
REMOTE CONTROLS
To prevent possible SEVERE INJURY or DEATH:
• Install a LiftMaster Monitored Entrapment Protection (LMEP)
Device.
• NEVER permit children to operate or play with door control push buttons or remote controls.
• Activate door ONLY when it can be seen clearly, is properly adjusted and there are no obstructions to door travel.
• ALWAYS keep door in sight until completely closed. NEVER permit anyone to cross the path of closing door.
SINGLE BUTTON REMOTE CONTROL
3-BUTTON REMOTE CONTROL TO OPERATE AS A WIRELESS 3-BUTTON CONTROL STATION
NOTE: The feature will use 3 of the 90 memory channels in the operator.
TO ERASE ALL REMOTE CONTROLS
1 Press and release the RADIO button (RADIO LED will light). 2
1 2 3Press and release the RADIO button on the logic board (the Radio LED will light).
Press and release the desired button on the logic board (OPEN, CLOSE or STOP). The Radio LED will flash and then stay on solid.
Press and hold the desired button of the remote control until Radio LED flashes rapidly, then release.
Repeat steps 1 through 4 to program additional buttons.
Press and hold the remote control button until the RADIO LED flashes rapidly, then release remote control button. The RADIO LED will then remain on solid after releasing the button. Repeat to add additional remote control(s).
1 Press and hold the RADIO button on the logic board until the RADIO LED flashes rapidly (approximately 5 seconds). All remote controls will be erased.
RADIO
SLS
MRT MID TTC TIMER
ENABLE
1 2 3
FSTS
T TS
E2
CLS
MID
M O
T O
R D
IR
E
C T
IO
N
A S
E
A S
E
3 Press and release the RADIO button to complete the programming. The programming mode is exited if no activity is performed within 30 seconds.
RADIO
SLS
MRT MID TTC T
EN
1 2 3
FSTS
T TS
E2
CLS
MID
VD
M O
T O
R D
IR
E
C T
IO
N
H A
S E
Built in 3-channel, Security+2.0® radio receiver allows you to add up to 90 remote control devices and up to 30 keyless entry devices.
NOTE: The following programming requires a LiftMaster Monitored Entrapment Protection (LMEP) Device.
PROGRAMMING
RADIO
SLS
MRT MID TTC TIM
ENA
1 2 3
T TS
CLS
O T
O R
R E
C T
IO
N
Press and release the RADIO button to complete the programming. The programming mode is exited if no activity is performed within 30 seconds.
NOTICE: To comply with FCC and/or Industry Canada (IC) rules, adjustment or modifications of this transceiver are prohibited. THERE ARE NO USER SERVICEABLE PARTS. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC rules and IC RSS-210. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. This device must be installed in a way where a minimum 8" (20 cm) distance is maintained between users/bystanders and device.
1. To enter programming mode, press and release the RADIO button on the logic board (the RADIO LED will light).
2. To program the MyQ device, place the MyQ device into learn mode (see instructions for the specific MyQ device).
3. When the programming is complete the RADIO LED will turn off.
NOTE: If the programming is not completed within 3 minutes, the program mode will be exited and the RADIO LED will turn off.
MyQ® SETUP (OPTIONAL) For Smartphone App, tablet or PC control, LiftMaster MyQ Internet Gateway (model 828LM) is required.
TO ERASE ALL MYQ DEVICES:
1. Press and release the RADIO button on the logic board (the
RADIO LED will light).
2. Press and hold the MAS button for 5 seconds. The RADIO LED will flash for approximately 5 seconds and the RADIO LED will turn off.
All MyQ devices are now erased.
Please visit LiftMaster.com/MyQ-CDO for troubleshooting information.
Operation will vary depending on wiring type
SELECTOR DIAL
Operation will vary depending on wiring type
SELECTOR DIAL
To prevent possible SEVERE INJURY or DEATH:
• Install a LiftMaster Monitored Entrapment Protection (LMEP)
Device.
• NEVER permit children to operate or play with door control push buttons or remote controls.
• Activate door ONLY when it can be seen clearly, is properly adjusted and there are no obstructions to door travel.
• ALWAYS keep door in sight until completely closed. NEVER permit anyone to cross path of closing door.
TIMER-TO-CLOSE
Feature: Timer automatically closes the door after preset time. All entrapment protection devices must be unobstructed.
Benefit: The door will automatically close after the preset amount of time. Great for apartment buildings, fire stations and other applications where the end user wants the door to close automatically after a specified amount of time.
Requirements: Must have at least one LiftMaster Monitored Entrapment Protection (LMEP) Device installed (refer to installation manual). Wiring type must be set to TS, T or FSTS.
TO PROGRAM MANUALLY (METHOD 1):
1. Close the door.
2. Turn the selector dial to PROG.
3. Press and release the TIMER button on the logic board.
4. Press and release the STOP button to clear the timer.
5. Press and release the OPEN button for every second the operator should wait before attempting to close the door. Press and release the CLOSE button for every 15 seconds the operator should wait before closing the door.
6. Press and release the TIMER button to complete programming.
The OPEN/CLOSE button LEDs will flash to confirm the timer setting. The OPEN LED will flash once for every second programmed and the CLOSE LED will flash once for every 15 seconds programmed.
7. Turn the selector dial to desired timer wiring type (TS ,T or
FSTS).
Example: To close the door after 70 seconds. Turn selector dial to PROG, press and release the TIMER button, press and release the STOP button to clear the timer, press and release the CLOSE button four times for 60 seconds and press and release the OPEN button 10 times for 10 seconds. Press the TIMER button to finish programming the timer. Turn the selector dial to desired timer wiring type (TS, T, or FSTS).
