REQUIREMENTS SPECIFICATION MATRIX FOR PNEUMATIC PRESSURE CONTROLLER
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W31P4Q-16-R-0156_Amendment_0004.pdf | ||
| QUESTIONS_AND_ANSWERS.pdf | ||
| QUESTIONS_AND_ANSWERS.pdf | ||
| W31P4Q16R0156-0001.pdf | ||
| QUESTIONS_AND_ANSWERS.pdf | ||
| W31P4Q-16-R-0156.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Section | Title | GOVERNMENT'S REQUIREMENTS | PROPOSAL |
| 2.1.1 | Configuration #1 Accuracy | The Combined Uncertainty of the pressure measurement shall maintain a 4 to 1 Test Uncertainty Ratio (TUR) when calibrating absolute and gauge type Accuracy Grade 2A (ASME B40.100-2013) and below gauges, from 5 to 2500 psig. |
Combined Uncertainty shall include reference calibration standard (0.000145 psia + 20 ppm), linearity, hysteresis, repeatability, and 1-year stability.
2.2.2 Configuration #2 Accuracy The Combined Uncertainty of the pressure measurement shall maintain a 4 to 1 Test Uncertainty Ratio (TUR) when calibrating absolute and gauge type Accuracy Grade 1A (ASME B40.100-2013) and below gauges, from 5 to 2500 psig.
Combined Uncertainty shall include reference calibration standard (0.000145 psia + 20 ppm), linearity, hysteresis, repeatability, and 1-year stability.
| 2.3 | Control Stability | 0.003% of transducer range or better. |
| 2.4 | Operational Pressure Range | Shall control pressure from -15 to 2500 psig |
| 2.5 | Units | Shall display pressure in the following units: psig, psia, Pa, kPa, MPa, inH20, inHg, mmHg, bar, and mbar. |
| 2.6 | Operational Modes | PPC shall have a control mode and measurement mode. |
| 2.7 | Warm-Up Time | 30 minutes or less. |
| 2.8.1 | Operating Temp | 60 to 90 ºF |
| 2.8.2 | Storage Temp | 0 ºF to 140 ºF |
| 2.8.3 | Humidity | 20% to 90% RH, non-condensing |
| 2.8.4 | Shipping | Standard commercial shipping conditions. |
| 3.1 | Interoperability | The PPC/Chassis shall be capable of accepting and operating with the transducers in Configuration #1 (Section 2.1) and Configuration #2 (Section 2.2). |
| 3.2 | Functional Range | Shall function as defined in Configuration #1 (Section 2.1) and Configuration #2 (Section 2.2) without removing and replacing modules with measurement transducers during operation. |
| 3.3 | Coefficient Storage | Modules with measurement transducers shall maintain calibration coefficients, independent of any PPC/Chassis. |
| 3.4 | Display | LED, LCD, or Plasma screen with alpha numeric characters. All necessary test information shall be displayed on screen. |
| 3.5 | User Interface | All functions of the PPC shall be accessible through the front panel display and front user interface. |
| 3.6 | Remote Interface | PPC shall have remote interfaces through USB, RS-232C and/or IEEE 488.2, and contractor shall provide programming command set for the PPC. All functions of the PPC shall be accessible through the remote interface. |
| 3.7 | Zero Correction | PPC shall have a zeroing function. |
| 3.8 | Head Correction | PPC shall correct for head pressure. |
| 3.9.1 | Calibration | PPC and modules with measurement transducers shall meet all performance requirements, without recalibration, for a period of at least 1 year. |
| 3.9.2 | Calibration | A means to store COMPASS for Pressure Calibration Software (COMPASS) derived calibration coefficients in the modules with transducers shall be provided. |
| 3.9.3 | Calibration | Modules with measurement transducers shall have the capability to be transported and calibrated independent of the original PPC/Chassis with COMPASS software, dead weight system and connect to a SS-QC4-S-400 Swagelok quick connect stem. |
| 3.9.4 | Calibration | Hardware and software beyond Army Secondary Reference calibration/repair capability, shall be provided to support calibration/repair of modules with measurement transducers independent of the original PPC/Chassis, as mentioned in section 3.9.3. |
| 3.9.5 | Calibration | If PPC/Chassis calibration is required, hardware and software for calibration and adjustments beyond Army Secondary transfer calibration capability (capability information provided on request) shall be provided. |
| 3.9.6 | Calibration | Repair parts shall be available for repair of PPC/Chassis and modules with measurement transducers (see 5.2.4 below). Any repairs deemed manufacture only shall be specified and justified. |
| 4.1 | Dimensions | 17.8125” Width and 20.5” Depth Maximum |
| 4.2 | Weight | PPC shall not exceed 44 pounds (1 Person Lift Limit). |
| 4.3 | Rack Mounting | A standard 19” rack mounting kit shall be an available option. |
| 4.4 | Power | PPC shall operate on 120VAC 60Hz, 15A single phase, standard U.S. electrical power, and come equipped with standard U.S. plug type. |
| 4.5 | Connection Ports | PPC shall have easily accessible ports for pressure and vacuum connections. Connections shall be or adapt to 1/8” NPT. Any necessary adapters shall be provided. Source pressure ports shall clearly be labeled with maximum input pressure. All ports shall be labeled with size and thread type. |
| 4.6 | Pressure Media | PPC shall operate with Nitrogen as the working gas. |
| 5.1 | Operators Manual | Each system shall include an Operators Manual for the PPC and proposed modules with measurement transducers shall be provided with the following information at a minimum: 5.1.1 Setup/installation and operating instructions. 5.1.2 Safety information to prevent injury to personnel and damage to the PPC/Chassis, transducers and associated hardware. Shall contain appropriate warnings, cautions and notes. |
| 5.2 | Maintenance Manual | Each system shall include a Maintenance Manual for the PPC and proposed modules with measurement transducers shall be provided with the following information at a minimum: 5.2.1 Instructions for conducting performance checks and adjustments during recalibration. 5.2.2 Complete peripheral automation command set (see 3.5). 5.2.3 Troubleshooting, maintenance and repair instructions (see 5.2.4 below). 5.2.4 Parts breakdown of PPC/Chassis and Modules with measurement transducers with part number, CAGE code, and OEM listed for replaceable/repairable parts such as circuit cards, switches, displays, fuses, power supply, etc. |
| 5.3 | Provisioning | For parts ordered for maintenance or repair, a data sheet consisting of picture/drawing, dimensions, weight, CAGE code, OEM and cost shall be provided. |
| 6.1 | Training | Instructor and Key Personnel Training: One time training at Redstone Arsenal for up to 10 personnel consisting of general concepts of operation, safety, setup, operation, calibration, adjustment, maintenance, fault isolation and repair. |
| 7.1 | Warranty | Each system shall include a warranty of no less than 2 years. |