PROGRAM TIMER-TO-CLOSE BY EXAMPLE (METHOD 2):
TO PROGRAM:
1. Close the door.
2. Turn the selector dial to PROG.
3. Press and hold TIMER button for 5 seconds until OPEN and
OLS flashes then release.
4. Press and release the OPEN button and wait for the door to reach full open or mid stop position.
5. Wait for desired amount of time to pass. (An internal stop watch starts counting when the door stops moving.)
6. Press and release the TIMER button, CLOSE button or STOP button to stop the timer. (TIMER SET LED will turn on.)
7. Turn the selector dial to the desired wiring type (T, TS, FSTS).
NOTE: To read back the Timer-To-Close setting, turn the selector dial to DIAG and press the TIMER button. The OPEN LED will flash once for every second programmed and the CLOSE LED will flash once for every 15 seconds programmed.
In T Mode, timer can be deactivated from the open position by pressing the STOP button. The timer will be reactivated on the next operation command. The STOP button WILL NOT deactivate the timer in the TS mode. To deactivate the timer for more than one cycle in T mode or in TS mode, attach a defeat switch to 11 and 12 (COMMON and TIMER DEFEAT).
To prevent possible SERIOUS INJURY or DEATH from a falling door or arm:
• DO NOT stand under the door arm when pulling the emergency release.
• If possible, use emergency release handle to disengage trolley
ONLY when door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
• NEVER use emergency release handle unless doorway is clear of persons and obstructions.
EMERGENCY DISCONNECT SYSTEM MODEL GT AND T
MANUAL RELEASE
TO DISCONNECT DOOR FROM OPERATOR
The door should be in the fully closed position if possible.
Pull emergency release handle straight down. Emergency disconnect will open.
TO RECONNECT DOOR ARM TO TROLLEY
Lift free end of door arm to trolley. Pull emergency release handle to allow arm to engage roll pin. Release handle.
Emergency disconnect will close.
NO
ECIT
EMERGENCY DISCONNECT SYSTEM MODEL APT
TO DISCONNECT DOOR FROM OPERATOR
The door should be in the fully closed position if possible.
Pull down on the emergency release handle and raise or lower the door manually.
TO RECONNECT DOOR ARM TO TROLLEY
The trolley will reconnect on the next UP or DOWN operation, either manually or by using the door control or remote.
NO
ECIT
MANUAL RELEASE
This operator has provisions for manually operating the door in case of emergency or power failure. Refer to the appropriate instructions below for your model operator.
MODEL HJ
This operator includes both a floor level disconnect chain (sash chain) to disconnect the door from the door operator and a disconnect chain with manual hoist to electrically disable the operator controls.
Pull the disconnect chain to engage the hoist mechanism.
The disconnect chain may be locked in position by slipping the end through the keyhole of the chain keeper mounted on the wall.
To disengage, pull the disconnect chain and secure in the disengaged position by slipping the end through the keyhole bracket mounted on the wall.
Operate the door in the desired direction by pulling on one side or the other of the continuous loop hoist chain.
Release the disconnect chain to operate the door again electrically.
To prevent possible SERIOUS INJURY from a moving chain:
• DISCONNECT electric power to the operator BEFORE manually operating your door.
• If possible, use emergency disconnect ONLY when door is
CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
• NEVER use emergency disconnect unless doorway is clear of persons and obstructions.
These operators are equipped with a manual hoist. An electrical interlock will disable the electrical controls when the hoist is used. To operate the hoist:
Pull the disconnect chain (sash chain) to engage the hoist mechanism. The disconnect chain may be locked in position by slipping the end through the keyhole of the chain keeper mounted on the wall.
Operate the door in the desired direction by pulling on one side or the other of the continuous loop hoist chain.
The disconnect chain must be released from the chain keeper before the door will operate again electrically.
MODEL H AND GH
MODEL J
This operator has a floor level disconnect chain to disconnect the door from the door operator.
To disengage, pull the disconnect chain (sash chain) and secure in the disengaged position by slipping the end through the keyhole bracket mounted on the wall.
The door may now be pushed up or pulled down manually.
Release the disconnect chain to operate the door again electrically.
J
EMERGENCY DISCONNECT SYSTEM
MODEL H, GH, J, AND HJ
H and GH
HJ
TESTING
TEST 3-BUTTON CONTROL STATION
1. Press OPEN button. (The door should move in the open direction.)
2. Press STOP button. (The door should stop.)
3. Press and hold the CLOSE button. (The door should move in the close direction.)
4. Release CLOSE button. Door should stop if in C2 or D1 mode.
Door will reverse to full open position in E2 mode. The door should continue closing in all other modes.
5. Press STOP button. (The door should stop.)
TEST LIMIT ADJUSTMENT
1. Press OPEN button. (The door should open.)
2. Allow the door to fully open.
3. Press and hold the CLOSE button. (The door should close.)
4. Allow the door to fully close.
5. If the limits are not set properly, remove power and adjust limits (refer to Limit Adjustment section).
TEST THE PHOTOELECTRIC SENSORS
1. Open the door.
2. Place an obstruction in the path of the photoelectric sensors.
The LMEP LED will blink on the logic board.
3. Press and hold the CLOSE button. The door should not close.
4. Remove the obstruction.
5. Press and hold the CLOSE button. Door should close.
If the LMEP is activated while closing the door should reverse.
IMPORTANT NOTES:
• Be sure you have read and understand all safety instructions included in this manual.
• Be sure the owner or person(s) responsible for operation of the door have read and understand the safety instructions, know how to electrically operate the door in a safe manner and how to manually disconnect the door from the operator.
To avoid SERIOUS personal INJURY or DEATH:
• Disconnect electric power BEFORE performing ANY adjustments or maintenance.
• ALL maintenance MUST be performed by a trained door systems technician.
Apply power to the operator.
When power is applied to the operator, the following LED’s will illuminate: STOP, CLOSE, OPEN, LMEP, 24Vac, RADIO, DATA, TIMER ENABLE, OLS MID, SLS, CLS, and MAS. Once the power up process is completed (approximately 2-3 seconds) only the appropriate LED’s will continue to be lit:
• Between limits: 24Vac and STOP
• Fully closed position: 24Vac, STOP, CLS and SLS
• Fully opened position: 24Vac, STOP and OLS Additional LED’s will light when device(s) are activated.
NOTE: When the power up process is over, the MAS LED will blink a code indicating the version of firmware. If the selector dial is in the DIAG, OPTN, or PROG position, the MAS will not provide this code. After the code has been provided the MAS LED will go out.
CONDITION POSSIBLE CAUSE FIX
OPERATOR WILL NOT
RESPOND TO ANY
COMMANDS
No power Check circuit breaker.
Accessory failure Verify photoelectric sensors are aligned.
Possible component failure Contact your installing dealer.
OPERATOR MAKES
NOISE BUT DOOR
DOES NOT MOVE
Operator requires adjustment Contact your installing dealer.
DOOR DRIFTS AFTER
OPERATOR STOPS
Operator or door requires adjustment Contact your installing dealer.
DOOR OPENS/
CLOSES TOO FAR Operator requires adjustment Contact your installing dealer.
DOOR REVERSES
UNEXPECTEDLY
Entrapment protection device activated
Verify photoelectric sensors are aligned. If photoelectric sensors are aligned and operator still does not operate properly, contact your installing dealer.
RADIO FUNCTIONALITY
NO RESPONSE Remote control is not programmed See PROGRAMMING REMOTE CONTROLS section.
Low battery Replace battery.
REMOTE CANNOT BE
PROGRAMMED Low battery Replace battery.
POOR RANGE Low battery in remote Replace battery.
Possible radio interference Contact your installing dealer.
To locate a dealer in your area visit us online at www.liftmaster.com.
Every 3 months or 5,000 cycles repeat all tests in the Testing section.
Call a trained door systems technician. To locate a dealer in your area visit us online at www.liftmaster.com.
The operator should be serviced at the following intervals:
• Every 3 months or 5,000 cycles
• Every 6 months or 10,000 cycles
• Every 12 months or 20,000 cycles
TROUBLESHOOTING
MAINTENANCE SCHEDULE
To avoid SERIOUS personal INJURY or DEATH:
• Disconnect electric power BEFORE performing ANY adjustments or maintenance.
• ALL maintenance MUST be performed by a trained door systems technician.
CPS-MEI
CPS-EI
Edge Interface 2-Wire Monitored
For use with approved 2-wire edges.
Edge Interface 4-Wire Monitored
For use with approved 4-wire edges.
ENTRAPMENT PROTECTION DEVICES
ACCESSORIES
CPS3CARD Safety Interface Card
Plug-in Interface card enables use of a second set of monitored photo eyes or edge with a commercial door operator.
65-8202
65-5202
Vehicle Detection System:
Pneumatic Sensing Edge Kit with exterior air switch, 2-wire coil cord and 14 foot (4.3 m) air hose.
Vehicle Detection System:
Pneumatic Sensing Edge Kit with exterior air switch, 2-wire take-up reel (20 feet [6 m] extended) and 14 foot (4.3 m) air hose.
NON-MONITORED
MONITORED MONITORED
Dual-Sided Infrared Photo Eyes
• NEMA 1 general purpose enclosure.
• Dual-sided infrared sensors.
• For indoor use.
• Maximum range of 30 feet (9.1 m).
CPS-U
Monitored Thru-Beam Photo Eyes
• Heavy-duty housing for industrial applications.
• NEMA 4 enclosure protects against direct spray.
• Dual-sided infrared sensors.
• For indoor/outdoor use.
• Maximum range of 45 feet (13.7 m).
CPS-UN4
CPS-RPEN4 Monitored Retro-Reflective Photo Eyes
• Polarized reflector for use in applications with highly reflective surfaces.
• NEMA 4X enclosure protects against direct water spray and corrosion.
• Retro-reflective sensor.
• For indoor/outdoor use.
• Maximum range of 50 feet (15 m).
CPS-OPEN4 Monitored Dual-Sided Photo Eyes
• Flexible housings maintain alignment in areas with a high propensity for sensor contact.
• NEMA 4X enclosure protects against direct water spray and corrosion.
• Dual-sided infrared sensors.
• For indoor/outdoor use.
• Maximum range of 45 feet (13.7 m).
OES-SD16 Optical Edge System
16 feet (4.9 m) Sectional 2-Wire Door Edge Kit with infrared optical sensors, rubber door edge and all mounting hardware (channel sold separately).
OES-SD24 Optical Edge System
24 feet (7.3 m) Sectional 2-Wire Door Edge Kit with infrared optical sensors, rubber door edge and all mounting hardware (channel sold separately).
OES-RD16 Optical Edge System
16 feet (4.9 m) Rolling 2-Wire Door Edge Kit with infrared optical sensors, rubber door edge and all mounting hardware (door channel not required).
Optical Edge System (OES)
• Rubber door edge is durable, flexible and easy to install.
• Premium rubber can be cut to length for exact fit.
• NEMA 6 rating protects against moisture and standing water.
• Infrared optical sensors eliminate the need for electrical contacts.
• Maximum range of 33 feet (10 m).
• Sectional and rolling door edges are also available in 50 foot (15 m) bulk rolls, along with individual components for additional savings on large installation jobs.
ACCESSORIES
2-Button Control Station:
Steel enclosure.
1-Button Control Station:
Steel enclosure.
3-Button Control Station:
Steel enclosure with Maintenance Alert System.
02-103L
CONTROL STATIONS
02-102
02-101
Key Control Station:
Indoor fl ush mount, NEMA 1 with Stop button.
1-Button Indoor Surface Mount Station (NEMA 1)
Provides single button to activate opening one or more commercial doors.
02-110
02-401
STAR1000 Commercial Access Control Receiver:
Connects up to 1000 LiftMaster® remote controls.
Supports suspending and unsuspending remote controls to withhold and reinstate access.
RADIO
828LM LiftMaster® Internet Gateway
Enables owners of Commercial Door Operators to open and close their doors and turn on/off lights in or around their facility using a smart phone or tablet computer from anywhere in the world.
Remote Light Control
Automatically control your lights using your commercial door opener, a Security+ 2.0® remote control or a LiftMaster® Internet Gateway. Plugs into any interior outlet.
825LM
Garage and Gate Monitor
Monitor open/closed status for up to 4 MyQ® compatible commercial door openers or gate operators and close them from anywhere in the home.
829LM
MyQ® ACCESSORIES
813LM
811LM
Encrypted DIP Switch Three-Button Remote Control:
Includes Red, Yellow and Green markings which Indicates Open, Close, Stop.
Encrypted DIP Switch Single-Button Remote Control:
Ideal for commercial door applications requiring a large number of remotes for a common space.
REMOTE CONTROLS WITH SECURITY+ 2.0®
& CONNECTIVITY
Wireless Keypad:
Able to be programmed with temporary access codes for visitors or delivery personnel.
877LM
ACCESSORIES
Cast iron bracket to mount J, H, DH, DJ, and GH side mount operators on end bracket of a rolling door or grill. For vertical or horizontal mount on either front or top of coil. Cannot be welded.
Heavy gauge steel bracket for vertical or horizontal mount on either front or top of coil on a rolling door.
Has a variety of mounting hole patterns compatible with many OEM manufacturers. For use with J, H, DJ, and DH operators. May be welded.
08-9098
MOUNTING BRACKETS
10-12360
Same as 08-9098, but with adapter plate to hold mounting bolts in place for easy mounting.
Heavy gauge steel bracket for vertical or horizontal mount on either front or top of coil on a rolling door. May be welded. For use with J, H, DJ, and DH operators.
Same as 1A4324, but with adapter plate to hold mounting bolts in place for easy mounting.
08-9098EZ
1A4324
1A4324EZ
Antenna Extension Kit:
The antenna extension kit can be used with EXT-ANT for maximum radio receiver range.
86LM (15' [4.6 m]) 86LMT (25' [7.6 m])
ADDITIONAL CONTROL ACCESSORIES
For 1" (2.5 cm) shafts. Recommended to properly tension drive chain between operator shaft and door shaft.
71-6023
71-6125 Same as 71-6023, but for 1-1/4" (3.2 cm) shafts.
For Jackshaft Type OperatorsCHAIN TENSIONERS
Red/Green Traffic Light:
Indicates when a commercial door reaches the open position. Provides assurance of safe entering and exiting of the facility, reducing the potential for costly accidents. (TLS1CARD is recommended)
Motion Detector 24V
Microwave motion detector with two independently programmable channels.
Switch Sectional Door Interlock
NEMA 4 switch disables operator control circuit when door is locked preventing electrical operation of the door.
RGL24LY
50-HERK2
50450
OPTION CARDS
Timer Light Status Card:
The TLS option card provides special functionality to activate and fl ash auxiliary devices such as lights, bells, and horns/strobes at various door positions, and to provide special timer functions.
TLS1CARD
Auxiliary Contact Card:
The Auxiliary Contact option card has both Normally- Open and Normally-Closed contacts that actuate when the door is idle, opening, or closing.
AUXCARD
No de série
Date d’installation
GARANTIE DE 2 ANSCE PRODUIT DOIT ÊTRE INSTALLÉ ET ENTRETENU
SEULEMENT PAR UN TECHNICIEN FORMÉ EN
SYSTÈMES DE PORTE.
Les ouvre-portes sont expédiés en mode de fonctionnement C2. Rendez visite à www.liftmaster.com pour localiser le revendeur-installateur le plus proche de chez vous.
COORDONNÉES
Actionneur de porte commerciale Logic 5.0
GUIDE DE L’UTILISATEUR
Modèles T, APT, H, J, HJ, GH, et GT
LiftMaster 300 Windsor Drive Oak Brook, IL 60523
LiftMaster.com
INTRODUCTION
CYCLES NOMINAUX
SERVICE STANDARD: Modéles T, APT, J, DJ, Jusqu’à 25 cycles/h aux périodes de pointe. H, DHJ, et SD Jusqu’à 80 à 90 cycles/jour.
SERVICE SÉVÈRE: Modéles GT, GH, et GSD 25 cycles/h. haute charge continue dépassant 90 cycles/jour.
Félicitations pour votre achat de qualité d’un actionneur de porte commerciale LiftMaster Logic 5.0.
L’actionneur Logic 5.0 vous offre les fonctions utiles et fi ables de la version précédente en plus des nouvelles fonctions présentées ci-dessous :
Technologie MyQ®
• Permet la surveillance sécurisée et la commande de l’actionneur par un téléphone intelligent, une tablette ou un ordinateur (nécessite une passerelle Internet LiftMaster).
Security+ 2.0®
• Sécurité accrue – un nouveau code est envoyé à l’actionneur de porte commerciale à chaque clic de manière à garantir que la porte ne s’ouvre que pour la personne ayant appuyé sur une touche de la télécommande.
• La fonction radio améliorée communique sur trois bandes de fréquences pour une plus grande portée et une interférence réduite, de sorte que la porte s’ouvre, interrompt sa course et se ferme chaque fois de manière commode et fi able.
Double tension
• Les actionneurs monophasés fournissent une tension de 115 V et 230 V
• Les actionneurs triphasés fournissent une tension de 208/230 V et 460 V.
• Actionneur 575 V
Detección de corriente (trifásica únicamente)
Bloque de terminales de cableado de control
Receptáculos opcionales de tarjetas auxiliares
Conector de antena coaxial
Conector de distribución del sistema (J3)
Puente de dirección del motor
INTRODUCTION À LA PROGRAMMATION
Cadran de réglage (utilisé pour la programmation et la sélection du type de câblage)
Connexion du faisceau de commande du moteur principal
Bouton de la minuterie de fonctionnement maximal
Bouton d'apprentissage de mi-course
Bouton d'apprentissage de la minuterie de fermeture
Bouton d'apprentissage radio
Bouton Ouvrir
Bouton Fermer
Bouton Arrêt
Cavalier de direction du moteur
Bouton de programmation du système d'alerte d'entretien
Cavalier une phase et trois phases
PROGRAMMATION
VUE D'ENSEMBLE DE
LA CARTE LOGIQUE
BOUTON-POUSSOIRS DE LA CARTE LOGIQUE (OPEN (OUVRIR),
CLOSE (FERMER), STOP (ARRÊT))
Les boutons OPEN (ouvrir), CLOSE (fermer), STOP (arrêt) sont montés directement sur la carte logique. Ceci facilite la programmation et permet d'avoir la commande de porte à la boîte électrique.
Une commande d’arrêt ou un câble de liaison DOIT être câblé entre les bornes 4 et 5 pour que les boutons-poussoirs puissent fonctionner.
Avant de programmer la carte logique, configurer les fins de course d'ouverture et de fermeture de l'ouvre-porte. Des DEL sont disponibles sur la carte logique pour aider à configurer les fins de course. Chaque fois qu'une fin de course est activée, la DEL correspondante s'allume. Les abréviations sont Interrupteur de fin de course d'ouverture (OLS), Interrupteur de fin de course de fermeture (CLS) et Interrupteur de fin de course de sécurité (SLS).
Lorsque l'alimentation est appliquée à l'ouvre-porte, les DEL suivantes s'allument : STOP (arrêt), CLOSE (fermer), OPEN (ouvrir), LMEP, 24 Vca, RADIO, DATA (données), TIMER ENABLE (permettre minuterie), OLS (inter. fin course ouvert), MID (mi-course), SLS (inter. fin course sécurité), CLS (inter. fin course fermé) et MAS (système d'alerte entretien). Lorsque le processus de démarrage est complété (environ 2 à 3 secondes), seules les DEL appropriées continueront d'être allumées :
(p.ex., STOP (arrêt), 24Vcc, DEL de fin de course si celles-ci sont activées).
REMARQUE : Lorsque le processus de démarrage est terminé, la DEL MAS clignotera un code indiquant la version du micrologiciel. Si le cadran de réglage est en position DIAG, OPTN, ou PROG, le MAS ne fournira pas ce code. Après que le code ait été fourni, la DEL MAS s'éteindra.
Plusieurs fonctions programmables exigent qu'un dispositif de Protection contre le piégeage LiftMaster (LMEP) soit installé pour fonctionner.
Détection de courant (triphasé UNIQUEMENT)
Bornier du câblage de commande
Connecteur de câblage du système (J3)
Connecteur coaxial d’antenne
Réceptacles de cartes auxiliaires en option
DÉTERMINATION ET CONFIGURATION DU TYPE DE CÂBLAGE
Lire les descriptions des différents types de câblage pour déterminer quelle configuration sera correcte pour chaque application.
Lorsque le type de câblage est déterminé, configurer le cadran de réglage en conséquence.
CADRAN DE RÉGLAGE
REMARQUES IMPORTANTES :
1. Des verrouillages externes peuvent être utilisés avec tous les modes fonctionnels.
2. Les dispositifs auxiliaires sont tout dispositifs qui ont seulement des contacts secs. Exemples : capteur de boucle, capteurs pneumatiques ou électriques, commandes radio, stations à un bouton, cordons de tirage, etc.
3. Surpassement d'ouverture signifie que la porte peut être inversée lors de sa fermeture en activant un dispositif d'ouverture sans avoir à utiliser d'abord le bouton d'arrêt.
4. Lorsque la porte est en position d’arrêt sans être toutefois complètement fermée, et qu’un dispositif de protection contre le piégeage ou un capteur d’ARÊTE est activé, le dispositif de Fermeture restreinte (RC) permettra une commande de fermeture lorsque le bouton de fermeture est pressé et tenu. L'ouvre-porte commencera à se fermer après 5 secondes. Si le bouton de fermeture est relâché, la porte s'arrête.
En mode E2, la porte se déplacera jusqu'à la position entièrement ouverte.
UN DISPOSITIF DE PROTECTION CONTRE LE PIÉGEAGE AVEC
SURVEILLANCE LIFTMASTER (LMEP) EST NÉCESSAIRE
Un dispositif de Protection contre le piégeage LiftMaster (LMEP) est nécessaire pour les types de câblage suivants.
UN DISPOSITIF DE PROTECTION CONTRE LE PIÉGEAGE AVEC
SURVEILLANCE LIFTMASTER (LMEP) EST RECOMMANDÉ
Un dispositif de Protection contre le piégeage LiftMaster (LMEP) est recommandé pour les types de câblage suivants.
B2 Contact momentané pour ouvrir, fermer et arrêter, plus câblage au dispositif capteur pour inverser et dispositifs auxiliaires pour ouvrir et fermer avec surpassement d'ouverture. Arrêt mi-course programmable disponible avec ce type de câblage. Compatible avec Station 3 boutons, station 1 bouton et télécommande 3 boutons.
TS (Minuterie sécurisée) Ce mode tentera de fermer la porte à partir de toute position exceptée lorsqu'entièrement fermée, ou lorsqu'une entrée de sécurité est présente. Le bouton d'arrêt ne désactive pas la minuterie de fermeture quelle que soit la position. Pour désactiver la minuterie de fermeture dans ce mode, l'installation d'un interrupteur d'échec est nécessaire (voir le schéma de câblage sur le couvercle intérieur de l’actionneur).
Contact momentané pour ouvrir, fermer et arrêter, avec surpassement d'ouverture et minuterie de fermeture.
Chaque dispositif qui fait en sorte que la porte s'ouvre, incluant un dispositif d'inversement, active la minuterie de fermeture. Les commandes auxiliaires peuvent être connectées à l'entrée d'ouverture pour activer la minuterie de fermeture. Si la minuterie a été activée, le bouton d'ouverture et la commande radio peuvent recycler la minuterie. La minuterie de fermeture fonctionnera à partir de la mi-course programmable avec ce type de câblage.
Compatible avec Station 3 boutons, station 1 bouton et télécommande 1 et 3 boutons.
REMARQUE : Un « mode concessionnaire automobile » programmable disponible.
T Contact momentané pour ouvrir, fermer et arrêter, avec surpassement d'ouverture et minuterie de fermeture.
Chaque dispositif qui fait ouvrir la porte, excepté tout dispositif d'entrée de chant de sécurité, active la minuterie de fermeture. Les commandes auxiliaires peuvent être connectées à l'entrée d'ouverture pour activer la minuterie de fermeture.
Si la minuterie de fermeture a été activée, le bouton ouvrir et la commande radio peuvent recycler la minuterie. Le bouton d'arrêt désactivera la minuterie jusqu'à la prochaine entrée de commande. La minuterie de fermeture fonctionnera à partir de la mi-course programmable avec ce type de câblage. Compatible avec Station 3 boutons, station 1 bouton et télécommande 1 et 3 boutons.
REMARQUE : « Mode concessionnaire automobile » programmable disponible.
FSTS Bouton momentané pour programmation ouvrir, fermer et arrêter. L'utilisateur configure l'arrêt de mi-course.
L'utilisateur configure la minuterie de fermeture. La station à 1 bouton ouvre la porte jusqu'à la fin de course entièrement ouvert surpassant la mi-course et active la minuterie de fermeture, mettant l'ouvre-porte en mode TS jusqu'à ce que la porte atteigne la fin de course du bas ou qu'elle soit arrêtée dans sa course. À ce moment, l'ouvre-porte entre en mode B2.
C2 Contact momentané pour ouvrir et arrêter, avec pression constante pour fermer, surpassement d'ouverture, plus câblage au dispositif capteur pour inverser. Arrêt mi-course programmable disponible avec ce type de câblage.
Compatible avec Station 3 boutons et station 1 bouton.
E2 Contact momentané pour ouvrir surpassement avec surpassement et pression constante pour fermer. Relâcher le bouton de fermeture fera inverser la porte (caractéristique retour en arrière) plus câblage pour dispositif capteur pour inverser. Compatible avec station 3 boutons.
D1 Pression constante pour ouvrir et fermer avec câblage à dispositif capteur pour arrêter. Compatible avec station 2 ou 3 boutons.
PROGRAMMATION
Compatible avec Station 3 boutons, station 1 bouton et télécommande 1 et 3 boutons. Une télécommande 1 bouton en mode FSTS ouvrira seulement avec la minuterie de fermeture, surpassant un arrêt à mi-course programmé.
La minuterie de fermeture se réinitialisera et s'inversera lors de la fermeture.
Pour empêcher une BLESSURE GRAVE ou une MORT possible:
• Installer un dispositif de Protection contre le piégeage avec surveillance LiftMaster (LMEP).
• NE JAMAIS permettre aux enfants de faire fonctionner ou de jouer avec les boutons poussoirs de la commande de porte ou avec les télécommandes.
• Activer la porte SEULEMENT lorsqu'elle peut être vue clairement, qu'elle est correctement ajustée et qu'il n'y a aucune obstruction au déplacement de la porte.
• TOUJOURS garder la porte en vue jusqu'à ce qu'elle soit entièrement fermée. NE JAMAIS permettre à quiconque de croiser la trajectoire d'une porte qui se ferme.
ATTENTION
AVERTISSEMENT
AVERTISSEMENT
AVERTISSEMENT
RADIO
SLS
MRT MID TTC TIM
ENA
1 2 3
FSTS
T TS
E2
CLS
MID
M O
T O
R D
IR
E
C T
IO
N
A S
E
TTC
LMEP:
EDGE:
OPEN
CLOSE
STOP
COMMON
TIMER
ENABLE
FSTS
DIAG
OPTN
PROG
RADIO
SLS
MRT MID TTC TIM
ENA
1 2 3
FSTS
T TS
E2
CLS
MID
M O
T O
R D
IR
E
C T
IO
N
A S
E
TÉLÉCOMMANDES
TÉLÉCOMMANDE À UN BOUTON
TÉLÉCOMMANDE À 3 BOUTONS POUR FONCTIONNER COMME UNE STATION DE CONTRÔLE SANS FIL À 3 BOUTONS REMARQUE : Cette caractéristique utilisera 3 des 90 canaux de mémoire du système de fermeture.
POUR EFFACER TOUTES LES TÉLÉCOMMANDES
1 Appuyer et relâcher le bouton RADIO (la DEL RADIO s’allume). 2
1 2 3 Appuyer et relâcher le bouton RADIO sur la carte logique (la DEL RADIO s’allume).
Enfoncer et relâcher le bouton désiré sur le tableau logique. (OPEN, CLOSE ou STOP). La DEL Radio clignote puis demeure allumée.
Tenir enfoncé le bouton désiré de la télécommande jusqu’à ce que la DEL radio clignote rapidement, puis relâcher le bouton.
Répétez les étapes 1 à 4 pour programmer des boutons supplémentaires.
Appuyer et tenir le bouton de la télécommande jusqu’à ce que la DEL RADIO clignote rapidement, puis relâcher la bouton de la télécommande. La DEL RADIO demeurera allumée lorsque le bouton sera relâché. Répéter pour ajouter des télécommandes additionnelles.
1 Appuyer et tenir le bouton RADIO sur la carte logique jusqu’à ce que la DEL RADIO clignote rapidement (environ 5 secondes).
Toutes les télécommandes seront effacées.
RADIO
SLS
MRT MID TTC TIM
ENA
1 2 3
FSTS
T TS
E2
CLS
MID
M O
T O
R D
IR
E
C T
IO
N
A S
E
3 Appuyer et relâcher le bouton RADIO pour compléter la programmation. Le mode de programmation est quitté si aucune activité n’est effectuée durant 30 secondes.
RADIO
SLS
MRT MID TTC TIM
ENA
1 2 3
FSTS
T TS
E2
CLS
MID
M O
T O
R D
IR
E
C T
IO
N
A S
E
Le récepteur radio à 3 canaux Security✚ 2.0® vous permet de programmer jusqu’à 90 télécommandes et jusqu’à 30 dispositifs d’entrée dans clé.
REMARQUE : La programmation suivante nécessite un dispositif de Protection contre le piégeage avec surveillance LiftMaster (LMEP).
PROGRAMMATION
RADIO
SLS
MRT MID TTC TIM
ENA
1 2 3
FSTS
T TS
E2
CLS
MID
M O
T O
R D
IR
E
C T
IO
N
A S
E
4 Appuyer et relâcher le bouton RADIO pour compléter la programmation. Le mode de programmation est quitté si aucune activité n’est effectuée durant 30 secondes.
AVIS : Pour ce conformer aux règlements de la FCC ou d'Industrie Canada (IC), l'ajustement ou les modifications à ce récepteur et/ou à ce transmetteur sont prohibées. IL N’Y A PAS D’AUTRES PIÈCES POUVANT ÊTRE RÉPARÉES PAR L’UTILISATEUR. Tout changement ou toute modification non expressément approuvé par la partie responsable de la conformité peut avoir pour résultat d’annuler l’autorité de l’utilisateur de faire fonctionner l’équipement. Cet appareil est conforme aux dispositions de la partie 15 du règlement de la FCC et de l’norme IC RSS-210. Le fonctionnement est sujet aux deux conditions suivantes : (1) ce dispositif ne peut pas causer d’interférences nuisibles, et
(2) ce dispositif doit accepter toute interférence reçue, incluant les interférences qui pourrait causer un fonctionnement non désiré. Cet appareil numerique de la classe B est conforme a la norme NMB- 003 du Canada. L’appareil doit être installe d’une façon où un minimum de 8 pouces (20 cm) est maintenu entre l’utilisateur/le passant et l’appareil lui-même.
PROGRAMMATION
1. Pour accéder au mode de programmation, appuyez sur le bouton RADIO de la carte logique (le bouton DEL RADIO clignotera).
2. Pour programmer le dispositif MyQ, placez-le en mode de programmation (consultez les instructions relatives au dispositif MyQ en question).
3. Lorsque la programmation est terminée, le bouton DEL RADIO s’éteindra.
REMARQUE : Si la programmation n’est pas terminée à l’intérieur d’un délai de 3 minutes, le mode de programmation sera désactivé et le bouton DEL RADIO s’éteindra.
CONFIGURATION MYQ® (EN OPTION)
La passerelle Internet LiftMaster MyQ est exigée (modèle 828LM) pour l’application pour téléphone intelligent, commande par tablette ou ordinateur.
POUR SUPPRIMER TOUS LES DISPOSITIFS MYQ :
1. Pressez et relâchez sur le bouton RADIO de la carte logique (le voyant lumineux DEL RADIO clignotera).
2. Pressez et maintenezenfoncé le bouton MAS pendant 5 secondes.
Le bouton DEL RADIO clignotera pendant approximativement 5 secondes, puis s’éteindra.
Tous les dispositifs MyQ sont maintenant supprimés.
Aller à LiftMaster.com/MyQ-CDO pour l’information de dépannage.
Le fonctionnement variera en fonction du type de câblage
CADRAN DE RÉGLAGE
Pour empêcher une BLESSURE GRAVE ou une MORT possible:
• Installer un dispositif de Protection contre le piégeage avec surveillance LiftMaster (LMEP).
• NE JAMAIS permettre aux enfants de faire fonctionner ou de jouer avec les boutons poussoirs de la commande de porte ou avec les télécommandes.
• Activer la porte SEULEMENT lorsqu’elle peut être vue clairement, qu’elle est correctement ajustée et qu’il n’y a aucune obstruction au déplacement de la porte.
• TOUJOURS garder la porte en vue jusqu’à ce qu’elle soit entièrement fermée. NE JAMAIS permettre à quelqu’un de se trouver dans la trajectoire de la porte qui se ferme.
MINUTERIE DE FERMETURE
Caractéristique : La minuterie enclenche automatiquement la fermeture de la porte une fois la durée d’ouverture préprogrammée expirée. Tous les dispositifs de protection contre le piégeage doivent être dégagés.
Avantage : La porte se ferme automatiquement après un temps prédéterminé. Parfait pour les immeubles d’habitation, les postes de pompiers et autres applications où l’utilisateur désire que la porte se ferme automatiquement après une durée spécifiée.
Exigences : Au moins un dispositif de Protection contre le piégeage avec surveillance LiftMaster (LMEP) doit être installé. Le type de câblage doit être configuré à TS, T ou FSTS.
POUR PROGRAMMER MANUELLEMENT (MÉTHODE 1):
1. Fermer la porte.
2. Tourner le cadran de réglage à PROG.
3. Appuyer et relâcher le bouton TIMER (minuterie) sur la carte logique.
4. Appuyer et relâcher le bouton STOP (arrêt) pour vider la minuterie.
5. Appuyer et relâcher le bouton OPEN (ouvrir) pour chaque seconde pendant laquelle l’ouvre-porte devrait attendre avant de tenter de fermer la porte. Appuyer et relâcher le bouton CLOSE (fermer) pour chaque 15 secondes pendant lesquelles l’ouvre-porte devrait attendre avant de fermer la porte.
En mode T, la minuterie peut être désactivée de la position ouverte en appuyant sur le bouton STOP (arrêt). La minuterie sera réactivée lors de la prochaine commande de fonctionnement. Le bouton STOP (arrêt) NE désactivera PAS la minuterie en mode TS.
Pour désactiver la minuterie durant plus d’un cycle en mode T ou en mode TS, fixer un interrupteur d’échec à 11 et 12 (COMMON (commun) et TIMER DEFEAT (échec de minuterie).
6. Appuyer et relâcher le bouton TIMER (minuterie) pour compléter la programmation. Les DEL OPEN (ouvrir)/CLOSE (fermer) clignotent pour confirmer la configuration de la minuterie. La DEL OPEN (ouvrir) clignote une fois pour chaque seconde programmée et la DEL CLOSE (fermer) clignote une fois pour chaque 15 secondes programmées.
7. Ramener le cadran de réglage au type de câblage désiré pour la minuterie (TS, T ou FSTS).
Exemple : Pour fermer la porte après 70 secondes. Tourner le cadran de réglage à PROG, appuyer et relâcher le bouton TIMER (minuterie), appuyer et relâcher le bouton STOP (arrêt) pour vider la minuterie, appuyer et relâcher le bouton CLOSE (fermer) quatre fois pour 60 secondes et appuyer et relâcher le bouton OPEN (ouvrir) 10 fois pour 10 secondes. Appuyer sur le bouton TIMER (minuterie) pour terminer la programmation de la minuterie.
Ramener le cadran de réglage au type de câblage désiré pour la minuterie. (TS, T, FSTS).
PROGRAMMATION DE LA MINUTERIE DE FERMETURE PAR
EXEMPLE (MÉTHODE 2) :
POUR PROGRAMMER :
1. Fermer la porte.
2. Tourner le cadran de réglage à PROG.
3. Appuyer et tenir le bouton TIMER (minuterie) durant 5 secondes jusqu’à ce que OPEN (ouvrir) et OLS clignotent puis relâcher.
4. Appuyer et relâcher le bouton OPEN (ouvrir) puis attendre que la porte atteigne la position entièrement ouverte ou mi-course.
5. Attendre que le temps désiré s’écoule. (Un chronomètre interne commence à compter lorsque la porte cesse de bouger.)
6. Appuyer et relâcher le bouton TIMER (minuterie), le bouton CLOSE (fermer) ou le bouton STOP (arrêt) pour arrêter la minuterie. (la DEL TIMER SET (réglage de minuterie) s’allume.)
7. Ramener le cadran de réglage au type de câblage désiré (T, TS ou FSTS).
REMARQUE : Pour relire le réglage de minuterie de fermeture, ramener le cadran de réglage à DIAG et appuyer sur le bouton TIMER (minuterie). La DEL OPEN (ouvrir) clignote une fois pour chaque seconde programmée et la DEL CLOSE (fermer) clignote une fois pour chaque 15 secondes programmées.
Le fonctionnement variera en fonction du type de câblage
CADRAN DE RÉGLAGE
PROGRAMMATION
Pour empêcher une BLESSURE GRAVE ou une MORT possible à cause d’une porte ou d’un bras qui tombe:
• NE PAS se tenir debout sous le bras de porte lorsqu’on tire le dégagement d’urgence.
• Si possible, utiliser la poignée de dégagement d’urgence pour désengager le chariot SEULEMENT lorsque la porte est FERMÉE. Des ressorts fiables ou brisés ou une porte non balancée pourraient faire en sorte qu’une porte ouverte tombe rapidement ou subitement.
• NE JAMAIS utiliser la poignée de dégagement manuelle à moins que l’embrasure de la porte soit libre de toute personne ou obstruction.
SYSTÈME DE DÉCONNEXION D’URGENCE MODÈLES GT ET T
DÉGAGEMENT MANUEL
POUR DÉCONNECTER LA PORTE DE L’OUVRE-PORTE
La porte devrait être en position entièrement fermée si possible.
Tirer la poignée de dégagement d’urgence droit vers le bas.
La déconnexion d’urgence s’ouvre.
POUR RECONNECTER LE BRAS DE PORTE AU CHARIOT
Lever le bout libre du bras de porte vers le chariot. Tirer la poignée de dégagement d’urgence pour permettre au bras d’engager la goupille cylindrique. Relâcher la poignée. La déconnexion d’urgence se ferme.
SYSTÈ…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .